Full Access

General Orthopaedics

PATIENT SATISFACTION, FUNCTIONAL OUTCOMES AND SURVIVORSHIP IN PATIENTS WITH A CUSTOMIZED POSTERIOR-STABILIZED TOTAL KNEE ARTHROPLASTY

International Society for Technology in Arthroplasty (ISTA) 31st Annual Congress, London, England, October 2018. Part 1.



Abstract

Background

In this study, we assessed implant survivorship, patient satisfaction, and patient-reported functional outcomes at two years for patients implanted with a customized, posterior stabilized knee replacement system.

Methods

Ninety-three patients (100 knees) with the customized PS TKR were enrolled at two centers. Patients’ length of hospitalization and preoperative pain intensity were assessed. At a single time point follow-up, we assessed patient reported outcomes utilizing the KOOS Jr., satisfaction rates, implant survivorship, patients’ perception of their knee and their overall preference between the two knees, if they had their contralateral knee replaced with an off-the-shelf (OTS) implant.

Results

At an average of 1.9-years implant survivorship was found to be 100%. From pre-op until time of follow-up, we observed an average decrease of 5.4 on the numeric pain rating scale. Satisfaction rate was found to be high with 90% of patients being satisfied or very satisfied and 88% of patients reporting a “natural” perception of their knee some or all the time. Patients with bilateral implants mostly (12/15) stated that they preferred their customized implant over the standard TKR. The evaluation of KOOS Jr. showed an average score of 90 at the time of the follow up.

Conclusion

Based on our results, we believe that the customized PS implant provides patients with excellent outcomes post-surgery. Moreover, a subset of patients with an OTS implant in one knee and a customized PS implant in the other, we observed a trend in patients preferring the customized PS device over their OTS counterparts.