Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 169 - 169
1 May 2011
Pino S Bonilla JC Borràs JE Puñet E Vila J Hernandez JA
Full Access

Fractures of the distal radius are the most common bony injuries in the upper extremity, and many treatment Methods: have been described in the literature. External fixation remains a highly versatile method to treat many fracture types involving the distal radius. The primary indications for external fixation include reduction of unstable extra-articular fractures and most intra-articular fractures. The use of adjuvant pinning or mini open procedures can be used when external fixation inadequately reduces the joint line alone, especially with central depressions and highly comminuted injuries. The ease of use of the implants and successful track record make it an extremely versatile tool for treating complex fractures of the distal radius. Purpose: To compare 2 Methods: of surgical treatment for displaced intra-articular fractures of the distal radius: open reduction and internal fixation with dorsal plating (Pi Plate; Synthes, Paoli, PA) versus external fixation with o without K-wires. Methods: We compare a retrospective study about AO type C intra-articular distal radius fractures. The fist group (40 patients) is treated with open reduction and internal fixation with DVR plate ande the second group (65 pacients) is treated with external fixation and K-wires and mini-open reduction. Objective, subjective, and radiographic outcomes were assessed at 2 weeks, 4 to 6 weeks, 10 to 12 weeks, 6 months, and 1- and 2-year intervals. The minimum follow-up period was 6 months; the average follow-up period was 18 months. The principal outcome analyzed was Jakim store that included pain, grip strength, range of motion, complications, and radiographic parameters. The groups were equal with respect to age, gender and fracture subtype. Results: No significant difference was found in the Jakim store outcome. The volar plate group, howevwe, showed a similar complication rate when compared with the external fixator group. The plate group also had similar levels of pain at 1 year when compared with the external fixator group. The external fixator group showed an average grip strength of 92% compared with the normal side and 86% in the volar plate group. Conclusions: At midterm analysis the volar plate group showed a significantly higher complication rate compared with the external fixator group; therefore enrollment in the study was terminated. The volar plate group also showed statistically significant higher levels of pain, and weaker grip strength. Based on these results we can recommend the use of volar plates in treating complex intraarticular fractures of the distal radius


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 384 - 384
1 Jul 2008
Haidar S Joshy S Charity R Ghosh S Tillu A Deshmukh S
Full Access

Purpose: Management of the unstable or comminuted displaced fractures of the distal radius is difficult. We report our experience treating these fractures with AO volar plate fixation. An attempt to introduce a new radiological classification for the accuracy of surgical reduction is made. The classification includes 10 criteria and 100 points. Methods: 124 patients had volar plate fixation performed between June 2000 and May 2003 using AO volar plate. We reviewed clinically and radiologically 101 patients; 60 were type C and 41 were type A (after failed conservative treatment). The average follow up is 37 months (24 – 57). The average age is 46 years (19 – 81). Postoperative regimen consisted of immediate physiotherapy and a wrist splint for three weeks. Cooney’s modification of Green and O’Brien and Sarmiento’s modification of Gartland and Werley were used for clinical assessment. Lidstorm and Frykman used for radiological assessment. Results: At final follow up the means of distal radius parameters were: volar tilt of 9 degrees, radial inclination of 22 degrees, radial height is 11mm and palmer cortical angle of 32 degrees. The mean dorsiflexion was 61 degrees, palmer flexion was 59 degrees, pronation was 80 degrees and supination was 76 degrees. Grip strength was 86 percent of the opposite side. The average DASH score was 13.6. There was 14 poor results, 6 of them had significant loss the initial reduction. There was significant correlation between our classification and the clinical outcome. Conclusion: AO volar plate fixation of unstable distal radius fractures provides strong fixation that maintains reduction and allows early mobilisation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 87 - 87
1 Aug 2020
Gusnowski E Schneider P
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO-OTA distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO-OTA classification or a two-tailed independent samples t-tests for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, six dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO-OTA classification versus six dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9 degrees, SD 9.3, n=257, volar 61.3 degrees, SD 11.5, n=1906) and extension (dorsal 60 degrees, SD 12, n=257, volar 62.8 degrees, SD 11.4, n=1906) were significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5-degrees, which is unlikely to be clinically significant. Additionally, there was no significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 81 - 81
1 Apr 2013
Suganuma S Tada K Segawa T Yamauchi D Tsuchiya H
Full Access

