header advert
Results 1 - 43 of 43
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 48 - 48
1 Jul 2022
Blucher N Fletcher J Platt N Porteous A
Full Access

Abstract

Introduction

Controversy exists regarding the optimal tibial coronal alignment in total knee arthroplasty. Many believe navigation or robotics are required to set kinematic alignments or to ensure they remain within ‘safe’ limits e.g. maximum 5° varus on the tibia. Given most navigation or robotic systems require the surgeon to identify the ankle malleoli, this study aimed to radiographically analyse standardly used intra-operative landmarks around the ankle, assessing their value in achieving kinematic alignment / setting safety boundaries.

Materials and Methods

Long leg alignment radiographs were analysed independently by two orthopaedic surgeons at two time points, eight weeks apart. Angles were measured between the long axis of the tibia (TB) and: 1. lateral malleolus (TB-LM), 2. lateral border of the talus (TB-LT) and 3. medial aspect of the medial malleolus (TB-MM). Intra- and inter-rater reliabilities were assessed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 58 - 58
1 Jul 2022
Joshi A Gupte C Bhattacharyya R Ahmad K Porteous A Murray J Murray J
Full Access

Abstract

Introduction

In recent years, CTA has been an effective training adjunct for orthopaedic procedures. ACLR is a complex procedure with a steep learning curve.

Aim

To design a multimedia CTA learning tool for ACLR using a modified Delphi methodology.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 43 - 43
1 Nov 2018
Beswick AD Strange S Mallon C Lenguerrand E Moore AJ Kunutsor SK Whitehouse MR Porteous A Toms A Blom AW
Full Access

Patients with knee prosthetic joint infection (PJI) frequently receive one- or two-stage revision. To explore the feasibility of a randomised controlled trial (RCT) comparing methods, we analysed a UK registry, interviewed patients and surgeons, systematically reviewed literature, held a consensus meeting, and assessed progress of an RCT in hip PJI. In 2014, in England and Wales, knee PJI was treated with one- or two-stage procedures in 19% and 71% of patients respectively. Between 2007 and 2014, use of one-stage procedures doubled and, in major centres, up to 42% of treatments were one-stage. We conducted in-depth interviews with 16 patients with knee PJI and 11 surgeons performing one- or two-stage revision. Patients considered randomisation acceptable with appropriate counselling and, depending on infecting organisms and health status, surgeons would randomise treatments. In meta-analysis, two-year re-infection rates in 10 one-stage series (423 patients) and 108 two-stage series (5,129 patients) were 7.6% (95%CI 3.4,13.1) and 8.8% (7.2,10.6) respectively. In a series of patients with knee PJI, surgeons from 2 major centres considered 6/15 patients eligible for either treatment, with 4 more potentially eligible after treatment of soft tissue infection. In an ongoing RCT of surgical treatment of hip PJI, 116 patients have been randomised at 14 centres in 3 years. Randomising patients with PJI is feasible but, as knee PJI is uncommon, a multicentre RCT would be required. Based on WOMAC score outcome and appropriate assumptions on eligibility and acceptability, 170 patients would need to be randomised over 4 years at 14 major centres.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 10 - 10
1 May 2015
Barksfield R Porteous A Robinson J Murray J
Full Access

A key theme of the GIRFT project is centralisation of complex orthopaedic procedures to “Specialist Units” and minimum surgeon volumes. We aimed to estimate the effects of implementing minimum unit and surgeon specific volumes upon orthopaedic units within the Severn region.

Practice profiles for surgeons and units were generated using the NJR Surgeon and Hospital Profile Database. Minimum volume thresholds were set at 13 procedures/year for surgeons and 30 procedures/year for units.

Median surgeon volumes were 33 (range 2–180) for primary TKR, 10 (range 2 – 64) for UKR, 2 (range 2 – 41) for PFJR and 5 (range 2–57) for Revision TKR. Amongst 48 surgeons performing UKR, 26 (54%) performed less than 13 procedures per year accounting for 108 (14%) procedures. Amongst 20 surgeons performing PFJR, 19 (95%) performed <13/year, accounting for 56 (58%) of cases. 49 Surgeons performed revision TKR with 24 (49%) performing <13 revisions per annum, accounting 151 (36%) procedures.

Amongst 16 units performing UKR, 8 (50%) performed <30/year, accounting for 16% overall. Revision TKR was performed in 15 units whilst 8 (53%) performed <30/year, accounting for 62 (15%) cases. We invite discussion of the ramifications of minimum surgeon and unit volumes for Orthopaedic services in the Severn Region.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 4 - 4
1 May 2015
Metcalfe A Hassaballa M Gill N Ackroyd C Murray J Porteous A Eldridge J
Full Access

The aim of this study was to document the survivorship and patient reported outcome of the Avon patello-femoral replacement in a consecutive series with follow up of 10 years or more.

All cases performed in Bristol from 1996 onwards were prospectively recorded. Follow up was at 1,2,5,7,10,12 and 15 years with the Bristol Patella Score, the Oxford and WOMAC scores and SF12. Implant survival was analysed using the Kaplan-Meier method.

There were 323 PFJ replacements (280 individuals). Follow up was available for 286 cases in 250 patients (89% follow up). The 10 year survival rate was 77%, falling to 67% at 15 years. The most common reason for revision was tibio-femoral progression (45/74 revisions), with loosening or polyethylene wear recorded in 8 cases. The best results were seen in the youngest and the oldest patients. Good improvements were seen in PROMs, with the mean OKS improving from 19.5 to 34.1 at 2 years and 32.7 at the 15 years.

The Avon patello-femoral knee replacement is a successful long-term treatment for isolated patello-femoral knee osteoarthritis, although further improvements are expected in subsequent series, particularly as indications for surgery have evolved over time.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 3 - 3
1 Mar 2014
Mihok P Bex C Hassaballa M Robinson J Murray J Porteous A
Full Access

Total knee arthoplasty (TKA) remains a standard treatment for advanced knee arthritis. The aim of the procedure is to restore function and relieve pain ideally for the rest of patient's life. Patient matched templating (PMT) or patient specific instrumentation (PSI) is a recent development for alignment of TKA components that uses disposable guides. The users of PSI claim it to be the optimum balance of new technology and conventional technique by reducing the complexity of conventional alignment and sizing tools.

To assess the clinical and radiological outcome of Primary TKA done with PSI.

