Advertisement for orthosearch.org.uk
Results 1 - 100 of 1269
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 166 - 172
1 Feb 2013
Abolghasemian M Tangsataporn S Sternheim A Backstein D Safir O Gross AE

Trabecular metal (TM) augments are a relatively new option for reconstructing segmental bone loss during acetabular revision. We studied 34 failed hip replacements in 34 patients that were revised between October 2003 and March 2010 using a TM acetabular shell and one or two augments. The mean age of the patients at the time of surgery was 69.3 years (46 to 86) and the mean follow-up was 64.5 months (27 to 107). In all, 18 patients had a minor column defect, 14 had a major column defect, and two were associated with pelvic discontinuity. The hip centre of rotation was restored in 27 patients (79.4%). The Oxford hip score increased from a mean of 15.4 points (6 to 25) before revision to a mean of 37.7 (29 to 47) at the final follow-up. There were three aseptic loosenings of the construct, two of them in the patients with pelvic discontinuity. One septic loosening also occurred in a patient who had previously had an infected hip replacement. The augments remained stable in two of the failed hips. Whenever there was a loose acetabular component in contact with a stable augment, progressive metal debris shedding was evident on the serial radiographs. Complications included another deep infection treated without revision surgery. Good clinical and radiological results can be expected for bone-deficient acetabula treated by a TM cup and augment, but for pelvic discontinuities this might not be a reliable option. Cite this article: Bone Joint J 2013;95-B:166–72


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 312 - 318
1 Apr 2024
Sheth NP Jones SA Sanghavi SA Manktelow A

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity. Cite this article: Bone Joint J 2024;106-B(4):312–318


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 45 - 45
1 Nov 2021
Sugano N Hamada H Takao M Ando W Uemura K Nakamura N
Full Access

The purposes of this study were to evaluate the accuracy and feasibility of a robotic preparation for acetabular metal augments in patients with developmental dysplasia of the hip (DDH). Mako robotic arm reaming was used in 7 DDH to prepare the bony cavities for both Trident PSL cups and Tritanium acetabular wedge augments in six hips with Crowe 2 or 3 DDH. In CT-based planning, a properly sized cup was placed in the original acetabulum, and the same sized cup was also placed to fit the superolateral acetabular defect. The coordinates of the planned positions of cup and augment were recorded to manage the robotic arm reaming. After registration of the patient's pelvis, robotic reaming was performed first for the augment, then, for the cup by changing the target position of reaming as planned. The accuracy of the cup and augment placement was assessed on postoperative CT. To evaluate the feasibility of the robotic procedure, the OR time and blood loss were compared with those of 13 patients who received the same cup and augment systems with a conventional technique. All procedures were done without fracture or fixation failure. There were no differences in OR time or blood loss between the two procedures. Postoperative CT measurements of the distance between the cup center and the augment sphere center showed less than 2mm difference from the Mako preoperative planning. Although a longer time of follow up evaluation is mandatory, our robotic acetabular augment preparation technique is accurate and feasible


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 54 - 58
1 May 2024
Wassilew GI Zimmerer A Fischer M Nonnenmacher L O'Hara L Hube R

Aims. The use of a porous metal shell supported by two augments with the ‘footing’ technique is one solution to manage Paprosky IIIB acetabular defects in revision total hip arthroplasty. The aim of this study was to assess the medium-term implant survival and radiological and clinical outcomes of this technique. Methods. We undertook a retrospective, two-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the ‘footing’ technique for Paprosky IIIB acetabular defects between 2007 and 2020. The median age at the time of surgery was 64.4 years (interquartile range (IQR) 54.4 to 71.0). The median follow-up was 3.9 years (IQR 3.1 to 7.0). Results. The cumulative medium-term survival of the acetabular construct was 89%. Two hips (5.1%) required further revision due to shell loosening, one hip (2.6%) due to shell dislocation, and one hip (2.6%) due to infection. The median Harris Hip Score improved significantly from 47 points (IQR 41.5 to 54.9) preoperatively to 80 points (IQR 73.5 to 88.6) at the latest follow-up (p < 0.001). Conclusion. The reconstruction of Paprosky IIIB acetabular defects with porous tantalum shells and two augments using the ‘footing’ technique showed excellent medium-term results. It is a viable option for treating these challenging defects. Cite this article: Bone Joint J 2024;106-B(5 Supple B):54–58


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 106 - 106
1 Jul 2020
Dion C Lanting B Howard J Teeter M Willing R
Full Access

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) were potted in custom fixtures. Primary total knee arthroplasty (pTKA) surgery was performed on all tibias. Fixation stability testing was conducted using a three-stage eccentric loading protocol. Static eccentric (70% medial/ 30% lateral) loading of 2100 N was applied to the implants before and after subjecting them to 5×103 loading cycles of 700 N at 2 Hz using a joint motion simulator. Bone-implant micromotion was measured using a high-resolution optical system. The pTKA were removed. The proximal tibial bone defect was measured. One tibia from each pair was randomly allocated to the experimental group, and rTKA was performed with a titanium augment printed using selective laser melting. The contralateral side was assigned to the control group (revision with fully cemented stems). The three-stage eccentric loading protocol was used to test the revision TKAs. Independent t-tests were used to compare the micromotion between the two groups. After revision TKA, the mean micromotion was 23.1μm ± 26.2μm in the control group and 12.9μm ± 22.2μm in the experimental group. There was significantly less micromotion in the experimental group (p= 0.04). Prior to revision surgery, the control and experimental group had no significant difference in primary TKA micromotion (p= 0.19) and tibial bone loss (p= 0.37). This study suggests that early fixation stability of revision TKA with the novel 3D printed titanium augment is significantly better then the conventional fully cemented rTKA. The early press-fit fixation of the augment is likely sufficient for promoting bony ingrowth of the augment in vivo. Further studies are needed to investigate the long-term in-vivo fixation of the novel 3D printed augment


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 903 - 908
1 Jul 2018
Eachempati KK Malhotra R Pichai S Reddy AVG Podhili Subramani AK Gautam D Bollavaram VR Sheth NP

Aims. The advent of trabecular metal (TM) augments has revolutionized the management of severe bone defects during acetabular reconstruction. The purpose of this study was to evaluate patients undergoing revision total hip arthroplasty (THA) with the use of TM augments for reconstruction of Paprosky IIIA and IIIB defects. Patients and Methods. A retrospective study was conducted at four centres between August 2008 and January 2015. Patients treated with TM augments and TM shell for a Paprosky grade IIIA or IIIB defect, in the absence of pelvic discontinuity, and who underwent revision hip arthroplasty with the use of TM augments were included in the study. A total of 41 patients with minimum follow-up of two years were included and evaluated using intention-to-treat analysis. Results. There were 36 (87.8%) patients with a Paprosky IIIA defect and five (12.2%) patients with a Paprosky IIIB defect. The mean age was 56.7 years (28 to 94). There were 21 (51.2%) women and 20 (48.8%) men. The mean follow-up was 39.4 months (12 to 96). One (2%) patient died after eight years. No failures were noted in the series. The mean survivorship was 100% at the time of latest follow-up. Conclusion. The results of this multicentre study showed encouraging short- and mid-term results for the use of TM augments in the management of Paprosky grade IIIA and IIIB defects. Cite this article: Bone Joint J 2018;100-B:903–8


Bone & Joint Research
Vol. 7, Issue 4 | Pages 282 - 288
1 Apr 2018
Beckmann NA Bitsch RG Gondan M Schonhoff M Jaeger S

Objectives. In order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined. Methods. A total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm augment. Each acetabular component and augment was affixed to the bone using two screws, while the method of fixation between the acetabular component and augment varied for the three groups of six hemipelvises: group S, screw fixation only; group SC, screw plus cement fixation; group C, cement fixation only. The implanted hemipelvises were cyclically loaded to three different loading maxima (0.5 kN, 0.9 kN, and 1.8 kN). Results. Screw fixation alone resulted in up to three times more movement (p = 0.006), especially when load was increased to 100% (p < 0.001), than with the other two fixation methods (C and SC). No significant difference was noted when a screw was added to the cement fixation. Increased load resulted in increased relative movement between the interfaces in all fixation methods (p < 0.001). Conclusion. Cement fixation between a porous titanium acetabular component and augment is associated with less relative movement than screw fixation alone for all implant interfaces, particularly with increasing loads. Adding a screw to the cement fixation did not offer any significant advantage. These results also show that the stability of the tested acetabular component/augment interface affects the stability of the construct that is affixed to the bone. Cite this article: N. A. Beckmann, R. G. Bitsch, M. Gondan, M. Schonhoff, S. Jaeger. Comparison of the stability of three fixation techniques between porous metal acetabular components and augments. Bone Joint Res 2018;7:282–288. DOI: 10.1302/2046-3758.74.BJR-2017-0198.R1


Bone & Joint Research
Vol. 13, Issue 6 | Pages 279 - 293
7 Jun 2024
Morris JL Letson HL McEwen PC Dobson GP

Aims. Adenosine, lidocaine, and Mg. 2+. (ALM) therapy exerts differential immuno-inflammatory responses in males and females early after anterior cruciate ligament (ACL) reconstruction (ACLR). Our aim was to investigate sex-specific effects of ALM therapy on joint tissue repair and recovery 28 days after surgery. Methods. Male (n = 21) and female (n = 21) adult Sprague-Dawley rats were randomly divided into ALM or Saline control treatment groups. Three days after ACL rupture, animals underwent ACLR. An ALM or saline intravenous infusion was commenced prior to skin incision, and continued for one hour. An intra-articular bolus of ALM or saline was also administered prior to skin closure. Animals were monitored to 28 days, and joint function, pain, inflammatory markers, histopathology, and tissue repair markers were assessed. Results. Despite comparable knee function, ALM-treated males had reduced systemic inflammation, synovial fluid angiogenic and pro-inflammatory mediators, synovitis, and fat pad fibrotic changes, compared to controls. Within the ACL graft, ALM-treated males had increased expression of tissue repair markers, decreased inflammation, increased collagen organization, and improved graft-bone healing. In contrast to males, females had no evidence of persistent systemic inflammation. Compared to controls, ALM-treated females had improved knee extension, gait biomechanics, and elevated synovial macrophage inflammatory protein-1 alpha (MIP-1α). Within the ACL graft, ALM-treated females had decreased inflammation, increased collagen organization, and improved graft-bone healing. In articular cartilage of ALM-treated animals, matrix metalloproteinase (MMP)-13 expression was blunted in males, while in females repair markers were increased. Conclusion. At 28 days, ALM therapy reduces inflammation, augments tissue repair patterns, and improves joint function in a sex-specific manner. The study supports transition to human safety trials. Cite this article: Bone Joint Res 2024;13(6):279–293


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 311 - 316
1 Mar 2019
Löchel J Janz V Hipfl C Perka C Wassilew GI

Aims. The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. Patients and Methods. Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity. Results. The overall survival of the acetabular component at a mean of ten years postoperatively was 92.5%. Three hips (5.6%) required further revision due to aseptic loosening, and one (1.9%) required revision for infection. Three hips with aseptic loosening failed, due to insufficient screw fixation of the shell in two and pelvic discontinuity in one. The mean Harris Hip Score improved significantly from 55 (35 to 68) preoperatively to 81 points (68 to 99) at the latest follow-up (p < 0.001). Conclusion. The reconstruction of acetabular defects with TM shells and augments showed excellent long-term results. Supplementary screw fixation of the shell should be performed in every patient. Alternative techniques should be considered to address pelvic disconinuity. Cite this article: Bone Joint J 2019;101-B:311–316


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 84 - 84
1 Mar 2017
Pianigiani S Vignoni D Innocenti B
Full Access

Introduction. In revision TKA, the management of bone loss depends on location, type, and extent of bony deficiency. Treatment strategies involve cement filling, bone grafting and augments. On the market several solutions are currently available, differing for their shape, thickness and material. While the choice of the shape and the thickness is mainly dictated by the bone defect, no explicit guideline is currently available to describe the best choice of material to be selected for a specific clinical situation. However, the use of different materials could induce different response in term of bone stress and thus changes in implant stability that could worsen long-term implant performance. For these reasons, an investigation about the changes in bone stress in the femur and in the tibia when augments, with different materials and thicknesses was performed. Methods. Different configurations have been separately considered including proximal tibial, distal or/and posterior femoral augments with a thickness of 5, 10 and 15 mm. Apart the control, in which no augments were used, but only the TKA is considered, the augment in all the other configurations were considered made by three different materials: bone cement, to simulate cement filling, tantalum trabecular metal and conventional metal (titanium for the tibia and CoCr for the femoral augments). Each configuration was inserted on a lower leg model including a cruciate-retaining total knee arthroplasty and analyzed by means of finite element analysis applying the max force achieved during walking. The bone stress was investigated in the medial and lateral region of interest close to the augment (with a bone thickness of 10 mm) and in an additional bone region of interest of 50 mm thickness. The bone stress have been compared among the different models and also with respect to the control model. Results. In general, the use of an augment induces a change in bone stress, especially in the region close to the bone cuts. The stiffness of the augment must be as close as possible to the one of the bone. Cement has the best results in terms of bone stress, however, it is only suitable for extremely small defects. Tantalum trabecular metal has results very close to cement and it could be consider a good alternative to cement for any size of defect. Metal (both titanium and CoCr) has the least satisfying results inducing the highest change in bone stress with respect the control. Conclusions. Tibial and femoral bone augments are adopted in case of bone defects that could be present during a revision knee replacement. Several solutions are available on the market in different shapes and materials. However, very few studies are reported to provide possible guidelines. The results of this study demonstrate that material stiffness of the augment must be as close as possible to the one of the bone to achieve the best results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 515 - 515
1 Dec 2013
Sabesan V Callanan M Sharma V
Full Access

Background. Total shoulder arthroplasty is technically demanding in regards to implantation of the glenoid component, especially in the setting of increased glenoid deformity and posterior glenoid wear. Augmented glenoid implants are an important and innovative option; however, there is little evidence accessible to surgeons to guide in the selection of the appropriate size augmented glenoid. Methods. Solid computer models of a commercially available augmented glenoid components (+3, +5, +7) contained within the software allowed for placement of the best fit glenoid component within the 3D reconstruct of each patient's scapula. Peg perforation, amount of bone reamed and amount of medialization were recorded for each augment size. Results. There was strong correlation between the medialization of the joint line and the glenoid retroversion for each augmented component (R. 2. of 0.785 for the +3 augment, an R. 2. of 0.792 for the +5 component, and an R. 2. of 0.701 for the +7 component). The range of retroversion that restored anatomic joint line using the +3 augmented glenoid was −3° to −17°, −5° to −24° using the +5 augmented glenoid, and −9° to −31° for a +7 augmented glenoid. Conclusions. Our results provide a general guideline for clinicians to select an appropriate sized augmented glenoid implant based on range of glenoid retroversion that can be corrected to restore the native joint line and minimize peg perforation. There was a strong correlation between glenoid retroversion and medialization for all augment sizes supporting the recommendation for glenoid retroversion as the primary guide in selecting the amount of augmentation


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 103 - 108
1 Nov 2013
Abolghasemian M Tangsataporn S Sternheim A Backstein DJ Safir OA Gross AE

The conventional method for reconstructing acetabular bone loss at revision surgery includes using structural bone allograft. The disadvantages of this technique promoted the advent of metallic but biocompatible porous implants to fill bone defects enhancing initial and long-term stability of the acetabular component. This paper presents the indications, surgical technique and the outcome of using porous metal acetabular augments for reconstructing acetabular defects. . Cite this article: Bone Joint J 2013;95-B, Supple A:103–8


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 607 - 613
1 May 2017
Mäkinen TJ Abolghasemian M Watts E Fichman SG Kuzyk P Safir OA Gross AE

Aims. It may not be possible to undertake revision total hip arthroplasty (THA) in the presence of massive loss of acetabular bone stock using standard cementless hemispherical acetabular components and metal augments, as satisfactory stability cannot always be achieved. We aimed to study the outcome using a reconstruction cage and a porous metal augment in these patients. Patients and Methods. A total of 22 acetabular revisions in 19 patients were performed using a combination of a reconstruction cage and porous metal augments. The augments were used in place of structural allografts. The mean age of the patients at the time of surgery was 70 years (27 to 85) and the mean follow-up was 39 months (27 to 58). The mean number of previous THAs was 1.9 (1 to 3). All patients had segmental defects involving more than 50% of the acetabulum and seven hips had an associated pelvic discontinuity. . Results. Three failures were observed in two hips, both of which had undergone a previous resection of a tumour affecting the acetabulum. Other complications included a late arterial injury, a sciatic nerve palsy, a dislocation treated with a femoral revision, a deep infection treated with irrigation and debridement and a fracture of the greater trochanter treated conservatively. The mean Oxford Hip Score significantly increased from 13.9 (2 to 23) to 28.7 (13 to 38) (p < 0.00001). The mean vertical distance between the centre of rotation of the hip and its normal location decreased from 30 mm to 10 mm. Conclusions. Acceptable early survivorship can be achieved using this novel technique, but it may be unsuitable for use in patients who have previously undergone the resection of a tumour involving the acetabulum. Cite this article: Bone Joint J 2017;99-B:607–13


