Advertisement for orthosearch.org.uk
Results 1 - 100 of 1029
Results per page:

Aims. The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V. Methods. This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children. Results. Test-retest reliability for the overall mCCHQ score was good (intraclass correlation coefficient 0.78), and no dimension demonstrated poor reliability. The surgical intervention cohort comprised ten children who had preoperative and postoperative mCCHQ scores at a minimum of six months postoperatively. The mCCHQ tool demonstrated a significant improvement in overall score from preoperative assessment to six-month postoperative follow-up assessment (p < 0.001). Conclusion. The mCCHQ demonstrated responsiveness to intervention and good test-retest reliability. The mCCHQ is proposed as an outcome tool for use within a national surveillance programme for children with CP. Cite this article: Bone Jt Open 2023;4(8):580–583


Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims. In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. Methods. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival. Results. A total of 114 operations were performed on 112 patients with a mean age of 80.2 years (SD 8.9). The 30-day and one-year mortality were 1% (n = 1) and 13% (n = 15), respectively. Median follow-up was 6.6 years (interquartile range 6.0 to 7.3). Kaplan-Meier estimates showed a survivorship of 95% at one year and 90% at five years (95% confidence interval 84% to 95%) for cannulated screws. Nine patients underwent further hip surgery: four revision to total hip arthroplasty, one revision to hemiarthroplasty, three removals of screws, and one haematoma washout. Posterior tilt was assessable in 106 patients; subsequent surgery was required in two of the six patients identified with a posterior angle > 20° (p = 0.035 vs angle < 20°). Of the 100 patients with angle < 20°, five-year survivorship was 91%, with seven patients requiring further surgery. Conclusion. This study of cannulated hip screw fixation for undisplaced fractures in patients aged ≥ 60 years reveals a construct survivorship without further operation of 90% at five years. Cannulated screws can be considered a safe reliable treatment option for Garden I and II fractures. Caution should be taken if posterior tilt angle on lateral view exceeds 20°, due to a higher failure rate and reoperation, and considered for similar management to Garden III and IV injuries. Cite this article: Bone Jt Open 2022;3(3):182–188


Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims. This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. Methods. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm. 3. ). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. Results. CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm. 2. . Conclusion. Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 46 - 46
2 May 2024
Palmer A Fernquest S Logishetty K Rombach I Harin A Mansour R Dijkstra P Andrade T Dutton S Glyn-Jones S
Full Access

The primary treatment goal for patients with femoroacetabular impingement syndrome, a common hip condition in athletes, is to improve pain and function. In selected patients, in the short term following intervention, arthroscopic hip surgery is superior to a pragmatic NHS- type physiotherapy programme. Here, we report the three-year follow-up results from the FemoroAcetabular Impingement Trial (FAIT), comparing arthroscopic hip surgery with physiotherapy in the management of patients with femoroacetabular impingement (FAI) syndrome. Two-group parallel, assessor-blinded, pragmatic randomised controlled study across seven NHS England sites. 222 participants aged 18 to 60 years with FAI syndrome confirmed clinically and radiologically were randomised (1:1) to receive arthroscopic hip surgery (n = 112) or physiotherapy and activity modification (n = 110). We previously reported on the hip outcome score at eight months. The primary outcome measure of this study was minimum Joint Space Width (mJSW) on Anteroposterior Radiograph at 38 months post randomisation. Secondary outcome measures included the Hip Outcome Score and Scoring Hip Osteoarthritis with MRI (SHOMRI) score. Minimum Joint Space Width data were available for 101 participants (45%) at 38 months post randomisation. Hip outcome score and MRI data were available for 77% and 62% of participants respectively. mJSW was higher in the arthroscopy group (mean (SD) 3.34mm (1.01)) compared to the physiotherapy group (2.99mm (1.33)) at 38 months, p=0.017, however this did not exceed the minimally clinically important difference of 0.48mm. SHOMRI score was significantly lower in the arthroscopy group (mean (SD) 9.22 (11.43)) compared to the physiotherapy group (22.76 (15.26)), p-value <0.001. Hip outcome score was higher in the arthroscopy group (mean (SD) 84.2 (17.4)) compared with the physiotherapy group (74.2 (21.9)), p-value < 0.001). Patients with FAI syndrome treated surgically may experience slowing of osteoarthritisprogression and superior pain and function compared with patients treated non- operatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 86 - 86
23 Jun 2023
Marin-Peña O
Full Access

Young patients undergoing THA or hip used. HOS and iHOT33 have demonstrated to be useful in hip preservation surgery but never used in THA. The aim of the study was to evaluate long-term clinical outcomes with HOS and iHOT33 in hip arthroscopy and THA. We conducted a retrospective study with prospective data collection of 118 consecutive young patients (<65 y.o.) between 2008 to 2012 who underwent hip arthroscopy or THA. The mean follow-up was 12.05 years. All surgeries were done by the same senior surgeon. PROMs used were iHOT-33 and HOS preoperatively, at one year and 10 years. SPSS Statistics Grad Pack 28.0 software was used for statistical analysis. Arthroscopy Group (57 patients): Mean age 35.36 years. 55.93% were male. iHOT33 mean differential improvement was 24.43 at 1 year, 70,17% exceed MCID and 49,1% SCB. HOS mean differential improvement was 16.26 at one year. 54,38 % patients exceed MCID and 49,36% SCB. At 10 years, iHOT33 mean differential improvement was 14,36 and 12.56 for HOS. Regarding complications, 3 patients underwent THA (5.26%) and 10 (17.54%) continued with groin pain. THA Group (61 patients): Mean age 52,54 years. 55.73% were male. Cementless THA was used in all patients with ceramic on ceramic used in 77%. iHOT33 mean differential improvement was 41,57 at 1 year. 95,08% patients exceed MCID and 85,25% SCB. HOS mean differential improvement was 16.57 points at one year. 85,25% patients exceed MCID and 81,97% SCB. At 10 years, iHOT33 mean differential improvement was 20,15 and 14.12 for HOS. Regarding complications, 1 patient underwent DAIR for infection (1.64%) and 1 dislocation with close reduction (1.64%). iHOT33 or HOS scores should be considered to be used in young active patients after hip preserving surgery or THA, with more predictable results at long-term in THA group


Bone & Joint Research
Vol. 10, Issue 9 | Pages 594 - 601
24 Sep 2021
Karunaseelan KJ Dandridge O Muirhead-Allwood SK van Arkel RJ Jeffers JRT

Aims. In the native hip, the hip capsular ligaments tighten at the limits of range of hip motion and may provide a passive stabilizing force to protect the hip against edge loading. In this study we quantified the stabilizing force vectors generated by capsular ligaments at extreme range of motion (ROM), and examined their ability to prevent edge loading. Methods. Torque-rotation curves were obtained from nine cadaveric hips to define the rotational restraint contributions of the capsular ligaments in 36 positions. A ligament model was developed to determine the line-of-action and effective moment arms of the medial/lateral iliofemoral, ischiofemoral, and pubofemoral ligaments in all positions. The functioning ligament forces and stiffness were determined at 5 Nm rotational restraint. In each position, the contribution of engaged capsular ligaments to the joint reaction force was used to evaluate the net force vector generated by the capsule. Results. The medial and lateral arms of the iliofemoral ligament generated the highest inbound force vector in positions combining extension and adduction providing anterior stability. The ischiofemoral ligament generated the highest inbound force in flexion with adduction and internal rotation (FADIR), reducing the risk of posterior dislocation. In this position the hip joint reaction force moved 0.8° inbound per Nm of internal capsular restraint, preventing edge loading. Conclusion. The capsular ligaments contribute to keep the joint force vector inbound from the edge of the acetabulum at extreme ROM. Preservation and appropriate tensioning of these structures following any type of hip surgery may be crucial to minimizing complications related to joint instability. Cite this article: Bone Joint Res 2021;10(9):594–601


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 100 - 100
1 May 2019
Maloney W
Full Access

The challenges faced by hip surgeons have changed over the last decade. Historically, fixation, polyethylene wear, osteolysis, loosening and failure to osseointegrate dominated the discussions at hip surgery meetings. With the introduction of highly crosslinked polyethylene, wear and osteolysis are currently not significant issues. Improved surgical technique has resulted in a high rate of osseointegration and once fixed, loosening of cementless components is rare. In this session, we will focus on issues that orthopaedic surgeons performing hip surgery routinely face including bearing couples in the young active patient, implant choices in the dysplastic hip and osteoporotic femur, evaluation and management of the unstable hip and differential diagnosis of the painful THR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 59 - 59
10 Feb 2023
Hancock D Morley D Wyatt M Roberts P Zhang J van Dalen J
Full Access

When removing femoral cement in revision hip surgery, creating an anterior femoral cortical window is an attractive alternative to extended trochanteric osteotomy. We describe our experience and evolution of this technique, the clinical and radiological results, and functional outcomes. Between 2006 and 2021 we used this technique in 22 consecutive cases at Whanganui Hospital, New Zealand. The average age at surgery was 74 years (Range 44 to 89 years). 16 cases were for aseptic loosening: six cases for infection. The technique has evolved to be more precise and since 2019 the combination of CT imaging and 3-D printing technology has allowed patient-specific (PSI) jigs to be created (6 cases). This technique now facilitates cement removal by potentiating exposure through an optimally sized anterior femoral window. Bone incorporation of the cortical window and functional outcomes were assessed in 22 cases, using computer tomography and Oxford scores respectively at six months post revision surgery. Of the septic cases, five went onto successful stage two procedures, the other to a Girdlestone procedure. On average, 80% bony incorporation of the cortical window occurred (range 40 −100%). The average Oxford hip score was 37 (range 22 – 48). Functional outcome (Oxford Hip) scores were available in 11 cases (9 pre-PSI jig and 2 using PSI jig). There were two cases with femoral component subsidence (1 using the PSI jig). This case series has shown the effectiveness of removing a distal femoral cement mantle using an anterior femoral cortical window, now optimized by using a patient specific jig with subsequent reliable bony integration, and functional outcomes comparable with the mean score for revision hip procedures reported in the New Zealand Joint Registry


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 297 - 301
1 Mar 2012
Haddad FS Konan S

An international faculty of orthopaedic surgeons presented their work on the current challenges in hip surgery at the London Hip Meeting which was attended by over 400 delegates. The topics covered included femoroacetabular impingement, thromboembolic phenomena associated with hip surgery, bearing surfaces (including metal-on-metal articulations), outcomes of hip replacement surgery and revision hip replacement. We present a concise report of the current opinions on hip surgery from this meeting with appropriate references to the current literature


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 36 - 36
23 Jun 2023
Bizot P
Full Access

Genetic skeletal disorders constitute a rare and heterogeneous bone diseases often leading to poor quality of life. Several surgical options are available. The surgeon must deal with specific features (bone deformity, previous procedures, abnormal bone quality, stiffness or instability, muscle weakness). The questions concern the feasibility of the procedures and the surgical strategy.

55 patients (26 W, 29 M) were reviewed between 2016 and 2022. The mean age of the patients was 35 years (17–71). The diagnosis included 9 hereditary multiple exostoses, 8 osteogenesis imperfecta, 6 multiple epiphyseal dysplasia congenita, 6 achondroplasia, 4 osteopetrosis, 3 pycnodysostosis, 3 hypophosphatemic rickets, 3 fibrous dysplasia, 2 mucopolysaccharidosis, and 10 miscellaneous. 25 patients were referred for hip problems (40 hips). 4 patients (7 hips) requiring a THA have not been operated (4 planned). 4 patients (6 hips) had a proximal femoral fixation (2 osteotomies, 4 fracture fixations). 17 patients (27 hips) sustained a THA (25 primary, 2 revisions). All of them were operated by one operator, using a posterolateral approach and standard implants (including 7 dysplastic and 2 short stems). No customized implant has been used.

As regard the 27 THAs, the mean follow up was 4.2 years (1–12). The early complications included 2 femoral cracks and 1 femur fracture. There were 2 revisions (1 cup loosening at 2 years, 1 stem loosening at 4 years). No infection nor dislocation occurred. All the patients were satisfied with their treatment and regain some autonomy. 3 THA were considered as unfeasible.

Constitutional bone diseases need a multidisciplinary program of care. The indication for surgery is based on a mutual trust patient/surgeon, a careful evaluation of benefits/risks, and an accurate imaging to anticipate the difficulties. The expected results are a better function and quality of life, and a stability over time.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 35 - 35
23 Jun 2023
Lavernia C Patron LP Lavernia CJ Gibian J Hong T Bendich I Cook SD
Full Access

Fracture of contemporary femoral stems is a rare occurrence. Earlier THR stems failed due to design issues or post manufacturing heat treatments that weakened the core metal. Our group identified and analyzed 4 contemporary fractured femoral stems after revision surgery in which electrochemical welds contributed to the failure.

All four stems were proximally porous coated titanium alloy components. All failures occurred in the neck region post revision surgery in an acetabular cup exchange. All were men and obese. The fractures occurred at an average of 3.6 years post THR redo (range, 1.0–6.5 years) and 8.3 years post index surgery (range, 5.5–12.0 years). To demonstrate the effect of electrocautery on retained femoral stems following revision surgery, we applied intermittent electrosurgical currents at three intensities (30, 60, 90 watts) to the polished neck surface of a titanium alloy stem under dry conditions.

At all power settings, visible discoloration and damage to the polished neck surface was observed. The localized patterns and altered metal surface features exhibited were like the electrosurgically-induced damage priorly reported.

The neck regions of all components studied displayed extensive mechanical and/or electrocautery damage in the area of fracture initiation. The use of mechanical instruments and electrocautery was documented to remove tissues in all 4 cases.

The combination of mechanical and electrocautery damage to the femoral neck and stem served as an initiation point and stress riser for subsequent fractures. The electrocautery and mechanical damage across the fracture site observed occurred iatrogenically during revision surgery. The notch effect, particularly in titanium alloys, due to mechanical and/or electrocautery damage, further reduced the fatigue strength at the fractured femoral necks. While electrocautery and mechanical dissection is often required during revision THA, these failures highlight the need for caution during this step of the procedure in cases where the femoral stem is retained.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1149 - 1158
1 Nov 2023
Chen B Zhang JH Duckworth AD Clement ND

Aims

Hip fractures are a major cause of morbidity and mortality, and malnutrition is a crucial determinant of these outcomes. This meta-analysis aims to determine whether oral nutritional supplementation (ONS) improves postoperative outcomes in older patients with a hip fracture.