Introduction. The flexor carpi radialis (FCR) approach is widely used for volar plate fixation of distal radius fractures. However, patients sometimes complain of postoperative numbness at the thenar eminence. We propose this is derived from injury to the palmar cutaneous branch of the median nerve (PCBm). Materials and methods. From March 2010 to March 2012, we performed 10 operations of volar plate fixation for distal radius fractures using the FCR approach. We detected the PCBm intraoperatively and investigated the anatomy. Results. On average, the PCBm arises from the median nerve 44 mm proximal to the distal wrist crease. It arose from the radial side of the median nerve in nine cases and the ulnar side in one case. In all cases, it ran between the FCR and the palmaris longus tendon under the antebrachial fascia. Nerve supply to the FCR sheath was not observed in the field of operation. Discussion. Numerous studies report the necessity to preserve the PCBm during carpal tunnel release surgery, but the relationship between the FCR approach and the PCBm has not been emphasized. Our results generally agree with past reports on PCBm anatomy. In our experience, the FCR tendon should be retracted to the ulnar side to prevent PCBm injury. If the FCR tendon is retracted radially, the PCBm should be detected and retracted gently. Some studies report that the PCBm joins the FCR sheath at the level of the distal wrist crease. Thus, the distal sheath incision should not be extended blindly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 43 - 43
1 Feb 2012
Loveday D Sanz L Simison A Morris A
Full Access

The ITS volar radial plate (Implant Technology Systems, Graz/Austria) is a fixation device that allows for the distal locking screws to be fixed at variable angles (70°-110°). This occurs by the different material properties, with the screws (titanium alloy) cutting a thread through the plate holes (titanium). We present our experience with the ITS plate. We retrospectively studied 26 patients who underwent ITS plate fixation for unstable multifragmentary distal radial fractures (AO types A3, B2, B3, C2, C3). The surgery was performed either by a consultant orthopaedic hand surgeon or senior registrar. A volar approach was used every time and 10 cases required synthetic bone grafting. Post-operatively they were immobilised for an average of 2.5 weeks. The 26 patients had a mean age of 58 and the dominant side was affected in 46% of cases. 5 cases were open fractures and 10 cases followed failed manipulation under general anaesthesia. The average interval between injury and surgery was 7 days. Union was achieved in all cases. No implant infections, failure or tendon rupture/irritation occurred. There were two fractures which loss reduction, of which one required revision surgery. There was one case of CRPS. The six month average DASH score was 27.5. We consider the ITS plate a technically easy plate to use and a reliable implant at early follow-up. We value the versatility of its variable angle screw fixation ability for complex intra-articular distal radial fractures


Historically the management of distal radial fracture has been often inadequate. It can be difficult to internally fix complex distal radial fractures with conventional plates. The fracture often collapses with metalwork failure. Literature suggests that malunion may lead to painful wrist with loss of function. In recent years fixed angle locking plate has been advocated for treatment of complex distal radius fracture. Our aim was to assess to assess the effectiveness of the volar locking plate (DePuy) in maintaining fracture reduction in distal radial fractures. Radiographs of 170 distal radius fractures treated by the DVR plate were analysed. Fractures were classified according to the Melone and AO classifications. The post injury, intra-operative, 6 weeks postoperative and final postoperative radiographs were reviewed to obtain measurements for radial height, radial slope and volar inclination. The measurements were correlated with fracture pattern, locking screw length, presence or absence of radial styloid screw and plate placement in relation to the wrist joint. The results were analysed statistically using Wilcoxon signed rank test. Radiologically there was minor loss of radial height, slope and volar inclination but this was not statistically significant. There was a statistically significant correlation between complexity of fracture and loss of radiological parameters. There was no statistically significant correlation between loss of radiological parameters and screw length, plate placement or presence or absence of radial styloid screw. The DVR volar locking plate appears to maintain a satisfactory reduction of the fracture except for some complex fractures with dorsal comminution in which case dorsoradial plates may be preferable


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 75 - 75
1 May 2016
Tarallo L Mugnai R Catani F
Full Access

Background

Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at mean 24-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon (CFR-PEEK) for the treatment of distal radius fractures.

