Advertisement for orthosearch.org.uk
Results 1 - 20 of 9897
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 50 - 50
22 Nov 2024
Hvistendahl MA Bue M Hanberg P Tøstesen S Vittrup S Stilling M Høy K
Full Access

Aim. Antibiotic prophylaxis is central in preventing postoperative spine infections, yet knowledge of clinical spine tissue antibiotic concentrations remains limited. Pooled postoperative spine infection rates are constant (approximately 3%), resulting in severe patient morbidity, mortality, and prolonged hospitalization. Current antibiotic dosing regimens often involve fixed doses based on empirical knowledge, surrogate measures (plasma samples), non-clinical evidence (experimental models), and inferior methodology (tissue specimens). Therefore, personalized antibiotic dosing may be the future of antibiotic prophylaxis to prevent postoperative infections, especially implant infections. The aim was to continuously evaluate intra- and postoperative cefuroxime target spine tissue concentrations in long-lasting spine surgery after personalized dosing by repeated weight-dosed intravenous administrations. Method. Twenty patients (15 female, 5 male) scheduled for long-lasting spine deformity surgery with hypotensive anaesthesia were included; median age (range): 17.5 years (12-74), mean BMI (range): 22.2 (16.2-37.7), and mean surgery time (range): 4h 49min (3h 57min-6h 9min). Weight-dosed cefuroxime (20 mg/kg) was administered intravenously to all patients on average 25 min before incision and repeated after 4 hours. Microdialysis catheters were placed for sampling of cefuroxime concentrations in vertebral bone (only intraoperative sampling), paravertebral muscle, and subcutaneous tissue as soon as possible after surgery start. Upon wound closure, two additional catheters were placed in the profound and superficial part of the wound. Microdialysis and plasma samples were obtained continuously intra- and postoperative for up to 12 hours. The primary endpoint was (based on cefuroxime time-dependent efficacy) the time with cefuroxime concentrations above the clinical breakpoint minimal inhibitory concentration for Staphylococcus aureus of 4 µg/mL in percentage (%fT>MIC4) of. (a). patients’ individual surgery time,. (b). first dosing interval (0-4 hours),. (c). second dosing interval (4-12 hours). Results. Mean cefuroxime %fT>MIC4 (range) of:. (a). patients’ individual surgery time was 100% (100-100%) in all investigated tissues. (b). the first dosing interval was 93% (93-93%) in vertebral bone, paravertebral muscle, subcutaneous tissue, and 99% (99-100%) in plasma. (c). the second dosing interval was 87% (52-100%) in paravertebral muscle, 89% (52-100%) in subcutaneous tissue, 91% (71-100%) in the profound wound, 94% (72-100%) in the superficial wound, and 71% (42-100%) in plasma. Conclusions. Personalized cefuroxime dosing by repeated weight-dosed (20 mg/kg) intravenous administrations provided homogenous and therapeutic spine tissue exposure across all investigated tissues and plasma in long-lasting spine surgery with hypotensive anaesthesia (up to 11 hours). Thus, personalized cefuroxime dosing may decrease the risk of postoperative spine infection, especially in cases with implant insertion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 32 - 32
22 Nov 2024
Granata V Strina D Possetti V Leone R Valentino S Chiappetta K Bottazzi B Mantovani A Loppini M Asselta R Sobacchi C Inforzato A
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the most serious and frequent complications in prosthetic surgery. Despite significant improvements in the criteria for diagnosis of PJI, the diagnostic workflow remains complex and, sometimes, inconclusive. Host immune factors hold great potential as diagnostic biomarkers in bone and joint infections. We have recently reported that the synovial concentration of the humoral pattern recognition molecule long pentraxin 3 (PTX3) is a sensitive and specific marker of PJI in total hip and knee arthroplasty patients (THA and TKA) undergoing revision surgery [1]. However, the contribution to risk and diagnosis of PJI of the genetic variation in PTX3 and inflammatory genes that are known to affect its expression (IL-1b, IL-6, IL-10, and IL-17A) has not been addressed. Therefore, we assessed these relationships in a cohort of THA and TKA patients who underwent prosthesis revision by focusing on a panel of single nucleotide polymorphisms (SNPs) in the PTX3, IL-1β, IL-6, IL-10 and IL-17A genes. Method. A case-control retrospective study was conducted on an historic cohort of patients that received THA or TKA revision and were diagnosed with PJI (cases) or aseptic complications (controls) [1]. Samples of saliva were collected from 93 subjects and used for extraction of genomic DNA to perform genotyping of the PTX3, IL-1β, IL-6, IL-10 and IL-17A polymorphisms. Moreover, whenever available, samples of synovial fluid and plasma [1] were used to measure the concentration of the IL-1β, IL-10, and IL-6 proteins by immunoassay. Uni-and multivariate analyses were performed to evaluate the relationships between genetic, biochemical, and clinical variables. Results. The rs3024491 (IL-10) and rs2853550 (IL-1b) SNPs were found to be strongly associated with the risk of PJI. The synovial levels of PTX3, IL-1β, IL-10, and IL-6 were higher in cases than in controls, and a clear correlation emerged between the synovial concentration of PTX3 and IL-1b in cases only. Also, we identified a causal relationship between rs2853550, synovial concentration of IL-1b and that of PTX3 (that is induced by IL-1b). Conclusions. Our findings suggest that SNPs in the IL-10 and IL-1b genes could be used for early identification of THA and TKA patients with high risk of PJI. It is therefore conceivable that integrating genetic data into current diagnostic criteria would improve diagnosis of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 29 - 29
22 Nov 2024
Trebše N Blas M Kanalec T Angelini K Filipič T Levašic V Trebse R
Full Access