Methods

A systematic literature search was conducted in August 2022. ONS was defined as high protein-based diet strategies containing (or not containing) carbohydrates, fat, vitamins, and minerals. Randomized trials documenting ONS in older patients with hip fracture (aged ≥ 50 years) were included. Two reviewers evaluated study eligibility, conducted data extraction, and assessed study quality.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 1 - 2
1 Mar 2024
Haddad FS Berry DJ


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 765 - 766
1 Jul 2022
Haddad FS Malchau H


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 91 - 91
1 Aug 2017
Maloney W
Full Access

The challenges faced by hip surgeons have changed over the last decade. Historically, fixation, polyethylene wear, osteolysis, loosening and failure to osseointegrate dominated the discussions at hip surgery meetings. With the introduction of highly crosslinked polyethylene, wear and osteolysis are currently not significant issues. Improved surgical technique has resulted in a high rate of osseointegration and once fixed, loosening of cementless components is rare. In this section, we will focus on issues that orthopaedic surgeons performing hip surgery routinely face including bearing couples in the young active patient, implant choices in the dysplastic hip and osteoporotic femur, evaluation and management of the unstable hip and differential diagnosis of the painful THR


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_9 | Pages 13 - 13
1 Aug 2015
Norman-Taylor F
Full Access

The disadvantages of hip spica casts following hip surgery for cerebral palsy include fractures, plaster sores, soiling and general inconvenience. In this series, 56 hips in 31 children aged 4 to 16 years (mean 8) were treated for hip displacement in keeping with the recommendations of others (eg Miller et al 1997) between 2005 and 2008 by one consultant. There were 29 open reductions for a Reimer's migration index (RMI) greater than 50%. A blade plate was used for the femoral osteotomy, and an acetabuloplasty was performed for 22 hips. No casting or immobilisation of any sort was used. The average length of stay was 5 days. The results at 5 the year follow-up were chosen so that all patients were at the same stage. The average RMI pre-operatively for displaced hips was 76.9 +/− 21.3. At follow-up it was 18.8 +/− 19.7. 18 patients had pain prior to hip surgery; 6 had pain during follow-up, and 4 of these responded to removal of metal; and one required a proximal femoral resection. There were 3 complications: one re-dislocation in the immediate post-operative period, one mal-union because the blade plate cut out; and one of the three walking children fractured below the blade plate 2 ½ months after surgery. There were no infections. The radiographic and clinical outcomes of hip reconstruction without hip spica immobilisation are good, reproducible and long-lasting. The child may be nursed free post-operatively and discharged in his or her own chair. As a result of studying these patients, since 2009 we have introduced locking plates for better fixation, and pre- and post-operative Paediatric Pain Profiles and CPCHILD questionnaires


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 613 - 613
1 Oct 2010
Stevens M Bulstra S Hoekstra T Van Den Akker-Scheek I Wagenmakers R
Full Access

Objective of the study is to determine to what extent patients experience more limitations 1–5 years after revision total hip arthroplasty (THA) compared to patients after primary THA, and if this is accompanied by a reduction in physical activity behavior. Five hundred and six patients were included: 372 primary and 134 revision THA. Questionnaires were used to measure limitations and physical activity. Linear regression analysis showed that patients after revision surgery report significantly more, clinically relevant limitations compared with primary THA patients, but did not show a significant difference in mean total minutes of physical activity per week. Physical activity behavior appeared to be similar for primary and revision THA patients. The results stress the importance of determining different aspects of recovery after THA.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2006
Astore F Spotorno L Dagnino A Fiorentini C Ricci D Ursino N Scardino M
Full Access

The aim of this study is to evaluate which patients, if any, can be eligible for a rapid discharge from Hip Surgery Department at 24 hours after primary total hip arthroplasty. Methods In this retrospective clinical trial were included all patients undergone to primary total hip arthroplasty in our Hip Surgery Department from January to June 2004. Exclusion criteria were preoperative anaemia (Hb< 12g/dL), coagulation disease, hip fracture, previous hip surgery and not-weight bearing indication after operation. All patients received an uncemented total hip arthroplasty with posterior surgical approach in regional anaesthesia. All patients had the same post-operative (PO) management including analgesia, prevention of DVT, immediate muscle exercises and physiotherapy for walking on crutches starting on the second PO day. The clinical history, vital parameters, haemoglobin (Hb) value before surgery and for 5 days PO, adverse events like luxation and transfusion were registered. For the statistical evaluation were used the paired “t-test” with a level of significance set at 95%. Differences and p values of < 0.05 were considered significant. Results 234 patients (mean age 65y; range 21–91y) were admitted to the study. 128 women and 106 men. For the blood loss evaluation, the presence of no homogeneous preoperative Hb lead us to analyse the decrease rate of preoperative Hb (DRPH). The mean DRPH was: 22,47% at 1dayPO; 25,09% at 2 daysPO; 22,83% at 3 daysPO; 26,76% at 5 daysPO. For the safety evaluation were considered the incidence of transfusions (limit was set at Hb< 8g/dL) that were related to the preoperative Hb and the age. The transfusion incidence for each preoperative Hb (PrHb) value was: 14% (7/49) for 12< PrHb< 13; 11% (6/53) for 13< PrHb< 14; 11% (5/43) for 14< PrHb< 15; 7% (2/26) for 15< PrHb< 16g/dL. For age under 70y and PrHb> 14g/dL there were the lowest transfusion incidence: 3% (2/41). No adverse events were able to prevent patients from going to Rehabilitation Unit. All patients were able to do their own physiotherapical programme. Pain during physiotherapy was low (mean value of VAS = 3,47). Discussion During the last decade the improvement of anaesthesiologic and surgical technique with minimally invasive soft tissue approach (small incision and little muscular sacrifice) lead to a significant reduction in adverse events after primary total hip arthroplasty. So the relative safety of this surgery justifies the growing importance of intensive rehabilitation and fast recovery. This study shows the safety of a rapid discharge from the Hip Surgery Department. The main adverse event after 24 hours PO is the necessity of blood transfusions, but the incidence rate of only 3%, like in patients with preoperative Hb> 14g/dL and age below 70 years, is not a problem for the physicians of the Rehabilitation Unit. Conclusion This study confirms the possibility to perform a safe One Day Hip Surgery by an accurate selection of the patient


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 179 - 184
1 Feb 2012
Sutter M Hersche O Leunig M Guggi T Dvorak J Eggspuehler A

Peripheral nerve injury is an uncommon but serious complication of hip surgery that can adversely affect the outcome. Several studies have described the use of electromyography and intra-operative sensory evoked potentials for early warning of nerve injury. We assessed the results of multimodal intra-operative monitoring during complex hip surgery. We retrospectively analysed data collected between 2001 and 2010 from 69 patients who underwent complex hip surgery by a single surgeon using multimodal intra-operative monitoring from a total pool of 7894 patients who underwent hip surgery during this period. In 24 (35%) procedures the surgeon was alerted to a possible lesion to the sciatic and/or femoral nerve. Alerts were observed most frequently during peri-acetabular osteotomy. The surgeon adapted his approach based on interpretation of the neurophysiological changes. From 69 monitored surgical procedures, there was only one true positive case of post-operative nerve injury. There were no false positives or false negatives, and the remaining 68 cases were all true negative. The sensitivity for predicting post-operative nerve injury was 100% and the specificity 100%. We conclude that it is possible and appropriate to use this method during complex hip surgery and it is effective for alerting the surgeon to the possibility of nerve injury


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1055 - 1060
1 Aug 2005
Trikha SP Singh S Raynham OW Lewis JC Mitchell PA Edge AJ

We describe the clinical and radiological results of 120 consecutive revision hip replacements in 107 patients, using the JRI Furlong hydroxyapatite-ceramic-coated femoral component. The mean age of the patients at operation was 71 years (36 to 92) and the mean length of follow-up 8.0 years (5.0 to 12.4). We included patients on whom previous revision hip surgery had taken place. The patients were independently reviewed and scored using the Harris hip score, the Western Ontario and McMaster Universities osteoarthritis index (WOMAC) and the Charnley modification of the Merle d’Aubigné and Postel score. Radiographs were assessed by three reviewers for the formation of new bone, osteolysis, osseointegration and radiolucent lines in each Gruen zone. The mean Harris hip score was 85.8 (42 to 100) at the latest post-operative review. The mean WOMAC and Merle d’Aubigné and Postel scores were 34.5 and 14.8, respectively. The mean visual analogue score for pain (possible range 0 to 10) was 1.2 overall, but 0.5 specifically for mid-thigh pain. There were no revisions of the femoral component for aseptic loosening. There were four re-revisions, three for infection and one for recurrent dislocation. Radiological review of all the femoral components, including the four re-revisions showed stable bony ingrowth and no new radiolucent lines in any zone. Using revision or impending revision for aseptic loosening as an end-point, the cumulative survival of the femoral component at ten years was 100% (95% confidence interval 94 to 100). We present excellent medium- to long-term clinical, radiological and survivorship results with the fully hydroxyapatite-ceramic-coated femoral component in revision hip surgery


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 72 - 72
1 Jan 2004
Mundy GM Esler CNA Harper WM
Full Access

Introduction: With an ever-increasing elderly population the rise in primary total hip replacement is inevitable. This translates into a comparative rise in revision hip surgery. We performed an observational study to determine current revision hip surgical practices in one UK region. Methods: We utilized a regional hip register (Trent Arthroplasty Audit Group (TAAG)) to review current revision hip surgical practice in our region. 136 surgeons in 21 different hospitals, covering a population of 6.2 million, contribute to the register. We analysed completed data forms to produce the following results. Results: 875 revision THRs performed between 2000 and 2002 were identified. 54% were female, with a mean age of 70 (range 26–97). 45 different femoral stems requiring revision were identified. Reasons for revision were aseptic loosening of both components (23%), cup alone (24%), stem alone (17%), infection (14%), recurrent dislocation (10%), periprosthetic fracture (5%) and acetabular erosion (3%). Over 25 different femoral stems and over 30 different acetabular components were utilised by surgeons. In 70% of cases the femoral and acetabular components were made by different manufacturers. Bone graft was used in approximately 50% of cases. 90% of centres contributing to TAAG perform revision hip surgery. 24% of all revision THRs were performed by surgeons performing 5 or less per year. Only 40% of revision THRs were performed by ‘revision surgeons’ performing > 20 per year. Conclusions: It is evident the majority of centres, both teaching and DGH, in our region regularly perform revision hip surgery, with up to a quarter performed by non-revision specialists. With increasing numbers of prostheses available, high numbers of component mismatch use, and the inevitable increase in future need for revision hip surgery, is the occasional revision surgeon compromising patient care? Will this have future medico-legal consequences?


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 228 - 228
1 Mar 2004
Konduru SR Khaweri F Finlayson D
Full Access

Introduction: Revision hip surgery with impaction allografting is an attractive operation because of its potential to restore lost bone stock. Several authors have reported variable results, some disastrous, with massive subsidence of the stem. Aim: To study the radiographic and clinical results of impaction allografting for revision hip surgery done in our department. Materials and methods: 49 patients (50 hips) underwent revision hip surgery using the impaction allografting technique and the Exeter stem between the years 1993 to 1997. The average follow up was 6 years (range 4 – 9 years). Results: There were 7 dislocations. One patient had early painful subsidence of the stem requiring revision. 44 (90%) hips had subsidence of stem equal to or less than 5 mm at last follow up. 5 (10%) had subsidence ranging from 6 to 7 mm. Hip function was uniformly good and patients were extremely satisfied. Conclusion: Revision hip surgery with impaction allografting is an effective operation. With meticulous attention to this technique, revision hip surgery need not necessarily be associated with inferior outcomes compared to primary hip surgery


Bone & Joint Open
Vol. 4, Issue 8 | Pages 559 - 566
1 Aug 2023
Hillier DI Petrie MJ Harrison TP Salih S Gordon A Buckley SC Kerry RM Hamer A

Aims

The burden of revision total hip arthroplasty (rTHA) continues to grow. The surgery is complex and associated with significant costs. Regional rTHA networks have been proposed to improve outcomes and to reduce re-revisions, and therefore costs. The aim of this study was to accurately quantify the cost and reimbursement for a rTHA service, and to assess the financial impact of case complexity at a tertiary referral centre within the NHS.

Methods

A retrospective analysis of all revision hip procedures was performed at this centre over two consecutive financial years (2018 to 2020). Cases were classified according to the Revision Hip Complexity Classification (RHCC) and whether they were infected or non-infected. Patients with an American Society of Anesthesiologists (ASA) grade ≥ III or BMI ≥ 40 kg/m2 are considered “high risk” by the RHCC. Costs were calculated using the Patient Level Information and Costing System (PLICS), and remuneration based on Healthcare Resource Groups (HRG) data. The primary outcome was the financial difference between tariff and cost per patient episode.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 173 - 173
1 Mar 2008
Hauptfleisch J McLardy-Smith P
Full Access

Significant proximal femoral bone deficiency in revision hip surgery poses a considerable challenge, especially as revision hip surgery is increasing in prevalence. Many femoral prosthetic devices, which compensate for this bone loss, are available to surgeons but ideally one wants to restore viable proximal bone stock. The Oxford Universal Hip (OUH) has been designed and modified with these challenges in mind. This is atrimodular, non-locking device that allows for some rotation and subsidence in the cement. Load transfer occurs at the proximal wedge, thus avoiding proximal stress shielding. The OUH has been used extensively in both primary and revision hip surgery and is particularly useful when used in conjunction with proximal impaction bone grafting. The main aim of this study was to determine the clinical outcome of the patients. The viability and survivorship of the impacted bone graft was assessed in order to give some indication of adequate perfusion of the incorporated bone grafting. Between 1999 and 2002 the OUH, in combination with proximal impaction bone grafting, was implanted in 72 hip revisions in 69 patients. All patients were clinically evaluated using the Oxford Hip score. Histological samples of impacted bone grafting were analysed by a pathologist 2 years after implantation to assess viability and perfusion of the impacted bone graft. The Oxford Hip Score improved from a pre-operative to a post-operative score of 45 (26–58) to 24.3 (12–43) respectively (p< 0.001). The mean follow up time was 32.7 months and in that time there were no re-revisions for aseptic loosening. Histology demonstrated viable bone stock in the proximal femur where bone grafting had been impacted 2 years previously. The OUH is a versatile hip prosthesis for use in revision hip arthroplasty and is especially well suited to proximal impaction bone grafting where it is possible to restore viable bone stock


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 18 - 18
1 Jun 2017
Wilson S Unsworth R Ajwani S Sochart D
Full Access

Litigation costs are significant and increasing annually within the National Health Service (NHS) in England. The aim of this work was to evaluate the burden of successful litigation relating to hip surgery in England. Secondary measures looked at identifying the commonest causes of successful legal action. A retrospective review was conducted on the National Health Service Litigation Authority (NHSLA) database. All successful claims related to hip surgery over a 10 year period from 2003–2013 were identified. A total of 798 claims were retrieved and analysed. The total cost of successful claims to the NHS was £66.3 million. This compromised £59 million in damages and £7.3 million in NHS defence-related legal costs. The mean damages for settling a claim were £74,026 (range £197-£1.6million). The commonest cause of claim was post-operative pain with average damages paid in relation to this injury being £99,543. Nerve damage and intra-operative fractures were the next commonest cause of claim with average damages settled at £103,465. Legal action in relation to hip surgery is a considerable source of cost to the NHS. The complexity of resolving these cases is reflected in the associated legal costs which represent a significant proportion of payouts. With improved understanding of factors instigating successful legal proceedings, physicians can recognise areas where practice and training need to be improved and steps can be taken to minimise complications leading to claims


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 25 - 25
1 Nov 2017
Reddy G Stritch P Manning M Gudena R Emms N
Full Access

Background. Revision total hip arthroplasty is a technically demanding procedure and especially removing a well fixed femoral stem is a challenge for revision surgeons. There are various types of trochanteric osteotomies used during revision surgery; extended trochanteric osteotomy (ETO) is being more popular. Aim. The aim of this study is to look at types of trochanteric osteotomy used during the revision surgery. We looked at the success and failure of these osteotomies. Failure of the osteotomy is defined by complete pull off by the hip abductors resulting in osteotomy fragment is no contact with the femur. We sought to assess the time to healing of osteotomy and number of cables used. Methods. We retrospectively reviewed the hospital theatre database and identified 97 patients who underwent revision hip surgery from June 2008 to December 2015. Among these 35 patients (36% of patients) had trochanteric osteotomy for either extraction of femoral stem or removal of cemented mantle. Results. Most common cause of revision was aseptic loosening in 22 cases (62%) followed by peri prosthetic fracture 6 cases (17%), 1. st. stage of revision surgery in infective cause in 4 cases (11%). Depending on the length of the osteotomy performed we divided the patients into two groups. The first group had osteotomy just around the greater trochanter, which is called short trochanteric osteotomy group and the second group had extended trochanteric osteotomy where the osteotomy length is at least of 15cms and preserving the vastus lateralis attachment to the osteotomy. 7 patients had short trochanteric osteotomy and remaining 28 patients had extended trochanteric osteotomy. In the short trochanteric osteotomy group had 4 out of 6 patients had failure of the osteotomy repair. In extended trochanteric osteotomy group, there was one immediate failure and another one had delayed trochanteric pull off out of 28 patients (93% success rate). The time taken for the osteotomy to heal in short trochanteric osteotomy group was 8 months where as in the extended osteotomy group it was 5 months. The mean number of cables used was 3 in both groups. There was no subsidence seen during the post op follow up in either group. Conclusion. Our study concluded that ETO is a safe procedure with a low complication rate rather than short trochanteric osteotomy. Implications. Awareness about the biomechanics of ETO and its indications can make ETO an important tool in the revision surgeon's armamentarium


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 402 - 402
1 Sep 2009
Buchanan JM
Full Access