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 68 - 68
1 Nov 2015
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating pre-operative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Large prosthetic augments (cones); 7) Massive structural allograft-prosthetic composites (APC); 8) Custom implants. Maximizing support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Pre-operative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the pre-operative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intra-operative findings such as occult fracture through deficient periprosthetic bone. Reconstruction of bone deficiency following removal of the failed implant is largely dictated by the location and extent of bone loss and the quality of bone that remains. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions the degree of implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects especially of the cavitary sort may be well managed with minimal constraint


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 115 - 115
1 Feb 2015
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating preoperative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Large prosthetic augments (cones); 7) Massive structural allograft-prosthetic composites (APC); 8) Custom implants. Maximising support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Preoperative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the preoperative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intraoperative findings such as occult fracture through deficient periprosthetic bone. Reconstruction of bone deficiency following removal of the failed implant is largely dictated by the location and extent of bone loss and the quality of bone that remains. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions the degree of implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects especially of the cavitary sort may be well managed with minimal constraint


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 108 - 108
1 May 2014
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty. Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating preoperative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System. This system provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are as follows: 1) fill with cement, 2) fill with cement supplemented by screws or K-wires, 3) Morsellised bone grafting (for smaller, especially contained cavitary defects), 4) Small segment structural bone graft, 5) Impaction grafting, 6) Large prosthetic augments (cones), 7) Massive structural allograft-prosthetic composites (APC), 8) Custom implants. It is very helpful for revision surgeons to have a variety of reconstructive options available, even despite a well thought-out preoperative plan. Preoperative planning is important but the plan that results may require alteration during the course of the surgery to accommodate bone defects which are either less or more severe than thought pre-operatively, and to adjust to variable quality and extent of host bone remaining, as this provides the mechanical platform for the reconstruction. Maximising support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Bone defect management during revision total knee arthroplasty can provide a wide range of challenges from relatively trivial problems with small defects manageable with cement or small amounts of cancellous graft to massive deficiencies that may defy reconstruction except with allograft prosthetic components or large segmental replacing tumor-type implants. The more common Type II deficiencies increasingly seen in the context of particulate driven osteolysis demand a wide range of implant and bone graft options so that an individualised reconstruction can be accomplished for that particular patient based on bone defect size, location, quality of bone remaining, ligamentous status, and anticipated patient demands


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 109 - 109
1 May 2013
Barrack R
Full Access

The major causes of revision total knee are associated with some degree of bone loss. The missing bone must be accounted for to insure success of the revision procedure, to achieve flexion extension balance, restore the joint line to within a centimeter of its previous level, and to assure a proper sizing especially the anteroposterior diameter of the femoral component. In recent years, clinical practice has evolved over time with a general move away from a structural graft with an increase in utilisation of metal augments. Alternatives include cement with or without screw fixation, rarely, with the most common option being the use of metal wedges. With the recent availability of highly porous augments, the role of metal augmentation has increased. Bone graft is now predominantly used in particulate form for contained defects with more limited use of structural graft. The role of the allograft-prosthetic composite has become more limited. For the elderly with osteopenia and massive bone loss, complete metal substitution with an oncology prosthesis has become more common. The degree of bone loss is a major determinant of the management strategy. For contained defects less than 5 mm, cement alone, with or without screw supplementation, may be adequate. For greater than 5 mm, morselised graft is frequently used. For uncontained defects of up to 15 mm or more, metal augmentation is the first choice. Bone graft techniques can be utilised in this setting, however, these are more time consuming and technically demanding with little demonstrated advantage. For larger, uncontained defects, newer generation highly porous augments and step wedges are useful. Large contained defects can be dealt with utilising impaction grafting, similar to the hip impaction grafting technique. Massive distal defects are expeditiously managed with oncology defects in the case of periprosthetic fracture and/or massive osteolysis particularly when combined with osteopenia in an elderly, low demand patient. Surgeons must be familiar with an array of techniques in order to effectively deal with the wide spectrum of bone defects encountered during revision total knee arthroplasty


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims. Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes. Patients and Methods. A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method. Results. The median follow-up was 92 months (4 to 288). The mean MSTS 87 score was 29.1 (19 to 35), the mean MSTS 93 score was 82.2 (50 to 100) and the mean TESS score was 81.2 (43 to 100). Overall survival of the allograft was 84.8%. A total of 15 patients (33%) had a complication. Five allografts were revised for complications and one for local recurrence. Conclusion. Intercalary allografts augmented with intramedullary cement and compression plate fixation provide a reliable and durable method of reconstruction after the excision of a primary diaphyseal bone tumour, with high levels of function and satisfaction. . Cite this article: Bone Joint J 2017;99-B:973–8


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1183 - 1189
1 Sep 2017
Cho BK Kim YM Choi SM Park HW SooHoo NF

Aims. The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure. Patients and Methods. A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs. Results. The mean FAOS and FAAM scores improved significantly to 87.5 (73 to 94) and 85.1 (70 to 95) points at final follow-up, respectively (p < 0.001). The mean angle of talar tilt and anterior talar translation improved significantly to 2.8° (0° to 6°) and 4.1 mm (2 to 7) at final follow-up, respectively (p < 0.001). Side to side comparison in stress radiographs at final follow-up showed no significant difference. The revision failed in one patient who underwent a further revision using allograft tendon. Conclusion. The revision modified Broström procedure augmented with suture tape is an effective form of treatment for recurrent instability of the ankle following a failed Broström procedure. This technique provides reliable stability and satisfactory clinical outcomes at intermediate-term follow-up. Cite this article: Bone Joint J 2017;99-B:1183–9


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 195 - 199
1 Mar 2004
Patel JV Masonis JL Guerin J Bourne RB Rorabeck CH

We report the five- to-ten year results of Anderson Orthopaedic Research Institute type-2 bone defects treated with modular metal augments in revision knee surgery. A total of 102 revision knee arthroplasties in patients with type-2 defects treated with augments and stems were prospectively studied. Seven patients (seven knees) had incomplete follow-up and 15 patients (16 knees) died with the arthroplasty in situ. The mean follow-up of the 79 remaining knees was 7 ± 2 years (5 to 11). The presence of non-progressive radiolucent lines around the augment in 14% of knees was not associated with poorer knee scores, the range of movement, survival of the component or the type of insert which was used (p > 0.05). The survival of the components was 92 ± 0.03% at 11 years (95% CI, 10.3 to 11.2). We recommend the use of modular augmentation devices to treat type-2 defects in revision knee surgery


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 363 - 363
1 May 2009
Panchbhavi V Vallurupalli S Morris R Patterson R
Full Access

Introduction: Screws placed in the fibula do not have a satisfactory purchase during internal fixation of an osteoporotic ankle fracture. Tibia-pro-fibula screws that extend from the fibula into the distal tibial metaphysis provide additional purchase. The purpose of this study is to investigate if purchase of these screws can be enhanced further by injecting calcium sulfate and calcium phosphate composite graft in the drill holes prior to insertion of the screws. Methods: Bone density was quantified using DEXA scan in paired cadaver legs. One leg from each pair was randomly selected for injection of composite graft into screw holes before insertion of the screws. Two screws were inserted through the fibula into the distal tibial metaphysis in each leg, at the level of the syndesmosis under fluoroscopy in a standardized fashion using a jig. The screws were pulled out using a materials testing machine. Stiffness, force, displacement, and energy required were recorded. Results: After testing 4 pairs of cadaver legs, a statistically significant difference was noted in displacement, failure load, and failure energy between augmented and non-augmented screws, with the augmented screws being considerably stronger. Of the two screws the distal, when compared to the proximal one, required more displacement, higher force and energy to fail whether augmented with composite graft or not. Conclusion: Screws augmented with composite graft provide significantly greater purchase in an osteoporotic distal tibial metaphysis than non-augmented screws. Clinical relevance: Use of composite graft to augment purchase of the screws inserted in the distal tibial metaphysis may enhance the stability of the internal fixation of an osteoporotic ankle fracture. This will enable early weight-bearing mobilization and return to function which is important in elderly patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 22 - 22
1 Aug 2012
Coathup M Lo W Edwards T Blunn G
Full Access

Introduction. This study investigated the binding agent Calcium/Sodium Alginate fibre gel and the addition of autogenic bone marrow aspirate (BMA) on bone growth into a porous HA scaffold implanted in an ovine femoral condyle critical-sized defect. Our hypothesis was that Alginate fibre gel would have no negative effect on bone formation and osteoconduction within the scaffold and that BMA would augment the incorporation of the graft with the surrounding bone at 6 and 12 weeks post implantation. Methods. 24, 8mm x 15mm defects were filled with either porous HA granules, porous HA granules + Alginate fibre gel (HA putty) or porous HA granules + Alginate fibre gel + BMA (HA putty +BMA) and remained in vivo for 6 and 12 weeks (n=4). 1ml of bone marrow aspirate per cm3 of graft was used. Image analysis quantified bone apposition rates, bone ingrowth, bone-implant contact and quantity of graft. Mann Whitney U tests were used for statistical analysis where p<0.05 was considered significant. Results. Highest bone formation were measured in the 12 week HA putty+BMA group (1.57±0.24(micromillimetres/day). HA granules at 12 weeks encouraged the greatest increase in bone formation (33.56±3.53%). Smaller amounts of bone was measured in the 6 week HA putty+BMA group (8.57±2.86%). Bone formation in the HA group at 12 weeks was significantly higher when compared with the HA putty (p= 0.043) and the HA putty+BMA group (p= 0.043). At both the 6 and 12 week time point, highest bone-implant contact was seen in the HA granules group (59.34±10.89% and 72.65±3.38% respectively) when compared with both the HA putty (p=0.018) and HA putty+BMA (p=0.047). Results showed no significant difference in the amount of implant remaining when each group was compared. Conclusions. Results from this study showed that the inclusion of BMA did not augment bone growth to the scaffold or increase its osteoconductive capacity when combined with Calcium/Sodium Alginate fibre gel. Further research is necessary to optimise Calcium/Sodium Alginate fibre gel when used to bind HA granules and to investigate the effect of BMA with this type of HA alone


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 66 - 66
1 Jul 2014
Abdel M
Full Access

Massive bone loss on both the femur and tibia during revision total knee arthroplasty (TKA) remains a challenging problem. Multiple solutions have been proposed for small osseous defects, including morselised cancellous bone grafting, small-fragment structural allograft, thicker polyethylene inserts, and the use of modular augments attached to revision prosthetic designs. Large osseous defects can be treated with structural allografts, impaction bone-grafting with or without mesh augmentation, custom prosthetic components, and specialised hinged knee components. The metaphyseal area of the distal femur and proximal tibia is a particularly attractive option during revision TKA given that it is usually undamaged and well-vascularised. While multiple reconstructive options have been recommended, porous tantalum metaphyseal cones have the advantage of improved biologic fixation because of their high porosity (75–80%), interconnected pore space, and low modulus of elasticity (3 MPa) similar to that of cancellous bone. Such features allow tantalum cones to fill bone defects while tolerating physiological loads. Indications for porous tantalum metaphyseal cones include patients with Anderson Orthopaedic Research Institute Type 2B or greater defects. The surgical technique is simpler than structural allograft reconstructions with decreased preparation time, resulting in a possible decrease in infection rates. The modularity of porous tantalum metaphyseal cones also allows the surgeon to choose a size and position that best fits the individual defect encountered. Moreover, tantalum cones can be used with several revision systems. Short-term clinical follow up indicates that porous tantalum metaphyseal cones effectively provide structural support with the potential for long-term biologic fixation and durable reconstructions


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 48 - 48
1 Dec 2014
Maqungo S North D Nortje M Bernstein B
Full Access

Purpose:. To examine the performance of a novel blood plasma-based bone putty for augmenting the treatment of open tibia fractures. The putty was manufactured from pooled blood plasma and contains a concentration of both plasma and platelet-derived regenerative factors. Based on clinical reports of the use of autologous platelet-rich plasma to treat injuries, we hypothesized that the putty would accelerate healing of fractures and surrounding soft tissues. Methods:. Two-arm, randomized controlled study including 20 treatment patients and 10 controls. Follow-up examinations occurred at 14, 30, 60, 90, 180, and 365 days. The product was provided in a syringe containing 3 cc of putty in a double-pouched, sterile box. The putty was placed at the fracture site during open fracture reduction and mechanical stabilization. Results:. Both treatment and control groups were well balanced with a mean age of 35. Seventy percent were Gustillo IIIA and IIIB injuries, 67% were active smokers, and 70% received external fixation. No adverse events related to the use of the putty were noted. The use of the putty significantly reduced infections at 90 days (p = 0.002), accelerated bone bridging at 90 and 180 days, and provided more rapid wound closure at 30 days. In the subset of patients with IIIA/IIIB injuries, the putty group demonstrated more significantly reduced infections (p = 0.0007), with accelerated bone healing and wound closure approaching statistical significance. There were statistically fewer adverse events with the putty (42.1%) compared to controls (80.0%). Conclusions:. The potential for using a concentration of natural plasma and platelet-derived regenerative factors to augment the healing of traumatic injuries makes this first-in-man study relevant and exciting. The putty performed as expected, promoting more rapid healing of both fractures and wounds. The dramatic reduction in infections was unanticipated and is likely related to antimicrobial peptides in plasma and platelets


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 179 - 185
1 Jan 2010
Väänänen P Pajamäki I Paakkala A Nurmi JT Pajamäki J

We used a biodegradable mesh to convert an acetabular defect into a contained defect in six patients at total hip replacement. Their mean age was 61 years (46 to 69). The mean follow-up was 32 months (19 to 50). Before clinical use, the strength retention and hydrolytic in vitro degradation properties of the implants were studied in the laboratory over a two-year period. A successful clinical outcome was determined by the radiological findings and the Harris hip score. All the patients had a satisfactory outcome and no mechanical failures or other complications were observed. No protrusion of any of the impacted grafts was observed beyond the mesh. According to our preliminary laboratory and clinical results the biodegradable mesh is suitable for augmenting uncontained acetabular defects in which the primary stability of the implanted acetabular component is provided by the host bone. In the case of defects of the acetabular floor this new application provides a safe method of preventing graft material from protruding excessively into the pelvis and the mesh seems to tolerate bone-impaction grafting in selected patients with primary and revision total hip replacement


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 128 - 129
1 May 2011
Grappiolo G Cattaneo G Traverso F Della Rocca F
Full Access

Introduction: Acetabular bone defects are critical and frustrating issue; indeed is possible to obtain good reconstruction with conventional Methods: (i.e. bulk graft, cage and cement) but good results are limited to short and mid term. Aim of this paper is to present reconstructive method based on filling the defect with an augment made of tantalum (augmentation technique). Methods: We analized 42 cases from February 2005 to March 2009 with an average age of 63 years old with acetabular defect, scored 3A or more (4 patients had pelvic disjunction) according Paprosky classification. The average age was very low, with 12 cases under 60 years (28,57%) and 21 under 70 (50%). 18 patients were re-revision (at time of surgery were at third or fourth surgical procedure) representing 54,2% of cases. Complete clinical, radiographic evaluation and survivorship analysis for the entire study cohort was performed from an average follow up of 26 months (min 6–max 55 months). Results and Discussion: Preliminar results are encouraging: in only two case we had poor results with step pain and prescribed partial load and walking with two crutches, slight radiographic sign of migration where present at the last follow-up. These patients were previously submitted to many surgical procedures with significant bone loss, soft tissue damages and both with history of previous infection, classified as pelvic disjunction. One of these reported a ischiatic palsy. In the remaining cases we obtained good functional recover, no failures at two years average of follow-up. 40 patients didn’t show hip or groin pain during stance position or walking, no bone resorption or implant mobilization were seen at radiographic follow-up. The HHS increases from 23,04 pre op to 85,15 post op. In no case were found clinical, radiographic, or biochemical signs of infection. According with literature the rationale of augmentation technique with trabecular metal should give long lasting favourable results for its excellent bone ingrowth and mechanical properties. Our results almost match the results of other authors. These brilliant results, partially due to osteoconductive proprieties of tantalum (despite we require time to confirmate), are certainly obtained thank to the optimal centre of rotation reconstruction, always close the physiological one


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1150 - 1156
1 Aug 2005
Hayashi K Fotovati A Ali SA Oda K Oida H Naito M

The reduced stability of hydroxyapatite (HA)-coated implants in osteopenic conditions is considered to be a major problem. We therefore developed a model of a boosted cementless implantation in osteopenic rats. Twelve-week-old rats were either ovariectomised (OVX) or sham-operated (SO), and after 24 weeks plain or HA-coated implants were inserted. They were treated with either a prostaglandin EP4 receptor agonist (ONO-4819) or saline for one month. The EP4 agonist considerably improved the osteoporosis in the OVX group. Ultrastructural analysis and mechanical testing showed an improvement in the implant-bone attachment in the HA-coated implants, which was further enhanced by the EP4 agonist. Although the stability of the HA-coated implants in the saline-treated OVX rats was less than in the SO normal rats, the administration of the EP4 agonist significantly compensated for this shortage. Our results showed that the osteogenic effect of the EP4 agonist augmented the osteoconductivity of HA and significantly improved the stability of the implant-bone attachment in the osteoporotic rat model