Aim. There is limited data on the frequency and impact of untoward events such as glove perforation, contamination of the surgical field (drape perforation, laceration, detachment), the unsterile object in the surgical field (hair, sweat droplet…), defecation, elevated air temperature…that may happen in the operating theatre. These events should influence the surgical site infection rate but it is not clear to what extent. We wanted to calculate the frequency and measure the impact of these events on the infection and general revision rate. Method. In our institution, scrub nurses prospectively and diligently record untoward events in the theatres. We have an institutional implant registry with close to 100% data completion since 2001, and surgeons register complications before discharge. We analysed the respective databases and compared the revision and infection rate in the group with untoward events with the outcome of all arthroplasty patients within the same period. Two-tailed Z statistical test was used for analysis. Results. Between 1.1.2012 and 31.12.2018 we operated 13574 prosthetic joints: 6232 primary THR (total hip replacement) and 5466 primary KR (total and partial knee replacement) and 1245 and 631 revisions respectively. During this period, we recorded 372 events (2.74%) including 20 (0.15 %) defecations, 40 (0.29 %) unsterile object in the surgical field, 73 (0.54%) field sterility violations, 45 (0.33 %) glove perforations, 45 (0.33 %) occasions with elevated air temperature, 106 (0.78%) with guests in the OR, 11 (0.08%) with wound near the surgical field, and 32 (0.24%) with other events. We followed the patients till 1.1.2022, in this time we recorded 27 (7.26%) reoperations in the cohort with untoward events. There were 9 (2.42%) infections and 18 (4.84%) aseptic revisions in the group with unwanted events. The infection rate for all TJR (total joint replacement) from the period 2012-2018, followed till 1.1.2022 was 2.23%, the revision rate for any reason was 4.37%. For all THR (primary and revision) the infection rate was 0.84%, the overall revision rate was 3.18% and for the KR (primary and revision) 1.71% and 5,82% respectively. The difference is significant at p>0.05 for infection rate. Conclusions. The potentially serious sterility disruptive events in the operative rooms did result in an increased infection rate but not an increase in revision rate. There is no data about the rate and the impact of these events besides for perforated surgical gloves with higher reported incidences than in our study influencing infection rate if perioperative antibiotic prophylaxis was not used. Ours is the first study reporting the impact of these unwanted events in the operating theatre. Key words. orthopaedic surgery, unwanted events, revision rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 53 - 53
22 Nov 2024
Wallander K Beijer G Eliasson E Giske C Ponzer S Söderquist B Eriksen J
Full Access

Aim. Swedish guidelines on antibiotic prophylaxis in arthroplasty surgery recommend cloxacillin in fixed doses that pay little attention to the patient's renal function and weight. Nevertheless, there are no studies on whether the resulting free prophylactic cloxacillin in vivo concentrations are optimal. We aimed to evaluate whether the current recommended prophylactic dosage of cloxacillin is adequate. Method. We performed a prospective two-centre study, measuring the free (active) cloxacillin concentrations in plasma throughout surgery, in patients subject to primary hip and knee prosthetic joint replacements, aiming at 100 patients per centre. To account for plasma-bone exposure differences, concentrations were considered adequate if twice the epidemiological cut-off value for cloxacillin concerning wild type Staphylococcus aureus whereas two-three times were labelled threshold values. The two enrolling hospitals are acute care hospitals in central Sweden, also performing 600 - 1200 primary hip and knee joint arthroplasties annually. All patients scheduled for elective primary hip or knee replacements from January 2022 to April 2024 were eligible for participation. Exclusion criteria were allergy towards penicillins, cognitive disorders leading to inability to sign informed consent, and an absence of interpreter in case of a patient not speaking Swedish or English. Results. We present results from the first 49 patients included. Four patients had free cloxacillin concentrations below cut-off (8.2%). These four cases had prolonged surgeries of 77-100 minutes. An additional 5/49 (10.2%) had threshold values. Conversely 5/49 (10.2%) cases had concentrations exceeding 15 times the needed. No cases with threshold or low cloxacillin concentrations were attributable to a lack of concerning timing and dosing of cloxacillin. All concentrations were above or equal to our cut-off at the start of surgery. Eighteen percent of patients were of normal of weight (BMI 18.5- 25). Of the rest 4% were morbidly obese (BMI >40), 41% obese (BMI 30-40) and 37% overweight (BMI 25-30). Twenty seven percent (43/159) had diabetes and 45% suffered cardiac disease. Conclusions. Some patients in our cohort had insufficient active cloxacillin levels at the end of prosthetic joint surgery. Previous studies indicate that insufficient prophylactic antibiotic concentrations might lead to an enhanced risk of prosthetic joint infections. Other patients were massively overdosed, leading to unnecessary ecological effects and potentially adverse reactions. As inadequate cloxacillin concentrations were not associated with a lack of compliance to current guidelines a change in practise might be needed. Our final results may help to determine how dosing should be adjusted


