Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims

We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry.

Methods

In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims. The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients. Methods. All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m. 2. (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle). Results. The FBow impact on the mMDFA can be measured by the C’KS angle. The C’KS angle took the localization (length DK) and the importance (FBow angle) of the FBow into consideration. The mean FBow angle was 4.4° (SD 2.4; 0 to 12.5). The mean C’KS angle was 1.8° (SD 1.1; 0 to 5.8). Overall, 84 knees (41%) had a severe FBow (> 5°). The radiological measurements showed very good to excellent intraobserver and interobserver agreements. The C’KS increased significantly when the length DK decreased and the FBow angle increased (p < 0.001). Conclusion. The impact of the diaphyseal femoral deformity on the mechanical femoral axis is measured by the C’KS angle, a reliable and reproducible measurement. Cite this article: Bone Jt Open 2023;4(4):262–272


Bone & Joint Open
Vol. 3, Issue 3 | Pages 211 - 217
1 Mar 2022
Hsu C Chen C Wang S Huang J Tong K Huang K

Aims

The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification based on the actual joint line obliquity (aJLO) and wider range of aHKA in the Asian population; second, to test this classification in a cohort of Asians with healthy knees; third, to propose individualized alignment targets for different CPAK types in kinematically aligned (KA) total knee arthroplasty (TKA).

Methods

The CPAK classification was modified by changing the neutral boundaries of aHKA to 0° ± 3° and using aJLO as a new variable. Radiological analysis of 214 healthy knees in 214 Asian individuals was used to assess the distribution and mean value of alignment angles of each phenotype among different classifications based on the coronal plane. Individualized alignment targets were set according to the mean lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) of different knee types.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral femoral bowing angles were 10.5° (SD 5.7°)/6.1° (SD 6.2°). The postoperative mean anterior/lateral bowing values were changed by 8.7° (SD 5.4°)/4.6° (SD 5.9°). Bisphosphonates had been used contemporarily in 115 AFFs (78.2%) for a mean of 52.4 months (1 to 204; SD 45.5) preoperatively. Nailing was performed in 133 AFFs (90.5%), and union was obtained at a mean of 23.6 weeks (7 to 85). Delayed union occurred in 41 (27.9%), and nonunion occurred in 13 (8.8%). Contralateral AFF occurred in 79 patients (53.7%), and the use of a bisphosphonate significantly influenced the occurrence of contralateral AFFs (p = 0.019). Peri-implant fractures occurred in a total of 13 patients (8.8%), and a significant increase was observed in cases with plating (p = 0.021) and high grade of postoperative anterolateral bowing (p = 0.044). Conclusion. The use of a bisphosphonate was found to be a risk factor for contralateral AFF, and high-grade postoperative anterolateral bowing and plate fixation significantly increased the occurrence of peri-implant fractures. Long-term follow-up studies on the bilaterality of AFFs and peri-implant fractures are warranted. Cite this article: Bone Joint J 2021;103-B(11):1648–1655


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1646 - 1647
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1242 - 1247
3 Sep 2020
Hsu P Wu K Lee C Lin S Kuo KN Wang T

Aims

Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth.

Methods

We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 512 - 519
1 Sep 2020
Monzem S Ballester RY Javaheri B Poulet B Sônego DA Pitsillides AA Souza RL

Aims

The processes linking long-term bisphosphonate treatment to atypical fracture remain elusive. To establish a means of exploring this link, we have examined how long-term bisphosphonate treatment with prior ovariectomy modifies femur fracture behaviour and tibia mass and shape in murine bones.

Methods

Three groups (seven per group) of 12-week-old mice were: 1) ovariectomized and 20 weeks thereafter treated weekly for 24 weeks with 100 μm/kg subcutaneous ibandronate (OVX+IBN); 2) ovariectomized (OVX); or 3) sham-operated (SHAM). Quantitative fracture analysis generated biomechanical properties for the femoral neck. Tibiae were microCT scanned and trabecular (proximal metaphysis) and cortical parameters along almost its whole length measured.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 36 - 42
1 Jun 2020
Nishitani K Kuriyama S Nakamura S Umatani N Ito H Matsuda S

Aims

This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes.

