Advertisement for orthosearch.org.uk
Results 1 - 100 of 250
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 660 - 665
1 Nov 1984
Ogilvie-Harris D Jackson R

Three hundred and nineteen patients who had chondromalacia patellae and persistent patellofemoral pain after six months of conservative management underwent arthroscopy and arthroscopic surgery. The results in four aetiological groups were reviewed at one year and five years after operation. Morbidity was minimal. Lavage produced early remission in all groups. Shaving offered a particular advantage in the post-traumatic group. Lateral release plus shaving and lavage was beneficial in the group with maltracking patellae and in half of the idiopathic group. In the group with unstable patellae, lateral release produced good results in only one in four patients. In conclusion, we consider that arthroscopic surgery has a useful role to play in the management of chondromalacia patellae


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 3 | Pages 495 - 501
1 Aug 1967
Crooks LM

1. It is suggested that abruptness of the condylar ridges on the femur plays a major role in the etiology of chondromalacia patellae. The medial condylar ridge is always abrupt in these cases, and indeed in many knees with no evidence of chondromalacia patellae. The lateral condylar ridge is rarely abrupt. 2. The short-term results of forty operations for reduction of femoral ridges in thirty-eight patients, with preservation of the patella in thirty-two cases, are satisfactory


Bone & Joint Research
Vol. 1, Issue 8 | Pages 167 - 173
1 Aug 2012
Jack CM Rajaratnam SS Khan HO Keast-Butler O Butler-Manuel PA Heatley FW

Objectives. To assess the effectiveness of a modified tibial tubercle osteotomy as a treatment for arthroscopically diagnosed chondromalacia patellae. Methods. A total of 47 consecutive patients (51 knees) with arthroscopically proven chondromalacia, who had failed conservative management, underwent a modified Fulkerson tibial tubercle osteotomy. The mean age was 34.4 years (19.6 to 52.2). Pre-operatively, none of the patients exhibited signs of patellar maltracking or instability in association with their anterior knee pain. The minimum follow-up for the study was five years (mean 72.6 months (62 to 118)), with only one patient lost to follow-up. Results. A total of 50 knees were reviewed. At final follow-up, the Kujala knee score improved from 39.2 (12 to 63) pre-operatively to 57.7 (16 to 89) post-operatively (p < 0.001). The visual analogue pain score improved from 7.8 (4 to 10) pre-operatively to 5.0 (0 to 10) post-operatively. Overall patient satisfaction with good or excellent results was 72%. Patients with the lowest pre-operative Kujala score benefitted the most. Older patients benefited less than younger ones. The outcome was independent of the grade of chondromalacia. Six patients required screw removal. There were no major complications. Conclusions. We conclude that this modification of the Fulkerson procedure is a safe and useful operation to treat anterior knee pain in well aligned patellofemoral joints due to chondromalacia patellae in adults, when conservative measures have failed


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 569 - 572
1 Aug 1962
Hodkinson HM

1. The occurrence of bilateral double-layer patellae in association with multiple epiphysial dysplasia is described in three siblings. 2. Twelve cases of bilateral double-layer patellae have been reported previously, and in all there was an accompanying skeletal dystrophy which, although not diagnosed as such, is likely to have been multiple epiphysial dysplasia. 3. It is suggested that although they occur only in a minority of cases, double-layer patellae when present are a feature of considerable diagnostic value in multiple epiphysial dysplasia. Lateral radiography of the knees may therefore be of assistance in the diagnosis of multiple epiphysial dysplasia


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 769 - 774
1 Nov 1985
Bentley G

Full thickness samples of articular cartilage were removed from areas of chondromalacia on the medial and "odd" facets of the patellae of 21 adults and examined by histology, autoradiography and electron microscopy. Surface fibrillation, loss of superficial matrix staining and reduced 35SO4 labelling was seen, with little change in the deep zone. Ten cases showed "fibrous metaplasia" of the superficial cartilage with definite evidence of cell division and apparent smoothing of the surface. Scattered chondrocyte replication appeared to occur in the surrounding intact cartilage. The findings suggest that early lesions in chondromalacia patellae may heal either by cartilage or fibrous metaplasia and that this may account for the resolution of clinical symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 58 - 63
1 Feb 1977
Edwards D Bentley G

Six cases of osteochondritis dissecans patellae have been studied in five patients in an attempt to clarify the aetiology and prognosis. Assessment of the results of treatment was performed using a standard protocol. The thirty-four previous case reports in the literature are reviewed. In four of the five patients symptoms began after flexing the knee under load and three showed patellar subluxation on tangential radiographs. Thus, repetitive shearing stress on the patellar surface is thought to be an important aetiological factor. The indication for operation is a loose osteochondral fragment either wholly or partly detached from the articular surface of the patella. Vertical excision of the affected area of articular cartilage with drilling of the underlying bone gave two "good" and two "excellent" results. Healing of the drilled area and maintenance of the cartilage space was seen in radiographs of all four cases so treated. This simple method of treatment, which probably causes filling of the defect in the surface by fibrocartilage, is recommended


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 74 - 81
1 Feb 1978
Bentley G

Four methods of surgical treatment of chondromalacia patellae have been evaluated after periods ranging from two to thirty years (average seven years), to discover the success rate, complications and indications for each. A total of 140 operations had been performed in 98 patients. Overall, satisfactory results were achieved in 25 per cent after forty shavings of the patellar cartilage, 35 per cent after twenty cartilage excisions and drilling of the subchondral bone, 60 per cent after twenty medial transfers of the patellar tendon and 77 per cent after sixty patellectomies. Thirty-four primary patellectomies gave 82 per cent satisfactory results compared with 62 per cent after twenty-six patellectomies performed after a previously unsuccessful operation. The results were worst in patients below twenty years of age especially women and in those with Grade IV changes in the patellar cartilage. Weakness of the quadriceps after any procedure predisposed to an unsatisfactory result. Extensive late radiological degenerative changes in the knee were not seen. On the basis of the results in this report, patellar tendon transfer is recommended in adolescents and athletes with Grade I, II or III changes in the patellar cartilage. In adults over twenty years of age with Grade I and II changes cartilage excision and drilling is satisfactory. In adults with Grade III and adults or adolescents with Grade IV changes patellectomy is the treatment of choice


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 2 | Pages 179 - 190
1 May 1964
Outerbridge RE

1 . Current theories of the etiology of chondromalacia patellae do not explain satisfactorily either its great frequency or its common site of origin on the medial patellar facet. 2. The etiology can be more logically explained by the presence of a ridge on the upper anterior border of the cartilage of the medial femoral condyle, in most knees. This ridge, consisting of cartilage, or cartilage and bone, varies considerably in height and, in normal knee joint movement, causes considerable friction on the medial patellar facet. 3. The degenerative changes were found to be greater in the presence of the larger ridges, and–because of longer wear and tear–in the older patients. 4. This study indicates that chondromalacia was more severe in women than in men, and in patients overweight. Although the activity of the individual and the power of the quadriceps mechanism must play an extremely important part in this condition, it was not possible to assess this. 5. Two factors previously considered to be important in the etiology of this condition, namely, the length of the patellar tendon and Wiberg's Type III patellar shape, have not been confirmed in this study. 6. Resulting from the present investigation certain precautions are suggested in rehabilitation after operations on the knee, and a surgical method for discouraging the progress of this common, and sometimes disabling, condition has been devised


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 297 - 300
1 Mar 1986
Dowd G Bentley G

Minor degrees of malalignment of the patella and anatomical abnormalities including a flattened sulcus angle and an increased ratio between patellar tendon length and patellar length (PT:P) have been suggested as predisposing factors in the causation of chondromalacia patellae, as well as patellar instability. In order to confirm or refute this hypothesis a prospective study has been performed comparing the congruence and sulcus angles and the PT:P ratio in a group of 35 patients with chondromalacia confirmed by arthroscopy and a group of 33 patients with instability, with those of a group of 50 knees in normal volunteers. While there was a statistically significant correlation between an increased sulcus and congruence angle and a high-riding patella in patients with instability, no correlation could be identified in patients with idiopathic chondromalacia


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 435 - 442
1 Nov 1979
Sikorski J Peters J Watt I

A new radiological technique is presented in which serial axial radiographs of the patellofemoral joints are taken under conditions in which the muscles about the knee and hip are contracted in a manner similar to that during weight-bearing. A form of analysis has been developed whereby patellar rotation can be measured in two planes and femoral rotation about its long axis inferred. A population of asymptomatic adults and children was investigated in this way and their results (regarded as normal) compared with those in fifteen children with idiopathic chondromalacia patellae. In the normal child the femur rotates medially with the onset of muscle activity; by contrast the children with chondromalacia show a reversal of this mechanism


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims

This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates.

Methods

A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1235 - 1238
1 Dec 2023
Kader DF Jones S Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 4 | Pages 752 - 757
1 Nov 1961
Outerbridge RE

1. Chondromalacia of the patella starts most frequently on the medial facet.

2. The anatomy of the medial femoral condyle is described, including the rim at its superior border, and the different arrangement at the upper border of the lateral femoral condyle.

3. Rubbing of the medial patellar facet on the rim at the upper border of the medial femoral condyle can explain in part the etiology of chondromalacia.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 202 - 205
1 Apr 1982
Osborne A Fulford P


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 205 - 210
1 May 1978
Abernethy P Townsend P Rose R Radin E

The articular cartilage of the patella was studied in 100 knees at necropsy. In twenty-one of these knees the cartilage changes were related to the trabecular architecture of the underlying bone. It would appear that the initiation and location of cartilage damage and its rate and degree of progression are related to the relative stiffness of the underlying cancellous bone. On the basis of our observations we suggest that the diagnosis "chondromalacia of the patella" should be reserved for patients with asymptomatic or transiently symptomatic fibrillation of the articular cartilage of the central medial patellar facet. Those patients with persistent patellofemoral pain should be considered to have some other syndrome.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 158 - 158
1 Mar 2008
Boldt DJ Keblish P Munzinger U
Full Access

The purpose of this prospective and randomized study was to objectively evaluate isokinetic strength, clinical, and radiographical outcome in bilateral TKA using the same prosthesis with and without patella resurfacing.

Bilateral TKA, one with, one without patella resurfacing was performed in 22 osteoarthritic patients, mean age was 68 years using the Low-Contact-Stress prosthesis. Minimum Follow-up was one year. Evaluation included clinical investigation, specific patella scores, radiographic analysis and isokinetic strength measurement of both knee flexion and extension at 60 degrees per second (Biodex). surement at 60 degrees per second (Biodex).

There was no significant clinical score difference, but mean isokinetic strength of knee extension was significantly (p< .0001) stronger in the non-resurfaced patella TKA (40.5 Nm) compared with the resurfaced TKA (38,5 Nm). Flexion was also significantly stronger in the patella non-resurfaced group with 22.4 Nm versus 19.5 Nm in the resurfaced group. Mean lateral deviation was significantly (p< .001) less ideal in the resurfaced group as was postoperative patellofemoral congruent contact (p< .001). However, there was no correlation between lateral patella deviation or congruent contact and iso-kinetic strength.

The results of this study indicate that mean isokinetic strength of both knee flexion and extension was significantly stronger in the non-resurfaced patella TKA. This study provides encouraging data for patella non-resurfacing. However, clinical scores or patient’s preference did not show any difference.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 291 - 299
1 Aug 1976
Goodfellow J Hungerford D Woods C

Two distinct lesions affect the articular cartilage of the patella. Surface degeneration occurs particularly on the odd facet; it is age dependent, often present in youth and it becomes more frequent with increasing age. It probably does not occasion patello-femoral pain in youth, but may predispose to degenerative arthritis in that joint in later years and is regarded as a consequence of habitual disuse. The term "basal degeneration" is used to describe a lesion in which there is a fasciculation of collagen in the middle and deep zones of cartilage without, at first, affecting the surface. It was found astride the ridge separating the medial from the odd facet in twenty-three adolescents who had complained of prolonged patello-femoral pain. They were treated by excision of the disc of affected cartilage, with relief of pain in most cases. The pathogenesis of basal degeneration is related to the functional anatomy of the patella.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 832 - 833
1 Sep 1995
Sandhu P Broughton N Menelaus M


Full Access

Lateralisation of the tuberosity tibia causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking patella (LTP), resulting in anterior knee pain, or objective patellar instability (OPI), resulting in recurrent luxations. For a precise preoperative diagnosis the tuberositas tibia (TT) trochlear groove (TG) distance was measured on a CT scan. A distance of more than 15 mm was considered to be pathological.

In a prospective study, the clinical results of a subtle, CT-guided medial tuberosity transfer for LTP and OPI were evaluated. 30 Consecutive patients with LTP and 30 patients with OPI and an increased TT TG were included. Outcomes were documented at 3, 12 and 24 months follow-up using the Lysholm scale, the Kujala score, and a visual analogue pain score. Postoperatively all but one patient reported good improvement in stability (no persistent subluxations or luxations). All patients had a marked improvement in pain and functional scores at follow up. Complications seem to be related to the peroperative technique. CT-guided TT transfer appears to be satisfactory and safe method for treating patients with an increased TT TG leading to either LTP or OPI.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 31 - 31
17 Nov 2023
Warren J Cowie R Jennings L Wilcox R Fermor H
Full Access

Abstract. Objectives. The aim of this study was to develop an in vitro GAG-depleted patella model and assess the biomechanical effects following treatment with a SAP:CS self-assembling hydrogel. Methods. Porcine patellae (4–6 month old) were harvested and subject to 0.1% (w/v) sodium dodecyl sulfate (SDS) washes to remove GAGs from the cartilage. Patellae were GAG depleted and then treated by injection with SAP (∼ 6 mM) and CS (10 mg) in Ringer's solution through a 30G needle. Native, GAG depleted and SAP:CS treated patellae were tested through static indentation testing, using 15g load, 5mm indenter over 1hr period. The degree of deformation of each group was assessed and compared (Mann-Whitney, p<0.05). Native, GAG depleted, sham (saline only) and SAP:CS treated paired patellae and femurs were additionally characterized tribologically through sequential wear testing when undergoing a walking gait profile (n=6 per group). The cartilage surfaces were assessed and compared (Mann-Whitney, p<0.05) using the ICRS scoring system, surface damage was illustrated through the application of Indian ink. Results. Static indentation tests indicated significant increase in indentation deformation of GAG depleted group compared to native group (n=6, p<0.01) and significant reduction in deformation of SAP:CS treated group compared to GAG depleted group (n=6, p<0.05). Sequential wear tests indicated a significant increase in the cartilage damage on the both surfaces of the patellofemoral joint in the GAG depleted group, compared to the native group (n=6, p<0.001), Following SAP:CS treatment, significant protection from damage was observed on femoral surface (n=6, p<0.005), with some non-significant reduction in damage on the patella surface. Sham injections showed no significant increase in damage compared to the native and treated samples. Conclusions. The ∼50% reduction of GAGs represented a moderate osteoarthritic patella cartilage model. This same loss transferred to the dynamic wear tests with significant changes in the damage on the femoral counter face associated with the GAG loss. SAP:CS treatment showed promise in restoring cartilage stiffness to treat Chondromalacia patella in static indentation tests. Sequential wear tests showed that the SAP:CS treatment protects the cartilage layer of both surfaces in the patellofemoral joint from damage in an extreme degeneration model. The sham injections showed that injecting cartilage with a 30G and saline does not cause any significant damage to the cartilage layer. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 63 - 63
1 Feb 2020
Darwish O Langhorn J Van Citters D Metcalfe A
Full Access

Introduction. Patella implant research is often overlooked despite its importance as the third compartment in a total knee replacement. Wear and fracture of resurfaced patellae can lead to implant failure and revision surgeries. New simulation techniques have been developed to analyze the performance of patella designs as they interact with the trochlear groove in total knee components, and clinical validation is sought to ensure that these simulations are appropriate. The objective of this work was to subject several patellar designs to patient-derived deep knee bend (DKB) inputs on a 6 degree of freedom (DOF) simulator and compare the resultant wear scars to clinical retrievals. Materials and Methods. Previously reported DKB profiles were developed based on in vivo patellofemoral data and include a wide range of patient variability. The profiles chosen for this body of work were based on the stress in the patellar lateral facet; maximizing this stress whilst maintaining the ability to run the profile stably on the simulator. Load/kinematic profiles were run on three patellar designs (n=3 per group) for 220,000 cycles at 0.8Hz on an AMTI VIVO joint simulator. A comparison cohort of clinically retrieved devices of the same design was identified in an IRB-approved database. Exclusion criteria included gross delamination, cracking secondary to oxidation, and surgeon-reported evidence of malalignment leading to mal-tracking. 29 Patellae were included for analysis: PFC. ®. All Poly (n=14), ATTUNE. ®. Anatomic (n=6), and ATTUNE. ®. Medialized Dome (n=9). Mean in vivo duration was 70.1 months. Patellae were analyzed under optical microscope in large-depth-of-field mode to map the surface damage profile. Burnishing ‘heat-maps’ were generated for retrievals and simulated patellae by normalizing the patellar size and overlaying silhouettes from each component of the same type using a custom-developed MatLAB code. Results. Burnishing heat-map comparisons between retrievals and simulator specimens for each of the three designs were compared. Retrievals show more variation than simulator devices, however the general loci and relative area of burnished regions is closely aligned for each of the three designs. The retrieved and simulated burnishing scar heat-maps on all-poly PFC. ®. patellae are centered medio-laterally with a wider profile on the lateral aspect. The burnishing marks are continuous. A similar observation may be made of the ATTUNE. ®. medialized dome, retrievals and simulator specimens, though the contact areas appear to be more concentrated away from the apex. The anatomic patellae show two primary regions of contact, and minimal burnishing at the apex. The simulator specimens likewise show two principal regions of contact. Discussion. Wear scar analysis shows that joint simulation on AMTI VIVO yields clinically relevant wear patterns across a variety of device types. Clinically relevant damage provides insight that load and motion inputs to the simulator deliver results that may be used to interpret in vivo performance or analyze future designs and/or materials. This qualitative surface contact analysis will help to inform future quantitative mass loss and fatigue failure studies. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 47 - 47
1 Dec 2021
Kayode O Day G Wijayathunga N Mengoni M Wilcox R
Full Access