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 175 - 175
1 Jan 2013
Demol J Lenaerts B Leuridan S Delport H
Full Access

Introduction. Surgeons are often confronted with large amounts of bone loss during the revision of total hip prostheses. Regularly, porous metals are applied to reconstruct the missing bone. Rapid and extensive bone infiltration into the implant's pores is essential to obtain strong and durable biological fixation. Today, specialised layered manufacturing techniques provide the flexibility to produce custom-made metallic implants with a personalized external shape and a well-controlled internal network of interconnected pores. In this study, bone ingrowth in porous titanium structures that were manufactured by selective laser melting (SLM) was evaluated in an in vivo goat model. Methods. Cylindrical Ti6Al4V constructs (Ø8mm × 14mm, porosity 75%) with or without hydroxyapatite coating were implanted in six Saanen goats. Three holes were drilled in the subchondral bone of each tibia and femur. Constructs were inserted into the holes in a press-fit manner. Resonance frequency analysis was used to measure construct stability. At 3, 6 and 9 weeks after surgery, fluorochrome labels were injected. After 6 and 12 weeks, samples were explanted. Some samples were scanned with micro-CT and subsequently sectioned for histological analysis. The others were used for pull-out tests. Results. Resonance frequency analysis indicated a noticeable increase in implant stability. Evaluation of micro-CT and histological data showed bone ingrowth for all goats at 6 and 12 weeks. Most bone ingrowth occurred during the first 6 weeks, which was followed by a slight increase between week 6 and 12. Fluorochrome labeling confirmed these results. Pull-out tests showed an increased fixation at the bone-implant interface. Conclusion. Porous titanium structures manufactured by SLM have good osseointegration characteristics. As custom-made bone augments, they provide a promising approach to the reconstruction of severe bone defects


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 418 - 422
1 May 1990
Nicholas R Orr J Mollan R Calderwood J Nixon Watson P

Augmentation of the acetabular component of total hip replacements is a method of increasing stability and preventing recurrent dislocation. We report a series of mechanical experiments designed to evaluate the turning moments and angles required to dislocate standard, long posterior wall and two different augmented prostheses


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 17 - 17
1 May 2015
Mathews J Whitehouse M Baker R
Full Access

Cement-induced thermal osteonecrosis is well documented, as is the potential for nerve injury from thermal energy. Cement is often used to augment fixation following excision of humeral metastases. Porcine femurs were used as a model. We sought to find out the maximum temperatures that would be reached in various parts of the bone during the cement setting process, to explore what negative effects this might have on neighbouring bone and nerve. A 12mm by 12mm window was cut from 12 porcine femoral shafts, and Palacos R+D cement injected into the defect. As cement set, bone surface temperature was measured using infra-red thermal imaging and thermocouples used to measure temperatures at the bone-cement interface, 5mm from the cement bolus, 10mm from cement bolus and an area running around the shaft replicating radial nerve. Bone surface temperature rose to a maximum of 34.0 C (on average), and 32.9 C in the ‘radial nerve’ thermocouple. Notably, in two bones there were fractures during specimen preparation, and maximum temperatures in these two areas exceeded 41 degrees C. Average maximum temperatures were 58.1 C, 36.5 C and 30.1 C at the bone cement interface, 5mm and 10mm from the cement bolus respectively


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 183 - 183
1 Sep 2012
Baker J Mullett H
Full Access

Purpose

The aim of this study was to report the outcomes of a series of patients with clavicle fracture non-union who had undergone open reduction and internal fixation using a contoured locking plate without the use of distant bone graft.

Methods

Patients were identified using the hospital database. Records were reviewed to determine basic demographics, operative findings, and radiological outcome. Patients were contacted and details about initial injury and treatment, and return to work and sport were recorded. Disabilities of Arm, Shoulder and Hand (DASH) for both operated and non-operated shoulders were completed.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 660 - 661
1 Jul 1995
Patankar H Kakatkar V Shah C Agashe V


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 129 - 129
1 May 2011
García-Rey E Garcia-Cimbrelo E Cruz-Pardos A
Full Access

Acetabular bone structure is not the same in all patients and can be defined by the radiolucent triangle superior to the acetabulum. We ask if the acetabular anatomy determines the initial cup fixation and screws use.

We have assessed 205 hips in which a Cerafit cementless cup was implanted. According to Dorr et al., acetabulae were classified as type A, in which the radiolucent triangle had an isosceles shape (86 hips), type B, in which the triangle extended into the teardrop (90 hips), and type C which had a right-angle triangle (29 hips). The use of screws was decided at the time of surgery and according to cup stability, not acetabular anatomy.

Avascular necrosis and inflammatory arthritis were the most frequent diagnoses in type A hips, osteoarthritis in type B, and dysplasia in type C. Women were more frequent in types A and C (p< 0.001). The use of screws was more frequent in women (p< 0.001) and in type A (34.9%) and type C hips (62.1%) than in type B hips (20.0%) (p< 0.001). The multivariate logistic regression model showed the acetabular type (p=0.11) and gender (p=0.003) as independent factors. Acetabular types A (OR=1.98, 95% CI: 0.922–4.208, p=0.075) and C (OR=5.09, 95% CI: 1.74–14.9, p=0.003) increase the risk for screw use. Men have a lower risk for screw use (OR=0.329, 95% CI: 0.16–0.68, p=0.003).

Acetabular anatomy and gender determine the use of screws in cementless cups. Continued follow-up is necessary to determine if screws results in less loosening and osteolysis.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 178 - 178
1 Mar 2008
Nasser S Poggie R
Full Access

Revision TKA patients who have severe patellar bone loss or undergo patellectomy often have inferior clinical results. Current treatments are limited and often unsatisfactory. This study reports the surgical technique and clinical follow-up (4-year minimum) for 10 patients who underwent revision or salvage TKA and received a porous tantalum implant for replacement of their patella.

The prosthesis is comprised of two parts, a poroustantalum base and titanium suture ring for initial fixation, and a polyethylene surface that is cemented to the base. The surgical technique evolved over the course of the first three cases, during which the suture technique and size (non-absorbable number 2) and bone preparation were defined.

The results of this study indicate that this porous tantalum patella is an effective prosthetic option that is capable of improving function and reducing pain for patients with severe patellar boneloss and complicating factors.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 376 - 376
1 Oct 2006
Murnaghan M McIlmurray L Mushipe M Li G
Full Access

The potential importance of bone morphogenic proteins (BMPs) to improve fracture healing is of great interest to orthopaedic surgeons. Although the complex mechanisms leading from the presence of local BMP (either endogenous or exogenous) to form bone is increasingly understood, however most appropriate time to administer exogenous BMP has yet to be elucidated. The purpose of this study was to investigate when BMP may be administered to a fracture arena in order to best improve fracture healing. Forty mice were randomised into 4 groups; (group I) control, treated at day 0 with placebo; (groups II, III and IV) treated with BMP at days 0, 4 and 8, respectively. All animals underwent a previously validated surgical procedure involving the creation of an open femoral fracture which is stabilised using a 4 pin external fixator. Thirty microlitres of bovine serum albumin (BSA) alone was used in group I, and the other groups (II, III and IV) were treated with a combination of the BSA and 2.5 microgrames of rhBMP-2. The BSA and rhBMP were injected through a lateral approach immediately after operation, or at 4, or 8 days postoperatively. At days 0, 8, 16 and 22, sequential radiographs were taken using a digital x-ray machine and at day 22 all animals were sacrificed. Both femora were harvested and assessed biomechanically in 3-point bending prior to fixation for histological evaluation. All data were analysed using Mann-Whitney U tests (SPSS, Version 9, Chicago, Illinois) and differences were considered significant at p < 0.05. X-ray analysis indicated that healing of fractures treated with BMP at day 0(group II) or day 4(group III) was significantly greater than that at both days 16 and 22 (p < 0.05) than those animals in placebo (group I) and BMP day 8(group V) treatment groups. Although the administration of BMP at day 4 seemed to cause more bone formation than treatment at day 0, no significant difference were observed. There were no differences between group IV and group I. Biomechanically, group III exhibited ultimate load values closest to the contralateral unoperated femora followed by group II, then IV and finally the control group I. Significant differences (p < 0.05) were observed between the control animals (group I) and both groups II and III. Qualitative histology suggested that at 22 days after surgery, only groups II and III had healed with woven bone. Group I and group IV had considerable amounts of fibrous tissue and cartilage at the fracture gap. This study suggests that a single percutaneous injection of BMP has a positive effect on fracture healing in this model, when prescribed between the time of injury (day 0) and 4 days. Data suggests that the most effective timing of delivery of BMP may not be at the time of surgery but actually in the early healing phase. The day 4 time point in the mouse model is likely to equate to that of 7–10 days in larger animals or humans. This suggests that current human treatment practices may require further investigation in order to elucidate the most appropriate time of delivery for these important proteins. This work may negate the current requirements for carrier products and large doses of these expensive drugs.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented base plates may confer fewer complications and revisions. Cite this article: Bone Joint J 2022;104-B(12):1334–1342


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims. Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures. Methods. The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed. Results. A total of 19 studies were included in the qualitative synthesis, and six comparative studies were included in the meta-analysis. Overall, 120 patients received locking-plate fixation with bone-graft augmentation, 179 patients received locking-plate fixation with cement augmentation, and 336 patients received locking-plate fixation without augmentation. No statistically relevant differences between the augmented and non-augmented cohorts were found in terms of the Disabilities of the Arm, Shoulder and Hand questionnaire score and Constant-Murley Score. The cement-augmented group had a significantly lower rate of complications compared to the non-augmented group. Conclusion. While locking-plate fixation with cement augmentation appears to produce a lower complication rate compared to locking-plate fixation alone, functional outcomes seem comparable between augmented and non-augmented techniques. Cite this article: Bone Joint J 2024;106-B(7):646–655


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 47 - 53
1 May 2024
Jones SA Parker J Horner M

Aims. The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss. Methods. We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis. Results. A total of 105 procedures were carried out in 100 patients (five bilateral) with a mean age of 73 years (42 to 94). In the IIIA defects treated, 72.0% (36 of 50) required a porous metal augment; the remaining 14 patients were treated with a hemispherical acetabular component alone. In the IIIB defects, 63.6% (35 of 55) underwent reconstruction as planned with 20 patients who actually required a hemispherical acetabular component alone. At mean follow-up of 7.6 years, survival was 94.3% (95% confidence interval 97.4 to 88.1) for all-cause revision and the overall dislocation rate was 3.8% (4 of 105). There was no difference observed in survival between type IIIA and type IIIB defects and whether a hemispherical implant alone was used for the reconstruction or not. The mean gain in OHS was 16 points. Custom-made implants were only used in six cases, in patients with either a mega-defect in which the anteroposterior diameter > 80 mm, complex pelvic discontinuity, and massive bone loss in a small pelvis. Conclusion. Our findings suggest that a reconstruction algorithm can provide a successful approach to reconstruction in major acetabular bone loss. The use of custom implants has been defined in this series and accounts for < 5% of cases. Cite this article: Bone Joint J 2024;106-B(5 Supple B):47–53


Full Access

Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft failure is the concern and ensuring a durable initial graft with rapid integration is crucial. Graft augmentation with implantable devices (internal brace reinforcement) is a technique purported to reduce the risk of rupture and hasten recovery. We aim to compare the short-term outcome of ACL-R using augmented hamstring tendon autografts (internally braced with neoligament) and non-augmented hamstring autografts. Methods. This was a retrospective cohort study comparing augmented and non-augmented ACL-R. All procedures were performed in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes. Results. There were 70 patients in the augmented and 111 patients in the control group. Mean graft diameter in the augmented group was 8.82mm versus 8.44mm in the non-augmented. Six strand graft was achievable in 73.5% of the augmented group compared to 33% in the non-augmented group. Two graft failures were reported in the non-augmented group and none in the augmented group. Patient satisfaction rates were higher in the augmented group. There was a statistically insignificant improvement in the postoperative KOOS in the augmented group compared to the non-augmented group (p 0.6). Irrespective of augmentation status, no correlation was found between the functional score and age, or femoral tunnel width. Conclusion. Augmented ACL-R may achieve superior graft diameters, lower failure rates and better patient reported outcomes when compared to nonaugmented ACL-R. Prospective trials are needed to examine this further


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 1 - 1
23 Jun 2023
Parker J Horner M Jones SA
Full Access

Contemporary acetabular reconstruction in major acetabular bone loss often involves the use of porous metal augments, a cup-cage construct or custom implant. The aims of this study were: To determine the reproducibility of a reconstruction algorithm in major acetabular bone loss. To determine the subsequent success of reconstruction performed in terms of re-operation, all-cause revision and Oxford Hip Score (OHS) and to further define the indications for custom implants in major acetabular bone loss. Consecutive series of Paprosky Type III defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical cup. IIIB defects were planned to receive either augment and cup, cup-cage or custom implant. 105 procedures in cohort 100 patients (5 bilateral) with mean age 73 years (42–94). IIIA defects (50 cases) − 72.0% (95%CI 57.6–82.1) required a porous metal augment the remainder treated with a hemispherical cup alone. IIIB defects (55 cases) 71.7% (95%CI 57.6–82.1) required either augments or cup-cage. 20 patients required a hemispherical cup alone and 6 patients received a custom-made implant. Mean follow up of 7.6 years. 6 re-revisions were required (4 PJI, 2 peri-prosthetic fractures & 1 recurrent instability) with overall survivorship of 94.3% (95% CI 97.4–88.1) for all cause revision. Single event dislocations occurred in 3 other patients so overall dislocation rate 3.8%. Mean pre-op OHS 13.8 and mean follow-up OHS 29.8. Custom implants were used in: Mega-defects where AP diameter >80mm, complex discontinuity and massive bone loss in a small pelvis (i.e., unable to perform cup-cage). A reconstruction algorithm can >70% successfully predict revision construct which thereafter is durable with a low risk of re-operation. Jumbo cup utilized <1/3 of cases when morphology allowed. The use of custom implants has been well defined in this series and accounts for <5% of cases


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2022
Mohan R Thomas T Kwaees T Pydisetty R
Full Access

Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft augmentation with suture tape (internal brace) are techniques purported to reduce the risk of rupture and hasten recovery. Our aim was to assess the short-term outcome of ACL-R using fibre tape augmented and non-augmented hamstring tendon grafts. Methods. This was a retrospective comparative study looking at augmented and non-augmented ACL-R. All procedures were performed by a single surgeon in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes. Results. There were 72 patients in the augmented and 132 patients in the control group. Confounding factors were comparable in both groups. The mean graft diameter in the augmented group was 8.81mm versus 8.01mm in the non-augmented. Six strand graft was achievable in 71% of the augmented group compared to 62.5% in the non-augmented group. Two graft failures reported in the non-augmented group and none in the augmented group. The average 14-month postoperative KOOS in the augmented group was 90.5 compared to an average 30-month score of 82.5 in the non-augmented group, which is statistically significant. Conclusion. Augmented ACL-R demonstrate statistically significant better patient-reported outcomes compared to the nonaugmented group. Graft failure rates may also be lower in augmented ACL-R


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 19 - 19
23 Feb 2023
Sandow M Cheng Z
Full Access

This paper presents an ongoing review of the use of a wedge-shaped porous metal augments in the shoulder to address glenoid retroversion as part of anatomical total shoulder arthroplasty (aTSA). Seventy-five shoulders in 66 patients (23 women and 43 men, aged 42 to 85 years) with Walch grade B2 or C glenoids underwent porous metal glenoid augment (PMGA) insertion as part of aTSA. Patients received either a 15º or 30º PMGA wedge (secured by screws to the native glenoid) to correct excessive glenoid retroversion before a standard glenoid component was implanted using bone cement. Neither patient-specific guides nor navigation were used. Patients were prospectively assessed using shoulder functional assessments (Oxford Shoulder Score [OSS], American Shoulder and Elbow Standardized Shoulder Assessment Form [ASES], visual analogue scale [VAS] pain scores and forward elevation [FE]) preoperatively, at three, six, and 12 months, and yearly thereafter, with similar radiological surveillance. Forty-nine consecutive series shoulders had a follow-up of greater than 24 months, with a median follow-up of 48 months (range: 24–87 months). Median outcome scores improved for OSS (21 to 44), ASES (24 to 92), VAS (7 to 0), and FE (90º to 140º). Four patients died, but no others were lost to follow-up. Apart from one infection at 18 months postoperatively and one minor peg perforation, there were no complications, hardware failures, implant displacements, significant lucency or posterior re-subluxations. Radiographs showed good incorporation of the wedge augment with correction of glenoid retroversion from median 22º (13º to 46º) to 4º. All but four glenoids were corrected to within the target range (less than 10º retroversion). The porous metal wedge-shaped augments effectively addressed posterior glenoid deficiency as part of aTSA for rotator cuff intact osteoarthritis, producing satisfactory clinical outcomes with no signs of impending future failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 63 - 63
17 Nov 2023
Bicer M Phillips AT Melis A McGregor A Modenese L
Full Access