Methods

A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 83 - 83
1 Apr 2019
Mullaji A Shetty G
Full Access

Aims. The aims of this retrospective study were to determine the incidence of extra-articular deformities (EADs), and determine their effect on postoperative alignment in knees undergoing mobile-bearing, medial unicompartmental knee arthroplasty (UKA). Patients and Methods. Limb mechanical alignment (hip-knee-ankle angle), coronal bowing of the femoral shaft and proximal tibia vara or medial proximal tibial angle (MPTA) were measured on standing, full-length hip-to-ankle radiographs of 162 patients who underwent 200 mobile-bearing, medial UKAs. Results. Incidence of EAD was 7.5% for coronal femoral bowing of >5°, 67% for proximal tibia vara of >3° (MPTA<87°) and 24.5% for proximal tibia vara of >6° (MPTA<84°). Mean postoperative HKA angle achieved in knees with femoral bowing ≤5° was significantly greater when compared to knees with femoral bowing >5° (p=0.04); in knees with proximal tibia vara ≤3° was significantly greater when compared to knees with proximal tibia vara >3° (p=0.0001) and when compared to knees with proximal tibia vara >6° (p=0.0001). Conclusion. Extra-articular deformities are frequently seen in patients undergoing mobile-bearing medial UKAs, especially in knees with varus deformity>10°. Presence of an EAD significantly affects postoperative mechanical limb alignment achieved when compared to limbs without EAD and may increase the risk of limbs being placed in varus>3° postoperatively. Clinical Relevance. Since the presence of an EAD, especially in knees with varus deformity>10°, may increase the risk of limbs being placed in varus>3° postoperatively and may affect long-term clinical and implant survival outcomes, UKR in such knees should be performed with caution


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 485 - 493
1 Jul 2018
Numata Y Kaneuji A Kerboull L Takahashi E Ichiseki T Fukui K Tsujioka J Kawahara N

Objective

Cement thickness of at least 2 mm is generally associated with more favorable results for the femoral component in cemented hip arthroplasty. However, French-designed stems have shown favorable outcomes even with thin cement mantle. The biomechanical behaviors of a French stem, Charnley-Marcel-Kerboull (CMK) and cement were researched in this study.

Methods

Six polished CMK stems were implanted into a composite femur, and one million times dynamic loading tests were performed. Stem subsidence and the compressive force at the bone-cement interface were measured. Tantalum ball (ball) migration in the cement was analyzed by micro CT


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 89 - 89
1 May 2016
Megahed R Stocks O Ismaily S Stocks G Noble P
Full Access

Introduction. The success of knee replacement surgery depends, in part, on restoration of the correct alignment of the leg with respect to the load-bearing vector passing from the hip to the ankle (the mechanical axis). Conventional thinking is that the correct angle of resection of the distal femur (Valgus Cut Angle, VCA) depends on femoral length or femoral offset, though femoral bowing, in addition to length and medial offset, may also have a significant influence on the VCA. We hypothesized that femoral bowing has a strong effect on the VCA necessary to restore physiologic alignment after arthroplasty or osteotomy. Methods. A total of 102 long-leg radiographs were obtained from patients scheduled for primary total knee arthroplasty. The patients on average were 41% male 59% female, 67.9 ± 11.1 years, 67.0 ± 4.7 in, 192 ± 43 lbs, and had a BMI of 29.7 ± 4.8. All radiographs were prepared with the feet placed in identical rotation and the patellae pointing forward, and were excluded if there was evidence of malrotation, as defined by (i) a difference in the medial head offsets of the right and left femur of >3mm, (ii) a difference in the width of the tibiofibular syndesmoses, or (iii) a difference in the rotation of one foot compared to the other. The following anatomic variables were measured on each radiograph: (i) the neck shaft angle (NSA) of the femur, (ii) the length of the femur, (iii) the length of the femoral shaft, (iv) the medial head offset, (v) the medial-lateral bow of the distal femur, (vi) the hip- knee axis angle, (vii) the mechanical axis deviation of the extremity at the knee, (viii) the medio-lateral bow of the tibia, and (ix) the valgus cut angle required to restore the mechanical axis to the center of the knee during surgery (VCA). Bivariate plots were constructed using the measurements thought to influence the VCA: femoral bowing, femoral offset, and length of femur. Multivariate regression was then used to find the variable that had the strongest effect on the VCA. Results. The bivariate plot of offset and VCA yielded an R2 of 0.02544 (p = 0.11) was not statistically significant. However, the bivariate plot of femoral length and VCA yielded an R2 of 0.1294 (p = 0.0002) showing significant correlation. Lastly, the bivariate plot of femoral bowing and VCA yielded an R2 of 0.59136 (p < 0.00001) demonstrating significant correlation (Figure 3). Multivariate analysis revealed that femoral bowing was the best predictor of VCA: VCA = 5.46–0.363 femoral bowing (°) + 0.106 Femoral offset (mm) − 0.010 femoral length (mm). Discussion. While clinicians performing knee replacements typically do not consider femoral bowing when selecting the valgus angle appropriate for each patient, our findings demonstrate that femoral bowing has a potent effect on VCA. The multivariate regression indicated that femoral bowing had the highest effect on VCA followed by offset and femoral length. These findings suggest that surgeons should consider measuring long alignment radiographs before performing a total knee arthroplasty