Introduction: Revision hip surgery is likely to become more frequent with the continued use of cemented primary hip prostheses. Primitive stem cells from bone marrow become osteocytes in the presence of hydroxyapatite ceramic (HAC). Consequently there is osseointegration of an HAC surface in bleeding cancellous bone/marrow. However, damaged bone in the revision situation does not provide the necessary stem cells for osseointegration. Revision surgery using standard length (150mm) HA coated stems is not always satisfactory. Using a 200 mm stem will extend the operating field into fresh, undamaged cancellous bone and marrow. Method: Since 1988 more than 2600 HAC hips have been implanted for primary and revision hip cases. This includes 148 revisions. The continued use of primary HAC hips has reduced the necessity for revision hip surgery. There is a dwindling population of cemented, loosening hips requiring revision. Patients are assessed radiologically and using the Harris Hip Score (HHS) pre. and post-operatively on an annual basis. Results: Since 1991 the longer 200mm stems have been used in 73 cases. The results have been rewarding. The system works with improved HHS. Defects from debris disease fill in and stems are seen to bond to the host bone particularly at the tip. There have been no prosthetic fractures. Only one case has needed re-revision when a stem remained un-bonded in the presence of a transverse femoral fracture. Two other stems are probably not bonded. This represents 4% failure. Discussion: HA bonding is a successful system of fixation in primary hip arthroplasty. Using a 200mm stem in revision cases allows virgin bone marrow to provide the necessary stem cells for fixation. These longer HA coated stems should be used in revision surgery


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 103 - 103
1 Mar 2009
Astore F Spotorno L Traverso F Dagnino A Ricci D Ursino N Scardino M
Full Access

The aim of this study is to evaluate techniques which may reduce intra and Post-Operative (PO) bleeding in hip surgery. Methods: In this prospective study, from 9/2005 to 6/2006, we evaluated Blood Loss (BL) after primary total hip arthroplasty. Exclusion criteria were anti-coagulant drugs not discontinued 10 days before surgery and patients whose condition precluded weight bearing PO. We included total hip arthroplasty with posterior surgical approach, spinal anaesthesia, hypotensive surgery and peri-operative blood salvage (Ortho PAS, Euroset). When appropriate, the Mini-Invasive Approach (MIA) was used. In a different sub-set of patients, including some of the minimally invasive patients, a new bipolar Radio-Frequency sealer (TissueLink) was used. The PO program had pain control, LMWH for prevention of DVT, exercise from the day of surgery and walking on crutches from the next day. We analysed: blood loss after surgery and for 3 days; haemoglobin values (g/dL) before surgery and for 5 days PO; thigh circumference pre-op and at 5 days and adverse events such as transfusions and luxation. For the statistical evaluation the paired “t-test” was used, with a level of significance set at 95%. Differences and p values of < 0.05 were considered significant. Results: 324 patients (mean age 68; range 23 to 89; 179 F & 145 M) were admitted to the study. Mean BL was 305ml intraoperative, 501ml at 6 hours PO, 304ml at 1day PO, 132ml at 2 days PO and trace at 3 days. Rather than simple unit measures, we analyzed the Percent Change in Hb from preoperative levels (%CHb). The patients had a mean %CHb of 23,09% at 1day PO, 26,67% at 2 days PO, 28,13% at 3 days and 29,07% at 5 days. Transfusion rates (TR; trigger set at Hb< 8g/dL) were related to the preoperative Hb and age. Overall TR was 15% (51/324), the prevalence of homologous transfusion was 7% (24/324). The TR for each Hb value: 21% (15/69) for Hb=12–13, 20% (20/98) for Hb=13–14, 17% (15/88) for Hb=14–15 and 5% (1/29) for Hb=15–16. The mean value of pain during rehabilitation was 3,11(VAS). MIA (53/324) was associated with reduced BL (mean %CHb at 1st day PO 19.12; TR 9%), but with high variability. The use of bipolar sealer (58/324) was associated with a significant reduction in overall BL (mean %CHb at 1st day PO 15.83; TR 5%) as well as a reduction of thigh swelling (37%) and of mean rehabilitation pain (30%; VAS=2.15). Discussion: Reduced blood loss, reduced post-operative pain and a faster functional resumption are obtained with both the minimally invasive approach and the TissueLink sealer approach. In addition, MIA provides muscle preservation and the use of the TissueLink sealer provides reduced post-operative swelling. Conclusion: This study shows that both the minimally invasive surgical approach and the use of an irrigated RF bipolar sealer can lead to reduced blood loss and faster functional resumption following hip surgery


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 162 - 162
1 Mar 2008
PATTYN C De Smet K
Full Access

Postoperative dislocations are known to be a big problem in revision surgery. In literature dislocation rates vary from 4.8% to 33% after previous surgery. In revision surgery, impingement of the implant components, the capsular and soft tissue release, muscular weakness and greater trochanter problems can give additional instability. The reason for revision is important, where instability, infection and tumour cases will lead to a higher percentage of dislocations. The use of big metal heads on polyethylene should be avoided because of the higher volumetric wear. With the new developments of metal-on-metal hip resurfacing and the production of big modular metal heads, the metal-on-metal bearing should guarantee a low-wear result without osteolysis. Between November 2000 and December 2003 45 patients requiring a revision were treated with a Birmingham Hip Resurfacing cup (MMT, UK) and a big metal-on-metal modular head. All surgery was done with a posterolateral approach. Cup sizes range from 44 to 66 mm, head sizes range from 38 to 58 mm. The head sizes most often used were 58 mm, 54 mm and 50 mm. All patients were prospective followed using the Orthowave software (CRDA France). In this series of 45 revisions (mean age 56.17) with large modular heads we encountered 2 dislocations, which give us a dislocation rate of 4.4%. One of these dislocations became recurrent and was revised to a full-constrained acetabular component. Our own dislocation rate in revision hip surgery is 13% (21/159) in the anterolateral approach. Dislocations using the posterolateral approach increased this percentage to 14.8% (21/141). Taking in account that 31% of the causes of revision were infection and recurrent dislocation, this trial demonstrates that large diameter ball heads give beside a better range of movement also a statistically proven reduction in the dislocation rate in revision hip surgery


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 36 - 36
1 Aug 2013
Herd J Joseph J McGarvey M Tsimbouri P Bennett A Meek R Morrison A
Full Access

Allogenic blood is a finite resource, with associated risks. Previous studies have shown intra-operative cell salvage (ICS) can reduce allogenic transfusion rates in orthopaedic surgery. However, recent concerns regarding the efficacy and cost-effectiveness of ICS mean we must continually re-assess its usefulness in current practice. This study was carried out to review the use of ICS, to establish if its use has led to a reduction in patient exposure to post-op allogenic transfusion. All orthopaedic patients who underwent ICS and re-infusion between 2008–2010 in the Southern General Hospital (SGH) were audited. The Haemoglobin (Hb) drop, volume of blood re-infused and post-op allogenic transfusion rates were recorded. The revision hip group was compared to a similar SGH cohort, who underwent surgery by the same surgeons between 2006–2008, and a pre-2005 control group. The Cell Saver (Haemonetics) machine was used. The proportion of patients who received a post-op allogenic transfusion fell by 55% in the 2008–2010 ICS cohort compared with the control, and by 40% compared with the previous ICS study group. In both instances, this was accompanied by a statistically significant (p<0.001) reduction in mean number of units transfused per patient. ICS has been shown to be effective in reducing rates and volume of post-op allogenic transfusion in patients undergoing revision hip surgery at the SGH. ICS has been used with increasing efficiency over time


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 181 - 181
1 Mar 2006
Bridgens J Evans C Dobson P Hamer A
Full Access

Background: Perioperative red cell salvage may be of use in cases where significant blood loss is likely. The purpose of this investigation was to see if its use in revision hip surgery led to a reduction in homologous blood transfusion requirement. Methods: 48 patients were identified who had undergone revision hip surgery with the use of a Cell Saver device for perioperative autologous transfusion. Patients were individually matched to control patients who had undergone revision hip surgery without the Cell Saver. Patients were matched for age, sex and eight operative variables, which were chosen to indicate the type of revision surgery and possible level of blood loss, to ensure that the groups were comparable. Total homologous transfusion requirement in both groups was recorded as well as pre and post-operative haemoglobin levels. Results: The groups were well matched for age, sex and operative variables. The total homologous transfusion requirement was significantly lower in the Cell Saver group than the control group (mean 2.6 v 6.4 units of packed cells respectively, p 0.0006). There was no difference in pre-operative haemoglobin between the groups but it was lower in the Cell Saver group post-operatively (Cell Saver 10.1g/dl v Control 10.6g/dl, p 0.06). There was no difference in length of operation. Conclusions: Use of perioperative red cell salvage was associated with significantly lower homologous transfusion requirement. This is the first study looking at the use of perioperative red cell salvage in revision hip surgery with matching of patients on the basis of operative variables. A cost analysis shows that use of the Cell Saver has significant financial advantage in these patients


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 43 - 43
1 Mar 2005
Bridgens J Evans C Hamer A
Full Access

Background: Perioperative red cell salvage may be of use in cases where significant blood loss is likely. The purpose of this investigation was to see if its use in revision hip surgery led to a reduction in homologous blood transfusion requirement. Methods: 48 patients were identified who had undergone revision hip surgery with the use of a Cell Saver device for perioperative autologous transfusion. Patients were individually matched to control patients who had undergone revision hip surgery without the Cell Saver. Patients were matched for age, sex and eight operative variables ,which were chosen to indicate the type of revision surgery and possible level of blood loss, to ensure that the groups were comparable. Total homologous transfusion requirement in both groups was recorded as well as pre and post-operative haemoglobin levels. Results: The groups were well matched for age, sex and operative variables. The total homologous transfusion requirement was significantly lower in the Cell Saver group than the control group (mean 2.6 v 6.4 units of packed cells respectively, p 0.0006). There was no difference in pre-operative haemoglobin between the groups but it was lower in the Cell Saver group post-operatively (Cell Saver 10.1g/dl v Control 10.6g/dl, p 0.06). There was no difference in length of operation. Conclusions: Use of perioperative red cell salvage was associated with significantly lower homologous transfusion requirement. This is the first study looking at the use of perioperative red cell salvage in revision hip surgery with matching of patients on the basis of operative variables. A cost analysis shows that use of the Cell Saver has significant financial advantage in these patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 173 - 173
1 Sep 2012
Rogers B Garbedian S Kuchinad R MacDonald M Backstein D Safir O Gross A
Full Access

Introduction. Revision hip arthroplasty with massive proximal femoral bone loss remains challenging. Whilst several surgical techniques have been described, few have reported long term supporting data. A proximal femoral allograft (PFA) may be used to reconstitute bone stock in the multiply revised femur with segmental bone loss of greater than 8 cm. This study reports the outcome of largest case series of PFA used in revision hip arthroplasty. Methods. Data was prospectively collected from a consecutive series of 69 revision hip cases incorporating PFA and retrospective analyzed. Allografts of greater than 8 cm in length (average 14cm) implanted to replace deficient bone stock during revision hip surgery between 1984 and 2000 were included. The average age at surgery was 56 years (range 32–84) with a minimum follow up of 10 years and a mean of 15.8 years (range). Results. From the original cohort four patients had died with the original PFA, 21 (30.4%) patients required further surgery with 14 (20.3%) of these needing revisions of the femoral component. The mean time to femoral revision was 9.5 years and Kaplan-Meier survivorship analysis demonstrates a 79.9% PFA survivorship at 20 years. Discussion. Proximal femoral allograft affords long lasting reconstruction of the femoral component in revision hip surgery. We advocate PFA as an attractive option in the reconstruction of the hip in the presence of significant segmental bone loss in younger patients


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 388 - 388
1 Jul 2010
Westerman R Slack R
Full Access

Introduction: In a climate of tightening budgets and rising cost the pressure on those performing complex and expensive surgery is ever increasing. Patients requiring revision hip surgery are a particular burden on such limited resources. Hospital trusts are dependent upon adequate remuneration for such complex procedures, a process reliant on accurate coding. Methods: We performed a retrospective audit of our coding for revision hip surgery. This highlighted significant shortfalls in the coding process. We implemented necessary changes prior to a further prospective audit. Results: The primary procedure was correctly coded in all our cases throughout, creating a standard tariff (mean £6,897). However certain procedures enable an additional tariff uplift of up to 70%. Yet these additional procedures (performed in 81% of our procedures) had not been coded; loosing these additional tariff uplifts of 70%. We involved and educated our coding staff, creating a ‘tick box’ sticker to be placed on every revision hip operation-record and completed by the operating surgeon. Our subsequent tariff uplifts for these procedures have been significant. Discussion: Joint replacement surgery is being performed in an ever younger and more active population. Patients are increasingly likely to outlive their prosthesis and peri-prosthetic fracture rates are set to continue rising. In the modern NHS, surgeons must have a good understanding of complex tariffs. Coding staff are a notoriously poorly paid and undervalued component of any Hospital Trust, and invariably lack the surgical experience to interpret complex procedures. Trusts must take measures to ensure such large tariff uplifts are not missed for complex procedures. We explain the tariff process and discuss how improvements can easily be achieved by individual trusts


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 164 - 164
1 Sep 2012
Pelet S Côté M Denault A Provost J
Full Access

Purpose. Tape blisters after hip surgery are frequent. There are source of pain, an obstacle for rapid rehabilitation and an open door for infection. Previous studies have shown a reduction up to 10% according to the type of bandage. A previous survey in our hospital demonstrated more than 50% of patients presenting tape blisters with the use of Hypafix. The purpose of this prospective study was to compare the prevalence of blisters with the use of three different kinds of bandages. Method. Between April and December 2009, 150 patients admitted for hip surgery (THR, hip fractures) were randomized in three groups: Hypafix (control group), silicone gel (Mepilex Border), perforated plaster (Mepore Pro). Groups were similar for demographic datas and type of surgery. Main outcome is tape blisters during hospital stay. Additional observations were duration of hospital stay, costs related to bandages and nursing cares. Outpatient records were completed by nurses and patients and returned to research team after complete wound healing. Results. 149 patients completed follow-up, one patient was excluded because of cancelled surgery. The blister prevalence in the silicone group is of 3% and significantly lower than the Mepore Pro (59%, p<0,01) and the Hypafix group (63%, p<0,01). Blisters appear in the first two days after surgery. There is no relationship with the type of surgery. Hospital stay was similar in all groups. 45% of outpatient records were obtained. Silicone gel bandage is cost effective: even if more expensive, it required less nursing cares during hospital stay and after returning home. Conclusion. The silicone gel bandage (Mepilex border) is associated with only 3% of tape blisters and really more effective than the two other bandages. It is even more effective than bandages described in the literature. It is also cost effective and doesnt require outpatient cares. The silicone bandage is associated with an important reduction of tape blisters after hip surgery, with the lower rate observed in the literature


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 53 - 53
1 Mar 2009
Bailie G Howell J Hubble M Timperley J Gie G
Full Access

Introduction: Recurrent dislocation is a significant problem after total hip replacement. Aetiology is multifactorial and treatment should address the reason for dislocation. The use of a constrained tripolar liner is an option in the surgical treatment of dislocation. Methods: A retrospective review was carried out of patients who have undergone revision hip surgery and had a constrained liner cemented into the acetabulum. Patients were identified from a computer database. All patients had a constrained liner cemented onto a satisfactory pre-existing cement mantle, cemented into a reconstruction ring, or cemented into a well fixed cementless shell. The Osteonics Tripolar Liner was used in all cases and the outer aspect of the tripolar liner was prepared with a burr to create grooves and thus improve cement interlock. Data collected included demographics, reason for revision, components used, re-revision rate, outcome and survival. Results: There were 58 cases identified where a cemented constrained liner was inserted at revision hip surgery. Average age at time of surgery was 77years (range 40–94). Reason for use of a constrained liner was recurrent dislocation in over 95% of cases. There were 9 patients who died with less than 2 years follow-up; they were excluded, leaving a study group of 49 cases. Average duration of follow-up was 46months (range 24–76). There have been 4 infections, one of which required removal of prostheses and 2 stage revision. There was one case of fall post-operatively and fracture of the contra-lateral femoral neck. There have been 3 implant failures requiring re-revision. All failures were due to disarticulation of the liner, 2 of which occurred in the same patient on separate occasions. There have been no revisions for loosening, and there have been no cases of failure at the bone-cement interface or at the cement-cement interface with the cement-in-cement technique. Overall survival of the cemented constrained liner was 91.8% at average 3.8years. Conclusion: This study demonstrates that a cemented constrained tripolar liner is a viable option in revision hip surgery, particularly in the treatment of recurrent dislocation


