Three hundred and nineteen patients who had chondromalacia
1. It is suggested that abruptness of the condylar ridges on the femur plays a major role in the etiology of chondromalacia
Objectives. To assess the effectiveness of a modified tibial tubercle osteotomy
as a treatment for arthroscopically diagnosed chondromalacia
1. The occurrence of bilateral double-layer
Full thickness samples of articular cartilage were removed from areas of chondromalacia on the medial and "odd" facets of the
Six cases of osteochondritis dissecans
Four methods of surgical treatment of chondromalacia
1 . Current theories of the etiology of chondromalacia
Minor degrees of malalignment of the patella and anatomical abnormalities including a flattened sulcus angle and an increased ratio between patellar tendon length and patellar length (PT:P) have been suggested as predisposing factors in the causation of chondromalacia
A new radiological technique is presented in which serial axial radiographs of the patellofemoral joints are taken under conditions in which the muscles about the knee and hip are contracted in a manner similar to that during weight-bearing. A form of analysis has been developed whereby patellar rotation can be measured in two planes and femoral rotation about its long axis inferred. A population of asymptomatic adults and children was investigated in this way and their results (regarded as normal) compared with those in fifteen children with idiopathic chondromalacia
This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates. A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.Aims
Methods
The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.Aims
Methods
1. Chondromalacia of the patella starts most frequently on the medial facet. 2. The anatomy of the medial femoral condyle is described, including the rim at its superior border, and the different arrangement at the upper border of the lateral femoral condyle. 3. Rubbing of the medial patellar facet on the rim at the upper border of the medial femoral condyle can explain in part the etiology of chondromalacia.
The articular cartilage of the patella was studied in 100 knees at necropsy. In twenty-one of these knees the cartilage changes were related to the trabecular architecture of the underlying bone. It would appear that the initiation and location of cartilage damage and its rate and degree of progression are related to the relative stiffness of the underlying cancellous bone. On the basis of our observations we suggest that the diagnosis "chondromalacia of the patella" should be reserved for patients with asymptomatic or transiently symptomatic fibrillation of the articular cartilage of the central medial patellar facet. Those patients with persistent patellofemoral pain should be considered to have some other syndrome.
The purpose of this prospective and randomized study was to objectively evaluate isokinetic strength, clinical, and radiographical outcome in bilateral TKA using the same prosthesis with and without patella resurfacing. Bilateral TKA, one with, one without patella resurfacing was performed in 22 osteoarthritic patients, mean age was 68 years using the Low-Contact-Stress prosthesis. Minimum Follow-up was one year. Evaluation included clinical investigation, specific patella scores, radiographic analysis and isokinetic strength measurement of both knee flexion and extension at 60 degrees per second (Biodex). surement at 60 degrees per second (Biodex). There was no significant clinical score difference, but mean isokinetic strength of knee extension was significantly (p<
.0001) stronger in the non-resurfaced patella TKA (40.5 Nm) compared with the resurfaced TKA (38,5 Nm). Flexion was also significantly stronger in the patella non-resurfaced group with 22.4 Nm versus 19.5 Nm in the resurfaced group. Mean lateral deviation was significantly (p<
.001) less ideal in the resurfaced group as was postoperative patellofemoral congruent contact (p<
.001). However, there was no correlation between lateral patella deviation or congruent contact and iso-kinetic strength. The results of this study indicate that mean isokinetic strength of both knee flexion and extension was significantly stronger in the non-resurfaced patella TKA. This study provides encouraging data for patella non-resurfacing. However, clinical scores or patient’s preference did not show any difference.
Two distinct lesions affect the articular cartilage of the patella. Surface degeneration occurs particularly on the odd facet; it is age dependent, often present in youth and it becomes more frequent with increasing age. It probably does not occasion patello-femoral pain in youth, but may predispose to degenerative arthritis in that joint in later years and is regarded as a consequence of habitual disuse. The term "basal degeneration" is used to describe a lesion in which there is a fasciculation of collagen in the middle and deep zones of cartilage without, at first, affecting the surface. It was found astride the ridge separating the medial from the odd facet in twenty-three adolescents who had complained of prolonged patello-femoral pain. They were treated by excision of the disc of affected cartilage, with relief of pain in most cases. The pathogenesis of basal degeneration is related to the functional anatomy of the patella.
Lateralisation of the tuberosity tibia causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking patella (LTP), resulting in anterior knee pain, or objective patellar instability (OPI), resulting in recurrent luxations. For a precise preoperative diagnosis the tuberositas tibia (TT) trochlear groove (TG) distance was measured on a CT scan. A distance of more than 15 mm was considered to be pathological. In a prospective study, the clinical results of a subtle, CT-guided medial tuberosity transfer for LTP and OPI were evaluated. 30 Consecutive patients with LTP and 30 patients with OPI and an increased TT TG were included. Outcomes were documented at 3, 12 and 24 months follow-up using the Lysholm scale, the Kujala score, and a visual analogue pain score. Postoperatively all but one patient reported good improvement in stability (no persistent subluxations or luxations). All patients had a marked improvement in pain and functional scores at follow up. Complications seem to be related to the peroperative technique. CT-guided TT transfer appears to be satisfactory and safe method for treating patients with an increased TT TG leading to either LTP or OPI.
Abstract. Objectives. The aim of this study was to develop an in vitro GAG-depleted patella model and assess the biomechanical effects following treatment with a SAP:CS self-assembling hydrogel. Methods. Porcine
Introduction. Patella implant research is often overlooked despite its importance as the third compartment in a total knee replacement. Wear and fracture of resurfaced
Abstract. Introduction. Osteoarthritis (OA) is one of the lead causes of pain and disability in adults. Bone marrow lesions (BMLs) are one feature of subchondral bone involvement in OA. MRI images suggest changes in tissue content and properties in the affected regions however, it is not known if this alters the mechanical behavior of the bone, which could in turn affect OA progression. The aim of this study was to characterize the mechanical properties of BMLs, using a combined experimental and computational approach. Methods. Six human cadaveric
Osteoarthritis (OA) is a disease that affects both bone and cartilage. Typically, this disease leads to cartilage degradation and subchondral bone sclerosis but the link between the two is unknown. Also, while OA was traditionally thought of as non-inflammatory condition, it now seems that low levels of inflammation may be involved in the link between these responses. This is particularly relevant in the case of Post-Traumatic OA (PTOA), where an initial phase of synovial inflammation occurs after injury. The inflammatory mediator interleukin 1 beta (IL-1B) is central to this response and contributes to cartilage degradation. However, whether there is a secondary effect of this mediator on subchondral bone, via bone-cartilage crosstalk, is not known. To address this question, we developed a novel patellar explant model, to study bone cartilage crosstalk which may be more suitable than commonly used femoral head explants. The specific aim of this study was to validate this novel patellar explant model by using IL-1B to stimulate the inflammatory response after joint injury and the subsequent development of PTOA. Female Sprague Dawley rats (n=48) were used to obtain patellar explants, under an institutional ethical approval license.
