Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively.
The posterior-stabilized knee prosthesis is designed specifically to provide the posterior stability to a knee arthroplasty when PCL is deficient or has to be sacrificed. Posterior dislocation of such prosthesis is rare but dreaded complication. There are several causes of postoperative dislocation such as malposition of the prosthesis, preoperative valgus deformity, a defect of the extensor mechanism and overwidening of the flexion gap. Posterior-stabilized rotating-platform mobile-bearing knee implants have been widely used to further improve the postoperative range of motion by incorporation of the post and cam mechanism to improve the posterior roll back during flexion and to overcome the wear and osteolysis problems due to significant undersurface micromotion of posterior-stabilized fixed-bearing knees. But, spin-out or rotatory dislocation of the polyethylene insert can occurs as result of excessive rotation of the rotating platform accompanied by translation of the femur on the tibia after mobile-bearing total knee arthroplasty, but that is very rare. Here, authors describe an unusual case of acute 180° rotatory dislocation of the rotating platform after posterior dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty. A 71-year-old male with knee osteoarthritis underwent a TKRA using posterior-stabilized mobile-bearing prosthesis. The posterior dislocation of the total knee arthroplasty occurred 5 weeks postoperatively(Fig. 1). We underwent closed reduction of posterior dislocated total knee arthroplasty resulting in a complete 180° rotatory dislocation of the rotating platform (Fig. 2). He was treated with open exploration and polyethylene exchange with a larger component. This case illustrates that dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty can occur with valgus laxity, cause 90° spin-out of the polyethylene insert and closed reduction attempts may contribute to complete 180° rotatory dislocation of the rotating platform. Special attention needs to be paid to both AP and lateral view to ensure that the platform is truly reduced and not just rotated 180° as was in this case.
We report the incidence and intensity of persistent
pain in patients with an otherwise uncomplicated total ankle replacement
(TAR). Arthroscopic debridement was performed in selected cases
and the clinical outcome was analysed. Among 120 uncomplicated TARs, there was persistent pain with
a mean visual analogue scale (VAS) of 2.7 (0 to 8). The intensity
of pain decreased in 115 ankles (95.8%). Exercise or walking for
more than 30 minutes was the most common aggravating factor (62
ankles, 68.1%). The character of the pain was most commonly described
as dull (50 ankles, 54.9%) and located on the medial aspect of the
joint (43 ankles, 47.3%). A total of seven ankles (5.8%) underwent subsequent arthroscopy.
These patients had local symptoms and a VAS for pain ≥ 7 on exertion.
Impingement with fibrosis and synovitis was confirmed. After debridement,
the median VAS decreased from 7 to 3 and six patients were satisfied.
The median VAS for pain and the American Orthopaedic Foot and Ankle
Society score of the ankles after debridement was similar to that
of the uncomplicated TARs (p = 0.496 and p = 0.066, respectively). Although TAR reduces the intensity of pain, residual pain is
not infrequent even in otherwise uncomplicated TARs and soft-tissue
impingement is the possible cause. Cite this article:
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
 0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range. Bone mineral density measured
at the proximal femur and the position of the screws in the subchondral
region, correlated with slight progressive radial shortening, which
was not clinically relevant. Volar locking plating of distal radial fractures is a reliable
form of treatment without substantial late displacement. Cite this article:
The purpose of this study was to measure the
radiological parameters of femoral component alignment of the Oxford
Phase 3 unicompartmental knee replacement (UKR), and evaluate their
effect on clinical outcome. Multiple regression analysis was used
to examine the relative contributions of the radiological assessment
of femoral component alignment in 189 consecutive UKRs performed
by a single surgeon. The American Knee Society scores were compared
between groups, defined as being within or outside recommended tolerances
of the position of the femoral component. For the flexion/extension
position 21 UKRs (11.1%) lay outside the recommended limits, and for
posterior overhang of the femoral component nine (4.8%) lay outside
the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest
canal distance from the distal femoral entry point of the alignment
jig and coronal entry-point position had significant effects on
the flexion/extension position. Pre-operative HKA angle had a significant
influence on posterior overhang of the femoral component. However,
there was no significant difference in American Knee Society scores
relative to the position of the femoral component.
No study compared the clinical results of the posterior-stabilized mobile-bearing knee with those of nonposterior-stabilized mobile-bearing knee in the same patients. The purpose of this study was to examine whether the clinical and radiographic results, range of motion, patients satisfaction, and complication rates would be better in the knees with a posterior-stabilized mobile-bearing knee than in the knees with a nonposterior-stabilized mobile-bearing knee. One hundred and fourteen patients (mean age, 67.9 years) received a nonposterior-stabilized mobile-bearing knee prosthesis in one knee and a posterior-stabilized mobile-bearing knee prosthesis in the contralateral knee. Seven patients were men, and 107 were women. At the time of each follow-up (mean, 7.3 years; range, seven to 7.6 years), the patients were assessed clinically and radiographically.Background
Methods
Total Knee Arthroplasty (TKA) is a durable procedure which allows most patients to achieve a satisfactory functional level, but there can be instability under stressful conditions. Instability is one cause of early revision, often due to misalignment or inadequate ligament balancing. Persistent instability may cause elevated polyethylene wear. Lower levels of instability may cause patient discomfort with certain stressful activities. Hence quantifying instability may have an important role in the functional evaluation of TKA. Several previous studies showed that accelerometers have advantages in kinematic studies including low cost, ease of application, and application to any activity. The aim of this study was to demonstrate the use of an accelerometer attached to the anterior of the tibia, as an evaluation of knee stability of TKA patients. It was postulated that accelerations between TKAs and normal controls will be different, which could indicate abnormal TKA kinematics involving instability, especially for high intensity activities. We tested 38 TKA knees in 27 patients, in the age range of 50–80 years, with a minimum follow up of 6 months; and 25 knees in 16 shoulder patients, who had no known knee pathology as age-matched controls. A tri-axial accelerometer was firmly attached to the anterior proximal tibia to measure 3-axis accelerations with a sample rate of 100 Hz. Four activities were tested; Starting with the test leg, walk 3 steps then come to a sudden stop Take one step forward with the non-tested leg and make a tight 90∗∗∗∗∗ turn towards the non- tested knee direction Sit down for 3–4 seconds then stand back up Step up on a 7″ inches high box with the test leg, followed by the non-test leg. Then step down from the box with the test leg, followed by the non-test leg. During the activities, the patients responded to a questionnaire on instability and pain for each activity. For each test at the time of foot impact, there was a high/low peak acceleration, the peak-to-valley being taken as the indicator. The mean total magnitude of the acceleration was compared between the TKA and control groups in the anterior-posterior direction using the Student's t-test. Statistical significance was at p-value < 0.05.INTRODUCTION
METHODS & MATERIALS
Despite many claims of good wear properties following
total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral
component, there are conflicting clinical results. We hypothesised
that there would be no difference in either the mid-term clinical
and radiological outcomes or the characteristics of the polyethylene
wear particles (weight, size and shape) in patients using an OxZr
or cobalt-chrome (CoCr) femoral component. In all 331Â patients underwent
bilateral TKR, receiving an OxZr femoral component in one knee and
a CoCr femoral component in the other. The mean follow-up was 7.5
years (6 to 8). Following aspiration, polyethylene wear particles
were analysed using thermogravimetric methods and scanning electron
microscopy. At the most recent follow-up, the mean Knee Society
score, Western Ontario and McMaster Universities Osteoarthritis
Index score, range of movement and satisfaction score were not significantly
different in the two groups. The mean weight, size, aspect ratio
and roundness of the aspirated wear particles were similar for each
femoral component. Survivorship of the femoral, tibial and patellar
components was 100% in both groups. In the absence of evidence of an advantage in the medium term
we cannot justify the additional expense of an OxZr femoral component.