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 534 - 534
1 Aug 2008
Bailie AG Howell JR Hubble MJ Timperley AJ Gie GA
Full Access

Introduction: Recurrent dislocation can be a significant problem after total hip replacement. The use of a constrained tripolar liner is an option in the surgical treatment of dislocation or instability. Methods: A retrospective review was carried out of patients identified from a prospective database. All patients had a constrained liner cemented onto a satisfactory pre-existing cement mantle, cemented into a reconstruction ring, or cemented into a well fixed cementless shell. The Osteonics Tripolar Liner was used in all cases; the outer aspect of the liner was prepared with a burr to create grooves and thus improve cement interlock. Data collected included demographics, reason for revision, re-revision rate, outcome and survival. Results: There were 58 cases identified where a cemented constrained liner was inserted at revision hip surgery. Average age at time of surgery was 77years (range 40–94). There were 9 patients who died with less than 2 years follow-up; they were excluded, leaving a study group of 49 cases. No cases were lost to follow-up. Average duration of follow-up was 46months (range 24–76). There have been 4 infections, one of which required removal of prostheses and a 2-stage revision. There was one case of fall post-operatively and fracture of the contra-lateral femoral neck. There have been 4 implant failures requiring re-revision. All failures were due to disarticulation of the liner, 2 of which occurred in the same patient on separate occasions. There have been no revisions for loosening, and there have been no cases of failure at the bone-cement interface or at the cement-cement interface with the cement-in-cement technique. Overall survival of the cemented constrained liner was 90% at average 3.8years. Conclusion: This study demonstrates that cementing a constrained liner into the acetabulum is a viable option in revision hip surgery, particularly in the management of instability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 25 - 25
1 Jun 2016
Ferguson D Henckel J Holme T Berber R Matthews W Carrington R Miles J Mitchell P Jagiello J Skinner J Hart A
Full Access

Introduction. Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 2013. 1,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty. Patient/Materials & Methods. A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire. Results. 91% of respondents rated overall course satisfaction good or very good with 100% stating learning objectives were met or exceeded. 100% of delegates rated the bone model workshop cases as good or very good for the acetabular course, and 88% for the femoral course. Discussion. This course has been shown to enhance learning of surgical techniques and skills in complex hip surgery. Conclusion. We have developed a novel, effective and low cost training simulation method using pathological dry bone models for complex and revision hip arthroplasty which could be developed for other anatomical areas


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 437 - 437
1 Nov 2011
Takahira N Uchiyama K Fukushima K Kawamura T Uchino M Itoman M
Full Access

On the basis of observations made in recent years, it can be inferred that the incidence of venous thromboembolism (VTE) in Japan is as high as that in Western countries. Since 2007, the use of fondaparinux for the prophylaxis of VTE following lower-limb orthopedic surgery has been approved for Japanese patients. This study was performed with an aim to investigate the safety and efficacy of fondaparinux for the prevention of VTE following hip surgery in Japanese patients. From June 2007 to August 2008, we evaluated 141 consecutive patients (148 hips; average age, 65.6) undergoing total hip replacement (THR), consisted of cementless minimally invasive surgery, and hip fracture surgery (HFS), consisted of open reduction and internal fixation or bipolar hemiarthroplasty. We mainly used 2.5 mg of fondaparinux for a period extending up to 14 days. We estimated the symptomatic VTE and asymptomatic deep-vein thrombosis (DVT) rates in patients by ultrasonography performed on preoperative and postoperative day 3. In addition, we evaluated the pre-operative and postoperative plasma D-dimer levels on days 3, 7, and 14. We determined that both the preoperative and postoperative incidence of symptomatic VTE was 0%. A D-dimer value of 20 ug/ml or higher was not observed on preoperative days 3 and 7; however, this value was observed in 2 hips on postoperative day 14. The incidence of asymptomatic DVT was observed to be 0.8% preoperatively and 4% postoperatively. In particular, the corresponding value following HFS was observed to be 7.7% preoperatively. The incidence of the hemorrhagic event was observed to be 14.9%. Bleeding was mostly observed in the surgical and drainage areas. An overall major bleeding incidence of 0.7% (1 patient) was observed. The corresponding value in patients in whom the administration of fondaparinux was discontinued by day 14 was 18.9%. The study results indicate that fondaparinux is useful in Japanese patients for the prevention of VTE following hip surgery. However, the administration of this drug should be accompanied by additional measures to prevent the associated side effect of bleeding


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 177 - 177
1 Mar 2008
Murcia A Suárez M Rodríguez L Acebal G
Full Access

Tantalum is a pure metallic element and is attractive for use in orthopaedic implants because it is one of the most biocompatible metals available for implant fabrication. The potential advantages for the use of porous tantalum in total hip arthroplasty include:. excellent bone and tissue ingrowth observed histologically;. direct polyethylene intrusion into the metal substrate. This allows the elimination of any potential backside wear in the monoblock cup;. The two-piece design consist of a tantalum shell with screw holes for fixation into the dome of the ilium and posterior column. A polyethylene liner is cemented into the tantalum shell to eliminates backside motion. In addition, acetabular augments of porous tantalum have been developed for use in restoration of major bone deficiencies. Prospective study on a case serie of 113 THA’s performed by two surgeons in a single institution. From 2000 to December 2003, 113 hips have undergone arthroplasty using porous tantalum implants consisting of 54 primary hip arthroplasties and 59 revision THA’s. The patients where evaluated clinical and radiographically every 3 month during the first year, and after yearly. Mean patient age was 64,2 years, (range 44–87); with 59% males and 41% females. No patients died or lost to follow-up. No further surgeries of the involved hip. No radiographic signs of loosening of the acetabular component according to the criteria of Hodgkinson et al. No problems specifically from the use of acetabular augments or extra screws has been noted. Of the revision series, a total of 16 cases have received acetabular augments. Complications included 1 superficial infection, 2 dislocations. No vasculonervous complication; and in 2 cases technical difficulties to achieve good fixation due to ethiology of the THA (desarthrodesis). The average Harris hip score improved from 48 to 89 following primary surgery. Tantalum acetabular components for primary and revision hip surgery have performed well for up to 3 years, and have excellent stability. The two-piece acetabular shell and augments permits the reconstruction of every acetabular bone defect


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 160 - 161
1 Mar 2008
Murcia A Suárez M Rodríguez L Acebal G Murcia A
Full Access

Tantalum is a pure metallic element and is attractive for use in orthopaedic implants because it is one of the most biocompatible metals available for implant fabrication. The potential advantages for the use of porous tantalum in total hip arthroplasty include:. excellent bone and tissue in growth observed histologically;. direct polyethylene intrusion into the metal substrate. This allows the elimination of any potential backside wear in the monoblock cup;. The two-piece design consist of a tantalum shell with screw holes for fixation into the dome of the ilium and posterior column. A polyethylene liner is cemented into the tantalum shell to eliminates backside motion. In addition, acetabular augments of porous tantalum have been developed for use in restoration of major bone deficiencies. Prospective study on a case serie of 113 THA’s performed by two surgeons in a single institution. From 2000 to December 2003, 113 hips have undergone arthroplasty using porous tantalum implants consisting of 54 primary hip arthroplasties and 59 revision THA’s. The patients where evaluated clinical and radiographically every 3 month during the first year, and after yearly. Mean patient age was 64,2 years, (range 44–87); with 59% males and 41% females. No patients died or lost to follow-up. No further surgeries of the involved hip. No radiographic signs of loosening of the acetabular component according to the criteria of Hodgkinson et al. No problems specifically from the use of acetabular augments or extra screws has been noted. Of the revision series, a total of 16 cases have received acetabular augments. Complications included 1 superficial infection, 2 dislocations. No vasculo-nervous complication; and in 2 cases technical difficulties to achieve good fixation due to ethiology of the THA (desarthrodesis). The average Harris hip score improved from 48 to 89 following primary surgery. Tantalum acetabular components for primary and revision hip surgery have performed well for up to 3 years, and have excellent stability. The two-piece acetabular shell and augments permits the reconstruction of every acetabular bone defect


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 69 - 69
1 Mar 2006
Trikha S Trikha P Singh S Raynham O Lewis J Mitchell P Edge A
Full Access

We describe the clinical and radiological results of 120 consecutive revision hip replacements in 107 patients, using a titanium alloy femoral component fully coated with Hydroxyapatite ceramic (HAC). The mean age at operation was 71 years (range 36 to 92). The average length of follow up was 8.0 years (range 5.0 to 12.4). All patients receiving a JRI Furlong HAC coated femoral component (JRI Instrumentation Ltd, London, UK) with a minimum follow up of 5 years were included. These included patients on whom previous revision hip joint surgery had taken place. Patients were independently reviewed and scored using the Harris Hip Score (HHS), the Charnley modification of the Merle d’Aubigne and Postel Score (MDP), and The Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). Radiographs were assessed by three reviewers (blinded to clinical details) for new bone formation, osteolysis, osteointegration and radiolucent lines in each Gruen Zone. The mean Harris hip score was 85.8 (range 42 to 100) at the latest post-operative review. The mean WOMAC and MDP scores were 34.5 and 14.8 respectively. The mean pain visual analogue score (range 0 to 10) was 1.2 overall and 0.5 specifically for mid-thigh pain. There were no revisions of any femoral component for aseptic loosening. There were four stem re-revisions (3 cases of infection, 1 recurrent dislocation). Radiological review of all femoral components, including the four mentioned, revealed stable bone ingrowth with no new radiolucent lines in any zone. Using revision or impending revision for aseptic loosening as the end point, at 10 years the cumulative survival for the stem was 100% (95% CI 94 to 100). We present excellent medium to long term clinical, radiological and survivorship results with the use of a fully HAC coated titanium stem in revision hip surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIII | Pages 20 - 20
1 Apr 2012
Talawadekar G Sathyamurthy S
Full Access

Queen Elizabeth the Queen Mother Hospital, Margate, East Kent Hospitals NHS University Trust, UK. PURPOSE. Surfaces of supports used to position patients for hip replacement are usually are in direct contact with the patient skin around the groin/buttock areas & repeated use of same supports, in trauma & elective surgeries, can be a source of cross-infection & wound contamination. MATERIALS AND RESULTS. Swab samples from 12 supports, employed interchangeably for elective & trauma surgery. Cultured & incubated at 37 0 C in Columbia Blood Agar. 2 random supports cleaned using Sani Cloth Detergent non-alcoholic wipes & 2 samples were obtained from each support, 5 min later. 71% sampled supports were contaminated, with Coagulase-negative Staphylococcus, including Staph Epidermidis, being the most commonly grown organism with average of 5.3 colony forming units (CFU) (0-38) per swab. 5 min after cleaning 2 of above supports there was a 100% reduction in their contamination with no growth from the 4 swabs. CONCLUSION. Trauma patients are not necessarily subjected to groin MRSA swabs pre-operatively in contrast to patients undergoing elective hip surgery who are rigorously swabbed for the same & interchangeable use of hip supports in trauma and elective patients defeats the purpose of this practice considering the fact that Coagulase -ve Staphylococci like Staph epidermidis, reside on the hip supports presently used in the orthopaedic theatre. We recommend strict cleaning of these supports for 5 min with the detergent wipes before & between every orthopaedic hip case & where feasible, the supports used should be different for elective and trauma cases


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 314 - 314
1 May 2010
Benthien J Dick W Ganse B
Full Access

Introduction and objective: Infection is one of the greatest threats in hip surgery. It is agreed that the implant should be removed. The debate remains open if one or two stage surgery is perferable. This study evaluates the two stage septic hip revison arthroplasty and compares our results with the literature. Materials and Methods: A retrospective clinical and radiological study was performed on patients that had a two stage septic revision hip surgery. The Harris Hip Score (HHS) and the Mayo Hip Score (MHS) were applied. The ASA-Score for evaluation of preoperative morbidity was introduced. Statistical evaluation included the t–test. Results: 40 patients with 41 primary total hip replacements underwent septic revision. 17 patients with 18 hip prostheses (8 male, 9 female) could be evaluated. 14 patients were deceased, the rest was unable to participate due to severe health problems.12 patientswith 13 hips had a primary reimplantation, 5 patients had to be left with a Girdlestone situation. The mean follow up was 52 months (4.3 years, standard error +/−28). The average age was 68 years. The mean preoperative ASA-Score was 3.24 (+/−0,75). Staph. aureus was the most common infectious agent (35%) followed by Staph epidermidis (24%) and E. coli (12%). The mean time between removal and re-implantation was 158 days. The most frequent primary preoperative indication for hip arthroplasty was osteoarthritis (62%) followed by trauma (24%) and avascular necorsis of the femoral head (14%). In 42%, the onset of ionfection was early (under 12 months after implantation), 58%% of the patients had a late onset infection. The MHS in the group who had a reimplantation was an average of 66/standard error +/−21). The patients with a Girdlestone situation had a HHS that was not significantly lower than the rest (58 in Girdlestone patients, 61 in patients with re-implantation). Discussion: The study demonstrated that our results compare well to those of other studies. It supports the conclusion that two stage septic hip arthroplasty is still an excellent option in septic revision arthroplasty. The preoperative ASA-Score which is not routinely mentioned in other studies showed that many of our patients were critically ill. This may explain the long interval between removal and reimplantation, and it may also be of value to determine wether to re-implant at all costs. This study remarkably demonstrated that patients with resection arthroplasty did not have a significantly lower HHS than those with performed re-implantation. The resection arthroplasty may be considered a valuable solution in clinically very ill patients according to our results. If a second operation considering the ASA -score would be too risky it should be discussed if reimplantation must be achieved


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 11 - 11
1 Jun 2017
Will E Magill N Doherty G Fairhurst C Lundy C Norman-Taylor F
Full Access

Purpose. The purpose of this paper is to describe the outcomes of major hip surgery for children with cerebral palsy and communication difficulties using a validated health related quality of life measure and a validated pain score. Method. Children with hypertonic bilateral cerebral palsy (CP) GMFCS levels IV and V, 2–15 years old, having femoral + /- acetabular osteotomies for hip displacement were included if their ability to communicate necessitated the use of the CPCHILD (Caregiver Priorities and Child Health Index of Life with Disabilities) and PPP (Paediatric Pain Profile). The underlying indication for surgery was a hip migration index of more than 40% . CPCHILD and PPP questionnaires were completed face-to-face with the parents or carers at baseline, at 3 months after surgery and at 6 months after surgery. Results. There were 54 patients with a mean age of 8.8 years (SD 3.6). At baseline the mean CPCHILD was 52.1 (SD 11.8). At 3 months it was 58.5 (SD 13.1; p< 0.001). At 6 months it was 59.4 (SD 12.4; p< 0.001). This paper also describes the changes within each domain of the CPCHILD. At baseline the PPP was 12.7 (SD 7.2); at 3 months the PPP was 9.8 (SD 7.2; p< 0.01); at 6 months the PPP was 9.2 (SD 6.4; p< 0.001). Conclusion. Hip reconstruction for displacement is a major intervention for an often asymptomatic condition. This paper confirms that health related quality of life (measured by the CPCHILD) and pain (measured by the PPP) return to baseline or better than baseline within 3 months of surgery and that this is maintained at 6 months. These results should be reassuring for families and healthcare workers looking after children with severe disability undergoing surgery of this sort


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 57 - 57
1 Dec 2016
Rezapoor M Tan T Maltenfort M Chen A Parvizi J
Full Access