Introduction. Experimental wear simulation of an all-polymer knee implant has shown an equivalent rate of wear of UHMWPE tibial components against PEEK-OPTIMA™ and cobalt chrome femoral components of a similar initial geometry and surface topography. However, when the patella is resurfaced with an UHMWPE patella button, it is important to also ascertain the wear of the patella. Wear debris from the patella contributes to the total volume of wear debris produced by the implant which should be minimised to reduce the potential for osteolysis and subsequent implant loosening. The aim of this study was to investigate the wear of the patellofemoral joint in an all-polymer knee implant. The wear of UHMWPE
Abstract. Background. Accurate analysis of the patellar resurfacing is essential to better understand the etiology of patella-femoral problems and dissatisfaction following total knee arthroplasty (TKA). In the current published literature patellar resurfacing is analysed using 2D radiographs. With use of radiographs there is potential for error due to differences in limb positioning, projection, anatomic variability and difficulties in appreciating the cement-bone interface. So, we have developed a CT Scan based 3D modelled technique for accurate evaluation of patellar resurfacing. Methods. This technique for analyses of patellar resurfacing is based on the pre-operative and pos-operative CT Scan data of the patients who underwent TKA with patellar resurfacing. In the first step, accurately landmarked 3D models of pre-op
Introduction and Objective. Traditionally, osteoarthritis (OA) has been associated mostly with degradation of cartilage only. More recently, it has been established that other joint tissues, in particular bone, are also centrally involved. However, the link between these two tissues remains unclear. This relationship is particularly evident in post-traumatic OA (PTOA), where bone marrow lesions (BMLs), as well as fluctuating levels of inflammation, are present long before cartilage degradation begins. The process of bone-cartilage crosstalk has been challenging to study due to its multi-tissue complexity. Thus, the use of explant model systems have been crucial in advancing our knowledge. Thus, we developed a novel patellar explant model, to study bone cartilage crosstalk, in particular related to subchondral bone damage, as an alternative to traditional femoral head explants or cylindrical core specimens. The commonly used osteochondral explant models are limited, for our application, since they involve bone damage during harvest. The specifics aim of this study was to validate this novel patellar explant model by using IL-1B to stimulate the inflammatory response and mechanical stimulation to determine the subsequent developments of PTOA. Materials and Methods. Lewis rats (n=48) were used to obtain patellar and femoral head explants which were harvested under an institutional ethical approval license. Explants were maintained in high glucose media (containing supplements), under sterile culture conditions. Initially, we characterised undamaged patellar explants and compared them with the commonly used femoral head. First, tissue viability was assessed using an assay of metabolic activity and cell damage. Second, we created chemical and mechanical damage in the form of IL-1B treatment, and mechanical stimulation, to replicate damage. Standard biochemical assays, histological assays and microstructural assays were used to evaluate responses. For chemical damage, explants were exposed to 10ng/ml of IL-1B for 24 hours at 0, 1, 3 and 7 days after harvesting. For mechanical damage, tissues were exposed to mechanical compression at 0.5 Hz, 10 % strain for 10 cycles, for 7 days. Contralateral
Introduction. The trochlea of a typical patellofemoral replacement or anterior flange of a total knee replacement usually extends past the natural trochlea and continues onto the femoral anterior cortex. One reason for this is that it allows a simple patella button to be permanently engaged in the trochlea groove in an attempt to ensure stability. On the natural patella, the apex helps to guide it into the trochlea groove as the knee moves from full extension into flexion. The aim is to study whether a generalised patella can be created that is close in form to a healthy patella. Method. MRI scans were taken of 30
Joint registries suggest a downward trend in the use of uncemented Total Knee Replacements (TKR) since 2003, largely related to reports of early failures of uncemented tibial and patella components. Advancements in uncemented design such as trabecular metal may improve outcomes, but there is a scarcity of high-quality data from randomised trials. 319 patients <75 years of age were randomised to either cemented or uncemented TKR implanted using computer navigation.
Introduction. The metal-backed patella was originally designed to address shortcomings found with cemented, all-polyethylene
Total knee replacements are being more commonly performed in active younger and obese patients. Fifteen-year survivorship studies demonstrate that cemented total knee replacements have excellent survivorship, with reports of 85 to 97%. Cemented knee arthroplasties are doomed to failure due to loss of cement-bone interlock over time. Inferior survivorship occurs in younger patients and obese patients who would be expected to place increased stress on the bone-cement interfaces. Roentgen stereophotogrammetric analysis (RSA) studies have indicated that cementless fixation should perform better than cemented fixation. However, cementless fixation for total knee replacement has not gained widespread utilization due to the plethora of poor results reported in early series. The poor initial results with cementless total knee replacement have occurred due to poor implant designs such as cobalt chrome porous interfaces, poor initial tibial component stability, lack of continuous porous coating, poor polyethylene, and use of metal-backed
Total knee replacements (TKRs) are being more commonly performed in active younger and obese patients. Fifteen year survivorship studies demonstrate that cemented total knee replacements have excellent survivorship, with reports of 85% to 97%. However, inferior survivorship occurs in younger patients and obese patients who would be expected to place increased stress on the bone cement interfaces. Cementless fixation for total knee replacement has not gained widespread utilization due to the plethora of poor results reported in early series. These poor results do not reflect that cementless fixation is not obtainable, since an almost universal acceptance of cementless fixation for total hip replacement has shown. A Cochrane database study of total knees with roentgen stereophotogrammetric analysis (RSA) demonstrated that the risk of future aseptic loosening should be 50% less with cementless fixation. The poor initial results with cementless total knee replacement have occurred due to poor implant designs such as cobalt chrome porous interfaces, poor initial tibial component fixation, lack of continuous porous coating, poor polyethylene, and use of metal-backed
Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese;
A high proportion of complications following TKR occur at the patellofemoral articulation secondary to delami-nation and adhesive/abrasive wear. Electron beam cross-linking and melting has been shown to substantially reduce delamination and adhesive/abrasive wear in polyethylene tibial inserts. A series of in-vitro patella wear and fatigue tests were developed to explore the benefits of this material at the patellofemoral articulation.