Abstract. Introduction. Osteoarthritis (OA) is one of the lead causes of pain and disability in adults. Bone marrow lesions (BMLs) are one feature of subchondral bone involvement in OA. MRI images suggest changes in tissue content and properties in the affected regions however, it is not known if this alters the mechanical behavior of the bone, which could in turn affect OA progression. The aim of this study was to characterize the mechanical properties of BMLs, using a combined experimental and computational approach. Methods. Six human cadaveric patellae from donors aged 56–76 were used in this study; all exhibited BML regions under MRI. Bone plugs were taken from non-BML (n = 6) and BML (n = 7) regions within the patellae, with guidance from the MRI. The plugs were imaged at 82µm resolution using micro computed tomography (µCT) and tested under uniaxial compression. Finite element (FE) models were created for each plug from the µCT scans and morphological properties such as bone volume fraction (BV/TV) were also determined. The relationship between bone volume fraction and apparent modulus was investigated for both sample groups. Results. The BV/TV range was similar for the BML and non-BML groups (0.25–0.46 and 0.18–0.44) From the experimental tests, a moderate positive correlation was found between BV/TV and apparent modulus in the no BML group (r= 0.57) while no correlation was found in the BML group (r = −0.02). From the FE results, a different relationship between BV/TV and element elastic modulus was found for the BML and non-BML groups. Conclusions. The results of this study show that in regions of bone containing BMLs, bone volume fraction does not predict overall apparent modulus and has different relationship to local modulus, suggesting the BML associated tissue structural changes affect mechanical behavior. Funders: EPSRC


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 28 - 28
1 Mar 2021
Amado I Mathavan N Cavanagh B Murphy C Kennedy O
Full Access

Osteoarthritis (OA) is a disease that affects both bone and cartilage. Typically, this disease leads to cartilage degradation and subchondral bone sclerosis but the link between the two is unknown. Also, while OA was traditionally thought of as non-inflammatory condition, it now seems that low levels of inflammation may be involved in the link between these responses. This is particularly relevant in the case of Post-Traumatic OA (PTOA), where an initial phase of synovial inflammation occurs after injury. The inflammatory mediator interleukin 1 beta (IL-1B) is central to this response and contributes to cartilage degradation. However, whether there is a secondary effect of this mediator on subchondral bone, via bone-cartilage crosstalk, is not known. To address this question, we developed a novel patellar explant model, to study bone cartilage crosstalk which may be more suitable than commonly used femoral head explants. The specific aim of this study was to validate this novel patellar explant model by using IL-1B to stimulate the inflammatory response after joint injury and the subsequent development of PTOA. Female Sprague Dawley rats (n=48) were used to obtain patellar explants, under an institutional ethical approval license. Patellae were maintained in high glucose media, under sterile culture conditions, with or without IL-1B (10ng/ml), for 7 days. Contralateral patellae served as controls. One group (n= 12) of patellae were assessed for active metabolism, using two both Live and Dead (L/D) staining and an Alamar Blue assay (AB). A second group (n=12) was used for tissue specific biochemical assays for both bone (Alkaline Phosphatase) and cartilage (sulfated proteoglycan and glycosaminoglycan (sGaG)). Finally, a third group (n=28) of explants were used for histologically analysis. Samples were decalcified, embedded in paraffin and sectioned to 7µm thickness, and then stained using H&E; and Safranin O with fast green. Additionally, toluidine blue and alkaline phosphatase staining were also performed. Our results demonstrate that our system can maintain good explant viability for at least 7 days, but that IL-1B reduces cell viability in patellar cartilage, as measured by both L/D and AB assays after 0, 2, 4 and 7 days in culture. In contrast, sGaG content in cartilage were increased by this treatment. Additionally, ALP, a marker of osteoblastic activity, was increased in IL-1B treated group 4 and 7 days, but was also showed some increase in control groups. Histological analyses showed that IL-1B treatment resulted in reduced proteoglycan staining, demonstrating the powerful effect of this factor in injury response over time. Thus, we conclude that IL-1B affects both bone and cartilage tissues independently in this system, which may have relevance in understanding bone-cartilage crosstalk after injury and how this is involved in PTOA development


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 7 - 7
1 Apr 2018
Cowie R Briscoe A Fisher J Jennings L
Full Access

Introduction. Experimental wear simulation of an all-polymer knee implant has shown an equivalent rate of wear of UHMWPE tibial components against PEEK-OPTIMA™ and cobalt chrome femoral components of a similar initial geometry and surface topography. However, when the patella is resurfaced with an UHMWPE patella button, it is important to also ascertain the wear of the patella. Wear debris from the patella contributes to the total volume of wear debris produced by the implant which should be minimised to reduce the potential for osteolysis and subsequent implant loosening. The aim of this study was to investigate the wear of the patellofemoral joint in an all-polymer knee implant. The wear of UHMWPE patellae articulating against PEEK-OPTIMA™ femoral components was compared to UHMWPE articulating against cobalt chrome femoral components. Materials and Methods. Six mid-size (size C) PEEK-OPTIMA™ femoral components (Invibio Knee Ltd., UK) and six cobalt chrome femoral components of similar initial surface topography and geometry were coupled with 28mm all-polyethylene GUR1020 patellae (conventional, EO sterile) (Maxx Orthopaedics, USA). The implants were set up in a ProSim 6 station electromechanical knee simulator (Simulation Solutions, UK) which was modified for testing the patellofemoral joint. 3 million cycles (MC) of wear simulation was carried out under kinematics aiming to replicate a gait cycle adapted for an electromechanical simulator from previous work by Maiti et al. The simulator used has six degrees of freedom of which four were controlled; axial force up to 1200N, flexion/extension 22°, superior-inferior (SI) displacement (22mm) and Abduction-adduction (AA) (4°). The SI and AA were displacement controlled and driven through the patella. The medial-lateral displacement and tilt (internal/external rotation) of the patella were passive so the patella button was free to track the trochlear groove. The lubricant used was 25% bovine serum supplemented with 0.03% sodium azide to retard bacterial growth. The wear of patellae was determined gravimetrically with unloaded soak controls used to compensate for the uptake of moisture by the UHMWPE. The mean wear rate ± 95% confidence limits were calculated and statistical analysis was carried out using ANOVA with significance taken at p<0.05. Results. The mean wear rates of the UHMWPE patellae were 0.26±0.21 mm. 3. /MC and 0.35±0.17 mm. 3. /MC against PEEK-OPTIMA™ and cobalt chrome femoral components respectively. There was no significant difference in wear rate against the different femoral component materials (P=0.38). Against both femoral component materials, a ‘bow tie’ shaped wear scar was evident on the patellae typical of that seen in retrieval studies and reported in previous experimental wear simulation of the patellofemoral joint. Conclusion. The wear rate of the UHMWPE patellae was low against both PEEK-OPTIMA™ and cobalt chrome femoral components and comparable to previous work by Vanbiervliet et al. This study further shows that in terms of its wear performance, PEEK-OPTIMA™ has promise as an alternative bearing material to cobalt chrome in the femoral component of total knee replacements


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 78 - 78
1 Mar 2021
Kandhari V Grasso S Twiggs J
Full Access

Abstract. Background. Accurate analysis of the patellar resurfacing is essential to better understand the etiology of patella-femoral problems and dissatisfaction following total knee arthroplasty (TKA). In the current published literature patellar resurfacing is analysed using 2D radiographs. With use of radiographs there is potential for error due to differences in limb positioning, projection, anatomic variability and difficulties in appreciating the cement-bone interface. So, we have developed a CT Scan based 3D modelled technique for accurate evaluation of patellar resurfacing. Methods. This technique for analyses of patellar resurfacing is based on the pre-operative and pos-operative CT Scan data of the patients who underwent TKA with patellar resurfacing. In the first step, accurately landmarked 3D models of pre-op patellae were created from pre-operative CT Scan data in ScanIP software. This model was imported in Geomagic design software and computational model of post-op patella was created. This was further analysed to determine the inclination of the patellar resection plane, patellar button positioning and articular volumetric restoration of the patella. Reliability and reproducibility of the technique was tested by comparing 3 sets of 10 measurements done by 2 independent investigators on 30 computational models of patellae derived from the data of randomly chosen 30 TKA patients. Results. The developed technique for analyses of patellar resurfacing is reliable and reproducible. The intraclass correlation co-efficient was >0.90 for the 10 measurements performed by two investigators. Conclusions. This technique can be used by surgeons and engineers for accurate analysis of the patellar resurfacing especially in patients with persistent patello-femoral problems after TKA. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 26 - 26
1 Nov 2021
Amado I Hodgkinson T Murphy C Kennedy O
Full Access

Introduction and Objective. Traditionally, osteoarthritis (OA) has been associated mostly with degradation of cartilage only. More recently, it has been established that other joint tissues, in particular bone, are also centrally involved. However, the link between these two tissues remains unclear. This relationship is particularly evident in post-traumatic OA (PTOA), where bone marrow lesions (BMLs), as well as fluctuating levels of inflammation, are present long before cartilage degradation begins. The process of bone-cartilage crosstalk has been challenging to study due to its multi-tissue complexity. Thus, the use of explant model systems have been crucial in advancing our knowledge. Thus, we developed a novel patellar explant model, to study bone cartilage crosstalk, in particular related to subchondral bone damage, as an alternative to traditional femoral head explants or cylindrical core specimens. The commonly used osteochondral explant models are limited, for our application, since they involve bone damage during harvest. The specifics aim of this study was to validate this novel patellar explant model by using IL-1B to stimulate the inflammatory response and mechanical stimulation to determine the subsequent developments of PTOA. Materials and Methods. Lewis rats (n=48) were used to obtain patellar and femoral head explants which were harvested under an institutional ethical approval license. Explants were maintained in high glucose media (containing supplements), under sterile culture conditions. Initially, we characterised undamaged patellar explants and compared them with the commonly used femoral head. First, tissue viability was assessed using an assay of metabolic activity and cell damage. Second, we created chemical and mechanical damage in the form of IL-1B treatment, and mechanical stimulation, to replicate damage. Standard biochemical assays, histological assays and microstructural assays were used to evaluate responses. For chemical damage, explants were exposed to 10ng/ml of IL-1B for 24 hours at 0, 1, 3 and 7 days after harvesting. For mechanical damage, tissues were exposed to mechanical compression at 0.5 Hz, 10 % strain for 10 cycles, for 7 days. Contralateral patellae served as controls. In both groups, sGAG, ADAMTS4, and MMP-13 were measured as an assessment of representative cartilage responses while ALP, TRAP and CTSK were assessed as a representative of bone responses. In addition to this, histomorphometric, and immunohistochemical, evaluations of each explant system were also carried out. Results. Our results confirm that the patellar explant system is an excellent ex vivo model system to study bone-cartilage crosstalk, and one which does not induce any bone damage at the time of tissue harvest. We successfully established culture conditions to maintain viability in these explants for up to 28 days. Rat IL-1B treatment resulted in increased both proteoglycan content and bone metabolism markers after 7 days when compared with the controls. To confirm this finding, qualitative immunohistochemical staining showed chondrocytes increased expression of MMP13 after treatment with IL-1B. Furthermore, we observed that the levels of ADAMTS4 decreased in 48 hours after IL-1B exposure. Contrastingly IL-1B treatment had the opposite effect on CTSK markers when compared with the control. Mechanically compressed patellae showed a decrease in compressive moduli from day 3 to day 7, suggesting that tissue remodelling may have taken place as a compensatory mechanism in response to damage. In addition, MMP13 release decreased over 48 hours after mechanical compression, while TRAP levels were increased compared with the control. Conclusions. Thus, we successfully demonstrated that IL-1B and mechanical stimulation affects both bone and cartilage tissues independently in this system, which may have relevance in the understanding of bone-cartilage crosstalk after injury and how this is involved in PTOA development


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 29 - 29
1 May 2016
Harris S Iranpour F Riyat H Cobb J
Full Access

Introduction. The trochlea of a typical patellofemoral replacement or anterior flange of a total knee replacement usually extends past the natural trochlea and continues onto the femoral anterior cortex. One reason for this is that it allows a simple patella button to be permanently engaged in the trochlea groove in an attempt to ensure stability. On the natural patella, the apex helps to guide it into the trochlea groove as the knee moves from full extension into flexion. The aim is to study whether a generalised patella can be created that is close in form to a healthy patella. Method. MRI scans were taken of 30 patellae. Characteristics of these patellae (height, width, thickness, apex angle) were measured. The apex angle was found to be similar between patellae (mean=126 degrees, sd = 8.8), as were the ratios between height and width (mean width/height = 1.05, sd = 0.07) and between thickness and width (mean width/thickness = 1.8, sd = 0.19). These patellae were then segmented to create a surface including cartilage, resulting in 30 STL (stereolithography) files in which the surfaces are represented by triangle meshes. To design the average patella the individual patellae were aligned to a standard frame of reference by placing a set of landmarks on the proximal/distal, medial/lateral and anterior/posterior extents of each (fig.1). The vertical axis was defined as passing parallel to the proximal/distal points and the horizontal as passing parallel to the medial/lateral points when looking along the computed vertical axis. The origin centre of the frame of reference was chosen to be mid-way between these points. The mean width was then computed and each patella scaled linearly around the origin to give them all equal width. All the aligned patellae were then averaged together to provide a composite cartilaginous patella. The averaging process was achieved by taking one patella as a seed. The patella chosen for seed was that whose parameters were closest to the average width, height and thickness. An approximately normal vector was passed a point ‘P’ on the seeds, and the points at which these intersected the other models were then determined. The closest intersection point to ‘P’ on each model was chosen and these averaged together. ‘P’ is then replaced in the model with this average point. The averaging process then continues with all the remaining points on the seed model in the same manner to build the average models. Results and Discussion. The mean patella was compared with individual patellae. This comparison was performed by taking each point on the mean patella and finding the closest point on individual patellae - a colour coded map of differences was obtained (fig.2) along with a mean of the absolute difference for each patella. The absolute mean difference ranged from 0.56mm to 1.33mm, averaging at 0.85mm. This shows a reasonable fit between the average patella and each individual example, raising the possibility of using the average shape in future research to develop anatomical patellofemoral replacements and for planning patella resurfacing


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 18 - 18
23 Feb 2023
Grant M Zeng N Lin M Farrington W Walker M Bayan A Elliot R Van Rooyen R Sharp R Young S
Full Access

Joint registries suggest a downward trend in the use of uncemented Total Knee Replacements (TKR) since 2003, largely related to reports of early failures of uncemented tibial and patella components. Advancements in uncemented design such as trabecular metal may improve outcomes, but there is a scarcity of high-quality data from randomised trials. 319 patients <75 years of age were randomised to either cemented or uncemented TKR implanted using computer navigation. Patellae were resurfaced in all patients. Patient outcome scores, re-operations and radiographic analysis of radiolucent lines were compared. Two year follow up was available for 287 patients (144 cemented vs 143 uncemented). There was no difference in operative time between groups, 73.7 v 71.1 mins (p= 0.08). There were no statistical differences in outcome scores at 2 years, Oxford knee score 42.5 vs 41.8 (p=0.35), International Knee Society 84.6 vs 84.0 (p=0.76), Forgotten Joint Score 66.7 vs 66.4 (p=0.91). There were two revisions, both for infection one in each group (0.33%). 13 cemented and 8 uncemented knees underwent re-operation, the majority of these being manipulation under anaesthetic (85.7%), with no difference (8.3% vs 5.3%, 95% CI -2.81% to 8.89%, p = 0.31). No difference was found in radiographic analysis at 2 years, 1 lucent line was seen in the cemented group and 3 in the uncemented group (0.67% v 2.09%, 95%CI -4.1% to 1.24%, p = 0.29). We found no difference in clinical or radiographic outcomes between cemented and uncemented TKR including routine patella resurfacing at two years. Early results suggest there is no difference between cemented and uncemented TKR at 2 years with reference to survivorship, patient outcomes and radiological parameters


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 35 - 35
1 Jan 2016
Hedley A
Full Access

