This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.Aims
Methods
Abstract: The dissatisfaction rate in patients operated with TKR is generally quoted to be around 20% in various registries in patients operated by multiple surgeons. The data of satisfaction rates following a TKR performed by single high volume surgeons is lacking. To study the satisfaction rate and Net Promoter Score (NPS) of consecutively operated TKR patients by a single surgeon with a minimum 1 year follow up.Abstract
Background
Aim
To study and compare the rise of Inflammatory markers post TKR operated by Medial parapatellar approach with tourniquet (MP) and by Subvastus approach used without tourniquet. (SV) 100 patients were operated for a TKR by two experienced Arthroplasty surgeons utilising either the MP approach or the SV approach. (50 knees each). The groups were well matched as regards age, degree of deformity, obesity, pre-op knee scores and co-morbidities. The patients were managed peri-operatively in an identical manner .5 inflammatory markers viz: IL-6, AST, LDH, CRP and ESR were measured pre-operatively and at 12, 24,48 and 72 hours postoperatively. Additionally, the patients' VAS score at these intervals and Morbidity Index was determined.Abstract
Aim
Materials and Methods
With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases. A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).Aims
Methods
With resumption of elective spine surgery services following the first wave of COVID-19 pandemic, we conducted a multi-centre BASS collaborative study to examine the clinical outcomes of surgeries. Prospective data was collected from eight spinal centres in the first month of operating following restoration of elective spine surgery following the first wave. Primary outcomes measures were the 30-day mortality rate and postoperative Covid-19 infection rate. Secondary outcomes analysed were the surgical, medical adverse events and length of inpatient stay.Abstract
Aim
Methods
Patients with metastatic spinal cord compression (MSCC) or unstable spinal lesions warrant early surgical consultation. In multiple myeloma, chemotherapy and radiotherapy have the potential to decompress the spinal canal effectively in the presence of epidural lesions. Mechanical stability conferred by bracing may potentiate intraosseous and extraosseous bone formation, thus increasing spinal stability. This study aims to review the role of non-operative management in myeloma patients with a high degree of spinal instability, in a specialist tertiary centre. Retrospective analysis of a prospectively collected database of 83 patients with unstable myelomatous lesions of the spine, defined by a Spinal Instability Neoplastic Score (SINS) of 13–18. Data collected include patient demographics, systemic treatment, neurological status, radiological presence of cord compression, most unstable vertebral level and presence of intraosseous and extraosseous bone formation. Post-treatment scores were calculated based on follow-up imaging which was carried out at 2 weeks for cord compression and 12 weeks for spinal instability. A paired t-test was used to identify any significant difference between pre- and post-treatment SINS and linear regression was used to assess the association between variables and the change in SINS.Introduction
Methods
Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre. A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications. Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded. This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory clinical and radiographic results. Long term studies are needed to assess the possibility of preservation and regeneration of bone stock.