Abstract. OBJECTIVES. Application of deep learning approaches to marker trajectories and ground reaction forces (mocap data), is often hampered by small datasets. Enlarging dataset size is possible using some simple numerical approaches, although these may not be suited to preserving the physiological relevance of mocap data. We propose augmenting mocap data using a deep learning architecture called “generative adversarial networks” (GANs). We demonstrate appropriate use of GANs can capture variations of walking patterns due to subject- and task-specific conditions (mass, leg length, age, gender and walking speed), which significantly affect walking kinematics and kinetics, resulting in augmented datasets amenable to deep learning analysis approaches. METHODS. A publicly available (. https://www.nature.com/articles/s41597-019-0124-4. ) gait dataset (733 trials, 21 women and 25 men, 37.2 ± 13.0 years, 1.74 ± 0.09 m, 72.0 ± 11.4 kg, walking speeds ranging from 0.18 m/s to 2.04 m/s) was used as the experimental dataset. The GAN comprised three neural networks: an encoder, a decoder, and a discriminator. The encoder compressed experimental data into a fixed-length vector, while the decoder transformed the encoder's output vector and a condition vector (containing information about the subject and trial) into mocap data. The discriminator distinguished between the encoded experimental data from randomly sampled vectors of the same size. By training these networks jointly using the experimental dataset, the generator (decoder) could generate synthetic data respecting specified conditions from randomly sampled vectors. Synthetic mocap data and lower limb joint angles were generated and compared to the experimental data, by identifying the statistically significant differences across the gait cycle for a randomly selected subset of the experimental data from 5 female subjects (73 trials, aged 26–40, weighing 57–74 kg, with leg lengths between 868–931 mm, and walking speeds ranging from 0.81–1.68 m/s). By conducting these comparisons for this subset, we aimed to assess the synthetic data generated using multiple conditions. RESULTS. We visually inspected the synthetic trials to ensure that they appeared realistic. The statistical comparison revealed that, on average, only 2.5% of the gait cycle showed significantly differences in the joint angles of the two data groups. Additionally, the synthetic ground reaction forces deviated from the experimental data distribution for an average of 2.9% of the gait cycle. CONCLUSIONS. We introduced a novel approach for generating synthetic mocap data of human walking based on the conditions that influence walking patterns. The synthetic data closely followed the trends observed in the experimental data, also in the literature, suggesting that our approach can augment mocap datasets considering multiple conditions, an approach unfeasible in previous work. Creation of large, augmented datasets allows the application of other deep learning approaches, with the potential to generate realistic mocap data from limited and non-lab-based data. Our method could also enhance data sharing since synthetic data does not raise ethical concerns. You can generate and download virtual gait data using our GAN approach from . https://thisgaitdoesnotexist.streamlit.app/. . Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 2 - 2
23 Jun 2023
Hube R Zimmerer A Nonnenmacher L Najfeld M Fischer M Wassilew GI
Full Access

The use of trabecular metal (TM.) shells supported by two TM augments in the footing technique has been described as a potential option for the treatment of Paprosky 3B acetabular defects. The aim of this study was to assess the mid implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. We undertook a retrospective, double-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the footing technique using a TM shell supported by two TM augments, for severe acetabular bone loss between 2007 and 2020. The mean age at the time of surgery was 62,9 (28 to 86) years. The mean follow-up was 5,4 (1,5 to 15) years. The cumulative mid survivorship of the implant with revision for any cause was 89%. 3 hips (7,6%) required further revision due to aseptic loosening, and 1 (2,8%) required revision for infection. The mean Harris Hip Score improved significantly from 48 (29 to 65) preoperatively to 79 points (62 to 98) at the latest follow-up (p < 0.001). The reconstruction of Paprosky 3B acetabular defects with TM shells and two augments in footing-technique showed excellent mid-term results. This technique appears to be a viable option for treating these defects


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 92 - 92
17 Apr 2023
Raina D Mrkonjic F Tägil M Lidgren L
Full Access

A number of techniques have been developed to improve the immediate mechanical anchorage of implants for enhancing implant longevity. This issue becomes even more relevant in patients with osteoporosis who have fragile bone. We have previously shown that a dynamic hip screw (DHS) can be augmented with a calcium sulphate/hydroxyapatite (CaS/HA) based injectable biomaterial to increase the immediate mechanical anchorage of the DHS system to saw bones with a 400% increase in peak extraction force compared to un-augmented DHS. The results were also at par with bone cement (PMMA). The aim of this study was to investigate the effect of CaS/HA augmentation on the integration of a different fracture fixation device (gamma nail lag-screw) with osteoporotic saw bones. Osteoporotic saw bones (bone volume fraction = 15%) were instrumented with a gamma nail without augmentation (n=8) or augmented (n=8) with a CaS/HA biomaterial (Cerament BVF, Bonesupport AB, Sweden) using a newly developed augmentation method described earlier. The lag-screws from both groups were then pulled out at a displacement rate of 0.5 mm/s until failure. Peak extraction force was recorded for each specimen along with photographs of the screws post-extraction. A non-parametric t-test was used to compare the two groups. CaS/HA augmentation of the lag-screw led to a 650% increase in the peak extraction force compared with the controls (p<0.01). Photographs of the augmented samples shows failure of the saw-bones further away from the implant-bone interface indicating a protective effect of the CaS/HA material. We present a novel method to enhance the immediate mechanical anchorage of a lag-screw to osteoporotic bone and it is also envisaged that CaS/HA augmentation combined with systemic bisphosphonate treatment can lead to new bone formation and aid in the reduction of implant failures and re-operations


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 23 - 23
1 Jul 2022
Frame M Hauck O Newman M
Full Access

Abstract. Introduction. Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture. To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation. Methods. Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws. The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups. Results. The augmented group showed less cyclic tubercular fragment displacement after every load level compared with the standard group, with statistically significant differences starting from 500 N (P < .05; power > 0.8). Mean ± standard deviation tubercular fragment displacement at the end of cyclic loading was 2.56 ± 0.82 mm for the augmented group and 5.21 ± 0.51 mm for the standard group. Mean ultimate failure load after the pull-to-failure test was 2475 ± 554 N for the augmented group and 1475 ± 280 N for the standard group. Conclusion. The specimens that underwent suture tape augmentation showed less tubercular fragment displacement during cyclic loading and higher ultimate failure forces compared with those that underwent standard screw fixation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 39 - 39
1 Aug 2021
Rajan A Leong J Singhal R Siney P Shah N Board T
Full Access

Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre. A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications. Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded. This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory clinical and radiographic results. Long term studies are needed to assess the possibility of preservation and regeneration of bone stock


We performed this systematic overview on the overlapping meta-analyses that analyzed autologous platelet-rich plasma (PRP) as an adjuvant in the repair of rotator cuff tears and identify the studies which provide the current best evidence on this subject and generate recommendations for the same. We conducted independent and duplicate electronic database searches in PubMed, Web of Science, Scopus, Embase, Cochrane Database of Systematic Reviews, and the Database of Abstracts of Reviews of Effects on September 8, 2021, to identify meta-analyses that analyzed the efficacy of PRP as an adjuvant in the repair of rotator cuff tears. Methodological quality assessment was made using Oxford Levels of Evidence, AMSTAR scoring, and AMSTAR 2 grades and used the Jadad decision algorithm to generate recommendations. 20 meta-analyses fulfilling the eligibility criteria were included. The AMSTAR scores of the included studies varied from 6–10 (mean:7.9). All the included studies had critically low reliability in their summary of results due to their methodological flaws according to AMSTAR 2 grades. The initial size of the tear and type of repair performed do not seem to affect the benefit of PRPs. Among the different preparations used, leucocyte poor (LP)-PRP possibly offers the greatest benefit as a biological augment in these situations. Based on this systematic overview, we give a Level II recommendation that intra-operative use of PRPs at the bone-tendon interface can augment the healing rate, reduce re-tears, enhance the functional outcomes and mitigate pain in patients undergoing arthroscopic rotator cuff repair


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup. 360. looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 22 - 22
2 Jan 2024
Muller S
Full Access

Tendons mainly consist of collagen in order to withstand high tensile forces. Compared to other, high turnover tissues, cellularity and vascularity in tendons are low. Thus, the natural healing process of tendons takes long and can be problematic. In case of injury to the enthesis, the special transition from tendon over cartilage to bone is replaced by a fibrous scar tissue, which remains an unsolved problem in rotator cuff repair. To improve tendon healing, many different approaches have been described using scaffolds, stem cells, cytokines, blood products, gene therapy and others. Despite promising in vitro and in vivo results, translation to patient care is challenging. In clinics however, tendon auto- or allografts remain still first choice to augment tendon healing if needed. Therefore, it is important to understand natural tendon properties and natural tendon healing first. Like in other tissues, senescence of tenocytes seems to play an important role for tendon degeneration which is interestingly not age depended. Our in vivo healing studies have shown improved and accelerated healing by adding collagen type I, which is now used in clinics, for example for augmentation of rotator cuff repair. Certain cytokines, cells and scaffolds may further improve tendon healing but are not yet used routinely, mainly due to missing clinical data, regulatory issues and costs. In conclusion, the correct diagnosis and correct first line treatment of tendon injuries are important to avoid the necessity to biologically augment tendon healing. However, strategies to improve and accelerate tendon healing are still desirable. New treatment opportunities may arise with further advances in tendon engineering in the future


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 41 - 41
2 Jan 2024
Singh S Dhar S Kale S
Full Access

The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics. Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 108 - 108
10 Feb 2023
Guo J Blyth P Clifford K Hooper N Crawford H
Full Access

Augmented reality simulators offer opportunities for practice of orthopaedic procedures outside of theatre environments. We developed an augmented reality simulator that allows trainees to practice pinning of paediatric supracondylar humeral fractures (SCHF) in a radiation-free environment at no extra risk to patients. The simulator is composed of a tangible child's elbow model, and simulated fluoroscopy on a tablet device. The treatment of these fractures is likely one of the first procedures involving X-ray guided wire insertion that trainee orthopaedic surgeons will encounter. This study aims to examine the extent of improvement simulator training provides to real-world operating theatre performance. This multi-centre study will involve four cohorts of New Zealand orthopaedic trainees in their SET1 year. Trainees with no simulator exposure in 2019 - 2021 will form the comparator cohort. Trainees in 2022 will receive additional, regular simulator training as the intervention cohort. The comparator cohort's performance in paediatric SCHF surgery will be retrospectively audited using routinely collected operative outcomes and parameters over a six-month period. The performance of the intervention cohorts will be collected in the same way over a comparable period. The data collected for both groups will be used to examine whether additional training with an augmented reality simulator shows improved real-world surgical outcomes compared to traditional surgical training. This protocol has been approved by the University of Otago Health Ethics committee, and the study is due for completion in 2024. This study is the first nation-wide transfer validity study of a surgical simulator in New Zealand. As of September 2022, all trainees in the intervention cohort have been recruited along with eight retrospective trainees via email. We present this protocol to maintain transparency of the prespecified research plans and ensure robust scientific methods. This protocol may also assist other researchers conducting similar studies within small populations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 6 - 6
2 May 2024
Langdown A Goriainov V Watson R
Full Access

Gluteal Tendinopathy is a poorly understood condition that predominantly affects post-menopausal women. It causes lateral hip pain, worse when lying on the affected side or when walking up a hill or stairs. It has been labelled ˜Greater Trochanteric Pain Syndrome” a name that recognises the lack of understanding of the condition. Surgical reconstruction of the gluteal cuff is well established and has been undertaken numerous times over the last 16 years by the senior author (AJL). However, the quality of collagen in the tendons can be very poor and this leads to compromised results. We present the results of gluteal cuff reconstruction combined with augmentation using a bioinductive implant. 14 patients (11 female, 3 male; mean age 74.2 ± 6.3 years) with significant symptoms secondary to gluteal tendinopathy that had failed conservative treatment (ultrasound guided injection and structured physiotherapy) underwent surgical reconstruction by the senior author using an open approach. In all cases the iliotibial band was lengthened and the trochanteric bursa excised. The gluteal cuff was reattached using Healicoil anchors (3–5×4.75mm anchors; single anchors but double row repair) and then augmented using a Regeneten patch. Patients were mobilised fully weight bearing post-operatively but were asked to use crutches until they were no longer limping. All had structured post-surgery rehabilitation courtesy of trained physiotherapists. There were no post-operative complications and all patients reported an improvement in pain levels (Visual Analogue Scale 7.8 pre-op; 2.6 post-op) and functional levels (UCLA Activity Score 3.5 pre-op; 7.1 post-op) at 6 months post surgery. Surgery for gluteal tendinopathy produces good outcomes and the use of Regeneten as an augment for poor quality collagen is seemingly a safe, helpful addition. Further comparative studies would help clarify this


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 6 - 6
17 Jun 2024
Ahluwalia R Wek C Lewis T Stringfellow T Coffey D Ping S Edmonds M Reichert I
Full Access

Background. Ankle fractures associated with diabetes experience more complications following standard Open-Reduction-Internal-Fixation (ORIF) than those without diabetes. Augmented fixation strategies namely extended ORIF and hind-foot-nail (HFN) may offer better results, and early weightbearing in this group. The aim of this study was to define the population of patients with diabetes undergoing primary fixation for ankle fractures. Secondarily, to assess the utilisation of standard and augmented strategies and the effect of these choices on surgical outcomes including early post-operative weight bearing and surgical complications. Methods. A national-multicentre retrospective cohort study was conducted between January to June 2019 in 56 centres (10 Major- Trauma-Centres and 46 Trauma-Units) in the United Kingdom; 1360 specifically defined complex ankle-fractures were enrolled. Demographics, fixation choice, surgical and functional outcomes were recorded. Statistical analysis was performed to compare high-risk patients with/without diabetes. Results. There were 316 patients in the diabetes cohort with mean age 63.9yrs (vs. 49.3yrs in non-diabetes cohort), and greater frailty score >4 (24% vs.14% (non-diabetes cohort) (p<0.03); 7.5% had documented neuropathy. In the diabetes cohort, 79.7% underwent standard ORIF, 7.1% extended ORIF and 10.2% a HFN compared to 87.7%, 3.0% and 10.3% in the non-diabetes cohort. Surgical wound complications after standard-ORIF were higher in the diabetes cohort (15.1% vs. 8.7%) (p<0.02) but patients with diabetes who underwent augmented techniques showed little difference in surgical outcomes/complications to non-diabetes, even though early-weight- bearing rates were greater than standard-ORIF. Conclusion. Ankle fractures in diabetes occur in older, frailer patients; whilst lower than expected neuropathy rates suggest a need for improved assessment. Augmented surgical techniques may allow earlier weight-bearing without increasing complications in keeping with modern guidelines in ankle fracture management


Bone & Joint Research
Vol. 12, Issue 3 | Pages 219 - 230
10 Mar 2023
Wang L Li S Xiao H Zhang T Liu Y Hu J Xu D Lu H

Aims. It has been established that mechanical stimulation benefits tendon-bone (T-B) healing, and macrophage phenotype can be regulated by mechanical cues; moreover, the interaction between macrophages and mesenchymal stem cells (MSCs) plays a fundamental role in tissue repair. This study aimed to investigate the role of macrophage-mediated MSC chondrogenesis in load-induced T-B healing in depth. Methods. C57BL/6 mice rotator cuff (RC) repair model was established to explore the effects of mechanical stimulation on macrophage polarization, transforming growth factor (TGF)-β1 generation, and MSC chondrogenesis within T-B enthesis by immunofluorescence and enzyme-linked immunosorbent assay (ELISA). Macrophage depletion was performed by clodronate liposomes, and T-B healing quality was evaluated by histology and biomechanics. In vitro, bone marrow-derived macrophages (BMDMs) were stretched with CELLOAD-300 load system and macrophage polarization was identified by flow cytometry and quantitative real-time polymerase chain reaction (qRT-PCR). MSC chondrogenic differentiation was measured by histochemical analysis and qRT-PCR. ELISA and qRT-PCR were performed to screen the candidate molecules that mediated the pro-chondrogenic function of mechanical stimulated BMDMs. Results. Mechanical stimulation promoted macrophage M2 polarization in vivo and in vitro. The conditioned media from mechanically stimulated BMDMs (MS-CM) enhanced MSC chondrogenic differentiation, and mechanically stimulated BMDMs generated more TGF-β1. Further, neutralizing TGF-β1 in MS-CM can attenuate its pro-chondrogenic effect. In vivo, mechanical stimulation promoted TGF-β1 generation, MSC chondrogenesis, and T-B healing, which were abolished following macrophage depletion. Conclusion. Macrophages subjected to appropriate mechanical stimulation could polarize toward the M2 phenotype and secrete TGF-β1 to promote MSC chondrogenesis, which subsequently augments T-B healing. Cite this article: Bone Joint Res 2023;12(3):219–230


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1292 - 1303
1 Dec 2022
Polisetty TS Jain S Pang M Karnuta JM Vigdorchik JM Nawabi DH Wyles CC Ramkumar PN

Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered. Cite this article: Bone Joint J 2022;104-B(12):1292–1303