More than 200 cases of TKA have been done in our unit using PSI and we analysed the radiographic outcome of these cases postoperatively. We also reviewed the clinical outcome of 103 patients with 1 year and 43 patients with 2 year follow-up. Data was collected prospectively: pre-operatively and at 1 year and 2 years post-operatively including Oxford knee score (OKS), WOMAC and American knee society score (AKS). Standard AP and lateral films were done pre-operatively and post-operatively.

Mean age was 66 years. There were 56 female and 47 male patients. Mean post-operative angles on standard films were: Alpha = 95.6, Beta = 88.4, Saggittal femur = 3.4 and Saggittal tibia = 90.8. Of the 103 cases with 1 year follow-up, there was significant improvement in all clinical outcome scores. Mean OKS improved from 18 to 39 at 1 year and remained the same at 2 years, WOMAC improved from 40 to 18 in both 1 and 2 years post-op. AKS Total improved from 79 to 173 at 1 year and 170 at 2 years.

Performing TKA using PSI is safe and provides good radiological alignment in the coronal and sagittal plane. Significant improvement in outcome scores were seen at one and two year follow up and reached levels that compared favourably with other reported series of TKA outcome from our unit.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2014
Mihok P Hassaballa M Robinson J Porteous A Bowker K Lovering A Murray J
Full Access

It has been reported that some of the local anaesthetic agents possess antimicrobial activity against clinically-significant bacteria. Although bupivacaine exhibits a bacteriostatic effect at concentrations above 0.25% there are concerns that it might interact with some of the other antibiotics administered to patients. Whilst these interactions may be potentially benign, the risk is that they are antagonistic and that local bupivacaine might predispose the patient to a higher risk of infection.

Bupivacaine is commonly administered as a local anaesthetic following knee arthroplasy; the purpose of this study was to assess its potential interactions with gentamicin eluting from the cement used to fix the device.

A strain of Saphylococcus aureus (29213) with established susceptible Minimal Inhibition Concentration (MIC) and Minimal Bactericidal Concentration (MBC) for gentamicin was used. This organism was inoculated into four types of broth; Mueller-Hinton broth (MH), MH with different concentrations of gentamicin, MH with 0.25% and 0.125% bupivacaine and MH with various combinations of gentamicin and bupivacaine. The broths were incubated at 37C and at 0.5, 1, 2, 3, 6 and 24 hours post inoculation the number of bacteria remaining were counted. From these data kill-curves were generated describing the absolute and individual rates of killing seen with bupivacaine and gentamicin alone and when in combination.

Bupivacaine showed a bacteriostatic effect only at concentrations of 0.25% and higher. All concentrations of gentamicin above or equal to the expected MBC showed bactericidal effect. However, in combination with both strengths of Bupivacaine (0.25 and 0.125%) the bacteriocidal effect of gentamicin was seen at a lower concentration and the rate of killing of bacteria was enhanced.

Bupivacaine has bacteriostatic effect at concentrations above 0.25% in line with published data. In these experiments we have shown that the use of bupivacaine together with gentamicin does not reduce the bactericidal property of the antibiotic and that the bactericidal effect of gentamicin appears to be enhanced by bupivacaine. This would suggest that the local use of bupivacaine is unlikely to increase the risk of infection in patients undergoing knee arthroplasty and may actually be beneficial.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 5 - 5
1 Mar 2014
Hassaballa M Artz N Mihok P Chapman L Robinson J Porteous A Murray J
Full Access

This is a prospective review of consecutive patients who underwent knee revision surgery using the Legion knee system.

Clinical and functional assessments (American Knee Scores-AKS, WOMAC and Oxford knee score-OKS) were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2 years included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction.

210 patients underwent revision knee system 103 male: 107 females with a mean age of 66.4 (44–87) yrs. Mean BMI-26.03 (21–50). We had a 2-year follow up for 110 patients. Surgery was carried out at a single centre and performed by Bristol knee specialists.

Indications for surgery were aseptic loosening (84), infection (27) instability (47), pain and stiffness (31), progression of disease (6), peri-prosthetic fractures (15)

The AKS and WOMAC scores at, 1 year and 2 years follow up showed significant improvements in pain and function. The mean total AKS improved from 75.7/200 pre-operatively to 140.5/200 at 2 yrs. Radiographic assessment showed a mean AP coronal femoral angle of 95.3 degrees (89.6–99.9), coronal tibial angle of 90.1 degrees (88–92). The mean sagittal femoral and tibial angles were 88.4 and 90.4 degrees respectively.

The short-term results showed significant improvement in functional and pain scores irrespective of indications for revision surgery. The Legion system has showed good outcome scores that match or beat published series on revisions. It also showed a good ability to restore joint line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 33 - 33
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the clinical outcome at 1 year of 30 cases of primary TKA performed with PMCB.

Method

Data was collected prospectively pre-operatively on over 100 primary TKA's performed with PMCB. Of these cases, 30 have reached a point of 1 year follow-up. Validated outcome measures including American Knee Society score, Oxford Knee Score and WOMAC were completed pre-operatively and at 1 year. Radiographic analysis of alignment was performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 41 - 41
1 Mar 2013
Porteous A Ansari A Murray J Eldridge J
Full Access

Aim

To analyse the available rotating hinge knee implants available on the market with a view to deriving a rational algorithm for implant selection.

Method

Information on available hinge designs was gathered from the literature and further questionnaires were sent to the relevant implant companies asking for more specific information regarding the minimum bone resection necessary to accommodate the implant, the maximum bone loss that can be compensated with augments, method of transmission of forces, type and size of stems, availability of metaphyseal-filling cones and cost.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 42 - 42
1 Mar 2013
Porteous A Gbedjuade H Murray J Hassaballa M
Full Access

Aim

To assess the outcome and complication rate of rotating hinge knee prostheses in our unit.

Method

From our knee database we have identified 137 consecutive rotating hinged TKRs (implanted 2004–2010) for severe instability, arthrofibrosis and severe bone loss in either primary or revision arthroplasty. Prospective pre-operative scores and post-operative scores were obtained. 23 had died or were lost to follow-up. This left 114 cases with complete outcome and complication data.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 43 - 43
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Objectives

The aim of this study was to study the short to medium term outcome of a contemporary modular revision knee system used in our centre for managing knee revision arthroplasty.

