Abstract
Background
Subvastus approach for Total Knee Arthropalsty (TKA) allows a faster recovery. It is traditionally not utilized for revision surgeries because of difficulty in exposure of the knee and eversion of the patella. It is considered to have limited indications. We hypothesized that revision TKA should not really pose a problem as the exposure gained is adequate with added advantage of preserving the extensor mechanism, thereby allowing faster functional recovery. We present an analysis of the use of subvastus approach for revision TKAs.
Materials and methods
50 patients (50 knees) 37 females + 13 males with mean age 68 years underwent revision total knee arthroplasty (TKA) by subvastus approach between January 2006 to January 2013. All patients were prospectively evaluated by pre- and postoperative Knee Society and function score. The average follow-up was 24 months (range from 1 to 3 years) with minimum 1 year follow-up. The indications for revisions were aseptic loosening (20 knees), infection (12 knees), instability (12 knees) and peri-prosthetic fractures (6 knees). Constrained condylar prosthesis (43 knees), hinged prosthesis (6 knees) and custom made prosthesis (1 knee) were fixed using the subvastus approach. Infected knees underwent one or two staged revisions.
Results
The approach provided adequate exposure in all revisions. The average Knee Society score improved from 42 to 83 and the function score from 48 to 65. The complications included medial collateral ligament injury (one case), patellar tendon avulsion (one case) and mal-tracking patella (one case). Average hospital stay was 4 days. Average blood lose was 400 ml.
Conclusion
Our results compare favourably with other reported series on revision TKA. The subvastus approach can be considered for revision TKAs.