header advert
Results 1 - 42 of 42
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 43 - 43
23 Jun 2023
Carender CN Taunton MJ Fruth KM Pagnano MW Abdel MP
Full Access

There is a paucity of mid-term data on modular dual-mobility (MDM) constructs versus large (≥40 mm) femoral heads (LFH) in revision total hip arthroplasties (THAs). The purpose of this study was to update our prior series at 10 years, with specific emphasis on survivorships free of re-revision for dislocation, any re-revision, and dislocation.

We identified 300 revision THAs performed at a single tertiary care academic institution from 2011 to 2014. Aseptic loosening of the acetabular component (n=65), dislocation (n=59), and reimplantation as part of a two-stage exchange protocol (n=57) were the most common reasons for index revision. Dual-mobility constructs were used in 124 cases, and LFH were used in 176 cases. Mean age was 66 years, mean BMI was 31 kg/m2, and 45% were female. Mean follow-up was 7 years.

The 10-year survivorship free of re-revision for dislocation was 97% in the MDM cohort and 91% in the LFH cohort with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 5.2; p=0.03). The 10-year survivorship free of any re-revision was 90% in the MDM cohort and 84% in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.5; p=0.04). The 10-year survivorship free of any dislocation was 92% in the MDM cohort and 87% in the LFH cohort. There was a trend towards an increased risk of any dislocation in the LFH cohort (HR 2.3; p=0.06).

In this head-to-head comparison, revision THAs using MDM constructs had a significantly lower risk of re-revision for dislocation compared to LFH at 10 years. In addition, there was a trend towards lower risk of any dislocation.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 48 - 48
23 Jun 2023
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP
Full Access

There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems.

We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized.

The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up.

This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 3 - 3
23 Jun 2023
Berdis GE Couch CG Larson DR Bedard NA Berry DJ Lewallen DG Abdel MP
Full Access

Cup-cage constructs are one of several methods commonly used to treat severe acetabular bone loss during contemporary revision total hip arthroplasty. The purpose of this study was to provide a long-term results of the technique with emphasis on implant survivorship, radiographic results, and clinical outcomes for both full and half cup-cage reconstructions.

We identified 57 patients treated with a cup-cage reconstruction for major acetabular bone loss between 2002–2012. All patients had Paprosky Type 2B through 3B bone loss, with 60% having an associated pelvic discontinuity. Thirty-one patients received a full cup-cage construct, and 26 a half cup-cage. Mean age at reconstruction was 66 years, 75% were female, and the mean BMI was 27 kg/m2. Mean follow-up was 10 years.

The 10-year cumulative incidences of any revision were 14% and 12% for the full and half cup-cage construct groups, respectively. Of the 9 revisions, 3 were for dislocation, 2 for aseptic loosening and construct failure (both were pelvic discontinuities), 1 for adverse local tissue reaction, and 1 for infection with persistent pelvic discontinuity. The 10-year cumulative incidences of revision for aseptic loosening were 4.5% and 5% for the full and half cup-cage constructs, respectively. Of the unrevised cases, incomplete and non-progressive zone 3 radiolucent lines were observed in 10% of patients in each group. Three patients experienced partial motor and sensory sciatic nerve palsies (2 in the full and 1 in the half cup-cage group). Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip scores.

Full and half cup-cage reconstructions for major acetabular defects were successful at 10 years in regards to acetabular fixation without appreciable differences between the two techniques. However, zone 3 radiolucent lines were not uncommon in association with discontinuities, and dislocation continues to be a problem.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 74 - 74
23 Jun 2023
Wilson JM Maradit-Kremers H Abdel MP Berry DJ Mabry TM Pagnano MW Perry KI Sierra RJ Taunton MJ Trousdale RT Lewallen DG
Full Access

The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve implant survivorship. The purpose of the present study was to evaluate survival of contemporary cementless acetabular components following primary THA.

16,421 primary THAs performed for osteoarthritis between 2000 and 2019 were identified from our institutional total joint registry. Patients received one of 12 contemporary cementless acetabular designs with HXLPE liners. Components were grouped based on ingrowth surface into 4 categories: porous titanium (n=10,952, mean follow-up 5 years), porous tantalum (n=1223, mean follow-up 5 years), metal mesh (n=2680, mean follow-up 6.5 years), and hydroxyapatite (HA) coated (n=1566, mean follow-up 2.4 years). Kaplan-Meier analyses were performed to assess the survivorship free of acetabular revision. A historical series of 182 Harris-Galante-1 (HG-1) acetabular components was used as reference.