It has been suggested that the wear of ultra-high molecular weight polyethylene (UHMWPE) in total hip replacement is substantially reduced when the femoral head is ceramic rather than metal. However, studies of alumina and zirconia ceramic femoral heads on the penetration of an UHMWPE liner in vivo have given conflicting results. The purpose of this study was to examine the surface characteristics of 30 alumina and 24 zirconia ceramic femoral heads and to identify any phase transformation in the zirconia heads. We also studied the penetration rate of alumina and zirconia heads into contemporary UHMWPE liners. The alumina heads had been implanted for a mean of 11.3 years (8.1 to 16.2) and zirconia heads for a mean of 9.8 years (7.5 to 15). The mean surface roughness values of the explanted alumina heads (Ra 40.12 nm and Rpm 578.34 nm) were similar to those for the explanted zirconia heads (Ra 36.21 nm and Rpm 607.34 nm). The mean value of the monoclinic phase of two control zirconia heads was 1% (0.8% to 1.5%) and 1.2% (0.9% to 1.3%), respectively. The mean value of the monoclinic phase of 24 explanted zirconia heads was 7.3% (1% to 26%). In the alumina group, the mean linear penetration rate of the UMWPE liner was 0.10 mm/yr (0.09 to 0.12) in hips with low Ra and Rpm values (13.22 nm and 85.91 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.13 mm/yr (0.07 to 0.23) in hips with high Ra and Rpm values (198.72 nm and 1329 nm, respectively). This difference was significant (p = 0.041). In the zirconia head group, the mean linear penetration rate of the UHMWPE liner was 0.09 mm/yr (0.07 to 0.14) in hips with low Ra and Rpm values (12.78 nm and 92.99 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.12 mm/yr (0.08 to 0.22) in hips with high Ra and Rpm values (199.21 nm and 1381 nm, respectively). This difference was significant (p = 0.039). The explanted zirconia heads which had a minimal phase transformation had similar surface roughness and a similar penetration rate of UHMWPE liner as the explanted alumina head.
Although total knee arthroplasty (TKA) has been a reliable procedure providing durable pain relief, polyethylene (PE) wear remains a major limitation of the long-term success of TKA. One potential method of lowering PE wear in TKA is to use oxidized zirconium (OxZr)-bearing surface. Although wear simulating testing of an OxZr counter surface of femoral component produced less PE wear and fewer particles than did cobalt-chrome (Co-Cr) counter surface of femoral component [1–4], this finding has not been demonstrated in vivo to our knowledge. We measured in vivo PE wear by isolating and analyzing PE wear particles in synovial fluid from wellfunctioning TKA [5]. The purpose of the current study was to determine the size, shape, and amount of PE wear particles isolated from synovial fluid of patients who underwent a bilateral simultaneous TKA prosthesis, but different materials of femoral components. We performed a bilateral simultaneous TKA in 100 patients (200 knees) who received an OxZr femoral component in one knee and a Co-Cr femoral component in the other. Mean age was 55.6 (44–60) years. Synovial fluid was obtained from 28 patients (56 knees) who had undergone a simultaneous bilateral TKA under completely sterile conditions at one or two years after the operation. Randomization to an OxZr or Co-Cr femoral component was accomplished with use of a sealed study number envelope, which was opened in the operating room before the skin incision had been made. After the opening the randomization envelope, the first knee received prosthesis indicated by the envelope (OxZr or Co-Cr component) and the contralateral (second TKA) knee received the other prosthesis (OxZr or Co-Cr component). All operations were performed by one surgeon using the same design of total knee prosthesis: Genesis II (Smith and Nephew, Memphis, Tennessee). Only the material of the femoral component differed between two groups. The preoperative diagnosis was osteoarthritis in all patients. Preoperative and post operative KS and HSS knee scores, KS functional scores and UCLA activity scores were evaluated. The amount of polyethylene wear particles in the aspirated synovial fluid sample was analyzed by thermogravimetic analysis (TGA) using a TGA instrument (TGA/SDTA 84le model, Mettler Toledo CO., Greifensee, Switzerland). The weight of the sample solution was measured before and after removing the organic content by heating the sample solution. The sample solution was casted onto petri dishes. The petri dish was covered and kept in a dry oven at 60°C for 2 days. While the sample solution was kept in a dry oven for 2 days, a small hole was made on the cover of the petri dish to allow water to evaporate slowly for 2 days. After this procedure, the cover of petri dish was removed and TGA sample was dried at 60°C for another 2 days. After the sample was completely dried out, the dried sample was measured using analytical balance. TGA was used to determine the weight change profiles of polyethylene subject to heating under a nitrogen atmosphere. The nitrogen flow rate was kept constant at 50mL per minute. TGA data were taken at heating rate as 5°C per minute in the temperature range of 20° to 1000°C. The weight loss data were recorded as a function of time and temperature using special software in computer. When the temperature reached to the point of decomposition of the sample, the sample started to lose weight. By calculating the weight of the sample around the temperature which led to start to decomposition, real amount of polyethylene in the sample was measured. The size and shape of PE particles were examined using scanning electron microscopy (JSH-6360A model, Jeol Co., Tokyo, Japan). The samples were coated using a platinum sputtering machine for 20 sec. ANOVA, nonparametric chi square test, nonpaired t-test and Mann-Whitney U-test were used for statistical analyses. Differences of P<
0.05 were considered statistically significant. Mean preoperative KS (27.5 vs 27.2 points) scores, HSS (51.1 vs 51.2 points) knee scores, KS functional scores (55.4 vs 55.4 points) and UCLA activity scores (2.8 vs 2.8 point) were not significantly different between two groups. Mean postoperative KS (93 vs 92 points), HSS knee scores (90 vs 89 points), KS functional scores (78 vs 78 points), and UCLA activity scores (7.8 vs 7.8) were not significantly different. Mean weight of the polyethylene particles was 0.0219 g (SD, 0.0058) in the Co-Cr femoral component groups and it was 0.0214 g (SD, 0.005) in the OxZr group. This difference was not significant (P=0.711139, paired t-test). The size of particles was not different between the two groups. Also, shape of particles was not different between the two groups. Under the condition and the duration of this study in this specific group of patients, TKA with OxZr or Co-CR femoral knee component had excellent clinical and radiographic outcomes with no osteolysis. While the wear simulator test in vitro demonstrated significant decrease in PE particles in the knees with an OxZr femoral component, our study in vivo revealed that total particle weight, size, and shape of PE wear particles were similar in the knees with an OxZr femoral component and in those with a Co-Cr femoral component.