Methods

Between July 2006 and October 2011, 153 revision cases were done using the Legion revision system. Seventy eight cases completed a 2 years follow up. Preoperative, one and two years follow up scores and radiographic analysis were recorded. Outcome measures included the American Knee Society (AKSS), Oxford (OKS) and WOMAC scores. The American knee society radiographic analysis system was employed to assess assessment standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre=op/post-op) was deemed satisfactory.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 31 - 31
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the process of using patient matched cutting blocks in Primary TKA with respect to: radiology, the proposed engineering plans, the process in theatre and cost effectiveness. Background: Patient matched cutting blocks (PMCB) are the subject of much interest in primary TKA. Our unit has experience of over 100 cases with a single system.

Method

We have analysed our initial experience with PMCB. We have compared the sizes of implants used in theatres versus the sizes predicted on the image-generated plans. We have assessed the potential time saving in theatre, during each case and in the turn-around time between cases. We have also looked at the number of trays of instruments used in PMCB versus non-PMCB cases.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 34 - 34
1 Mar 2013
Porteous A Murray J Robinson J Wilson R
Full Access

Aim

To assess the accuracy of predicted and actual cut alignment from PMCB versus intra-operative computer navigation.

Method

We performed 10 primary TKA cases in which both PMCB and computer navigation were used. Standard imaging was performed to generate the plan and the cutting blocks to perform the case with PMCB. At the start of the case, standard navigation procedure was followed using the Praxim navigation system to register the centre of the femoral head, femoral and tibial surfaces and alignment. The PMCB were applied to the femur and tibia and the navigation cut-registering shim was placed in the slot on the PMCB to record the position and alignment of the proposed cut in the coronal and sagittal planes. The following parameters were compared: overall limb alignment in the coronal plane, distal femoral coronal angle, depth of resection on medial and lateral distal femoral condyle and depth of resection on medial and lateral proximal tibia. Differences in the pre-operative PMCB plan, intra-operative navigation assessment and proposed cuts after application of the blocks intra-operatively were recorded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 46 - 46
1 Mar 2013
Porteous A Sullivan N Murray J Eldridge J
Full Access

Aim

To assess if there is a reproducible relationship between the width and thickness of the normal patella.

Method

43 MRI scans of young adults, average age 27 (range 17–38) were studied. Exclusion criteria included a diagnosis of degenerative joint disease, patella-femoral pathology or age under 16/over 40 (102 patients). The bony thickness of the patella, the chondral thickness and patella width were measured, as was the location of maximal patella thickness. Inter/intra observer variability was calculated and correlation analysis performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 44 - 44
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the survivorship of unicompartmental replacements (UKR) revised to UKR. Background: Partial revision of UKR, or revision to a further UKR is a rarely performed procedure with some data from the Australian registry suggesting that results are not good, with early revision being required.

Method

All revision procedures from initial UKR are prospectively followed and scored as part of our department's knee database. We analysed the 37 cases in our database that showed revision of UKR to UKR. These included cases in the following categories: a) Mobile bearing revised to mobile bearing (n=8) b) Mobile bearing revised to fixed bearing (n=20) c) Fixed bearing revised to fixed bearing (n=9)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 3 - 3
1 Feb 2013
Gbejuade H Hassaballa M Robinson J Porteous A Murray J
Full Access

The gold standard for measuring knee alignment is the lower limb mechanical axis. This is traditionally assessed by weight-bearing full length lower limb X-rays (LLX). CT scanograms (CTS) are however, becoming increasingly popular in view of lower radiation exposure, speed and supine positioning. We assessed the correlation and reproducibility of knee joint coronal alignment using these two imaging modalities.

LLX and CTS images were obtained in 24 knees with degenerate joint disease or failed TKR. Hip to ankle mechanical alignment were measured using the PACS software. Coronal knee alignment was assessed from the centre of the knee, measuring the valgus/varus angle relative to the mechanical axis. Measurements were made by two orthopaedic surgeons (Research Fellow and Consultant) on two separate occasions.

The mean alignment angles measured by observers 1 and 2 on CTS were 180.29° (SD 6.04) and 180.71° (SD 6.13) respectively, while on LLX were 181.04° (SD7.58) and 181.04° (SD 7.72). The measurements between the two observers were highly correlated for both the CTS (r = 0.97, p < 0.001) and the LLX (r = 0.99, p < 0.001). The angles measured on CTS and LLX were highly correlated (r = 0.826, p < 0.001) with high degree of internal consistency (ICC = 0.804). Malalignment of greater than 5° was seen in 19% of the CTS and 35% of the LLX.

There was good correlation between CT scanogram and weight-bearing X-ray measurements in normally-aligned knees. However, as expected, in the malaligned lower limb, the influence of weight-bearing is critical which demonstrates the significance of weight-bearing X-rays.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 4 - 4
1 Feb 2013
Sullivan N Robinson P Ansari A Hassaballa M Porteous A Robinson J Eldridge J Murray J
Full Access

Patello-femoral arthritis can result in a considerable thinning of the patella. The restoration of an adequate patella thickness is key to the successful outcome of knee arthroplasty.

The objectives were (1) to establish a reproducible patella width:thickness index including chondral surface and (2) to investigate whether there is a difference between bone alone and bone/chondral construct thickness as shown by MRI.

Forty three MRI scans of young adults, mean age 27 (range 17–38), 34 male and 9 female, were studied. Exclusion criteria included degenerative joint disease, patello-femoral pathology or age under 16/over 40 (102 patients). The bony and chondral thickness of the patella and its width were measured. Inter/intra observer variability was calculated and correlation analysis performed.

We found a strong correlation between patella plus cartilage thickness and width (Pearson 0.75, P < 0.001). The mean width:thickness ratio was 1.8 (SD 0.10, 95% CI 1.77–1.83). Without cartilage the ratio was 2.16 (SD 0.15, 95% CI 2.11–2.21), correlation was moderate (Pearson 0.68, P < 0.001). The average patella cartilage thickness was 4.1mm (SD 1.1, 95% CI 3.8–4.5).

The narrow confidence intervals for the ratio of patella width:thickness suggest that patella width can be used as a guide to accurate restoration of patella thickness during total knee or patella-femoral replacement. We would recommend a ratio of 1.8:1.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 20 - 20
1 Feb 2013
Tasker A Hassaballa M Lancaster S Murray J Porteous A
Full Access

We present a prospective, randomised, single-centre, multi-surgeon, controlled trial comparing minimally invasive (MIS) and standard approach total knee arthroplasty (TKA).

86 patients undergoing 92 total knee replacements were recruited. 46 operations were randomised to the MIS treatment arm, 46 to the standard control arm. Data collected included postoperative blood loss, length of stay and complications. Patients underwent surgery via a quadriceps sparing or standard medial parapatella approach. All operations were performed using MIS instruments and an identical postoperative care pathway.