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 24 - 24
22 Nov 2024
Veerman K Telgt D Rijnen W Donders R Kullberg BJ Wertheim H Goosen J
Full Access

Aim. Periprosthetic joint infection (PJI) is a severe complication after total joint arthroplasty. To prevent PJI, strict infection prevention measures are followed in combination with surgical antibiotic prophylaxis (SAP). To date, scientific reports concerning the optimal duration of SAP in revision arthroplasty are scarce. The aim of this multicenter open-label, randomized controlled trial in the Netherlands, is to investigate the superiority of 5 days (extended) versus a single dose of cefazolin to prevent PJI within the first year after revision arthroplasty of the hip and knee. Method. Included patients with an assumed aseptic hip or knee revision procedure received a single dose of 2 or 3 gram cefazolin preoperatively. Patients were randomly assigned in a 1:1 ratio to receive extended prophylaxis of cefazolin during 5 days postoperatively versus no prophylaxis after wound closure. Patients were excluded if evidence of PJI at revision. The primary endpoint was the incidence of PJI within one year after revision arthroplasty. PJI was defined according to the 2018 Philadelphia consensus criteria. With a sample size of 746 patients, an alpha of 5% and a power of 80%, superiority of the extended regimen would be shown if the lower boundary of the 95% confidence interval (CI) of the absolute between-group difference of the percentage of PJI is below −4%. Results. In total 751 patients were included for analysis: 379 in the single dose cefazolin group and 372 in the extended group. Within one year, PJI occurred in 2.6% (10/379) in the single dose group and 2.4% (9/372) in the extended group (risk difference, −0.2 percentage points; 95% CI, −2.5 to 2.0%), thus superiority was not shown. Adverse drug events were seen in 20 cases with extended and 7 cases with a single dose prophylaxis. Conclusions. Extended prophylaxis is not significantly superior to a single dose of cefazolin to prevent PJI within the first year after revision arthroplasty of the hip or knee. This is the first randomized controlled trail in which the duration of SAP in the selected group of patients undergoing revision arthroplasty was studied. Extending SAP after closure of the wound could increase the selection or induction of antimicrobial resistance, has an increased risk for adverse drug events, and is therefore not in line with the primary goal of antimicrobial stewardship, comprising optimizing clinical outcomes and ensuring cost-effective therapy while minimizing unintended consequences of antimicrobial use


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 40 - 40
22 Nov 2024
Chao C Khilnani T Jo S Yang X Bostrom M Carli A
Full Access

Aim. Periprosthetic joint infection (PJI) is a complication of total joint arthroplasty that typically requires revision surgery for treatment. Systemic antibiotics are usually held prior to surgery to improve yield of intraoperative cultures. However, recent studies suggest that preoperative aspirations have a high concordance with intraoperative cultures, which may allow surgeons to initiate antibiotic treatment earlier. The purpose of the study was to investigate the effect of Pre-surgical systemic antibiotic therapy on the bacterial burden within the periprosthetic space and systemic immune reaction. Method. PJI was induced with MSSA (Xen36) S. aureus in the right knee of 16-week old, female, C57BL6 mice using a previously validated murine model. Mice were randomized to three groups (n=8, each): control; Vanc, receiving systemic vancomycin (110mg/kg, SQ, twice daily); or VancRif receiving vancomycin same as in Vanc group, plus rifampin (12mg/kg dose, IV, once daily). Following 2 weeks of treatment, mice were euthanized and periprosthetic bone, soft tissue and the implant were harvested. Bacterial burden, colony forming units (CFUs), was quantified in soft tissue, tibial bone, and on the implant. Specifically, tissues were homogenized and serially plated for CFUs, while the implant was sonicated and then plated for CFUs. The host immune response was analysed through weighing inguinal and iliac lymph nodes and through measuring serum amyloid A (SAA). Non-parametric pairwise group comparisons of the three outcome measures were performed using a Mann-Whitney U test. Results. VancRif, the combined treatment significantly reduced bacterial burden in the periprosthetic soft tissue, bone, and implant compared to control (p<0.001) and Vanc alone (p<0.001). While not significant, Vanc alone did reduce bacterial load as compared to control. The ipsilateral weight of the iliac lymph nodes was significantly reduced in Vanc and VancRif mice compared to controls (p<0.001), was well as in VancRif versus Vanc alone (p<0.001). Interestingly, SAA levels did not significantly differ among all groups. During tissue harvesting, minimal purulence was observed in antibiotic treatment groups, unlike controls. Conclusions. Treating active PJI with vancomycin alone decreases periprosthetic bacterial loads and reduces the local immunological response. This effect is significantly enhanced with the combined rifampin use. These findings could suggest that when culture positive PJI is diagnosed, pre-surgical treatment with antibiotics may decrease immunosuppression and soft tissue infiltration, leading to a better chance of infection cure with subsequent surgical debridement. Histological investigations and repeat experiments involving subsequent surgical treatment are underway. Acknowledgements. Funding comes from internal institutional grants