We aimed to analyze the clinical results of the patients according to joint line change who underwent navigation assisted cruciate ligament retention type mobile bearing total knee arthroplasty. From September 2004 to January 2006, cruciate ligament retention type mobile bearing total knee arthroplasties using navigation system(Orthopilot®, Aesculap) were performed for 50 knees in 45 patients (2 men, 43 women). The mean follow up period was 46(39~55) months and the mean age was 65. There was one case with rheumatoid arthritis and all other were degenerative arthritic cases. All surgeries were performed using navigation system. Proximal tibia resection was performed at the sclerotic level of medial tibial plateau. The distance from the lowest point of lateral tibial plateau (registered point) to the proximal resection plane was measured. Clinical outcome were compared between joint line elevation with more than 3 mm(20cases) and less than 3mm (30cases). The mean joint line elevation was 1.93 mm (range −1~5mm). There were no significant difference in the clinical results according to the joint line change (p>
0.05). It may be suggested that the change of joint line in the range of −1 to 5mm in cruciate ligament retention type mobile bearing total knee arthroplasty result in satisfactory clinical outcome.
As the proximal femoral bone is generally compromised in failed hip arthroplasty, achievement of solid fixation with a new component can be technically demanding. Recent studies have demonstrated good short-term clinical results after revision total hip arthroplasty using modular distal fixation stems, but, to our knowledge, none have included clinical follow-up of greater than 5 years. The purpose of this study was to report the clinical and radiographic outcomes assessed 5 to 10 years following revision total hip arthroplasty with a modular tapered distal fixation stem. We retrospectively evaluated 50 revision total hip arthroplasties performed using a modular tapered distal fixation stem Between December 1998 and November 2003. There were 15 men (16 hips) and 34 women (34 hips) with a mean age of 59 years (range, 36 to 80 years). The index operation was the first femoral revision for 46 hips, the second for 3 hips, and the fifth for 1 hip. According to the Paprosky classification, 5 femoral defects were Type II, 31 were Type IIIA, and 14 were Type IIIB. An extended trochanteric osteotomy was carried out in 24 (48%) of the 50 hips. Patients were followed both clinically and radiographically for a mean of 7.2 years. The mean Harris hip score improved from 54 points preoperatively to 94 points at the time of the latest follow-up. The mean stem subsidence was 1.5mm. Three stems subsided more than 5 mm, but all have stabilized in their new positions. During follow-up, a total of 4 hips required additional surgery. One hip had two-stage re-revision due to deep infection, one had liner and head exchange for alumina ceramic head fracture, and the other two underwent isolated cup re-revision because of aseptic cup loosening and recurrent dislocation, respectively. No repeat revision was performed due to aseptic loosening of the femoral component. Complications included 6% intraoperative fractures, 4% cortical perforations, and 4% dislocations. There were no stem fractures at the modular junction. The medium-term clinical results and mechanical stability obtained with this modular tapered distal fixation stem were excellent in these challenging revision situations with femoral bone defects.
A number of causes have been advanced to explain the destructive discovertebral (Andersson) lesions that occur in ankylosing spondylitis, and various treatments have been proposed, depending on the presumed cause. The purpose of this study was to identify the causes of these lesions by defining their clinical and radiological characteristics. We retrospectively reviewed 622 patients with ankylosing spondylitis. In all, 33 patients (5.3%) had these lesions, affecting 100 spinal segments. Inflammatory lesions were found in 91 segments of 24 patients (3.9%) and traumatic lesions in nine segments of nine patients (1.4%). The inflammatory lesions were associated with recent-onset disease; a low modified Stoke ankylosing spondylitis spine score (mSASSS) due to incomplete bony ankylosis between vertebral bodies; multiple lesions; inflammatory changes on MRI; reversal of the inflammatory changes and central bony ankylosis at follow-up; and a good response to anti-inflammatory drugs. Traumatic lesions were associated with prolonged disease duration; a high mSASSS due to complete bony ankylosis between vertebral bodies; a previous history of trauma; single lesions; nonunion of fractures of the posterior column; acute kyphoscoliotic deformity with the lesion at the apex; instability, and the need for operative treatment due to that instability. It is essential to distinguish between inflammatory and traumatic Andersson lesions, as the former respond to medical treatment whereas the latter require surgery.
We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p <
0.001), and this was higher in bone segments having a less-remodelled site. This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip.