Materials and methods

We performed a prospective study including all patients who were treated for unstable distal radius fracture with a CFR-PEEK volar fixed angle plate. We included 70 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 35 fractures were type C1, 13 were type C2, 6 were type C3, 5 were type B1 and 11 were type B2.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 2 - 2
1 Sep 2014
van der Kaag M Ikram A
Full Access

Aims of study. To assess and compare the functional, radiological and cosmetic results as well as patient satisfaction in patients treated with the IMN Device Vs Volar Locking Plate. Method. All patients who presented to our institution with extra articular distal radius fractures and met the inclusion criteria were invited to take part in the study. The patients were randomly allocated to two groups, those who underwent intramedullary (IMN) distal radius fixation using the Sanoma Wrx Distal radius nail and those who underwent fixation using a volar locking plate. The patients were then followed up at 2 weeks, 6 weeks, 3 months, 6 months and 1 year. The radiological parameters, ie radial height, inclination and tilt were compared as well as the functional outcomes by means of DASH score. The range of motion of the wrist was compared as well as the scar size. Complications were reviewed. Results. We present our early results. Currently we have included 9 patients in the IMN group and 7 patients in the volar plate group with follow-ups longer than 3 months. Results show smaller scars (2.5 vs 6.7cm), comparable flexion and extension (40 vs 40 and 45 vs 40), slight improvements in pronation and supination (80 vs 75 and 85 vs 80) in the IMN compared to the volar plate. Radial and ulnar deviation is comparable. The radiological parameters showed slight improvements in the radial height (2.5 vs 2.2 mm), inclination (3.6 vs 3.2 degrees) and tilt 13,7 vs 12 degrees) with the IMN. Dash scores will be compared at 6 months. Conclusion. Intra medullary nailing of the distal radius seems to compare to volar plating in terms of radiological parameters and rotational stability but has the added benefit of early range of motion, minimal invasive technique, less post op pain and less complications such as tendon irritation. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 22 - 22
1 Feb 2013
Elkhouly A Roy N
Full Access

Objective. The aim of this retrospective study is to assess the functional and radiological outcome of a multi-planar corrective osteotomy, distraction and locking fixed angle volar plate as the standard of treatment of distal radius mal-unions that require multi-planar correction. Methods. We conducted a retrospective study on 13 consecutive patients – 4 males, 9 females (mean age 49). All patients underwent volar approach, open wedge distraction osteotomy locking fixed angle volar plate and cancellous bone grafting Radiographic measurements and functional assessments were taken preoperatively, 3, 6 months and one year. Results. Time to surgery from the original fracture had a mean of 17.4 months (range 8–36 months). Mean follow-up was 16.4 months (range from 6 to 45 months). Osteotomy healing time was 11.3 weeks on average. All radiographic measurements improved postoperatively, ten patients had an average of 18.84 degrees of dorsal tilt which was corrected to a volar tilt of 9.17 degrees on average. Ulna variance was initially positive in all patients with an average of 2.6 mm which was corrected to less than one (0.96 mm); three patients had radial angulations of 20.6 degrees on average, which were fully corrected postoperatively. Flexion-extension arc has improved with significant difference and so has the grip and pinch strength. The average DASH and SF12 scores has shown figures comparative to the normal population post deformity correction. Complications included one case of low grade wound infection and one case of postoperative symptoms of carpal tunnel syndrome. Conclusion. The described technique is a useful means to correct distal radius anatomy and function; however patients should be aware that it is not always possible to regain full function and anatomy


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 525 - 526
1 Nov 2011
Chirpaz-Cerbat J Ruatti S
Full Access