The exact risk to patients undergoing surgery who develop COVID-19 is not yet fully known. This study aims to provide the current data to allow adequate consent regarding the risks of post-surgery COVID-19 infection and subsequent COVID-19-related mortality. All orthopaedic trauma cases at the Wrightington Wigan and Leigh NHS Foundation Trust from ‘lockdown’ (23 March 2020) to date (15 June 2020) were collated and split into three groups. Adult ambulatory trauma surgeries (upper limb trauma, ankle fracture, tibial plateau fracture) and regional-specific referrals (periprosthetic hip fracture) were performed at a stand-alone elective site that accepted COVID-19-negative patients. Neck of femur fractures (NOFF) and all remaining non-NOFF (paediatric trauma, long bone injury) surgeries were performed at an acute site hospital (mixed green/blue site). Patients were swabbed for COVID-19 before surgery on both sites. Age, sex, nature of surgery, American Society of Anaesthesiologists (ASA) grade, associated comorbidity, length of stay, development of post-surgical COVID-19 infection, and post-surgical COVID-19-related deaths were collected.Aims
Methods
Infections in orthopaedic surgery are costly, debilitating complications. The search for new treatments and prevention strategies has led to the use of antibiotic-filled calcium sulfate (CaS) as a bone void filler that is both safe and effective. The purpose of this study was to examine the available data on the efficacy of this technology. A literature search was performed for studies that evaluated the use of antibiotic-loaded CaS cement in orthopaedics published between inception of the databases to 2017. Selected studies included randomized controlled trials (RCTs) and observational studies published in the English language that met the following criteria: 1) patients underwent an orthopaedic procedure; 2) CaS cement with an antibiotic was used; and 3) at least one of our outcomes were mentioned. Outcomes included resolution of infection, complications related to treatment, subsequent surgeries, overall infection rate, fracture union rate, clinical outcomes, and wound complications. A total of 17 studies were included.Purpose
Methods
A meta-analysis was performed to compare rate of SSI after application of chlorhexidine vs. iodine in total joint arthroplasty. Chlorhexidine had significantly lower odds of SSI. Surgical site infections (SSI) are a significant source of morbidity and mortality. The optimal preoperative skin preparation in lower extremity total joint arthroplasty (TJA) remains debatable between chlorhexidine and iodine-containing solutions. This meta-analysis sought compare SSI rates between chlorhexidine cloth application the night before surgery plus povidone-iodine-alcohol (povidone-iodine) solution at surgery or only povidone-iodine at surgery.Summary
Introduction
To evaluate the clinical and functional outcomes obtained by combination of high-flexion Freedom® Total Knee System (TKS) and mini-subvastus approach in total knee replacement patients. This is a retrospective, observational, real world study conducted at Mumbai in India from 2011 to 2016. All patients who were above the age of 18 and operated for total knee replacement (TKR) with mini-subvastus approach using Freedom (Maxx Medical) by the senior author were included. The Implant survivorship was the survey endpoint; primary endpoint was range of motion (ROM); and secondary endpoints were AKSS (American Knee Society Score) and WOMAC (Western Ontario and McMaster Universities Osteoarthritis) scores collected pre- and post-operatively.Objective
Method
With increasing burden of revision hip arthroplasty, one of the major challenge is the management of bone loss associated with previous multiple surgeries. Proximal femoral replacement (PFR) has already been popularised for tumour surgeries. The inherent advantages of PFR over allograft –prosthesis system, which is the other option for addressing severe bone loss include, early weight bearing and avoidance of non-union and disease transmission. Our study explores PFR as a possible solution for the management of complex hip revisions. Thirty consecutive hips (29 patients) that underwent PFR between January 2009 and December 2015 were reviewed retrospectively for their clinical and radiological outcomes. The Stanmore METS system was used in all these patients. Mean age at the index surgery (PFR) was 72.69 years (range 50–89) with number of previous hip arthroplasties ranging from 1–5. At mean follow up of 32.27 months, there were no peri-prosthetic fractures and no mechanical failure of the implants. Clearance of infection was achieved in 80% of cases. There was 1 early failure due to intra-operative perforation of femoral canal needing further revision and two were revised for deep infection. Instability was noted in 26.7% (8) of the hips, of which, 87.5% (7) needed further revision with constrained sockets. Out of these 8 hips with instability, 5 had pre-operative infection. Deep infection was noted in 20% (6) of the hips, of which, 5 were primarily revised with PFR for septic loosening. However, further surgeries were essential for only 3 patients. One patient has symptomatic aseptic acetabular loosening and 1 had asymptomatic progressive femoral side loosening (lost to follow up). Severe proximal femoral bone loss in complex revision arthroplasties has necessitated the use of PFR prosthesis. Our study supports the fact that PFR is probably a mechanically viable option for complex revisions. Significant numbers of dislocations and infections could be attributed to the poor soft tissue envelope around the hip. Further surgical techniques in the form use of dual mobility cups and silver coated PFR implants need to be explored.