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1615 - 1622
1 Dec 2015
Müller M Abdel MP Wassilew GI Duda G Perka C

The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck­shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck–shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes.

In total, 44 patients (mean age 65.3 years (standard deviation (sd) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (sd 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck–shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes.

The mean pre-operative neck–shaft angle was significantly increased by 2.8° from 128° (sd 6.2; 119° to 147°) to 131° (sd 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (sd 8; 7.9 to 39.1) and reduced to 7.4° (sd 7.3; -11.6° to 25.9°) post-operatively (p < 0.001). The post-operative changes had no influence on function and pain. Using a standard uncemented femoral component, high pre- and post-operative variability of femoral anteversion and neck–shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck–shaft angles, but without any impact on clinical outcome.

Cite this article: Bone Joint J 2015;97-B:1615–22.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 30 - 39
1 Oct 2015
Baldini A Castellani L Traverso F Balatri A Balato G Franceschini V

Primary total knee arthroplasty (TKA) is a reliable procedure with reproducible long-term results. Nevertheless, there are conditions related to the type of patient or local conditions of the knee that can make it a difficult procedure. The most common scenarios that make it difficult are discussed in this review. These include patients with many previous operations and incisions, and those with severe coronal deformities, genu recurvatum, a stiff knee, extra-articular deformities and those who have previously undergone osteotomy around the knee and those with chronic dislocation of the patella.

Each condition is analysed according to the characteristics of the patient, the pre-operative planning and the reported outcomes.

When approaching the difficult primary TKA surgeons should use a systematic approach, which begins with the review of the existing literature for each specific clinical situation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):30–9.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 595 - 602
1 May 2015
McCalden RW Korczak A Somerville L Yuan X Naudie DD

This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (sd 1.71) vs 0.32 mm (sd 0.45), p = 0.66; rotation 0.96° (sd 1.49) vs 1.41° (sd 2.95), p = 0.88; and total migration 1.09 mm (sd 1.74) vs 0.73 mm (sd 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem.

Cite this article: Bone Joint J 2015; 97-B:595–602.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 34 - 34
1 Sep 2012
Corten K Jonkergouw F Bartels W Van Lenthe H Bellemans J Simon J Vander Sloten J
Full Access