The 15-year survivorship free of acetabular revision was >97% for all 4 contemporary cohorts. Compared to historical control, porous titanium (HR 0.06, 95% CI 0.02–0.17, p<0.001), porous tantalum (HR 0.09, 95%CI 0.03–0.29, p<0.001), metal mesh (HR 0.11, 95%CI 0.04–0.31, p<0.001), and HA-coated (HR 0.14, 95%CI 0.04–0.48, p=0.002) ingrowth surfaces had significantly lower risk of any acetabular revision. There were 16 cases (0.1%) of acetabular aseptic loosening that occurred in 8 (0.07%) porous titanium, 5 (0.2%) metal mesh, and 3 (0.2%) HA-coated acetabular components. 7 of the 8 porous titanium aseptic loosening cases occurred in one known problematic design. There were no cases of aseptic loosening in the porous tantalum group.

Modern acetabular ingrowth surfaces and HXLPE liners have improved on historical results at the mid-term. Contemporary designs have extraordinarily high revision-free survivorship, and aseptic loosening is now a rare complication.

At mid-term follow-up, survivorship of contemporary uncemented acetabular components is excellent and aseptic loosening occurs in a very small minority of patients.


Bone & Joint Research
Vol. 12, Issue 1 | Pages 58 - 71
17 Jan 2023
Dagneaux L Limberg AK Owen AR Bettencourt JW Dudakovic A Bayram B Gades NM Sanchez-Sotelo J Berry DJ van Wijnen A Morrey ME Abdel MP

Aims

As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA).

Methods

Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury. Biomechanical data were collected to measure passive extension angle (PEA). Histological data measuring area and thickness of posterior and anterior knee capsules were collected from knee sections.


Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims

Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release.

Methods

A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 921 - 925
9 Nov 2021
Limberg AK Wyles CC Taunton MJ Hanssen AD Pagnano MW Abdel MP

Aims

Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs).

Methods

Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m2 (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 2 - 2
1 Oct 2020
Uvodich ME Dugdale EM Taunton MJ Pagnano MW Berry DJ Abdel MP
Full Access

Introduction

Diagnosing acute postoperative periprosthetic joint infections (PJIs) after primary total knee arthroplasties (TKAs) remains difficult. Published diagnostic thresholds for ESR, CRP, and synovial fluid analysis have not been replicated. We aimed to validate the optimal cutoffs for detecting acute postoperative PJIs in a large series of primary TKAs.

Methods

We retrospectively identified 27,066 primary TKAs performed between 2000–2019. Within 12 weeks, 171 knees (170 patients) had a synovial fluid aspiration. Patients were divided into two groups: evaluation <6 weeks or 6–12 weeks. The 2011 MSIS criteria for PJI diagnosed infection in 22 knees. Mann-Whitney U tests compared medians; ROC analyses determined optimal thresholds. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 51 - 51
1 Oct 2020
Wooster BM Kennedy NI Mallet KE Taunton MJ Abdel MP Trousdale RT
Full Access

Introduction

Mechanical or corrosive failure of total knee arthroplasties (TKAs) is difficult to diagnose with current laboratory and radiographic analyses. As such, the goal of this study was to determine the mean blood concentration of cobalt, chromium, and titanium in a series of revision TKAs with mechanical implant failure and evaluate whether they facilitated identification of the underlying TKA failure mechanism.

Methods

Serum cobalt, chromium, and titanium levels and synovial fluid characteristics were evaluated in 12 patients (13 aseptic revision TKAs) who underwent revision TKA between 2000 and 2020 at a single academic institution for mechanical implant failure or corrosion. Seventy-five percent were re-revisions of previously revised TKAs. Mean time to revision was 6 years. Modular metallic junctions were present in 100%. Twenty-five percent did not have another in situ total joint arthroplasty, and the remaining patients did not have a metal-on-metal articulation that could lead to elevation in serum metal ion levels. Mean follow-up after the revision TKA was 8 months.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 3 - 3
1 Oct 2020
Wellings EP Couch CG Taunton MJ Pagnano MW Berry DJ Abdel MP
Full Access

Introduction

Patients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study was to assess implant survivorship, radiographic results, and clinical outcomes of contemporary, non-tantalum, porous acetabular components in the setting of prior pelvic radiation.

Methods

We retrospectively reviewed 33 patients (38 hips) with prior therapeutic pelvic radiation between 2006 and 2016 who underwent primary THA. The mean overall pelvic radiation dose was 6300 cGy with a mean latency period to THA of 5 years. The most common acetabular component was Pinnacle (Depuy-Synthes) in 76%, followed by Trident (Stryker) in 8%, Tritanium (Stryker) in 8%, Trilogy (Zimmer-Biomet) in 5%, and G7 (Zimmer-Biomet) in 3%. Eighty-seven percent of cups were fixed with screws, of which the mean number used was 3. The mean age at primary THA was 74 years, 76% were male, and the mean BMI was 30 kg/m2. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 12 - 12
1 Oct 2020
Wooster BM Abdel MP Berry DJ Pagnano MW
Full Access

Introduction

Arthrofibrosis remains a persistent complication following total knee arthroplasty (TKA). Although manipulation under anesthesia (MUA) is an effective early treatment, the risks and value of this procedure beyond 3 months after TKA remain controversial. The purpose of this study was to examine the safety and efficacy of late MUAs for arthrofibrosis.