The ideal operative treatment of displaced sub capital femoral fractures in the elderly is controversial. Recently, randomised controlled trials have suggested a better outcome with the use of total hip arthroplasty (THA) to treat displaced intra capsular fractures of the femur for elderly patients in good health. More recently the concept of dual mobility cups is being promoted to avoid dislocations in this cohort of patients. However, overall there is limited evidence to support the choice between different types of arthroplasty. Dislocation remains a main concern with THA, especially when a posterior approach is used. We analysed the outcome of 115 primary THR (112 cements and 3 uncemented) THR using a posterior approach with soft tissue repair in active elderly patients presenting with displaced intra capsular femoral neck fractures. Size 28 mm head was used in 108 and a size 32 mm head in the rest. All surgery was performed by specialist hip surgeons. Satisfactory results were noted in terms of pain control, return to pre-morbid activity and radiological evidence of bone implant osteo-integration. The 30-day mortality was nil. There were two dislocations and only one needed revision surgery due to recurrent dislocation. In conclusion, with optimal patient selection, THA seems to provide a good functional outcome and pain relief in the management of displaced intracapsular femoral neck fractures. Excellent outcome can be achieved when done well using the standard cemented THR and with 28mm head. A good soft tissue repair and a specialist hip surgeon is preferable.
One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface. Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points.Background
Methods
Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported. We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss. Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point. Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma. It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture.
Primary total hip replacement (THR) in patients with abnormal/altered proximal femoral anatomy/narrow canals presents a technical challenge. There are only limited standard prosthetic stems available to deal with narrow canals or abnormal morphology. Many prefer to use expensive custom implants which often have a lag time to manufacture and do not always have long term published outcomes. We present results of the Asian C-stem (which is a standard implant available on the shelf) used in patients predominantly of Caucasian origin with abnormal proximal femoral anatomy. We retrospectively reviewed clinic-radiological results of 131 patients (131 stems) who underwent primary THR using Asian C-stem at Wrightington Hospital till their latest follow up. Revision for any reason was considered as primary end point. Mean age at surgery was 50.8 years (16 – 80). The 2 commonest indications were primary osteoarthritis (66 patients) and hip dysplasia (54 patients). Mean follow up was 43.5 months with a minimum follow up of 12 months and maximum follow up of 97 months. There were 2 recurrent dislocations and 1 hip subluxed twice. One dislocation needed revision surgery. 1 patient underwent acetabular revision for loosening. There was no stem failure, obvious loosening or loss of fixation in any patients in our series with regards to the Asian C-stem. There were no infections and intra-operative perforations or fractures. C-stem Asian is a reliable implant for patients undergoing THR with abnormal proximal femoral anatomy or narrow canals. Long term follow up is essential.
A grossly deformed knee is believed to be an indication for PS -TKA. However, the role CR-TKA in such knees is unclear in the literature. Considering the obvious advantages of CR, we analysed the mid term follow up of CR knees in gross deformities. 1590 patients (1740 knees) underwent TKA between January 2011 to December 2012, out of which 570 knees had gross deformity (varus > 15°, FFD > 10°, valgus > 10°, recurvatum > 10). CR-TKA was performed for 540 knees and were included in our study. Subvastus approach was used for all knees. Average age being 68 years, mean BMI being 32 and average weight 70 kgs. Intraoperatively, POLO test was used to ensure PCL stability, further confirmed by direct palpation. Femoral roll-back was found adequate.Background
Materials and Methods
Subvastus approach for Total Knee Arthropalsty (TKA) allows a faster recovery. It is traditionally not utilized for revision surgeries because of difficulty in exposure of the knee and eversion of the patella. It is considered to have limited indications. We hypothesized that revision TKA should not really pose a problem as the exposure gained is adequate with added advantage of preserving the extensor mechanism, thereby allowing faster functional recovery. We present an analysis of the use of subvastus approach for revision TKAs. 50 patients (50 knees) 37 females + 13 males with mean age 68 years underwent revision total knee arthroplasty (TKA) by subvastus approach between January 2006 to January 2013. All patients were prospectively evaluated by pre- and postoperative Knee Society and function score. The average follow-up was 24 months (range from 1 to 3 years) with minimum 1 year follow-up. The indications for revisions were aseptic loosening (20 knees), infection (12 knees), instability (12 knees) and peri-prosthetic fractures (6 knees). Constrained condylar prosthesis (43 knees), hinged prosthesis (6 knees) and custom made prosthesis (1 knee) were fixed using the subvastus approach. Infected knees underwent one or two staged revisions.Background
Materials and methods
The longevity of total hip replacements in young active patients is a cause for concern as increased cyclical loading can result in early loosening of implants resulting in multiple revisions during the patient's lifetime. The study presented demonstrates excellent survival of the HAC-coated femoral stems in young active individuals. 33 Patients under 50 years of age underwent 38 total hip arthroplasties using the JRI Furlong HAC-coated femoral stem. The retrospective evaluation of the prospectively collected data of the cohort at 17 to 25 years is presented.Introduction
Patients/Materials & Methods
This study reports the results of 38 total hip
arthroplasties (THAs) in 33 patients aged <
50 years, using the
JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.