Summary sentence. The bowing of the femur defines a curvature plane to which the proximal and distal femoral anatomic landmarks have a predictable interrelationship. This plane can be a helpful adjunct for computer navigation to define the pre-operative, non-diseased anatomy of the femur and more particularly the rotational alignment of the femoral component in total knee arthroplasty (TKA). Background and aims. There is very limited knowledge with regards to the sagittal curvature -or bowing- of the femur. It was our aim (1) to determine the most accurate assessment technique to define the femoral bowing, (2) to define the relationships of the curvature plane relative to proximal and distal anatomic landmarks and (3) to assess the position of femoral components of a TKA relative to the femoral bowing. Materials and methods. Four independent algorithms were developed and tested on 3D models of 18 cadaveric femora. A sensitivity study showed that a bisector-based method supplied the most stable results. In order to verify if the curvature plane can be used for TKA alignment, the anteversion angle was determined relative to this plane and compared with anteversion angles defined using the coronal plane. Results. The average curvature of the cadaveric femora was 895.85 mm (SD = 184.53 mm). The mean anteversion angle calculated along the projected mechanical or anatomical axis in the coronal plane were 8.2+/−5.2° and 7.6+/− 4.8°. These angles calculated along the projected mechanical or anatomical axis in the curvature plane were 8.2+/−5.2° and 5.2+/−4.8° respectively (p>0.05). Assessment of the component placement relative to the mechanical axis showed that in the coronal plane, an average deviation of 1.84° was measured. In the sagital plane, the average deviation from the mechanical axis was 2.01°. The components were placed in 1 to 2° of extension relative to the femoral bowing. Discussion. A new and stable algorithm was successfully developed to determine the curvature of the femoral shaft. This curvature was comparable to 2 previously reported curvatures. Our study also demonstrates a predictable interrelationship between the femoral shaft curvature on one side and the rotation of the distal femur on the other side. This finding is of great interest in view of a recent trend amongst knee surgeons to aim at anatomical restoration of the patient's original anatomy. Patient matched cutting blocks as well as patient specific implants are today increasingly considered in daily practice in an attempt to restore the patient's natural anatomy and biomechanics. Computational methods to reverse engineer the pre-diseased status of the knee joint regarding its anatomy and orientation are therefore of great importance. The findings from our study suggest that the femoral shaft's curvature is a helpful adjunct to this. Furthermore, abnormal rotational alignment of an axially malaligned component can be assessed accurately with this new reference plane. However, further research on implementing this algorithm and this plane into clinical practice is mandatory. However, further research on implementing this into clinical practice is required


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 102 - 102
1 Sep 2012
Leibowitz E Logan S Schmidig G Schinski J Kester M Patel A
Full Access

Traditional instrumentation relies on rigid IM rods to determine the distal femoral resection which influences size and orientation of the femoral component. Anterior femoral bowing may unexpectedly affect implant sizing. The purpose of this study was to determine the sensitivity of a flexible rod to the femoral anterior bow versus a traditional rod. A database of 93 Asian bone models from CT images was utilized. The bones were subdivided into those having proximal third, distal third, or overall femoral bows. Only the latter group was selected for further analysis, which consisted of 54 with an average bow of 98cm (±20cm). The rigid and flexible rods were placed iteratively so that the proximal portion of the rod touched the anterior cortical-cancellous boundary and no portion of the rod protruded through that boundary. The flexible rod was allowed to flex, as a substantially thin central portion flexes exclusively in the sagittal plane. The relative angle difference between the position of the flexible and rigid rod were calculated. Three femura were chosen from the subset with bows of 123cm, 100cm and 78cm. The femura showed differences between the rigid and flexible rod of 7.5°, 4.5° while no significant angle measured for the smallest bow. Implants were virtually assembled onto the bones and the greatest bowed femur's component reduced one size from the rigid to the flexible rod orientation. The results of this study show that higher bowed femura yielded larger angular deviations between rigid and flexible rods. For higher bowed femura, the flexible rod allows smaller components to be implanted. The flexible rod serves the same purpose as a conventional rod by defining the distal valgus orientation but allows component orientation in the sagittal plane closer to the femoral bow


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 161 - 161
1 Jun 2012
Mullaji A Shetty G
Full Access