The MIS group had a significantly shorter length of stay (1.4 days, p=0.004) and fewer complications (p=0.003). Demographics, operative time blood loss and radiographic alignment were comparable between the groups. There were no deaths, pulmonary emboli or surgical site infections. 1 patient developed DVT and 1 required revision for pain and failure to regain flexion within 9 months of surgery, both in the control group. Nine percent of MIS patients versus 35% controls suffered a complication delaying discharge, of which 2% and 17% related to surgical site problems respectively.

MIS resulted in a shorter admission and fewer complications, whilst achieving satisfactory component alignment. We discuss the potential economic implications.


We present 10–15 year follow-up of 33 patients who underwent Elmslie-Trillat osteotomy for severe patellar subluxation or dislocation. In the literature it has been reported that tibial tubercle osteotomy predisposes to subsequent patella-femoral arthritis, however it has never been documented if pre-existent knee chondral damage has any role in this development. In our group all patients had pre-op knee arthroscopy performed and extant of chondral damage was documented. We preformed an evaluation by long-term follow-up to determine weather pre-op chondral damage was the cause of subsequent osteoarthritis of patella-femoral joint. All patients were invited to attend outpatient clinic for clinical examination and knee radiographs and assessed by an independent research surgeon. Mean age at follow-up was 43 years and average follow-up was 10.5 years (range 10–15 years). 90% follow-up was achieved. Knee function was assessed by clinical scores (Lysholm knee score, American Knee Score, Oxford Knee score, Tegner and Insall knee scores) and three radiographs (AP, Lateral and Merchant views). Four patients had developed significant arthritis and underwent joint arthroplasty. Majority of patients reported good results with no further dislocation. However we noticed that extant of pre-op chondral damage was a significant factor in subsequent development of patella-femoral arthritis. We will present our data which is unique as no previous such long-term results have been reported for tibial tubercle transfers followed-up for more than 10 years and have pre-op arthroscopic documented chondral damage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 69 - 69
1 Sep 2012
Gbejuade H Hassaballa M Robinson J Murray J Porteous A
Full Access

Introduction

Patients with severe knee instability and extensive bone loss remain a surgical challenge. In such cases, regular knee implants and constrained condylar implants may not be suitable or have been attempted and failed.

Hinged knee replacements have developed an important role in the management of such complex knee cases. They also have an increasingly important role in cases such as rheumatoid arthritis and other cases of severe joint destruction.

We present a review of 138 consecutive hinge knee arthroplasties of 8 different Hinge models performed in our unit between 2004 and 2010.

Method

Combined prospective and retrospective study of 138 (42 primary and 96 revisions) consecutive cases of Hinge knee replacements at a mean follow up of 4.2 years. Outcomes were recorded and scored using the American knee score preoperatively, 1, 2 and 5 years. Complications, re-revisions, implant failures and survivorship were also assessed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 2 - 2
1 Sep 2012
Piper D Halliday R Murray J Porteous A Robinson J
Full Access

Separation of the ACL into anteromedial (AM) and posterolateral (PL) fibre bundles has been widely accepted. The bundles act synergistically to restrain anterior laxity throughout knee flexion, with the PL bundle providing the more important restraint near extension and its obliquity better restraining tibial rotational laxity.

10% of ACL injuries involve isolated rupture to one of these bundles causing patients to present with instability symptoms or pain. As knowledge about the influence of the ACL bundles on knee kinematics has increased, isolated reconstruction of either PL or AM bundle has been advocated. However only one cohort study of 17 patients has been presented in the clinical literature.

KOOS (Knee Injury and Osteoarthritis Outcome Score) and IKDC (International Knee Documentation Committee Form) scores at 1yr post op were obtained for 12 patients who had undergone isolated ACL augmentation between 2007 and 2009. These were compared with previously published outcome scores for standard ACL reconstruction procedures. In addition examination under anaesthesia (EUA) assessments were analysed to see if a pattern of laxity for isolated AM and PL rupture could be determined.

There were 5 patients with isolated AM bundle rupture and 7 with isolated PL bundle rupture. EUA analysis demonstrated that patients with isolated PL bundle rupture had increased pivot shift and Lachman test laxity, whereas the AM bundle rupture group had increased laxity with the anterior drawer test. Compared to previously published IKDC scores, there were no difference between isolated bundle augmentation and standard ACL reconstruction. However the KOOS scores showed significantly increased Sports function scores which was significantly better in the isolated bundle augmentations (93/100 v's 74/100). Differences between isolated AM and PL bundle reconstructions were not distinguishable.

Isolated ACL bundle tears make up a significant proportion ACL injuries. Although technically more difficult than standard ACL reconstruction, isolated bundle augmentation appears to result in improved sports function when compared to standard ACL reconstruction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 29 - 29
1 Jul 2012
Parwez T Hassaballa M Artz N Robinson J Murray J Porteous A Newman J
Full Access

Purpose

The aim of this study was to compare the short-term and mid-term outcome of lateral UKRs using a single prosthesis, the AMC Uniglide knee implant.

Methods

Between 2003 and 2010, seventy lateral unicompartmental knee replacements (mean patient age 63.6±12.7 years) were performed at our unit for isolated lateral compartmental disease. Range of knee motion and functional outcome measures including the American Knee Society (AKSS), Oxford (OKS) and WOMAC scores were recorded from 19 knees at five years' post-operatively and compared to 35 knees at two-years and 53 knees at one-year post-op.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 42 - 42
1 Jul 2012
Hassaballa M Murray J Robinson J Porteous A Newman J
Full Access

Introduction

Kneeling ability is better in unicompartmental than total knee arthroplasty. There is also an impression that mobile bearing knees achieve better functional outcome than their fixed bearing cousins in unicompartmental and to a lesser extent total joint arthroplasty. In the UK, the market leading unicompartmental replacement is mobile bearing.

Aim

To analyse kneeling ability after total and unicompartmental knee replacement using mobile and fixed bearing inserts.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 4 - 4
1 May 2012
Bradford O Burnand H Artz N Hassaballa M Williams M Porteous A Robinson J Murray J
Full Access

Background

Body Mass Index (BMI) is used to quantify generalised obesity, but does not account for variations in soft tissue distribution.