This represents an update of previous reports of the same cohort
at ten and 16 years, which were reported in 2004 and 2009, respectively.
We describe the survival, radiological and functional outcomes at
a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs,
one underwent femoral revision for peri-prosthetic fracture after
21 years, and one patient (one hip) was lost to follow-up. Using
aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular
revision but none needed femoral revision, demonstrating 100% survival
(95% confidence interval 89 to 100). In young patients with high demands, the Furlong HAC–coated femoral
component gives excellent long-term results. Cite this article:
Stoppa approach has recently been adapted for pelvic surgery as it allows direct intra-pelvic reduction and fixation of the quadrilateral plate and anterior column. We report our early experience, indications and complications with this exposure introduced in 2010 in our tertiary unit. A Retrospective review of all Stoppa approaches in pelvic-acetabular fixations was performed from a prospectively maintained database. Of the 25 patients, mean age 40 years (range 15–76), who underwent pelvic-acetabular fixation using Stoppa approach, 21 patients had mean follow up of 7.3 months (1–48 months). All except 24% of patients had one or more additional systemic injury some requiring additional surgery. There were 6 acetabular fractures, 13 pelvic ring injuries and 6 combined fractures. Mean injury-surgery interval was 9 days (range 3–20). 8 patients had an isolated Stoppa approach whilst the remaining others also had an additional approach. Mean surgical time was 239 minutes. Anatomical reduction was achieved in 96% (24/25) cases. There was 1 minor intra-operative vascular injury, repaired immediately successfully, and no late wound infections, or other visceral complications. One patient reported new onset sensory numbness which resolved after the first review. Two patients reported erectile dysfunction thought to be caused by the initial injury. One patient had asymptomatic plate loosening. None required revision surgery. Despite the obvious learning curve, we found this approach safe and it did not compromise accuracy of reduction in well selected patients, but early surgery within 10–14 days is recommended to aid optimal reduction.
The radiological evidence of implant failure following plate fixation of traumatic pubic symphysis diastasis can be up to 75%. We report the complications following symphyseal double orthogonal plating in patients with pubic symphysis diastasis over a period of 2.5 years. Patient records and radiographs of 38 consecutive patients were reviewed with mean follow up of 12.5 months. 5 patients (13%) had radiological evidence of implant failure with one patient (2.6%) requiring revision surgery. There was no evidence of wound complications. We conclude that our lower rate of revision surgery and metal work failure is attributed to double orthogonal plating.
Whiplash injury is surrounded by controversy in both the medical and legal world. The debate on whether it is either a potentially serious medical condition or a social problem is ongoing. This paper briefly examines a selection of studies on low velocity whiplash injury (LVWI) and whiplash associated disorder (WAD) and touches upon the pathophysiological and epidemiological considerations, cultural and geographical differences and the effect of litigation on chronicity. The study concludes that the evidence for significant physical injury after LVWI is poor, and if significant disability is present after such injury, it will have to be explained in terms of psychosocial factors.
Hip replacement is a very successful operation and the outcome is usually excellent. There are recognised complications that seem increasingly to give rise to litigation. This paper briefly examines some common scenarios where litigation may be pursued against hip surgeons. With appropriate record keeping, consenting and surgical care, the claim can be successfully defended if not avoided. We hope this short summary will help to highlight some common pitfalls. There is extensive literature available for detailed study.