Aim. Different perioperative strategies have been implemented to reduce the devastating burden of infection following arthroplasty. The use of iodophor-impregnated adhesive incise drapes is one such strategy. Despite its wide adoption, there is little proof that this practice leads to a reduction of bacterial colonization. The aim of this randomized, prospective study was to evaluate the efficacy of iodophor-impregnated adhesive drapes for reducing bacterial count at the incision site. Method. A total of 96 patients undergoing open joint preservation procedure of the hip were enrolled in this prospective, randomized clinical trial of iodophor-impregnated adhesive drapes. *. One half of patients (n=48) had iodophor-impregnated adhesive drapes. *. applied to the skin prior to incision and kept on throughout the procedure, while the other half (n=48) underwent the same surgery without the use of iodophor-impregnated adhesive drapes. *. Culture swabs were taken from the surgical site at five different time points during surgery (pre-skin preparation, after skin preparation, post-incision, before subcutaneous closure, and prior to dressing application) and sent for culture and colony counts. Mixed-effects and multiple logistic regression analyses were utilized. Results. Iodophor-impregnated adhesive drapes resulted in a significant reduction of bacterial colonization of the surgical incision. At the conclusion of surgery, 12.5% (6/48) of incisions with iodophor-impregnated adhesive drapes. *. and 27.0% (13/48) without adhesive drapes were positive for bacteria. When controlling for preoperative colonization and other factors, patients without adhesive drapes were significantly more likely to have bacteria present at the incision at the time of closure (odds ratio (OR) 11.88, 95% confidence interval (CI) 1.45–80.00), and at all time-points when swab cultures were taken (OR 2.48, 95% CI 1.00–6.15). Conclusions. Based on this skin sampling study, incise draping significantly reduces the rate of bacterial colonization/contamination during hip surgery. The bacterial count at the skin was extremely high in some patients without iodophor-impregnated adhesive drapes. *. , which raises the possibility that a subsequent surgical site infection or periprosthetic joint infection could likely arise if an implant had been utilized


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 1 - 2
1 Apr 2017
Manktelow ARJ Gehrke T Haddad FS


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 208 - 208
1 May 2006
Jung L Maldyk P Sommer E Wojciechowska B Chorostowska-Wynimko J Bany J Skopinska-Rozewska E
Full Access

Angiogenesis, the growth of new blood vessels from pre-existing vasculature has an obvious and essential role in soft and hard tissue repair. During the wound healing many potential angiogenic factors are released and may be found in circulating blood. The most important are basic fibroblast growth factor (bFGF) and vascular endothelial growth factor (VEGF). Experimental data confirm the important role of VEGF and bFGF in wounds and bone healing. It was proved that heparin and its low-molecular derivatives may interfere with various steps of angiogenesis process. Enoxaparine (En) is frequently used as anticoagulant for prophylaxis of thromboembolic complications. The aim of this study was to evaluate in vivo angiogenic potency and VEGF and bFGF content of sera collected from 7 patients after hip surgery, treated for 14 days with 40 mg of En (Clexane, Aventis) daily. Evaluation of angiogenic activity was performed twice before surgery (before and 1 day after one En dose) and 14 days after surgery. Sera were injected intra-dermally to anaesthetized Bal/c mice and 72 hours later the number of newly-formed blood vessels was counted in dissecting microscope (SIA test). Cytokines concentration was estimated by ELISA. Results: Sera obtained after one En dose presented increase of angiogenic activity (57,3+/− 2,4, n=112, p< 0.01)in comparison to the value before En (44.6 +/− 2.5, n=113 of newly-formed blood vessels. After 14 En doses, further increase was observed (72 +/− 4.9 blood vessels, n= 112). BFGF levels increased after the first En dose, VEGF concentration was significantly higher after 14 injections as compare to the results obtained before or after one injection of En. Conclusion: Beneficial effect of 14-days prophylaxis with enoxaparine on healing process might be expected in patients after hip surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 5 - 5
1 Jul 2020
Marusza C Lazizi M Hoade L Bartlett G Fern E Norton M Middleton R
Full Access

Introduction

Open and arthroscopic hip debridement may be used for treatment of femoral acetabular impingement (FAI). There is a paucity of evidence regarding the efficacy of one over the other.

Aim

To compare survivorship in terms of further surgical procedure at five years, in patients having undergone either arthroscopic or open hip debridement.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 515 - 515
1 Oct 2010
Garcia-Cimbrelo E Cruz-Pardos A Garcia-Rey E
Full Access

Introduction: Severe stress shielding and radiographic cortical changes in the proximal femur are frequent after extensively porous-coated stem in revision surgery. We have analyzed the evolution of the femoral cortex at different levels and related factors. Material and Methods: We assessed 95 extensively porous-coated stems in revision surgery with a minimum 5-year follow-up (Mean 10.2 years). 77 hips were revised due to aseptic loosening and 18 due to periprosthetic fractures. Extended osteotomy was used in 29 hips. No cortical struts were used. Preoperative and postoperative osteoporosis was graded according to Moreland and bone defect according to Paprosky. Femoral cortex width was measured at different levels in the immediate postoperative radiograph, at 3, 6 and 12 months and at the last follow-up. Results: There were 2 re-revisions for aseptic loosening. Radiographic ingrowth fixation was more frequent in minor intraoperative bone defects (p=0.011). Preoperative osteoporosis was related to the width of the medial and lateral cortex. Medial cortical thickness increased at different levels with a mean increase of 13.4% (p< 0.001) and the lateral cortical thickness showed a mean decrease of 2.7% at the proximal level. The femoral medial cortex tended to show a higher slope trend in periprosthetic fractures (p=0.015). The outside femoral diameter increased more rapidaly with an extended trochanteric osteotomy (p=0.007). The slope trend of the lateral and medial cortex was significantly higher at proximal levels in hips with a 10-inch stem (p=0.015). Conclusions: Although without clinical relevance at the end of follow-up, femoral medial cortical thickness increased while frequently lateral cortical thickness decreased over time after an extensively porous -coated stem in revision hip surgery


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 297 - 297
1 Jul 2008
Shah GJ Ghazanfar O Shah S Singer GC
Full Access

Introduction: Serum inflammatory markers are routinely used as pre assessment investigation before the revision hip surgery. Various investigations are used to aid in diagnosis of infection in the revision prosthetic hip replacement including aspiration, broad range PCR, bone scan and serum interleukin- 6. Materials and Methods: 256 consecutive revision total hip replacements were assessed for the value of pre operative ESR and c-reactive proteins (CRP) in predicting the deep infections. All patients were evaluated prior to surgery. The patients with coexisting inflammatory disease or peri-prosthetic fracture were also evaluated. A hip was diagnosed as infected on the basis of positive intra operative microbiology samples three or more out of five and or histological evidence. Results: Using the values of ESR > 35 mm/1. st. hour and CRP> 10mg/l, the positive predictive value (either /or) was 56% and the negative predictive value was 96%. 14 patients had an underlying inflammatory arthritis and 5 were peri prosthetic fractures. The inflammatory markers tended to be elevated in these patients. Excluding these 19 patients and using the same criteria, the positive predictive value was 65% and the negative predictive value was 97%. Discussion: We conclude that a CRP< 10 mg/l and ESR < 35 mm/1. st. hour are very useful in excluding infection (negative predictive value of 97%, excluding peri-prosthetic fractures and inflammatory joint disease), but raised inflammatory markers are less accurate in predicting infection


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 32 - 32
1 Dec 2017
Gieseler O Alvarez-Gomez J Roth H Wahrburg J
Full Access

Total hip replacement in Germany has been performed in 227293 cases in 2015 and tendency is increasing. Although it is a standard intervention, freehand positioning of cup protheses has frequently poor accuracy. Image-based and image-free navigation systems improve the accuracy but most of them provide target positions as alphanumeric values on large-size screens beneath the patient site. In this case the surgeon always has to move his head frequently to change his eye-focus between incision and display to capture the target values. Already published studies using e.g. IPod-based displays or LED ring displays, show the chance for improvement by alternative approaches. Therefore, we propose a novel solution for an instrument-mounted small display in order to visualise intuitive instructions for instrument guidance directly in the viewing area of the surgeon.

For this purpose a solution consisting of a MicroView OLED display with integrated Arduino microcontroller, equipped with a Bluetooth interface as well as a battery has been developed. We have used an optical tracking system and our custom-designed navigation software to track surgical instruments equipped with reference bodies to acquire the input for the mini-display. The first implementation of the display is adapted to total hip replacement and focuses on assistance while reaming the acetabulum. In this case the reamer has to be centred to the middle point of the acetabular rim circle and its rotation axis must be aligned to the acetabular centre axis by Hakki. By means of these references the actual deviations between instrument and target pose are calculated and indicated. The display contains a cross-hair indicator for current position, two bubble level bars for angular deviation and a square in square indicator for depth control. All display parts are furnished with an adaptive variable scale. Highest possible resolution is 0.5 degrees angular, 1 millimeter for position and depth resolution is set to 2 mm.

Compared to existing approaches for instrument-mounted displays, the small display of our solution offers high flexibility to adjust the mounting position such that it is best visible for the surgeon while not constraining instrument handling. Despite the small size, the proposed visualisation symbols provide all information for instrument positioning in an intuitive way.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 67 - 67
1 Dec 2022
You D Korley R Duffy P Martin R Dodd A Buckley R Soo A Schneider P
Full Access

Prolonged bedrest in hospitalized patients is a major risk factor for venous thromboembolism (VTE), especially in high risk patients with hip fracture. Thrombelastography (TEG) is a whole blood viscoelastic hemostatic assay with evidence that an elevated maximal amplitude (MA), a measure of clot strength, is predictive of VTE in orthopaedic trauma patients. The objective of this study was to compare the TEG MA parameter between patients with hip fracture who were more mobile post-operatively and discharged from hospital early to patients with hip fracture with reduced mobility and prolonged hospitalizations post-operatively. In this prospective cohort study, TEG analysis was performed in patients with hip fracture every 24-hours from admission until post-operative day (POD) 5, then at 2- and 6-weeks post-operatively. Hypercoagulability was defined by MA > 65. Patients were divided into an early (within 5-day) and late (after 5-day) discharge group, inpatient at 2-weeks group, and discharge to MSK rehabilitation (MSK rehab), and long term care (LTC) groups. Two-sample t-test was used to analyze differences in MA between the early discharge and less mobile groups. All statistical tests were two-sided, and p-values < 0.05 were considered statistically significant. In total, 121 patients with a median age of 81.0 were included. Patients in the early discharge group (n=15) were younger (median age 64.0) and more likely to ambulate without gait aids pre-injury (86.7%) compared to patients in the late discharge group (n=105), inpatients at 2-weeks (n=48), discharged to MSK rehab (n=30), and LTC (n=20). At two weeks post-operative, the early discharge group was significantly less hypercoagulable (MA=68.9, SD 3.0) compared to patients in the other four groups. At 6-weeks post-operative, the early discharge group was the only group to demonstrate a trend towards mean MA below the MA > 65 hypercoagulable threshold (MA=64.4, p=0.45). Symptomatic VTE events were detected in three patients (2.5%) post-operatively. All three patients had hospitalizations longer than five days after surgery. In conclusion, our analysis of hypercoagulability secondary to reduced post-operative mobility demonstrates that patients with hip fracture who were able to mobilize independently sooner after hip fracture surgery, have a reduced peak hypercoagulable state. In addition, there is a trend towards earlier return to normal coagulation status as determined by the TEG MA parameter. Post-operative mobility status may play a role in determining individualized duration of thromboprophylaxis following hip fracture surgery. Future studies comparing TEG to clinically validated mobility tools may more closely evaluate the contribution of venous stasis due to reduced mobility on hypercoagulation following hip fracture surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 106 - 106
1 Dec 2022
You D Korley R Duffy P Martin R Dodd A Buckley R Soo A Schneider P
Full Access

Prolonged bedrest in hospitalized patients is a major risk factor for venous thromboembolism (VTE), especially in high risk patients with hip fracture. Thrombelastography (TEG) is a whole blood viscoelastic hemostatic assay with evidence that an elevated maximal amplitude (MA), a measure of clot strength, is predictive of VTE in orthopaedic trauma patients. The objective of this study was to compare the TEG MA parameter between patients with hip fracture who were more mobile post-operatively and discharged from hospital early to patients with hip fracture with reduced mobility and prolonged hospitalizations post-operatively. In this prospective cohort study, TEG analysis was performed in patients with hip fracture every 24-hours from admission until post-operative day (POD) 5, then at 2- and 6-weeks post-operatively. Hypercoagulability was defined by MA > 65. Patients were divided into an early (within 5-day) and late (after 5-day) discharge group, inpatient at 2-weeks group, and discharge to MSK rehabilitation (MSK rehab), and long term care (LTC) groups. Two-sample t-test was used to analyze differences in MA between the early discharge and less mobile groups. All statistical tests were two-sided, and p-values < 0.05 were considered statistically significant. In total, 121 patients with a median age of 81.0 were included. Patients in the early discharge group (n=15) were younger (median age 64.0) and more likely to ambulate without gait aids pre-injury (86.7%) compared to patients in the late discharge group (n=105), inpatients at 2-weeks (n=48), discharged to MSK rehab (n=30), and LTC (n=20). At two weeks post-operative, the early discharge group was significantly less hypercoagulable (MA=68.9, SD 3.0) compared to patients in the other four groups. At 6-weeks post-operative, the early discharge group was the only group to demonstrate a trend towards mean MA below the MA > 65 hypercoagulable threshold (MA=64.4, p=0.45). Symptomatic VTE events were detected in three patients (2.5%) post-operatively. All three patients had hospitalizations longer than five days after surgery. In conclusion, our analysis of hypercoagulability secondary to reduced post-operative mobility demonstrates that patients with hip fracture who were able to mobilize independently sooner after hip fracture surgery, have a reduced peak hypercoagulable state. In addition, there is a trend towards earlier return to normal coagulation status as determined by the TEG MA parameter. Post-operative mobility status may play a role in determining individualized duration of thromboprophylaxis following hip fracture surgery. Future studies comparing TEG to clinically validated mobility tools may more closely evaluate the contribution of venous stasis due to reduced mobility on hypercoagulation following hip fracture surgery


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 34 - 34
1 Jun 2018
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case-based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 68 - 68
1 Jan 2004
Wall OR Duffy D Macdonald DA
Full Access

Abstract We have prospectively analysed a single-surgeon series of 35 consecutive revision THRs with AAOS bone loss grade II–III, requiring morcelised allograft (ethylene oxide sterilised) for acetabular defects. Patients have been followed up for a minimum of 5 years. Although the results are encouraging, we are observing migration patterns in some cases. Method Twenty-one patients were eligible for final analysis (follow-up for at least 5 years, range 5 to 10 years). Follow-up has consisted of clinical assessment (Charnley activity, pain, function, satisfaction) and a radiographic assessment (AP X-ray) of the replacement hip. Our study end-points are 1) prosthesis revision and, 2) acetabular cup migration at last follow-up. Results There were 6 deaths with less than 5 years follow-up (unrelated causes) and 2 cases have been lost to subsequent follow-up. Two cases had deep infection (revised to a girdlestones procedure at 9 months and 2 years respectively) and there were no early dislocations. One case underwent further revision at 4 years follow-up due to symptomatic (superior) cup migration and three cases are awaiting imminent out-patient assessment. Twenty-one cases have had a mean follow-up of 5.83 years. Eight cases (23%) have shown no cup migration. Five have shown only late stage migration, 4 cases have shown both initial and then late migration whilst 3 cases have shown only intermediate migration followed by stability. One case has shown progressive migration throughout follow-up. All 13 cases (37%) exhibiting migration are still asymptomatic. Conclusion Our results show that use of morcelised acetabular allograft for revision hip surgery with deficient medial and superior acetabular wall is a useful surgical procedure. Our results over a minimum of 5 years follow-up are comparable to others in this field. However, the relatively high number of revision cases from our data which have shown, as yet, asymptomatic cup migration causes concern for future management of these patients. It is imperative that all such cases have regular (annual) indefinite follow-up. We are concerned that further cases may present with acetabular cup migration in view of our results


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 297 - 297
1 Jul 2008
Phillips S Chavan R Porter M Kay P Hodgkinson Purbach B Hoad Reddick A Frayne J
Full Access