Resurfacing the patella is performed the majority of the time in the United States and in many regions it is considered standard practice. In many countries, however, the patella is left un-resurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine rather more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced
Introduction: Patellar complications after total knee arthroplasty (TKA) remain a common reason for failure. Fully congruent patellar components, with larger contact areas and a polyethylene articular surface that is free to rotate in the frontal plane (LCS design), were designed to accommodate patellar mechanics and decrease wear. However, it remains to be determined whether the perceived advantages of a mobile-bearing, fully congruent patella design are realized in-vivo. The purpose of this study is correlate wear patterns on congruent mobile-bearing patellar components with patellar mechanics that existed after TKA. Methods: Uncemented metal-backed patellar components were retrieved at revision surgery from 26 knees with meniscal bearing (23 knees) and rotating platform (3 knees) LCS mobile bearing prostheses (DePuy Orthopaedics). Mean patient age and time in-situ was 75+11 years and 11+4 years, respectively. Revision reasons included bearing wear (11), patella wear (7), instability (2), pain (3), loosening (1), osteolysis (1), and unknown (1). Polyethylene damage was assessed using optical microscopy. Articular wear area was measured using digital image analysis and the % area, location and incidence of each damage mode was calculated. Results: The average damage area on the retrieved patella occupied 69%+15% of the surface. Burnishing, delamination and scratching modes occupied the largest areas. Delamination was noted on 58% of the retrieved
INTRODUCTION: Following Total Knee Arthroplasties, patellofemoral complications have shown to be responsible for approximately 50% of re-operations. Contemporary patellar designs employ both “onlay” and “inset” configurations. The latter promotes ease of placement, reduced bone removal and a heralded theoretic advantage of increased strength at the fixation interface. However, to date, no reports have compared the disassociation strengths of these two patellar component modes of fixation. The purpose of this study is to quantify the shear disassociation strength for both onlay and inset patellar fixation techniques. METHODS: Two sets of synthetic solid foam
Resurfacing the patella is performed the majority of the time in the US and in many regions it is considered standard practice. In many countries, however, the patella is left unresurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine whether more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced
Graft choices for revision anterior cruciate ligament (ACL) reconstruction and complex ligament reconstructions of the knee are controversial. The aim of our study was to analyze the biomechanical effect of harvesting bone plugs from both the distal and proximal poles of the patella, to simulate a simultaneous harvesting of a Bone – Patellar Tendon – Bone and Quadriceps Tendon – Bone grafts, in a transverse stress environment. Sixty Bovine
Rotational mal-alignment of the patella-femoral interface will result in increased wear. Highly cross-linked polyethylene will decrease wear even if mal-aligned. A biomechanical model based on high load and flexion was used to measure wear of rotationally aligned and mal-aligned all-polyethylene
The purpose of this study was to characterise accurately, the extent and geometry, and produce representative rigid resin models of full thickness articular cartilage lesions of various types, shapes and sizes on the articular surface of pig
Introduction. Management of the patellofemoral surface in total knee arthroplasty (TKA) remains a topic of debate. Incidence of anterior knee pain and incidence of repeat operation have been the focus of several recent meta-analyses, however there is little recent data regarding patients” subjective ability to kneel effectively after TKA. The purpose of this study was to compare patient reported outcomes, including reported ability to kneel, after total knee arthroplasty with and without patellar resurfacing. Methods. Retrospective chart review of 84 consecutive patients who underwent primary TKA with patella resurfacing (56 knees) or without patella resurfacing (28 knees) having a minimum of 2.5 year follow up was performed. Oxford knee scores (OKS), visual analog pain scores (VAS), and questionnaires regarding ability to kneel were evaluated from both groups. Inability to kneel was defined as patients reporting inability or extreme difficulty with kneeling. Shapiro-Wilk test was used to determine normality of data. Mann Whitney U test was used to compare the OKS and VAS between groups. Chi square test was used to compare kneeling ability between groups. Statistical analysis was performed with SPSS version 23 (IBM, Aramonk, NY). Results. The 84 patients included 26 males and 58 females with average age 66.5 (range 46–91). Average follow up was 51 months (range 30–85). There was no significant difference in the percentage of female patients (64% vs 79%), age (67.8 vs 63.8), or reoperation rate (4% vs 7%) between the resurfaced and non-resurfaced groups. There was significantly longer follow up in the non-resurfaced group (57 vs 48 months). There was no statistically significant difference between the resurfacing and non-resurfacing group in terms of OKS (39 vs 38) or VAS (2.5 vs 3.0). However, those patients who did not have their patellofemoral joint resurfaced were more likely to report ability to kneel when compared to the resurfacing group (64% vs 39%, p=0.035). Kneeling ability was not correlated with duration of follow up, patient age or VAS. Kneeling ability was higher in female patients (57%) than males (27%), p=0.017. Discussion. There is concern for increased anterior knee pain and reoperation in patients whose
Previosuly, Komistek et al. have shown that the kinematics of the patellofemoral joint is altered after a TKA surgery. Specifically the implanted patella experiences significantly less rotation than the natural patella. Also, in early flexion, the patellofemoral contact positions differed significantly between implanted and non-implanted
The aim of this study was to assess the outcome of patients who underwent ElmslieTrillat antero-medial tibial tubercle transfer for treatment of persistent symptomatic anterior knee pain due to chondromalacia
The October 2012 Knee Roundup. 360. looks at: autologous chondrocytes and chondromalacia
Whereas thermography has already been used as an assessment of disease activity in some kinds of inflammatory arthritis, it is a new method for objektive pain evaluation in patients with joint prosthesis. To our knowledge, no study has tested the correlation between increase of temperature and anterior knee pain with total knee prosthesis yet. Thirteen patients were included in this study who suffered from anterior knee pain of the retinaculum
Introduction. Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. Materials and Methods. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant (Journey II Bi-Cruciate Stabilized Knee System, Smith & Nephew, Inc., Memphis) were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Results. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m. 2. ; 67.1% obese;
Purpose: Patellar bracing is a common, mechanical-based treatment strategy for patellofemoral osteoarthritis (OA). It is thought that the brace corrects patellar tracking, however, this correction has not been quantified in the OA population. Through advances in magnetic resonance imaging (MRI), we can now assess patellar tracking in three-dimensions. Method: We assessed three-dimensional patellar tracking in ten subjects with symptomatic radiographic patellofemoral knee OA using a validated, quasi-static, MRI-based method. Four conditions were studied:. no knee brace, no load,. no knee brace, 15% bodyweight (BW) load,. knee brace, no load,. knee brace, 15% BW load. Patellar tracking (flexion, spin and tilt; proximal, lateral and anterior translation) was assessed. Comparisons were made at 1° increments over the coincidental range of knee flexion between the no-brace and brace conditions, at no load and 15% BW load, using a paired t-test with Bonferroni correction. Results: All subjects (7 female, 3 male, 60.9±1.3 yrs, 89.5±19.3 kg) had radiographic lateral patellofemoral OA and seven had concomitant tibiofemoral OA (KL grade≥2). Under no load, the brace extended (mean=2.7°, CI=[2.4°, 2.9°], P<
0.001) and medially tilted (mean=−1.4°, CI=[−1.6°, −1.2°], P<
0.001) the
Introduction A biomechanical model was developed to measure wear of all-polyethylene patellar components as it relates to femoral component mal-rotation. The model, based on high load and flexion activities such as stair climbing, was used to differentiate the effects of femoral mal-rotation and differing materials on a single patellar design. Methods The patellar components (Scorpio®, Stryker-Howmedica-Osteonics) were cemented onto metal fixtures and articulated against “aligned” and “mal-aligned” (six degrees internally rotated) femoral components. The patellar components were subjected to a constant force and articulated against femoral components flexing from 600 to 1200.