Methods

From our institutional total joint registry, 82 TKAs (77 patients) who underwent MUA >3 months after primary (83%) or revision (17%) TKA were identified. Mean time to MUA was 7 months: 66% performed between 4–6 months, 18% between 7–12 months, 16% beyond 12 months. MUAs were coupled with arthroscopic assistance in 26% (12% limited lysis of adhesions, 13% formal arthroscopic debridement). Mean age was 61 years, 59% females, and mean BMI was 33kg/m2. Mean follow-up was 5 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 9 - 9
1 Oct 2020
Gausden EB Shirley M Abdel MP Sierra RJ
Full Access

Background

There are limited data on the complication rates and risk of periprosthetic joint infection (PJI) in patients who have an acute wound dehiscence after total knee arthroplasty (TKA).

Methods

From 2002 to 2018, 16,134 primary TKAs were performed at a single institution. Twenty-six patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68, 38% were female, and mean BMI was 33 kg/m2. Median time to dehiscence was 13 days. The dehiscence resulted from a fall in 22 cases, including 4 in-hospital falls (3 with femoral nerve blocks), and sudden flexion after staple removal in 4 cases. The arthrotomy was disrupted in 58%, including a complete extensor mechanism disruption in 4 knees. A surgical debridement was performed within 48 hours in 19 of 26 knees. Two-thirds were discharged on antibiotic therapy.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 10 - 10
1 Oct 2020
Bettencourt JW Wyles CC Osmon DR Hanssen AD Berry DJ Abdel MP
Full Access

Introduction

Septic arthritis of the native knee often results in irreversible joint damage leading to the need for a total knee arthroplasty (TKA). This study examines the mid-term risk of periprosthetic joint infection (PJI), aseptic revision, any revision, and any reoperation in primary TKAs after septic arthritis of the native knee compared to a control cohort of primary TKAs performed for osteoarthritis (OA).

Methods

We retrospectively identified 215 primary TKAs performed between 1971 and 2016 at a single institution following septic arthritis of the native knee. Eighty-two percent (177 cases) were treated in a single setting, whereas a two-stage exchange arthroplasty protocol was utilized in 18% (39 cases) for ongoing or suspected active native knee septic arthritis. Each case was matched 1:1 based on age, sex, body mass index (BMI), and surgical year to a primary TKA for OA. Mean age and BMI were 63 years and 30 kg/m2, respectively. Mean follow-up was 9 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 37 - 37
1 Oct 2020
Tibbo ME Limberg AK Gausden EB Huang P Perry KI Yuan BJ Berry DJ Abdel MP
Full Access

Introduction

The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFF). Our study aimed to assess treatment methodologies, implant survivorship, and clinical outcomes of patients with IPFF.

Methods

77 patients treated for an IPFF from 1985–2017 at a single large referral center were reviewed. Prior to the fracture, at the hip/knee sites respectively 46 femurs had primary/primary, 21 had revision/primary, 3 had primary/revision and 7 had revision/revision components. Mean age and BMI were 74 years and 30 kg/m2, respectively. Mean follow-up after fracture treatment was 7 years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 33 - 33
1 Oct 2020
Hamilton WG Loper NR Chen AF Abdel MP Springer BD
Full Access

Background

The COVID-19 pandemic caused an abrupt disruption in fellowship training, with most in-person teaching ceasing in mid-March 2020. An online lecture series was quickly initiated named the Fellows Online COVID-19 AAHKS Learning (FOCAL) initiative. This study will summarize the results of that initiative.

Methods

Beginning March 31, 2020, an online teaching program was initiated. Adult reconstruction fellows and senior residents with interest in adult reconstruction were invited to participate in the free, live, online education sessions. Faculty from well-respected training institutions from around the country volunteered their time to host the initiative, choosing topics to present, ranging from hip (13 lectures) and knee (9), to practice management/miscellaneous (12). All sessions were recorded and posted on the society website for viewing. Attendee registrations were tracked via the online platform and the maximum number of attendees per session was recorded. A survey was administered to attendees for feedback.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 302 - 310
1 Jun 2020
Tibbo ME Limberg AK Salib CG Turner TW McLaury AR Jay AG Bettencourt JW Carter JM Bolon B Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen AJ Abdel MP

Aims

Arthrofibrosis is a relatively common complication after joint injuries and surgery, particularly in the knee. The present study used a previously described and validated rabbit model to assess the biomechanical, histopathological, and molecular effects of the mast cell stabilizer ketotifen on surgically induced knee joint contractures in female rabbits.

Methods

A group of 12 skeletally mature rabbits were randomly divided into two groups. One group received subcutaneous (SQ) saline, and a second group received SQ ketotifen injections. Biomechanical data were collected at eight, ten, 16, and 24 weeks. At the time of necropsy, posterior capsule tissue was collected for histopathological and gene expression analyses (messenger RNA (mRNA) and protein).