Morbidity of any surgical procedure is undefined. Major surgeries and minor surgeries have different morbidities but the morbidity after any surgical procedure is neither quantified nor defined in literature. Minimally invasive surgeries have evolved in all surgical branches and are known to have less morbidity after the surgery. There is no score or index to assess early recovery after any surgical procedure. The objective of the study was to develop a scoring method to assess early post operative recovery of TKR patients.Background:
Aim:
The gamma nail is a cephalomedullary implant used in proximal femoral fracture management. Short gamma nails are technically less demanding, but there is concern over potentially higher complication rate. To determine differences in implant related complications between the short and long gamma nail.Introduction
Objectives
The current literature tends to suggest that all the different approaches used for Knee Arthroplasty give similar results. The literature also cautions that the MINI quadriceps sparing approaches are to be utilized in very select cases as they are difficult to perform, take longer time, have a greater intra-op complication rate and are associated with a higher number of component malpositioning. Despite these warnings of the literature, the author has been impressed by the physiological nature of the subvastus approach for knee arthrotomy and the author has used this approach exclusively for all Knee arthroplasties in the last 4 years. All primary Knee Arthroplasties have been performed through the mini-subvastus approach, utilizing the principle of a mobile window, irrespective of the degree of pre-operative deformity, obesity, range of motion or previous surgery. All revision Knee Arthroplasties have also been performed through the subvastus approach. All the surgeries have been performed in the private sector in a highly competitive environment with the patient having easy access to various other high volume surgeons performing arthroplasties through a more standard approach. To define the place of the subvastus approach in Knee arthroplasty on the basis of surgical experience gained after 1350 consecutive surgeriesBackground
Aim
Background Computer navigation is increasingly being recognized as a valuable tool in restoring the mechanical axis post TKR. Its use is as yet not universal due to the costs involved, its availability and the fact that it can be cumbersome and time consuming to use. Additionally it requires the insertion of Schanz pins in the femur as well as the tibia which can be a matter of concern as regards stress fracture and infection. However, it is able to reliably locate the center of the femoral head which is an elusive landmark in the standard method. The center of the ankle involves registration for the medial and lateral malleoli which are subcutaneous and easily palpable. We decided to navigate only the distal femoral cut with a specialized navigation unit called Articular Surface Mounted navigation which does not require the insertion of additional pins through the femur or the tibia. We purposely did not use navigation for the rest of the bony cuts as all the other landmarks i.e. femoral epicondyles, tibial malleoli, and tuberosity etc are all easily palpable. This dramatically reduced the surgical time and increased its user friendliness. We are presenting our results. To analyse the radiographic results obtained with selective femoral navigation and compare with standard navigational results from the literature Non-navigated Knees form personal series. We have utilized the ASM navigation for distal femoral cut in 112 knees and obtained long X-rays (scanograms) and routine knee X-rays (AP, Lateral and skyline) to study the mechanical axis and component positioning. We measured the mechanical axis deviation, femoral and tibial angle on AP and lateral films and patellar tilt or subluxation on post-operative X-rays by a digital imaging programme called Image–J. (As suggested by the Knee Society roentgenographic Score). We have compared our results with other navigated series from literature and our own series of non-navigated knees. (113 knees) We also noted the surgical time to perform the operation and the occurrence of any complications.Aim
Materials and Methods
We are presenting a prospective analysis and assessment for the results of the Coflex@ inter-spinous dynamic stabilization device with a 2 year follow up. The purpose of this study is to assess the efficacy and safety of the Coflex@ Posterior Dynamic Stabilization Implant. A prospective analysis was performed on 121 patients (176 devices) treated with the Coflex@ Interspinous Implant. Indication for the treatment was spinal canal foraminal stenosis with nerve root irritation. Pre- and postoperative disability and pain scores were measured using Oswestry disability score, functional assessment a radiological evaluation at pre-operative - three - six twelve and twenty-four month interval. Data analysis revealed a high rate of patient satisfaction 92% of patients are satisfied and will have the surgery again 81% of patients had major improvement of their leg symptoms. 72% of patients reported improvement of their back pain symptoms this was more noted in the decompression group. Two revision surgeries were carried out. One due to implant back-out and the second due to infection. The Coflex@inter-spinous implant is a simple surgical treatment strategy with a low risk. Early results show a good improvement of both clinical and radiological parameters combined with patient satisfaction with better outcome achieved if combined with spinal decompression.