Purpose of the study: The stability of the patella over the femur depends on several factors, one being the rotatory freedom of the tibia. Femorotibial rotatory laxity of a total knee arthroplasty (TKA) can be:. dictated by the congruence of the polyethylene in an ultracongruent plateau;. completely free, depending solely on the ligament structures in a self-aligning prosthesis;. the consequence of a compromise between the two, using a semi-constrained prosthesis. With the OMNIA system, the unique femoral piece can be combined with a Wallaby ultracongruent plateau (WUC), a self-aligning mobile plateau (SAL), or a semiconstrained plateau with preservation of the posterior cruciate ligament (Wallaby 1, W1). A comparative study of these three prostheses was performed to evaluate the influence of femorotibial rotatory constraint on patellar stability. Material and methods: The series included 157 TKA: 68 SAL,44 WUC and 45 W1. The same surgeon operated all patients in three successive series. The operative technique was the same using the same instrument set. The femoral piece was inserted first with an automatic rotation systematically set at 5° with the posterior condyles. The knees were varus (71%), valgus (20%) and perfectly aligned (9%). A patellar prosthesis was used in only 10.8% due to excessive wear as assessed intraoperatively. A medial approach was used for the varus knees and a lateral approach for the valgus knees greater than 10°, independently of preoperative patellar stability. Radiological outcome was assessed on the 30° femoro-patellar views.
Introduction: Mobile bearing TKRs may allow some axial rotation and also compensate for a slight tibiofemoral rotational mismatch. This is thought to provide better kinematics and a more natural patellar movement. This theoretical advantage has not been verified in clinical studies for the tibiofemoral kinematics. However, little is known about the patellofemoral kinematics of mobile bearing TKRs. The aim was to compare patellar kinematics among the anatomic knee, fixed bearing TKR and mobile bearing TKR. Methods: Optical computer navigation marker arrays (Brainlab) were attached to the femur, tibia and patella of 9 whole lower extremities (5 fresh cadavers). The trial components of a fixed bearing posterior stabilised TKR (FB) (Sigma PFC, Depuy) were implanted using a tibia first technique. Then the tibia component was changed to a posterior stabilised mobile bearing tibia component (MB) (Sigma RP Stabilised). The
A series of 100 consecutive osteoarthritic patients was randomised to undergo total knee replacement using a Miller-Galante II prosthesis, with or without a cemented polyethylene patellar component. Knee function was evaluated using the American Knee Society score, Western Ontario and McMaster University Osteoarthritis index, specific patellofemoral-related questions and radiographic evaluation until the fourth post-operative year, then via questionnaire until ten years post-operatively. A ten-point difference in the American Knee Society score between the two groups was considered a significant change in knee performance, with α and β levels of 0.05. The mean age of the patients in the resurfaced group was 71 years (53 to 88) and in the non-resurfaced group was 73 years (54 to 86). After ten years 22 patients had died, seven were suffering from dementia, three declined further participation and ten were lost to follow-up. Two patients in the non-resurfaced group subsequently had their
The Insall-Salvati method of determining the position of the patella by radiography was employed in fifty-one patients with chondromalacia
To measure the patellar height the ratio of the articular length of the patella to the height of the lower pole of the articular cartilage above the tibial plateau is measured on a lateral radiography of the knee, flexed beyond 30 degrees. Normal values lie between 0-54 and 1-06. The subluxing patella is at the upper end of the normal range, but, in chondromalacia, the male
Orthopaedic surgeons vary in their attitude towards resurfacing of the patella in total knee arthroplasty. Few studies are available to assess outcome and patient preference. We evaluated post-operative anterior knee pain and knee preference in patients with bilateral knee replacements and unilateral patellar resurfacing. We reviewed 30 patients who had undergone bilateral knee replacement with patellar resurfacing on only one side. Follow-up was from five to 12 years and the patients were assessed using the Knee Society rating, an anterior knee pain rating and a satisfaction score. Patients were also asked specifically if they had a preference for either knee. Assessment was performed without knowing which patella had been resurfaced. Fourteen patients (47%) favoured the resurfaced knee, six (20%) the un-resurfaced knee and 10 (33%) had no particular preference. The overall prevalence of anterior knee pain was 50% in the un-resurfaced cases (six mild, six moderate, three severe) and 20% in the resurfaced knees (four mild, two moderate). No significant difference was found between knee scores. Three un-resurfaced
We describe a lumbar facet syndrome in which disabling symptoms are associated with normal or near-normal plain radiographs. Local spinal fusion relieved symptoms in 12 patients; the excised facet joint surfaces showed some of the histological changes seen in chondromalacia
Introduction and Aims: Many authors believe that patellar resurfacing decreases the incidence of anterior knee pain. We analysed the result of 150 of our own patients. Method: Over the past four years we performed 150 total knee arthroplasties. None of the
During total knee replacement (TKR), surgeons can choose whether or not to resurface the patella, with advantages and disadvantages of each approach. Recently, the National Institute for Health and Care Excellence (NICE) recommended always resurfacing the patella, rather than never doing so. NICE found insufficient evidence on selective resurfacing (surgeon’s decision based on intraoperative findings and symptoms) to make recommendations. If effective, selective resurfacing could result in optimal individualized patient care. This protocol describes a randomized controlled trial to evaluate the clinical and cost-effectiveness of primary TKR with always patellar resurfacing compared to selective patellar resurfacing. The PAtellar Resurfacing Trial (PART) is a patient- and assessor-blinded multicentre, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary TKR for primary osteoarthritis at NHS hospitals in England, with an embedded internal pilot phase (ISRCTN 33276681). Participants will be randomly allocated intraoperatively on a 1:1 basis (stratified by centre and implant type (cruciate-retaining vs cruciate-sacrificing)) to always resurface or selectively resurface the patella, once the surgeon has confirmed sufficient patellar thickness for resurfacing and that constrained implants are not required. The primary analysis will compare the Oxford Knee Score (OKS) one year after surgery. Secondary outcomes include patient-reported outcome measures at three months, six months, and one year (Knee injury and Osteoarthritis Outcome Score, OKS, EuroQol five-dimension five-level questionnaire, patient satisfaction, postoperative complications, need for further surgery, resource use, and costs). Cost-effectiveness will be measured for the lifetime of the patient. Overall, 530 patients will be recruited to obtain 90% power to detect a four-point difference in OKS between the groups one year after surgery, assuming up to 40% resurfacing in the selective group.Aims
Methods