We reviewed the results of 84 total hip replacements performed with a short metaphyseal-fitting anatomical cementless femoral component in 84 unselected consecutive patients with a mean age of 78.9 years (70 to 88). The mean follow-up was 4.6 years (4 to 5). The mean pre-operative Harris hip score was 26 points (0 to 56), which improved to 89 (61 to 100) at the final follow-up. No patient had thigh pain. The mean pre-operative Western Ontario and McMaster Universities osteoarthritis index score was 61 points (48 to 75), which improved to 21 (6 to 46). The mean University of California, Los Angeles activity score was 5.5 points (3 to 7) at the final follow-up. Osseointegration was seen in all femoral and acetabular components. All hips had grade 1 stress shielding of the proximal femur. No acetabular or femoral osteolysis was identified. These results demonstrate that a short metaphyseal-fitting femoral component achieves optimal fixation without diaphyseal anchorage in elderly patients.
There have been comparatively few studies of the incidence of osteolysis and the survival of hybrid and cementless total hip replacements (THRs) in patients younger than 50 years of age. We prospectively reviewed 78 patients (109 hips) with a hybrid THR having a mean age of 43.4 years (21 to 50) and 79 patients (110 hips) with a cementless THR with a mean age of 46.8 years (21 to 49). The patients were evaluated clinically using the Harris hip score, the Western Ontario and McMaster Universities (WOMAC) osteoarthritis score and the University of California, Los Angeles (UCLA) activity score. Radiographs and CT scans were assessed for loosening and osteolysis. The mean follow-up was for 18.4 years (16 to 19) in both groups. The mean post-operative Harris hip scores (91 points Although the long-term fixation of the acetabular metallic shell and the cemented and cementless femoral components was outstanding, wear and peri-acetabular osteolysis constitute the major challenges of THR in young patients.
Our aim was to determine the success rate of repeated debridement and two-stage cementless revision arthroplasty according to the type of infected total hip replacement (THR). We enrolled 294 patients (294 hips) with an infected THR in the study. There were 222 men and 72 women with a mean age of 55.1 years (24.0 to 78.0). The rate of control of infection after the initial treatment and after repeated debridement and two-stage revisions was determined. The clinical (Harris hip score) and radiological results were evaluated. The mean follow-up was 10.4 years (5.0 to 14.0). The eventual rate of control of infection was 100.0% for early superficial post-operative infection, 98.4% for early deep post-operative infection, 98.5% for late chronic infection and 91.0% for acute haematogenous infection. Overall, 288 patients (98%) maintained a functioning THR at the latest follow-up. All the allografts appeared to be united and there were no failures. These techniques effectively controlled infection and maintained a functional THR with firm fixation in most patients. Repeated debridement and two-stage or repeated two-stage revisions further improved the rate of control of infection after the initial treatment and increased the likelihood of maintaining a functional THR.
We undertook a study in which 138 female patients with a mean age of 71.2 years (51 to 82) received a standard NexGen CR-flex prosthesis in one knee and a gender-specific NexGen CR-flex prosthesis in the other. The mean follow-up period was 3.25 years (3.1 to 3.5). The aspect ratios of the standard and gender-specific prostheses were compared with that of the distal femur. The mean post-operative Knee Society knee scores were 94 (70 to 100) and 93 (70 to 100) points and the function scores were 83 (60 to 100) and 84 (60 to 100) points for the standard implants and the gender-specific designs, respectively. The mean post-operative Western Ontario and McMaster Universities score was 26.4 points (0 to 76). Patient satisfaction, the radiological results and the complication rates were similar in the two groups. In those with a standard prosthesis, the femoral component was closely matched in 80 knees (58.0%), overhung in 14 (10.1%) and undercovered the bone in 44 (31.9%). In those with a gender-specific prosthesis, it was closely matched in 15 knees (10.9%) and undercovered the bone in 123 (89.1%). Since we found no significant differences between the two groups with regard to the clinical and radiological results, patient satisfaction or complication rate, the goal of the design of the gender-specific CR-flex prosthesis to improve the outcome was not achieved in our patients.
Hyaluronic acid (Hyalunan, HA), β-1,4-linked D-glucuronic acid and β-1,3 N-acetyl-D-glucosamine polysaccharide, is a nonsulfated glycosaminoglycan(GAG) conserved in the extracellular matrix (ECM). Due to its biocompatibility, biodegradable properties, HA is widely applied for tissue engineering. However, HA also has defects for tissue engineering such as mechanical properties, difficulty of handling. Thus, it is various modified by chemical reaction to produce HA derivative. HA plays an important role in tissue morphogenesis, proliferation and cell differentiation. Ascorbic acid (AA) has an effect on collagen synthesis and bone mineralization. Ascorbate levels also have a significant effect on osteoblast proliferation and alkaline phosphatase (ALP) expression. However AA is weak to heat and light, thus it is easily degradable. Consequently, we conjugated HA with AA in order to make it more stable and effective. In this study, we prepared HA-AA conjugate and evaluated activity of products in pre-osteoblast. To produce more effective conjugation, we synthesised HA derivative, HA-N-hydroxysuccinimide, an activated ester of the glucuronic acid moiety. This HA-active ester intermediate is a precursor for drug-polymer conjugates. The degree of substitution was calculated by NMR analysis. The modified HA was dialysed and lyophilised. The yield of conjugation is calculated by Gel Permeation Chromatography (GPC). After the process, HA was conjugated with AA once again as previously mentioned. In this study, the resultant HA-AA conjugate was tested on MC3T3-E1, murine pre-osteoblast cells. We examined cellular viability (cytotoxicity), proliferation and gene expression. The expression of Type 1 collagen was examined by RT-PCR and western blot. Osteocalcin (OCN), osteopontin (OPN) and bone sialoprotein (BSP), bone proliferation and differentiation marker were detected by RT-PCR. Alkaline phosphatase assay was also performed. For confirmation on bone mineralization, alizarin red staining and von Kossa staining was performed. In conclusion, the in vitro data demonstrate that HA-AA conjugate has an important role in bone formation, as it can increase proliferation and osteogenic differentiation of MC3T3-E1 cells. These observations further support the use of in vivo system for tissue engineering applications.
We have analyzed the long-term clinical and radiological results of 169 total knee replacements(TKRs) for rheumatoid arthritis over 10 years. The average follow up period was 12.8(10–17.6) years. The flexion contracture was improved from average 25.0 to 2.9 degrees. But the angle of great flexion had decreased from average 128.0 to 114.7 degrees. At the final follow up, the American Knee Society knee score was 87.5 and function score 76.5 in average. The revision arthroplasty was performed in 20 cases, but only 4 cases were done before 10 years after the primary TKRs. The survival rate of the implant was 97.9% at 10 years and 85.3% at 14 years in Kaplan-Meier survivorship analysis. But just after 10 years, problems such as osteolysis and periprosthetic fractures started to occur increasingly. 10-year follow up results is just the 10-year results only, not the long-term or final results of TKRs for rheumatoid arthritis.
