CLINICAL OUTCOME OF TKA PERFORMED WITH PATIENT SPECIFIC INSTRUMENT TECHNOLOGY (PSI) – WITH MINIMUM ONE YEAR FOLLOW-UP

The South West Orthopaedic Club (SWOC)



Abstract

Total knee arthoplasty (TKA) remains a standard treatment for advanced knee arthritis. The aim of the procedure is to restore function and relieve pain ideally for the rest of patient's life. Patient matched templating (PMT) or patient specific instrumentation (PSI) is a recent development for alignment of TKA components that uses disposable guides. The users of PSI claim it to be the optimum balance of new technology and conventional technique by reducing the complexity of conventional alignment and sizing tools.

To assess the clinical and radiological outcome of Primary TKA done with PSI.

More than 200 cases of TKA have been done in our unit using PSI and we analysed the radiographic outcome of these cases postoperatively. We also reviewed the clinical outcome of 103 patients with 1 year and 43 patients with 2 year follow-up. Data was collected prospectively: pre-operatively and at 1 year and 2 years post-operatively including Oxford knee score (OKS), WOMAC and American knee society score (AKS). Standard AP and lateral films were done pre-operatively and post-operatively.

Mean age was 66 years. There were 56 female and 47 male patients. Mean post-operative angles on standard films were: Alpha = 95.6, Beta = 88.4, Saggittal femur = 3.4 and Saggittal tibia = 90.8. Of the 103 cases with 1 year follow-up, there was significant improvement in all clinical outcome scores. Mean OKS improved from 18 to 39 at 1 year and remained the same at 2 years, WOMAC improved from 40 to 18 in both 1 and 2 years post-op. AKS Total improved from 79 to 173 at 1 year and 170 at 2 years.

Performing TKA using PSI is safe and provides good radiological alignment in the coronal and sagittal plane. Significant improvement in outcome scores were seen at one and two year follow up and reached levels that compared favourably with other reported series of TKA outcome from our unit.