Introduction: We performed a retrospective case control study in 80 patients who under went revision hip surgery at our unit. Methodology: Group A (40 patients), received tranexamic acid and intra-operative cell salvage. Group B (40 patients) a matched control did not receive these treatments. Each group was divided into 4 sub groups; revision of both components, revision of components + bone grafting, revision acetabular component +/− bone grafting and revision femoral component +/− bone graft. Results: In group A the total number of units transfused was 139 compared to 52 in group B. This represents a reduction in blood usage of 37%. The mean amount of blood transfused from cell salvage in each group was 858mls, 477mls, 228mls and 464mls. There was a significant difference in the amount of blood returned between the groups (p< 0.0001). In the control group 37 patients needed transfusion, in the study group 22 (p< 0.0001). At our unit a cost analysis calculation has shown total revenue saving of £88,000 and a potential saving throughout the trust of £316,688 per year. Discussion: To our knowledge this is the first study to examine the use of cell salvage and tranexamic acid in revision hip surgery. Our results show that a significant reduction in blood transfusion can be made using this technique. It is vital that blood conserving strategies are developed so that future revision surgery can continue


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 74 - 75
1 Mar 2009
Shah G shah S Singer G Ghazanfar O
Full Access

Introduction: Serum inflammatory markers are routinely used as pre assessment investigation before the revision hip surgery. Various investigations are used to aid in diagnosis of infection in the revision prosthetic hip replacement including aspiration, broad range PCR, bone scan and serum interleukin- 6. Materials and Methods: 256 consecutive revision total hip replacements were assessed for the value of pre operative ESR and c-reactive proteins (CRP) in predicting the deep infections. All patients were evaluated prior to surgery. The patients with coexisting inflammatory disease or peri-prosthetic fracture were also evaluated. A hip was diagnosed as infected on the basis of positive intra operative microbiology samples three or more out of five and or histological evidence. Results: Using the values of ESR > 35 mm/1st hour and CRP> 10mg/l, the positive predictive value (either/or) was 56% and the negative predictive value was 96%. 14 patients had an underlying inflammatory arthritis and 5 were peri prosthetic fractures. The inflammatory markers tended to be elevated in these patients. Excluding these 19 patients and using the same criteria, the positive predictive value was 65% and the negative predictive value was 97%. Discussion: We conclude that a CRP< 10 mg/l and ESR < 35 mm/1st hour are very useful in excluding infection(negative predictive value of 97%, excluding peri-prosthetic fractures and inflammatory joint disease). But raised inflammatory markers are less accurate in predicting infection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 94 - 94
17 Apr 2023
Gupta P Butt S Dasari K Galhoum A Nandhara G
Full Access

The Nottingham Hip Fracture Score (NHFS) was developed in 2007 as a predictor of 30-day mortality after hip fracture surgery following a neck of femur fracture. The National Hip Fracture Database is the standard used which calculated their own score using national data. The NHF score for 30-day mortality was calculated for 50 patients presenting with a fractured neck femur injury between January 2020 to March 2020. A score <5 was classified as low risk and >/=5 as high risk. Aim was to assess the accuracy in calculating the Nottingham Hip Fracture Score against the National Hip Fracture Database. To explore whether it should it be routinely included during initial assessment to aid clinical management?. There was an increase in the number of mortalities observed in patients who belonged to the high-risk group (>=5) compared to the low risk group. COVID-19 positive patients had worse outcomes with average 30-day mortality of 6.78 compared to the average of 6.06. GEH NHF score per month showed significant accuracy against the NHFD scores. The identification of high-risk groups from their NHF score can allow for targeted optimisations and elucidation of risk factors easily gathered at the point of hospitalisation. The NHFS is a valuable tool and useful predictor to stratify the risk of 30-day mortality and 1-year mortality after hip fracture surgery. Inclusion of the score should be considered as mandatory Trust policy for neck of femur fracture patients to aid clinical management and improve patient safety overall


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 274 - 274
1 Mar 2004
Owers K DiMascio L Ware H
Full Access

Aims: Remaining bone stock at revision total hip arthroplasty (THA) determines the procedure and is related to outcome. This study was carried out to determine the radiological effect on bone stock of patients waiting for surgery. Methods: The hospital notes and AP pelvic radiographs of all (19) patients (22 hips) who underwent revision surgery for symptomatic aseptic loosening of a heterogeneous group of THAs over the last 2 years were obtained. The Hahnemann University Hospital (HUH) Classification and Staging System for Revision THA (a purely radiological classification that evaluates both the acetabular and the femoral bone stock, any component instability and sepsis and that correlates well with functional outcome) was used to evaluate bone stock on the initial clinic and the immediate preoperative radiographs. The effect of delay on the planned procedure was also recorded. Results: The average time delay for all patients was 57 weeks. 12/22 hips deteriorated radiologically by an average of 1.3 points (range 1–3) on the HUH Classification. In 7/12 it altered the procedure to be carried out. Conclusions: This preliminary study suggests that a delay to revision hip surgery is associated with a reduction in bone stock and hence potential functional outcome. It can also detrimentally affect the planned procedure. This study reinforces the need for minimal delay in symptomatic patients with aseptic loosening of THA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 34 - 34
1 Apr 2017
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case-based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 246 - 246
1 May 2006
White SP Smith EJ
Full Access

There is a strong drive from industry, patients and the media to offer minimal access hip surgery (MAS) for joint arthroplasty. There is a plethora of definitions, implants, specialist instrumentation and techniques available. Confusion reigns as to the definition, who should offer it, which approach should be used, and what training should be undertaken. Method : All Consultant Orthopaedic Surgeons in the United Kingdom were sent a simple questionnaire asking for MAS training undertaken, evidence of specialisation, volume of minimal access cases performed, availability of specialist instrumentation, approach used and definition of mimimal access surgery. Results : 23% of those performing hip arthroplasty had performed MAS. The majority performed between 1–5 cases last year. 41% had observed MAS. Of those with a specialist interest in hip arthroplasty, 37% had performed MAS. Of those performing MAS, 83% had observed another surgeon and 60% had attended a course. 29% of consultants intend to perform MAS in the future. The mean and mode quoted length of a regular total hip arthroplasty scar was 15.4 and 15cm respectively. The mean and mode quoted length of a MAS scar was 9.7 and 10 cm respectively. 75% used the miniposterior approach. Relationships with specialisation, British Hip Society membership and volume breakdown are discussed. Conclusion: MAS is a popular technique although currently small case numbers are being performed. Given the level of interest in the technique, the definition and training required need to be clarified, and the clinical outcome requires close monitoring to ensure that standards of implantation are not jeopardised


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 60 - 60
1 Oct 2018
Fleischman AN Tarabichi M Makar G Foltz C Hozack WJ Austin MS Chen AF
Full Access

Background

Orthopedic surgeons have relied heavily on opiates after total hip replacement (THR) despite no clear evidence of benefit and a rapidly growing abuse epidemic. Multimodal analgesia may reduce or even obviate the need for opiates after elective surgery.

Methods

In a cluster-randomized, crossover trial, 235 patients undergoing THR were assigned to receive multimodal analgesia with minimal opiates (Group A-10 tablets), multimodal analgesia with a full opiate supply (Group B-60 tablets), or a traditional opiate regimen without multimodal analgesia (Group C-60 tablets). The multimodal regimen comprised scheduled-dose acetaminophen, meloxicam, and gabapentin. Primary outcomes were daily pain and opiate utilization for the first 30-days. Secondary outcomes included assessments of satisfaction, sleep-quality, opiate-related symptoms, hip function, and adverse events.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 398 - 399
1 Jul 2010
Jones A New A Bolland B Oreffo R Dunlop D
Full Access

Introduction: Impaction bone grafting (IBG) for revision hip surgery can be a difficult surgical skill with a fine line between construct failure from insufficient compaction and intraoperative fracture from high impaction forces. Following on from our experience in the femur, in this study we used an acetabular model to test the hypothesis that the use of vibration for IBG could reduce the peak stresses thus reducing the intraoperative fracture risk and also improve the reliability and reproducibility of the impaction technique. Methods: Revision hemi pelvis models were made (Pra-prosky Type 2a). A standard impaction technique was used for the control group, and the impactor tamps were coupled with a pneumatic hammer for the vibration group. The cavity was filled in 6 set steps with strain gauge readings taken throughout. The pelvis construct was then mechanically loaded. Graft compaction and micro motion post mechanical testing was assessed with micro CT. Results: Vibration impaction led to a significant reduction (p=0.03) in the peak stresses during the impaction process. There was also significantly less variability in peak stresses for the vibration group compared to standard, both in sequential impactions by the same surgeon and between different surgeons. One medial wall fracture occurred in the control group only, similar to fractures encountered in the clinical situation. There was no significant difference in the degree of graft compaction or in the subsidence of the cup. Discussion: We believe that this new technique of applying vibration to the IBG process can reduce the risk of intraoperative fracture whilst achieving good graft compaction and implant stability. This technique therefore has the potential to widen the ‘safety margins’ of IBG and reduce the learning curve allowing more widespread adoption of the technique for replacing lost bone stock


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 189 - 194
1 Feb 2024
Donald N Eniola G Deierl K

Aims. Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative blood pressure, there are limited studies examining pre- and postoperative blood pressure. Methods. We conducted a prospective observational cohort study over a one-year period from December 2021 to December 2022. Patient demographic details, biochemical results, and haemodynamic observations were taken from electronic medical records. Statistical analysis was conducted with the Cox proportional hazards model, and the effects of independent variables estimated with the Wald statistic. Kaplan-Meier survival curves were estimated with the log-rank test. Results. A total of 528 patients were identified as suitable for inclusion. On multivariate analysis, postoperative hypotension of a systolic blood pressure (SBP) < 90 mmHg two to 24 hours after surgery showed an increased hazard ratio (HR) for 30-day mortality (HR 4.6 (95% confidence interval (CI) 2.3 to 8.9); p < 0.001) and was an independent risk factor accounting for sex (HR 2.7 (95% CI 1.4 to 5.2); p = 0.003), age (HR 1.1 (95% CI 1.0 to 1.1); p = 0.016), American Society of Anesthesiologists grade (HR 2.7 (95% CI 1.5 to 4.6); p < 0.001), time to theatre > 24 hours (HR 2.1 (95% CI 1.1 to 4.2); p = 0.025), and preoperative anaemia (HR 2.3 (95% CI 1.0 to 5.2); p = 0.043). A preoperative SBP of < 120 mmHg was close to achieving significance (HR 1.9 (95% CI 0.99 to 3.6); p = 0.052). Conclusion. Our study is the first to demonstrate that postoperative hypotension within the first 24 hours is an independent risk factor for 30-day mortality after hip fracture surgery. Clinicians should recognize patients who have a SBP of < 90 mmHg in the early postoperative period, and be aware of the increased mortality risk in this specific cohort who may benefit from a closer level of monitoring and early intervention. Cite this article: Bone Joint J 2024;106-B(2):189–194


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 34 - 34
1 Dec 2016
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case-based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 92 - 92
1 Nov 2016
Lombardi A
Full Access

Not all total hip arthroplasty cases are created equal is a maxim that holds true for both primary and revision scenarios. Complex cases involve patients presenting with compromised bone and/or soft tissue. For primary cases, these include hips with dysplasia, ankylosis, deformed proximal femora, protrusio acetabuli, prior hip fracture with or without failed fixation, previous bony procedures, or neuromuscular conditions. In revision surgery, complex scenarios include cases compromised by bone loss, deterioration of the soft tissues and resulting in dislocation and instability, peri-prosthetic fracture, leg length discrepancy, infection, and more recently, hypersensitivity reactions. Meticulous surgical technique including component placement is essential. In this interactive session, a moderator and team of experts will discuss strategies for evaluation and management of a variety of challenging hip case scenarios.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1384 - 1391
3 Oct 2020
Yoo S Jang EJ Jo J Jo JG Nam S Kim H Lee H Ryu HG

Aims. Hospital case volume is shown to be associated with postoperative outcomes in various types of surgery. However, conflicting results of volume-outcome relationship have been reported in hip fracture surgery. This retrospective cohort study aimed to evaluate the association between hospital case volume and postoperative outcomes in patients who had hip fracture surgery. We hypothesized that higher case volume would be associated with lower risk of in-hospital and one-year mortality after hip fracture surgery. Methods. Data for all patients who underwent surgery for hip fracture from January 2008 to December 2016 were extracted from the Korean National Healthcare Insurance Service database. According to mean annual case volume of surgery for hip fracture, hospitals were classified into very low (< 30 cases/year), low (30 to 50 cases/year), intermediate (50 to 100 cases/year), high (100 to 150 cases/year), or very high (> 150 cases/year) groups. The association between hospital case volume and in-hospital mortality or one-year mortality was assessed using the logistic regression model to adjust for age, sex, type of fracture, type of anaesthesia, transfusion, comorbidities, and year of surgery. Results. Between January 2008 and December 2016, 269,535 patients underwent hip fracture surgery in 1,567 hospitals in Korea. Compared to hospitals with very high volume, in-hospital mortality rates were significantly higher in those with high volume (odds ratio (OR) 1.10, 95% confidence interval ((CI) 1.02 to 1.17, p = 0.011), low volume (OR 1.22, 95% CI 1.14 to 1.32, p < 0.001), and very low volume (OR 1.25, 95% CI 1.16 to 1.34, p < 0.001). Similarly, hospitals with lower case volume showed higher one-year mortality rates compared to hospitals with very high case volume (low volume group, OR 1.15, 95% CI 1.11 to 1.19, p < 0.001; very low volume group, OR 1.10, 95% CI 1.07 to 1.14, p < 0.001). Conclusion. Higher hospital case volume of hip fracture surgery was associated with lower in-hospital mortality and one-year mortality in a dose-response fashion. Cite this article: Bone Joint J 2020;102-B(10):1384–1391


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 567 - 568
1 May 2014
K. Graham H Narayanan UG


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 30 - 30
1 Feb 2017
Barnes L
Full Access

Background

The use of tranexamic acid (TEA) can significantly reduce the need for allogenic blood transfusions in elective primary joint arthroplasty. Revision total hip arthroplasty requires increased utilization of post-operative blood transfusions for acute blood loss anemia compared to elective primary hip replacement. There is limited literature to support the routine use of TEA in revision THA.