Bone & Joint Research
Vol. 13, Issue 11 | Pages 659 - 672
20 Nov 2024
Mo H Sun K Hou Y Ruan Z He Z Liu H Li L Wang Z Guo F

Aims

Osteoarthritis (OA) is a common degenerative disease. PA28γ is a member of the 11S proteasome activator and is involved in the regulation of several important cellular processes, including cell proliferation, apoptosis, and inflammation. This study aimed to explore the role of PA28γ in the occurrence and development of OA and its potential mechanism.

Methods

A total of 120 newborn male mice were employed for the isolation and culture of primary chondrocytes. OA-related indicators such as anabolism, catabolism, inflammation, and apoptosis were detected. Effects and related mechanisms of PA28γ in chondrocyte endoplasmic reticulum (ER) stress were studied using western blotting, real-time polymerase chain reaction (PCR), and immunofluorescence. The OA mouse model was established by destabilized medial meniscus (DMM) surgery, and adenovirus was injected into the knee cavity of 15 12-week-old male mice to reduce the expression of PA28γ. The degree of cartilage destruction was evaluated by haematoxylin and eosin (HE) staining, safranin O/fast green staining, toluidine blue staining, and immunohistochemistry.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1041 - 1048
19 Nov 2024
Delgado C Martínez-Rodríguez JM Candura D Valencia M Martínez-Catalán N Calvo E

Aims

The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents.

Methods

We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1037 - 1040
15 Nov 2024
Wu DY Lam EKF

Aims

The first metatarsal pronation deformity of hallux valgus feet is widely recognized. However, its assessment relies mostly on 3D standing CT scans. Two radiological signs, the first metatarsal round head (RH) and inferior tuberosity position (ITP), have been described, but are seldom used to aid in diagnosis. This study was undertaken to determine the reliability and validity of these two signs for a more convenient and affordable preoperative assessment and postoperative comparison.

Methods

A total of 200 feet were randomly selected from the radiograph archives of a foot and ankle clinic. An anteroposterior view of both feet was taken while standing on the same x-ray platform. The intermetatarsal angle (IMA), metatarsophalangeal angle (MPA), medial sesamoid position, RH, and ITP signs were assessed for statistical analysis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 32 - 32
14 Nov 2024
Mungalpara N Kim S Baker H Lee C Shakya A Chen K Athiviraham A Koh J Elhassan B Maassen NH Amirouche F
Full Access

Introduction. Supraspinatus and infraspinatus tears (Massive Rotator Cuff Tear- MRCT) cause compensatory activation of the teres minor (TM) and subscapularis (SubS) to maintain humeral head alignment. This study measures force changes in TM and SubS using a dynamic shoulder testing setup. We hypothesize that combining superior capsule reconstruction (SCR) and lower trapezius tendon (LTT) transfer will correct rotator cuff forces. Methods. Eight fresh-frozen human shoulder specimens from donors aged 55-75 (mean = 63.75 years), balanced for gender, averaging 219.5 lbs, were used. Rotator cuff and deltoid tendons were connected to force sensors through a pulley system, with the deltoid linked to a servohydraulic motor for dynamic force measurement. The system allowed unrestricted humeral abduction from 0 to 90 degrees. Results. Teres Minor (TM):. -. Control: 7.43 N (SD = 1.66). -. SS tear: 5.46 N (SD = 1.45). -. MRCT: 3.94 N (SD = 1.43). -. LTT post-MRCT: 5.85 N (SD = 1.13). -. SCR post-MRCT: 4.68 N (SD = 0.71). -. Combined LTT+SCR: 6.43 N (SD = 1.24). -. TM force reduction: 26.51% post-SS tear, 46.97% from intact to MRCT, 63.20% increase with LTT+SCR. Subscapularis (SubS):. -. Control: -0.73 N (SD = 0.43). -. SS tear: -0.46 N (SD = 0.36), 36.99% increase. -. MRCT: 0.96 N (SD = 0.47), 31.51% increase. -. LTT post-MRCT: -0.32 N (SD = 0.47), 66.67% reduction. -. SCR post-MRCT: -0.28 N (SD = 0.16), 70.83% reduction. -. Combined LTT+SCR: -0.66 N (SD = 0.32), 31.25% reduction. Non-parametric Friedman's ANOVA showed overall statistical significance for TM (P = 1.083×10. -6. ) and SubS (P = 4.77×10. -4. ). Conclusion. The cadaveric model assesses rotator cuff compensations, showing significant TM force reductions following rotator cuff tears and improvements with LTT and SCR, particularly when combined. SubS exhibited negative force during normal abduction but compensated during MRCT, returning to normal values post-LTT and SCR