Bone & Joint Research
Vol. 8, Issue 12 | Pages 604 - 607
1 Dec 2019
Konan S Abdel MP Haddad FS

There is continued debate as to whether cemented or cementless implants should be utilized in particular cases based upon chronological age. This debate has been rekindled in the UK and other countries by directives mandating certain forms of acetabular and femoral component fixation based exclusively on the chronological age of the patient. This editorial focuses on the literature-based arguments to support the use of cementless total hip arthroplasty (THA), while addressing potential concerns surrounding safety and cost-effectiveness.

Cite this article: Bone Joint Res. 2019;8(12):604–607.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 42 - 42
1 Oct 2019
Vargas-Hernandez JS Berry DJ Abdel MP Sierra RJ
Full Access

Background

Trochanteric fractures account for up to 20% of all periprosthetic fractures occurring during or after total hip arthroplasties (THAs). They are frequently managed conservatively except in cases with significant displacement. There is a paucity of literature describing the indications and results of operative or non-operative management of these fractures.

Methods

173 trochanteric fractures occurred in 171 patients, after all primary THAs performed from 1989–2017. Mean age at fracture was 64-years, with 65% being female. Mean follow-up was 7.6-years. Patient's radiographs and Harris Hip Scores (HHS) were recorded. There were 85 (49%) intraoperative and 88 postoperative fractures. Mean time from THA to fracture was 66 months for the postoperative group. 79 (46%) cases were fixed (68 intraoperative, 11 postoperative). Fixation was considered at the discretion of the surgeon.

Within the 88 postoperative fractures, 30 were associated with polyethylene wear and osteolysis. 77 were initially treated conservatively and 11 were immediately fixed (8 revisions due to osteolysis, and 3 fracture fixations due to disability associated to displacement >1cm). 19 of the 30 postoperative fractures associated with polyethylene wear and osteolysis, eventually underwent revision.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 39 - 39
1 Oct 2019
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI
Full Access

Introduction

While knee arthrodesis is a salvage option for recalcitrant total knee arthroplasty (TKA) periprosthetic joint infection (PJI) it is used relatively uncommonly and contemporary data are limited. We sought to determine the reliability, durability and safety of knee arthrodesis as the definitive treatment for complex, persistently infected TKA in a modern series of patients.

Methods

We retrospectively identified 41 knees treated from 2002–2016 with a deliberate, two-stage knee arthrodesis protocol (TKA resection, high-dose antibiotic spacer, targeted IV antibiotics and followed by subsequent knee arthrodesis) in patients with complex TKA PJI. Mean age was 64 years & mean BMI was 39 kg/m2. Mean follow-up was 4 years. The extensor mechanism was deficient in 66% of knees, and flap coverage was required in 34% of knees. The majority of patients were host grade B (56%) or C (29%), and extremity grade of 3 (71%). Twenty-nine percent had poly-microbial infections, and 49% had multi-drug resistant organisms. Fixation included intramedullary nail (61%), external fixator (24%), and dual plating (15%).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 30 - 30
1 Oct 2019
Bedard NA Cates RA Lewallen DG Hanssen AD Berry DJ Abdel MP
Full Access

Introduction

Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated (as in revision of a failed stemmed implant), the resultant sclerotic canal can impair cemented stem fixation, which is vital for cone ingrowth and long-term fixation. We report the outcomes of our novel solution to this problem, in which impaction grafting and a cemented stem in the diaphysis was combined with an uncemented metaphyseal cone for revision TKAs with severely compromised bone.

Methods

A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems in a novel fashion for 35 revision TKAs. Mean age at revision TKA was 70 years, with 63% being male. Patients had a mean of 4 prior knee arthroplasty procedures. Indications for the revision with this construct were aseptic loosening (80%) and two-stage re-implantation for periprosthetic infection (PJI; 20%). Mean follow-up was 3 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 67 - 67
1 Oct 2019
Statz JM Maly C Carlson SW Abdel MP Hanssen AD Pagnano MW Perry KI
Full Access

Background

Uncemented dual-tapered stems are a popular choice for primary total hip arthroplasty (THA). The purpose of this study was to examine long-term outcomes after primary THA utilizing a single dual-tapered stem.

Patients and Methods

Utilizing our total joint registry, we retrospectively identified 1215 THAs (1055 patients) performed with an uncemented dual-tapered stem from 1998 to 2009. Mean age was 55 years, 70% were male, and mean BMI was 30 kg/m2. Mean follow-up was 10 years. Analysis included implant survivorship, clinical outcomes, and radiographic results.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 73 - 73
1 Oct 2019
Sershon RA Fillingham Y Abdel MP Malkani AL Schwarzkopf R Padgett DE Vail TP Nam D Nahhas CR Culvern C Valle CJD
Full Access

Background

The purpose of this multicenter, randomized clinical trial was to determine the optimal dosing regimen of tranexamic acid (TXA) to minimize perioperative blood loss for revision total hip arthroplasty (THA).