Obesity has been associated with degenerative osteoarthritis of knee joint The over all incidence of osteoarthritis of the knee is also more in patients with obesity. Increasing obesity leads to faster progression of OA, which is due to increased joint load. Body mass index (BMI), dividing an individual’s weight (in kg) by his or her height (in square meters). BMI: Normal = 18.5 to 24.9, Overweight BMI −25–29.9 Obese=30 to 39.9, Morbidly Obese BMI 40 or Greater. Recent article focused on the thigh girth of obese patients and opined that if thigh girth >
55cms, subvastus approach should not be utilized, as it is difficult to evert the patella. We believed that obesity should not really cause a problem for the patients undergoing a TKA with the mini subvastus approach as the anatomy of the quadriceps in the obese and the non-obese patient population is the same. We decided to evert the patella only after osteotomy of tibia and the femur. All patients who underwent primary total knee arthroplasty with minisubvastus approach between January 2006 to July 2007 and who were obese (BMI>
30) were included in our study. Out of 425 primary Total knee arthroplasty were performed during this period. Out of these, there were total 97 obese patients with 109 knees which form the part of the study. There were 81 females and 16 males and 12 patients had staged bilateral knee arthroplasty. The weight varied from 63 to 125 kgs. 91 patients had varus deformity of <
15 degree, 15 patients had varus deformity of >
15 degree, 3 patients had valgus deformity. The thigh girth in obese group (BMI: 30–40) ranged from 45 to 58 cms with average of 50.17. The thigh girth in morbidly obese (BMI >
40) group ranged between 55 to 67 with average of 61.01 cms. Mini-subvastus approach provided satisfactory exposure in all knees that were operated. In no case was this approach abandoned. The average surgical time was 90 minutes with range. The average blood loss was 400 cc. The patellar tracking was immaculate in every case and in fact it was difficult to displace patella laterally after 30 degrees of knee flexion. Our 89 patients had flexion of >
120 0,and 20 patients had flexion of >
90 but <
120. The knee society score improved from average 42 (range 17–62) preoperatively to 89 (range 72–95) post operatively. The Knee Society functional score improved from 48 (range 15–60) pre operatively to 65 (range 50–80) post operatively. Mini subvastus approach offers adequate intraoperative exposure even in obese and morbidly obese patients. It did not result in increased complications in our hands even in morbidly obese patients with higher thigh girth. It is extremely patient friendly and its wider use is recommended.
We report 114 of 117 (97% follow up) consecutive metal-on-metal hip resurfacings in 105 patients with a minimum of 5 years follow up implanted between October 1999 and May 2002. Revision of either the femoral or acetabular component during the study period is defined as failure. No other revisions have been performed or are impending. We had 4 failures giving us survivorship at 5 years of 97% (95% confidence interval (CI) 94 – 100). The mean follow up was 72 months and the mean age at implantation was 54.5 years old (Range 35 – 75). All patients were followed up clinically and radiographically. The mean Harris hip score at follow up was 96.4. The mean Oxford Hip Score fell from 41.6 preoperatively (Range 16 – 57) to 15.3 postoperatively (Range 12 – 49) p<
0.0001. The UCLA Activity Scale rose from 3.93 preoperatively (Range 1 – 10) to 7.54 postoperatively (Range 4 – 10) p<
0.001. Radiographic analysis revealed an average stem shaft angle of 130.6 degrees (Range 112 – 148) with average cup alignment of 36 degrees (Range 22 – 47). Neck thinning was present in 12 hips (10%) and we define a technique for measuring thinning. Heterotropic ossification was present in 17 hips and lucent lines around the femoral component in 10 hips. This study confirms that metal-on-metal resurfacing produces an excellent clinical and functional outcome in the younger patient who requires surgical intervention for hip disease. The results compare favourably with those from the originating centre and confirm that resurfacing is well suited for younger higher demand patients. It is the first study with a minimum 5 year follow up from outside the originating centre.