The purpose of this study was to evaluate a high flex porous tantalum metal monoblock component system implanted through a MIS technique. A fellowship trained surgeon proficient in MIS surgery performed 109 consecutive TKAs in 95 patients. Patients were implanted with a tantalum monoblock tibia and a fiber-metal cruciate-retaining high flex femur through a MIS midvastus approach. Ninety uncemented porous tantulum monoblock
Introduction. Mobile-bearing TKRs allow some axial rotation and may provide a more natural patellar movement. The aim was to compare patellar kinematics among the normal knee, fixed-bearing and mobile-bearing TKR. Methods. Optical computer navigation (Brainlab) was used to track the position of the femur, tibia and patella in 9 whole lower extremities (5 fresh cadavers) in the natural knee, in the same knee with the trial components of a posterior stabilised fixed-bearing TKR (FB) (Sigma PFC, Depuy) and a posterior stabilised mobile-bearing TKR (MB) (Sigma RP Stabilised). The
The management of failed autologous chondrocyte
implantation (ACI) and matrix-assisted autologous chondrocyte implantation
(MACI) for the treatment of symptomatic osteochondral defects in
the knee represents a major challenge. Patients are young, active
and usually unsuitable for prosthetic replacement. This study reports
the results in patients who underwent revision cartilage transplantation
of their original ACI/MACI graft for clinical or graft-related failure.
We assessed 22 patients (12 men and 10 women) with a mean age of
37.4 years (18 to 48) at a mean of 5.4 years (1.3 to 10.9). The
mean period between primary and revision grafting was 46.1 months
(7 to 89). The mean defect size was 446.6 mm. 2. (150 to
875) and they were located on 11 medial and two lateral femoral condyles,
eight
Since its introduction in Christchurch in 1989, the mobile bearing LCS prosthesis has been used in over 3 500 total knee arthroplasty (TKA) procedures. The prosthesis is unique in that it has a mobile articulation not only at the tibiofemoral joint but also at the patellofemoral joint. The tibiofemoral articulation may be posterior cruciate retaining (meniscal bearings - MB) or sacrificing (rotating platform - RP). Clinical and radiological assessment of 569 patients over three to nine years shows no significant difference between MB and RP groups with respect to Knee Society and New Jersey knees or the WOMAC functional score. In 93% of patients results were good or excellent. There were more early complications among MB patients, with five MB dislocations. However, four of these dislocations occurred in the early years this prosthesis and may reflect surgical inexperience. Clinical evidence of posterior cruciate laxity was present in 15% of the MB group, but there was no significant difference between knee scores of this group, the rest of the MB group, or the RP group. When resurfaced
A consecutive series of 235 total knee arthroplasties using the PFC system was followed prospectively for at least ten years in 186 patients. The operation was for osteoarthritis in 150 knees, for rheumatoid arthritis in 83, and for Paget’s disease and femoral osteonecrosis in one knee each. At the latest review 56 patients had died, fi ve were too ill to assess and three could not be traced. The PFC knee replacement utilised was a nonconforming posterior-cruciate-retaining prosthesis with a polyethylene insert which is fl at in the sagittal plane. The patella was resurfaced using a metal-backed component in 170 cases, but later in the series we used an all-polyethylene component in 22 knees; 43
To stabilise the dislocating patella, one can increase the medial vectors, decrease the lateral vectors, or combine these options. Oblique strengthening of vastus medialis increases the medial vectors. This muscle is an active secondary constraint for stabilising the patella. Strengthening this muscle is the cornerstone of treatment of patellar instability, but it is often unsuccessful if the medial patello-femoral ligament is deficient. The medial patellofemoral ligament is the primary passive constraint to lateral dislocation of the patella. Reconstruction of this ligament, which tenses in extension, stabilises the patella in most cases, without the danger of secondary late-stage patellofemoral degeneration. However, in high-riding
Although complications associated with patello-femoral (PF) joint account for up to 50% of total knee replacement (TKR) revision procedures (Lee), the PF joint has been overlooked in wear simulations. The goal of this study was to develop an in vitro model to simulate patella wear in TKR’s. This report describes the concepts of an in vitro model for normal gait and the preliminary results of experimental validation. The primary consideration in the development of the current model was modeling of the in vivo kinetics and kinematics. Since the in vivo kinetics are not well documented, the current model adapted a PF joint force pattern of gait measured one year postoperatively in a telemetric distal femoral replacement (Taylor et al). The maximum force was increased from 571N to 1780N (2.5xBody Weight) to compensate for muscle deficiency and to better reflect a maximum load representative of the in vivo situation. In vivo kinematics were adopted from measurements of Lafortune. Only the PF flexion was included in the model as a simplification of the complex patella motions. The phase relationship between the kinematic and kinetic waveforms was adjusted to replicate the in vivo situation. A 6-station knee simulator carried out the experimental validation with a test frequency of 1.5Hz. The test was intended to run for 5 million cycles, with CMM wear measurements (Muratoglu et al.) taken every million cycles. The preliminary measurements showed wear patterns in the tested
Introduction. Patella femoral joint bearings in total knee replacements have shown low wear (3.1 mm. 3. /MC) under standard gait simulator conditions. 1. However, the wear in retrieval studies have shown large variations between 1.3 to 45.2 mm. 3. /year. 2. Previous in vitro studies on the tibial femoral joint have shown wear is dependent on design, materials and kinematics. 3. . The aim of this study was to investigate the influence of the design (geometry) and shape on the wear rate of patella femoral joints in total knee replacements. Materials and Methods. The Leeds/Prosim knee simulator was used to investigate the wear of two types of commercially available
Most common complication of non-navigated classic total knee arthroplasty (TKA) relates to patella. Not resurfacing the patella makes exposure more difficult in a mini-approach which may add to its potential complications. Effect of navigated mini sub-vastus TKA on native patella is clinically and radiologically studied, observing also, whether severity of deformity or obesity adds to
Introduction. We have been re-evaluating patellofemoral alignment after total knee arthroplasty (TKA) by using a weight- bearing axial radiographic view after detecting patellar maltracking (lateral tilt > 5° or lateral subluxation > 5 mm) on standard non-weight-bearing axial radiographs. However, it is unclear whether the patellar component shape affects this evaluation method. Therefore, we compared 2 differently shaped components on weight-bearing axial radiographs. Methods. From 2004 to 2013, 408 TKAs were performed with the same type of posterior-stabilized total knee implant at our hospital. All