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 53 - 53
14 Nov 2024
Fridberg M Rahbek O Husum H Bafor A Duch K Iobst C Kold S
Full Access

Introduction. Patients with external fixators are at risk of pin site infection. A more objective assessment of possible pin site infection is warranted, particularly for future home-based monitoring of pin sites. The aim was to determine if thermography can detect signs of inflammation around pin sites by 1) Establishing a maximum temperature cut-off value 2) Investigating the correlation between local temperature and visual signs of inflammation 3) Adjust for anatomical location and ambient room temperature. Method. This was a cross-sectional international multi-center study following STROBE guidelines. All patients with external ring-fixators scheduled for a visit in the out-patient clinic were eligible. Visual signs of inflammation were categorized using the Modified Gordon classification System (MGS, simplified sMGS). Thermographic imaging was done with an infrared camera (FLIR T540) and the maximum temperature within the ROI (MaxTp) was the primary outcome measure. Sample size and reliability were estimated. Cohen-Kappa, ROC-curve/AUC and Poisson regression were used for statistical analysis. Result. Data from 1970 pin sites were included. Inter-rater reliability of MGS was Kappa=0.79 and for MaxTp ICC=0.99 (95%CI: 0.99;0.99). Overall, a tendency of rising temperature with increasing sMGS was seen. The difference between sMGS=0 and sMGS>0 was significant. The performance of MaxTp as a screening tool to detect inflammation was reasonable with an AUC of 0.71 (95% CI: 0.65-0.76). The empirically optimal cut-off value was 34.1°C (Sensitivity=65%, Specificity=72%, Positive predictive value=23%, Negative Predictive value=94%). A 1°C increase in MaxTp increased the RR of visual signs of inflammation by a factor 1.5 (95% CI: 1.3; 1.7). Conclusion. We found a clinical positive association between the temperature at the pin site measured with thermography and visual signs of inflammation. The empirically optimal temperature cut-off value for inflammation screening was 34.1°C. Thermography may be a promising tool for a for a future point of care technology


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 103 - 103
14 Nov 2024
Dhaliwal J Harris S Logishetty K Brkljač M Cobb J
Full Access

Introduction. The current methods for measuring femoral torsion have limitations, including variability and inaccuracies. Existing 3D methods are not reliable for abnormal femoral anteversion measurement. A new 3D method is needed for accurate measurement and planning of proximal femoral osteotomies. Currently available software for viewing and modelling CT data lacks measurement capabilities. The MSK Hip planner aims to address these limitations by combining measurement, planning, and analysis functionalities into one tool. We aim to answer 5 key questions: Is there a difference between 2D measurement methods? Is there a difference between 3D measurement methods? Is there a difference between 2D and 3D measurement methods? Are any of the measurement methods affected by the presence of osteoarthritis or a CAM deformity?. Method. After segmentation was carried out on 42 femoral CT scans using Osirix, 3D bone models were landmarked in the MSK lab hip planning software. Murphy's, Reikeras’, McBryde, and the novel MSK lab method were used to measure femoral anteversion. Result. Murphy's method had the lowest mean femoral neck anteversion (FNA) at 24.98°, while the MSK method had the highest at 28.55°. Bland-Altman plots showed systematic errors between 2D (1.201°) and 3D (1.074°) methods. All methods demonstrated good intra- and inter-user reliability. Significant differences were found between measurement methods and between patient groups. Conclusion. The MSK Hip Planner software proved useful and convenient to measure FNA. Statistically significant differences in FNA were observed between the measurement methods, as well as between patient groups when split by presence of osteoarthritis and cam deformity. Complex joint pathology and altered femoral morphology should be considered by clinicians when deciding which method to use when measuring FNA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 72 - 72
14 Nov 2024
Uvebrant K Andersen C Lim HC Vonk L Åkerlund EL
Full Access