The mean Harris hip score at follow up was 96.4. The mean Oxford Hip Score fell from 41.6 preoperatively (Range 16–57) to 15.3 postoperatively (Range 12–49) p<
0.0001. The UCLA Activity Scale rose from 3.93 preoperatively (Range 1–10) to 7.54 postoperatively (Range 4–10) p<
0.001. Radiographic analysis revealed an average stem shaft angle of 130.6 degrees (Range 112–148) with average cup alignment of 36 degrees (Range 22–47). Neck thinning was present in 16 hips (14%) and we define a technique for measuring thinning.
Delays in the surgical treatment of acetabular fractures often results in extensile or combined approaches being required. This study reports the outcome from a regional centre aiming to treat these fractures via a single surgical approach where possible. Seventy-two patients (73 displaced acetabular fractures) with an average age of 39.5 years (range 15–76 years) were studied with an average follow up period of 45.5 months (range 24–96). All radiographs were reviewed together with a full clinical assessment of each patient including the Harris Hip Score. Thirty-four fractures were simple and 39 were complex including 27 both column fractures. Eight were noted to have an associated injury to the femoral head. The average time from injury to surgery was 11.7 days (range 1–35 days) with 80 percent of cases being operated on within two weeks after injury. In 67 fractures (92%), including 24 both column fractures, a single approach alone was used (Anterior Ilioin-guinal 26 cases; Posterior Kocher-Langenbeck 41 cases). Five fractures needed an extensile triradiate approach and only one case required a combined anterior and posterior approach. A congruent reduction (gap or step of 2mm or less) was achieved in 65 cases (89%). Functional outcome was good with an average Harris Hip Score of 85 (range 20–100). There were 2 cases of deep infection (2.7%) and 4 patients (5.5%) required later hip replacement. There were no cases of venous thrombosis. Twenty cases exhibited heterotopic ossification of varying degree but none of these were grade IV.
The Phantom based Computer assisted orthopaedic surgical system (CAOSS) has been developed collaboratively by the University of Hull and the Hull Royal Infirmary, to assist in operations like dynamic hip screw fixation. Here we present summary of our system. CAOSS comprises a personal computer based computer system, a frame grabber with video feed from a C-arm image intensifier, an optical tracking system and a radiolucent registration phantom which consists of an H arrangement of 21 metal balls. The phantom is held in position by the optically tracked end-effector. Knowing the optical position of the phantom, a registration algorithm calculates the position of C-arm in coordinate space of the optical tracking system. Computer based planning uses an anteroposterior (AP) and lateral image of the fracture. Marks are placed on the 2D projections of femoral shaft, neck and head on the computer screen, which are then used to create 3D surgical plan. The computer then plans a trajectory for the guide wire of DHS. The depth of the drill hole is also calculated. The trajectory is then shown on both AP and lateral images on the screen. CAOSS meets all the requisite of electrical and electromagnetic radiation standards for medical equipment. There has been extensive validation using software simulation, performance evaluation of system components, extensive laboratory trials on plastic bones. The positional accuracy was shown to be within 0.7mm and angular accuracy to be within 0.2°. The system was also validated using Coordinate Measurement Machine. Our system has the unique feature of the registration phantom which provides accurate registration of the fluoroscopic image.