Purpose of the study: Defective reduction and secondary displacement after osteosynthesis of distal radius fractures can compromise wrist function. Volar locking plates enable solid fixation which remains stable over time but section of the pronator quadrates necessary for the anterior approach raises the risks of destabilising the distal radioulnar joint and loss of pronation force. Our study was designed to evaluate recovery of grip, pronation and supination force after volar locking plate fixation. Material and methods: This was a prospective study of 29 fractures of the distal radius with dorsal displacement fixed with a volar locking plate in 28 patients (17 men, 11 women, mean age 48.75 years) from January 2007 to May 2008. The quality of the pronator quadrates suture was assessed at the end of the operation. The assessment included the classical parameters of wrist movement, the Herzberg and Dumontier score, radial slope and ulnar variance on the ap and lateral views of the wrist, and recovery of grip, pronation and supination force compared with the opposite side using an ambulatory device. Results: The pronator quadratus suture was considered solid in eight cases, precarious in seven. Complete suture was not possible in 14 cases. At mean follow-up of 10 months, patients had on average recovered 77% of the grip force, 74% of the pronation force, and 76% of supination force, compared with the opposite side. Complications included one defective reduction, one secondary displacement (by defective plate position), two dystrophy syndromes, and four posttrauma carpal tunnel syndromes. Discussion: The literature shows that volar plate fixation enables recovery of 74% to 84% of grip force. Few studies have examined the recovery of pronosupination and none have described results after osteosynthesis for fracture. Our study did not find that section of the pronator quadrates, a muscle difficult to suture, had a deleterious effect. Conclusion: Osteosynthesis using a volar locking plate for distal fractures of the radius remains a controversial issue. Study of recovery of the grip, pronation and supination force did not reveal any prejudice attributable to this technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study. With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 277 - 277
1 Jul 2008
OBERT L LECLERC G CLAPPAZ P LEPAGE D BONIN N JEUNET L
Full Access

Purpose of the study: Appropriate treatment for fractures of the distal radius with dorsal displacement remains a subject of debate. Intrafocal pinning is the most widely used technique in France. Plate fixation has been developed to avoid secondary displacement and stiffness sometimes observed after pinning. We compared three osteosynthesis techniques for the same type of fracture (extra-articular with dorsal displacement).

Material and methods: Sixty-two consecutive patients underwent osteosynthesis using the following techniques successively: posterior plates [20 patients mean age 59.9 years (range 25–87 years)], intra and extra-focal pînning [22 patients mean age 55.6 years (range17–83 years)], the anterior plate [20 patients mean age 57.1 years (range 17–78 years)]. An independent operator evaluated all patients using the Herzberg, Gartland and Werley and Dash scores. The radial slope in the frontal plane, sagittal tilt, and ulnar variance were measured and compared between the preoperative and last follow-up values. Kruskall-Wallis or ANOVA were applied as appropriate for continuous variables and the chi-square test for non-continuous variables. P< 0.05 was considered significant.

Results: Mean operative time was equivalent for the two plate fixation techniques and twice as long as for pinning. There were more complications in the posterior plating group (32%) and less satisfactory function score despite a two-fold longer follow-up and a smaller number of operators. The best results were obtained with the anterior plating group in terms of range of motion (flexion-extension), Dash, preservation of ulnar variance and presence of a largest number of excellent and very good outcomes according to Gartland. The pinning group provided the best results in terms of sagittal slope. The pinning and anterior plating groups had equivalent range of motion for supination pronation and the same rate of complications (5%). Irrespective of the treatment arm, the Herzberg scores and the Gartland and Dash scores were better: in men, in patients aged less than 30 years, in patients with an associated fracture of the apex of the ulnar syloid process rather than its base.

Discussion: While posterior plate fixation is logical (approach on the side of the injury), the technique is difficult and can lead to nerve and tendon complications. For these extra-articular fractures, pinning like anterior plating can provide good functional results. Pinning is a rapid procedure and anterior plates do not have to be removed, allowing more rapid recovery of total independence.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 169 - 169
1 May 2011
Cheung G Miller D Wilson L Meyer C Kerin C Ford D
Full Access