Introduction. The metal-backed patella was originally designed to address shortcomings found with cemented, all-polyethylene patellae. However, complications relating to an all-polyethylene patella were reported to account for up to half of all knee revisions. At the same time, good fixation with bone ingrowth was observed in both titanium and cobalt chromium porous-coated patellae. The advantages provided by using a metal-backed patella, such as uniform load sharing, decreased polyethylene deformation, and potential for biological fixation, may be unjustly outweighed by the fear of patellar component failure; high rates of failure have not been inherent to all metal-backed patella designs. Over the past decade, we have used a metal-backed patella design with excellent results that may be due largely to the design features of the component. Also, we believe there are certain selection criteria that should be strictly adhered to when implanting metal-backed patellae. Correct selection criteria and improved component design strongly indicate the use of press-fit metal-backed patellae. Methods. This single-center study was designed to conduct clinical and independent radiographic review of primary metal-backed, press-fit patella patients with a minimum five-year follow-up. Potential patients were recruited from a group of existing metal-backed patella patients within the principal investigator's medical practice. All patients recruited for this study were required to have undergone primary knee replacement surgery at least five years prior to clinical and radiographic evaluation. Patients were included if they had a diagnosis of noninflammatory degenerative joint disease. Patients with a BMI >40 were excluded from this study. Radiographic analysis was conducted by an independent reviewer according to the current Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Any radiographs that the reviewer deemed questionable were shown to a second independent orthopaedic surgeon for review, comment, and validation of observations. Kaplan-Meier survivorship was determined for all metal-backed patellae. For survival analysis, only knees with radiographic data were included (74 knees). KSS, WOMAC, and SF-36 scores were calculated also. Results. Seventy-four patients (88 knees) were enrolled in the study, 31 women (41.2%) and 43 men (58.1%). At the time of surgery, the average age was 59.7 years (range, 40–86 years), and the average BMI was 30.6 (range, 19.1–39.6). The breakdown of patients who completed the study and those who were lost to follow-up is shown in Table 1. One metal-backed patella was revised at 49 months for loosening at the bone/implant interface. Survivorship of the metal-backed patellae at minimum five-year follow-up was estimated to be 93.95% with bounds of 73.61% and 98.74%. No radiolucencies greater than 1 mm were observed in any radiographs (Fig. 1), with the exception of the one revision case. Conclusion. Our experience with this metal-backed patella design has been excellent. Failure does not occur due to dissociation of the plastic. As the porous coating is almost under constant compression, biological fixation is assured in most instances, as confirmed by our minimum five-year radiological results. Improved component design and adherence to the correct patient selection criteria absolutely indicate the use of press-fit metal-backed patellae


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 27 - 27
1 May 2019
Gustke K
Full Access

Total knee replacements are being more commonly performed in active younger and obese patients. Fifteen-year survivorship studies demonstrate that cemented total knee replacements have excellent survivorship, with reports of 85 to 97%. Cemented knee arthroplasties are doomed to failure due to loss of cement-bone interlock over time. Inferior survivorship occurs in younger patients and obese patients who would be expected to place increased stress on the bone-cement interfaces. Roentgen stereophotogrammetric analysis (RSA) studies have indicated that cementless fixation should perform better than cemented fixation. However, cementless fixation for total knee replacement has not gained widespread utilization due to the plethora of poor results reported in early series. The poor initial results with cementless total knee replacement have occurred due to poor implant designs such as cobalt chrome porous interfaces, poor initial tibial component stability, lack of continuous porous coating, poor polyethylene, and use of metal-backed patellae. I have used cementless fixation for total knee replacements for young, active, and heavy patients since 1986 when durability over 20 years is desirable. My series of over 1,300 cementless TKAs represents about 20% of the 6,500 total knees I have performed from 1986 to 2017. I have seen initial failures in my series due to the use of metal-backed patellae with thin polyethylene, older generation polyethylene, and use of screws with the tibial components which provide access to the metaphyseal bone for polyethylene wear debris. Overall implant fixation failures were still significantly low due to the use of a highly porous titanium surface on both the tibial and femoral components. With the advent of utilizing implants with continuous porous surfaces and highly crosslinked polyethylene, and elimination of use of metal-backed patellae and tibial screws, I have only had one revision due to aseptic loosening or osteolysis in the last 1,071 cases performed since 2002. Almost 50% of total knees are now performed on patients under the age of 65. A 55-year-old patient has a 30 year life expectancy. Modern total knee replacement design has made biological fixation predictable for young and heavy patients. Because it is a biological interface, it should respond better than cement to the increased stresses that will be applied over many years by our younger, more active and heavier total knee population


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 25 - 25
1 Nov 2016
Gustke K
Full Access

Total knee replacements (TKRs) are being more commonly performed in active younger and obese patients. Fifteen year survivorship studies demonstrate that cemented total knee replacements have excellent survivorship, with reports of 85% to 97%. However, inferior survivorship occurs in younger patients and obese patients who would be expected to place increased stress on the bone cement interfaces. Cementless fixation for total knee replacement has not gained widespread utilization due to the plethora of poor results reported in early series. These poor results do not reflect that cementless fixation is not obtainable, since an almost universal acceptance of cementless fixation for total hip replacement has shown. A Cochrane database study of total knees with roentgen stereophotogrammetric analysis (RSA) demonstrated that the risk of future aseptic loosening should be 50% less with cementless fixation. The poor initial results with cementless total knee replacement have occurred due to poor implant designs such as cobalt chrome porous interfaces, poor initial tibial component fixation, lack of continuous porous coating, poor polyethylene, and use of metal-backed patellae. I have used cementless fixation for total knee replacements for young, active, and heavy patients since 1986 when durability over 20 years is desirable. My series of over 1,000 cementless TKRs represents about 20% of the total knees I have performed from 1986 to 2015. I have seen failures in my series due to the initial use of metal-backed patellae with thin polyethylene and use of screws and femoral and tibial components which provide access to the metaphyseal bone for polyethylene wear debris. Overall failures were still significantly low due to the use of highly porous titanium surfaces on the tibial and femoral components. Isolated aseptic loosening only occurred on one tibial component in my entire series. With the advent of utilizing implants with continuous porous surfaces and highly cross-linked polyethylene, and elimination of use of metal-backed patellae and tibial screws, I have only had one revision due to aseptic loosening or osteolysis in the last 760 cases performed since 2002. Almost 50% of total knees are now performed on patients under the age of 65. A 55-year-old patient has a 30-year life expectancy. Modern total knee replacement design has made biological fixation predictable for young and heavy patients. Because it is a biological interface, it should respond better than cement to the increased stresses that will be applied over many years by our younger, more active and heavier total knee population


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 52 - 52
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 9 - 9
1 Jan 2004
Burroughs B O’Connor D Sargent M Muratoglu O Rubash H Freiberg A Estok D Jasty M Harris W Deluzio K Krevolin J Wyss U Shen M
Full Access

A high proportion of complications following TKR occur at the patellofemoral articulation secondary to delami-nation and adhesive/abrasive wear. Electron beam cross-linking and melting has been shown to substantially reduce delamination and adhesive/abrasive wear in polyethylene tibial inserts. A series of in-vitro patella wear and fatigue tests were developed to explore the benefits of this material at the patellofemoral articulation. Patellae (NKII, Sulzer Orthopedics, Inc., Austin, TX) were tested on an AMTI (Watertown, MA) knee simulator articulating against the trochlear grove of the femoral component. The simulator controlled flexion/ extension and patellofemoral contact force. Each test included patellae manufactured from conventional and electron beam crosslinked and melted polyethylene. Three different simulations were created: i) normal gait (5 million cycles) with optimal component alignment, ii) stair climbing (2 million cycles) with optimal component alignment, iii) stair climbing (2 million cycles) with 4° of femoral component internal rotation to simulate a component malalignment condition. In the last two simulations all patellae were artificially aged for 35 days in 80°C air to simulate one aspect of the long term oxidative state of each material. In normal gait, the unaged conventional and highly cross-linked materials demonstrated similar behaviour. In stair climbing with optimal component alignment, the aged conventional patellae developed cracks by 2 million cycles. In stair climbing with component malalign-ment the aged conventional patellae developed cracks and delamination by 1 million cycles. None of the highly cross-linked components showed cracks or delamination. These results demonstrate the potential advantage of highly cross-linked polyethylene for the patella


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 88 - 88
1 Apr 2017
Barrack R
Full Access

Resurfacing the patella is performed the majority of the time in the United States and in many regions it is considered standard practice. In many countries, however, the patella is left un-resurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine rather more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced patellae underwent surgery while only 2 of 11 non-resurfaced patellae underwent subsequent surgery. More than 3 times as many painful total knees that were referred for evaluation had already had their patella resurfaced. In spite of the fact that approximately equal number of total knees were performed in this area without patella resurfacing, far more patients presented to clinic with painful total knee in which the patella had been resurfaced. The numerous pathologies requiring a treatment following patella resurfacing included patella loosening, fragmentation of the patella, avascular necrosis patella, late stress fracture, lateral facet pain, oblique resurfacing, and too thick of a patellar composite. In a large multi-center randomised clinical trial at 5 years from the United Kingdom in over 1700 knees from 34 centers and 116 surgeons, there was no difference in the Oxford Score, SF-12, EQ-5D, or need for further surgery or complications. The authors concluded, “We see no difference in any score, if there is a difference, it is too small to be of any clinical significance”. In a prospective of randomised clinical trial performed at Tulane University over 20 years ago, no differences were observed in knee score, a functional patella questionnaire, or the incidence of anterior knee pain between resurfaced and un-resurfaced patellae at time intervals of 2–4 years, 5–7 years, or greater than 10 years. Beyond 10 years the knee scores of total knee patients with a resurfaced patella had declined significantly greater than those with a non-resurfaced patella. There are numerous advantages of not resurfacing the patella including less surgical time, less expense, a lower risk of “major” complications (especially late complications), and if symptoms develop in an un-resurfaced patella, it is an easier salvage situation with more options available. A small percentage of total knee patients will be symptomatic whether or not their patella is resurfaced. Not resurfacing the patella retains more options and has fewer complications. The major determinant of clinical result and the presence of anterior knee pain after knee replacement is surgical technique and component design not whether or not the patella is resurfaced. Patella resurfacing is occasionally necessary for patients with inflammatory arthritis, a deformed or maltracking patella, or symptoms and pathology that are virtually restricted to the patellofemoral joint. For the vast majority of patients, however, patella resurfacing is not necessary


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 95 - 95
1 Mar 2006
Harman M Markovich G Banks S Hodge W
Full Access

Introduction: Patellar complications after total knee arthroplasty (TKA) remain a common reason for failure. Fully congruent patellar components, with larger contact areas and a polyethylene articular surface that is free to rotate in the frontal plane (LCS design), were designed to accommodate patellar mechanics and decrease wear. However, it remains to be determined whether the perceived advantages of a mobile-bearing, fully congruent patella design are realized in-vivo. The purpose of this study is correlate wear patterns on congruent mobile-bearing patellar components with patellar mechanics that existed after TKA. Methods: Uncemented metal-backed patellar components were retrieved at revision surgery from 26 knees with meniscal bearing (23 knees) and rotating platform (3 knees) LCS mobile bearing prostheses (DePuy Orthopaedics). Mean patient age and time in-situ was 75+11 years and 11+4 years, respectively. Revision reasons included bearing wear (11), patella wear (7), instability (2), pain (3), loosening (1), osteolysis (1), and unknown (1). Polyethylene damage was assessed using optical microscopy. Articular wear area was measured using digital image analysis and the % area, location and incidence of each damage mode was calculated. Results: The average damage area on the retrieved patella occupied 69%+15% of the surface. Burnishing, delamination and scratching modes occupied the largest areas. Delamination was noted on 58% of the retrieved patellae, predominantly located in the superior-medial quadrant. Nine (35%) patellae were fractured, with the fracture plane typically oriented in the medial-lateral direction or along the lateral edge. Twently one (81%) patellae had subsurface cracks oriented along the superior-inferior axis on the extreme lateral edge and along the medial-lateral axis. None of the patellae had embedded third body debris, but the embedded superior metal pin was exposed due to extreme damage in 4 patellas. The original femoral and tibial components were left in-situ in all knees at the time of revision, such that only the polyethylene tibial and patellar articulations were exchanged. Discussion: Despite severe wear of the components, there was only a 5% incidence of osteolysis noted intra-operatively. Cyclic compressive and tensile forces during knee flexion likely caused initiation and propagation of cracks resulting in patellar bearing fracture. The delami-nation patterns on the retrieved patellae are consistent with bearing rotation into an incongruent bearing position during knee flexion, with presumably high contact stresses occurring in the delaminated superior-medial quadrant. Fully congruent mobile-bearing patella components must maintain mobility between the articular surface and metal back so that areas of incongruent contact, and associated high contact stresses and delamination, do not occur during in-vivo function


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 124 - 124
1 Mar 2010
Rosenstein A Postak PD Greenwald S
Full Access

INTRODUCTION: Following Total Knee Arthroplasties, patellofemoral complications have shown to be responsible for approximately 50% of re-operations. Contemporary patellar designs employ both “onlay” and “inset” configurations. The latter promotes ease of placement, reduced bone removal and a heralded theoretic advantage of increased strength at the fixation interface. However, to date, no reports have compared the disassociation strengths of these two patellar component modes of fixation. The purpose of this study is to quantify the shear disassociation strength for both onlay and inset patellar fixation techniques. METHODS: Two sets of synthetic solid foam patellae were prepared using standard milling techniques for symmetrical, three-peg onlay and inset polyethylene cylinders of identical dimension. The use of synthetic bones in mechanical testing was validated in the past. The cylinders were cemented to the synthetic patellae, using standard cementing techniques. The fixation resistance of both groups was measured using an Instron Testing Machine. A compressive joint force simulating chair rise was applied perpendicular to the anterior surface of the patellar component model. A shearing displacement was then applied to the composite until patellar component disassociation. RESULTS: The mean shear strength of the onlay group was 2540 N SD 236 N, (n=7) and 3180 N SD 186 N, (n=6) for the inset group. The inset patellae was 25% (640 N) stronger than the onlay patellae, (p=0.0002, two-tailed student t-test). DISCUSSION/CONCLUSION: The results of the study demonstrated a significantly higher resistance of inset patellar fixation to shear stress compared to onlay patellar fixation. Although further in-vivo studies are indicated, the data suggests that the use of inset patella in total knee replacements may offer stronger fixation and consequently decreasing morbidity associated with patella implant loosening


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 53 - 53
1 Nov 2016
Barrack R
Full Access

Resurfacing the patella is performed the majority of the time in the US and in many regions it is considered standard practice. In many countries, however, the patella is left unresurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine whether more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced patellae underwent surgery while only 2 of 11 non-resurfaced patellae underwent subsequent surgery. More than 3 times as many painful total knees that were referred for evaluation had already had their patella resurfaced. In spite of the fact that approximately equal number of total knees were performed in this area without patella resurfacing, far more patients presented to clinic with painful total knee in which the patella had been resurfaced. The numerous pathologies requiring a treatment following patella resurfacing included patella loosening, fragmentation of the patella, avascular necrosis patella, late stress fracture, lateral facet pain, oblique resurfacing, and too thick of a patellar composite. In a large multi-center randomised clinical trial at 5 years from the United Kingdom in over 1700 knees from 34 centers and 116 surgeons, there was no difference in the Oxford Score, SF-12, EQ-5D, or need for further surgery or complications. The authors concluded, “We see no difference in any score, if there is a difference, it is too small to be of any clinical significance”. In a prospective randomised clinical trial performed at Tulane University over 20 years ago, no differences were observed in knee score, a functional patella questionnaire, or the incidence of anterior knee pain between resurfaced and unresurfaced patellae at time intervals of 2–4 years, 5–7 years, or greater than 10 years. Beyond 10 years the knee scores of total knee patients with a resurfaced patella had declined significantly greater than those with a non-resurfaced patella. There are numerous advantages of not resurfacing the patella including less surgical time, less expense, a lower risk of “major” complications (especially late complications), and if symptoms develop in an unresurfaced patella, it is an easier salvage situation with more options available. A small percentage of total knee patients will be symptomatic whether or not their patella is resurfaced. Not resurfacing the patella retains more options and has fewer complications. The major determinant of clinical result and the presence of anterior knee pain after knee replacement is surgical technique and component design not whether or not the patella is resurfaced. Patella resurfacing is occasionally necessary for patients with inflammatory arthritis, a deformed or maltracking patella, or symptoms and pathology that are virtually restricted to the patellofemoral joint. For the vast majority of patients, however, patella resurfacing is not necessary


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 457 - 457
1 Sep 2009
Green C Flavin R Fitzpatrick D Moran R
Full Access

Graft choices for revision anterior cruciate ligament (ACL) reconstruction and complex ligament reconstructions of the knee are controversial. The aim of our study was to analyze the biomechanical effect of harvesting bone plugs from both the distal and proximal poles of the patella, to simulate a simultaneous harvesting of a Bone – Patellar Tendon – Bone and Quadriceps Tendon – Bone grafts, in a transverse stress environment. Sixty Bovine Patellae were analysed. They were divided into 4 groups – based on the residual bone bridge (percentage of total length of patella) remaining after bone plug resection. 0 – 10%, 11 – 20%, 21 – 30% and > 30%. All patellae were tested in a modified 4 – point bending environment, to a maximum load of 10,000N, in a customized designed jig. This method simulates the axial bending stress on the patella during knee flexion. All dimensions of the patellae were recorded including Depth of patella at bone resection and wall thickness adjacent to plug resection site. All patellae with a 0% bone bridge fractured (Ultimate Tensile Strength/UTS) at a mean Tensile Force of 5863N (Range 3140 – 8730N). There was a subgroup of incomplete fractures – extra-articular fractures – which fractured at 6542N (Range 5085 – 9180N). The remaining specimens failed to fracture. Comparing the UTS and the patellar dimensions, using Weibull’s Statistical Analysis we demonstrated that less than 60% bone plug resection carried a very low probability of fracture. This study demonstrates the safe criteria for bone – tendon graft harvesting from both the proximal and distal poles of the patella. With regards to a normal human patella, a 40% bone – bridge is approximately a 20mm bone – bridge. We conclude that the simultaneous harvesting of Bone – Patellar Tendon – Bone and Quadriceps Tendon – bone grafts from a patella has no significant increase in the fracture risk of the patella


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 3 - 3
1 Jan 2004
Markel D Klein R Bushelow M Kester M
Full Access

