Abstract
The study looked at early outcomes of 55 patients who underwent open reduction and internal fixation of distal radius fracture with a single variable angle volar locking plate (Variax, Stryker), by a single surgeon (GS), between May 2007 and December 2008.
A retrospective review of notes and radiographs was performed. Twenty-nine women and 26 men were included. The mean age was 52 years. Mean follow up time was 3 months. The dominant wrist was involved in 38 patients. The mechanism of injury was of low energy in 38 patients and of high energy in 17 patients. All patients had comminuted fractures and 52 patients had intraarticular fractures. Seven patients underwent intraoperative carpal tunnel decompression.
At latest follow up, active wrist motion averaged 37° extension, 40° flexion, 70° pronation, and 56° supination. Grip strength averaged 64% and pinch grip 77% of the contralateral wrist. Postoperative complications included one flexor pollicis longus rupture, one malunion and three patients with loosening of screws. There was a higher rate of complications seen in patients with high energy injuries.
These early results suggest that volar plating with a variable angle plate is an effective treatment option, especially for complex intraarticular distal radius fractures. A medium term outcomes study of a larger number of patients is planned.