The treatment of unstable distal radius fractures remains controversial. Volar locking plates provide stable fixation using the fixed angle device principle. More recently this technique has gained increasing popularity with several reports demonstrating good results. We present our experience from the first 259 patients performed at this institution. Method: Local Ethics Committee approval was obtained prior to the onset of the study. Theatre records and implant forms were used to recruit all patients in whom a Distal Volar Radius (DVR) Plate, (DePuy, Leeds, United Kingdom) was used for an unstable distal radius fracture between August 2005 and February 2008. Surgery was performed either by a consultant, or a specialist registrar. Two hundred and fifty nine consecutive patients were identified. Six patients had bilateral distal radius fractures. Patient records were reviewed, and each patient contacted via a postal questionnaire and Patient-Rated Wrist Evaluation (PRWE). Other outcome measures included return to work and complication rate. Results: Of the 259 patients 160 responses were received, response rate 62%. The mean follow up was 30.8 months, (Range 18–48). The mean age of the patients was 57.3 years (Range 16–93). The mean inpatient stay was 1.6 days, (mode 1 day). The median PRWE was 3; (range 0–83) and the mode was 0. Ninety four of the patients had a PRWE of ≤5. Seventy one out of 78 patients (91%) returned to the same job. The mean return to work was 40.6 days (SD37.5). There were 13 minor complications in total (7.8%). Six patients had extensor tendon irritation, of which two patients required extensor tendon reconstruction. One further patient had a spontaneous EPL rupture which was not associated with prominent metal work. Four (2.4%) patients had median nerve symptoms postoperatively. Two patients subsequently required carpal tunnel decompression, the other two settled spontaneously. Two (1.2%), patients developed Complex Regional Pain Syndrome. One patient developed a minor superficial wound infection. In all, 9 (5.4%) patients had removal of their metalwork, 6 for tendon irritation, 2 for wrist stiffness (one which was positioned too distally) and 1 for pin penetration into the joint. Discussion: Our results show that the DVR plate can be used reliably with good results and an early return to high levels of function. This is the largest series to date of the use of this distal volar locking plate


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 177 - 178
1 Mar 2009
Tate R Broadbent M Carnegie C Christie E Johnstone A
Full Access

Aims: In recent years, volar locking plates have increased in popularity for the treatment of displaced distal radial fractures. The angular stability of the screws help maintain reduction permitting early mobilisation. The aim of this study was to assess functional outcome using both subjective and objective methods. Methods: The study was a prospective cohort study. Over a 2 year period 110 patients with closed, displaced distal radial fractures were considered suitable for treatment with the distal radius volar locking plate. Of these, 51 patients were followed up for a full 12 months. One year post-operatively all patients were reviewed and both subjective and objective measurements made:. Subjective:. Pain – visual analogue scale (VAS) (0 = no pain, 10 = worst pain ever). Overall function – patients’ perception – VAS (0 = no function, 100 = full function). Objective: Strength – grip and pinch – measured objectively as a percentage of the uninjured side. Range of Motion – Flexion, extension, pronation and supination – measured objectively as percentages of the uninjured side. For the purpose of this analysis, the fractures were divided into intra- and extra-articular fracture patterns based on the initial pre-operative X-rays. Results: The mean age was 55 years (28 – 83), 36 were female and 15 male. Of the fractures, 26 were extra-articular and 25 intra-articular. 28 of the 51 patients had a period of physiotherapy post-operatively. 23 patients were either not referred to physiotherapy or failed to attend. Subjectively 75% of patients had an excellent result with a pain VAS score of 0–1/10 (mean 0.9 for extra-articular and 1.2 for intra-articular) and an overall function VAS score of 9–10/10 (mean 92% for extra-articular and 86% for intra-articular). Objective outcome measures were also very good. The results for the extra-articular group showed a mean grip strength of 85%, a mean pinch grip of 91%, a mean flexion of 82%, a mean extension of 88%, a mean pronation of 98% and a mean supination of 98%. The results for intra-articular fractures showed a mean grip strength of 80%, a mean pinch grip of 88%, a mean flexion of 78%, a mean extension of 83%, a mean pronation of 94% and a mean supination of 93%. Conclusions: Overall patients made an excellent recovery. The majority of patients had little or no pain and almost complete return to function at 12 months post-operatively. Interestingly, individual patient demographics (age, sex, fracture type, physiotherapy) did not make a statistically significant difference to the outcome measures. This study confirmed excellent functional results comparable with other methods of fixation for extra-articular fractures, but it also showed good results with the more complex intra-articular fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 87 - 87
1 Jul 2020
Ashjaee N Johnston G Johnston J
Full Access