Clinical Problem: fractures under tension are common injuries and occur when patients are falling on partial flexed limbs under maximal contraction of the extensor muscles. Typical injuries are patella and olecranon. For these fractures the tension belt osteosyntheses is the mainly used procedure. A high complication rate regarding dislocation, bone healing, pain and functional outcome are reported. This is due to the unstable fixation with the tension belt because of the tendon insertion around the bone fragment witch allow secondary loosening of the tension belt under alternating load. This was found allready 1987 by Brill and Hopf in an experimental study. Materials and Methods: To improve stabilisation a new device was developed: the XS (4,5mm diameter) and the XXS nail (3,5mm) witch is locked with threaded wires and a set screw allows fracture compression inside the nail independend from the soft tissues around. Fiber Wire cerclage transversal around the threaded wire ends allow the fixation of additional frontal plane fragments or marginal fragments. Experimental test were performed in a patella sow-bone models and showed superior to tension bel (patella) and Plate fixation/fibula). On the other side the locked nail system allows percutaaneous osteosynthesis of the whole ulna also in shaft, distal fractures and shortening osteotomies. All clinical cases treated with the XS/XXS nail where recorded prospectively and re-examined after 6–12 months. From may 2000 to march 2002 76 patients with olecranon fractures were evaluated. 85% of the olecranon fracture patients could be re-examined. Most patients where treated immediately or after wound healing without splint. Results: the experimental results shows in all XS nail group no gap after alternating load of 250 and 500N and a rigidity a little higher than that of the not osteotomised
INTRODUCTION. Wear and fracture of patellar components has been frequently reported as a failure mode for cemented and press-fit patellar components. Malalignment of the patellar components may cause higher contact stresses, which may lead to excessive wear, delamination, and/or component fracture. In vitro testing of the patella in a clinically relevant malaligned condition is necessary to demonstrate adequate performance of the patellar component and assess the endurance of its fixation features under severe loading conditions. The purpose of this study was to test in vitro the patellar components under malaligned conditions using a knee joint simulator. MATERIALS AND METHODS. A 6 station MTS (Eden Prairie, MN) knee joint wear simulator and Alpha Calf Fraction serum (Hyclone Labs, Logan, UT) diluted to 50% with a pH-balanced 20-mMole solution of deionized water and EDTA was used (protein level = 20 g/l) for testing. Asymmetric, all-polyethylene, patellar components with an overall construct thickness of 11 mm (Duracon®, Stryker Orthopaedics, Mahwah, NJ) were used. Appropriately sized cobalt-chrome femoral components articulated against the
During knee arthroplasty operations, it appeared that different patterns of patellar degeneration occur. To confirm this, 123
Aims: The most common complications after total knee arthroplasty (TKA) are the result of patellar complications. The causes of patellar problems range from sub-luxation, dislocation, component loosening, rupture of the patellar tendon, excess wear of the polyethylene (especially after metal backing), retropatellar pain, and patellar fracture. The incidence of these patellar complications after TKA ranges from 5–30%. Selective retention of the patella has been recommended more recently although there are still potential problems of maltracking and anterior knee pain. According to the nationwide registration of all TKAs in Finland since 1980 it seems evident that interest of patellar retention during the primary operation has now been stabilized at the level of about 55 per cent. At the same time there are, however, quite a high incidence of reoperations done due to patellar complications or later resurfacing of the patella in connection of revisions done with other indications. Methos:. Database of the Finnish Arthroplasty Register was evaluated from the years 1999 and 2000 focusing on the reoperations done either due to patellar complication (in the notiþcation: indication for revision) or due to other reason (to be speciþed in full text). These were further divided into three main categories: removal or fracture of
Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs. Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m2 (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years.Aims
Methods
The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR. A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs.Aims
Methods
While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA. A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations.Aims
Methods
We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all
For the management of displaced patellar fractures, surgical fixation using cannulated screws along with anterior tension band wiring is getting popular. Clinical and biomechanical studies have reported that using cannulated screws and a wire instead of the modified tension band with Kirschner wires improves the stability of fractured
It is a not so uncommon clinical scenario: well-fixed, well-aligned, balanced total knee arthroplasty with continued pain. However, radiographs also demonstrate an unresurfaced patella. The debate continues and the controversy remains as whether or not to routinely resurface the patella in total knee arthroplasty. In perhaps the most widely referenced article on the topic, the overall revision rates were no different between the resurfaced (9%) and the unresurfaced (12%) groups and thus their conclusion was that similar results can be obtained with and without resurfacing. However, a deeper look in to the data in this study shows that 4 times more knees in the unresurfaced group were revised for patellofemoral problems. A more recent study concluded that selectively not resurfacing the patella provided similar results when compared to routinely resurfacing. The study does emphasise however, that this conclusion depends greatly on femoral component design and operative diagnoses. This suggests that selective resurfacing with a so-called “patella friendly” femoral component in cases of tibio-femoral osteoarthritis, is a safe and effective strategy. Finally, registry data would support routine resurfacing with a 2.3 times higher relative risk of revision seen in the unresurfaced TKA. Regardless of which side of the debate one lies, the not so uncommon clinical scenario remains; what do we do with the painful TKA with an unresurfaced patella. Precise and accurate diagnosis of the etiology of a painful TKA can be very difficult, and there is likely a strong bias towards early revision with secondary patellar resurfacing in the painful TKA with an unresurfaced TKA. At first glance, secondary resurfacing is associated with relatively poor outcomes. Correia, et al. reported that only half the patients underwent revision TKA with secondary resurfacing had resolution of their complaints. Similarly, only 53% of patients in another series were satisfied with the procedure and pain relief. The conclusions that can be drawn from these studies and others are that either routine patellar resurfacing should be performed in all TKA or, perhaps more importantly, we need to better understand the etiology of pain in an otherwise well-aligned, well-balanced, well-fixed TKA. It is this author's contingency that the presence of an unresurfaced patella leads surgeons to reoperate earlier, without truly identifying the etiology of pain or dissatisfaction. This strong bias; basically there is something more that can be done, therefore we should do it, is the same bias that leads to early revision of partial knee arthroplasty. While very difficult, we as knee surgeons should not revise a partial knee or secondarily resurface a patella due to pain or dissatisfaction. Doing so, unfortunately, only works about half the time. The diagnostic algorithm for evaluating the painful, uresurfaced TKA includes routinely ruling out infection with serum markers and an aspiration. Pre-arthroplasty radiographs should be obtained to confirm suitability and severity of disease for an arthroplasty. An intra-articular diagnostic injection with Marcaine +/− corticosteroid should provide significant pain relief. MARS MRI may be beneficial to evaluate edema within the patella. Lastly, operative implant stickers to confirm implant manufacturer and type are critical as some implants perform less favorably with unresurfaced