Methods

Six centers prospectively randomized 155 revisions to one of four regimens: 1g of intravenous (IV) TXA prior to incision, a double dose regimen of 1g IV TXA prior to incision and 1g IV TXA during wound closure, a combination of 1g IV TXA prior to incision and 1g intraoperative topical TXA, or three doses of 1950mg oral TXA administered 2 hours preoperatively, 6 hours postoperatively, and on the morning of postoperative day one. Randomization was based upon revision subgroups to ensure equivalent group distribution, including: femur only, acetabulum only, both component, explant/spacer, and second stage reimplantation. Patients undergoing an isolated modular exchange were excluded. An a priori power analysis (alpha = 0.05; beta = 0.80) determined 40 patients per group were required to identify a 1g/dL difference in postoperative hemoglobin reduction between groups. Per-protocol analysis involved an analysis of variance, Fisher's exact tests, and two one-sided t-tests for equivalence.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 34 - 34
1 Oct 2019
Bingham JS Arthur JR Trousdale RT Lewallen DG Berry DJ Abdel MP
Full Access

Introduction

Pelvic discontinuity is a challenging complication. One treatment option that has garnered enthusiasm is acetabular distraction. This method obtains stability via distraction of the discontinuity and placement of an oversized socket (± augments) and elastic recoil of the pelvis. The aims of this study were to report implant survivorship, radiographic results, clinical outcomes, and complications of acetabular distraction for pelvic discontinuity in the largest series to date.

Methods

We retrospectively identified all revision THAs with a Paprosky 3B defect and pelvic discontinuity between 2005 and 2017. Of the 162 patients, 32 were treated with distraction. The mean distraction achieved was 5mm (range, 3–8mm). In addition to distraction with a hemispherical cup, augments were utilized in 3 and cages in 19. The mean age at revision was 68 years with 75% female. Mean follow-up was 3 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 29 - 29
1 Oct 2019
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP
Full Access

Introduction

Metaphyseal fixation during revision total knee arthroplasties (TKAs) is important, but potentially challenging with historical cone designs. Material and manufacturing innovations have improved the size and shape of cones available, and simplified requisite bone preparation. In a very large series, we assessed implant survivorship, radiographic results, and clinical outcomes of new porous 3-D printed titanium metaphyseal cones featuring a reamer-based system.

Methods

We reviewed 142 revision TKAs using 202 cones (134 tibial and 68 femoral) from 2015 to 2016. Sixty cases involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. Mean age was 66 years, with 54 % females. Mean BMI was 34 kg/m2. Patients had a mean of 2.4 prior surgeries and 48% had a history of periprosthetic infection. Mean follow-up was 2 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 35 - 35
1 Oct 2019
Argenson J Ollivier M Sautet P Grisetti Q Abdel MP Parratte S
Full Access

Introduction

Periprosthetic joint infection (PJI) remains the main cause of failure in primary and revision total knee arthroplasties (TKAs). Local delivery of antibiotics, mainly antibiotic-loaded bone cement (ALBC), is commonly employed to prevent PJI. Over the past decade, tantalum and porous titanium have been successfully utilized as metaphyseal fixation devices to address bone loss and improve biologic fixation during revision TKA. However, no study has examined the antimicrobial properties compared to bone cement. The purpose of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement (ALBC) and smooth titanium alloy (STA) to inhibit Staphylococci bacterial agents in an in vitro medium environment, based on the evaluation of the zone of inhibition (ZOI) and the antibacterial activity duration. Our study hypothesis was that we will found no significant difference between groups to inhibit Methicillin-Sensitive or Methicillin-Resistant Staphylococcus aureus (MSSA/MRSA) agents.

Methods

Thirty beads made of 3 different materials (tantalum/ 3D porous titanium/ STA) were bathed during 1hour inside of a solution made of 1g vancomycin with 20-mL of sterile water for injection (bath concentration: 50 mg/mL). Ten 1cm3 cylinders were also created mixing standard surgical cement with 1g of Vancomycin in standardized sterile molds (ALBC beads). Finally, thirty beads made of tantalum/ 3D porous titanium/ STA were bathed in phosphate buffered saline solution to act as a control group. Cylinders were then placed on agar plates inoculated with MSSA and MRSA. Inhibition zone diameters were measured each day and cylinders were transferred onto a new inoculated plate. Inhibition zones were measured with a manual Vernier caliper and with automated software. The mean inhibition zones between groups were compared using the Wilcoxon Test.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2019
Wyles CC Paradise CR Masters TL Patel R Abdel MP Trousdale RT Sierra RJ
Full Access

Introduction

Adverse local tissue reactions (ALTR) can result in devastating soft tissue and osseous destruction, while potentially increasing the risk of concomitant periprosthetic joint infection (PJI). The aims of this study were to evaluate cobalt (Co) and chromium (Cr) levels generated in simulators from metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) constructs, and determine their impact on native tissues and PJI risk through evaluation of human adipose-derived mesenchymal stem cells (AMSCs) and Staphylococcus epidermidis isolates.