Distal radius fracture is one of the most common fractures in older women (∼70,000 cases annually in Canada). Treatment of this fracture has been shifting toward surgery (mainly volar locking plate (VLP) technology), which significantly enhances surgeon's ability to maintain correction. However, current surgical outcomes are far from perfect. There is a need for an implant which maintains the corrected position (reduction), minimizes soft tissue disruption, and is technically easy to perform. A novel internal, composite-based implant was designed to achieve these ends. It is unclear, however, whether this novel implant offers similar fracture fixation as the VLP. As such, the objective of this research was to evaluate the fracture stability (assessed by calculating change in fracture length) of the novel implant and VLP under cyclic fatigue loading. Specimens: Seven radius specimens derived from older female cadavers (mean = 82.3 years, SD = 11.3 years) were used for the experiment. Preparation: A standardized dorsal wedge was removed from the cortex. The distance from the proximal and distal transverse osteotomies was 10 mm and was positioned 20 mm proximal to the tip of the radial styloid. The osteotomy removed all load-bearing capabilities of bone, equivalent to a worst-case-scenario for DRF fixation. Simulated Loading: The proximal end of the radii was potted (fixed) and positioned in a material testing system. To mimic natural loading conditions, hands were cycled between −30°/30° flexion/extension, at 0.5 Hz, for 2000 cycles, while tension load was applied to the tendons (25-N constant force per tendon, 100-N in total). Mechanical testing outcomes: A position tracking sensor used to measure change in fracture length. This change, as a function of number of cycles, was used to assess implant resistance to fatigue loading. Statistical Analysis: A paired student t-test was used to compare the change in fracture length. Level of significance was determined as 5% (p < 0.05). Changes in fracture fracture-length for both the novel implant and plate is shown in Table 1. The paired t-test indicated significant differences between the two groups in terms of change in fracture length (p = 0.026). The outcome of the novel implant ranged from very stable (change in fracture-length = 0.01 mm) to highly un-stable (2.88 mm). We believe the reason for this variance, at least in part, originates from the surgical procedures. Presumably, given that one very strong stabilization (0.01 mm) and one acceptable stabilization (0.37 mm) was obtained, future research directed towards surgical procedures may improve fracture stability. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 86 - 86
1 Jul 2020
Ashjaee N Johnston G Johnston J
Full Access

Distal radius fractures are the most common osteoporotic fractures among women. The treatment of these fractures has been shifting from a traditional non-operative approach to surgery, using volar locking plate (VLP) technology. Surgery, however, is not without risk, complications including failure to restore an anatomic reduction, fracture re-displacement, and tendon rupture. The VLP implant is also marked by bone loss due to stress-shielding related to its high stiffness relative to adjacent bone. Recently, a novel internal, composite-based implant, with a stiffness less than the VLP, was designed to eradicate the shortcomings associated with the VLP implant. It is unclear, however, what effect this less-stiff implant will have upon adjacent bone density distributions long-term. The objective of this study was to evaluate the long-term effects of the two implants (the novel surgical implant and the gold-standard VLP) by using subject-specific finite element (FE) models integrated with an adaptive bone formation/resorption algorithm. Specimen: One fresh-frozen human forearm specimen (female, age = 84 years old) was imaged using CT and was used to create a subject-specific FE model of the radius. Finite element modeling: In order to simulate a clinically relevant (unstable) fracture of the distal radius, a wedge of bone was removed from the model, which was approximately 10 mm wide and centered 20 mm proximal to the tip of the radial styloid. Bone remodeling algorithm: A strain-energy density (SED) based bone remodeling theory was used to account for bone remodeling. With this approach, bone density decreased linearly when SED per bone density was less than 67.5 µJ/g and increased when it was more than 232.5 µJ/g. When it was in the lazy zone (67.5 to 232.5 µJ/g), no changes in density occurred. Boundary conditions: A 180 N quasi-static force representing the scaphoid, and a 120 N quasi-static force representing the lunate was applied to the radius. The midshaft of the radius was constrained. FE outcomes: To examine the effects of stress shielding associated with each implant, the long-term changes of bone density within proximal transverse cross-sections of radius were inspected. The regional density analysis focused on three transverse cross-sections. The transverse cross-sections were positioned proximal to the subchondral plate, and were distanced 50 (cross-section A), 57 (cross-section B), and 64 mm (cross-section C) from the subchondral endplate. For both implants in all three cross-sections, cortical bone was reserved completely at the volar side. On the dorsal side, the cortical bone was completely resorbed in the VLP model. In all cross-sections, the averaged resultant density was higher for the “novel implant”. The difference ranged from 33% (cross-section A) to 36% (cross-section C) in favor of the “novel implant”. On average, the density values of the novel implant were 34% higher in transverse cross-sections (A, B, and C). This study showed that the novel implant offered higher density distributions compared to the VLP, which suggests that the novel implant may be superior to the VLP in terms of avoiding stress shielding