Introduction. Homogenous and consistent preparations of mesenchymal stem cells (MSCs) can be acquired by selecting them for integrin α10β1 (integrin a10-MSCs). Safety and efficacy of intra-articular injection of allogeneic integrin a10-MSCs were shown in two post-traumatic osteoarthritis horse studies. The current study investigated immunomodulatory capacities of human integrin a10-MSCs in vitro and their cell fait after intra-articular injection in rabbits. Method. The concentration of produced immunomodulatory factors was measured after licensing integrin a10-MSCs with pro-inflammatory cytokines. Suppression of T-cell proliferation was determined in co-cultures with carboxyfluorescein N-succinimidyl ester (CFSE) labelled human peripheral blood mononuclear cells (PBMCs) stimulated with anti-CD3/CD28 and measuring the CFSE intensity of CD4+ cells. Macrophage polarization was assessed in co-cultures with differentiated THP-1 cells stimulated with lipopolysaccharide and analysing the M2 macrophage cell surface markers CD163 and CD206. In vivo homing and regeneration were investigated by injecting superparamagnetic iron oxide nanoparticles conjugated with Rhodamine B-labeled human integrin a10-MSCs in rabbits with experimental osteochondral defects. MSC distribution in the joint was followed by MRI and fluorescence microscopy. Result. The production of the immunomodulatory factors indoleamine 2,3-dioxygenase and prostaglandin E2 was increased after inflammatory licensing integrin a10-MSCs. Co-cultures with integrin a10-MSCs suppressed T-cell proliferation and increased the frequency of M2 macrophages. In vivo injected integrin a10-MSCs homed to osteochondral defects and were detected in the repair tissue of the defects up to 10 days after injection, colocalized with aggrecan and type II collagen. Conclusion. This study showed that human integrin a10-MSCs have immunomodulatory capacities and in vivo can home to the site of osteochondral damage and directly participate in cartilage regeneration. This suggests that human integrin α10β1-selected MSCs may be a promising therapy for osteoarthritis with dual mechanisms of action consisting of immunomodulation and homing to damage followed by early engraftment and differentiation into chondrocyte-like cells that deposit hyaline cartilage matrix molecules


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 113 - 113
14 Nov 2024
Giger N Schröder M Arens D Gens L Zeiter S Stoddart M Wehrle E
Full Access

Background. The molecular mechanisms underlying non-union bone fractures largely remain elusive. Recently, spatial transcriptomics approaches for musculoskeletal tissue samples have been developed requiring direct placement of histology sections on barcoded slides. However, Formalin-Fixed-Paraffin-Embedded (FFPE) bone sections have been associated with limited RNA quality and read depth compared to soft tissue. Here, we test spatial transcriptomics workflows based on transcriptomic probe transfer to characterize molecular features discriminating non-union and union bone fractures in mice. Method. Histological sections (n=8) used for spatial transcriptomics (Visium CytAssist FFPE; 10x Genomics, n=4 on glass slides, n=4 on hydrogel-coated slides) were obtained from a fracture healing study in female 20-week-old C57BL/6J mice receiving either a femur osteotomy (0.7mm) or a segmental defect (2.4mm) (license 22/2022, Grisons CH). Sequence alignment and manual segmentation of different tissues (bone, defect region/callus, bone marrow, muscle) were performed using SpaceRanger and LoupeBrowser (10x Genomics). Differential gene expression was performed using DESeq2 (Seurat) followed by Gene-Set-Enrichment-Analysis (GSEA) of Gene Ontology (ClusterProfiler). Group comparison of quality measures was done using a Welch's t-test. Results are given as mean±standard deviation. Result. The quality measures, mean counts, and genes per spot, were significantly ~10× higher for sections on hydrogel slides (counts: 4700±1796, genes: 2389±1170) compared to glass slides (counts: 463±415, genes: 250±223). In challenging tissues like cortical bone, we reached high counts+genes in comparison to published data. Direct comparison of a non-union and union section showed a total of 432 differentially regulated genes, 538 in the defect region/callus. GSEA revealed differential regulation of pathways involved in muscle organ morphogenesis, cartilage development and endochondral ossification. Conclusions. Optimized spatial transcriptomics workflows based on transcriptomic probe transfer enable for improved read depth in musculoskeletal tissue enabling the characterization of molecular features discriminating non-union and union bone fractures. Acknowledgements. AO Foundation (AOTRAUMA), SNSF (PhD salary)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 114 - 114
14 Nov 2024
Yalcinkaya A Tirta M Rathleff MS Iobst C Rahbek O Kold S
Full Access