Aims

To define an index quantifying the knee soft tissue depth, utilising underlying bony anatomy, and compare with BMI as a measure of individual patient's knee soft tissue envelopes. We performed a practicality and reproducibility study to validate the Bristol Knee Index for future prospective use.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 30 - 30
1 Mar 2012
Hassaballa M Artz NJ Porteous A Robinson J Murray J
Full Access

Purpose of the study

Assessing medium term outcome of medial Uni compartmental replacement and whether there is a difference in outcome between mobile and fixed bearing variants of the same prosthesis.

Methods

Knee outcome was assessed in 150 patients (81 male, 69 females, mean age 67.0±10.4yrs) undergoing medial UKR knee (Uniglide, Corin Medical, UK) using either fixed or mobile bearing prosthesis between 2002-2007. All operations were performed by members of the Bristol knee group. All patients were scored using the American Knee Score (AKS), Oxford Knee Score (OKS), and WOMAC pre-operatively and at 2-year follow up. The mobile group (n=93) comprised 43 males and 50 females, aged 62.8±8.9yrs. The fixed bearing group (n=57) comprised 38 males and 19 females, aged 74±8.8yrs.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 176 - 176
1 May 2011
Hassaballa M Porteous A Murray J
Full Access

Cutaneous nerve injury occurs commonly with knee arthroplasty, causing altered skin sensation and, infrequently, the formation of painful neuromas. The infrapatellar branch of the saphenous nerve is the structure most commonly damaged.

The aim of this study was to establish the frequency of cutaneous nerve injury with three incisions commonly used in knee arthroplasty.

Ten knees from five cadavers were studied. Skin strips representing three different incisions, were excised and examined for number and thickness of nerves.

There were more nerve endings found in the dermis layer than the subcutaneous fatty layer. There was no significant difference in the total number of nerves when the 3 studied incisions were compared. The lower part of all incisions was found to have more thick and a higher number of nerves than the upper part (P=0.005).

Careful incision placement is required to avoid damage to cutaneous nerves during knee arthroplasty. This may be of long-term advantage to patients especially those for whom kneeling is important.


We present 10–15 year follow-up of 33 patients who underwent Elmslie-Trillat osteotomy for severe patellar subluxation or dislocation. In the literature it has been reported that tibial tubercle osteotomy predisposes to subsequent patella-femoral arthritis, however it has never been documented if pre existent knee chondral damage has any role in this development. In our group all patients had pre-op knee arthroscopy performed and extant of chondral damage was documented. We pre-formed an evaluation by long-term follow-up to determined weather pre-op chondral damage was the cause of subsequent osteoarthritis of patella-femoral joint.

All patients were invited to attend outpatient clinic for clinical examination and knee radiographs and assessed by an independent research surgeon. Mean age at follow-up was 43 years and average follow-up was 10.5 years (range 10–15 years). 90% follow-up was achieved. Knee function was assessed by clinical scores (Lysholm knee score, American Knee Score, Oxford Knee score, Tegner and Insall knee scores) and three radiographs (AP, Lateral and Merchant views) were performed.

Four patients had developed significant arthritis and underwent joint arthroplasty. Majority of patients reported good results with no further dislocation. However we noticed that extant of pre-op chondral damage was a significant factor in subsequent development of patella-femoral arthritis. We will present our data which is unique as no previous such long-term results have been reported for tibial tubercle transfers followed-up for more than 10 years and have pre-op arthroscopic documented chondral damage.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 72 - 72
1 Mar 2009
HASSABALLA M PORTEOUS A Newman JH
Full Access

Introduction: There is an impression among Orthopaedic surgeons that mobile bearing knee replacement has a better functional outcome than fixed bearing knee replacement. Since kneeling demands a high level of function after knee replacement this study was undertaken to see if mobile bearings in either total or unicompartmental replacement conferred an advantage.

Methods: A prospective randomised study of 207 TKR patients receiving the same prosthesis (Rotaglid, Corin, UK) was performed. Patients were randomised into a mobile bearing group (102 patients with a mean age of 53 years) and a fixed bearing group (105 patients with a mean age of 55 years). Data was also prospectively collected on 215 UKR patients who received the same unicompartmental implant (AMC, Uniglide, Corin, UK). 136 patients (Mean age: 62 yrs) had a mobile insert and 79 (mean age: 65 yrs) a fixed insert.

All patients completed the Oxford Knee Questionnaire preoperatively as well as at 1 and 2 years postoperatively. Their stated kneeling ability and total scores were analysed with a perfect score for kneeling ability being 4, and 48 the maximum total score.

Results: In all groups both the kneeling ability and the total scores improved markedly from their preoperative state. At two years the total score for the fixed bearing devices was marginally better than for the mobile (Rotaglide 36;31 and Uniglide 37;33)

There was a more striking difference with respect to kneeling ability with the fixed bearing variants performing better, (Rotaglide 1.4; 0.9 and Uniglide 1.9; 1.4), However, the greatest difference was between the UKR and TKR groups (UKR 1.7; TKR 1.2). Pre-operatively less than 2% of TKR patients (7% of the UKR patients) could kneel. Post-operatively, the patients’ kneeling ability improved with 21% for the mobile bearing, 32% of fixed bearing UKR patients. The TKR patients kneeling ability was 13% of the mobile, 26% of fixed bearing patients were able to kneel with little or no difficulty. In all groups the stated kneeling ability was poor with less than 50% of any group being able to kneel with ease or only minor difficulty.

Conclusion: Those undergoing UKR appeared to perform better than those with a TKR. None of the forms of knee replacement used resulted in good kneeling ability, though this function was improved by arthroplasty in all groups. Mobile bearing inserts


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 580 - 580
1 Aug 2008
Hassaballa M Bevan D Porteous A
Full Access

Introduction: Force plate analysis of contact areas and pressure has been used in the fields of podiatry and foot surgery. We used this tool in assessing normal subjects and knee replacement patients kneeling.

Aim: We analysed contact areas and pressures over the front of the knee during different kneeling positions.

Methods: Twenty three normal subjects and 33 knee replacement patients were included in this study. The patients were selected according to age and kneeling ability and the absence of involvement of other joints. They had unilateral or bilateral Total (TKR) or Unicompartmental knee replacements (UKR).

Target points were identified on the plate and patients were asked to place their tibial tuberosity on the target sites.

Patients and normal subjects’ data of load, contact area and pressure were recorded with knee at 90 degrees. A second reading was taken with subjects kneeling in their maximum flexion comfortable position. Foot position during kneeling was recorded in each case.