Rotational mal-alignment of the patella-femoral interface will result in increased wear. Highly cross-linked polyethylene will decrease wear even if mal-aligned. A biomechanical model based on high load and flexion was used to measure wear of rotationally aligned and mal-aligned all-polyethylene patellae. The components were articulated against “aligned” and “mal-aligned” (60 internally rotated) femoral components. The patella were subjected to a constant 2224 N force and the femoral components rotated from 600 to 1200 at 1.33 Hz. Patellae of identical geometry made of conventional UHMWPE and highly crosslinked UHMWPE were tested to 1 000 000 cycles. Wear was determined by gravimetric measurement relative to cemented soak controls. Conventional UHMWPE: All samples demonstrated damage (burnishing and scratching) of the articulating surfaces. There was a significant increase in wear (p< .05) in the mal-aligned patella. Highly cross-linked patellae: All components fractured in the mal-aligned construct (gamma irradiated remelted n=6, gamma irradiated and annealed n=2). Failure first occurred at the cement interface then at the posts. Correct femoral rotation is important during TKA. The intertrochlear line, tibial cut, epicondylar axis and posterior condyles are helpful landmarks, but there is still eyeball control of rotation. It is clear from this study that rotational mal-alignment will result in increased polyethylene wear. Highly cross-linked polyethylene has decreased wear in THA. Unfortunately, the decrease in ductility and toughness may make the use of these materials unsuitable for TKA. Based on this study model, patellar components would need to be redesigned if highly cross-linked polyethylene were to be applied. The wear rate of conventional UHMWPE patellae is increased by rotational mal-alignment. Highly cross-linked components were a poor solution to problem. Use of highly cross-linked polyethylene resulted in component fracture


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 444 - 444
1 Apr 2004
Minns RJ Young S Bibb R Moliter P
Full Access

The purpose of this study was to characterise accurately, the extent and geometry, and produce representative rigid resin models of full thickness articular cartilage lesions of various types, shapes and sizes on the articular surface of pig patellae. Ten adult pig patellae and three adult Ox patellae were obtained and cleared of adhering tissue. Full thickness lesions were induced from oval shaped to “U” shaped scarifications by careful use of a hand held bur, and the geometry noted by taking appropriate dimensions with a Vernier cailper in the horizontal and vertical planes, and plan view photographs. MRI images using fat-suppressed weighted 1.5 mm thick slices scans in the horizontal plane, were produced in DICOM format for conversion to SLE files used in the reconstruction in the computer. The patellae were then held in a stone plaster mix to produce a male mould of the articular surface. The computer images were generated and the physical dimensions taken with the Vernier calliper were recorded from the reconstructed image in the computer using graphics software. The computer data was used to produce a rigid full scale model of the articular surface in resin using laser stereolithography which is using in the rapid prototyping industry. The resin models were matched with the male plaster moulds to confirm an accurate match of the 3-dimensional shape of the computer generated in all the types of lesions we produced. It is proposed to use the rigid models to produce sterile templates that could be used by surgeons to fashion an area around a lesion using a suitable reamer/bur using a predetermined criteria of cartilage thickness (say 2 mm), and the same geometrical data would be used to produce a suitable semi rigid scaffold shaped to the lesion. Our study has shown that very accurate 3 dimensional data can be quickly processed from MRI images to produce, using current rapid prototyping techniques, templates and implants to fit lesions accurately in the patella. There is no reason why this technology could not be applied to any joint surface that can be accessed by MRI


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 52 - 52
1 Apr 2018
Huish E Coury J Ummel J Casey J Cohen J
Full Access

Introduction. Management of the patellofemoral surface in total knee arthroplasty (TKA) remains a topic of debate. Incidence of anterior knee pain and incidence of repeat operation have been the focus of several recent meta-analyses, however there is little recent data regarding patients” subjective ability to kneel effectively after TKA. The purpose of this study was to compare patient reported outcomes, including reported ability to kneel, after total knee arthroplasty with and without patellar resurfacing. Methods. Retrospective chart review of 84 consecutive patients who underwent primary TKA with patella resurfacing (56 knees) or without patella resurfacing (28 knees) having a minimum of 2.5 year follow up was performed. Oxford knee scores (OKS), visual analog pain scores (VAS), and questionnaires regarding ability to kneel were evaluated from both groups. Inability to kneel was defined as patients reporting inability or extreme difficulty with kneeling. Shapiro-Wilk test was used to determine normality of data. Mann Whitney U test was used to compare the OKS and VAS between groups. Chi square test was used to compare kneeling ability between groups. Statistical analysis was performed with SPSS version 23 (IBM, Aramonk, NY). Results. The 84 patients included 26 males and 58 females with average age 66.5 (range 46–91). Average follow up was 51 months (range 30–85). There was no significant difference in the percentage of female patients (64% vs 79%), age (67.8 vs 63.8), or reoperation rate (4% vs 7%) between the resurfaced and non-resurfaced groups. There was significantly longer follow up in the non-resurfaced group (57 vs 48 months). There was no statistically significant difference between the resurfacing and non-resurfacing group in terms of OKS (39 vs 38) or VAS (2.5 vs 3.0). However, those patients who did not have their patellofemoral joint resurfaced were more likely to report ability to kneel when compared to the resurfacing group (64% vs 39%, p=0.035). Kneeling ability was not correlated with duration of follow up, patient age or VAS. Kneeling ability was higher in female patients (57%) than males (27%), p=0.017. Discussion. There is concern for increased anterior knee pain and reoperation in patients whose patellae are not resurfaced. However, their failure to imnprove after revision to a resurfaced patella has left some room for depate as to whether or not the lack of resurfacing is the cause of their problems. This study did not show any increase in knee pain or reoperation between groups. There was an increased subjective ability to kneel in paients whose patellae were not resurfaced. This may have implications for the subset of paeitnts whose work or hobbies may require kneeling. There have been previous reports that subjective ability to kneel and actual ability may differ, and also that kneeling can be taught by a therapist. Our data also shows that female gender had a higher reported rate of kneeling


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 443 - 443
1 Nov 2011
Leszko F Zingde S Argenson J Mahfouz M Komistek R
Full Access

Previosuly, Komistek et al. have shown that the kinematics of the patellofemoral joint is altered after a TKA surgery. Specifically the implanted patella experiences significantly less rotation than the natural patella. Also, in early flexion, the patellofemoral contact positions differed significantly between implanted and non-implanted patellae. It was also found that some of TKA subjects experience patellofemoral separation. These kinematical differences may lead to adverse mechanical conditions and increase fatigue or cause loosening of the implant components. This study’s objective was to determine the three-dimensional patellofemoral kinematics and correlate it with the in vivo sound (vibrations) detected using accelerometers for subjects having a TKA and a non-implanted knee under in vivo, weight bearing conditions. The correlation of the knee mechanical conditions with the vibration data may indicate new parameters that may be used to diagnose the condition of the articular cartilage or implant components. Fifteen subjects (average age 71.8 ±7.4years) having one implanted knee (mobile bearing Hi-Flex PS) and the healthy contralateral knee, performed. deep knee bend to maximum flexion,. chair rise and. stair climb activities under fluoroscopic surveillance. Three miniature, piezoelectric, three-axial accelerometers were attached to the patella and femoral epicondyle. The study was approved by the Institutional Review Board and informed consent was obtained from all subjects. The sensors detected the vibration magnitudes and frequencies of the articulating patellofemoral joint surfaces. The signals were amplified and low-pass filtered at 5 kHz by a signal conditioner. The 3D tibiofemoral and patellofemoral kinematics were derived for both knees using a previously published 3D-to-2D registration technique. The 3D bone models were recovered from CT scans, while implant models were obtained from the manufacturer. The patellofemoral rotations were described using the Grood and Suntay convention. The kinematics and sound data were synchronized and recorded under fluoroscopic surveillance, for 10 patients. Then a subset of seven subjects having a TKA was re-analyzed for their contralateral (non-implanted) knee. The vibration signal was then converted to audible sound and correlated with the 3D kinematics. On average, the subjects achieved more flexion with their TKA (103.4°±15.9°) than with their contralateral knee (96.3°±18.3°). The patellofemoral kinematics varied between the TKA and nonimplanted patella groups; the resurfaced patella experienced less flexion, less medial rotation and less tilt than the contralateral patella. The patellar flexion results were consistent with previously reported literature for both TKA and non-implanted patellae. Also, the resurfaced patellae contacted the femur more proximally than healthy patellae. Audible signals were found for both groups of subjects. The frequency analysis demonstrated that specific frequencies were in similar range for both groups, but the magnitudes and variations were different for the TKA and contralateral knees. This study correlated 3D patellofemoral kinematics with sound under in vivo conditions for three different activities. Variable audible signals were detected for TKA and non-implanted knees. Vibration magnitude and frequency identification, under in vivo conditions, for TKA may lead to a better understanding of wear and failure modes with respect to the patellofemoral mechanics, more specifically, the patellar insert. Currently this initial study is being expanded to degenerated knee joints and failed TKAs for possible applications of the vibration analysis to the early diagnosis of knee arthritis, detection of implant loosening or wear and monitoring of implant osteointegration progress


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 118 - 119
1 Feb 2003
Gill P Keast-Butler O Parikh M Butler-Manuel A
Full Access

The aim of this study was to assess the outcome of patients who underwent ElmslieTrillat antero-medial tibial tubercle transfer for treatment of persistent symptomatic anterior knee pain due to chondromalacia patellae. We performed a prospective analysis of 23 patients who underwent Elmslie-Trillat antero-medial tibial tubercle transfers over a five year period for chronic anterior knee pain and an arthroscopic diagnosis of chondromalacia patellae. All patients who presented with anterior knee pain underwent an initial period of physiotherapy and all patients whose symptoms persisted following physiotherapy underwent arthroscopic assessment. Patients who continued to experience debilitating symptoms despite this initial treatment and who also had a diagnosis of chondromalacia patellae from arthroscopic assessment were listed for an Elmslie-Trillat tibial tubercle anteromedialisation. Patients who gave a history of instability or dislocation were excluded. The average age of patients undergoing surgery was 34 years (21–48 years) and the average time between arthroscopic diagnosis and surgery was 14 months. All patients who underwent surgery had pre and post operative KuJala patellofemoral scoring. The average pre-operative score was 54 (30–78) and post operative score 76 (46–100). The average post operative assessment was 25 months (6–62 months). Twenty one patients had improved post operative scores with one having a worse score and one score remaining unchanged following surgery. Nineteen patients felt that their symptoms had improved, three felt that there had been no change and one felt that they were worse after surgery. When asked if the improvement in symptoms had been worthwhile nineteen stated that they would undergo surgery again if in the same situation and four stated that they would not. The treatment of symptomatic chondromalacia patellae remains a challenge. Although a more selective approach to individuals with anterior knee pain is widely advocated in the literature this study demonstrates that good results can still be achieved in patients treated empirically with a tibial tubercle anteromedialisation


Bone & Joint 360
Vol. 1, Issue 5 | Pages 12 - 14
1 Oct 2012

The October 2012 Knee Roundup. 360. looks at: autologous chondrocytes and chondromalacia patellae; drilling the femoral tunnel at ACL reconstruction; whether we repair the radially torn lateral meniscus; factors associated with patellofemoral pain; mechanoreceptors and the allografted ACL; whether high tibial osteotomy can delay the need for knee replacement; return to sport after ACL reconstruction; tissue-engineered cartilage; and the benefits of yoga


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 468 - 468
1 Sep 2009
Sadoghi P Glehr M Schuster C Kränke B Schöllnast H Pechmann M Quehenberger F Windhager R
Full Access

Whereas thermography has already been used as an assessment of disease activity in some kinds of inflammatory arthritis, it is a new method for objektive pain evaluation in patients with joint prosthesis. To our knowledge, no study has tested the correlation between increase of temperature and anterior knee pain with total knee prosthesis yet. Thirteen patients were included in this study who suffered from anterior knee pain of the retinaculum patellae with total knee prosthesis. The patients were asked to walk 3 km before entering a room which was cooled down to 20 degrees Celsius. A black 1 cm times 4.5 cm square stripe was attached on the diameter of the patella and the patients rested for 20 minutes to cool down before thermographic fotos were taken from 90 degrees, 45 degrees, frontal medial and lateral. The evaluation of temperature difference of each side was performed by marking a 1cm times 2cm square field rectangular around the black stripe and comparing it with a reference point of the same size 3 cm distal of the field. The patients were compared with thirteen others, not suffering from anterior knee pain. Statistical analysis was performed using a t- test and a p value < 0.05 was considered to be significant. The temperature differences between the rectangular field and the reference point increased significantly on the medial (p= 0.00037) or lateral (p= 0.000002) pain side of the knee. The thirteen knees with knee pain had significantly higher temperature differences between medial and lateral temperature differences, than the knees without knee pain. We demonstrate a significant correlation between anterior knee pain and an increase of superficial skin temperature around the retinaculum patellae. To our knowledge, this is the first report of an objective assessment of pain of the retinaculum patellae with total knee prosthesis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 96 - 96
1 Feb 2020
Harris A Christen B Malcorps J O'Grady C Sensiba P Vandenneucker H Huang B Cates H Hur J Marra D Kopjar B
Full Access

Introduction. Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. Materials and Methods. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant (Journey II Bi-Cruciate Stabilized Knee System, Smith & Nephew, Inc., Memphis) were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Results. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m. 2. ; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. Discussion. Reasons for high TKA revision rates in younger patients remain unknown. Conclusion. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 249 - 249
1 Jul 2011
McWalter EJ Wilson DR Harvey WF Lamb KA McCree PI Hunter DJ
Full Access

Purpose: Patellar bracing is a common, mechanical-based treatment strategy for patellofemoral osteoarthritis (OA). It is thought that the brace corrects patellar tracking, however, this correction has not been quantified in the OA population. Through advances in magnetic resonance imaging (MRI), we can now assess patellar tracking in three-dimensions. Method: We assessed three-dimensional patellar tracking in ten subjects with symptomatic radiographic patellofemoral knee OA using a validated, quasi-static, MRI-based method. Four conditions were studied:. no knee brace, no load,. no knee brace, 15% bodyweight (BW) load,. knee brace, no load,. knee brace, 15% BW load. Patellar tracking (flexion, spin and tilt; proximal, lateral and anterior translation) was assessed. Comparisons were made at 1° increments over the coincidental range of knee flexion between the no-brace and brace conditions, at no load and 15% BW load, using a paired t-test with Bonferroni correction. Results: All subjects (7 female, 3 male, 60.9±1.3 yrs, 89.5±19.3 kg) had radiographic lateral patellofemoral OA and seven had concomitant tibiofemoral OA (KL grade≥2). Under no load, the brace extended (mean=2.7°, CI=[2.4°, 2.9°], P< 0.001) and medially tilted (mean=−1.4°, CI=[−1.6°, −1.2°], P< 0.001) the patellae and shifted them distally (mean=0.8mm, CI=[0.6mm, 0.9mm], P< 0.001), medially (mean=0.5mm, CI=[0.5mm, 0.6mm], P< 0.001) and posteriorly (mean=0.6mm, CI=[0.5mm, 0.6mm], P< 0.001). Under 15% BW load, the brace extended the patella (mean=2.4°, CI=[2.1°, 2.8°], P< 0.001) and shifted them distally (mean=1.3mm, CI=[1.1mm, 1.4mm], P< 0.001), medially (mean=0.8mm, CI=[0.7mm, 0.9mm], P< 0.001) and posteriorly (mean 0.6mm, CI=[0.5mm, 0.7mm], P< 0.001). Conclusion: The brace extended the patellae for both loading conditions, suggesting that patellar flexion/extension is restricted by the brace. The brace tilted the patellae medially under no load only, suggesting when the quadriceps are active (15% BW load) the brace has little effect for tilt. While the effect of bracing on patellar tracking may appear small, the differences are of similar magnitude to those observed between normals and patients with patellofemoral pain, suggesting that braces may produce clinically significant changes in patellar tracking


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 470 - 470
1 Apr 2004
Markel D
Full Access

Introduction A biomechanical model was developed to measure wear of all-polyethylene patellar components as it relates to femoral component mal-rotation. The model, based on high load and flexion activities such as stair climbing, was used to differentiate the effects of femoral mal-rotation and differing materials on a single patellar design. Methods The patellar components (Scorpio®, Stryker-Howmedica-Osteonics) were cemented onto metal fixtures and articulated against “aligned” and “mal-aligned” (six degrees internally rotated) femoral components. The patellar components were subjected to a constant force and articulated against femoral components flexing from 600 to 1200. Patellae of identical geometry, made of conventional and highly cross-linked ultra-high molecular weight polyethylene, were tested to 1x106 cycles. Following testing, patellar wear was determined by gravimetric measurement relative to soaked control specimens. Results All conventional polyethylene patellae demonstrated damage in the form of burnishing and scratching of the articular surface. The mal-aligned conventional ultra-high molecular weight patellae demonstrated increased weight loss or wear relative to the aligned components (p=.048). All rotationally mal-aligned highly cross-linked polyethylene components sustained polyethylene fracture or catastrophic failure of the cement-polyethylene construct. Conclusions Rotational mal-alignment of the femoral component will result in increased wear of polyethylene patellar components. The newer highly cross-linked materials failed to resolve this wear problem and sustained catastrophic failure when mal-aligned. Attention needs to be given to the patella-femoral articulation when implanting knee components and when developing new polyethylene as the forces in this articulation may result in polyethylene behaviour that varies dramatically from the femoraltibial articulation. In relation to the conduct of this study, one or more of the authors has received, or is likely to receive direct material benefits


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 256 - 256
1 Jul 2008
LECLERCQ S
Full Access