Abstract. Objectives. The principle of osteoporotic vertebral compression fracture (OVCF) is fixing instability, providing anterior support, and decompression. Contraindication for vertebroplasty is anterior or posterior wall fracture. The study objectives was to evaluate the efficacy and safety of vertebroplasty with short segmented PMMA cement augmented pedicle screws for OVCF with posterior/anterior wall fracture patients. Methods. A retrospective study of 24 patients of DGOU type-4 (vertebra plana) OVCF with posterior/anterior wall fracture, were treated by vertebroplasty and short segment PMMA cement augmented pedicle screws fixation. Radiological parameters (kyphosis angle and compression ratio) and clinical parameters Visual analogue scale (VAS) and Oswestry disability index (ODI) were analysed. Results. A significant improvement was noted in VAS (preoperative, 7.90 ±0.60; final follow-up 2.90 ± 0.54) and ODI (77.10 ± 6.96 to 21.30 ± 6.70), (P < 0.05). Neurological improvement was noted in all patients. Kyphosis corrected significantly from preoperative 23.20±5.90 to 5.30±1.40 postoperative with 5% (3.30± 2.95) loss of correction at final follow-up. Anterior vertebral height restored significantly from 55.80±11.9% t0 87.6±13.1% postoperative with 4.5±4.0% loss at final follow-up. One case had cement leakage was found, but the patient is asymptomatic. No implant-related complication was seen. No iatrogenic dural or nerve injury. Conclusions. Treatment with vertebroplasty with cement augmented screw fixation and direct decompression is a great option in treating such a complex situation in fragile age with fragile bones because It provides anterior support with cementing that avoids corpectomy. Short segment fixation has less stress risers at the junctional area


Abstract. Objectives. To evaluate the safety and efficacy of vertebroplasty with short segmented cement augmented pedicle screws fixation for severe osteoporotic vertebral compression fractures (OVCF) with posterior/anterior wall fractured patients. Methods. A retrospective study of 24 patients of DGOU type-4 (vertebra plana) OVCF with posterior/anterior wall fracture, were treated by vertebroplasty and short segment PMMA cement augmented pedicle screws fixation. Radiological parameters (kyphosis angle and compression ratio) and clinical parameters Visual analogue scale (VAS) and Oswestry disability index (ODI) were analysed. Results. A significant improvement was noted in VAS (preoperative, 7.90 ± 0.60; final follow-up 2.90 ± 0.54) and ODI (77.10 ± 6.96 to 21.30 ± 6.70), (P < 0.05). Neurological improvement was noted in all patients. Kyphosis corrected significantly from preoperative 23.20 ± 5.90 to 5.30 ± 1.40 postoperative with 5% (3.30 ± 2.95) loss of correction at final follow-up. Anterior vertebral height restored significantly from 55.80 ± 11.9% to 87.6 ± 13.1% postoperative with 4.5 ± 4.0% loss at final follow-up. One case had cement leakage was found, but the patient is asymptomatic. No implant-related complication was seen. No iatrogenic dural or nerve injury. Conclusions. Treatment with vertebroplasty with cement augmented screw fixation and direct decompression is a great option in treating such a complex situation in fragile age with fragile bones because. Vertebroplasty is viable option for restoring vertebral anterior column in patients who are considered as contraindications for vertebroplasty, like DGOU-4. It provides anterior support avoiding corpectomy, minimise blood loss and also duration of surgery. Addition of short segment fixation gives adequate support with less stress risers at the junctional area


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 72 - 72
11 Apr 2023
Stich T Kovářík T Křenek T Alt V Docheva D
Full Access

The goal was to analyze the cellular response, specifically the osteogenic capacity, of titanium (Ti) implants harbouring a novel laserbased-surface-structure with the overall aim: augmented osteointegration. Surface micro-/nanoproperties greatly influence cell behaviour at the tissue-implant-interface and subsequent osteointegration. We investigated Ti-materials subjected to a specially developed shifted-Laser-Surface-Texturing (sLST) technology and compared them to a standard roughening-technique (sand-blasting-acid-etching, SLA). The biological response was evaluated with hMSCs, which are naturally available at the bone-implant-interface. We hypothesized: the novel surface is beneficial for our three different (young/healthy-YH; aged/healthy-AH;aged/osteoporotic-OP) cohorts. The sLST was performed using a SPI-G3-series laser (beam-wavelength=1064nm, pulse-duration=200ns). For the SLA surface, Ti was sandblasted, afterwards acid-etched (HCl/H2SO4). Three different hMSC cohorts were studied: YH: n=6,29±6; AH: n=5,79±5; OP: n=5,76±5 years (osteoporosis confirmed via DEXA-scan). OP hMSCs show e.g. ColI-deficient-matrix and decreased mineralization. Cells were examined for survival, cell proliferation and cytoskeleton arrangement. Osteogenic differentiation was carried out over 21 days, matrix mineralization was validated with Alizarin-Red-S-staining and quantification. Laser-texturing generated precisely the desired microgeometry. On nanostructural level, differently-sized Ti-droplets were formed stochastically by laser-induced-Ti-plasma. Live/dead-/Actin-stainings showed comparable results for all cohorts and surfaces in terms of survival and cell shape. On Ti-materials, cell growth showed no significant difference between the 3 cohorts. Alizarin quantification revealed the highest levels on laser-textured-surfaces; highest value for YH, followed by AH, lastly OP; no significance between AH/YH, but between OP/YH (p<0.0001). However, mineralization of all cohorts cultured on laser-textured-surfaces increased significantly (p<0.0001) compared to respective SLA-group, with >20fold higher value in the OP-cohort (AH:11fold, YH:6fold). The data proves the biocompatibility of the laser-structured-Ti for young+aged cohorts. Osteogenic differentiation was significantly augmented on laser-treated-Ti. Most intriguingly, OP-donors could reach manifold increased mineralization, suggesting the novel laser texturing can counteract the osteoporotic phenotype. As osteogenesis-enhancing capacities may be related to mechanisms controlling cellular shape/fate, further investigations referring to this are currently ongoing. In conclusion, our laser-textured-Ti-materials are safe, can have a demand-oriented designer-surface-topography and represent a great potential for development into next-generation-implants suitable for different patient-cohorts, especially osteoporosis patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 5 - 5
1 Dec 2022
Li T Beaudry E Westover L Chan R
Full Access

The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until graft failure; if samples did not fail during the protocol, they were then loaded to failure. Samples were visually inspected for mode of failure after the protocol. A one-way analysis of variance was used to compare average tendon diameter; post-hac Tuhey tests were used to compare elongation and elongation rate. Survival to cyclic loading was analyzed using Kaplan-Meier survival curves with log rank. Statistical significance was set at a = 0.05. The average tendon diameter of each group was not statistically different [4.17 mm (tendon only), 4.33 mm (FiberLoop spaced 6 mm), and 4.30 mm (FiberLoop spaced 12 mm)]. The average survival of tendon augmented with FiberLoop was significantly higher than tendon only, and all groups had significantly improved survival compared to suture only. There was no difference in survival between FiberLoop spaced 6 mm and 12 mm. Elongation was significantly lower with suture compared to tendon augmented with FiberLoop spaced 6 mm. Elongation rate was significantly lower with suture compared to all groups. Modes of failure included rupture of the tendon, suture, or both at the simulated bone and suture and/or tendon interface, and elongation of the entire construct without rupture. In this biomechanical study, augmentation of porcine tendons with FiberLoop suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol, as suture material was significantly stiffer than any of the tendon graft configurations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 17 - 17
1 Jun 2021
Lane P Murphy W Harris S Murphy S
Full Access

Problem. Total hip replacement (THA) is among the most common and highest total spend elective operations in the United States. However, up to 7% of patients have 90-day complications after surgery, most frequently joint dislocation that is related to poor acetabular component positioning. These complications lead to patient morbidity and mortality, as well as significant cost to the health system. As such, surgeons and hospitals value navigation technology, but existing solutions including robotics and optical navigation are costly, time-consuming, and complex to learn, resulting in limited uptake globally. Solution. Augmented reality represents a navigation solution that is rapid, accurate, intuitive, easy to learn, and does not require large and costly equipment in the operating room. In addition to providing cutting edge technology to specialty orthopedic centers, augmented reality is a very attractive solution for lower volume and smaller operative settings such as ambulatory surgery centers that cannot justify purchases of large capital equipment navigation systems. Product. HipInsight™ is an augmented reality solution for navigation of the acetabular component in THA. HipInsight is a navigation solution that includes preoperative, cloud based surgical planning based on patient imaging and surgeon preference of implants as well as intraoperative guidance for placement of the acetabular component. Once the patient specific surgical plan is generated on the cloud-based planning system, holograms showing the optimal planned position of the acetabular component are exported in holographic format to a Microsoft HoloLens 2™, which the surgeon wears during placement of the acetabular component in total hip arthroplasty. The pelvis is registered using the HipXpert™ mechanical registration device, which takes 2–3 minutes to dock in the operating room. The surgeon then is able to view the patient's anatomy and optimal placement of the acetabular component under the skin in augmented reality. The surgeon then aligns the real cup impactor with the augmented reality projection of the cup impactor resulting in precise placement of the cup. Timescales. HipInsight was FDA cleared on January 28, 2021 for intraoperative use for placement of the acetabular component in total hip arthroplasty. The first case was performed in February 2021, and the product was launched to a select group of orthopedic surgeons in March 2021. Funding. HipInsight has been self-funded to date, and is beginning to engage in discussions to raise capital for a rapidly scaling commercial launch


Bone & Joint Research
Vol. 11, Issue 12 | Pages 854 - 861
1 Dec 2022
Park TJ Park SY Cho W Oh H Lee HJ Abd El-Aty AM Bayram C Jeong JH Jung TW

Aims. Myokine developmental endothelial locus-1 (DEL-1) has been documented to alleviate inflammation and endoplasmic reticulum (ER) stress in various cell types. However, the effects of DEL-1 on inflammation, ER stress, and apoptosis in tenocytes remain unclear. Methods. Human primary tenocytes were cultured in palmitate (400 μM) and palmitate plus DEL-1 (0 to 2 μg/ml) conditions for 24 hours. The expression levels of ER stress markers and cleaved caspase 3, as well as phosphorylated 5' adenosine monophosphate-activated protein kinase (AMPK) and autophagy markers, were assessed by Western blotting. Autophagosome formation was measured by staining with monodansylcadaverine, and apoptosis was determined by cell viability assay and caspase 3 activity assay. Results. We found that treatment with DEL-1 suppressed palmitate-induced inflammation, ER stress, and apoptosis in human primary tenocytes. DEL-1 treatment augmented LC3 conversion and p62 degradation as well as AMPK phosphorylation. Moreover, small interfering RNA for AMPK or 3-methyladenine (3-MA), an autophagy inhibitor, abolished the suppressive effects of DEL-1 on inflammation, ER stress, and apoptosis in tenocytes. Similar to DEL-1, 5-aminoimidazole-4-carboxamide ribonucleotide (AICAR), an activator of AMPK, also attenuated palmitate-induced inflammation, ER stress, and apoptosis in tenocytes, which 3-MA reversed. Conclusion. These results revealed that DEL-1 suppresses inflammation and ER stress, thereby attenuating tenocyte apoptosis through AMPK/autophagy-mediated signalling. Thus, regular exercise or administration of DEL-1 may directly contribute to improving tendinitis exacerbated by obesity and insulin resistance. Cite this article: Bone Joint Res 2022;11(12):854–861


Bone & Joint Research
Vol. 11, Issue 8 | Pages 561 - 574
10 Aug 2022
Schulze-Tanzil GG Delgado Cáceres M Stange R Wildemann B Docheva D

Tendon is a bradytrophic and hypovascular tissue, hence, healing remains a major challenge. The molecular key events involved in successful repair have to be unravelled to develop novel strategies that reduce the risk of unfavourable outcomes such as non-healing, adhesion formation, and scarring. This review will consider the diverse pathophysiological features of tendon-derived cells that lead to failed healing, including misrouted differentiation (e.g. de- or transdifferentiation) and premature cell senescence, as well as the loss of functional progenitors. Many of these features can be attributed to disturbed cell-extracellular matrix (ECM) or unbalanced soluble mediators involving not only resident tendon cells, but also the cross-talk with immigrating immune cell populations. Unrestrained post-traumatic inflammation could hinder successful healing. Pro-angiogenic mediators trigger hypervascularization and lead to persistence of an immature repair tissue, which does not provide sufficient mechano-competence. Tendon repair tissue needs to achieve an ECM composition, structure, strength, and stiffness that resembles the undamaged highly hierarchically ordered tendon ECM. Adequate mechano-sensation and -transduction by tendon cells orchestrate ECM synthesis, stabilization by cross-linking, and remodelling as a prerequisite for the adaptation to the increased mechanical challenges during healing. Lastly, this review will discuss, from the cell biological point of view, possible optimization strategies for augmenting Achilles tendon (AT) healing outcomes, including adapted mechanostimulation and novel approaches by restraining neoangiogenesis, modifying stem cell niche parameters, tissue engineering, the modulation of the inflammatory cells, and the application of stimulatory factors. Cite this article: Bone Joint Res 2022;11(8):561–574


Bone & Joint Research
Vol. 9, Issue 9 | Pages 534 - 542
1 Sep 2020
Varga P Inzana JA Fletcher JWA Hofmann-Fliri L Runer A Südkamp NP Windolf M

Aims. Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). Methods. A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. Results. The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. Conclusion. The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 43 - 43
1 Dec 2020
Sas A Sermon A van Lenthe GH
Full Access

Prophylactic treatment is advised for metastatic bone disease patients with a high risk of fracture. Clinicians face the task of identifying these patients with high fracture risk and determining the optimal surgical treatment method. Subject-specific finite element (FE) models can aid in this decision process by predicting the mechanical effect of surgical treatment. In this study, we specifically evaluated the potential of FE models to simulate femoroplasty, as uncertainty remains whether this prophylactic procedure provides sufficient mechanical strengthening to the weight-bearing femur. In eight pairs of human cadaveric femurs artificial metastatic lesions were created. In each pair, an identical defect was milled in the left and right femur. Four pairs received a spherical lesion in the neck and the other four an ellipsoidal lesion in the intertrochanteric region, each at the medial, superior/lateral, anterior and posterior side, respectively. One femur of each pair was augmented with polymethylmethacrylate (5–10 ml), while the contralateral femur was left untreated. CT scans were made at three different time points: from the unaffected intact femurs, the defect femurs with lesion and the augmented femurs. Bone strength was measured by mechanical testing until failure in eight defect and eight augmented femurs. Nonlinear CT-based FE models were developed and validated against the experimentally measured bone strength. Subsequently, the validated FE model was applied to the available CT scans for the three different cases: intact (16 scans), defect (16) and augmented (8). The FE predicted strength was compared for the three different cases. The FE models predicted the experimental bone strength with a strong correspondence, both for the defect (R. 2. = 0.97, RMSE= 0.75 kN) and the augmented femurs (R. 2. = 0.90, RMSE = 0.98 kN). Although all lesions had a “moderate” to “high” risk for fracture according to the Mirels’ scoring system (score 7 or 8), three defect femurs did not fracture through the lesion (intertrochanteric anterior, lateral and posterior), indicating that these lesions did not act as a critical weak spot. In accordance with the experimental findings, the FE models indicated almost no reduction in strength between the intact and defect state for these femurs (0.02 ± 0.1%). For the remaining “critical” lesions, bone strength was reduced with 15.7% (± 14.9%) on average. The largest reduction was observed for lesions on the medial side (up to 43.1%). For the femurs with critical lesions, augmentation increased bone strength with 29.5% (± 29.7%) as compared to the defect cases, reaching strength values that were 2.5% (± 3.7%) higher than the intact bone strength. Our findings demonstrate that FE models can accurately predict the experimental bone strength before and after augmentation, thereby enabling to quantify the mechanical benefit of femoroplasty. This way FE models could aid in identifying suitable patients for whom femoroplasty provides sufficient increase in strength. For all lesions evaluated in this study, femoroplasty effectively restored the initial bone strength. Yet, additional studies on larger datasets with a wide variation of lesion types are required to confirm these results


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 136 - 136
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION. 3D preoperative planning software for anatomic and reverse total shoulder arthroplasty (ATSA and RTSA) provides additional insight for surgeons regarding implant selection and placement. Interestingly, the advent of such software has brought previously unconsidered questions to light on the optimal way to plan a case. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current glenoid implant selection and placement. METHODS. 172 ASES members completed an 18-question survey on their thought process for how they select and place a glenoid implant for both ATSA and RTSA procedures. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into three cohorts based on their responses to usage of 3D preoperative planning software: high users, seldom users, and non-users. Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement. RESULTS. 76 surgeons were grouped into the high user cohort, 66 into the seldom user cohort, and 30 into the non-user cohort. 61.9% of high users and 74.1% of seldom users performed >75 shoulder arthroplasties per year, whereas only 19.9% of non-users performed >75 arthroplasties per year (Figure 1). When questioned on glenoid implant type selection (augmented vs. non-augmented components), 80.3% of high users reported augment usage for both ATSA and RTSA, with using augments >45% of the time in 18.4% of ATSA cases and in 22.3% of RTSA cases. For seldom users, 80.3% reported augment usage in ATSA cases, and 70.3% in RTSA cases. Seldom users reported augment usage >45% of the time in 4.5% of ATSA cases and in 1.6% of RTSA cases. For non-preoperative planning users, 53.3% reported using augments in ATSA cases, and 48.3% for RTSA cases. Non-users used augmented glenoid components >45% of the time in 6.6% of ATSA cases and in 6.8% of RTSA cases. For resultant implant superior inclination in RTSA, 40.8% of high users aim for 0° of inclination, followed by 31.8% for seldom users and 16.7% of non-users (Figure 2). CONCLUSION. The results of this study show that 3D preoperative planning software has an influence on the decision making process when planning a shoulder arthroplasty. High volume shoulder arthroplasty surgeons report higher preoperative planning software usage than low volume surgeons, suggesting the utility of such software. Augmented glenoid component usage for both ATSA and RTSA is also higher for surgeons that use preoperative planning software, which either suggests the utility of augmented glenoid components, or that the use of such software creates the perceived need for augmented glenoid components. Lastly, surgeons who preoperatively plan tend to orient their glenoid components differently, which could suggest either a better understanding of the anatomy through the use of the software, or an influence on mindset regarding implant orientation resulting from software usage. This highlights an area for future work that could correlate clinical outcome data to implant selection and placement to prove what is the optimal plan for a given patient. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2019
Dharia M Armacost J Son Y
Full Access