The purpose of this study was to evaluate the effect of decreasing tibial slope on extention gap during posterior stabilized total knee arthroplasty. 110 posterior stabilized total knee arthroplasties were studied for 2 groups;
having flexion contractures(n=35), having no flexion contracture(n=75). In each group, we measured the decrease of tibial slope and frequency of additional distal femoral resecions that were done due to insufficient extension gap in comparison with flexion gap during posterior stabilized total knee arthroplasty. We also compared frequencies of additional distal femoral resections between 2 parts having more and less slope decrease in each groups. In each group, tibial slope decrease were 8.7 degrees, 7.4 degrees(p=0.145) and frequencies of additional resection were 51.4%, 24%(p=0.005) in average. In 2 parts having more and less slope decrease in each group, frequencies of additional resection were 44.4% vs 58.8%(p=0.505), 13.2% vs 35.1%(p=0.032). Results suggested that more decrease of tibial slope reduced frequency of additional distal femoral resection during posterior stabilized total knee arthroplasty in group having no flexion contracture. Decreasing tibial slope can be considered as a factor influencing on extension gap during posterior stabilized total knee arthroplasty. The estimation of predictable tibia slope decrease through preoperative radiologic findings can be beneficial in performing succeful posterior stabilized total knee arthroplasty.
Uncontained peripheral bone defect in posteromedial tibial plateau is not an infrequent problem even in primary total knee arthroplasty, especially in Korean patients some of those have large angular deformities preoperatively. We reviewed the clinical and radiological results of primary total knee replacements of 33 osteoarthritic knees in 28 patients with the use of metal block augmentation for uncontained peripheral tibial bone defects more than 5 millimeters in depth and more than a quarter of medial tibial plateau in width. Those defects were encountered in 75 knees (9.6%) during 779 primary total knee arthroplasties performed by single surgeon between January 2002 and December 2004 at our institution. Modular metal block augmentation was reserved for 42 knees, while the other knees were managed with bone-grafting or cement-filling techniques. Clinical and radiological follow-up more than 12 months were available from 33(78.6%) of 42 knees. At a mean of 32.2 months (range:12~75 months), 31 knees (93.9%) except two cases of failure were evaluated as good or excellent. The average pre-operative American Knee Society Knee and Function scores were 32.5 and 38.6 respectively, which increased to 82.9 and 79.8 respectively at the latest follow-up. There were no radiolucent lines (RLLs) beneath the metallic block or tibial tray, which were progressive or more than 2 millimeters on radiographs, in those knees. Revisions were required for one delayed infection and another aseptic loosening of tibial component. Non-progressive RLLs less than 2 millimeters at the cement-bone interface beneath the metallic block were noted in 10 (32.3%) of 31 knees. The RLLs appeared in 5 (41.7%) of 12 knees with metallic block augmentation alone and 5 (26.3%) of 19 knees which had been treated with the use of additional intramedullary stem augmentation, although this difference was not statistically significant. Since these radiolucent lines were not progressive or symptomatic at all, their clinical meanings or long-term consequences are not determined yet. All knees managed with the additional intramedullary stem augmentation revealed to have radiopaque lines adjacent to the stem on follow-up radiographs. The sclerotic halo around the tip of stem could be interpreted as evidence of the stem’s function in load sharing and might reflect secure fixation of tibial tray to bony interface. We concluded that the use of modular metal block augmentation devices for peripheral tibial defects measuring more than 5 millimeters could provide a simple, rapid and dependable technique that provides predictable results. The observation that all knees managed with additional intramedullary stem augmentation would have sclerotic halo adjacent to the stem on follow-up radiographs may reflect an intramedullary stem is an important adjunct to bone defect management.
To know how to succeed and survive for his or her whole life after the primary TKA by studying the causes of aseptic failure of the cruciate retaining type primary TKA. One hundred and seventy nine cases of revision of the TKA were analyzed concerning the causes of failure. The longest follow-up period was 25 years. All cases of the immediate postoperative and pre-revision weight bearing x-rays were reviewed. The operative findings of the revision surgery were compared with the pre-revision x-rays and physical findings. The results of this study were:
The incidence of wear of the tibial polyethylene insert was predominant. The most severe disability before revision was instability and dislocation of the joint due to excessive eccentric wear of the posteromedial part of the tibial polyethylene insert. All cases showed full ROM after primary TKA. The causes of the failures could be classified as follows: Implant Design: Flat surfaced tibial polyethylene insert could be related with an eccentric wear and a resultant instability. Posterior pegs of the tibial base plate might be related with a stress fracture of the posteromedial part of tibial condyle, which ended up with an eventual fracture of the tibial base plate and dislocation of the tibial polyethylene insert. The metal backed patella could cause early wear of the patellar polyethylene insert. Bone Cutting: The most common cause of the failure related with the bone cutting was insufficient valgus of the femorotibial angle, which was related with a wear of the medial side of the tibial polyethylene insert. Less than 50 of valgus could be related with an early wear of the tibial polyethylene insert. Soft tissue balance: Most important factors were insufficient medial release and tight PCL, which caused early wear of the posteromedial portion of the tibial polyethylene especially in high flexion knees. Fixation: All cases of loosening occurred in cases of cementless TKA. The excessive body weight which is known to be one of the causes of early failure was not a significant factor in this series. All aseptic failures occurred in high flexion knees. The causes of failures could be classified into four, the implant design, the bone cutting and the soft tissue balance and fixation. Long time survival could be achieved if those factors are perfect.