Purpose of the study: The stability of the patella over the femur depends on several factors, one being the rotatory freedom of the tibia. Femorotibial rotatory laxity of a total knee arthroplasty (TKA) can be:. dictated by the congruence of the polyethylene in an ultracongruent plateau;. completely free, depending solely on the ligament structures in a self-aligning prosthesis;. the consequence of a compromise between the two, using a semi-constrained prosthesis. With the OMNIA system, the unique femoral piece can be combined with a Wallaby ultracongruent plateau (WUC), a self-aligning mobile plateau (SAL), or a semiconstrained plateau with preservation of the posterior cruciate ligament (Wallaby 1, W1). A comparative study of these three prostheses was performed to evaluate the influence of femorotibial rotatory constraint on patellar stability. Material and methods: The series included 157 TKA: 68 SAL,44 WUC and 45 W1. The same surgeon operated all patients in three successive series. The operative technique was the same using the same instrument set. The femoral piece was inserted first with an automatic rotation systematically set at 5° with the posterior condyles. The knees were varus (71%), valgus (20%) and perfectly aligned (9%). A patellar prosthesis was used in only 10.8% due to excessive wear as assessed intraoperatively. A medial approach was used for the varus knees and a lateral approach for the valgus knees greater than 10°, independently of preoperative patellar stability. Radiological outcome was assessed on the 30° femoro-patellar views. Patellae tilted more than 3° and/or offset more than 5 mm were considered to be excentered. Results: In the SAL group, 55 patellae were centered and 13 off-centered. The ratio was 36 for 6 in the WUC group and 39 for 6 in the W1 group. The percentages of centered patellae were respectively 80, 85, and 86%. The difference was not significant (p=0.66. For knees with preoperative genu varum, the percentages of centered patella were 83, 84, and 86%; and for genu varum, 72, 0 and 75% (sample too small for statistical significance). Discussion: The use of rotatory constraint for TKA does not affect patellar stability. This was confirmed in a subpopulation of genu varum knees and not in genu valgum


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 113 - 113
1 May 2011
Heinert G Kendoff D Gehrke T Preiss S Sussmann P
Full Access

Introduction: Mobile bearing TKRs may allow some axial rotation and also compensate for a slight tibiofemoral rotational mismatch. This is thought to provide better kinematics and a more natural patellar movement. This theoretical advantage has not been verified in clinical studies for the tibiofemoral kinematics. However, little is known about the patellofemoral kinematics of mobile bearing TKRs. The aim was to compare patellar kinematics among the anatomic knee, fixed bearing TKR and mobile bearing TKR. Methods: Optical computer navigation marker arrays (Brainlab) were attached to the femur, tibia and patella of 9 whole lower extremities (5 fresh cadavers). The trial components of a fixed bearing posterior stabilised TKR (FB) (Sigma PFC, Depuy) were implanted using a tibia first technique. Then the tibia component was changed to a posterior stabilised mobile bearing tibia component (MB) (Sigma RP Stabilised). The patellae were not resurfaced. The knees were moved through a cycle of flexion and extension on a CPM machine. Medial/lateral shift and tilt was measured relative to the patella position in the natural knee at full extension always with soft tissue closure. The path of the trochlea and patellar groove of the femoral component was registered. Values are expressed as mean+/−one standard deviation. Statistical analysis: two tailed paired Student’s T-test. Results: M/L shift: There was a tendency for the patella to track 2mm more laterally throughout the flexion range with a FB or MB TKR compared to the natural knee, but this did not reach significance. Tilt: The patella in the natural knee tilted progressively laterally from extension to flexion, plateauing at 50° of flexion (20°: 1.9+/−2.7°, 40°: 5.6+/−5.4°, 60°: 6.2+/−6.4°, 80°:6.5+/−7.3°, 90°: 6.4+/−7.7°). With a FB or MB TKR the patellae also tilted laterally up to 50 degree of flexion, but then started to tilt back medially, reaching the neutral position again at 90°. The patellae of the FB and MB TKRs were significantly more medially tilted at 50° to 90° of flexion compared to the natural knee. But there was no difference between the FB and MB TKRs. (Fixed bearing: 20°: 2.5+/−7.2° p=0.30, 40°: 3.7°+/−6.5° p=0.15, 60°: 3.1+/−5.8° p=0.02, 80°:1.2+/−6.5° p=0.001, 90°: 0.3+/−7.2° p=0.001, Mobile bearing: 20°: 0.3+/−5.5° p=0.27, 40°: 3.6+/−5.2° p=0.08, 60°: 2.1°+/−5.8 p=0.01, 80°: 0.2+/−6.8 p=0.003, 90°: −0.6+/−7.3 p=0.002; vs. natural). Trochlea position: The centre of the patellar groove of the femur component was more lateral than the trochlea by 2–5mm, it also extended 10mm further proximally. Conclusion: There are kinematic differences in patellar tracking between the natural and a FB/MB TKR. This may be due to a slightly different position of the patellar groove. The patellar kinematics of the MB TKR is not more natural compared to the FB TKR


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 734 - 739
1 Jun 2006
Campbell DG Duncan WW Ashworth M Mintz A Stirling J Wakefield L Stevenson TM

A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II prosthesis, with or without a cemented polyethylene patellar component. Knee function was evaluated using the American Knee Society score, Western Ontario and McMaster University Osteoarthritis index, specific patellofemoral-related questions and radiographic evaluation until the fourth post-operative year, then via questionnaire until ten years post-operatively. A ten-point difference in the American Knee Society score between the two groups was considered a significant change in knee performance, with α and β levels of 0.05. The mean age of the patients in the resurfaced group was 71 years (53 to 88) and in the non-resurfaced group was 73 years (54 to 86). After ten years 22 patients had died, seven were suffering from dementia, three declined further participation and ten were lost to follow-up. Two patients in the non-resurfaced group subsequently had their patellae resurfaced. In the resurfaced group one patient had an arthroscopic lateral release. There was no significant difference between the two treatment groups: both had a similar deterioration of scores with time, and no further patellofemoral complications were observed in either group. We are unable to recommend routine patellar resurfacing in osteoarthritic patients undergoing total knee replacement on the basis of our findings


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 71 - 73
1 Feb 1978
Marks K Bentley G

The Insall-Salvati method of determining the position of the patella by radiography was employed in fifty-one patients with chondromalacia patellae that had been proved at arthrotomy. There was no definite relationship between chondromalacia patellae and patella alta. There was, however, a highly significant statistical difference between the ratio of the length of the patella to that of the patellar tendon in normal men and women


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 241 - 242
1 May 1977
Blackburne J Peel T

To measure the patellar height the ratio of the articular length of the patella to the height of the lower pole of the articular cartilage above the tibial plateau is measured on a lateral radiography of the knee, flexed beyond 30 degrees. Normal values lie between 0-54 and 1-06. The subluxing patella is at the upper end of the normal range, but, in chondromalacia, the male patellae were lower than average, but the female patellae were normal


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 124 - 124
1 Mar 2010
Parratt M Waters T Carrington R Skinner J Bentley G
Full Access

Orthopaedic surgeons vary in their attitude towards resurfacing of the patella in total knee arthroplasty. Few studies are available to assess outcome and patient preference. We evaluated post-operative anterior knee pain and knee preference in patients with bilateral knee replacements and unilateral patellar resurfacing. We reviewed 30 patients who had undergone bilateral knee replacement with patellar resurfacing on only one side. Follow-up was from five to 12 years and the patients were assessed using the Knee Society rating, an anterior knee pain rating and a satisfaction score. Patients were also asked specifically if they had a preference for either knee. Assessment was performed without knowing which patella had been resurfaced. Fourteen patients (47%) favoured the resurfaced knee, six (20%) the un-resurfaced knee and 10 (33%) had no particular preference. The overall prevalence of anterior knee pain was 50% in the un-resurfaced cases (six mild, six moderate, three severe) and 20% in the resurfaced knees (four mild, two moderate). No significant difference was found between knee scores. Three un-resurfaced patellae have been secondarily resurfaced. This study shows a significant preference for the resurfaced side (p< 0.01), with a higher prevalence of anterior knee pain in non-resurfaced patellae (p< 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 3 - 7
1 Jan 1987
Eisenstein S Parry C

We describe a lumbar facet syndrome in which disabling symptoms are associated with normal or near-normal plain radiographs. Local spinal fusion relieved symptoms in 12 patients; the excised facet joint surfaces showed some of the histological changes seen in chondromalacia patellae and in osteoarthritis of other large joints. The most frequent change was focal full-thickness cartilage necrosis or loss of cartilage with exposure of subchondral bone, but osteophyte formation was remarkably absent in all specimens. We suggest that there are both clinical and histological similarities between the facet arthrosis syndrome and chondromalacia patellae. Facet arthrosis may be a relatively important cause of intractable back pain in young and middle-aged adults


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 338 - 338
1 Sep 2005
Schepers A Van der Jagt D
Full Access

Introduction and Aims: Many authors believe that patellar resurfacing decreases the incidence of anterior knee pain. We analysed the result of 150 of our own patients. Method: Over the past four years we performed 150 total knee arthroplasties. None of the patellae were resurfaced, osteophytes were carefully removed, the patellae debrided, a thorough peri-patellar synovectomy and circumpatellar cautery denervation performed. All patients were examined by a consultant and a registrar to determine the site of any pain complaint. If there was any controversy a third surgeon was consulted. Results: No patient had pain severe enough to warrant revision surgery. Only two patients had anterior knee pain, and in neither was it marked. Conclusion: We do not know whether our favourable results are attributable to the patellar management, or due to the prosthesis used. We concede that a prospective randomised trial is necessary to determine this, but with such a low incidence of patellar complications we feel this is not ethically justified


Bone & Joint Open
Vol. 5, Issue 6 | Pages 464 - 478
3 Jun 2024
Boon A Barnett E Culliford L Evans R Frost J Hansen-Kaku Z Hollingworth W Johnson E Judge A Marques EMR Metcalfe A Navvuga P Petrie MJ Pike K Wylde V Whitehouse MR Blom AW Matharu GS

Aims

During total knee replacement (TKR), surgeons can choose whether or not to resurface the patella, with advantages and disadvantages of each approach. Recently, the National Institute for Health and Care Excellence (NICE) recommended always resurfacing the patella, rather than never doing so. NICE found insufficient evidence on selective resurfacing (surgeon’s decision based on intraoperative findings and symptoms) to make recommendations. If effective, selective resurfacing could result in optimal individualized patient care. This protocol describes a randomized controlled trial to evaluate the clinical and cost-effectiveness of primary TKR with always patellar resurfacing compared to selective patellar resurfacing.

Methods

The PAtellar Resurfacing Trial (PART) is a patient- and assessor-blinded multicentre, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary TKR for primary osteoarthritis at NHS hospitals in England, with an embedded internal pilot phase (ISRCTN 33276681). Participants will be randomly allocated intraoperatively on a 1:1 basis (stratified by centre and implant type (cruciate-retaining vs cruciate-sacrificing)) to always resurface or selectively resurface the patella, once the surgeon has confirmed sufficient patellar thickness for resurfacing and that constrained implants are not required. The primary analysis will compare the Oxford Knee Score (OKS) one year after surgery. Secondary outcomes include patient-reported outcome measures at three months, six months, and one year (Knee injury and Osteoarthritis Outcome Score, OKS, EuroQol five-dimension five-level questionnaire, patient satisfaction, postoperative complications, need for further surgery, resource use, and costs). Cost-effectiveness will be measured for the lifetime of the patient. Overall, 530 patients will be recruited to obtain 90% power to detect a four-point difference in OKS between the groups one year after surgery, assuming up to 40% resurfacing in the selective group.


The purpose of this study was to evaluate a high flex porous tantalum metal monoblock component system implanted through a MIS technique. A fellowship trained surgeon proficient in MIS surgery performed 109 consecutive TKAs in 95 patients. Patients were implanted with a tantalum monoblock tibia and a fiber-metal cruciate-retaining high flex femur through a MIS midvastus approach. Ninety uncemented porous tantulum monoblock patellae and 19 cemented all polyethylene patellae were implanted. Knee Society scores and Knee Society radiographic scores were calculated in all patients. Follow-up for a minimum of 2 years was performed in 109 knees. The average follow up was 39 months. Sixty-six percent of the patients were female and 34% male. The average age was 66 years. The average preoperative Knee Society Knee score was 36. The average preop Knee Society Functional Score was 46. Osteoarthritis was the primary diagnosis in 104 knees. Rheumatoid arthritis and Hemophilia was the diagnosis in two knees each. The average Knee Society Knee Score improved to 89. The average Knee Society Function score improved to 86. 106 of the knees were rated good or excellent and three knees were rated poor. Two patellar revisions were performed for loose components and one for patellar misalignment. One patella fracture occurred that required ORIF. One femoral component was revised for loosening. There were nonprogressive radiographic lucencies demonstrated on 4 tibial components. One tibial component was rated loose. There were radiographic lucencies on 5 femoral components, all nonprogressive. There were two uncemented tantalum patellar components with stable radiolucencies. Early results in 109 consecutive porous tantalum metal tibial and high flex cruciate-retaining femoral components implanted through an MIS midvastus approach have a high rate of success at a minimum followup of two years


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 11 - 11
1 Mar 2012
Heinert G Kendoff D Gehrke T Preiss S Sussmann P
Full Access

Introduction. Mobile-bearing TKRs allow some axial rotation and may provide a more natural patellar movement. The aim was to compare patellar kinematics among the normal knee, fixed-bearing and mobile-bearing TKR. Methods. Optical computer navigation (Brainlab) was used to track the position of the femur, tibia and patella in 9 whole lower extremities (5 fresh cadavers) in the natural knee, in the same knee with the trial components of a posterior stabilised fixed-bearing TKR (FB) (Sigma PFC, Depuy) and a posterior stabilised mobile-bearing TKR (MB) (Sigma RP Stabilised). The patellae were not resurfaced. Values: mean+/−one standard deviation. Statistical analysis: two tailed paired Student's T-test. Results. M/L shift: There was a tendency for the patella to track 2mm more laterally with a FB or MB TKR compared to the natural knee, but this did not reach significance. Tilt: The patella in the natural knee tilted progressively laterally from extension to flexion, plateauing at 50° of flexion (20°: 1.9+/−2.7°, 40°: 5.6+/−5.4°, 60°: 6.2+/−6.4°, 80°:6.5+/−7.3°, 90°: 6.4+/−7.7°). With a FB or MB TKR the patellae also tilted laterally up to 50 degree of flexion, but then started to tilt back medially, reaching the neutral position at 90° again. There was no difference between the FB and MB TKRs. (Fixed bearing: 20°: 2.5+/−7.2° p=0.30, 40°: 3.7°+/−6.5° p=0.15, 60°: 3.1+/−5.8° p=0.02, 80°:1.2+/−6.5° p=0.001, 90°: 0.3+/−7.2° p=0.001, Mobile bearing: 20°: 0.3+/−5.5° p=0.27, 40°: 3.6+/−5.2° p=0.08, 60°: 2.1°+/−5.8 p=0.01, 80°: 0.2+/−6.8 p=0.003, 90°: -0.6+/−7.3 p=0.002; vs. natural). Trochlea position: The centre of the patellar groove of the femur component was more lateral than the trochlea by 2-5mm, it also extended 10mm further proximally. Conclusion. There are kinematic differences in patellar tracking between the natural knee and a FB/MB TKR. Compared to the FB TKR the patellar kinematics of the MB TKR is not more natural


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 54 - 58
1 Jan 2014
Vijayan S Bentley G Rahman J Briggs TWR Skinner JA Carrington RWJ

The management of failed autologous chondrocyte implantation (ACI) and matrix-assisted autologous chondrocyte implantation (MACI) for the treatment of symptomatic osteochondral defects in the knee represents a major challenge. Patients are young, active and usually unsuitable for prosthetic replacement. This study reports the results in patients who underwent revision cartilage transplantation of their original ACI/MACI graft for clinical or graft-related failure. We assessed 22 patients (12 men and 10 women) with a mean age of 37.4 years (18 to 48) at a mean of 5.4 years (1.3 to 10.9). The mean period between primary and revision grafting was 46.1 months (7 to 89). The mean defect size was 446.6 mm. 2. (150 to 875) and they were located on 11 medial and two lateral femoral condyles, eight patellae and one trochlea. . The mean modified Cincinnati knee score improved from 40.5 (16 to 77) pre-operatively to 64.9 (8 to 94) at their most recent review (p < 0.001). The visual analogue pain score improved from 6.1 (3 to 9) to 4.7 (0 to 10) (p = 0.042). A total of 14 patients (63%) reported an ‘excellent’ (n = 6) or ‘good’ (n = 8) clinical outcome, 5 ‘fair’ and one ‘poor’ outcome. Two patients underwent patellofemoral joint replacement. This study demonstrates that revision cartilage transplantation after primary ACI and MACI can yield acceptable functional results and continue to preserve the joint. Cite this article: Bone Joint J 2014;96-B:54–8


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages 76 - 76
1 Mar 2002
Hooper G
Full Access

Since its introduction in Christchurch in 1989, the mobile bearing LCS prosthesis has been used in over 3 500 total knee arthroplasty (TKA) procedures. The prosthesis is unique in that it has a mobile articulation not only at the tibiofemoral joint but also at the patellofemoral joint. The tibiofemoral articulation may be posterior cruciate retaining (meniscal bearings - MB) or sacrificing (rotating platform - RP). Clinical and radiological assessment of 569 patients over three to nine years shows no significant difference between MB and RP groups with respect to Knee Society and New Jersey knees or the WOMAC functional score. In 93% of patients results were good or excellent. There were more early complications among MB patients, with five MB dislocations. However, four of these dislocations occurred in the early years this prosthesis and may reflect surgical inexperience. Clinical evidence of posterior cruciate laxity was present in 15% of the MB group, but there was no significant difference between knee scores of this group, the rest of the MB group, or the RP group. When resurfaced patellae were compared to knees that were not resurfaced, there was no significant difference. Patellae with more than 4 mm of lateral subluxation were identified, but their knee scores were not significantly different. The early to medium-term results of our continuing study of the LCS mobile bearing prosthesis are at least comparable to those of studies of fixed bearing prostheses. We continue to use this implant with confidence, but await long-term results