INTRODUCTION. Porous metal bone fillers are frequently used to manage bony defects encountered in revision total knee arthroplasty (rTKA). Compared to structural graft, porous metal bone fillers have shown significantly lower loosening and failure rates potentially due to osseointegration and increased material strength [1]. The strength of porous metal bone fillers used in lower extremities is frequently assessed using compression/shear/torsion test methods, adapted from spine standards. However, these basic methods may lack clinical relevance, and do not provide any insight on the relationship between patient activity and anticipated prosthesis performance. The goal of this study was to evaluate the response of bone fillers under different activities of daily living, in order to define physiologically relevant worst case biomechanics for component evaluation. METHODS. A bone filler tibial augment is shown in Figure 1. A test construct for tibial augments (half-block each for medial and lateral sides) is shown in Figure 2, along with compatible rTKA components. An additional void in the bone was filled using bone cement. Loading was applied through the tibiofemoral contact patches created on polyethylene tibial insert. Loading was used for two activities of daily living; walking and deep knee bend [2–3]. During walking, the tibiofemoral contact patch on the anterior tibial post gets loaded due to femoral hyperextension with 1.2xbody weight (BW), whereas the medial and lateral condyles get loaded with 3xBW compressive load. For deep knee bend, only the condyles get loaded with 4.34xBW. Compared to walking, 45% higher compressive load magnitude in deep knee bend located further posterior was anticipated to create a larger bending moment and induce higher stress on the half augments. A finite element analysis (FEA) was performed by modeling this test construct with a medium size tibial augment. All components were modeled using linear elastic material properties. All interfaces, including the augment-bone interface (representing full bony ingrowth construct) were modeled using bonded contact. The inferior surface of the bone analogue was constrained. Linear static analyses were performed and peak von mises stress predicted in the tibial augments was compared between activities. RESULTS. Deep knee bend resulted in 31% higher stresses in the tibial augments than for walking. High von mises stresses were mostly predicted at the superior/posterior aspect of the internal side of the augment and in the corners of the cutouts. Figure 3 presents the von mises stresses in the tibial augments for both loading scenarios. DISCUSSION. This study revealed that the 45% increased posterior compressive load associated with deep knee bend is a more significant factor than the moment applied to the post during walking gait for a hyperextended knee, when considering the stress in bone filler augments in revision TKA. The stress in the augments can depend on multiple factors and the proposed FEA method can be used to compare stresses in different porous material bone fillers to determine worst case for assessing its strength


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 134 - 134
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION. 3D preoperative planning software for anatomic total shoulder arthroplasty (ATSA) provides surgeons with increased ability to visualize complex joint relationships and deformities. Interestingly, the advent of such software has seemed to create less of a consensus on the optimal way to plan an ATSA rather than more. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current ATSA implant selection and placement. METHODS. 172 ASES members completed an 18-question survey on their thought process for how they select and place an ATSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement. RESULTS. 70 surgeons were grouped into the LV cohort, and 102 surgeons were grouped into the HV cohort. 46.1% of surgeons in the HV cohort reported using a preoperative planning software for the majority of cases vs. 41.4% in the LV cohort, 48% of surgeons in the HV cohort reported seldom use vs. 24.3% in the LV cohort, and 5.9% of surgeons in the HV cohort reported no use vs. 34.3% in the LV cohort (Figure 1). When questioned on what percentage of ATSA cases do surgeons use augmented glenoid implants, 20.6% in the HV cohort responded never using augments vs. 30% in the LV cohort, 39.2% responded using augments <15% of the time in the HV cohort vs. 34.3% in the LV cohort, 26.5% responded using augments between 15–45% of the time in the HV cohort vs. 28.6% in the LV cohort, and 13.7% responded using augments >45% of the time in the HV cohort vs. 7.2% in the LV cohort (Figure 2). When asked what the maximum allowable residual retroversion for an ATSA glenoid implant is, surgeons answered 0–5° 6.9% of the time in the HV cohort vs. 4.3% in the LV cohort, 6–9° 35.6% of the time in the HV cohort vs. 50% in the LV cohort, 10–12° 34.7% of the time in the HV cohort vs. 32.9% in the LV cohort, 13–15° 10.9% of the time in the HV cohort vs. 8.6% in the LV cohort, and lastly >16° 11.9% of the time in the HV cohort vs. 4.3% in the LV cohort (Figure 3). CONCLUSION. Research suggests ATSA glenoid implants may be less forgiving of malalignment than reverse shoulder glenoid implants, but the contrasting survey results in this study reveal that a consensus in optimal placement has yet to be reached. Interestingly, even though HV use more augmented glenoid components than LV surgeons, HV surgeons are more accepting of residual glenoid component retroversion than LV surgeons. Despite these differences, there is no way to prove the optimal implant selection and placement without long-term clinical outcomes. For any figures or tables, please contact the authors directly


Bone & Joint Open
Vol. 2, Issue 11 | Pages 926 - 931
9 Nov 2021
Houdek MT Wyles CC Smith JH Terzic A Behfar A Sierra RJ

Aims. Bone marrow-derived mesenchymal stem cells obtained from bone marrow aspirate concentrate (BMAC) with platelet-rich plasma (PRP), has been used as an adjuvant to hip decompression. Early results have shown promise for hip preservation in patients with osteonecrosis (ON) of the femoral head. The purpose of the current study is to examine the mid-term outcome of this treatment in patients with precollapse corticosteroid-induced ON of the femoral head. Methods. In all, 22 patients (35 hips; 11 males and 11 females) with precollapse corticosteroid-induced ON of the femoral head underwent hip decompression combined with BMAC and PRP. Mean age and BMI were 43 years (SD 12) and 31 kg/m² (SD 6), respectively, at the time of surgery. Survivorship free from femoral head collapse and total hip arthroplasty (THA) and risk factors for progression were evaluated at minimum five-years of clinical follow-up with a mean follow-up of seven years (5 to 8). Results. Survivorship free from femoral head collapse and THA for any reason was 84% and 67% at seven years postoperatively, respectively. Risk factors for conversion to THA included a high preoperative modified Kerboul angle (grade 3 or 4) based on preoperative MRI (hazard ratio (HR) 3.96; p = 0.047) and corticosteroid use at the time of decompression (HR 4.15; p = 0.039). The seven-year survivorship for patients with grade 1 or 2 Kerboul angles for conversion to THA for articular collapse, and THA for any reason, were 96% and 72%, respectively, versus THA for articular collapse and THA for any reason in patients with grade 3 or 4 Kerboul angles of 40% (p = 0.003) and 40% (p = 0.032). Conclusion. At seven years, hip decompression augmented with BMAC and PRP provided a 67% survivorship free from THA in patients with corticosteroid-induced ON. Ideal candidates for this procedure are patients with low preoperative Kerboul angles and can stop corticosteroid treatment prior to decompression. Cite this article: Bone Jt Open 2021;2(11):926–931


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 12 - 12
1 May 2019
Throckmorton T
Full Access

Reverse total shoulder arthroplasty (RTSA) has a proven track record as an effective treatment for a variety of rotator cuff deficient conditions. However, glenoid erosion associated with the arthritic component of these conditions can present a challenge for the shoulder arthroplasty surgeon. Options for treatment of glenoid wear include partial reaming with incomplete baseplate seating, bony augmentation using structural or impaction grafting techniques, and augmented baseplates. Augmented components have the advantage of accommodating glenoid deformity with a durable material and also ream less subchondral bone; both of which may offer an advantage over traditional bone grafting. Biomechanical and early clinical studies of augmented glenoid baseplates suggest they are a reasonable treatment option, though posteriorly augmented baseplates have shown better performance than superiorly augmented implants. However, there are no mid- or late-term studies comparing augmented baseplates to bone grafting or partial reaming. We present a live surgical demonstration of RTSA for a patient with advanced glenoid erosion being treated with an augmented glenoid baseplate that can be dialed in the direction of any deformity (superior, posterior, etc.). This versatility allows the surgeon to place the augment in any direction and is not confined to the traditional concepts of glenoid wear in a single vector. Clearly, longer term follow up studies are needed to determine the ultimate effectiveness of these devices in treating glenoid deformity in RTSA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 119 - 119
1 Nov 2021
Facchini A Troiano E Saviori M Meglio MD Ghezzi R Mondanelli N Giannotti S
Full Access

Introduction and Objective. The aim of this study was to evaluate whether CT-based pre-operative planning, integrated with intra-operative navigation could improve glenoid baseplate fixation and positioning by increasing screw length, reducing number of screws required to obtain fixation and increasing the use of augmented baseplate to gain the desired positioning. Reverse total shoulder arthroplasty (RSA) successfully restores shoulder function in different conditions. Glenoid baseplate fixation and positioning seem to be the most important factors influencing RSA survival. When scapular anatomy is distorted (primitive or secondary), optimal baseplate positioning and secure screw purchase can be challenging. Materials and Methods. Twenty patients who underwent navigated RSA (oct 2018 and feb 2019) were compared retrospectively with twenty patients operated on with a conventional technique. All the procedures were performed by the same surgeon, using the same implant in cases of eccentric osteoarthritis or complete cuff tear. Exclusion criteria were: other diagnosis as proximal humeral fractures, post-traumatic OA previously treated operatively with hardware retention, revision shoulder arthroplasty. Results. The NAV procedure required mean 11 (range 7–16) minutes more to performed than the conventional procedure. Mean screw length was significantly longer in the navigation group (35.5+4.4 mm vs 29.9+3.6 mm; p . .001). Significant higher rate of optimal fixation using 2 screws only (17 vs 3 cases, p . .019) and higher rate of augmented baseplate usage (13 vs 4 cases, p . .009) was also present in the navigation group. Signficant difference there is all in function outcomes, DASH score is 15.7 vs 29.4 and constant scale 78.1 vs 69.8. Conclusions. The glenoid component positioning in RSA is crucial to prevent failure, loosening and biomechanical mismatch, coverage by the baseplate of the glenoid surface, version, inclination and offset are all essential for implant survival. This study showed how useful 3D CT-based planning helps in identifying the best position of the metaglena and the usefulness of receiving directly in the operation theater real-time feedback on the change in position. This study shows promising results, suggesting that improved baseplate and screw positioning and fixation is possible when computer-assisted implantation is used in RSA comparing to a conventional procedure


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. Results. Mean initial stiffness (N/mm) was 581.3 (. sd. 239.7) for the gliding plate, 631.5 (. sd. 160.0) for the PHILOS and 440.2 (. sd. 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; . sd. 1.9), PHILOS (1.2; . sd. 0.6) and gliding augmented plate (1.7; . sd. 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; . sd. 2.85), PHILOS (1.30; . sd. 0.44) and gliding augmented plate (2.83; . sd. 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (. sd. 3687) for the gliding plate, 13948 (. sd. 1295) for PHILOS and 13189 (. sd. 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). Conclusion. Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in comparison with fixation using a standard PHILOS plate. Based on the finding of telescoping of screws, however, it may represent a valid approach for further investigations into how to avoid the cut-out of screws. Cite this article: Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422–429. DOI: 10.1302/2046-3758.76.BJR-2017-0356.R1


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1479 - 1488
1 Dec 2019
Laverdière C Corban J Khoury J Ge SM Schupbach J Harvey EJ Reindl R Martineau PA

Aims. Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. Materials and Methods. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers. Results. A total of 41 publications were included after screening. Applications were divided by subspecialty: spine (n = 15), trauma (n = 16), arthroplasty (n = 3), oncology (n = 3), and sports (n = 4). Out of these, 12 were clinical in nature. AR-based technologies have a wide variety of applications, including direct visualization of radiological images by overlaying them on the patient and intraoperative guidance using preoperative plans projected onto real anatomy, enabling hands-free real-time access to operating room resources, and promoting telemedicine and education. Conclusion. There is an increasing interest in AR among orthopaedic surgeons. Although studies show similar or better outcomes with AR compared with traditional techniques, many challenges need to be addressed before this technology is ready for widespread use. Cite this article: Bone Joint J 2019;101-B:1479–1488


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 95 - 95
2 Jan 2024
Gjerde C
Full Access

The aim of the ongoing projects was to demonstrate the efficacy of autologous bone marrow derived stem cells (MSC) combined with biomaterial to induced new bone formation in a randomized multicenter controlled clinical trial. Patients with a need for bone reconstruction of residual edentulous ridges in both the mandible and maxilla due to bone defects with a vertical loss of alveolar bone volume and/or knife edge ridges (≤ than 4,5 mm) unable to provide adequate primary stabilization for dental implants were included in the clinical study. Autologous bone marrow MSC were expanded, loaded on BCP and used to augment the alveolar ridges. After five months bone biopsies were harvested at the implant position site and implants were installed in the regenerated bone. The implants were loaded after 8–12 weeks. Safety, efficacy, quality of life and success/survival were assessed. Five clinical centers, 4 different countries participated. Bone grafts harvested from the ramus of the mandibles were used as control in the projects


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 81 - 81
1 Apr 2019
Navarro S Ramkumar P Bouvier J Kwon A
Full Access

BACKGROUND. Telerehabilitation has been shown to both promote effective recovery after shoulder arthroplasty and may improve adherence to treatment. Such systems require demonstration of feasibility, ease of use, efficacy, patient and clinician satisfaction, and overall cost of care, and much of this data has yet to be provided. Few augmented reality rehabilitation approaches have been developed to date. Evidence suggests augmented reality rehabilitation may be equivalent to conventional methods for adherence, improvement of function, and relief of pain seen in these musculoskeletal conditions. We proposed that the development of an augmented reality rehabilitation platform during the pre and postoperative period (including post-shoulder arthroplasty) could be used to track patient activity and range of motion as well as promote recovery. METHODS. A prototype augmented reality platform equipped with a motion sensor system optimised for the upper arm was developed to be used to validate 4 arcs of shoulder motion and complete directed upper arm exercises designed for post-shoulder arthroplasty rehabilitation was built and tested. This system combined augmented reality instructions and motion tracking to follow patients over the course of their therapy, along with a telehealth patient-clinician interface. FINDINGS. The augmented reality platform was tested to validate shoulder range of motion examination similar to that of standard goniometer measurements. Healthy test subjects without shoulder pain or prior shoulder surgery performed the arcs of motion for 5 repetitions as part of a home therapy program. Each motion was measured with angular measurements as a proof of concept with high degree precision (less than 5 degrees). Remote patient-clinician interface testing was also conducted along with a clinician established therapy plan. DISCUSSION. Augmented reality systems that track patients' complex movements, including clinical shoulder range of motion, suggest the promising future of telerehabilitation in arthroplasty, particularly in telemonitoring before and after surgery. As this technology continues to gain acceptance, further studies that evaluate the outcomes of augmented reality rehabilitation for long-term follow-up are needed


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 20 - 20
1 Aug 2018
Ohashi H Yo H Ikawa T Minami Y Teraoka T
Full Access