Insufficient treatment response in rheumatoid arthritis (RA) patients requires novel treatment strategies to halt disease progression. The potential benefit of combination of cytokine-inhibitors in RA is still unclear and needs further investigation. To explore the impact of combined deficiency of two major cytokines, namely interleukin (IL)-1 and IL-6, in this study double deficient mice for IL-1αβ and IL-6 were investigated in different tumour necrosis factor (TNF)-driven inflammatory bone disorders, namely peripheral arthritis and sacroiliitis, as well as systemic bone loss. Disease course, histopathological features of arthritis, and micro-CT (µCT) bone analysis of local and systemic bone loss were assessed in 15-week-old Aims
Methods
Introduction. Presentation of our outcome in implant survival and clinical function using rotating-hinge knee prosthesis in revision total knee arthroplasty. Method. A retrospective review of 44 revision TKA containing 21 RHK (Biomet) and 23 MRH (Stryker). The patient population consisted of 27 women and 17 men with an average age of 75 years at the time of the revision. The mean follow-up period was 13 months. The clinical and functional results were evaluated according to the Knee-Society-Score (KSS) after 3, 6, 12, 24 and 36 months together with a x-ray. Results. The indication for the revision included aseptic loosening and ligamentous instability, 6 times as primary total knee replacement, an infected total knee in 6 cases and fractures with severe bone defect in 4 cases. The KSS pain improved from 49 (range 23–70) to 76 (range 34–98). The KSS function did not show any significant improvement of 60 (range 10–55) to 65 (range 20–100). The ROM improved with 53% from 74 (range 50–110) to 113 (range 65–130). Our complications have been revisions of hematoma in 4 cases, an infection/recurrence of infection in 2 cases with following explantation. There were 3 ligamentum
Introduction. Patellar resurfacing is performed in more than 90% of primary total knee arthroplasties (TKAs) in the United States, yet far fewer
BACKGROUND. Patella resurfacing in TKA remains controversial. The purpose of this study was to compare the long-term clinical outcome in TKA in patients undergoing bilateral TKAs with one patella resurfaced and the other patella nonresurfaced. METHODS. Twenty-nine patients (58 knees) underwent primary bilateral TKA for osteoarthritis. These patients were enrolled in a prospective randomised double blinded study and represent a subset of a larger study of patella resurfacing. All patients received the same posterior cruciate sparing TKA. Patients each had one knee randomised to treatment with or without patella resurfacing. The contralateral knee then received the alternative patellar treatment, such that all patients had one knee with a resurfaced patella and the other nonresurfaced. Clinical evaluations consisted of routine radiographic and clinical follow-up and included with a Knee Society Score patellofemoral specific patient questionnaire. Twenty-eight patients (56 knees) participated and were followed for a mean of 118 months (range, 69–146 months). RESULTS. There were no significant differences between the knees treated with and without patellar resurfacing with regard to range of motion, KSCRS, or the pain and function scores. Forty-six percent (13/28 patients) of patients preferred the resurfaced knee, 36% (10/28) the nonresurfaced knee, and 18% (5/28) had no preference. Two patients (7%) in the nonresurfaced group required revision for a patellofemoral related complication, compared to one patient (3.5%) in the group with a resurfaced patella. CONCLUSIONS. Ten year follow-up reveals equivalent results for resurfaced and nonresurfaced
The lateral centre-edge angle (LCEA) is a plain radiological measure of superolateral cover of the femoral head. This study aims to establish the correlation between 2D radiological and 3D CT measurements of acetabular morphology, and to describe the relationship between LCEA and femoral head cover (FHC). This retrospective study included 353 periacetabular osteotomies (PAOs) performed between January 2014 and December 2017. Overall, 97 hips in 75 patients had 3D analysis by Clinical Graphics, giving measurements for LCEA, acetabular index (AI), and FHC. Roentgenographical LCEA, AI, posterior wall index (PWI), and anterior wall index (AWI) were measured from supine AP pelvis radiographs. The correlation between CT and roentgenographical measurements was calculated. Sequential multiple linear regression was performed to determine the relationship between roentgenographical measurements and CT FHC.Aims
Methods
The aim of this study was to determine the association between knee alignment and the vertical orientation of the femoral neck in relation to the floor. This could be clinically important because changes of femoral neck orientation might alter chondral joint contact zones and joint reaction forces, potentially inducing problems like pain in pre-existing chondral degeneration. Further, the femoral neck orientation influences the ischiofemoral space and a small ischiofemoral distance can lead to impingement. We hypothesized that a valgus knee alignment is associated with a more vertical orientation of the femoral neck in standing position, compared to a varus knee. We further hypothesized that realignment surgery around the knee alters the vertical orientation of the femoral neck. Long-leg standing radiographs of patients undergoing realignment surgery around the knee were used. The hip-knee-ankle angle (HKA) and the vertical orientation of the femoral neck in relation to the floor were measured, prior to surgery and after osteotomy-site-union. Linear regression was performed to determine the influence of knee alignment on the vertical orientation of the femoral neck.Aims
Methods
Introduction. The success of knee replacement surgery depends, in part, on restoration of the correct alignment of the leg with respect to the load-bearing vector passing from the hip to the ankle (the mechanical axis). Conventional thinking is that the correct angle of resection of the distal femur (Valgus Cut Angle, VCA) depends on femoral length or femoral offset, though femoral bowing, in addition to length and medial offset, may also have a significant influence on the VCA. We hypothesized that femoral bowing has a strong effect on the VCA necessary to restore physiologic alignment after arthroplasty or osteotomy. Methods. A total of 102 long-leg radiographs were obtained from patients scheduled for primary total knee arthroplasty. The patients on average were 41% male 59% female, 67.9 ± 11.1 years, 67.0 ± 4.7 in, 192 ± 43 lbs, and had a BMI of 29.7 ± 4.8. All radiographs were prepared with the feet placed in identical rotation and the