Though the perceived advantages of computer assisted orthopaedic systems (CAOS) have been claimed incessantly over the years, these systems are far from commonplace in most orthopaedic theatres. Here, we present a summary of those very reasons. Health Technology Assessment report elicited no proof of clinical benefits of the Robodoc over conventional procedures. Mazoochian et al were unable to confirm the same accuracy of implant position while using the Caspar. Honl et al found a higher revision and dislocation rate accompanied with longer surgery durations when robotic assisted technology was used. Shortcomings identified in the CT-based navigation systems included an additional CT scan, which represents extra costs for the acquisition as well as additional radiation to the patient. Sistan et al claims that image-free navigational systems in knee arthroplasty do not provide a more reliable means for rotational alignment as compared to traditional techniques. Computer assisted pedicle screw insertion in the spine has also not demonstrated any significant clinical advantages. To date, long term results of computer-guided or robot-assisted implantation of endoprosthetic devices are still lacking. With the unproven long-term clinical and functional results of patients who had computer aided surgery and given the multi-factorial complexities of patient outcome, it is difficult to claim via small scale short term studies that these systems present a significant benefit to the patient or the healthcare providers. Potential benefits of long-term outcome, better implant survival and functional improvement require further investigation and until that information is available this technology must be further developed before its widespread usage can be justified.
Substantial bone loss and bone defects are the most challenging problems faced by the surgeon performing revision surgery. Of the many techniques available, impaction bone grafting aims to achieve stability of an implant with the use of compacted, morselized bone graft and subsequently allows restoration of bone stock by bone ingrowth. This technique was proposed with a highly polished double tapered stem. This technique has also been subsequently used with stems of varying surface finish and shape. We report here our experience with impaction grafting using Charnley stem and variants with 8–10 year results assessing the radiological appearance and subsequent behaviour of the impacted allograft. A prospective radiological study of revision hip arthroplasty done for aseptic loosening with femoral bone loss is presented. Pre operative bone loss was assessed using the Endo Klinik grading system. Impaction grafting with fresh frozen femoral head allograft and the flanged 40 size Charnley stem was used in 17 cases and extra heavey flanged 40 size was used in 9 casaes. Post operative and annual review radiographs were examined for graft distribution, graft consolidation, cortical repair and subsidence of the stem. Twenty six revisions performed in 25 patients between May 1994 and November 1996 were followed up for 8–10 years. Mean age was 66 years(range 26–83 years). There were eighteen male and 7 female patients. One patient died 2 years and 9 months after the operation. Pre operatively Endo Klinik grade 2 bone loss was seen in 7 cases and grade 3 bone loss was seen in 19 cases. Post operative radiographs showed even graft distribution in twenty cases, five patients had poor filling in Gruen zone 3 and one patient had poor filling in zone 2. All cases demonstrated evidence of graft consolidation by one year. Twenty two cases showed no further changes after 8–10 years. Two cases of subsidence have been revised and one patient is awaiting revision ( 8 years after revision). Two of these were extra heavy flanged 40 stems. Three cases showed subsidence >
5mm and were associated with graft deficiency in zone 2 or 3. Out of these three one had an extra heavy flanged 40 stem inserted. There were no medical complications or deep infection following surgery in these patients. One patient had dislocation. In conclusion, femoral revision using impaction grafting with the Charnley stem produces satisfactory radiological results in the medium to long term. Good graft distribution on a postoperative radiograph is associated with graft consolidation, cortical repair and minimal stem subsidence. Extra heavy flanged 40 stems perform less satisfactorily compared to the flanged 40 stems. Inadequate graft filling is associated with stem subsidence and revision. These findings highlight the importance of meticulous surgical technique to ensure even graft distribution. This study supports the taper of the Charnley stem and suggests that a vaquasheen finish is not contraindicated.
The indication for revision was aseptic loosening in 16 cases, and deep sepsis in 13 cases, (12 were done in 2 stages). Others included polyethylene wear in 4 knees, instability in 2, and 1 each of peri-prosthetic fracture, implant breakage and pain of undetermined origin. 3 revisions were performed for failed Link Lubinus patello-femoral replacement. Mean interval between staged procedures for sepsis was 2 months. Reconstruction was performed using the Kinemax Revision system with the use of augments and stems. The modular rotating hinge was used in 4 cases. Surgical exposure included additional lateral release in 7 cases, tibial tubercle osteotomy in 4 and quadriceps snip in one.
At latest review, 7 patients had died due to unrelated causes with a pain free functioning knee prosthesis. Of the remaining 31, 26 patients had none or minimal pain. 21 were independently mobile with a satisfactory range of motion.10 patients needed a walking stick.