Methods

Ten hip simulator constructs were assembled with 36-mm high-offset femoral heads, highly cross-linked polyethylene liners, and titanium stems. Five constructs used CoCr femoral heads and five used ceramic. Constructs were submerged in bovine serum (BS) and run for 1,000,000 cycles. Samples of BS were collected and evaluated for CoCr concentration. Various concentrations of CoCr were chosen for further assessment of cytotoxicity and growth impact on AMSCs and S. epidermidis and compared to inert SiO2.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 64 - 64
1 Oct 2019
Figgie MP Blevins JL Krell EC Chiu Y Stimac JD Heyse TJ Abdel MP
Full Access

Introduction

Primary total knee arthroplasties (TKA) performed in younger patients raise concerns regarding the potential for accelerated polyethylene wear, aseptic loosening, and thus revision TKA at a younger age. The purpose of this study was to determine the long-term implant survivorship, functional outcomes, and pain relief of primary TKA performed in patients under 35 years of age.

Methods

A retrospective review of our institutional registry identified 185 TKAs performed in 119 patients under the age of 35 between 1985 and 2010. Medical records and radiographs were reviewed. Patients were contacted for two serial questionnaires in 2011–2012 and again in 2018. Implant survivorship was calculated using Kaplan-Meier survivorship curves and Cox proportional hazard model. The median age was 26.1 (21.5–30.1) years, with a BMI of 23.5 (20.4–26.6) kg/m2. Median follow-up was 13.9 (8.5–19.8) years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 26 - 26
1 Oct 2019
Taunton MJ Wyles CC Hart A Hevesi M Perry KI Abdel MP Pagnano MW
Full Access

Introduction

There is renewed interest in dislocation after surgical approach with popularization of the direct anterior approach. The purported advantage of both the lateral and direct anterior approaches is decreased risk of dislocation. The purpose of this study was to assess the risk of dislocation by approach following modern primary THA.

Methods

All primary THAs at a single academic institution from 2010 to 2017 were analyzed through our institutional total joint registry. There were 7023 THAs including 3754 posterior, 1732 lateral, and 1537 direct anterior. Risk of dislocation was assessed against the competing risks of revision surgery and death as well as by individual patient and surgical factors including surgical approach. Risk of revision surgery was considered as a secondary outcome. Step-wise selection was utilized to develop multivariable models. Clinical outcomes were documented with the Harris Hip Score (HHS). Mean age was 63 years, 51% were female, and mean body mass index (BMI) was 30 kg/m2. Minimum follow-up was 2 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 35 - 35
1 Oct 2019
Bedard NA Tetreault MW Hanssen AD Lewallen DG Trousdale RT Berry DJ Abdel MP
Full Access

Introduction

Cementation of a new liner into an existing well-fixed acetabular component is common during revision total hip arthroplasties (THAs) for many indications, but most commonly for lack of a modern compatible crosslinked polyethylene liner. However, little is known about the long-term durability of this strategy. The purpose of this study was to evaluate the long-term implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new highly cross-linked polyethylene (HXLPE) liner into a well-fixed acetabular component.

Methods

We retrospectively identified 326 revision THAs where a non-constrained HXLPE liner was cemented into a well-fixed acetabular component. Mean age at revision THA was 63 years, with 50% being female. The most common indications for revision THA were wear and osteolysis (49%), aseptic femoral loosening (35%), and instability (8%). Mean follow-up was 10 years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 36 - 36
1 Oct 2019
Bedard NA Brown TS Lewallen DG Trousdale RT Berry DJ Abdel MP
Full Access

Introduction

Many surgeons are reluctant to use a constrained liner at the time of acetabular component revision given concerns this might result in early acetabular component loosening. We hypothesized that with appropriate initial implant stabilization of highly porous acetabular components with supplemental screw fixation, constrained liners could be safely used at the time of acetabular revision.

Methods

We retrospectively identified 148 revision total hip arthroplasties (THAs) where a constrained liner of one design was cemented into a newly placed highly porous acetabular component fixed with supplemental screws (mean 5 screws). Mean age at revision THA was 69 years, with 68% being female. The most common indications for revision were two-stage re-implantation (33%), recurrent dislocation (30%), and aseptic loosening (22% acetabular; 9% acetabular/femoral component). Mean follow-up was 8 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 67 - 67
1 Oct 2018
Goldman AH Berry DJ Lewallen DG Trousdale RT Sierra RJ Abdel MP
Full Access

Introduction

Historically, the most common indications for re-revision of a total hip arthroplasty (THA) have been aseptic loosening, instability, infection, and peri-prosthetic fracture. As revision implants and techniques have evolved and improved, understanding why contemporary revision THAs fail is important to direct further improvement and innovation. As such, the goals of this study were to determine the implant survivorship of contemporary revision THAs, as well as the most common indications for re-revision.