Purpose of Study:. Various techniques have been described and are still used for treating recurrent dislocation of the patella when conservative measures fail. Among them are distal, proximal and combined realignment techniques and lateral releases. Since being shown proof of the biomechanical importance of the medial patellofemoral ligament (MPFL) in patellofemoral instability, the reconstruction of the MPFL has gained in popularity. The objective of this paper is to present a case series with preliminary clinical results using the gracilis tendon to reconstruct the MPFL. Method:. Between 01/07 and 03/11 23 knees in 21 patients underwent reconstruction of the MPFL.4 of these patients had had previous surgery. Preoperatively the Caton Deschamps ratio using plain x-rays was worked out and the TT/TG distance was measured using CT scanning. Using these measurements as a guideline, 7 cases underwent a tibial tubercle transfer as an additional procedure. In 6 of the cases an additional cartilage procedure was required. The technique was simplified using intra-operative x-rays to achieve anatomical tunnel placement. Results:. The Tegner Activity Score was used to evaluate the patients preoperatively and at a minimum of 6 months postoperatively. The scores improved on average from 3,6 to 7,4. One patient had an extensor lag of 10 degrees at 3 months. This had normalised by 6 months. One patient had recurrence of her instability and required a revision MPFL reconstruction using an allograft. One patient had recurrent episodes of patella subluxation but no overt dislocation. Conclusion:. This case series gave good functional results using the Tegner Activity score. The procedure of MPFL reconstruction was effective in stabilising the
Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths. All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total leg length, femoral and tibial length, articulotrochanteric distance (ATD), and subtrochanteric femoral length were compared between PD side and the unaffected side. Furthermore, we compared leg length measurements between patients who did and who did not have a contralateral epiphysiodesis.Aims
Methods
We have performed intra-osseous venography on 22 patients with chondromalacia
Introduction. MERA Quest Knee System (Quest Knee) is a posterior cruciate ligament–retaining prosthesis considering the anatomical features and lifestyles of the Japanese. As for the anatomical features, we reduced the size of prosthesis and set a smaller interval of sizes because Japanese knees are smaller and flatter than those of Caucasians. As for the lifestyles, we evaluated in vivo patellar tracking during deep knee flexion and the condylar geometry in the axial plane of magnetic resonance imaging. It was found that the patella sank deeply into the intercondylar notch and that the articular surface of the lateral condyle began to curve steeply. We adopted this shape and engraved the lateral condyle deep to reduce the pressure of the patellofemoral joint and to get better range of motion (ROM). For the contact pressure rise in the femorotibial joint by engraving the lateral condyle, the insert was suited to the shape of the femoral component. Furthermore, we increased the thickness of the posterior flange of the femoral component and changed the posterior radius of curvature gradually, and this shape allowed the flexion of 155°. We have used Quest Knee for clinical applications from October 2009. We studied the short-term results of Quest Knee. Methods. Between June 2010 and July 2013, the same senior surgeon performed 59 consecutive primary operations with Quest Knee. Forty patients (44 knees) were women, and 14 patients (15 knees) were men. The mean patient age was 72.5 years (range, 59–89 years). All were osteoarthritis knees. Coronal deformity was varus in 58 knees and valgus in one knee. All operations were performed with a measured resection technique, and all
We describe a syndrome combining abnormalities of the pelvis, knee and foot in three related patients with a familial history of small dislocated
The results of resurfacing or not resurfacing the articular cartilage of the patella were reviewed in 71 knees--47 with rheumatoid arthritis and 24 with osteoarthritis--which had been replaced with the ICLH prosthesis. Two rheumatoid and osteoporotic
Twelve closely related members of one family were found to have small or absent
Purpose. To establish the reliability of reporting and recording revision hip and knee arthroplasties by comparing data in the National Joint Registry (NJR), Hospital Episode Statistics (HES) and our local theatre records. Methods. The paper theatre registers for all orthopaedic theatres in the Royal Derby Hospitals NHS Trust were examined for details of revision hip and knee replacements carried out in 2007 and 2008. This was then cross-checked and merged with the local electronic theatre data to obtain a definitive local record of all revision hip and knee arthroplasties. Data for the same period was requested from the NJR and HES and these data were checked against our definitive local record for discrepancies. The HES codes used were the same codes used to compile the recent NJR annual reports. Results. The theatre registers and ORMIS identified 271 revision hip and knee arthroplasties in the study period. The NJR had corresponding data for 176 (65%) of these, and HES had 250 (92%). 10 cases (4%) were not recorded by either NJR or HES: 8 secondary resurfacings of
Two men, aged 21 and 50 years, were seen with ossification of the patellar tendon after injury to the knee in adolescence. They complained of pain and had patella alta. Large bony masses were excised from below the affected
Anterior knee pain after total knee arthroplasty (TKA) occurs in 5% to 30% of patients whether or not the patella has been resurfaced. We retrospectively reviewed our patients, none of whom underwent patellar resurfacing. Only 2% had anterior knee pain, none requiring revision surgery. Our follow-up was between two and five years. We paid particular attention to removing osteophytes and conducting a thorough peripatellar synovectomy and a circumpatellar cautery denervation. Our results compare favourably to those in the literature, whether or not the
Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended.Aims
Methods
1. Eight patients are described in whom the
Summary. Macroscopic grading, histologic grading, morphometry, mineral analysis, and mechanical testing were performed to better understand the changes that occur in the cartilage, calcified cartilage, and subchondral bone in early osteoarthritis. Introduction. The earliest changes in osteoarthritis (OA) remain poorly understood due to the difficulty in detecting OA before patients feel pain. We have published details of the mature bovine patella model showing the pre-OA state where no gross macroscopic changes are visible yet microstructural changes indicate very early degeneration. In this new study, we proceed to investigate this model further by more comprehensively quantifying the changes in articular cartilage (AC), zone of calcified cartilage (ZCC), and subchondral bone (SB) in pre and early OA. Methods.
Background. Autologous chondrocyte implantation (ACI) and mosaicplasty (MP) are two methods of repair of symptomatic articular cartilage defects in the adult knee. This study represents the only long-term comparative clinical trial of the two methods. Methods. A prospective, randomised comparison of the two modalities involving 100 patients with symptomatic articular cartilage lesions was undertaken. Patients were followed for ten years. Pain and function were assessed using the modified Cincinnati score, Bentley Stanmore Functional rating system and visual analogue scores. ‘Failure’ was determined by pain, a poor outcome score and arthroscopic evidence of graft disintegration. Results. Patients had a mean age at index operation of 31. There was a long mean pre-op duration of symptoms of seven years and the defects had an average of 1.5 operations (excluding arthroscopy) to the articular cartilage lesion prior to the cartilage repair surgery. The aetiology of the articular cartilage defects was mainly trauma; some patients had osteochondritis dissecans or chondromalacia