Results: Average age was 48.3 years for the normal group and 65.5.2 for the replaced knee group. Average range of motion was 141 degrees for the normal group and 115 degrees for the replaced knees group.

In the normal group, there was a significant positive correlation between body mass and kneeling load at both 90 degrees and maximum flexion. Kneeling pressure was never identical in both knees in all groups. There was no significant difference of peak pressures and contact areas between the normal and UKR group.

The angle of flexion affected the contact pressures as going from 90 degrees to higher flexion with the body weight still actively supported increases contact pressure, which then dropped to lowest level in maximum flexion when the body weight was supported by the calf. Peak loads were usually in the region of the tibial tuberosity.

Conclusion: Kneeling may be a sided activity with each individual having a dominant knee. The UKR group showed more normal kinematics in comparison with the TKR group.

Maximum contact pressures decreased in knees able to achieve full flexion. As kneeling flexion angle increases, the contact area decreases and while the thigh is off the calf and the peak pressure increases. Contact pressure dropped to below 90 degrees level whenever full flexion was achieved.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 574 - 574
1 Aug 2008
Barton T White S Porteous A Mintowt-Czyz W Newman J
Full Access

Purpose: To review long-term outcome following knee arthrodesis, and compare this with patient outcome following revision knee arthroplasty.

Methods: Case notes and radiographs of patients who underwent arthrodesis using the Mayday nail were reviewed retrospectively for evidence of clinical and radiological union. Patients also completed an SF12 health survey and Oxford knee score in the form of postal questionnaires. Each patient was matched with patients who had undergone revision knee arthoplasty and the outcomes were compared.

Results: 19 patients were reviewed who underwent knee arthrodesis using a Mayday nail in two centres between 1993 and 2004. 18 cases had united clinically and radiologically with one case lost to follow-up. Mean SF12 scores of patients following knee arthrodesis indicated severe physical (28.8) but only mild mental (43.3) disabilities. The mean Oxford knee score in this group was 41.0. These results were comparable with matched patients following revision knee arthroplasty who scores 27.2 (physical) and 41.1 (mental) on the SF12, and a mean of 38.8 on the Oxford knee score.

Conclusion: Outcome scores following knee arthrodesis were similar to those following revision knee arthroplasty making it an option worth considering in selected patients requiring revision surgery.

Discussion: The Mayday nail provides a method of knee arthrodesis with a high union rate and an acceptable complication rate. Outcome scores following arthrod-esis were not dissimilar to those following revision total knee replacement. These results suggest that knee arthrodesis may be considered as an acceptable alternative to complex knee revision surgery.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 580 - 580
1 Aug 2008
Hassaballa M Porteous A Newman JH
Full Access

Introduction: There is an impression among Orthopaedic surgeons that mobile bearing knee replacement has a better functional outcome than fixed bearing knee replacement. Since kneeling demands a high level of function after knee replacement this study was undertaken to see if mobile bearings in either total or unicompartmental replacement conferred an advantage.

Methods: A prospective randomised study of 207 TKR patients receiving the same prosthesis (Rotaglid , Corin, UK) was performed. Patients were randomised into a mobile bearing group (102 patients with a mean age of 53 years) and a fixed bearing group (105 patients with a mean age of 55 years).

Data was also prospectively collected on 215 UKR patients who received the same Unicompartmental implant (AMC, Uniglide, Corin, UK). One hundred and thirty six patients (Mean age: 62 yrs) had a mobile insert and 79 (mean age: 65 yrs) a fixed insert.

All patients completed the Oxford Knee Questionnaire preoperatively as well as at 1 and 2 years postoperatively. Their stated kneeling ability and total scores were analysed with a perfect score for kneeling ability being 4 and 48 the maximum total score.

Results: In all groups both the kneeling ability and the total scores improved markedly from their preoperative state. At two years the total score for the fixed bearing devices was marginally better than for the mobile (Rotaglide 36;31 and Uniglide 37;33)

There was a more striking difference with respect to kneeling ability with the fixed- bearing variants performing better, (Rotaglide 1.4; 0.9 and Uniglide 1.9; 1.4), However, the greatest difference was between the UKR and TKR groups (UKR 1.7; TKR 1.2). Pre-operatively less than 2% of TKR patients (7% of the UKR patients) could kneel. Post-operatively, the patients’ kneeling ability improved with 21% for the mobile bearing, 32% of fixed bearing UKR patients.

The TKR patients kneeling ability was 13% of the mobile, 26% of fixed bearing patients were able to kneel with little or no difficulty. In all groups the stated kneeling ability was poor with less than 50% of any group being able to kneel with ease or only minor difficulty.

Conclusion: Those undergoing UKR appeared to perform better than those with a TKR. None of the forms of knee replacement used resulted in good kneeling ability, though this function was improved by arthroplasty in all groups. Mobile bearing inserts did not confer any advantage with respect to kneeling and in fact performed worse with regard to this particular knee function.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 327 - 327
1 Jul 2008
Mutimer J Gillespie G Lovering A Porteous A
Full Access

The aim of this study was to measure intra-articular gentamicin levels at the 2nd stage revision following the use of an antibiotic impregnated articulating spacer.

Infected total knee replacements are a cause of considerable morbidity often requiring revision in two stages. Rings of bone cement, cement moulds and spacer devices are available for use following the initial debridement and removal of infected metalwork. The availability of antibiotic impregnated articulating spacers are potentially attractive to achieve a high local dose of antibiotic and to maintain a good range of movement.

Seven patients underwent a two stage revision of their total knee replacements. Following the initial debridement an antibiotic impregnated articulating spacer was cemented in place. At the 2nd stage revision a perioperative joint aspirate and blood sample was taken and gentamicin levels measured. The range of movement was assessed.

The average gentamicin levels were 0.72mg/l (0.24 – 2.36mg/l). A good range of movement was maintained in all cases. At these levels the gentamicin would be therapeutic.

Antibiotic impregnated articulating spacers possess several potential advantages to the revision knee surgeon by helping maintain the range of movement and provide local release of antibiotics. Their use should be considered in such cases.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 256 - 257
1 May 2006
Hassaballa M Weal A Porteous A Newman J
Full Access

Purpose: This study was carried out to compare the alteration in skin sensation following midline, medial and short medial incisions for knee replacement.

Method: 88 patients with 102 replaced knees were examined for altered skin sensation over the front of the knee, all were at least 18 months from their knee replacement. Twenty-one knees had a medial incision, 38 a midline incision and 43 a short medial incision for UKR.