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 850 - 858
1 Sep 1998
Schai PA Thornhill TS Scott RD

A consecutive series of 235 total knee arthroplasties using the PFC system was followed prospectively for at least ten years in 186 patients. The operation was for osteoarthritis in 150 knees, for rheumatoid arthritis in 83, and for Paget’s disease and femoral osteonecrosis in one knee each. At the latest review 56 patients had died, fi ve were too ill to assess and three could not be traced. The PFC knee replacement utilised was a nonconforming posterior-cruciate-retaining prosthesis with a polyethylene insert which is fl at in the sagittal plane. The patella was resurfaced using a metal-backed component in 170 cases, but later in the series we used an all-polyethylene component in 22 knees; 43 patellae were not resurfaced. The survival without need for reoperation for any reason was 90% at ten years. Nineteen revisions were component-related due to failure of nine metal-backed patellae, nine polyethylene inserts, and one unresurfaced patella; two reoperations were for synovectomy (one for recurrent haemarthrosis and one for recurrent rheumatoid synovitis) and three were for metastatic joint infection. There were no revisions for aseptic loosening of femoral or tibial components, or the all-polyethylene patellar replacement. The PFC system provides good and predictable results in tricompartmental arthritis of the knee. Loosening appeared to be negligible, but there were wear-related problems in 8%. The change from a metal-backed patella and an increase in the contact area of the tibial insert should provide further improvement by minimising wear


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 452 - 452
1 Apr 2004
Erasmus P
Full Access

To stabilise the dislocating patella, one can increase the medial vectors, decrease the lateral vectors, or combine these options. Oblique strengthening of vastus medialis increases the medial vectors. This muscle is an active secondary constraint for stabilising the patella. Strengthening this muscle is the cornerstone of treatment of patellar instability, but it is often unsuccessful if the medial patello-femoral ligament is deficient. The medial patellofemoral ligament is the primary passive constraint to lateral dislocation of the patella. Reconstruction of this ligament, which tenses in extension, stabilises the patella in most cases, without the danger of secondary late-stage patellofemoral degeneration. However, in high-riding patellae, effective ligament reconstruction may cause an extensor lag. An elevation of more than 3 mm affects the contact pressures by disturbing the unique relationship between patella and trochlea. Because it can lead to late stage patellofemoral degeneration, trochleaplasty is rarely indicated. Tibial tubercle transfer decreases the lateral vectors and is indicated in cases of severe patella alta, a markedly increased Q-angle and lateral patellar tilt. The tubercle can be transferred distally or medially or internally rotated. The procedure changes the patellofemoral relationship, increasing the load in the medial tibio-femoral compartment and giving rise to the possibility of late-stage degeneration in both the patellofemoral and the tibiofemoral joints. It should not be undertaken lightly and the amount of shift should be conservative. The lateral retinaculum, which becomes lax in extension in right in flexion, provides about 10% of patellar stability to lateral dislocation. Because most patellae dislocate in early flexion, lateral retinacular release is seldom indicated except in the rare cases where the patella dislocates in late flexion. In severe cases of patellar instability, it might be necessary to combine reconstruction of the medial patello-femoral ligament with tibial tubercle transfer and even with lateral retinacular release


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 433 - 433
1 Apr 2004
Krevolin J Shen M Muratoglu O Harris W
Full Access

Although complications associated with patello-femoral (PF) joint account for up to 50% of total knee replacement (TKR) revision procedures (Lee), the PF joint has been overlooked in wear simulations. The goal of this study was to develop an in vitro model to simulate patella wear in TKR’s. This report describes the concepts of an in vitro model for normal gait and the preliminary results of experimental validation. The primary consideration in the development of the current model was modeling of the in vivo kinetics and kinematics. Since the in vivo kinetics are not well documented, the current model adapted a PF joint force pattern of gait measured one year postoperatively in a telemetric distal femoral replacement (Taylor et al). The maximum force was increased from 571N to 1780N (2.5xBody Weight) to compensate for muscle deficiency and to better reflect a maximum load representative of the in vivo situation. In vivo kinematics were adopted from measurements of Lafortune. Only the PF flexion was included in the model as a simplification of the complex patella motions. The phase relationship between the kinematic and kinetic waveforms was adjusted to replicate the in vivo situation. A 6-station knee simulator carried out the experimental validation with a test frequency of 1.5Hz. The test was intended to run for 5 million cycles, with CMM wear measurements (Muratoglu et al.) taken every million cycles. The preliminary measurements showed wear patterns in the tested patellae similar to retrieved patellae. Currently there are no standards for wear testing the PF joint. The current in vitro wear model presents a useful tool to critically assess the PF joint during gait. Future work should incorporate testing for adverse loading conditions, such as PF mal-alignment, rising from a chair or deep knee flexion


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 249 - 249
1 Mar 2013
Maiti R Fisher J Jin Z Rowley L Jennings L
Full Access

Introduction. Patella femoral joint bearings in total knee replacements have shown low wear (3.1 mm. 3. /MC) under standard gait simulator conditions. 1. However, the wear in retrieval studies have shown large variations between 1.3 to 45.2 mm. 3. /year. 2. Previous in vitro studies on the tibial femoral joint have shown wear is dependent on design, materials and kinematics. 3. . The aim of this study was to investigate the influence of the design (geometry) and shape on the wear rate of patella femoral joints in total knee replacements. Materials and Methods. The Leeds/Prosim knee simulator was used to investigate the wear of two types of commercially available patellae. The PFC Sigma cobalt chrome femoral component was coupled with 2 types of patellae buttons: round and oval dome. The UHMWPE was the same for the both types – GUR1020 GVF (gamma irradiated in vacuum and foiled packed). 25% bovine serum was used as the lubricant. The test were carried out at three conditions – high medial lateral (ML) rotations (<4°) and uncontrolled ML displacement (<4 mm), low ML rotation (<1°) and uncontrolled ML displacement (<4 mm); the physiological gait cycle; and low ML rotation and controlled ML displacement (<1.5 mm). In this abstract the two designs were tested in physiological gait condition (Figure 1). Patella ML displacement and tilt were passively controlled and measured after every 300,000 cycles. A ligament resisting force equivalent to 10 N4 was applied on the lateral side of the patella to avoid patella slip. Five samples of each design were tested for 3 million cycles at a cycle rate of 1 Hz. The wear volume was obtained gravimetrically every million cycles and presented with 95% confidence limits. Statistical significance was taken at p<0.05. Results and Discussions. The wear rate of PFC sigma round dome patella was higher (8.63 ± 3.44 mm. 3. /million cycles) compared to the PFC sigma oval dome patella (6.28 ± 3.89 mm. 3. /million cycles) (Figure 2). However, no significant difference in the wear rates was found between the two shapes (P=0.2). The low area of contact of oval dome patella (31.2% of total surface area) as compared to round dome patella (39.9%) led to low wear. 5. . The wear volume and the patellar tilt were positively correlated for oval dome and round dome patella, R. 2. > 0.9 (Figure 3). Increase in the patellar tilt resulted increase in sliding distance in perpendicular direction of polymer orientation. This led to higher wear volume. Conclusions. Wear rate decreased with change of patella shape from round dome to oval dome although not significantly. Increase in the patellar tilt resulted in increase in the wear volume. Acknowledgement. This research was supported in part by the DePuy and EPSRC. In addition, it was partially funded through WELMEC, a Centre of Excellence in Medical Engineering funded by the Wellcome Trust, under grant number WT 088908/Z/09/Z and additionally supported by the NIHR (National Institute for Health Research) as part of collaboration with the LMBRU (Leeds Musculoskeletal Biomedical Research Unit)


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 393 - 393
1 Sep 2009
Hakki S
Full Access

Most common complication of non-navigated classic total knee arthroplasty (TKA) relates to patella. Not resurfacing the patella makes exposure more difficult in a mini-approach which may add to its potential complications. Effect of navigated mini sub-vastus TKA on native patella is clinically and radiologically studied, observing also, whether severity of deformity or obesity adds to patellae complications in such approach. 92 of 100 subjects were eligible. Peri-operative radiological and navigation data with follow up visits to 24 months provided alignment, patella tilting or displacement data. Clinical outcome gauged by “KSS” documented pain from patella movements, or pain generated from stair climbing, or rising from a chair. Patella is considered subluxated if it displaced ≥ 5mm. No exclusion by obesity or severity of deformity. Results were evaluated with descriptive statistics. Of the 92 patients, 3 had patella pain (3%). 72% had < 5° of patella tilting (of which 3 had patella pain) while 28% had a 5°–17° tilting. As for patellae displacement, 12% displaced laterally (≤3 mm) but with no pain. None had patellar displacement ≥ 4mm (which we define as subluxation), and none had a dislocation. Pre-operative knee deformity ranged from 19° varus to 13° of valgus. 70% of subjects had pre-operative varus/valgus deformity of < 10°. The other 30% had deformity of ≥ 10°. Post-operative mean mechanical axis alignment was 0° (± 1°) with a mean range of motion of −3.8° to 133.6°. No vascular injuries, skin necrosis, deep infection, or fractures. The BMI ranged from 25–46 Kg/m. 2. 16% had a BMI ≥ 40 with no patellar pain, tilting or displacement. Incidence of native patella pain in a navigated mini sub-vastus TKA was low irrespective to body mass or pre-operative deformity. Perhaps navigation helped align the components ideally and thus reducing the complication rate of a mini-approach. However, 28% of native patella tilted > 5° but unlike tilting of a resurfaced patella, it did not correlate with patella pain. In this study, whether non-resurfacing caused the 3% of patella pain is undetermined. Nevertheless, the pain level was not severe to make the patients seek a revision of the patella. Finally, as we compare with other studies, we cannot conclude that mini sub-vastus approach is superior; however its low patella complication rate is comparable if not superior to classic approach


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 127 - 127
1 Apr 2019
Yamada K Hoshino K Tawada K Inoue J
Full Access

Introduction. We have been re-evaluating patellofemoral alignment after total knee arthroplasty (TKA) by using a weight- bearing axial radiographic view after detecting patellar maltracking (lateral tilt > 5° or lateral subluxation > 5 mm) on standard non-weight-bearing axial radiographs. However, it is unclear whether the patellar component shape affects this evaluation method. Therefore, we compared 2 differently shaped components on weight-bearing axial radiographs. Methods. From 2004 to 2013, 408 TKAs were performed with the same type of posterior-stabilized total knee implant at our hospital. All patellae were resurfaced with an all-polyethylene, three-pegged component to restore original thickness. Regarding patellar component type, an 8-mm domed component was used when the patella was so thin that a 10-mm bone cut could not be performed. Otherwise, a 10-mm medialized patellar component was selected. Twenty-five knees of 25 patients, in whom patellar maltracking was noted on standard axial radiographs at the latest follow-up, were included in this study. Knees were divided into 2 groups: 15 knees received a medialized patella (group M) while 10 received a domed patella (group D). Weight-bearing axial radiographs with patients in the semi-squatting position were recorded with the method of Baldini et al. Patellar alignment (tilt and subluxation) was measured according to the method described by Gomes et al. using both standard and weight-bearing axial views. Results. Patients’ demographic data, such as age at surgery, sex, and disease were similar for both groups. The average follow-up period was significantly longer in group D than group M (5.4 years vs. 2.5 years, respectively; p = 0.0045, Mann- Whitney U-test). The lateral tilt angle decreased significantly (p < 0.0001, paired t-test) from 6.5° ± 2.8° to 1.0° ± 1.2° with weight bearing in group M. However, this parameter in group D changed from 6.7° ± 2.7° to 4.7° ± 3.0° with weight bearing; the difference was not significant. Lateral subluxation also decreased significantly (p < 0.0001, paired t-test) from 5.1 mm ± 2.4 mm to 2.5 mm ± 1.4 mm with weight bearing in group M. However, that in group D changed from 2.8 mm ± 2.7 mm to 2.4 mm ± 2.8 mm with weight bearing, and the difference was not significant. On weight-bearing views, patellar maltracking was noted in 4 knees in group D but no knees in group M. The difference was significant (p = 0.017, Fisher's exact test). One of the 21 patients with adequate patellar tracking (4.8%) and 1 of 4 patients with maltracking (25%) complained of mild anterior knee pain. Discussion. Patellar tracking on axial radiographic views improved better in group M than in group D with weight bearing. The patellofemoral contact area was maintained with a domed patella despite tilting, but not with a medialized patella. Our results indicate that the shape difference affected the degree of radiographic improvement. Thus, the weight-bearing axial radiographic view devised by Baldini et al. is useful for evaluating patellofemoral alignment after TKA, but the shape of the patellar component should be considered for result interpretation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 351 - 351
1 May 2010
Friedl W Gehr J
Full Access

Clinical Problem: fractures under tension are common injuries and occur when patients are falling on partial flexed limbs under maximal contraction of the extensor muscles. Typical injuries are patella and olecranon. For these fractures the tension belt osteosyntheses is the mainly used procedure. A high complication rate regarding dislocation, bone healing, pain and functional outcome are reported. This is due to the unstable fixation with the tension belt because of the tendon insertion around the bone fragment witch allow secondary loosening of the tension belt under alternating load. This was found allready 1987 by Brill and Hopf in an experimental study. Materials and Methods: To improve stabilisation a new device was developed: the XS (4,5mm diameter) and the XXS nail (3,5mm) witch is locked with threaded wires and a set screw allows fracture compression inside the nail independend from the soft tissues around. Fiber Wire cerclage transversal around the threaded wire ends allow the fixation of additional frontal plane fragments or marginal fragments. Experimental test were performed in a patella sow-bone models and showed superior to tension bel (patella) and Plate fixation/fibula). On the other side the locked nail system allows percutaaneous osteosynthesis of the whole ulna also in shaft, distal fractures and shortening osteotomies. All clinical cases treated with the XS/XXS nail where recorded prospectively and re-examined after 6–12 months. From may 2000 to march 2002 76 patients with olecranon fractures were evaluated. 85% of the olecranon fracture patients could be re-examined. Most patients where treated immediately or after wound healing without splint. Results: the experimental results shows in all XS nail group no gap after alternating load of 250 and 500N and a rigidity a little higher than that of the not osteotomised patellae. In the tension belt groups in all tested patellae visible gaps of 1 to 3 mm occurred. There was no difference between the single and double XS nail Osteosynthesis. 71.7% of all patients with olecranon fractures showed a very good result according to the Murphy score. In 2 part fractures the rate was even 94.7%. Only in the group of more part fractures in 5.9% fair results were found. No patient showed a poor result. The technical possibilities of XS nail osteosynthesis in ulna shaft, distal fractures and shortening osteotomies are presented. Conclusions: the XS nail is a new device witch allows good anatomical reconstruction and stable fixation with immediate functional therapy in all olecranon and ulna fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 92 - 92
1 Sep 2012
Korduba L Klein R Essner A Kester M
Full Access

INTRODUCTION. Wear and fracture of patellar components has been frequently reported as a failure mode for cemented and press-fit patellar components. Malalignment of the patellar components may cause higher contact stresses, which may lead to excessive wear, delamination, and/or component fracture. In vitro testing of the patella in a clinically relevant malaligned condition is necessary to demonstrate adequate performance of the patellar component and assess the endurance of its fixation features under severe loading conditions. The purpose of this study was to test in vitro the patellar components under malaligned conditions using a knee joint simulator. MATERIALS AND METHODS. A 6 station MTS (Eden Prairie, MN) knee joint wear simulator and Alpha Calf Fraction serum (Hyclone Labs, Logan, UT) diluted to 50% with a pH-balanced 20-mMole solution of deionized water and EDTA was used (protein level = 20 g/l) for testing. Asymmetric, all-polyethylene, patellar components with an overall construct thickness of 11 mm (Duracon®, Stryker Orthopaedics, Mahwah, NJ) were used. Appropriately sized cobalt-chrome femoral components articulated against the patellae. The patellae were cemented (Simplex, Stryker Orthopaedics, Mahwah, NJ) to delrin fixtures, which placed the patella in 10° of lateral tilt (Figure 1). This angle was chosen based off the work of Huang et al, which was one of the larger average tilt angles reported in vivo. Replicating this scenario in vitro allows for observation of the potential scenario that may occur as the femoral component maintains contact strictly on the thinner lateral edge of the patella, concentrating both the axial and shear loads on a small area of polyethylene. The loading and kinematic profiles used for testing were published previously (maximum axial load: 2450N and maximum patellofemoral angle: 54°. Variations of the loading profile were studied by evaluating the effects of heavier patients, which increased the maximum axial load to 3100N(250lb patient) and 3750N(300lb patient) (Figure 2). Lateral offset was tested to evaluate the effect of malalignment. Increments of 1mm were analyzed starting from the neutral position, eventually reaching a maximum lateral offset of 5mm. A 6-dof load cell was placed beneath the patella fixturing to capture dynamic loads (ATI, Apex, NC). The axial and medial/lateral shear loads where used to calculate the resultant medial/lateral shear force being applied to the patellar pegs. RESULTS. The results of using a heavier loading profile and increasing lateral offset are shown in Figure 3. At neutral alignment, the effect of increasing the axial load caused an increase of 10% in resultant shear force. At 5 mm of lateral offset, the increase in loading caused the shear force to increase by 16%. With each loading profile, increasing the lateral offset from 0 to 5 mm caused the resultant shear force to increase two-fold. DISCUSSION. This test model allows for an aggressive method of testing patellar implants and it includes variables to adjust for severity (lateral offset and joint reaction force). Although increasing the amount of lateral patellar offset increases the resultant shear forces, the patellar wear rates remained minimal and constant. Hence, a femoral component that has a forgiving patellar tracking may demonstrate minimal wear, even when evaluated in extremely aggressive test conditions. Note: These results are specific to the device used since the results will be dependant on the function and design of the patellar implant and patella/femur track