Computer navigation has been advocated as a means to improve limb and component alignment and reduce the number of outliers after total knee arthroplasty (TKA). We aimed to determine the alignment outcomes of 1500 consecutive computer-assisted TKAs performed by a single surgeon, using the same implant, with a minimum 1 year follow-up, and to analyze the outliers. Based on radiographic analysis, 112 limbs (7.5%) in 109 patients with mechanical axis malalignment of > 3° were identified and analyzed. The indication for TKA was osteoarthritis in 107 patients and rheumatoid arthritis in 2 patients. Fifty-eight patients (53%) had undergone simultaneous bilateral TKA and 13 patients (12%) had a BMI >30. Preoperative varus deformity was seen in 100 limbs and valgus deformity in 12 limbs. Thirty limbs (27%) had an extra-articular deformity (2 post HTO limbs, 3 malunited fractures, 1 stress fracture, 21 severe femoral bowing and 3 tibial bowing) and 21 limbs (19%) had severe lateral laxity or subluxation. Thirty-eight limbs (34%) had a preoperative deformity of =10° and 24 limbs (21.5%) had varus or valgus deformity of >20°. Postoperatively, 11 limbs were malaligned at ±3°, 74 limbs at ±4°, 22 limbs at ±5°, 2 limbs at ±6°, and 2 limbs at ±7°. Coronal plane malalignment of > ±3° of the femoral component was seen in 28 limbs, tibial component in 32 limbs, and both femoral and tibial components in 13 limbs. Twenty-six limbs with preoperative varus deformity had a postoperative valgus alignment of >183° and 3 limbs with valgus deformity had a postoperative varus alignment of <177°. The incidence of outliers for postoperative limb alignment was low at 7.5% with the tibial component showing a higher incidence of coronal malalignment. Malalignment may be more common in cases of simultaneous bilateral procedures, preoperative limb alignment of =10°, limbs with extra-articular deformities and severe lateral instability. There was a tendency towards over-correction of the hip-knee-ankle axis in both varus- and valgus-deformed knees. Further detailed statistical analysis of the data will be presented. This is the largest single-surgeon series of consecutive navigated TKAs and consequently the largest analysis of outliers that highlights which knees are likely to fall outside the +3 degrees of acceptable alignment and which therefore behoove the surgeon to exercise greater caution


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 208 - 208
1 Jun 2012
Shah N Adsul A
Full Access

Background Computer navigation is increasingly being recognized as a valuable tool in restoring the mechanical axis post TKR. Its use is as yet not universal due to the costs involved, its availability and the fact that it can be cumbersome and time consuming to use. Additionally it requires the insertion of Schanz pins in the femur as well as the tibia which can be a matter of concern as regards stress fracture and infection. However, it is able to reliably locate the center of the femoral head which is an elusive landmark in the standard method. The center of the ankle involves registration for the medial and lateral malleoli which are subcutaneous and easily palpable. We decided to navigate only the distal femoral cut with a specialized navigation unit called Articular Surface Mounted navigation which does not require the insertion of additional pins through the femur or the tibia. We purposely did not use navigation for the rest of the bony cuts as all the other landmarks i.e. femoral epicondyles, tibial malleoli, and tuberosity etc are all easily palpable. This dramatically reduced the surgical time and increased its user friendliness. We are presenting our results. Aim. To analyse the radiographic results obtained with selective femoral navigation and compare with. standard navigational results from the literature. Non-navigated Knees form personal series. Materials and Methods. We have utilized the ASM navigation for distal femoral cut in 112 knees and obtained long X-rays (scanograms) and routine knee X-rays (AP, Lateral and skyline) to study the mechanical axis and component positioning. We measured the mechanical axis deviation, femoral and tibial angle on AP and lateral films and patellar tilt or subluxation on post-operative X-rays by a digital imaging programme called Image–J. (As suggested by the Knee Society roentgenographic Score). We have compared our results with other navigated series from literature and our own series of non-navigated knees. (113 knees) We also noted the surgical time to perform the operation and the occurrence of any complications. Results. Selective femoral navigation is able to restore the mechanical axis as reliably as other methods of navigation and more reliably than non-navigated knees. On an average, it adds less than 10 minutes to surgical time. Femoral angle, tibial angle patellar tilt and subluxation are similar in both navigated and non-navigated series. Navigation use was not associated with any increased complications and no complication could be ascribed to its use. Selective femoral navigation reduced the outliers in mechanical axis restoration when compared with standard femoral intrameduallry instrumentation. Discussion. Selective distal femoral navigation is a reliable tool in restoring mechanical axis post TKR. It is particularly valuable in knees that have pronounced femoral bowing