A scale of −2 to +2 was used to measure different degrees of skin hypo or hyperaesthia. A purpose-designed grid, designed to fit different knee sizes, was used to record sensations. A computer programme was created to record all patients’ data including the length and shape of the incision in relation to anatomical landmarks.

A parallel histological study was carried out on 18 skin specimens taken from the 2 standard incisions. The specimens were prepared and stained for nerve endings. The number of nerve endings in each incision was calculated.

Results Histologically, less cutaneous nerve endings were seen in specimens from midline incisions than medial incisions.

Discussion: Altered skin sensation is unpleasant to many patients at least initially and may affect function especially kneeling. The midline line incision seems to produce less dermal parasthesia than the medial incision, this probably relates to both the wound position and the density of nerve endings. As expected, the length of incision correlated with the area of numbness when comparing short and long medial incisions.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 348 - 348
1 Sep 2005
Borrill J Porteous A Seddon-Porteous J Morris H
Full Access

Introduction and Aims: Cold therapy is known to reduce pain and swelling after surgical procedures on the knee. We hypothesised that if cold therapy is started earlier, then there would be a reduction in pain and swelling in patients undergoing arthroscopic anterior cruciate ligament [ACL] reconstruction.

Method: We prospectively randomised 40 patients undergoing arthroscopic ACL reconstruction with hamstring autograft, to receive either room temperature [19° C] or cold [4° C] arthroscopy irrigation fluid. Patients were then assessed over the following seven days, with regard to pain [measured on a visual analogue scale], and swelling [measured with limb girth at four points around the knee].

Results: Pain scores were consistently reduced in the cold fluid group compared to the room temperature group throughout the post-operative period, and this difference was significant [p< =0.05] from six hours until seven days post-operatively. At day seven, the swelling measured at 5cm below the joint and 5cm above the joint were significantly lower in the cold group compared with the room temperature group. Drainage from the intra-articular drain was significantly lower in the cold group.

Conclusion: The use of cold irrigation fluid is a simple and safe measure by which pain and swelling (at day 7) can be reduced in the early post-operative period for arthroscopic ACL reconstruction.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 340 - 341
1 Sep 2005
Hassaballa M Porteous A Newman J
Full Access

Introduction and Aims: Kneeling is an important function of the knee joint but little information is available on ability to kneel after different types of knee arthroplasty. We aimed to assess patients’ kneeling ability pre- and post-operatively after uni-compartmental, patellofemoral and total knee arthroplasty (UKR, PFR, TKR) and to objectively examine: kneeling ability, factors that affect it and whether this ability differed from the patient’s perception.

Method: In 253 knee arthroplasty cases, we prospectively analysed the ability to kneel pre-operatively, and post-operatively at one and two years using the relevant section of the Oxford Knee Score questionnaire. One hundred and twenty-two post-operative patients (38 TKR, 53 UKR, 31 PFR) were then examined to assess their actual kneeling ability.

Results: Patients’ perception of their kneeling ability prior to surgery was poor in all three groups (mean score 0.7 out of 4) and improved in all groups after surgery (mean score at two years 1.46 out of 4). Perceived kneeling ability was best in UKR and worst in PFR (P< 0.001). Perceived kneeling ability improved most in the first year post-operatively, but continued to improve between one and two years although the final kneeling function was still not good. When examined, only 37% of patients thought they could kneel, whereas 81% were actually able to kneel (P< 0.001). Ability to kneel was significantly better than perceived ability for all prosthesis types (P< 0.001). Kneeling ability was better in men and associated with an increased range of movement (P< 0.001).

Conclusion: Kneeling ability is poor prior to knee arthroplasty and improves up to two years post-operatively, though it is still perceived to be poor, but can be improved with rehabilitation. UKR gave better kneeling ability than PFR or TKR. Patient-centred questionnaires do not accurately document kneeling ability after knee arthroplasty.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 446 - 446
1 Apr 2004
Porteous A Hassaballa M Newman J
Full Access

Aim: The aim of this study was to evaluate the functional results and ease of performing revision surgery after a primary unicompartmental arthroplasty versus primary total knee arthroplasty.

Method: 114 revision TKRs had data collected prospectively as part of our unit’s Knee Database. 45 were revisions of UKR’s and 79 revisions of TKR’s. This data included Bristol Knee Scores (BKS), reason for revision, use of implant augments and bone graft. Measurements were also made of the ability to restore joint-line after revision.

Results: In both groups there was a significant improvement in BKS post-operatively. In the UKR group the commonest reason for revision was progression of disease, while in the TKR group it was aseptic loosening. Bone graft was required in significantly fewer UKR cases (20% vs 40%, P< 0.05). Distal femoral augments were used in 45% of the TKR revisions but in none of the revisions from UKR. The joint line was elevated in a significantly higher proportion of revision from TKR cases versus revision from UKR cases (P< 0.001). Revisions from UKR had higher Total BKS and Functional BKS score than revisions from TKR.

Conclusions: Revision TKR after a primary UKR requires less bone graft, fewer augments, restores the joint line more frequently and gives improved functional results over revisions after primary TKR.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 472 - 473
1 Apr 2004
Bartlett R Porteous A
Full Access

Introduction The aim of this study was to examine the flexion stability of posterior stabilised (PS) compared with deep dished (DD) tibial inserts in PCL sacrificing total knee arthroplasty using posterior stress radiography.

Methods Kneeling posterior stress radiographs at 90° of flexion were taken pre and post-operatively in 36 knees undergoing primary arthroplasty with PCL resection (26 DD and 10 PS implants). Sagittal plane tibial translation was measured.

Results The deep dish inserts all showed posterior displacement (mean: −5.1 mm, range: −2 to −12 mm). The posterior stabilised implants were all displaced anteriorly (mean: +6.7 mm, range: +3 to +12 mm). The difference in translation was highly significant (P< 0.0001). There was a strong correlation between implant and position of the tibia (R = 0.86). In seven patients comparison was possible between a DD component in one knee and a PS implant in the other. There was a mean post-operative side to side difference of 11 mm (range: 5 to 21 mm).