The purpose of this study was to examine surface characteristics of 30 alumina and 24 zirconia ceramic femoral heads and to identify phase transformation in zirconia heads. We also studied penetration rate of alumina and zirconia heads into UHMWPE liner. The alumina heads had been implanted for a mean of 11.3 years (8.1 to 16.2) and zirconia heads for a mean of 9.8 years (7.5 to 15). The mean surface roughness values of explanted alumina heads (Ra 40.12 nm and Rpm 578.34 nm) were similar to those for the explanted zirconia heads (Ra 36.12 nm and Rpm 607.34 nm). The mean value of monoclinic phase of two control non-implanted zirconia heads was 1% (0.8–1.5) and 1.2% (0.9–1.3), respectively. The mean value of monoclinic phase of 24 explanted zirconia heads was 7.3% (1% to 26%). In the alumina head group, mean linear penetration rate of UHMWPE liner was 0.10 mm/yr (0.09 to 0.12) in hips with low Ra and Rpm values (13.22 nm and 85.91 nm, respectively). The mean linear penetration rate of UHMWPE liner was 0.13 mm/yr (0.17 to 0.23) in the hips with high Ra and Rpm values (198.72 nm and 1329 nm, respectively). This differences was significant (P=0.041) In the zirconia head group, the mean linear penetration rate of UHMWPE liner was 0.09 mm/yr (0.07 to 0.14) in hips with low Ra and Rpm values (12.78 nm and 92.99 nm, respectively). The mean linear penetration rate of UHMWPE liner was 0.12 mm/yr (0.08 to 0.22) in hips with high Ra and Rpm values (199.21 nm and 1381 nm, respectively). This difference was significant (P=0.039). The explanted zirconia heads which had a minimal phase transformation had similar surface roughness and a similar penetration rate of UHMWPE liner as the explanted alumina head.
To investigate the amount and the factors of changes of the thickness of tibial polyethylene insert in revisional TKA compared to original thickness of primary TKA. We analyzed one hundred and twenty cases of wear, loosening and instability were included in this study. Infection cases were excluded. The period between the primary TKA and revision TKA was 88.5 months in average (range 1 to 17 year 3 months). The amount of increase of the tibial polyethylene thickness according to the main cause of failure and the wear site was analyzed. The results of this study were: 1: The increased thickness was 6.7 mm in average. 2: The amount of increase in case of wear of anterior portion only was 2.3 mm, which was below the average. 3: The loosening cases showed 8.2 mm increase in average which was significantly greater than the average. 4: The cases of greater wear of medial side than lateral side showed 8.5 mm increase of the thickness which was significantly greater than the average. 5: The cases of only medial side wear showed 5.5 mm increase of the thickness, which was below the average. 6: The cases of the other causes such as patellar component wear, generalized wear, wear of posterior portion only, early wear less than 5 years after primary TKA because of flat polyethylene surface showed comparable amount of wear to the average. The thickness of tibial polyethylene insert in revisional TKA compare to original thickness of primary TKA showed that it increased 6.7mm in average and was variable according to the cause of failure.
The purpose of this study is to analyze clinical and radiological results of total hip arthroplasty using the 3rd generation ceramic on ceramic articular surface. Between July 1999 and May 2005, 339 hips of 250 patients had primary cementless total hip arthroplasty with the 3rd generation ceramic on ceramic bearing implants. And 325 hips of 236 patients were followed up over 3 years. Male were 168 patients(237 hips) and female were 68 patients(88 hips). The mean age at the time of operation was 47.3(range, 25~76) years old and the mean follow up period was 62.4(range, 36~107.6) months. The preoperative diagnoses were osteonecrosis of the femoral head (ONFH) in 250 hips, secondary osteoarthritis in 55 hips(dysplasia in 35, infection sequalae in 12, LCP in 2, CDH in 2), hemophilic arthropathy in 9 hips, ankylosing spondylitis in 7 hips etc. We used Bicontact system(Aesculap, Germany) in 65 hips, Secur-FitTM(Stryker Howmedica Osteonics, USA) in 206 hips, Trilogy ABTM (Zimmer, USA) in 54 hips. Clinically, Harris Hip Score, thigh pain, squeaking and other complications were evaluated. Radiologically, the serial radiographs were analyzed. Clinically, the Harris hip score was improved from preoperative 66.0(19~91) to 96.2(58~100) at the last follow-up. Radiologically, there was no loosening of implants and visible wear and osteolysis. Heterotopic ossifications were noted in 5 cases. In complications, there was dislocation in one case, periprosthetic fracture in 2 cases and thigh pain in 9 cases. Intermittent squeaking sound has occurred in 8 cases(2.5%). Among these, one case of loud squeaking which happened after fall down had revision surgery. There was no infection and fracture of ceramic implant. Our midterm results of THA with the 3rd generation ceramic bearing system were very satisfactory and demonstrated that the 3rd generation ceramic bearings remain as an excellent bearing choice because of their superior wear characteristics. However, the results of this study suggests that the squeaking would be one of strong potential risk factors for failure of ceramic on ceramic total hip arthroplasty and we must be very cautious to prevent squeaking.
Architectural changes in occurring in the proximal femur (resorption) after total hip arthroplasty (due to stress shielding) continues to be a problem. In an attempt to reduce these bony changes the concept of short and femoral neck sparing stem designs have been advocated. The purpose of this study was to evaluate the early clinical and radiological results, especially stem fixation and bone remodeling of proximal femur after total hip arthroplasty. A total of forty-five patients (fifty-four hips) were included in the study. There were twenty men and twenty-five women. The mean age at the time of operation was 53.9 years (range, twenty-six to seventy-five years). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients one week after operation and at the final follow-up examination. The mean follow-up was 1.3 years (range, one to two years). The mean preoperative Harris hip score was 45 points (range, 15 to 48 points), which improved to a mean of 96 points (range, 85 to 100 points) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. One hip (2%) required open reduction and fixation with a cable for calcar femorale fracture. Bone mineral densitometry revealed a minimal bone remodeling in the acetbulum and proximal femur. The geometry of this ultra-short anatomic neck sparing cementless femoral stem has proved to provide effective initial stability even without the diaphyseal portion of the stem. We believe that femoral neck preservation and lateral flare of the stem provide an axial and torsional stability and more natural loading of the proximal femur.
Much attention has recently been paid to bioabsorbable polymeric materials, such as poly(L-lactic acid) (PLLA), in the field of orthopedics and oral surgery. For example, PLLA has extensively been used as resorbable bone fixation devices. Recently, hydroxyapatite (HA) micro-particles filled PLLA has also been developed to improve the bioactivity, elastic modulus and absorption rate of biomedical PLLA devices. Porous structures of PLLA and HA/PLLA composites have also been developed to improve osseous conduction so that these biomaterials can be used as scaffolds in tissue engineering for rejenerative medicine. Such porous materials may also be utilized as artificial bones in orthopedics. Thus, demand for porous PLLA and HA/PLLA is rapidly increasing, however, the relationships between their mechanical behavior and properties and their microstructure have not been well understood yet. In the present study, porous structures of PLLA and HA/PLLA with continuous pores are developed by using a solid-liquid phase separation technique and a subsequent solvent sublimation process. Size of pores and porosity are varied by changing the concentration of the solutions. Compression and shear tests are performed to evaluate the elastic moduli and strengths. Field emission scanning electron microscopy (FE-SEM) of the deformation behavior at the critical transformation points from linear elastic to nonlinear deformation is conducted to characterize the mechanism of such microscopic deformation at the critical point. Microscopic deformation and failure behavior of such porous structures are then characterized on the basis of FE-SEM results, and then correlated with the macroscopic mechanical properties. Structural modification is also tried to improve the mechanical properties to extend the applicability of the porous biomaterials.