Reconstruction of massive acetabular bone defects in primary and revision THA is challenging for reconstructive joint surgeons. The use of porous metal augments is one of the options. The advantages of porous metal augments are easy to use, modularity and lack of resorption. We investigated the radiological results of porous metal augments used for massive acetabular bone defects in primary and revision THA. Forty-one hips in forty patients had porous metal augments between 2011 and 2016. Thirty of the procedures were revision arthroplasties and 11 were primary procedures (Crowe type III in 5 hips, Crowe type IV in 3, septic hip sequalae in 2 and RA in one). Four of the revisions were second-stage reimplantation after infection. The Paprosky classification for revision was 2B in 4 hips, 2C in one, 3A in 3 and 3B in 22. Regenerex augments were used in 39 hips and trabecular metal augments were used in 2. Thirty-six cups were cemented and 5 cups were uncemented. Mean follow-up was 37.6 months (range, 1–82). Radiographic findings of osteointegration between host bone and the porous metal augments were assessed. The presence or absence of radiolucent lines between cement or cup/host bone and augment/host bone interface was noted. Two revisions were performed due to infection, one month and 66 months after operation. The other implants were stable without any complications. Osteointegration between host bone and the porous metal augments were recognized in 36 hips. Radiolucent lines between cement/host bone interface, less than 1 mm in width, were visualized in 2 hips. Porous metal augments are convenient and our short-term results showed excellent radiological results for massive acetabular bone defects in primary and revision THA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 131 - 131
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION. The advent of CT based 3D preoperative planning software for reverse total shoulder arthroplasty (RTSA) provides surgeons with more data than ever before to prepare for a case. Interestingly, as the usage of such software has increased, further questions have appeared over the optimal way to plan and place a glenoid implant for RTSA. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current RTSA implant selection and placement. METHODS. 172 ASES members completed an 18-question survey on their thought process for how they select and place a RTSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement. RESULTS. 70 surgeons were grouped into the LV cohort, and 102 surgeons were grouped into the HV cohort. 46.1% of surgeons in the HV cohort reported using a preoperative planning software for the majority of cases, 48% reported seldom use, and 5.9% reported no use. In the LV cohort, 41.4% reported use for the majority of cases, 24.3% reported seldom use, and 34.3% reported no use (Figure 1). When questioned on what percentage of RTSA cases do surgeons use augmented glenoid implants, 26.7% in the HV cohort responded never using augments vs. 32.4% in the LV cohort, 32.7% responded using augments <15% of the time in the HV cohort vs. 30.9% in the LV cohort, 26.7% responded using augments between 15–45% of the time in the HV cohort vs. 27.9% in the LV cohort, and 13.8% responded using augments >45% of the time in the HV cohort vs. 8.8% in the LV cohort (Figure 2). When asked what the maximum allowable superior inclination for a RTSA glenoid implant is, surgeons answered 10° 20.6% of the time in the HV cohort vs. 30% in the LV cohort, 5° 18.6% of the time in the HV cohort vs. 25.7% in the LV cohort, 0° 38.2% of the time in the HV cohort vs. 25.7% in the LV cohort, and no fixed degree 22.5% of the time in the HV cohort vs. 18.6% in the LV cohort (Figure 3). CONCLUSION. The results of this study show that even within a group of highly trained surgeons, there are widely varying opinions on how to plan the optimal RTSA case. Variation between high and low volume surgeons reveals even greater differences, suggesting that experience affects thought pattern. Despite these differences, there is no way to prove the optimal implant selection and placement without consistent data collection and long-term clinical outcomes. Machine learning on large preoperative planning databases combined with clinical outcomes data may provide further clarity on optimal implant placement and selection. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 32 - 32
2 Jan 2024
Traweger A
Full Access

Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff tendon repair by modulating local inflammation and reduce fibrotic scarring. In another approach, we investigated if the local delivery of the tendon ECM protein SPARC, which we previously demonstrated to be essential for tendon maturation and tissue homeostasis, has the potential to enhance tendon healing. Finally, I will present results demonstrating the utility of nanoparticle-delivered, chemically modified mRNAs (cmRNA) to improve tendon repair


Abstract. Background. Extracorporeal radiation therapy (ECRT) has been reported as an oncologically safe and effective reconstruction technique for limb salvage in diaphyseal sarcomas with promising functional results. Factors affecting the ECRT graft-host bone incorporation have not been fully investigated. Methods. In our series of 51 patients of primary bone tumors treated with ECRT, we improvised this technique by using a modified V-shaped osteotomy, additional plates and intra-medullary fibula across the diaphyseal osteotomy in an attempt to increase the stability of fixation, augment graft strength and enhance union at the osteotomy sites. We analyzed our patients for various factors that affected union time and union rate at the osteotomy sites. Results. On univariate analysis, age <20 years, metaphyseal osteotomy site, V-shaped diaphyseal osteotomy, extramedullary plate fixation and use of additional plate at diaphyseal ostetomy had a significantly faster time to union while gender, tumor type, resection length, chemotherapy and use of intra-medullary fibula did not influence union time. In multivariate analysis, metaphyseal ostoeotomy, V-shaped diaphyseal osteotomy and use of additional plate at diaphyseal ostetomy were the independent factors with favourable time to union. Although the rate of union was higher with V-shaped diaphyseal osteotomy and use of additional plate and intra-medullary fibula at diaphyseal ostetomy, this difference could not be established statistically. None of the analyzed factors apparently affected the union rate in univariate analysis. Conclusion. Judicious choice of osteosynthesis and augmentation of ECRT graft can enhance incorporation with reduced complications and good functional outcome


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario. Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters. Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 24 - 24
7 Aug 2023
Myers P Goldberg M Davies P
Full Access

Abstract. Introduction. Augmentation of meniscus repairs with fibrin clot may enhance the healing capacity. Pulling the clot into the tear with a suture ensures that it stays in position. This paper aims to assess the outcome of this technique. Methods. 52 patients over 4 years undergoing suture repair of a meniscus tear with blood clot augmentation were collected from a prospective database. Follow up included outcome scores and a questionnaire. Failure was defined as pain or further surgery secondary to meniscal pathology. Results. There were 32 males and 20 females, mean age of 35 (14–70). The medial meniscus was repaired in 32 knees and the lateral in 20. Complete radial tears were the most common type. Only 2% of tears were in the red-red zone. Follow-up ranged from 12 months to 7 years. Only 1 patient is known to have come to subsequent arthroscopy. Lysholm scores improved from 53.97 (SD 18.14) to 92.08 (SD 8.97), Oxford Knee Scores from 29.84 (SD 9.65) to 45.79 (SD 2.66), KOOS pain scores from 61.49 (SD 22.76) to 93.54 (SD 8.06) and Tegner scores from 4.56 (SD 3.35) to 6.05 (SD 2.41). Conclusions. Pulling a fibrin blood clot into a meniscus tear with a suture ensures that the clot remains in place while the meniscus is repaired. Patients have shown excellent outcomes with 98% survivorship at 45 months. This is a reliable technique for augmenting meniscus repairs especially for tears which otherwise may not have been repaired


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 5 - 5
10 Jun 2024
Gomaa A Heeran N Roper L Airey G Gangadharan R Mason L Bond A
Full Access

Introduction. Fibula shortening with an intact anterior tibiofibular ligament (ATFL) and medial ligament instability causes lateral translation of the talus. Our hypothesis was that the interaction of the AITFL tubercle of the fibular with the tibial incisura would propagate lateral translation due to the size differential. Aim. To assess what degree of shortening of the fibular would cause the lateral translation of the talus. Methodology. Twelve cadaveric ankle specimens were dissected removing all soft tissue except for ligaments. They were fixed on a specially-designed platform within an augmented ankle cage allowing tibial fixation and free movement of the talus. The fibula was progressively shortened in 5mm increments until complete ankle dislocation. The medial clear space was measured with each increment of shortening. Results. The larger AITFL tubercle interaction with the smaller tibial incisura caused a significant increase in lateral translation of the talus. This occurred in most ankles between 5–10mm of fibular shortening. The medial clear space widened following 5mm of shortening in 5 specimens (mean=2.0725, SD=±2.5338). All 12 specimens experienced widening by 10mm fibula shortening (Mean=7.2133mm, SD=±2.2061). All specimens reached complete dislocation by 35mm fibula shortening. Results of ANOVA analysis found the data statistically significant (p<0.0001). Conclusion. This study shows that shortening of the fibula causes a significant lateral translation of the talus provided the ATFL remains intact. Furthermore, the interaction of the fibula notch with the ATFL tubercle of the tibia appears to cause a disproportionate widening of the medial clear space due to its differential in size. Knowledge of the extent of fibula shortening can guide further intervention when presented with a patient experiencing medial clear space widening following treatment of an ankle fracture


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 13 - 13
16 May 2024
Lambert L Davies M Mangwani J Molloy A Mason L
Full Access

Introduction. Anatomic reduction of talar body fractures is critical in restoring congruency to the talocrural joint. Previous studies have indicated a maximum of 25% talar body exposure without malleolar osteotomy. The aim of this study was to investigate the percentage talar body exposure when using the lateral transligamentous approach. Methods. The lateral transligamentous approach to the talus was undertaken in 10 fresh frozen cadaveric specimens by surgeons inexperienced in the approach, following demonstration of the technique. An incision was made on the anterolateral aspect of the ankle augmented by the removal of the anterior talofibular ligament (ATFL) and the calcaneofibular ligament (CFL) from their fibular insertions. A bone lever was then placed behind the lateral aspect of the talus and levered forward with the foot in equinus and inversion. The talus was disarticulated and high resolution images were taken of the talar dome surface. The images were overlain with a reproducible nine-grid division. Accessibility to each zone within the grid with a perpendicular surgical blade was documented. ImageJ software was used to calculate the surface area exposed with each approach. Results. The mean percentage area of talar dome available through the transligamentous approach was 77.3 % (95% confidence interval 73.3, 81.3). In all specimens the complete lateral talar process was accessible, along with the lateral and dorsomedial aspect of the talar neck. This approach gives complete access to Zones 1,2, 3,5 & 6 with partial access to Zones 4,8 & 9. Conclusion. The lateral transligamentous approach to the talus provides significantly greater access to the talar dome as compared to standard approaches. The residual surface area that is inaccessible with this approach is predominantly within Zone 4 and Zone 7, the posteromedial corner


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 83 - 83
10 Feb 2023
Lee H Lewis D Balogh Z
Full Access

Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for both acute fixation and revisions. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles


Background. Osteopathy has been shown to be effective in the management of chronic low back pain. Guidelines recommend biopsychosocial care for chronic, complex musculoskeletal conditions, including non-specific low back pain but there is a lack of evidence comparing standard osteopathic care, which has traditionally been based on dated and disputed biomechanical theories of dysfunction, with more contemporary biopsychosocial approaches. Methods and results. A multiple baseline single case experimental design trial with 11 UK osteopaths and 60 patients is currently assessing effectiveness of osteopathic treatment for patients with non-specific low back pain of more than 12 weeks’ duration. Patients are randomised to early, middle, or late treatment start dates to increase the validity of inferences about the effects of treatment. Osteopaths have participated in one course on the study protocol and processes pre-participation and will take an e-learning course on the biopsychosocial management of patients with low back pain after the first patient recruitment stage. Statistical analysis will assess the degree and rate of change between baseline, intervention and follow-up periods, and whether differences in effect are observed after the osteopaths have completed the biopsychosocial patient management training course. Primary outcomes will be the Numeric Pain Rating and Patient Specific Function Scales, measured daily at baseline and for 6 weeks during the intervention stage, and weekly or fortnightly during a 12-week follow-up period. Conclusion. This experimental design will offer osteopaths in practice the opportunity to engage in research evaluating the effectiveness of osteopathic care and the influence of a training programme to augment biopsychosocial osteopathic care. Study registration: . https://clinicaltrials.gov/ct2/show/NCT05120921. Sources of funding: The Osteopathic Foundation. Conflict of interest: The authors declare no competing interests. Previous publication of work: This protocol is under review with a peer-reviewed journal


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 8 - 8
7 Aug 2023
Kaka A Shah A Yunus A Patel A Patel A
Full Access

Abstract. Introduction. Challenges in surgical training have led to the exploration of technologies such as augmented reality (AR), which present novel approaches to teaching orthopaedic procedures to medical students. The aim of this double-blinded randomised-controlled trial was to compare the validity and training effect of AR to traditional teaching on medical students’ understanding of total knee arthroplasty (TKA). Methodology. Twenty medical students from 7 UK universities were randomised equally to either intervention or control groups. The control received a consultant-led teaching session and the intervention received training via Microsoft HoloLens, where surgeons were able to project virtual information over physical objects. Participants completed written knowledge and practical exams which were assessed by 2 orthopaedic consultants. Training superiority was established via 4 quantitative outcome measures: OSATS scores, a checklist of TKA-specific steps, procedural time, and written exam scores. Qualitative feedback was evaluated using a 5-point Likert scale. Results. AR training was superior in teaching basic technical proficiency and understanding of TKA, with the intervention group significantly outperforming the control group in 3 metrics [OSATS (38.6%, p=0.021), checklist (33%, p=0.011) and written exam (54.5%, p=0.001)]. Procedural time was equivalent between cohorts (p=0.082). AR was rated as significantly more enjoyable (p=0.044), realistic (p=0.003), easy to understand (p=0.040), and proficient in teaching (p=0.02). Conclusion. In this adequately powered, double-blinded randomised-controlled trial, AR training demonstrated substantially improved translational technical skills and knowledge needed to understand TKA over traditional learning in medical students. Additionally, the results showed face, content, and transfer validity for AR in surgical training


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 39 - 39
2 Jan 2024
Pastor T Cattaneo E Pastor T Gueorguiev B Windolf M Buschbaum J
Full Access

Freehand distal interlocking of intramedullary nails remains a challenging task. If not performed correctly it can be a time consuming and radiation expensive procedure. Recently, the AO Research Institute developed a new training device for Digitally Enhanced Hands-on Surgical Training (DEHST) that features practical skills training augmented with digital technologies, potentially improving surgical skills needed for distal interlocking. Aim of the study: To evaluate weather training with DEHST enhances the performance of novices without surgical experience in free-hand distal nail interlocking compared to a non-trained group of novices. 20 novices were assigned in two groups and performed distal interlocking of a tibia nail in an artificial bone model. Group 1: DEHST trained novices (virtual locking of five nail holes during one hour of training). Group 2: untrained novices without DEHST training. Time, number of x-rays, nail hole roundness, critical events and success rates were compared between the groups. Time to complete the task (sec.) and x-ray exposure (µGcm2) were significantly lower in Group1 414.7 (290–615) and 17.8 (9.8–26.4) compared to Group2 623.4 (339–1215) and 32.6 (16.1–55.3); p=0.041 and 0.003. Perfect circle roundness (%) was 95.0 (91.1–98.0) in Group 1 and 80.8 (70.1–88.9) in Group 2; p<0.001. In Group 1 90% of the participants achieved successful completion of the task (hit the nail with the drill), whereas only 60% of the participants in group 2 achieved this; p=0.121. Training with DEHST significantly enhances the performance of novices without surgical experience in distal interlocking of intramedullary nails. Besides radiation exposure and operation time the com-plication rate during the operation can be significantly reduced


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 37 - 37
2 May 2024
Green J Malviya A Reed M
Full Access

OpenPredictor, a machine learning-enabled clinical decision aid, has been developed to manage backlogs in elective surgeries. It aims to optimise the use of high volume, low complexity surgical pathways by accurately stratifying patient risk, thereby facilitating the allocation of patients to the most suitable surgical sites. The tool augments elective surgical pathways by providing automated secondary opinions for perioperative risk assessments, enhancing decision-making. Its primary application is in elective sites utilising lighter pre-assessment methods, identifying patients with minimal complication risks and those high-risk individuals who may benefit from early pre-assessment. The Phase 1 clinical evaluation of OpenPredictor entailed a prospective analysis of 156 patient records from elective hip and knee joint replacement surgeries. Using a polynomial logistic regression model, patients were categorised into high, moderate, and low-risk groups. This categorisation incorporated data from various sources, including patient demographics, co-morbidities, blood tests, and overall health status. In identifying patients at risk of postoperative complications, OpenPredictor demonstrated parity with consultant-led preoperative assessments. It accurately flagged 70% of patients who later experienced complications as moderate or high risk. The tool's efficiency in risk prediction was evidenced by its balanced accuracy (75.6%), sensitivity (70% with a 95% confidence interval of 62.05% to 76.91%), and a high negative predictive value (96.7%). OpenPredictor presents a scalable and consistent solution for managing elective surgery pathways, comparable in performance to secondary consultant opinions. Its integration into pre-assessment workflows assists in efficient patient categorisation, reduces late surgery cancellations, and optimises resource allocation. The Phase 1 evaluation of OpenPredictor underscores its potential for broader clinical application and highlights the need for ongoing data refinement and system integration to enhance its performance


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 6 - 6
8 May 2024
Miller D Senthi S Winson I
Full Access

Background. Total ankle replacements (TARs) are becoming increasingly more common in the treatment of end stage ankle arthritis. As a consequence, more patients are presenting with the complex situation of the failing TAR. The aim of this study was to present our case series of isolated ankle fusions post failed TAR using a spinal cage construct and anterior plating technique. Methods. A retrospective review of prospectively collected data was performed for 6 patients that had isolated ankle fusions performed for failed TAR. These were performed by a single surgeon (IW) between March 2012 and October 2014. The procedure was performed using a Spinal Cage construct and grafting in the joint defect and anterior plating. Our primary outcome measure was clinical and radiographic union at 1 year. Union was defined as clinical union and no evidence of radiographic hardware loosening or persistent joint lucent line at 1 year. Results. The mean follow-up was 37.3 months (SD 13.2). Union was achieved in 5 of the 6 patients (83%). One patient had a non-union that required revision fusion incorporating the talonavicular joint that successfully went on to unite across both joints. Another patient had radiographic features of non-union but was clinically united and asymptomatic and one required revision surgery for a bulky symptomatic lateral malleolus with fused ankle joint. Conclusion. The failing TAR presents a complex clinical situation. After removal of the implant there is often a large defect which if compressed leads to a leg length discrepancy and if filled with augment can increase the risk of non-union. Multiple methods have been described for revision, with many advocating fusion of both the ankle joint and subtalar joint. We present our case series using a spinal cage and anterior plating that allows preservation of the subtalar joint and a high rate of union