Conclusions This study discriminates between two implant types on stress x-rays. The posterior tibial displacement in the DD group suggests that this implant does not provide enough posterior flexion stability to compensate for the PCL resection. The anterior translation in the PS group has implications for the design and wear of the post as well as advice to patients about possibly avoiding kneeling in this PS design.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 337 - 337
1 Mar 2004
Mo H Porteous A Newman J
Full Access

Aim: To assess the functional results of revision TKR with the PFC/TC3 system, and to correlate this with the reasons for revision and restoration of joint height. Method: 153 patients underwent revision TKR using the PFC/TC3 system. Data was prospectively collected (using the Bristol Knee Score) pre-operatively and at a mean of 4.2 years post-revision. 43 revisions were for infection and 81 revisions were for aseptic loosening. Measurements of the joint height were made pre and post-operatively using FiggieÔs method and were divided into 3 groups: lower by more than 5mm, restored and elevated more than 5mm. Use of distal augments and polyethylene thickness were recorded. Results: The mean pre-op function score was 12 and post-operatively was 19 for the infection group and 20 for the aseptic loosening group. Revision after initial UKR gave a mean score of 21, while revision after TKR gave a mean score of 18 (max 27). Knees in which the joint line was elevated by more than 5 mm had a mean score of 17 while those where the joint line was restored had a mean score of 19. Recent increasing use of distal augments improved the joint line and results. Conclusion: revision using the PFC/TC3 system produced acceptable medium term functional results and good survival. Better restoration of joint line and functional results were achieved by distal femoral rather than proximal tibial augmentation.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 247 - 248
1 Mar 2004
Porteous A Bartlett J
Full Access

Aim: To examine the flexion stability of posterior stabilised (PS) vs deep dished (DD) tibial inserts, in PCL sacrificing total knee arthroplasty using posterior stress radiography. Methods: A simple jig was designed to allow kneeling posterior stress radiographs (at 90 degrees flexion) to be taken. This method was used to take pre and post-operative radiographs in 36 knees undergoing primary arthroplasty with PCL resection (26 DD and 10 PS implants). Sagittal plane tibial translation was measured. Results: The DD inserts all showed posterior displacement (mean: −5.1 mm, range: −2 to −12mm). The PS implants were all displaced anteriorly (mean: +6.7mm, range: +3 to +12mm). The difference in translation was highly significant (P< 0.0001). There was a strong correlation between implant and position of the tibia (R=0.86). In 7 patients, comparison was possible between a DD component in one knee and a PS implant in the other. There was a mean post-operative side-to-side difference of 11mm (range: 5 to 21mm). Conclusions: This study validates a simple new method for flexion stress x-rays (by accurately discriminating between the two implant types). The posterior tibial displacement in the DD group suggests that this implant does not provide enough posterior flexion stability to compensate for the PCL resection. The anterior translation in the PS group has implications for the design and wear of the post, as well as advice to patients about possibly avoiding kneeling in this PS design.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 55 - 55
1 Jan 2003
White SP Porteous A Newman JH Mintowt-Czyz W
Full Access

The aim of this study was to demonstrate the effectiveness of a customised coupled arthrodesis nail.

Knee arthrodesis is now infrequently performed and is usually reserved as a salvage for infected Joint arthroplasty or occasionally for intractable pain. Many methods have been used. Recently locked intramedullary coupled nails have gained in popularity. To deal with all size combinations a large inventory is required. We wish to report our series using a customised implant and to compare the outcome with other methods of knee arthrodesis.

Nine patients underwent arthrodesis using this implant, six following infected arthroplasty, two for intractable anterior knee pain and following trauma. Comparison was made with 17 arthrodeses performed since 1993 using external fixation (8), plates (4), and long K-nails (5). Union was achieved in nine patients (100%) at a mean time of 10 months using the customised implant. There were no complications despite early weight-bearing. No further procedures were required. This contrasted with a union rate of 65% with a 76% complication rate using alternative techniques. Seventy six percent of this second group required a further operative procedure.

We conclude that a customised coupled intramedullary nail can give excellent stability allowing early weight-bearing, and results in a high union rate with minimal post-operative complications. The differences in need for further surgery and occurrence of complications were statistically significant (p< 0.001), and differences in in-patient stay and non-union rate were also significant (p< 0.05) using Fisher’s exact test.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 55 - 55
1 Jan 2003
Hassaballa M Porteous A Newman JH
Full Access

The aim of this study was to analyse the kneeling ability of patients before and at one and two years after total (TKR), unicompartmental (UKR) and selective patellofemoral (PFR) knee arthroplasty, for osteoarthritis. Method: Data was prospectively collected on 253 knees, which underwent either TKR, UKR or PFR. A kneeling score was obtained by analysis of the relevant section of the Oxford Knee Score questionnaire. Scores were obtained pre-operatively and at 1 and 2 years post-operatively (minimum score 0, maximum 4). Absolute values and change following arthroplasty were recorded. Correlations with pain and other knee functions were also made.

Results: Kneeling ability prior to surgery was poor in all three groups (mean score 0.7 out of 4) and improved significantly after surgery (mean score at one year 1.13 and at two years 1.46 out of 4) (P< 0.001). Kneeling ability at 1 year differed significantly with operation type (p = 0.02). Kneeling ability improved most in the first year post-operatively but continued to improve between one and two years although the final function was still not good. Kneeling ability was best in UKR and worst in PFR, with the difference between these prostheses being statistically significant (P< 0.001).

Conclusion: Kneeling ability in osteoarthritic knees is poor but improves with arthroplasty. However, the majority of patients will still have difficulty kneeling.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 319 - 319
1 Nov 2002
Hassaballa M Porteous A Newman JH
Full Access

Aim: To assess the functional results of revision TKR with the PFC/TC3 system, and to correlate this with the reasons for revision and restoration of joint height.

Method: One hundred and fifty three patients underwent revision TKR using the PFC/TC3 system. Data was prospectively collected (using the Bristol Knee Score) pre-operatively and at a mean of 4.2 years post-revision. Forty three revisions were for infection and 81 revisions were for aseptic loosening. Measurements of the joint height were made pre and post-operatively using Figgie’s method and were divided into three groups: lower by more than 5mm, restored and elevated more than 5mm. Use of distal augments and polyethylene thickness were recorded.

Results: The mean pre-op function score was 12 and post-operatively was 19 for the infection group and 20 for the aseptic loosening group. Revision after initial UKR gave a mean score of 21, while revision after TKR gave a mean score of 18 (max 27). Knees in which the joint line was elevated by more than 5 mm had a mean score of 17 while those where the joint line was restored had a mean score of 1 9. Recent increasing use of distal augments improved the joint line and results.

Conclusion: Revision using the PFC/TC3 system produced acceptable medium term functional results and good survival. Better restoration of joint line and functional results were achieved by distal femoral rather than proximal tibial augmentation.