Introduction. The heterogeneity of outcomes used in the field of lower limb lengthening surgery (LLLS) affects our ability to synthesize evidence. This hampers robust systematic reviews and treatment recommendations for clinical practice. Ultimately this reduces the impact of research for both patients and healthcare professionals. This scoping review aimed to describe the outcomes and outcome measurement instruments (OMIs) used within the field of LLLS. Method. A systematic literature search of WOS, Scopus, Embase, MEDLINE, and the Cochrane Library identified all studies reporting outcomes in children and adults after LLLS. All outcomes and OMIs were extracted verbatim. An iterative process was used to group outcome terms under standardized outcome headings categorized using the COMET Taxonomy of Outcomes. Result. Data saturation was achieved in 2020. A total of 142 studies were included between 2024-2020, reporting 2964 verbatim outcomes with 663 standardized outcome terms collapsed into 119 outcome headings (subdomains). A total of 29 patient-reported and 26 clinician-reported outcome instruments were identified. The most commonly reported outcome was “Lengthening amount”, reported in over 72% of the included studies, while “health-related quality of life” was measured in 16% and all life impact outcomes were reported in 19% of the included studies. Conclusion. A large number of peer-reviewed publications are available, demonstrating that significant resources are being devoted to research on LLLS. However, reported outcomes for people with LLLS are heterogeneous, subject to reporting bias, and vary widely in the definitions and measurement tools used to collect them. Outcomes likely to be important to patients, such as quality of life and measures of physical function, have been neglected. This scoping review identifies a need to standardize outcomes and outcome measures reported on patients recovering from lower limb lengthening surgery; this can be addressed by creating a core set of outcomes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 7 - 7
14 Nov 2024
Cullen D Thompson P Johnson D Lindner C
Full Access

Introduction. Accurate assessment of alignment in pre-operative and post-operative knee radiographs is important for planning and evaluating knee replacement surgery. Existing methods predominantly rely on manual measurements using long-leg radiographs, which are time-consuming to perform and are prone to reliability errors. In this study, we propose a machine-learning-based approach to automatically measure anatomical varus/valgus alignment in pre-operative and post-operative standard AP knee radiographs. Method. We collected a training dataset of 816 pre-operative and 457 one-year post-operative AP knee radiographs of patients who underwent knee replacement surgery. Further, we have collected a separate distinct test dataset with both pre-operative and one-year post-operative radiographs for 376 patients. We manually outlined the distal femur and the proximal tibia/fibula with points to capture the knee joint (including implants in the post-operative images). This included point positions used to permit calculation of the anatomical tibiofemoral angle. We defined varus/valgus as negative/positive deviations from zero. Ground truth measurements were obtained from the manually placed points. We used the training dataset to develop a machine-learning-based automatic system to locate the point positions and derive the automatic measurements. Agreement between the automatic and manual measurements for the test dataset was assessed by intra-class correlation coefficient (ICC), mean absolute difference (MAD) and Bland-Altman analysis. Result. Analysing the agreement between the manual and automated measurements, ICC values were excellent pre-/post-operatively (0.96, CI: 0.94-0.96) / (0.95, CI: 0.95-0.96). Pre-/post-operative MAD values were 1.3°±1.4°SD / 0.7°±0.6°SD. The Bland-Altman analysis showed a pre-/post-operative mean difference (bias) of 0.3°±1.9°SD/-0.02°±0.9°SD, with pre-/post-operative 95% limits of agreement of ±3.7°/±1.8°, respectively. Conclusion. The developed machine-learning-based system demonstrates high accuracy and reliability in automatically measuring anatomical varus/valgus alignment in pre-operative and post-operative knee radiographs. It provides a promising approach for automating the measurement of anatomical alignment without the need for long-leg radiographs. Acknowledgements. This research was funded by the Wellcome Trust [223267/Z/21/Z]


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 17 - 17
14 Nov 2024
Kjærgaard K Ding M Mansourvar M
Full Access

Introduction. Experimental bone research often generates large amounts of histology and histomorphometry data, and the analysis of these data can be time-consuming and trivial. Machine learning offers a viable alternative to manual analysis for measuring e.g. bone volume versus total volume. The objective was to develop a neural network for image segmentation, and to assess the accuracy of this network when applied to ectopic bone formation samples compared to a ground truth. Method. Thirteen tissue slides totaling 114 megapixels of ectopic bone formation were selected for model building. Slides were split into training, validation, and test data, with the test data reserved and only used for the final model assessment. We developed a neural network resembling U-Net that takes 512×512 pixel tiles. To improve model robustness, images were augmented online during training. The network was trained for 3 days on a NVidia Tesla K80 provided by a free online learning platform against ground truth masks annotated by an experienced researcher. Result. During training, the validation accuracy improved and stabilised at approx. 95%. The test accuracy was 96.1 %. Conclusion. Most experiments using ectopic bone formation will yield an inter-observer or inter-method variance of far more than 5%, so the current approach may be a valid and feasible technique for automated image segmentation for large datasets. More data or a consensus-based ground truth may improve training stability and validation accuracy. The code and data of this project are available upon request and will be available online as part of our publication


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 63 - 63
14 Nov 2024
Ritter D Bachmaier S Wijdicks C Raiss P
Full Access