To analyze the mechanism of failure and basic cause in cases of early failure which were required revision within 5 years index TKA. Between 1991 and 2006, 167 revisions TKA of aseptic failure were performed. Revision diagnosis or reason for failure were categorized as wear of tibial polyethylene insert, failure of tibial base plate, early imbalance between medial and lateral soft tension, tight or loose PCL and posterior capsule. The percentages of each failure category were calculated as a percentage of the overall number of revision TKA and a percentage of the early failures. A descriptive statistics were calculated for the time in situ for each failure category. Early failure within 5 years following index TKA occurred in 33 out of 167 TKA(20.0%). Average time in situ was 38.53 months(3.21 years). Wear of the tibial polyethylene insert occurred in 12 out of 33 cases(36.4%). All cases showed tight PCL. Loosening was the second leading cause occurring in 9 cases(27.2%). Pure instability with tight MCL occurred in 3 knees. Catastrophic early wear within one year after index surgery occurred in 18 knees. The cause of failure were flat surfaced poly in 11, fracture of metal tray 2, dislocation of the thick poly insert 1 and early poly wear due to unknown cause 4. There were multiple factors of the early failure, which could be divided into design failure and surgical skill failure. However, they worked together in most of the cases.
Many reports show good results following procedures, such as intervertebral body fusion using cage or total disc replacement, that restore adequate disc height. However, there have been no references regarding the range of normal lumbar disc height in Korean adults which can be used as a standard for the implant size. The purpose of our study is to measure the lumbar disc height on radiographs in normal Korean. 132 subjects (age range 20 to 40 years) who had no previous history of low back pain and no significant finding on physical examination were enrolled. Plain lateral lumbar spine radiograph in supine position were taken. Intervertebral disc heights were measured at anterior, middle and posterior portion of each lumbar disc. The average magnification rate was 115%, and the disc heights were corrected by the magnification rate in each segment. Lumbar disc height showed cranio-caudal pattern in both male and female groups. L4–5 disc heights were highest at anterior, middle and posterior portion in male. L4–5 disc heights were highest at middle and posterior portion in female. L5-S1 disc height was highest at anterior portion in female, but there was no statistically significant difference between L4–5 and L5-S1 disc height at anterior portion. There was no significant difference in disc height between male and female except anterior portion of L1–2 and L2–3 disc. Statistically significant decrease in disc height was not presented in overweight person at all measured site in male and female except posterior portion of L1–2 disc in male. This research is meaningful in that it is an attempt to provide a reference value of lumbar disc height in Korean adults, and the measured values may also be useful in manufacturing Korean modeled artificial lumbar disc prosthesis or surgical instruments for lumbar interbody fusion.
Recently with the introduction of operations using various instrument of total ankle arthroplasty, we are showing quite satisfactory short term results on the treatment of resolved pain of ankle joint. However, there have been reports of high probability of complication from total ankle arthroplasty to other arthroplasty applied to other joints. Therefore in order to make the results of ankle arthroplasty superior, it is necessary to reduce these complications. We try to analyze complications that occur often and come up with the best results. There were 45 cases of 42 patients of HINTEGRA® (Newdeal SA, Lyon, France) model from November 2004 to August 2006. Follow up averaged 33.5 months, the average age of patients was 61.1 years, with 14 males and 28 females. We evaluated the complications and analyzed the causes of failures. There was a total 15 cases of complications; 5 cases of medical impingement syndrome, 3 cases of varus malposition, 2 cases of delayed healing of wound, 1 case of peroneal nerve problem, medial malleolar fracture, postoperative deep infection and gouty arthritis pain and Achilles tendinitis. Our conclusion is that total ankle arthroplasty had more complication rate than other joint arthroplasty, so we need a more meticulous preoperative and perioperative care.
Beta–tricalciumphosphate(β-TCP)coatinglayerisknown to be resorbed much faster than hydroxyapatite(HA), however, there has been few reports explaining the exact mechanism until now. Therefore, we investigated whether the resorption mechanisms of these two compounds are same, if not, what is the difference. Eighty titanium discs with 12mm in diameter and 2mm in thickness were coated with HA(n=40) or β-TCP(n=40) by dip and spin coating method. In each group, the specimens were divided into 2 subgroups respectively; Dissolution (D, n=20) group and Osteoclast culture (C, n=20) group. The coated discs in D group were immersed in the cell culture media for 5 days, whereas, in C group, osteoclast-like cells (5×103 cells/500μ), which were isolated form human giant cell tumor, were seeded on the specimens and cultured for 5 days. Cultured cells were defined as osteoclast by the determination of osteoclast marker (tartrate-resistant acid phosphatase, TRAP). After immersion or osteoclast culture, the dissolution characteristics of coating surface were observed using light microscope (LM) and scanning electron microscope (SEM). And the area fraction of resorption lacunae formed by osteoclast was analyzed by image analysis to evaluate the activity of osteoclastic degradation. After 5 days of dissolution, there were much more cracks and denuded areas in β-TCP coating compared to HA coating. In C group, the osteoclasts covering the coating layer were identified on LM and SEM images. Mean area fraction of resorption lacunae in HA-C group was 11.62%, which was significantly higher than that of 0.73% of β-TCP-C group (p=0.001). We conclude that the resorption mechanism of HA and β-TCP coating layers was different each other in vitro study. The coated β-TCP was degraded mainly by dissolution and also tended to be separated from implant, on the other hand, the HA coating layer was resorbed by osteoclastic activity
Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.