Methods

We retrospectively reviewed 2568 aseptic revision THAs completed at our academic institution between 2005 and 2015 through our total joint registry. There were 34% isolated acetabular revisions, 18% isolated femoral revisions, 28% both component revisions, and 20% modular component exchanges. The mean age at index revision THA was 66 years, and 46% were males. The most common indications for the index revision THA were aseptic loosening (21% acetabular, 15% femoral, 5% both components), polyethylene wear and osteolysis (18%), instability (13%), fracture (11%), and other (17%). Mean follow-up was 6 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 18 - 18
1 Oct 2018
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP
Full Access

Introduction

Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Methods

Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 17 - 17
1 Oct 2018
Chalmers BP Weston JT Osmon DR Hanssen AD Berry DJ Abdel MP
Full Access

Introduction

There is no literature regarding the risk of a patient developing PJI after primary TKA if the patient has previously experienced PJI of a TKA or THA in another joint. The goal of this study was to compare the risk of PJI of primary TKA in this patient population compared to matched controls.

Methods

We retrospectively reviewed 95 patients (102 primary TKAs) from 2000–2014 with a history of a TKA or THA PJI in another joint. Mean age was 69 years; mean BMI was 36 kg/m2. 27% high-risk patients were on chronic antibiotic suppression. Mean follow-up was 6 years. We 1:3 matched (to age, sex, BMI, and surgical year) these to 306 primary TKAs performed in patients with a THA or TKA of another joint without a subsequent PJI. Competing risk with death was used for statistical analysis. Multivariate analysis was utilized to evaluate risk factors for PJI in the study cohort.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 66 - 66
1 Oct 2018
Vigdorchik JM Novikov D Abdel MP Mercuri J Long WJ Bosco J Schwarzkopf R
Full Access

Introduction

Complications can be defined as preventable, potentially preventable, or non-preventable. While often discussed, there are virtually no data whether or not the most common causes of revision total hip arthroplasty (THA) are preventable or not. The goal of this study was to identify and report preventable causes of revision THA within 5 years of the index THA.

Methods

We conducted a retrospective review of 128 consecutive revision THAs between August 2015 and August 2017, with 62% being referred from another institution. Mean time to revision THA from the index arthroplasty was 10 months. Mean age at revision THA was 61 years, with 67% being female. Three fellowship-trained adult reconstruction surgeons reviewed the radiographs and operative notes and classified the revision THAs into two categories: preventable vs. non-preventable. Reviewers were instructed to be extremely lenient with the benefit of the doubt given to the operative surgeon. Inter-observer reliability was assessed by Cohen's kappa analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 74 - 74
1 Oct 2018
Hines JT Petis SM Amundson AW Sierra RJ Pagnano MW Abdel MP
Full Access

Introduction

Tranexamic acid (TXA) has been shown to significantly reduce transfusion rates in primary total hip arthroplasties (THAs), but data is limited in the revision setting. The purpose of the current study was to compare the rate of blood transfusions and symptomatic venous thromboembolic events (VTEs) in a large cohort of revision THAs treated with or without IV TXA.

Methods

We performed a retrospective review of 3,264 revision THAs (2,645 patients) between 2005–2014, of which 1,142 patients received IV TXA (1g at incision and 1g at closure). The mean age was 65 years with 49% males in the revision group with TXA, and 67 years with 45% males in the revision group treated without TXA. Outcomes analyzed included rates of transfusion and VTE (within 90 days) between cases treated with TXA and cases not treated with TXA. These comparisons were performed for the overall cohort, as well as within the subset of aseptic cases and septic cases. In order to minimize potential bias between these two subgroups, the analyses were weighted with inverse probability of treatment weights based on a propensity score which included age at revision THA, sex, BMI, ASA score, preoperative anticoagulation, and year of surgery. Mean follow-up was 2 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2018
Fillingham YA Darrith B Calkins T Abdel MP Malkani AL Schwarzkopf R Padgett DE Sershon RA Bini S Della Valle CJ
Full Access

Introduction

Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA that is associated with greater blood loss. The purpose of this multi-center randomized trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA.

Methods

233 Septic and aseptic revision TKA from six-centers were randomized to either receive 1g pre-incision intravenous (IV) TXA, 1g pre- and post-incision IV TXA, 1g pre-incision IV and 1g intra-operative topical TXA, or three doses of 1950mg oral TXA given 2 hours pre-operatively, 6 hours post-operatively, and the morning of postoperative day 1. Randomization was performed based on type of revision to ensure equivalent distribution among groups. The primary outcome was reduction in hemoglobin. Power analysis determined 40 patients per group were necessary to identify a 1g/dL difference with an alpha of 0.05 and beta of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence.