Introduction. The increased prevalence of osteoporosis in the patient population undergoing reverse shoulder arthroplasty (RSA) results in significantly increased complication rates. Mainly demographic and clinical predictors are currently taken into the preoperative assessment for risk stratification without quantification of preoperative computed tomography (CT) data (e.g. bone density). It was hypothesized that preoperative CT bone density measures would provide objective quantification with subsequent classification of the patients’ humeral bone quality. Methods. Thirteen bone density parameters from 345 preoperative CT scans of a clinical RSA cohort represented the data set in this study. The data set was divided into testing (30%) and training data (70%), latter included an 8-fold cross validation. Variable selection was performed by choosing the variables with the highest descriptive value for each correlation clustered variables. Machine learning models were used to improve the clustering (Hierarchical Ward) and classification (Support Vector Machine (SVM)) of bone densities at risk for complications and were compared to a conventional statistical model (Logistic Regression (LR)). Results. Clustering partitioned this cohort (training data set) into a high bone density subgroup consisting of 96 patients and a low bone density subgroup consisting of 146 patients. The optimal number of clusters (n = 2) was determined based on optimization metrics. Discrimination of the cross validated classification model showed comparable performance for the training (accuracy=91.2%; AUC=0.967) and testing data (accuracy=90.5 %; AUC=0.958) while outperforming the conventional statistical model (Logistic Regression (LR)). Local interpretable model-agnostic explanations (LIME) were created for each patient to explain how the predicted output was achieved. Conclusion. The trained and tested model provides preoperative information for surgeons treating patients with potentially poor bone quality. The use of machine learning and patient-specific calibration showed that multiple 3D bone density scores improved accuracy for objective preoperative bone quality assessment


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 33 - 33
14 Nov 2024
Fallahy M Shaker F Ghanbari F Aslani MA Mohammadi S Behrouzieh S
Full Access

Introduction. Knee Osteoarthritis (KOA) is a prevalent joint disease requiring accurate diagnosis and prompt management. The condition occurs due to cartilage deterioration and bone remodeling. Ultrasonography has emerged as a promising modality for diagnosing KOA. Medial meniscus extrusion (MME), characterized by displacement of medial meniscus beyond the joint line has been recognized as a significant marker of KOA progression. This study aimed to explore potentials Ultrasound findings in timely detection of MME and compare it to magnetic resonance imaging (MRI) as a reference standard. Method. A comprehensive literature search was performed in 4 databases from inception to May 1 2024. Two independent reviewers, initiated screening protocols and selected the articles based on inclusion and exclusion criteria and then extracted the data. Meta-analysis was conducted using R 4.3.2 packages mada and metafor. Result. A total of 2500 articles from 4 databases was retrieved; however, following the application of inclusion and exclusion criteria 23 articles were finally extracted. These studies collectively encompassed a total of 777 patients with mean age of 53.2±7.4. The mean BMI calculated for patients was 28.31 ± 2.45. All patients underwent non-weight bearing knee ultrasonography in supine position with 0° flexion. The reported medial meniscus extrusion was 2.58 mm for articles using MRI and 2.65 mm for those using Ultrasound (MD: 0.05 ± 0.12, P= 0.65, I. 2. : 54%). Our meta-analysis revealed insignificant difference between US and MRI. (SMD: 0.03, 95% CI: -0.18 _0.23, P= 0.77, I. 2. : 56%) Meta analysis for diagnostic accuracy measures yielded a pooled sensitivity and specificity of 90.8% and 77% (95% CI: 84.2% – 94.8%, 35.5% – 95.3%, respectively, I. 2. : 44%). Conclusion. Our results indicate a close alignment in the accuracy of measurements obtained using Ultrasound modality. The narrow range suggests a minimal discrepancy in MME values between MRI and ultrasound, highlighting their comparable precision in diagnostic assessments


Introduction. Patellar tendinopathy is a highly prevalent clinical diagnosis supported by ultrasound changes. Numerous interventions are targeted at improving both symptoms and structure of dysfunctional tendons, however little is known of the diagnostic value in a changing ultrasound profile whilst patient reported outcome measures determine recovery. The aim of this study was to assess if change in ultrasound measure is congruent with change in Victorian Institute of Sport Assessment – Patella (VISA-P) score and therefore indicates the use of using ultrasound to assess patellar tendinopathy during symptom change. Method. Four databases (PubMed, Web of Science, Embase, Cinahl) were search in January 2014. Studies selected contained ultrasound and VISA-P scores from ≥ 2 type points. All included studies were quality assessed depending on type and available data underwent meta-analysis. Result. 10 papers of varying study type, of limited to high quality, were synthesised. Meta-analysis indicated that change in ultrasound measure was not congruent with change in VISA-P score. Conclusion. The variation in study quality, along with significant heterogeneity of ultrasound measure outcomes and reporting may influence the congruency of the data, but the association between gradual structure change and varying vascularity with pain or function is questionable throughout tendinopathy literature