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 55 - 55
11 Apr 2023
Raina D Markeviciute V Arvidsson L Törnquist E Stravinskas M Kok J Jacobson I Liu Y Tengattini A Sezgin E Vater C Zwingenberger S Isaksson H Tägil M Tarasevicius S Lidgren L
Full Access

Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for hip fracture fixation. As a proof-of-concept, the method was then verified in donated femoral heads and in patients with osteoporosis undergoing hip fracture fixation. We show that placing HA particles around a stainless-steel screw in-vivo, systemically administered bisphosphonates could be targeted towards the implant, yielding significantly higher peri-implant bone formation compared to un-augmented controls. In the sawbones model, CaS/HA based lag-screw augmentation led to significant increase (up to 4 times) in peak extraction force with CaS/HA performing at par with PMMA. Micro-CT imaging of the CaS/HA augmented lag-screws in cadaver femoral heads verified that the entire length of the lag-screw threads and the surrounding bone was covered with the CaS/HA material. X-ray images from fracture fixation surgery indicated that the CaS/HA material could be applied at the lag-screw-bone interface without exerting any additional pressure or risk of venous vascular leakage.: We present a new method for augmentation of lag-screws in fragile bone. It is envisaged that this methodcould potentially reduce the risk of fracture fixation failure especially when HA seeking “bone active” drugs are used systemically


Bone & Joint Open
Vol. 2, Issue 8 | Pages 638 - 645
1 Aug 2021
Garner AJ Edwards TC Liddle AD Jones GG Cobb JP

Aims. Joint registries classify all further arthroplasty procedures to a knee with an existing partial arthroplasty as revision surgery, regardless of the actual procedure performed. Relatively minor procedures, including bearing exchanges, are classified in the same way as major operations requiring augments and stems. A new classification system is proposed to acknowledge and describe the detail of these procedures, which has implications for risk, recovery, and health economics. Methods. Classification categories were proposed by a surgical consensus group, then ranked by patients, according to perceived invasiveness and implications for recovery. In round one, 26 revision cases were classified by the consensus group. Results were tested for inter-rater reliability. In round two, four additional cases were added for clarity. Round three repeated the survey one month later, subject to inter- and intrarater reliability testing. In round four, five additional expert partial knee arthroplasty surgeons were asked to classify the 30 cases according to the proposed revision partial knee classification (RPKC) system. Results. Four classes were proposed: PR1, where no bone-implant interfaces are affected; PR2, where surgery does not include conversion to total knee arthroplasty, for example, a second partial arthroplasty to a native compartment; PR3, when a standard primary total knee prosthesis is used; and PR4 when revision components are necessary. Round one resulted in 92% inter-rater agreement (Kendall’s W 0.97; p < 0.005), rising to 93% in round two (Kendall’s W 0.98; p < 0.001). Round three demonstrated 97% agreement (Kendall’s W 0.98; p < 0.001), with high intra-rater reliability (interclass correlation coefficient (ICC) 0.99; 95% confidence interval 0.98 to 0.99). Round four resulted in 80% agreement (Kendall’s W 0.92; p < 0.001). Conclusion. The RPKC system accounts for all procedures which may be appropriate following partial knee arthroplasty. It has been shown to be reliable, repeatable and pragmatic. The implications for patient care and health economics are discussed. Cite this article: Bone Jt Open 2021;2(8):638–645


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 68 - 68
10 Feb 2023
Zaidi F Bolam S Yeung T Besier T Hanlon M Munro J Monk A
Full Access

Patient-reported outcome measures (PROMs) have failed to highlight differences in function or outcome when comparing knee replacement designs and implantation techniques. Ankle-worn inertial measurement units (IMUs) can be used to remotely measure and monitor the bi-lateral impact load of patients, augmenting traditional PROMs with objective data. The aim of this study was to compare IMU-based impact loads with PROMs in patients who had undergone conventional total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA), and robotic-assisted TKA (RA-TKA). 77 patients undergoing primary knee arthroplasty (29 RA-TKA, 37 TKA, and 11 UKA) for osteoarthritis were prospectively enrolled. Remote patient monitoring was performed pre-operatively, then weekly from post-operative weeks two to six using ankle-worn IMUs and PROMs. IMU-based outcomes included: cumulative impact load, bone stimulus, and impact load asymmetry. PROMs scores included: Oxford Knee Score (OKS), EuroQol Five-dimension with EuroQol visual analogue scale, and the Forgotten Joint Score. On average, patients showed improved impact load asymmetry by 67% (p=0.001), bone stimulus by 41% (p<0.001), and cumulative impact load by 121% (p=0.035) between post-operative week two and six. Differences in IMU-based outcomes were observed in the initial six weeks post-operatively between surgical procedures. The mean change scores for OKS were 7.5 (RA-TKA), 11.4 (TKA), and 11.2 (UKA) over the early post-operative period (p=0.144). Improvements in OKS were consistent with IMU outcomes in the RA-TKA group, however, conventional TKA and UKA groups did not reflect the same trend in improvement as OKS, demonstrating a functional decline. Our data illustrate that PROMs do not necessarily align with patient function, with some patients reporting good PROMs, yet show a decline in cumulative impact load or load asymmetry. These data also provide evidence for a difference in the functional outcome of TKA and UKA patients that might be overlooked by using PROMs alone


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 29 - 29
4 Apr 2023
Bolam S Konar S Zhu M Workman J Lim K Woodfield T Monk P Coleman B Cornish J Munro J Musson D
Full Access

Re-rupture rates after rotator cuff repair remain high because of inadequate biological healing at the tendon-bone interface. Single-growth factor therapies to augment healing at the enthesis have so far yielded inconsistent results. An emerging approach is to combine multiple growth factors over a spatiotemporal distribution that mimics normal healing. We propose a novel combination treatment of insulin-like growth factor 1 (IGF-1), transforming growth factor β1 (TGF-β1) and parathyroid hormone (PTH) incorporated into a controlled-release tyraminated poly-vinyl-alcohol hydrogel to improve healing after rotator cuff repair. We aimed to evaluate this growth factor treatment in a rat chronic rotator cuff tear model. A total of 30 male Sprague-Dawley rats underwent unilateral supraspinatus tenotomy. Delayed rotator cuff repairs were then performed after 3 weeks, to allow tendon degeneration that resembles the human clinical scenario. Animals were randomly assigned to: [1] a control group with repair alone; or [2] a treatment group in which the hydrogel was applied at the repair site. All animals were euthanized 12 weeks after rotator cuff surgery and the explanted shoulders were analyzed for biomechanical strength and histological quality of healing at the repair site. In the treatment group had significantly higher stress at failure (73% improvement, P=0.003) and Young's modulus (56% improvement, P=0.028) compared to the control group. Histological assessment revealed improved healing with significantly higher overall histological scores (10.1 of 15 vs 6.55 of 15, P=0.032), and lower inflammation and vascularity. This novel combination growth factor treatment improved the quality of healing and strength of the repaired enthesis in a chronic rotator cuff tear model. Further optimization and tailoring of the growth factors hydrogel is required prior to consideration for clinical use in the treatment of rotator cuff tears. This novel treatment approach holds promise for improving biological healing of this clinically challenging problem


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 9 - 9
4 Apr 2023
Fridberg M Annadatha S Hua Q Jensen T Liu J Kold S Rahbek O Shen M Ghaffari A
Full Access

To detect early signs of infection infrared thermography has been suggested to provide quantitative information. Our vision is to invent a pin site infection thermographic surveillance tool for patients at home. A preliminary step to this goal is the aim of this study, to automate the process of locating the pin and detecting the pin sites in thermal images efficiently, exactly, and reliably for extracting pin site temperatures. A total of 1708 pin sites was investigated with Thermography and augmented by 9 different methods in to totally 10.409 images. The dataset was divided into a training set (n=8325), a validation set (n=1040), and a test set (n=1044) of images. The Pin Detection Model (PDM) was developed as follows: A You Only Look Once (YOLOv5) based object detection model with a Complete Detection Intersection over Union (CDIoU), it was pre-trained and finetuned by the through transfer learning. The basic performance of the YOLOv5 with CDIoU model was compared with other conventional models (FCOS and YOLOv4) for deep and transition learning to improve performance and precision. Maximum Temperature Extraction (MTE) Based on Region of Interest (ROI) for all pin sites was generated by the model. Inference of MTE using PDM with infected and un-infected datasets was investigated. An automatic tool that can identify and annotate pin sites on conventional images using bounding boxes was established. The bounding box was transferred to the infrared image. The PMD algorithm was built on YOLOv5 with CDIoU and has a precision of 0.976. The model offers the pin site detection in 1.8 milliseconds. The thermal data from ROI at the pin site was automatically extracted. These results enable automatic pin site annotation on thermography. The model tracks the correlation between temperature and infection from the detected pin sites and demonstrates it is a promising tool for automatic pin site detection and maximum temperature extraction for further infection studies. Our work for automatic pin site annotation on thermography paves the way for future research on infection assessment using thermography


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 6 - 6
1 May 2019
Jobin C
Full Access

Severe glenoid bone loss in patients with osteoarthritis with intact rotator cuff is associated with posterior glenoid bone loss and posterior humeral subluxation. Management of severe glenoid bone loss during shoulder arthroplasty is controversial and technically challenging and options range from humeral hemiarthroplasty, anatomic shoulder replacement with glenoid bone grafting or augmented glenoid component implantation, to reverse replacement with reaming to correct version or structural bone grafting or metallic augmentation of the bone deficiency. Shoulder replacement with severe glenoid bone loss is technically challenging and characterised by higher rates of complications and revisions. Hemiarthroplasty has limited benefit for pain relief and function especially if eccentric glenoid wear exists. Bone loss with >15 degrees of retroversion likely requires version correction include bone-grafting, augmented glenoid components, or reverse total shoulder replacement. Asymmetric reaming may improve version but is limited to 15 degrees of version correction in order to preserve subchondral bone and glenoid bone vault depth. Bone-grafting of glenoid wear and defects has had mixed results with graft-related complications, periprosthetic radiolucent lines, and glenoid component failure of fixation. Implantation of an augmented wedge or step polyethylene glenoid component improves joint version while preserving subchondral bone, but is technically demanding and with minimal short term clinical follow-up. A Mayo study demonstrated roughly 50% of patients with posteriorly augmented polyethylene had radiolucent lines and 1/3 had posterior subluxation. Another wedge polyethylene design had 66% with bone ingrowth around polyethylene fins at 3 years. Long term outcomes are unknown for these new wedge augmented glenoid components. Reverse shoulder arthroplasty avoids many risks of anatomic replacement glenoid component fixation and stability but is associated with a high complication rate (15%) including neurologic and baseplate loosening and often requires structural bone grafting behind the baseplate with suboptimal outcomes or metallic augmented baseplates with limited evidence and short term outcomes. Reverse replacement with baseplate bone grafting or metal augmentation is technically challenging due to limited native glenoid bone stock available for baseplate component ingrowth and long term fixation. Failure to correct glenoid superior inclination and restore neutral version within 10 degrees increases the risks of reverse baseplate failure of fixation, pull out, and failure of reverse replacement. Reverse baseplate failure rates in patients with severe glenoid bone loss and concomitant glenoid bone grafting range from 5–11%. The minimum native glenoid bony contact with the baseplate is unknown but likely is approximately 1cm of native bone contacting a central ingrowth post and a minority (∼15–25%) of native glenoid contacting the backside of the baseplate. Failure to correct posterior bone loss can lead to retroversion of the baseplate, reduced external rotation, posterior scapular notching, and posteromedial polyethylene wear. In summary, shoulder replacement with severe glenoid bone loss is technically challenging and characterised by higher rates of complication and revision


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 13 - 13
1 May 2021
Davies-Branch NR Oliver WM Davidson EK Duckworth AD Keating JF White TO
Full Access

The aim was to report operative complications, radiographic and patient-reported outcomes following lateral tibial plateau fracture fixation augmented with calcium phosphate cement (CPC). From 2007–2018, 187 patients (median age 57yrs [range 22–88], 63% female [n=118/187]) with a Schatzker II/III fracture were retrospectively identified. There were 103 (55%) ORIF and 84 (45%) percutaneous fixation procedures. Complications and radiographic outcomes were determined from outpatient records and radiographs. Long-term follow-up was via telephone interview. At a median of 6 months (range 0.1–138) postoperatively, complications included superficial peroneal nerve injury (0.5%, n=1/187), infection (6.4%, n=12/187), prominent metalwork (10.2%, n=19/187) and post-traumatic osteoarthritis (PTOA; 5.3%, n=10/187). The median postoperative medial proximal tibial angle was 89o (range 82–107) and posterior proximal tibial angle 82o (range 45–95). Three patients (1.6%) underwent debridement for infection and 27 (14.4%) required metalwork removal. Seven patients (4.2%) underwent total knee replacement for PTOA. Sixty percent of available patients (n=97/163) completed telephone follow-up at a median of 6yrs (range 1–13). The median Oxford Knee Score was 42 (range 3–48), Knee injury and Osteoarthritis Outcome Score 88 (range 10–100), EuroQol 5-Dimension score 0.812 (range −0.349–1.000) and Visual Analogue Scale 75 (range 10–100). There were no significant differences between ORIF and percutaneous fixation in patient-reported outcome (all p>0.05). Fixation augmented with CPC is safe and effective for lateral tibial plateau fractures, with a low complication rate and good long-term knee function and health-related quality of life. Percutaneous fixation offers a viable alternative to ORIF with no detriment to patient-reported outcome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 44 - 44
11 Apr 2023
Medesan P Chen Y Rust P Mearns-Spragg A Paxton J
Full Access

Jellyfish collagens exhibit auspicious perspectives for tissue engineering applications primarily due to their outstanding compatibility with a wide range of cell types, low immunogenicity and biodegradability. Furthermore, derived from a non-mammalian source, jellyfish collagens reduce the risk of disease transmission, minimising therefore the ethical and safety concerns. The current study aims to investigate the potential of 3-dimensional jellyfish collagen sponges (3D-JCS) in promoting bone tissue regeneration. Both qualitative and quantitative analyses were performed in order to assess adhesion and proliferation of MC3T3 cells on 3D-JCL, as well as cell migration and bone-like ECM production. Histological and fluorescent dyes were used to stain mineral deposits (i.e. Alizarin Red S (ARS), Von Kossa, Tetracycline hydrochloride) while images were acquired using optical and confocal microscopy. Qualitative data indicated successful adhesion and proliferation of MC3T3 cells on the 3D-JCS as well as cell migration along with ECM production both on the inner and outer surface of the scaffolds. Moreover, quantitative analyses indicated a four-fold increase of ARS uptake between 2- and 3-dimensional cultures (N=3) as well as an eighteen-fold increase of ARS uptake for the 3D-JCS (N=3) when cultured in osteogenic conditions compared to control. This suggests the augmented osteogenic potential of MC3T3 cells when cultured on 3D-JCS. Nevertheless, the cell-mediated mineral deposition appeared to alter the mechanical properties of the jellyfish collagen sponges that were previously reported to exhibit low mechanical properties (compressive modulus: 1-2 kPa before culture). The biocompatibility, high porosity and pore interconnectivity of jellyfish collagen sponges promoted adhesion and proliferation of MC3T3 cells as well as cell migration and bone-like ECM production. Their unique features recommend the jellyfish collagen sponges as superior biomaterial scaffolds for bone tissue regeneration. Further studies are required to quantify the change in mechanical properties of the cell-seeded scaffolds and confirm their suitability for bone tissue regeneration. We predict that the 3D-JCS will be useful for future studies in both bone and bone-tendon interface regeneration. Acknowledgments. This research has been supported by a Medical Research Scotland Studentship award (ref: -50177-2019) in collaboration with Jellagen Ltd


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 118 - 118
1 Jun 2018
Rodriguez J
Full Access

Bone loss creates a challenge to achieving fixation in revision TKR. Failure to achieve metaphyseal fixation is associated with failure in revision TKR. In the absence of cancellous bone for cement fixation, metaphyseal augments placed without cement have shown promise in achieving fixation. First generation augments were modular solid titanium sleeves attached to a taper at the base of the core implant. The introduction of tantalum with its favorable mechanical qualities markedly increased the utility and utilization of metaphyseal augments, with positive reports. These are either large augments where the bone is prepared with a burr, or later small cones placed with a cannulated broaching technique. Both have solved real problems, the first being limited by the reproducibility of bone preparation, and the second with excellent reproducibility of bone preparation but limited diameters. Other highly porous titanium surfaces have broadened the choices. Modern metaphyseal augments seek to add flexibility and options, specifically the use of offset stems. One tibial augment design features a reamed cone with a matching conical implant. Another option is based on an anatomic cone design with a single ream and a broached technique to optimise endosteal cortical bone contact. With each of these options, the augment can be placed wherever the remaining bone exists for fixation, even down to the metaphyseal-diaphyseal junction, and not limited to the area adjacent to the cut surface of bone. Once independent fixation is achieved, the intramedullary stem is cemented inside of it. Modern femoral augments are designed to sit either in the epiphyseal region, or the metaphysis. Cannulated reaming systems allow for preparation of complex asymmetrical double cone implants at the epiphysis. Metaphyseal implants are designed anatomically to sit deeper in the femoral bone, and can manage larger bony defects. Each system has benefits and compromises, and together they comprise increasingly powerful alternatives to manage extensive bone loss