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages 88 - 88
1 Mar 2002
Erasmus P
Full Access

During knee arthroplasty operations, it appeared that different patterns of patellar degeneration occur. To confirm this, 123 patellae were evaluated in a prospective study. The patellae of patients who had undergone patellar surgery or osteotomy were excluded. The femur was divided into three condyles and nine areas, and the patella into three facets and nine areas. Areas of grade-III or more degeneration on the patella and femoral condyle were recorded. In 74 knees (60%), the patellar degeneration was less than grade III. In 49 (40 %), the patellar degeneration was grade III or more. In these 49 knees, there were 122 lesions in the nine areas of the femur and 77 lesions in the nine areas of the patella. These lesions were analysed to determine the most common areas of femoral and patellar degeneration. Further analysis was undertaken to determine whether there was any pattern of degeneration between the patellar and femoral lesions. The medial femoral condyle, central and central-medial patella had the highest incidence of degeneration. These probably represent areas of greatest load-bearing in the knee. The areas with least degeneration were in the lateral femur and the superior patella, probably the lowest load-bearing areas. It was noted that any pattern of patellar degeneration could occur with any pattern of femoral degeneration. Lateral and central patellar facet degeneration is a well-recognised clinical and radiological condition. Medial patellar facet degeneration was a common finding. The medial facet is especially loaded in the flexed knee. A fixed flexion contractor, common in medial compartment osteoarthritis, may partially explain the high incidence of medial facet degeneration in these patients. Medial patellar facet degeneration is not a well-recognised condition and in the literature is generally considered secondary to lateral release. In this series, patients with lateral releases were excluded. Standard patellar skyline views show only the unloaded medial facet. Medial patellar facet degeneration is probably more common than is clinically recognised, and may account for unexplained anterior knee pain, especially in the flexed knee. In this situation, pain will be aggravated by a lateral retinacular release


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 302 - 302
1 Mar 2004
Paavolainen P Nevalainen J Pulkkinen P
Full Access

Aims: The most common complications after total knee arthroplasty (TKA) are the result of patellar complications. The causes of patellar problems range from sub-luxation, dislocation, component loosening, rupture of the patellar tendon, excess wear of the polyethylene (especially after metal backing), retropatellar pain, and patellar fracture. The incidence of these patellar complications after TKA ranges from 5–30%. Selective retention of the patella has been recommended more recently although there are still potential problems of maltracking and anterior knee pain. According to the nationwide registration of all TKAs in Finland since 1980 it seems evident that interest of patellar retention during the primary operation has now been stabilized at the level of about 55 per cent. At the same time there are, however, quite a high incidence of reoperations done due to patellar complications or later resurfacing of the patella in connection of revisions done with other indications. Methos:. Database of the Finnish Arthroplasty Register was evaluated from the years 1999 and 2000 focusing on the reoperations done either due to patellar complication (in the notiþcation: indication for revision) or due to other reason (to be speciþed in full text). These were further divided into three main categories: removal or fracture of patellae, delayed resurfacing due to patellar pain or maltracking, and component loosening. Conclusions: Reoperations done due to the patellar complications and/or later resurfacing of patellae mean quite a notable work-load; 31,7 to 33,6 per cent of all TKA revisions done in the years 1999 and 2000, respectively. Of the total of 113 delayed patellar resurfacing operations, almost 50 per cent were done in connection to revisions primarily due to other reasons, usually after excess liner wear. In conclusion we can say, that ÒprimaryÒ patellar complications (after patellar resurfacing in the primary operation) encountered about 15 per cent of all revisions, and those done in the Òsecondary phaseÒ (after retention of patella) another 15 to 16 per cent. This is in accordance with the results gained in the other Nordic Registers; in Norway ÒprimaryÒ/loose 16,5% of all TKA revisions. It seems that the need for a secondary patellar replacement in unreplaced cases was balanced by the need for revisions of failed patellar components in patellar replaced cases


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 649 - 656
1 Jun 2023
Dagneaux L Amundson AW Larson DR Pagnano MW Berry DJ Abdel MP

Aims

Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs.

Methods

Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m2 (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 128 - 135
1 Feb 2024
Jenkinson MRJ Cheung TCC Witt J Hutt JRB

Aims

The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR.

Methods

A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 109 - 116
8 Feb 2024
Corban LE van de Graaf VA Chen DB Wood JA Diwan AD MacDessi SJ

Aims

While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA.

Methods

A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1172 - 1177
1 Sep 2007
Benoit B Laflamme GY Laflamme GH Rouleau D Delisle J Morin B

We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all patellae were stable and knees functional with a mean Lysholm knee score of 98 points (95 to 100). In those aged younger than ten years at operation there was a statistically significant improvement in the sulcus angle at the latest follow-up (Student’s t-test, p = 0.001). Two patients developed asymptomatic patella infera as a late complication. This technique offers a satisfactory treatment for the immature patient presenting with habitual patellar dislocation associated with patella alta. If performed early, we believe that remodelling of the shallow trochlea may occur, adding intrinsic patellofemoral stability


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 66 - 66
1 Apr 2018
Chang C Yang C Chen Y Chang C
Full Access

For the management of displaced patellar fractures, surgical fixation using cannulated screws along with anterior tension band wiring is getting popular. Clinical and biomechanical studies have reported that using cannulated screws and a wire instead of the modified tension band with Kirschner wires improves the stability of fractured patellae. However, the biomechanical effect of screw proximity on the fixed construction remains unclear. The aim of this study was to evaluate the mechanical behaviors of the fractured patella fixed with two cannulated screws and tension band at different depths of the patella using finite element method. A patella model with simple transverse fracture [AO 34-C1] was developed; the surgical fixation consisted of two 4.0-mm parallel partial-threaded cannulated screws with a figure-of-eight anterior tension band wiring using a 1.25-mm stainless steel cable. Two different locations, including the screws 5-mm and 10-mm away from the leading edge of the patella, were used. A tension force of 850 N was applied on the patellar apexes at two loading angles (45° and 0° [parallel] to the long axis) to simulate different loading conditions while knee ambulation. The proximal side (base) of the patella was fixed, and the inferior articular surface was defined as a compression-only support in ANSYS to simulate the support from distal femur condyles. Compression-only support enables the articular surfaces of the present patella to only bear compression and no tension forces. Under different loading conditions, the fixed fractured patella yielded higher stability during 0° loading of tension force than during 45° loading. When the screws were parallel placed at the depth of 5 mm away from the patellar surface, the deformation of patellar fragment and maximum gap opening at the fracture site were smaller than those obtained by screws placed at the depth of 10 mm away from the patellar surface. Compared to the superficial screw placement, the deeper placement (10 mm) increased the maximum gap opening at the fracture site by 1.56 times under 45° loading, and 1.58 times under 0° loading. The load on the tension band wire of the 10-mm screw placement was 3.12 times (from 230 to 717 N) higher than that of the 5-mm placement. Under the wire, the contact pressure on the patellar surface was higher with the 10-mm screw placement than the 5-mm screw placement. The peak bone contact pressures with the 10-mm placement were 7.7 times (99.5 to 764 MPa) higher. This is the first numerical study to examine the biomechanical effects of different screw locations on the fixation of a fractured patella using screws and tension band. Based on a higher stability and lower cable tension obtained by the superficial screws placement, the authors recommended the superficial screw placement (5 mm below the leading edge of the patella) rather than the deep screws while fixing the transverse patellar fracture with cannulated screws and cable


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 126 - 126
1 Jun 2018
Berend K
Full Access

It is a not so uncommon clinical scenario: well-fixed, well-aligned, balanced total knee arthroplasty with continued pain. However, radiographs also demonstrate an unresurfaced patella. The debate continues and the controversy remains as whether or not to routinely resurface the patella in total knee arthroplasty. In perhaps the most widely referenced article on the topic, the overall revision rates were no different between the resurfaced (9%) and the unresurfaced (12%) groups and thus their conclusion was that similar results can be obtained with and without resurfacing. However, a deeper look in to the data in this study shows that 4 times more knees in the unresurfaced group were revised for patellofemoral problems. A more recent study concluded that selectively not resurfacing the patella provided similar results when compared to routinely resurfacing. The study does emphasise however, that this conclusion depends greatly on femoral component design and operative diagnoses. This suggests that selective resurfacing with a so-called “patella friendly” femoral component in cases of tibio-femoral osteoarthritis, is a safe and effective strategy. Finally, registry data would support routine resurfacing with a 2.3 times higher relative risk of revision seen in the unresurfaced TKA. Regardless of which side of the debate one lies, the not so uncommon clinical scenario remains; what do we do with the painful TKA with an unresurfaced patella. Precise and accurate diagnosis of the etiology of a painful TKA can be very difficult, and there is likely a strong bias towards early revision with secondary patellar resurfacing in the painful TKA with an unresurfaced TKA. At first glance, secondary resurfacing is associated with relatively poor outcomes. Correia, et al. reported that only half the patients underwent revision TKA with secondary resurfacing had resolution of their complaints. Similarly, only 53% of patients in another series were satisfied with the procedure and pain relief. The conclusions that can be drawn from these studies and others are that either routine patellar resurfacing should be performed in all TKA or, perhaps more importantly, we need to better understand the etiology of pain in an otherwise well-aligned, well-balanced, well-fixed TKA. It is this author's contingency that the presence of an unresurfaced patella leads surgeons to reoperate earlier, without truly identifying the etiology of pain or dissatisfaction. This strong bias; basically there is something more that can be done, therefore we should do it, is the same bias that leads to early revision of partial knee arthroplasty. While very difficult, we as knee surgeons should not revise a partial knee or secondarily resurface a patella due to pain or dissatisfaction. Doing so, unfortunately, only works about half the time. The diagnostic algorithm for evaluating the painful, uresurfaced TKA includes routinely ruling out infection with serum markers and an aspiration. Pre-arthroplasty radiographs should be obtained to confirm suitability and severity of disease for an arthroplasty. An intra-articular diagnostic injection with Marcaine +/− corticosteroid should provide significant pain relief. MARS MRI may be beneficial to evaluate edema within the patella. Lastly, operative implant stickers to confirm implant manufacturer and type are critical as some implants perform less favorably with unresurfaced patellae. To date, no studies of secondary resurfacing describe the results of this, or similar, algorithms for defining patellofemoral problems in the unresurfaced TKA and therefore it is still difficult to conclude that poor results are not simply due to our inherent bias towards early revision and secondary resurfacing of the unresurfaced patella


Bone & Joint Research
Vol. 11, Issue 7 | Pages 484 - 493
13 Jul 2022
Hayer S Niederreiter B Kalkgruber M Wanic K Maißner J Smolen JS Aletaha D Blüml S Redlich K

Aims

Insufficient treatment response in rheumatoid arthritis (RA) patients requires novel treatment strategies to halt disease progression. The potential benefit of combination of cytokine-inhibitors in RA is still unclear and needs further investigation. To explore the impact of combined deficiency of two major cytokines, namely interleukin (IL)-1 and IL-6, in this study double deficient mice for IL-1αβ and IL-6 were investigated in different tumour necrosis factor (TNF)-driven inflammatory bone disorders, namely peripheral arthritis and sacroiliitis, as well as systemic bone loss.

Methods

Disease course, histopathological features of arthritis, and micro-CT (µCT) bone analysis of local and systemic bone loss were assessed in 15-week-old IL1-/-IL6-/-hTNFtg in comparison to IL1-/-hTNFtg, IL6-/-hTNFtg, and hTNFtg mice. µCT bone analysis of single deficient and wild-type mice was also performed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 81 - 81
1 May 2016
Trieb K
Full Access

Introduction. Presentation of our outcome in implant survival and clinical function using rotating-hinge knee prosthesis in revision total knee arthroplasty. Method. A retrospective review of 44 revision TKA containing 21 RHK (Biomet) and 23 MRH (Stryker). The patient population consisted of 27 women and 17 men with an average age of 75 years at the time of the revision. The mean follow-up period was 13 months. The clinical and functional results were evaluated according to the Knee-Society-Score (KSS) after 3, 6, 12, 24 and 36 months together with a x-ray. Results. The indication for the revision included aseptic loosening and ligamentous instability, 6 times as primary total knee replacement, an infected total knee in 6 cases and fractures with severe bone defect in 4 cases. The KSS pain improved from 49 (range 23–70) to 76 (range 34–98). The KSS function did not show any significant improvement of 60 (range 10–55) to 65 (range 20–100). The ROM improved with 53% from 74 (range 50–110) to 113 (range 65–130). Our complications have been revisions of hematoma in 4 cases, an infection/recurrence of infection in 2 cases with following explantation. There were 3 ligamentum patellae ruptures, 2 times due to rheumatoid arthritis, once due to Mb. Parkinson. We noticed 2 cases with peronaeus paresis (once temporarily) and one Guillain-Barre-Syndrom. With our x-rays we observed radiolucent lines without any progression or loosening factor for the prosthesis. Conclusion. We have seen good results using RHK and MRH in function and particularly a very good stability even for loss of collateral ligaments or massive bone loss. We evaluated a reduction of pain and an improvement of ROM although we had a number of revisions because of infection and co-morbidities


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 47 - 47
1 May 2016
Spangehl M Fraser J
Full Access

Introduction. Patellar resurfacing is performed in more than 90% of primary total knee arthroplasties (TKAs) in the United States, yet far fewer patellae are resurfaced internationally. Multiple randomized controlled trials have shown decreased revision rates in patients with resurfaced patellas (RP) vs. non-resurfaced (NR). However, most of these studies showed no difference in patient satisfaction, anterior knee pain, or knee society scores. (Figure 1) Given uncertain benefits, the purpose of this study was to determine if the rates of patellar resurfacing have changed over the past 10 years worldwide. Methods. Data was obtained via direct correspondence with registry administrators or abstracted from the annual reports of six national joint registries: Australia, Denmark, England, New Zealand, Norway, and Sweden. Rates of patellar resurfacing between 2003 and 2013 were collected. Where data was available, subgroup analysis was performed to examine revision rates among RP and NR TKAs. Results. The average rates of patellar resurfacing from 2003 to 2013 ranged from 5% (Norway) to 71% (Denmark). Three countries showed a decreased rate of patellar resurfacing over this time period while two demonstrated an increase. The largest decrease in resurfacing rates was in Sweden (15% to 2%), while the biggest increase was in Australia (44% to 53%). (Figure 2) In 2010, 48,367 of 137,813 (35%) primary TKAs from all six countries were resurfaced. (Figure 3) Among RP and NR TKAs, Australia documented a 10-year cumulative revision rate (CRR) of 4.9% and 6.0%, respectively. Sweden showed a 10-year CRR of 4% in both groups. Conclusion. While not all national joint registries report rates of patellar resurfacing, it is clear that most countries outside of the US continue to resurface a much smaller proportion of patellas in primary TKA. Worldwide, the rates of patellar resurfacing have changed little in the past decade


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 51 - 51
1 Nov 2015
Barrack R
Full Access

BACKGROUND. Patella resurfacing in TKA remains controversial. The purpose of this study was to compare the long-term clinical outcome in TKA in patients undergoing bilateral TKAs with one patella resurfaced and the other patella nonresurfaced. METHODS. Twenty-nine patients (58 knees) underwent primary bilateral TKA for osteoarthritis. These patients were enrolled in a prospective randomised double blinded study and represent a subset of a larger study of patella resurfacing. All patients received the same posterior cruciate sparing TKA. Patients each had one knee randomised to treatment with or without patella resurfacing. The contralateral knee then received the alternative patellar treatment, such that all patients had one knee with a resurfaced patella and the other nonresurfaced. Clinical evaluations consisted of routine radiographic and clinical follow-up and included with a Knee Society Score patellofemoral specific patient questionnaire. Twenty-eight patients (56 knees) participated and were followed for a mean of 118 months (range, 69–146 months). RESULTS. There were no significant differences between the knees treated with and without patellar resurfacing with regard to range of motion, KSCRS, or the pain and function scores. Forty-six percent (13/28 patients) of patients preferred the resurfaced knee, 36% (10/28) the nonresurfaced knee, and 18% (5/28) had no preference. Two patients (7%) in the nonresurfaced group required revision for a patellofemoral related complication, compared to one patient (3.5%) in the group with a resurfaced patella. CONCLUSIONS. Ten year follow-up reveals equivalent results for resurfaced and nonresurfaced patellae in TKA with regards to ROM, KSCRS, pain and function, or patellofemoral symptoms. In this large series of bilateral TKAs, 64% of patients either preferred the unresurfaced knee or had no preference


Bone & Joint Research
Vol. 11, Issue 1 | Pages 23 - 25
17 Jan 2022
Matar HE Platt SR Bloch BV Board TN Porter ML Cameron HU James PJ


Bone & Joint Open
Vol. 3, Issue 1 | Pages 12 - 19
3 Jan 2022
Salih S Grammatopoulos G Burns S Hall-Craggs M Witt J

Aims

The lateral centre-edge angle (LCEA) is a plain radiological measure of superolateral cover of the femoral head. This study aims to establish the correlation between 2D radiological and 3D CT measurements of acetabular morphology, and to describe the relationship between LCEA and femoral head cover (FHC).