Methods

We performed a retrospective review of 161 consecutive patients who underwent revision total hip arthroplasty from 2012–14 at a single institution by two fellowship-trained surgeons. We compared the transfusion requirements and the post-operative hemoglobin drop of the TEA Group (109 patients, 114 hips) versus the No TEA group (52 patients, 56 hips). Our standard protocol for administering TEA is 1000mg IV at incision, and the same dose repeated two hours later. The No TEA group did not receive the medication because of previous hospital contraindication criteria.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 308 - 308
1 May 2010
Philippot R Delangle F Verdot F Farizon F
Full Access

Introduction: Many publications have already shown the great interest of dual-mobility concept which significantly reduces the rate of prosthetic dislocation and thus find its place for patients at high risk of post operative instability. The aim of our study is to evaluate the prevalence of prosthetic instability in revision total hip arthroplasty using a dualmobility cup. Materials and Methods: Our multicentric series consists of 163 revision total hip arthroplasties performed between may 1999 and may 2004. The mean age at revision was 70 years and the mean follow-up period was 56 months. The primary etiology necessitating revision is aseptic loosening. According to the SOFCOT classification, the acetabular deficiency was grade IV 9 times, grade III 47 times, grade I or II 107 times. All the implanted acetabular components are SERF dual-mobility implants. This system consists of a metal back which can be HA-coated and Press Fit or cemented in a Kerboull cross or in a Novae Arm. The mobile-bearing insert which allows a dual articulation between the head and the metal back is of polyethylene. We implanted 119 HA-coated press-fit cups and cemented 44 dual-mobility cups in a support ring or in a Kerboull cross. Results: The mean Merle d’Aubigné and Postel score is 14,1 at the last follow-up and 4,2 in the preoperative period. We reported 8 complications: 6 early dislocations and 2 acetabular revisions for secondary mobilisation of the cup. Discussion: According to Huten’s 1996 SOFCOT teaching conference, this rate ranges between 2 and 5% and we have already published a series of 106 dual-mobility with no dislocation at a 10 year follow-up period. With 4% dislocations at a mean follow-up of 56 months, the dual-mobility cup seems to provide high stability in revision hip surgery when other factors such as muscular deficiency, extended synovectomies, difficult implant placement, encourage an uncertain postoperative prosthetic stability. These results have to be compared to those of other systems such as constrained acetabular cups or tripolar cups. Conclusion: This is why dual-mobility remains an efficient and reliable choice to avoid prosthetic dislocation in revision surgery. Moreover, we encourage the use of dual-mobility cup in any high risk situation in terms of post-operative instability such as for old or neurological patients


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 557 - 558
1 Aug 2008
Wahrburg J
Full Access

The paper presents the design of a mechatronic assistance system which started from the novel concept to integrate an optical navigation system and a robotic arm, combining the specific advantages of each of the two components. The integrated system offers precise positioning and guiding of surgical instruments according to pre-operative planning. A unique feature results from its capability to track small motions of the patient in real time, eliminating the need to rigidly fix the anatomical structure to be operated. The robot arm can be regarded as a controlled machine actuator of a navigation system. Its operation is mainly controlled by interactive operating modes which are based on a versatile haptic interface. The system supports the surgeon in those parts of a procedure where human skills are limited, but always lets him take full control, for example by directly grasping and moving the arm at its wrist if he wants to push the arm aside. In 2003 several clinical trials have been performed to demonstrate the technical and medical feasibility of the approach. Our mechatronic assistance system has been world’s first system to support the implantation of the acetabular cup in robot assisted hip surgery. The next steps have been concentrated on further developments in some key areas. Improvements of the man-machine interface in order to make the operation of the system faster, easier, and more robust, extension of the system application also to the femoral part of total hip replacement, including support for resurfacing implants, investigation of novel tool systems for bone preparation and prosthesis implantation that fully exploit the advantages of mechatronic, slip-away-safe tool guidance, further improvements for less invasive operating techniques. It has turned out that apart from proving the basic system functionality it is a time consuming task to design all system components in a way that they are robust and easy to handle to be acceptable for daily clinical application. After a partial redesign of the system architecture presently the implementation of improved modules to support both the acetabular and the femoral part in total hip replacement surgery by the mechatronic assistance system is in progress


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 97 - 97
1 Nov 2015
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Bone & Joint Research
Vol. 9, Issue 9 | Pages 554 - 562
1 Sep 2020
Masters J Metcalfe D Ha JS Judge A Costa ML

Aims. This study explores the reported rate of surgical site infection (SSI) after hip fracture surgery in published studies concerning patients treated in the UK. Methods. Studies were included if they reported on SSI after any type of surgical treatment for hip fracture. Each study required a minimum of 30 days follow-up and 100 patients. Meta-analysis was undertaken using a random effects model. Heterogeneity was expressed using the I. 2. statistic. Risk of bias was assessed using a modified Newcastle-Ottawa Scale (NOS) system. Results. There were 20 studies reporting data from 88,615 patients. Most were retrospective cohort studies from single centres. The pooled incidence was 2.1% (95% confidence interval (CI) 1.54% to 2.62%) across ‘all types’ of hip fracture surgery. When analyzed by operation type, the SSI incidences were: hemiarthroplasty 2.87% (95% CI 1.99% to 3.75%) and sliding hip screw 1.35% (95% CI 0.78% to 1.93%). There was considerable variation in definition of infection used, as well as considerable risk of bias, particularly as few studies actively screened participants for SSI. Conclusion. Synthesis of published estimates of infection yield a rate higher than that seen in national surveillance procedures. Biases noted in all studies would trend towards an underestimate, largely due to inadequate follow-up


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 81 - 81
1 Mar 2013
de Wilde I Margalet E
Full Access

Methods

A pericapsular approach was used with capsulotomy and then correction of the lesions both in the pelvic and in the femoral aspects. The traction times and total surgery times for the conventional method and the new out-inside technique were compared.

Results

Conventional Hip Arthroscopy

61 Hips done

Total surgery time was 110 minutes

Traction time was 50 minutes

6 Weeks non weight bearing

New out-inside technique of hip arthroscopy

24 Hips done

Total surgery time was 90 minutes

Traction time was 20 minutes

4 weeks non weight bearing

New out-inside technique – E Margalet results

68 Hips done

Total surgery time was 80.5 minutes

Traction time was 18.2 minutes

3-4 weeks non weight bearing


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 883 - 883
1 Sep 1997
Muirhead-Allwood S


Bone & Joint Research
Vol. 9, Issue 12 | Pages 857 - 869
1 Dec 2020
Slullitel PA Coutu D Buttaro MA Beaule PE Grammatopoulos G

As our understanding of hip function and disease improves, it is evident that the acetabular fossa has received little attention, despite it comprising over half of the acetabulum’s surface area and showing the first signs of degeneration. The fossa’s function is expected to be more than augmenting static stability with the ligamentum teres and being a templating landmark in arthroplasty. Indeed, the fossa, which is almost mature at 16 weeks of intrauterine development, plays a key role in hip development, enabling its nutrition through vascularization and synovial fluid, as well as the influx of chondrogenic stem/progenitor cells that build articular cartilage. The pulvinar, a fibrofatty tissue in the fossa, has the same developmental origin as the synovium and articular cartilage and is a biologically active area. Its unique anatomy allows for homogeneous distribution of the axial loads into the joint. It is composed of intra-articular adipose tissue (IAAT), which has adipocytes, fibroblasts, leucocytes, and abundant mast cells, which participate in the inflammatory cascade after an insult to the joint. Hence, the fossa and pulvinar should be considered in decision-making and surgical outcomes in hip preservation surgery, not only for their size, shape, and extent, but also for their biological capacity as a source of cytokines, immune cells, and chondrogenic stem cells. Cite this article: Bone Joint Res 2020;9(12):857–869


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 34 - 34
1 Feb 2015
Lombardi A
Full Access

Not all total hip arthroplasty cases are created equal is a maxim that holds true for both primary and revision scenarios. Complex cases involve patients presenting with compromised bone and/or soft tissue. For primary cases, these include hips with dysplasia, ankylosis, deformed proximal femora, protrusio acetabuli, prior hip fracture with or without failed fixation, previous bony procedures, or neuromuscular conditions. In revision surgery, complex scenarios include cases compromised by bone loss, deterioration of the soft tissues and resulting instability, periprosthetic fracture, leg length discrepancy, infection, and more recently, hypersensitivity reactions. In this interactive session, a moderator and team of experts will discuss strategies for evaluation and management of a variety of challenging hip case scenarios.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 909 - 920
10 Nov 2021
Smith T Clark L Khoury R Man M Hanson S Welsh A Clark A Hopewell S Pfeiffer K Logan P Crotty M Costa M Lamb SE

Aims. This study aims to assess the feasibility of conducting a pragmatic, multicentre randomized controlled trial (RCT) to test the clinical and cost-effectiveness of an informal caregiver training programme to support the recovery of people following hip fracture surgery. Methods. This will be a mixed-methods feasibility RCT, recruiting 60 patients following hip fracture surgery and their informal caregivers. Patients will be randomized to usual NHS care, versus usual NHS care plus a caregiver-patient dyad training programme (HIP HELPER). This programme will comprise of three, one-hour, one-to-one training sessions for the patient and caregiver, delivered by a nurse, physiotherapist, or occupational therapist. Training will be delivered in the hospital setting pre-patient discharge. It will include practical skills for rehabilitation such as: transfers and walking; recovery goal setting and expectations; pacing and stress management techniques; and introduction to the HIP HELPER Caregiver Workbook, which provides information on recovery, exercises, worksheets, and goal-setting plans to facilitate a ‘good’ recovery. After discharge, patients and caregivers will be supported in delivering rehabilitation through three telephone coaching sessions. Data, collected at baseline and four months post-randomization, will include: screening logs, intervention logs, fidelity checklists, quality assurance monitoring visit data, and clinical outcomes assessing quality of life, physical, emotional, adverse events, and resource use outcomes. The acceptability of the study intervention and RCT design will be explored through qualitative methods with 20 participants (patients and informal caregivers) and 12 health professionals. Discussion. A multicentre recruitment approach will provide greater external validity across population characteristics in England. The mixed-methods approach will permit in-depth examination of the intervention and trial design parameters. The findings will inform whether and how a definitive trial may be undertaken to test the effectiveness of this caregiver intervention for patients after hip fracture surgery. Cite this article: Bone Jt Open 2021;2(11):909–920


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 832 - 836
1 Jun 2006
Barker R Takahashi T Toms A Gregson P Kuiper JH

The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture.

Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem.

Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 91 - 91
1 Jul 2014
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 38 - 38
1 May 2014
MacDonald S
Full Access

This session will present a series of challenging and complex primary and revision cases to a panel of internationally respected hip arthroplasty experts. The primary cases will include challenges such as hip dysplasia, altered bony anatomy and fixation challenges. In the revision hip arthroplasty scenarios issues such as bone stock loss, leg length discrepancy, instability and infection will be discussed. This will be an interactive case based session that at its conclusion should leave the attendee with a more thorough approach to these challenging issues.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 42 - 42
1 Aug 2012
Alexander P Ford I Ashcroft G Watson H
Full Access

The reinfusion of perioperative cell salvage is one method employed to reduce exposure to donor blood. Data on the safety of this process, however, are scant. Notably, the effect of intraoperative, washed cell salvage reinfusion on prothrombotic markers has not been demonstrated. The risk of postoperative venous thromboembolism following major orthopaedic operations is not insignificant. The study objective was to assess the effect of cell salvage reinfusion on coagulation and platelet activation.

Twenty-one patients undergoing elective primary hip operations were recruited. Nine patients received washed cell salvage intraoperatively, and were compared with 12 patients undergoing similar surgery that did not. Two patients in the cell salvage group also received postoperative, unwashed cell salvage. Blood samples were collected pre-operatively, immediately post-operatively, and one day post-operatively for assays of platelet activation markers, P-selectin expression and fibrinogen binding by flow cytometry in diluted whole blood; coagulation activation marker, thrombin-antithrombin complex (TAT); D-dimer by ELISA, thrombin generation by chromogenic assay, and full blood count. Samples of cell salvage material were also analysed for prothrombotic markers.

There were no significant differences between the groups preoperatively. Postoperatively haemoglobin levels did not differ significantly between the cell salvage group and controls. Postoperative TAT and D-dimer were significantly higher in the cell salvage group compared with controls (p<0.05). One day postoperatively, there were significantly higher platelet P-selectin expression (p=0.006) and platelet fibrinogen binding (p=0.004) in the cell salvage group compared with controls. The white cell count (WCC) was also significantly higher (p=0.04). In the intraoperative washed cell salvage material, and in postoperative cell salvage, the platelet count was low, but significant proportions of platelets were activated, and levels of D-dimer were elevated compared with venous blood. The postoperative salvage material also contained high levels of TAT.

The results from this pilot study show the induction of a prothrombotic state following reinfusion of intraoperative, washed cell salvage in recipients undergoing primary elective hip operations. An inflammatory response to reinfusion is also indicated by the raised WCC. Further investigation into the safety of cell salvage is indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 937 - 937
1 Sep 1998
Scott G


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 413 - 416
1 Aug 1981
Wicks M Rich G Ratcliff R Hone M

Effective concentrations of antibiotic in the fluid bathing implanted hip prostheses are essential to prevent infection by micro-organisms. Twenty patients undergoing total hip replacement were given one gram of Cephradine intramuscularly one hour before operation and one other received a single bolus of Cephradine intravenously before operation and one other received a single bolus of Cephradine intravenously before operation. The concentrations of antibiotic were greater and persisted longer in the tissue fluid than in the blood. The antibiotic was sufficient to inhibit most micro-organisms causing contamination. We recommend that Cephradine is given intramuscularly one hour before operation and at six-hourly intervals after operation until the drainage tubes and intravenous lines have been removed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 34 - 34
1 May 2013
Lombardi A
Full Access

Not all total hip arthroplasty cases are created equal is a maxim that holds true for both primary and revision scenarios. Complex cases involve patients presenting with compromised bone and/or soft tissue. For primary cases, these include hips with dysplasia, ankylosis, deformed proximal femora, protrusio acetabuli, prior hip fracture with or without failed fixation, previous bony procedures, or neuromuscular conditions. In revision surgery, complex scenarios include cases compromised by bone loss, deterioration of the soft tissues and resulting instability, periprosthetic fracture, leg length discrepancy, infection, and more recently, hypersensitivity reactions. In this interactive session, a moderator and team of experts will discuss strategies for evaluation and management of a variety of challenging hip case scenarios


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 62 - 62
1 Jan 2011
Bennett A Meek R Morrison A
Full Access

Revision total hip replacement is often associated with significant blood loss and subsequent transfusion. Intra-operative cell salvage is one approach to minimising this allogenic transfusion.

We carried out a retrospective study of 158 consecutive revision THRs carried out by one surgeon between June 2003 and September 2006 in the Southern General Hospital, Glasgow.

In the study group (79 patients, operated upon after October 2005) Intra-operative cell salvage was routinely used for all cases. In the control group (79 patients, operated upon before October 2005) Intra-operative cell salvage was not available.

Data was collected on transfusion of salvaged blood, transfusion of allogenic blood, operation type, indication for surgery, complications and length of hospital stay.

Results showed a 53% reduction (p=0.002) in the number of units of allogenic blood transfused in the study group compared with the control group. (1.59 units per case compared with 3.41 units).

In the study group 51% of patients received allogenic blood transfusion, compared with 68% of patients in the control group, a relative reduction of 17% (p=0.02).

There was no difference between the two groups regarding haemoglobin drop and length of hospital stay. Data regarding complications yielded no significant results due to small cohort size.

We conclude that intra-operative cell salvage leads to a significant reduction in allogenic blood transfusion with subsequent implications upon cost, resource management, and patient safety and should be used for all patients undergoing revision hip arthroplasty.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 49 - 49
1 Jun 2017
Bartlett J Lawrence J Khanduja V
Full Access

To quantify the risk posed to the Lateral Femoral Cutaneous Nerve (LFCN) during Total Hip Arthroplasty using the Minimally Invasive Anterior Approach (MIAA), and during placement of the Anterior Portal (AP) in Supine Hip Arthroscopy (SHA).

Forty-five hemipelves from thirty-nine cadavers were dissected. The LFCN was identified proximal to the inguinal ligament (IL), and its path in the thigh identified. The positions of the nerve and its branches in relation to the MIAA incision and the site for AP placement were measured using Vernier Callipers.

44% of nerves crossed the incision line used in the MIAA, at an average distance of 47 ± 28mm from the proximal end of the incision. Of those that did not cross the incision line, the average minimum distance between the nerve and incision was 14.4 ± 7.4mm, occurring on average 74.0 ± 37.3mm from the proximal end of the incision. In addition, the AP was placed in the path of the nerve on 38% of occasions. The nerve took an oblique path, and when found not to intersect with the AP portal, was located 5.7 ± 4.5mm from the portal's edge. We found a reduction in risk if the portal is moved medially or laterally by 15mm from its current location.

The LFCN is at high risk of injury during both THA using the MIAA and SHA using the AP. Our study emphasises the need for meticulous dissection during these procedures, and thorough explanation of these risk whilst consenting patients. We suggest that relocation of the AP 15mm more laterally or medially will reduce the risk posed to the LFCN.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 103 - 107
1 Jan 2000
Pekkarinen J Alho A Lepistö J Ylikoski M Ylinen P Paavilainen T

We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification.

The Mayo hip score improved from a mean of 32 (sd ± 18) to 62 (sd ± 15). Most (25) of the 34 complications occurred in grade-3 and grade-4 defects; nine were intraoperative diaphyseal fractures and eight fractures of the greater trochanter. All the fractures united.

The risk of intraoperative fracture was prevented by supporting the bone with wires in 16 hips, with reinforcement mesh in 18 and by a plate in six. Early migration of the stem of more than 10 mm during the first year indicated rotational instability; it occurred in three cases.

In difficult revision cases with large defects of the femoral bone, bone-impaction techniques carry a high risk of complications.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 551 - 551
1 Aug 2008
Bennett AJ Meek RMD Morrison A
Full Access

Revision total hip replacement is a procedure often associated with significant blood loss and subsequent transfusion. Intra-operative cell salvage is one approach to minimising this problem.