Bone & Joint Research
Vol. 6, Issue 3 | Pages 162 - 171
1 Mar 2017
Walker JA Ewald TJ Lewallen E Van Wijnen A Hanssen AD Morrey BF Morrey ME Abdel MP Sanchez-Sotelo J

Objectives

Sustained intra-articular delivery of pharmacological agents is an attractive modality but requires use of a safe carrier that would not induce cartilage damage or fibrosis. Collagen scaffolds are widely available and could be used intra-articularly, but no investigation has looked at the safety of collagen scaffolds within synovial joints. The aim of this study was to determine the safety of collagen scaffold implantation in a validated in vivo animal model of knee arthrofibrosis.

Materials and Methods

A total of 96 rabbits were randomly and equally assigned to four different groups: arthrotomy alone; arthrotomy and collagen scaffold placement; contracture surgery; and contracture surgery and collagen scaffold placement. Animals were killed in equal numbers at 72 hours, two weeks, eight weeks, and 24 weeks. Joint contracture was measured, and cartilage and synovial samples underwent histological analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 60 - 60
1 Jan 2016
Abdel MP Parratte S Budhiparama NC
Full Access

Whether to resurface the patella during a primary Total Knee Replacement (TKR) performed as a treatment of degenerative osteoarthritis remain a controversial issue. Patellar resurfacing was introduced because early implants were not designed to accommodate the native patella in an anatomic fashion during the range of motion. Complications related to patella resurfacing became a primary concern and have been associated with the variable revision rates often report post TKR. Subsequent modifications in implant design have been made to offer the surgeon option of leaving the patella un-resurfaced.

Numerous clinical trials have been done to determine the superiority of each option. Unfortunately, there is little consensus and surgeon preference remains the primary variable. One of the major reasons given to support patella resurfacing is to eliminate Anterior Knee Pain post operatively. However, studies have shown that this problem was not exclusively found in non-resurfaced patients so the author conclude that anterior knee pain is probably related to component design or to the details of the surgical technique, such as component rotation rather that whether or not the patella is resurfaced.

An increasing rate of complications with the extensor mechanism after patellar resurfacing led to the concept of selective resurfacing of the patella in TKR. Decision making algorithms with basis of clinical, radiographic and intraoperative parameters have been developed to determine which patients are suitable for patella resurfacing and which are suitable for patella non-resurfacing.

Finally, the continued study of this topic with longer follow up term in randomized, controlled, clinical trials remains essential in our understanding of patella in TKR. The development of joint registry will allow surgeons to draw conclusions on the basis of larger numbers of patients and will improve the reporting of the results of patellar non resurfacing in clinical trials. In general, surgeons in United States always resurface while their counterparts in Europe tend to never resurface.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 11 - 17
1 Jan 2016
Barlow JD Morrey ME Hartzler RU Arsoy D Riester S van Wijnen AJ Morrey BF Sanchez-Sotelo J Abdel MP

Aims

Animal models have been developed that allow simulation of post-traumatic joint contracture. One such model involves contracture-forming surgery followed by surgical capsular release. This model allows testing of antifibrotic agents, such as rosiglitazone.

Methods

A total of 20 rabbits underwent contracture-forming surgery. Eight weeks later, the animals underwent a surgical capsular release. Ten animals received rosiglitazone (intramuscular initially, then orally). The animals were sacrificed following 16 weeks of free cage mobilisation. The joints were tested biomechanically, and the posterior capsule was assessed histologically and via genetic microarray analysis.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 16 - 19
1 Oct 2015
Oussedik S Abdel MP Cross MB Haddad FS

Many aspects of total knee arthroplasty have changed since its inception. Modern prosthetic design, better fixation techniques, improved polyethylene wear characteristics and rehabilitation, have all contributed to a large change in revision rates. Arthroplasty patients now expect longevity of their prostheses and demand functional improvement to match. This has led to a re-examination of the long-held belief that mechanical alignment is instrumental to a successful outcome and a focus on restoring healthy joint kinematics. A combination of kinematic restoration and uncemented, adaptable fixation may hold the key to future advances.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):16–19.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 82 - 88
1 Mar 2014
Abdel MP Morrey ME Barlow JD Grill DE Kolbert CP An KN Steinmann SP Morrey BF Sanchez-Sotelo J

Objectives

The goal of this study was to determine whether intra-articular administration of the potentially anti-fibrotic agent decorin influences the expression of genes involved in the fibrotic cascade, and ultimately leads to less contracture, in an animal model.

Methods

A total of 18 rabbits underwent an operation on their right knees to form contractures. Six limbs in group 1 received four intra-articular injections of decorin; six limbs in group 2 received four intra-articular injections of bovine serum albumin (BSA) over eight days; six limbs in group 3 received no injections. The contracted limbs of rabbits in group 1 were biomechanically and genetically compared with the contracted limbs of rabbits in groups 2 and 3, with the use of a calibrated joint measuring device and custom microarray, respectively.