Methods

This retrospective study included 353 periacetabular osteotomies (PAOs) performed between January 2014 and December 2017. Overall, 97 hips in 75 patients had 3D analysis by Clinical Graphics, giving measurements for LCEA, acetabular index (AI), and FHC. Roentgenographical LCEA, AI, posterior wall index (PWI), and anterior wall index (AWI) were measured from supine AP pelvis radiographs. The correlation between CT and roentgenographical measurements was calculated. Sequential multiple linear regression was performed to determine the relationship between roentgenographical measurements and CT FHC.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1057 - 1061
1 Dec 2021
Ahmad SS Weinrich L Giebel GM Beyer MR Stöckle U Konrads C

Aims

The aim of this study was to determine the association between knee alignment and the vertical orientation of the femoral neck in relation to the floor. This could be clinically important because changes of femoral neck orientation might alter chondral joint contact zones and joint reaction forces, potentially inducing problems like pain in pre-existing chondral degeneration. Further, the femoral neck orientation influences the ischiofemoral space and a small ischiofemoral distance can lead to impingement. We hypothesized that a valgus knee alignment is associated with a more vertical orientation of the femoral neck in standing position, compared to a varus knee. We further hypothesized that realignment surgery around the knee alters the vertical orientation of the femoral neck.

Methods

Long-leg standing radiographs of patients undergoing realignment surgery around the knee were used. The hip-knee-ankle angle (HKA) and the vertical orientation of the femoral neck in relation to the floor were measured, prior to surgery and after osteotomy-site-union. Linear regression was performed to determine the influence of knee alignment on the vertical orientation of the femoral neck.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 89 - 89
1 May 2016
Megahed R Stocks O Ismaily S Stocks G Noble P
Full Access

Introduction. The success of knee replacement surgery depends, in part, on restoration of the correct alignment of the leg with respect to the load-bearing vector passing from the hip to the ankle (the mechanical axis). Conventional thinking is that the correct angle of resection of the distal femur (Valgus Cut Angle, VCA) depends on femoral length or femoral offset, though femoral bowing, in addition to length and medial offset, may also have a significant influence on the VCA. We hypothesized that femoral bowing has a strong effect on the VCA necessary to restore physiologic alignment after arthroplasty or osteotomy. Methods. A total of 102 long-leg radiographs were obtained from patients scheduled for primary total knee arthroplasty. The patients on average were 41% male 59% female, 67.9 ± 11.1 years, 67.0 ± 4.7 in, 192 ± 43 lbs, and had a BMI of 29.7 ± 4.8. All radiographs were prepared with the feet placed in identical rotation and the patellae pointing forward, and were excluded if there was evidence of malrotation, as defined by (i) a difference in the medial head offsets of the right and left femur of >3mm, (ii) a difference in the width of the tibiofibular syndesmoses, or (iii) a difference in the rotation of one foot compared to the other. The following anatomic variables were measured on each radiograph: (i) the neck shaft angle (NSA) of the femur, (ii) the length of the femur, (iii) the length of the femoral shaft, (iv) the medial head offset, (v) the medial-lateral bow of the distal femur, (vi) the hip- knee axis angle, (vii) the mechanical axis deviation of the extremity at the knee, (viii) the medio-lateral bow of the tibia, and (ix) the valgus cut angle required to restore the mechanical axis to the center of the knee during surgery (VCA). Bivariate plots were constructed using the measurements thought to influence the VCA: femoral bowing, femoral offset, and length of femur. Multivariate regression was then used to find the variable that had the strongest effect on the VCA. Results. The bivariate plot of offset and VCA yielded an R2 of 0.02544 (p = 0.11) was not statistically significant. However, the bivariate plot of femoral length and VCA yielded an R2 of 0.1294 (p = 0.0002) showing significant correlation. Lastly, the bivariate plot of femoral bowing and VCA yielded an R2 of 0.59136 (p < 0.00001) demonstrating significant correlation (Figure 3). Multivariate analysis revealed that femoral bowing was the best predictor of VCA: VCA = 5.46–0.363 femoral bowing (°) + 0.106 Femoral offset (mm) − 0.010 femoral length (mm). Discussion. While clinicians performing knee replacements typically do not consider femoral bowing when selecting the valgus angle appropriate for each patient, our findings demonstrate that femoral bowing has a potent effect on VCA. The multivariate regression indicated that femoral bowing had the highest effect on VCA followed by offset and femoral length. These findings suggest that surgeons should consider measuring long alignment radiographs before performing a total knee arthroplasty


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 1 - 1
1 Aug 2013
Barrow M
Full Access

Purpose of Study:. Various techniques have been described and are still used for treating recurrent dislocation of the patella when conservative measures fail. Among them are distal, proximal and combined realignment techniques and lateral releases. Since being shown proof of the biomechanical importance of the medial patellofemoral ligament (MPFL) in patellofemoral instability, the reconstruction of the MPFL has gained in popularity. The objective of this paper is to present a case series with preliminary clinical results using the gracilis tendon to reconstruct the MPFL. Method:. Between 01/07 and 03/11 23 knees in 21 patients underwent reconstruction of the MPFL.4 of these patients had had previous surgery. Preoperatively the Caton Deschamps ratio using plain x-rays was worked out and the TT/TG distance was measured using CT scanning. Using these measurements as a guideline, 7 cases underwent a tibial tubercle transfer as an additional procedure. In 6 of the cases an additional cartilage procedure was required. The technique was simplified using intra-operative x-rays to achieve anatomical tunnel placement. Results:. The Tegner Activity Score was used to evaluate the patients preoperatively and at a minimum of 6 months postoperatively. The scores improved on average from 3,6 to 7,4. One patient had an extensor lag of 10 degrees at 3 months. This had normalised by 6 months. One patient had recurrence of her instability and required a revision MPFL reconstruction using an allograft. One patient had recurrent episodes of patella subluxation but no overt dislocation. Conclusion:. This case series gave good functional results using the Tegner Activity score. The procedure of MPFL reconstruction was effective in stabilising the patellae and in improving the symptoms of patellofemoral instability


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1736 - 1741
1 Nov 2021
Tolk JJ Eastwood DM Hashemi-Nejad A

Aims

Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths.

Methods

All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total leg length, femoral and tibial length, articulotrochanteric distance (ATD), and subtrochanteric femoral length were compared between PD side and the unaffected side. Furthermore, we compared leg length measurements between patients who did and who did not have a contralateral epiphysiodesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 454 - 456
1 Nov 1980
Waisbrod H Treiman N

We have performed intra-osseous venography on 22 patients with chondromalacia patellae or patellofemoral osteoarthritis. Venous engorgement of the patella was demonstrated in both conditions regardless of the severity of the pathological changes


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 105 - 105
1 Jan 2016
Onishi Y Ishimaru M Hino K Shiraishi Y Miura H
Full Access

Introduction. MERA Quest Knee System (Quest Knee) is a posterior cruciate ligament–retaining prosthesis considering the anatomical features and lifestyles of the Japanese. As for the anatomical features, we reduced the size of prosthesis and set a smaller interval of sizes because Japanese knees are smaller and flatter than those of Caucasians. As for the lifestyles, we evaluated in vivo patellar tracking during deep knee flexion and the condylar geometry in the axial plane of magnetic resonance imaging. It was found that the patella sank deeply into the intercondylar notch and that the articular surface of the lateral condyle began to curve steeply. We adopted this shape and engraved the lateral condyle deep to reduce the pressure of the patellofemoral joint and to get better range of motion (ROM). For the contact pressure rise in the femorotibial joint by engraving the lateral condyle, the insert was suited to the shape of the femoral component. Furthermore, we increased the thickness of the posterior flange of the femoral component and changed the posterior radius of curvature gradually, and this shape allowed the flexion of 155°. We have used Quest Knee for clinical applications from October 2009. We studied the short-term results of Quest Knee. Methods. Between June 2010 and July 2013, the same senior surgeon performed 59 consecutive primary operations with Quest Knee. Forty patients (44 knees) were women, and 14 patients (15 knees) were men. The mean patient age was 72.5 years (range, 59–89 years). All were osteoarthritis knees. Coronal deformity was varus in 58 knees and valgus in one knee. All operations were performed with a measured resection technique, and all patellae were resurfaced. Clinical evaluations were assessed using the Japanese Orthopaedic Association knee rating score (JOA score), and clinical ROM and standing femorotibial angle (FTA) were measured. Additionally, three-dimensional motion analysis of the patellar component during squatting was performed by the image matching method with image correlations. Results. The mean follow-up period was 17.4 months (range, 6–43 months). The JOA score at preoperative and follow-up were 57.5 ± 10.1 and 87.5 ± 5.6 points, respectively (P < 0.0001) (Fig. 1). The ROM at preoperative and follow-up were 127.4 ± 11.1 and 126.2 ± 9.0° (P = 0.47) (Fig. 2). The mean FTA at preoperative and follow-up were 184.2 and 172.3°. With regard to the three-dimensional motion analysis, the patella showed lateral shift during squatting (Fig. 3). Discussion. As for the patellofemoral contact pressure at flexion in total knee arthroplasty, a biomechanical study has reported that the pressures of posterior cruciate ligament–retaining and posterior-stabilized knees were 3.2 and 2.8 times as much as the body weight. This report suggests that the reduction of the pressure of the patellofemoral joint during deep knee flexion results in better ROM. We suppose that Quest Knee reduced the pressure, led the patella to the lateral side, and achieved better ROM. Conclusions. Short-term results of Quest Knee were good. More detailed studies are needed to get better function and long-term durability


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 63 - 65
1 Jan 1996
Dellestable F Péré P Blum A Régent D Gaucher A

We describe a syndrome combining abnormalities of the pelvis, knee and foot in three related patients with a familial history of small dislocated patellae. The clinical and radiological appearance of the patella and pelvis is consistent with the ‘small-patella’ syndrome, a rare autosomal dominant disorder. There were also previously unreported deformities affecting the feet


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 448 - 451
1 Aug 1983
Levai J McLeod H Freeman M

The results of resurfacing or not resurfacing the articular cartilage of the patella were reviewed in 71 knees--47 with rheumatoid arthritis and 24 with osteoarthritis--which had been replaced with the ICLH prosthesis. Two rheumatoid and osteoporotic patellae developed transverse fractures with separation and were excluded from the review. The results showed that resurfacing the patella greatly reduced peripatellar pain with no counter-balancing disadvantage


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 2 | Pages 172 - 175
1 May 1979
Scott J Taor W

Twelve closely related members of one family were found to have small or absent patellae. Seven of these patients also had abnormalities of the pelvic girdle and upper femora. There was a resemblance to the nail--patella syndrome in the patellar abnormalities but not in the associated conditions, and it would therefore appear that the syndrome described is a new variety of congenital abnormality of the knee


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 2 - 2
1 Jul 2012
Jones MA Newell C Howard PW
Full Access

Purpose. To establish the reliability of reporting and recording revision hip and knee arthroplasties by comparing data in the National Joint Registry (NJR), Hospital Episode Statistics (HES) and our local theatre records. Methods. The paper theatre registers for all orthopaedic theatres in the Royal Derby Hospitals NHS Trust were examined for details of revision hip and knee replacements carried out in 2007 and 2008. This was then cross-checked and merged with the local electronic theatre data to obtain a definitive local record of all revision hip and knee arthroplasties. Data for the same period was requested from the NJR and HES and these data were checked against our definitive local record for discrepancies. The HES codes used were the same codes used to compile the recent NJR annual reports. Results. The theatre registers and ORMIS identified 271 revision hip and knee arthroplasties in the study period. The NJR had corresponding data for 176 (65%) of these, and HES had 250 (92%). 10 cases (4%) were not recorded by either NJR or HES: 8 secondary resurfacings of patellae and 2 posterior lip augmentations in hips. Of those operations “missed” by HES, most had been assigned a correct “W” code, but had a “Y” or “Z” OPCS code not used in the NJR annual reports. Conclusion. When HES and the NJR data are combined, they are an accurate representation of real practice. More robust methods of reporting revision arthroplasty to the NJR are required. The OPCS codes used to indicate a revision need to be reviewed


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 34 - 36
1 Jan 1999
Matsumoto H Kawakubo M Otani T Fujikawa K

Two men, aged 21 and 50 years, were seen with ossification of the patellar tendon after injury to the knee in adolescence. They complained of pain and had patella alta. Large bony masses were excised from below the affected patellae. The patellar tendon was then reconstructed using a Leeds-Keio ligament. The results at six and ten years, respectively, were good, with neither patient having pain or an extension lag


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 452 - 452
1 Apr 2004
Schepers A van der Jagt D Kumasamba J
Full Access

Anterior knee pain after total knee arthroplasty (TKA) occurs in 5% to 30% of patients whether or not the patella has been resurfaced. We retrospectively reviewed our patients, none of whom underwent patellar resurfacing. Only 2% had anterior knee pain, none requiring revision surgery. Our follow-up was between two and five years. We paid particular attention to removing osteophytes and conducting a thorough peripatellar synovectomy and a circumpatellar cautery denervation. Our results compare favourably to those in the literature, whether or not the patellae were resurfaced. We conclude that patellar resurfacing in TKA is unnecessary when careful attention is paid to the peripatellar tissues


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1505 - 1513
1 Sep 2021
Stockton DJ Schmidt AM Yung A Desrochers J Zhang H Masri BA Wilson DR

Aims

Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters.

Methods

An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended.


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 483 - 487
1 Aug 1971
Dandy DJ

1. Eight patients are described in whom the patellae subluxated laterally on every extension of the knee. This is an unusual type of recurrent subluxation. It may recover completely, or remain symptom-free for many years, or increase in severity so that the patient seeks treatment for relief of pain and joint effusion, or progress to frank dislocation. 2. Each patient was examined and the probable causes were analysed. The bayonet deformity was present in twelve of the sixteen knees. A new observation is made on the relationship of tibial crest and tubercle in this condition


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 328 - 328
1 Jul 2014
Hargrave-Thomas E Thambyah A McGlashan S Broom N
Full Access

Summary. Macroscopic grading, histologic grading, morphometry, mineral analysis, and mechanical testing were performed to better understand the changes that occur in the cartilage, calcified cartilage, and subchondral bone in early osteoarthritis. Introduction. The earliest changes in osteoarthritis (OA) remain poorly understood due to the difficulty in detecting OA before patients feel pain. We have published details of the mature bovine patella model showing the pre-OA state where no gross macroscopic changes are visible yet microstructural changes indicate very early degeneration. In this new study, we proceed to investigate this model further by more comprehensively quantifying the changes in articular cartilage (AC), zone of calcified cartilage (ZCC), and subchondral bone (SB) in pre and early OA. Methods. Patellae from mature cow were studied. Gross examination with India ink was used to classify macroscopic cartilage degeneration. Two groups were selected in this study: one with no visible surface degeneration (pre-OA) and the other with mild to moderate macroscopically visible surface degeneration (early OA). Histologic staining with Safranin O and Fast Green was analysed with two osteoarthritic scoring systems: Mankin and OOCHAS. Differential Interference Contrast (DIC) microscopy was used to quantify morphometric changes. Degree of mineralisation was analysed with energy dispersive X-ray spectroscopy (EDS) to quantify the calcium and phosphorus content of the mineralised tissues. Material properties of calcified cartilage and subchondral bone were tested macroscopically using 3 point bending. Results. In the early OA group, cartilage was fissured and showed matrix loss. In its hydrated state, average cartilage thickness was significantly greater (p<0.05) in the early OA group by 24% compared to pre-OA group. The early OA group showed an 88% increase in ZCC thickness. Early OA tissue was graded significantly higher in OOCHAS grading and structure scores, cellularity, and staining scores of Mankin grading but not in the tidemark integrity score. Pre-OA and early OA tissues showed no significant differences in ZCC or SB mineralisation although all samples showed an increase in the degree of mineralisation going from the upper to the deeper ZCC and SB. Macroscopic mechanical testing showed no significant differences in mechanical properties between pre-OA and early OA groups. However within groups, the ZCC was an order of magnitude less stiff than the SB. Micromechanical testing showed that deeper ZCC and SB were stiffer than their regions closer to the joint surface. Conclusions. Early osteoarthritic changes in the joint tissues produce macro-level cartilage degeneration as well as microstructural changes. The combination of mineralisation and mechanical data show that though calcified cartilage and subchondral bone have similar mineralisation profiles, their material properties are drastically different, suggesting that stiffness is not purely the result of the mineral phase


Background. Autologous chondrocyte implantation (ACI) and mosaicplasty (MP) are two methods of repair of symptomatic articular cartilage defects in the adult knee. This study represents the only long-term comparative clinical trial of the two methods. Methods. A prospective, randomised comparison of the two modalities involving 100 patients with symptomatic articular cartilage lesions was undertaken. Patients were followed for ten years. Pain and function were assessed using the modified Cincinnati score, Bentley Stanmore Functional rating system and visual analogue scores. ‘Failure’ was determined by pain, a poor outcome score and arthroscopic evidence of graft disintegration. Results. Patients had a mean age at index operation of 31. There was a long mean pre-op duration of symptoms of seven years and the defects had an average of 1.5 operations (excluding arthroscopy) to the articular cartilage lesion prior to the cartilage repair surgery. The aetiology of the articular cartilage defects was mainly trauma; some patients had osteochondritis dissecans or chondromalacia patellae. Five patients were lost to follow-up. A total of 23 out of 42 mosaicplasty patients failed, 10 out of 58 ACI patients failed (p<0.001). Most patients did well for the first two years when there was a steep failure of mosaicplasty patients, after which the failure rate was more constant. There was a low steady failure rate of ACI over the 10 years. Older patients treated by ACI did worse than younger patients; age was less of a prognostic indicator in MP. Patients irrespective of gender or aetiology of the defect fared better with ACI than MP. Conclusion. At ten years, patients who underwent cartilage repair using ACI fared significantly better than those who underwent mosaicplasty