We carried out a retrospective study of 134 consecutive revision total hip carried out by one surgeon between June 2003 and September 2006 in the Southern General Hospital, Glasgow, 134 replacements (excluding those performed in the presence of active infection where cell salvage is contra-indicated).

In Group A (56 patients), operated upon after October 2005, Intra-operative cell salvage was routinely used. In Group B (78 patients), operated upon before October 2005, Intra-operative cell salvage was not used.

Data was collected on transfusion of salvaged blood, transfusion of allogenic blood, operation type, indication for surgery, complications and length of hospital stay.

In Group A, an average of 1.52 units of allogenic blood was transfused per case, compared with an average of 3.35 units in Group B (p=0.01), a reduction of 55%.

In Group A 50% of patients received allogenic blood transfusion, compared with 68% of patients in Group B, a relative reduction of 26% (0.1> p> 0.05).

There was no difference between the two groups regarding haemoglobin drop and length of hospital stay. Data regarding complications yielded no significant results due to small cohort size.

Further Breakdown of data by operation type and indication did not yield significant results due to the small cohort size.

Our results show that routine use of intra-operative cell salvage in revision total hip replacement leads to a significant reduction in allogenic blood transfusion with subsequent implications upon cost, resource management, and patient safety.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1161 - 1167
1 Nov 2001
Owers KL Pyman J Gargan MF Witherow PJ Portinaro NMA

When cerebral palsy involves the entire body pelvic asymmetry indicates that both hips are ‘at risk’. We carried out a six-year retrospective clinical, radiological and functional study of 30 children (60 hips) with severe cerebral palsy involving the entire body to evaluate whether bilateral simultaneous combined soft-tissue and bony surgery of the hip could affect the range of movement, achieve hip symmetry as judged by the windsweep index, improve the radiological indices of hip containment, relieve pain, and improve handling and function.

The early results at a median follow-up of three years showed improvements in abduction and adduction of the hips in flexion, fixed flexion contracture, radiological containment of the hip using both Reimer’s migration percentage and the centre-edge angle of Wiberg, and in relief of pain. Ease of patient handling improved and the satisfaction of the carer with the results was high. There was no difference in outcome between the dystonic and hypertonic groups.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 157 - 157
1 May 2011
Smith T Achaibar K Aduwa E Amlani A Alcena J Bajaj R Soneji N Jagernauth S Murphy J
Full Access

One of the ethical and legal requirements of valid consent for treatment is that patients must be fully informed about the complications involved. The General Medical Council (UK) insists that all adverse outcomes of a treatment, which are serious or frequently occurring, must be discussed with the patient.

Previous studies have found a large variance in the risks documented on consent forms for orthopaedic hip operations. The aim of this study was to compare the risks documented for three orthopaedic hip operations against pre-constructed operation-specific consent forms endorsed by the British Orthopaedic Association.

We retrospectively analysed 300 consent forms for total hip replacements, hip hemiarthoplasties and dynamic hip screw operations (n=100 for each) and noted the risks documented, whether the form was completely legible, the grade of the Doctor obtaining consent and whether a copy of the consent form was given to the patient.

We found that of the 300 operations, only 43.1% of the complications were documented as recommended by the British Orthopaedic Association. Furthermore, 26.3 % of consent forms were illegible, 72.7% of patients were consented by the Senior House Officer and only 13.7% of patients were offered a copy of the consent form.

Our results indicate that the Methods: of obtaining consent and filling in the consent forms for orthopaedic hip operations could be vastly improved. One method which could be utilized to achieve this would be the incorporation of procedure specific templates in the consenting process. These templates are already in the public domain and free to use at www.orthoconsent.com. This would allow the patient to weigh up the risks and make a valid informed decision about their treatment and also protect the Doctors from any possible litigation.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 710 - 720
1 Sep 2021
Kjaervik C Gjertsen J Engeseter LB Stensland E Dybvik E Soereide O

Aims. This study aimed to describe preoperative waiting times for surgery in hip fracture patients in Norway, and analyze factors affecting waiting time and potential negative consequences of prolonged waiting time. Methods. Overall, 37,708 hip fractures in the Norwegian Hip Fracture Register from January 2014 to December 2018 were linked with data in the Norwegian Patient Registry. Hospitals treating hip fractures were characterized according to their hip fracture care. Waiting time (hours from admission to start of surgery), surgery within regular working hours, and surgery on the day of or on the day after admission, i.e. ‘expedited surgery’ were estimated. Results. Mean waiting time was 22.6 hours (SD 20.7); 36,652 patients (97.2%) waited less than three days (< 72 hours), and 27,527 of the patients (73%) were operated within regular working hours (08:00 to 16:00). Expedited surgery was given to 31,675 of patients (84%), and of these, 19,985 (53%) were treated during regular working hours. Patients classified as American Society of Anesthesiologists (ASA) classes 4 and 5 were more likely to have surgery within regular working hours (odds ratio (OR) 1.59; p < 0.001), and less likely to receive expedited surgery than ASA 1 patients (OR 0.29; p < 0.001). Low-volume hospitals treated a larger proportion of patients during regular working hours than high volume hospitals (OR 1.26; p < 0.001). High-volume hospitals had less expedited surgery and significantly longer waiting times than low and intermediate-low volume hospitals. Higher ASA classes and Charlson Comorbidity Index increased waiting time. Patients not receiving expedited surgery had higher 30-day and one-year mortality rates (OR 1.19; p < 0.001) and OR 1.13; p < 0.001), respectively. Conclusion. There is inequality in waiting time for hip fracture treatment in Norway. Variations in waiting time from admission to hip fracture surgery depended on both patient and hospital factors. Not receiving expedited surgery was associated with increased 30-day and one-year mortality rates. Cite this article: Bone Jt Open 2021;2(9):710–720


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 81 - 81
1 Jan 2004
Cutts S Datta A Ayoub K Rhaman H Lawrence T
Full Access

One of the most commonly cited advantages of hip resurfacing is the technical ease of revision surgery on the femoral side of the joint. It is therefore reasonable to suggest that such surgery ought to be associated with reduced operative times, reduced blood loss and more rapid mobilisation than conventional hip revision. However, there is little objective evidence in the literature to support this view.

In our own unit, 6 consultants have now revised 15 hip resurfacings (13 Corins and 2 MMT Birmingham Hip Resurfacings). A retrospective study of the hospital records was performed to compare three well recorded parameters 1) On table operative times 2) Post Operative blood transfusion requirement 3) In patient length of stay.

Average on table time was 195 minutes for conventional THR revision and 120 minutes for revision of resurfacing i.e. a 1 third reduction in theatre time for resurfacing with attendant advantages in costs and risks. However, post operative length of stay was little different between the two groups.

Average blood transfusion requirement was 4.6 units for conventional THR revision (n=190) and 0.9 units for revision of resurfacing. However, these crude figures do not take into account the difference in physiological state between the two groups of patients. A more complex comparison of age matched revision THR patients shows and average transfusion requirement of 1.8 to 2.2 units for revision of THR versus 0.9 units for revision resurfacing.

In conclusion, there is now objective evidence of the advantages of resurfacing in the revision situation but that these advantages are more modest than those anticipated.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 77 - 77
1 Jan 2004
Mellor S Khaleel A Edwards A Gibb P Elliott D Pool R
Full Access

We have reviewed the intermediate term results of 56 out of 61 consecutive Wagner revision stems implanted without bone graft. After a mean of 5 years (range 4 to 7 years) 49 out of 56 hips were graded as excellent or good based on the Harris Hip Score. The clinical result was not related to the degree of femoral bone defect prior to revision.

49 Out of 56 hips were seen to subside, but this did not affect the hip score at final review. The mean subsidence was 4.8mm (range 0 – 19mm).Only one stem showed continued subsidence after 12 months post-operatively, and this stem achieved a stable position by 24 months. All osteotomies of the femur united with reconstitution of the femoral bone stock. There was a low incidence of complications; one stem showed catastrophic subsidence within 48 hours of surgery, requiring re-revision to a larger Wagner stem. There was one sciatic nerve palsy. 3 hips dislocated on one occasion in the early post-operative period, but were stable at latest follow-up.

In conclusion, the Wagner stem can bypass major proximal femoral bony defects and achieve initial axial and rotational stability in intact diaphyseal bone. Subsequent stem subsidence does not affect clinical outcome, and proximal femoral bony reconstitution is achieved without the need for bone grafting.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 104 - 104
1 Feb 2003
Clarke MT Roberts CP Gray J Sule J Keene GS Rushton N
Full Access

Differentiating cases of aseptic loosening of total hip arthroplasty (THA) from loosening due to low-grade infection can often be difficult. It is possible that some cases of ‘aseptic’ loosening may be related to unidentified bacterial infection.

Using Polymerase Chain Reaction (PCR), this study attempted to identify the frequency with which bacterial DNA could be observed at revision arthroplasty for what was considered ‘aseptic’ loosening.

All revision cases had to fulfil strict criteria to be considered aseptically loose In all cases operative specimens from the synovial fluid, synovium, femoral and acetabular membranes where possible were sent for analysis by histology, bacteriology and by PCR to identify the presence of the 16S bacterial ribosomal fraction, an indicator of bacterial DNA. Ten bacteria per millilitre of tissue/fluid were the threshold for detection. As a control for environmental contamination, specimens from primary THA were also sent for analysis in the same manner as revisions.

The identification of bacterial DNA in at least one sample from a patient was considered a positive case result.

45 revision THA were identified over a 3-year period (1998–2001). From those 45 revision cases, 163 specimens were sent for analysis by PCR. These specimens were compared to the control group of 34 primary THA from which 91 specimens were sent for analysis by PCR. When analysed by specimens positive by PCR, bacterial DNA was identified in 55 of 163 specimens sent from the 45 revision THA. This compared with 21 of 91 specimens positive by PCR sent from the 34 primary THA (p=0. 07).

When analysed by cases positive by PCR, bacterial DNA was identified in 29 of 45 revision THA and in 8 of 34 primary THA (p< 0. 001).

PCR is a sensitive test for detecting infection in revision THA. Results from the primary THA cases would suggest there is at least a 23% false positive rate even with negative bacterial culture. The increased frequency with which bacterial DNA has been identified in ‘aseptically’ loose revision THAs, however, is unlikely to be due solely to environmental contamination. These results may have relevance for our interpretation and understanding of aseptic loosening as well for the diagnosis of prosthetic infection.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 23 - 23
1 May 2012
S. B K. R D. B J. O
Full Access

Studies on soil mechanics have established that when vibration is applied to an aggregate, it results in more efficient alignment of particles and reduces the energy required to impact the aggregate. Our aim was to develop a method of applying vibration to the bone impaction process and assess its effect on the mechanical properties of the impacted graft.

Phase 1. Eighty bovine femoral heads were milled using the Noviomagus bone mill. The graft was then washed using a pulsed lavage normal saline system over a sieve tower. A vibration impaction device was developed which housed two 15V DC motors with eccentric weights attached inside a metal cylinder. A weight was dropped onto this from a set height 72 times so as to replicate the bone impaction process. A range of frequencies of vibration were tested, as measured using an accelerometer housed in the vibration chamber. Each shear test was then repeated at four different normal loads so as to generate a family of stress-strain curves. The Mohr-Coulomb failure envelope from which the shear strength and interlocking values are derived was plotted for each test.

Phase 2. Experiments were repeated with the addition of blood so as to replicate a saturated environment as is encountered during operative conditions.

Relatively dry graft impacted with the addition of vibration showed improved shear strength at all frequencies of vibration when compared to impaction without vibration. In our system the optimal frequency of vibration was 60 Hz. Under saturated conditions the addition of vibration is detrimental the shear strength of the aggregate. This is secondary to decreased interlocking between particles and may be explained by the process of liquefaction.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 505 - 505
1 Nov 2011
Mainard D Valentin S Diligent J Choufani É Leyder M Berte N Galois L
Full Access

Purpose of the study: The right position of total hip arthroplasty (THA) implants affects short-, mid- and long-term outcome and complications. Navigation can improve implant position relative to a reference plane, in particular during mini-invasive implantation. The purpose of this work was to compare the position of the prosthetic cup in two series, one implanted with a navigation system and one with the conventional technique.

Material and method: The same surgeon performed the operations in each group of 42 patients (matched for age, gender, BMI, side). In the historic non-navigated series, a press fit femoral implant was used (Excia). The cups were either press fit (Ovalock or Plasmacup), or cemented with polyethylene inserts. The Hardigne incision (15 cm) was used for the conventional implantations. In the prospective navigated series, a press fit femoral element (Excia) and a press fit cup (Plasmacup) were implanted. The Orhtopilot navigation system was used (reference plane: Lewinnek anterior pelvic plane). The adapted Hardinge incision (5 cm) was used for the mini-invasive implantations. Inclination was measured on the weight-bearing pelvis relative to the radiological U line; the Pradhan method was used for anteversion. The objective was to achieve 45° horizontal inclination and 15° anteversion.

Results: In the non-navigated series, the inclination was 53±8 and in the navigated series 44±5.6. On average, inclination decreased significantly (8). Anteversion in the non-navigated series was 7±4, and 12±5.3 in the navigated series. On average, anteversion increased by 6 (statistically significant). The number of cups in the Lewinnek safety zone was 21 of 42 (50%) in the non-navigated series and 38 of 42 (90%) in the navigated series (statistically significant). The increase in leg length was 6.2 mm in the non-navigated group and 4.4 in the navigated group.

Discussion: Positioning did not take into account the preoperative analysis of the hip, but could adapt to scanner or EOS data. Navigation should also integrate offset, femoral position, and leg length.

Conclusion: Navigation of the prosthetic cup improves precision positioning in relation to the reference objectives, in particular, for mini-invasive surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 755 - 759
1 Jun 2011
Brennan SA Brabazon D O’Byrne JM

We developed a method of applying vibration to the impaction bone grafting process and assessed its effect on the mechanical properties of the impacted graft. Washed morsellised bovine femoral heads were impacted into shear test rings. A range of frequencies of vibration was tested, as measured using an accelerometer housed in a vibration chamber. Each shear test was repeated at four different normal loads to generate stress-strain curves. The Mohr-Coulomb failure envelope from which shear strength and interlocking values are derived was plotted for each test. The experiments were repeated with the addition of blood in order to replicate a saturated environment.

Graft impacted with the addition of vibration at all frequencies showed improved shear strength when compared with impaction without vibration, with 60 Hz giving the largest effect. Under saturated conditions the addition of vibration was detrimental to the shear strength of the aggregate. The civil-engineering principles of particulate settlement and interlocking also apply to impaction bone grafting. Although previous studies have shown that vibration may be beneficial in impaction bone grafting on the femoral side, our study suggests that the same is not true in acetabular revision.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 15 - 15
1 May 2015
Lawton R Clift B
Full Access

The posterior approach to the hip avoids violating abductors and has presumed functional advantages. The anterolateral approach risks abductor damage, but has reportedly lower dislocation rate.

To determine effects of surgical approach on function and dislocation after primary and revision THR 3274 primary THRs and 66 first time revision THRs were investigated from the arthroplasty database (2000–2008).

2682 (82%) primary THRs were via anterolateral approach, 592 (18%) by posterior. Post primary dislocation rate was 50/2682 (1.9%) for anterolateral and 26/592 (4.4%) for posterior. Posterior approach had significantly better Harris Hip Scores: 91 vs 88 (P = 0.000) and function: 40 vs 37 (P = 0.000). Of the 66 revisions THRs, 30 were anterolateral and 36 posterior. Dislocation rates were 2/30 (6.7%) and 4/36 (11.1%) respectively. There was no significant difference in Harris Hip Score or Harris Hip Function 1 year after revision based on revision surgery approach. However there was a significant difference in Harris Hip Function 1 year after revision based on the approach for primary surgery (Anterolateral 30 vs Posterior 37, P=0.008) and a similar trend in Harris Hip Score (Anterolateral 79 vs Posterior 85, P = 0.198) and patients who had posterior approach for both primary and revision had the best scores overall.

The clinical relevance of the modest, but statistically significant difference in Harris hip score after primary THR is unclear. That primary approach has an impact on function after revision suggests the posterior approach should be considered in younger patients likely to require revision in the future.