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 103 - 103
1 Mar 2012
McFadyen I Curwen C Field J
Full Access

The aim of this study is to compare functional, clinical and radiological outcomes in K-wire fixation versus volar fixed-angle plate fixation in unstable, dorsally angulated distal radius fractures. Fifty-four adult patients with an isolated closed, unilateral, unstable, distal radius fracture were recruited to participate in the study. Only dorsally displaced fractures with no articular comminution were included. Patients were randomised to have their fracture treated with either closed reduction and K-wire fixation (3 wires) or fixed-angle volar plating. Both groups were immobilised in a below elbow cast for six weeks. The wires removed in the outpatients at six weeks and both groups were referred for physiotherapy. Independent clinical review was performed at three and six months post injury. Functional scoring was performed using the DASH and Gartland and Werley scoring systems. Radiographs were evaluated by an independent orthopaedic surgeon. Twenty-five patients were treated with a plate and twenty-nine with wires. There were no complications in the plate group. There were 9 complications in the K-wire group with 3 patients requiring a second operation (1 corrective osteotomy for malunion, 1 median nerve decompression and 1 retrieval of a migrated wire). The remaining complications included: 5 pin site infections (3 treated with early pin removal and 2 with oral antibiotics only), and 1 superficial radial nerve palsy. There were no tendon ruptures. Both groups scored satisfactory functional results with no statistical difference. There was a statistically significant difference in the radiological outcomes with the plate group achieving better results. We conclude that in unstable dorsally angulated distal radius fractures volar fixed-angle plate fixation is able to achieve comparable functional results to K-wire fixation with better radiological results and fewer complications. This has resulted in a change in our clinical practice


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 136 - 136
1 Feb 2012
McCullough L Carnegie C Christie C Johnstone A
Full Access

Despite the variety of implants or techniques that exist to treat displaced distal radial fractures, the majority fail to provide sufficient stability to permit early functional recovery. However, locking plates have the advantage over other implants in that locking screws add considerably to the overall stability. The aim of this study was to assess the functional outcome of patients with displaced distal radial fractures treated with a volar distal radial locking plate (Synthes). During a two year period, details of 98 patients admitted to our unit with inherently unstable dorsally displaced distal radial fractures treated with volar locking plates were collected prospectively. For the purpose of this analysis, only those patients (55) with unilateral fracture, able to attend the study clinic at 6 months post-injury were considered. Patients were immobilised in wool and crepe for a 2 week period. The group consisted of 15 males and 40 females with an average age of 54 (28 to 83). At 6 months, patients' perceived functional recovery averaged 80%. Objective assessment was considered in relation to the uninjured side: grip strength 73%; pinch strength 83%; palmarflexion 77%, dorsiflexion 80%; radial deviation 74%; ulnar deviation 74%; pronation 93%, and supination 92%. Seven patients complained of symptoms relating to prominent metalwork. Good/excellent early subjective and objective functional recovery was made following open reduction and internal fixation using volar locking plates of dorsally displaced distal radial fractures. We suggest that objective assessment of grip strength and dorsiflexion can be used as a measure of patient perception of function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 5 - 5
1 Jun 2012
Higgs Z Sianos G
Full Access

The study looked at early outcomes of 55 patients who underwent open reduction and internal fixation of distal radius fracture with a single variable angle volar locking plate (Variax, Stryker), by a single surgeon (GS), between May 2007 and December 2008. A retrospective review of notes and radiographs was performed. Twenty-nine women and 26 men were included. The mean age was 52 years. Mean follow up time was 3 months. The dominant wrist was involved in 38 patients. The mechanism of injury was of low energy in 38 patients and of high energy in 17 patients. All patients had comminuted fractures and 52 patients had intraarticular fractures. Seven patients underwent intraoperative carpal tunnel decompression. At latest follow up, active wrist motion averaged 37° extension, 40° flexion, 70° pronation, and 56° supination. Grip strength averaged 64% and pinch grip 77% of the contralateral wrist. Postoperative complications included one flexor pollicis longus rupture, one malunion and three patients with loosening of screws. There was a higher rate of complications seen in patients with high energy injuries. These early results suggest that volar plating with a variable angle plate is an effective treatment option, especially for complex intraarticular distal radius fractures. A medium term outcomes study of a larger number of patients is planned