We investigated whether simultaneous bilateral sequential total hip replacement (THR) would increase the rate of mortality and complications compared with unilateral THR in both low- and high-risk groups of patients. We enrolled 978 patients with bilateral and 1666 with unilateral THR in the study. There were no significant pre-operative differences between the groups in regard to age, gender, body mass index, diagnosis, comorbidity as assessed by the grading of the American Society of Anesthesiologists (ASA), the type of prosthesis and the duration of follow-up. The mean follow-up was for 10.5 years (5 to 13) in the bilateral THR group and 9.8 years (5 to 14) in the unilateral group. The peri-operative mortality rate of patients who had simultaneous bilateral THR (0.31%, three of 978 patients) was similar to that of patients with unilateral THR (0.18%, three of 1666 patients). The peri-operative mortality rate of patients in the bilateral group was similar in high risk and low risk patients (0.70%, two of 285 patients vs 0.14%, one of 693 patients) and this was also true in the unilateral THR group (0.40%, two of 500 patients vs 0.09%, one of 1166 patients). Patients with bilateral THR required more blood transfusions and a longer hospital stay than those in the unilateral THR group. There was no significant difference (p = 0.32) in the overall number of complications between the groups. This was also true for the low-risk (p = 0.81) vs high-risk (p = 0.631) patients. Our findings confirm that simultaneous sequential bilateral THR is a safe option for patients who are considered to be either high or low risk according to the ASA classification.
We wished to determine whether simultaneous bilateral sequential total knee replacement (TKR) carried increased rates of mortality and complications compared with unilateral TKR in low- and high-risk patients. Our study included 2385 patients who had undergone bilateral sequential TKR under one anaesthetic and 719 who had unilateral TKR. There were no significant pre-operative differences between the groups in terms of age, gender, height, weight, body mass index, diagnosis, comorbidity and duration of follow-up, which was a mean of 10.2 years (5 to 14) in the bilateral and 10.4 years (5 to 14) in the unilateral group. The peri-operative mortality rate (eight patients, 0.3%) of patients who had bilateral sequential TKR was similar to that (five patients, 0.7%) of those undergoing unilateral TKR. In bilateral cases the peri-operative mortality rate (three patients, 0.4%) of patients at high risk was similar to that (five patients, 0.3%) of patients at low risk as it was also in unilateral cases (two patients, 1.0% vs three patients, 0.6%). There was no significant difference (p = 0.735) in either the overall number of major complications between bilateral and unilateral cases or between low- (p = 0.57) and high-risk (p = 0.61) patients. Also, the overall number of minor complications was not significantly different between the bilateral and unilateral group (p = 0.143). Simultaneous bilateral sequential TKR can be offered to patients at low and high risk and has an expected rate of complications similar to that of unilateral TKR.
The purpose of this study was to determine objectively the outcome of total knee replacement in patients with ankylosed knees. There were 82 patients (99 knees) with ankylosed knees who underwent total knee replacement with a condylar constrained or a posterior stabilised prosthesis. Their mean age was 41.9 years (23 to 60) and the mean follow-up was for 8.9 years (6.6 to 14). Pre- and post-operative data included the Hospital for Special Surgery (HSS), the Knee Society (KS) and the Western Ontario and McMaster University Osteoarthritis index (WOMAC) scores. The mean HSS, KS and WOMAC scores improved from 60, 53, and 79 pre-operatively to 81, 85, and 37 at follow-up. These improvements were statistically significant (p = 0.018, 0.001 and 0.014 respectively). The mean physical, social and emotional WOMAC scores also improved significantly (p = 0.032, p = 0.023 and p <
0.001 respectively). The mean satisfaction score was 8.5 ( Total knee replacement gives good mid-term results in patients with ankylosed knees.
It has been suggested that the wear of ultra-high molecular weight polyethylene (UHMWPE) in total hip replacement is substantially reduced when the femoral head is ceramic rather than metal. However, studies of alumina and zirconia ceramic femoral heads on the penetration of an UHMWPE liner The purpose of this study was to examine the surface characteristics of 30 alumina and 24 zirconia ceramic femoral heads and to identify any phase transformation in the zirconia heads. We also studied the penetration rate of alumina and zirconia heads into contemporary UHMWPE liners. The alumina heads had been implanted for a mean of 11.3 years (8.1 to 16.2) and zirconia heads for a mean of 9.8 years (7.5 to 15). The mean surface roughness values of the explanted alumina heads (Ra 40.12 nm and Rpm 578.34 nm) were similar to those for the explanted zirconia heads (Ra 36.21 nm and Rpm 607.34 nm). The mean value of the monoclinic phase of two control zirconia heads was 1% (0.8% to 1.5%) and 1.2% (0.9% to 1.3%), respectively. The mean value of the monoclinic phase of 24 explanted zirconia heads was 7.3% (1% to 26%). In the alumina group, the mean linear penetration rate of the UMWPE liner was 0.10 mm/yr (0.09 to 0.12) in hips with low Ra and Rpm values (13.22 nm and 85.91 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.13 mm/yr (0.07 to 0.23) in hips with high Ra and Rpm values (198.72 nm and 1329 nm, respectively). This difference was significant (p = 0.041). In the zirconia head group, the mean linear penetration rate of the UHMWPE liner was 0.09 mm/yr (0.07 to 0.14) in hips with low Ra and Rpm values (12.78 nm and 92.99 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.12 mm/yr (0.08 to 0.22) in hips with high Ra and Rpm values (199.21 nm and 1381 nm, respectively). This difference was significant (p = 0.039). The explanted zirconia heads which had a minimal phase transformation had similar surface roughness and a similar penetration rate of UHMWPE liner as the explanted alumina head.
We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter. The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection. The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student’s We found no evidence of the superiority of one design over the other at long-term follow-up.
We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p >
0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing.
We performed a prospective, randomised study to compare the results and rates of complications of primary total knee replacement performed using a quadriceps-sparing technique or a standard arthrotomy in 120 patients who had bilateral total knee replacements carried out under the same anaesthetic. The clinical results, pain scales, surgical and hospital data, post-operative complications and radiological results were compared. No significant differences were found between the two groups with respect to the blood loss, knee score, function score, pain scale, range of movement or radiological findings. In contrast, the operating time (p = 0.0001) and the tourniquet time (p <
0.0001) were significantly longer in the quadriceps-sparing group, as was the rate of complications (p = 0.0468). We therefore recommend the use of a standard arthrotomy with the shortest possible skin incision for total knee replacement.
Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3). The operating and tourniquet times were significantly longer in the navigation group (p <
0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920). In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement.