header advert
Results 1 - 42 of 42
Results per page:
Bone & Joint Open
Vol. 4, Issue 12 | Pages 932 - 941
6 Dec 2023
Oe K Iida H Otsuki Y Kobayashi F Sogawa S Nakamura T Saito T

Aims

Although there are various pelvic osteotomies for acetabular dysplasia of the hip, shelf operations offer effective and minimally invasive osteotomy. Our study aimed to assess outcomes following modified Spitzy shelf acetabuloplasty.

Methods

Between November 2000 and December 2016, we retrospectively evaluated 144 consecutive hip procedures in 122 patients a minimum of five years after undergoing modified Spitzy shelf acetabuloplasty for acetabular dysplasia including osteoarthritis (OA). Our follow-up rate was 92%. The mean age at time of surgery was 37 years (13 to 58), with a mean follow-up of 11 years (5 to 21). Advanced OA (Tönnis grade ≥ 2) was present preoperatively in 16 hips (11%). The preoperative lateral centre-edge angle ranged from -28° to 25°. Survival was determined by Kaplan-Meier analysis, using conversions to total hip arthroplasty as the endpoint. Risk factors for joint space narrowing less than 2 mm were analyzed using a Cox proportional hazards model.


Bone & Joint Research
Vol. 11, Issue 10 | Pages 715 - 722
10 Oct 2022
Matsuyama Y Nakamura T Yoshida K Hagi T Iino T Asanuma K Sudo A

Aims

Acridine orange (AO) demonstrates several biological activities. When exposed to low doses of X-ray radiation, AO increases the production of reactive radicals (radiodynamic therapy (AO-RDT)). We elucidated the efficacy of AO-RDT in breast and prostate cancer cell lines, which are likely to develop bone metastases.

Methods

We used the mouse osteosarcoma cell line LM8, the human breast cancer cell line MDA-MB-231, and the human prostate cancer cell line PC-3. Cultured cells were exposed to AO and radiation at various concentrations followed by various doses of irradiation. The cell viability was then measured. In vivo, each cell was inoculated subcutaneously into the backs of mice. In the AO-RDT group, AO (1.0 μg) was locally administered subcutaneously around the tumour followed by 5 Gy of irradiation. In the radiation group, 5 Gy of irradiation alone was administered after macroscopic tumour formation. The mice were killed on the 14th day after treatment. The change in tumour volume by AO-RDT was primarily evaluated.


Bone & Joint Research
Vol. 9, Issue 11 | Pages 821 - 826
1 Nov 2020
Hagi T Nakamura T Kita K Iino T Asanuma K Sudo A

Aims

Tocilizumab, an interleukin-6 (IL-6) receptor (IL-6R) targeting antibody, enhances the anti-tumour effect of conventional chemotherapy in preclinical models of cancer. We investigated the anti-tumour effect of tocilizumab in osteosarcoma (OS) cell lines.

Methods

We used the 143B, HOS, and Saos-2 human OS cell lines. We first analyzed the IL-6 gene expression and IL-6Rα protein expression in OS cells using reverse transcription real time quantitative-polymerase chain reaction (RT-qPCR) analysis and western blotting, respectively. We also assessed the effect of tocilizumab on OS cells using proliferation and invasion assay.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 360 - 367
1 Jul 2020
Kawahara S Hara T Sato T Kitade K Shimoto T Nakamura T Mawatari T Higaki H Nakashima Y

Aims

Appropriate acetabular component placement has been proposed for prevention of postoperative dislocation in total hip arthroplasty (THA). Manual placements often cause outliers in spite of attempts to insert the component within the intended safe zone; therefore, some surgeons routinely evaluate intraoperative pelvic radiographs to exclude excessive acetabular component malposition. However, their evaluation is often ambiguous in case of the tilted or rotated pelvic position. The purpose of this study was to develop the computational analysis to digitalize the acetabular component orientation regardless of the pelvic tilt or rotation.

Methods

Intraoperative pelvic radiographs of 50 patients who underwent THA were collected retrospectively. The 3D pelvic bone model and the acetabular component were image-matched to the intraoperative pelvic radiograph. The radiological anteversion (RA) and radiological inclination (RI) of the acetabular component were calculated and those measurement errors from the postoperative CT data were compared relative to those of the 2D measurements. In addition, the intra- and interobserver differences of the image-matching analysis were evaluated.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 87 - 87
1 Feb 2020
Yoshitani J Kabata T Kajino Y Inoue D Ohmori T Taga T Takagi T Ueno T Ueoka K Yamamuro Y Nakamura T Tsuchiya H
Full Access

Aims

Accurate positioning of the acetabular component is essential for achieving the best outcome in total hip arthroplasty (THA). However, the acetabular shape and anatomy in severe hip dysplasia (Crowe type IV hips) is different from that of arthritic hips. Positioning the acetabular component in the acetabulum of Crowe IV hips may be surgically challenging, and the usual surgical landmarks may be absent or difficult to identify. We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component as assessed by morphometric geometrical analysis and its reliability.

Patients and Methods

A total of 52 Crowe IV and 50 normal hips undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiographic inclination of 40° and anteversion of 20° (Figure 1). Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis (Figure 2). To describe major trends in shape variations within the sample, we performed a principal component analysis of partial warp variables (Figure 3).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 47 - 47
1 Mar 2017
Nakamura T Niki Y Nagai K Sassa T Heldreth M
Full Access

Introduction

Design evolution of total knee arthroplasty (TKA) has improved implant durability and clinical outcomes. However, it has been reported that some patients have limited satisfaction with their operated knees [1].

In view of better patient satisfaction, there have been growing interests in anatomically aligned TKA. The anatomically aligned TKA technique aims to replicate natural joint line of the patients [2][3]. However, restoration of natural joint line may be difficult for the knees with severe deformity, as their joint alignment with respect to bony landmarks at a time of surgery may be critically different from their pre-diseased state.

The purpose of this study is to investigate alignment of the tibial growth plate with respect to tibial anatomical landmarks for possible application in estimation of pre-diseased joint alignment.

Methods

Three-dimensional tibial models were created from CT scans of 22 healthy Japanese knees (M7:F15, Age 31.0±12.6 years) using Mimics (Materialise NV, Leuven, Belgium).

The mid-sagittal plane of the tibia was defined by medial margin of the tibial tuberosity, origin of the PCL and center of the foot joint. The tibial plateau (or joint line plane) was determined by following three points; a dwell point of aligned femur on lateral tibial articular surface, and two points at anterior and posterior rim of medial tibial articular surface defined within sagittal plane that coincide with dwell point of femur on medial tibia. All measurements were made with respect to the mid-sagittal plane.

The shape of the tibial growth plate (GP) was extracted using Livewire function and mask editing tools of Mimics. To determine 3D orientation of the GP, moment of inertia axes were calculated for the 3D model. The inertia axes were also determined for medial and lateral half of the GP (Figure 1).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 73 - 73
1 May 2016
Nakamura T Niki Y Nagai K Sassa T Heldreth M
Full Access

Introduction

Kinematically or anatomically aligned total knee arthroplasty (TKA) has been reported to provide improved clinical outcomes by replicating patient's original joint line [1][2].

It has been known that tibial (joint line) varus varies among patients, and the tibial varus would increase over progression of arthritis and bone remodeling. For those patients with significant deformity, the current tibial varus may significantly differ from its pre-diseased state.

In this exploratory study, geometry and alignment of the tibial growth plate were measured with respect to tibial anatomical landmarks in order to better understand modes of tibial deformity and seek possible application in reconstructing pre-diseased joint alignment.

Methods

CT scans of sixteen healthy Japanese knees (M6:F10, Age 31.9±13.9 years) were studied. Three-dimensional reconstruction models were created using Mimics 17 (Materialise, Leuven, Belgium). First, a mid-sagittal tibial reference plane, for comparing the varus/valgus orientation of the tibial plateau to that of the growth plate, was defined by the medial margin of the tibial tuberosity, origin of the PCL and center of the foot joint. The tibial plateau (or joint line plane) was determined from three points; dwell point of femur (aligned in extension) on lateral tibial articular surface, and two points at anterior and posterior rim of medial tibial articular surface sampled in the sagittal view and coinciding with dwell point of femur on medial tibia.

Then, a three-dimensional model of the tibial growth plate was extracted using the Livewire function and mask editing tools in Mimics. To determine 3D orientation of the growth plate (GP), the vertical mass moment of inertia axis was calculated for the 3D model. The inertia axes were also determined for medial and lateral half of the GP (Figure 1).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 150 - 150
1 Jan 2016
Liao Y Whitaker D Nakamura T Hardaker C
Full Access

Introduction

Moderately crosslinked, thermally treated ultrahigh molecular weight polyethylene (UHMWPE) has to date demonstrated a good balance of wear resistance and mechanical properties. MARATHON™ Polyethylene (DePuySynthes Joint Reconstruction, Warsaw, IN) is made from polyethylene resin GUR 1050, gamma-irradiated at a dose of 5.0 Mrads to create crosslinking of polyethylene, and followed by a remelting process to eliminate free radicals for oxidative stability. 10-year clinical study [1] and laboratory wear simulation tests [2–3] have reported excellent wear performance of the MARATHON poly.

There continues to be demand for improved head-to-shell ratio acetabular systems because larger head sizes have the benefits of increased stability and range of motion. The increased head-to-shell ratio is often times achieved by using a reduced liner thickness. One of the clinical concerns of thinner poly liners is the potential for rim fracture, particularly in the occurrences of rim loading or impingement at high cup angles [4–7].

This study investigated the performance of thinner poly liners to the challenge of high angle rim loading and neck-to-liner impingement.

Materials and Methods

Three groups of ETO sterilized MARATHON polyethylene liners (ID/OD: 28/44, 32/48, and 36/52 mm) were paired with matching CoCrMo heads (n=6 each group). To simulate rim loading, liners were assembled in the metal shells tilted at 64° (Figure 1) with sinusoidal loading (0 to 5000N at 3Hz) in a 37°C water bath for 5-million cycles or until component failure, whichever occurred first.

For neck-liner impingement testing, metal shells were potted at 54º (in the abduction/adduction plane with a ±10° of motion per ISO 14242–1 [8]) on a hip simulator (n=4 each group) using a physiological loading (max 3000N at 1Hz) for 3-million cycles (Figure 2). The impingement occurred at 64º during the simulated gait cycle (Figure 3).

The liners were inspected every million cycles, using a high intensity light to search for signs of crack initiation and/or fractures. Both test methods were validated to be able to replicate liner fractures.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 131 - 131
1 Jan 2016
Fitzpatrick CK Clary C Nakamura T Rullkoetter P
Full Access

Introduction

The current standard for alignment in total knee arthroplasty (TKA) is neutral mechanical axis within 3° of varus or valgus deviation [1]. This configuration has been shown to reduce wear and optimally distribute load on the polyethylene insert [2]. Two key factors (patient-specific hip-knee-ankle (HKA) angle and surgical component alignment) influence load distribution, kinematics and soft-tissue strains across the tibiofemoral (TF) joint. Improvements in wear characteristics of TKA materials have facilitated a trend for restoring the anatomic joint line [3]. While anatomic component alignment may aid in restoring more natural kinematics, the influence on joint loads and soft-tissue strains should be evaluated. The purpose of the current study was to determine the effect of varus component alignment in combination with a variety of HKA limb alignments on joint kinematics, loads and soft-tissue strain.

Methods

A dynamic three-dimensional finite element model of the lower limb of a TKA patient was developed. Detailed description of the model has been previously published [4]. The model included femur, tibia and patella bones, TF ligaments, patellar tendon, quadriceps and hamstrings, and was virtually implanted with contemporary cruciate-retaining fixed-bearing TKA components. The model was initially aligned in ideal mechanical alignment with neutral HKA limb alignment. A design-of-experiments (DOE) study was performed whereby component placement was altered from neutral to 3° and 7° varus alignment, and HKA angle was altered from neutral to ±3° and ±7° (valgus and varus) (Figure 1).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 98 - 98
1 Jan 2016
Kawamura H Oe K Ueda Y Okamoto N Nakamura T Ueda N Iida H
Full Access

Introduction

Highly cross-linked polyethylene (HXLPE) was developed to reduce the wear of articular-bearing surfaces in total hip arthroplasty (THA). This study aimed to compare the mean linear wear of HXLPE with a 22.225 mm diameter zirconia head with that of conventional polyethylene (CPE) with a 22.225 mm diameter ortron head.

Materials and Methods

A prospective cohort study performed on 93 patients (113 hips) who had undergone primary cemented THAs at our hospital between January 2001 and December 2003. The subject population included 85 females and 8 males with a mean age of 58.0 years (22 to 78) at the time of surgery. The mean follow-up period was 10.2 years (9 to 12). We randomly used two types of implants: the HXLPE cup with a 22.225 mm diameter zirconia head (Kyocera Medical, Osaka, Japan) in 60 hips (HXLPE group), and the CPE cup with a 22.225 mm diameter ortron head (DePuy International, Leeds, UK) in 53 hips (CPE group). Linear wear (penatration) by computer-assisted method with PolyWare software (Draftware Inc, Indiana, USA) was measured at 10 years. Anteroposterior radiographs were evaluated for osteolysis or component loosening defined by the criteria of Hodgkinson et al. Analysis of covariance using the general linear models procedure was carried out to determine the linear wear rate difference between the groups after adjusting for variables (age at surgery, sex, body mass index, vertical distance, horizontal distance, cup inclination, and cup anteversion) as covariates. The differences were considered significant when the p value was <0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 96 - 96
1 Jan 2016
Oe K Ueda N Nakamura T Okamoto N Ueda Y Iida H
Full Access

Introduction

Antibiotic-loaded acrylic cement (ALAC) is employed in the treatment or prevention of infected total hip arthroplasty (THA). We have administered vancomycin (VCM) as the ALAC for the treatment of THAs with methicillin-resistant Staphylococcus aureus, or for the prevention of THAs with high risks. This study aimed to evaluate the serum concentration of VCM from ALAC in THA or cement beads.

Methods

Between December 2013 and February 2014, 16 hips (16 patients) underwent application of the ALAC including VCM at our institution. Two hips were used for the treatment of infection, in the first stage of two-staged revision THAs (i.e., cement beads). Two hips were used for the both treatment and prevention of infection, in one-staged revision THAs. Twelve hips were used for the prevention of infection, in aseptic revision THAs or primary THAs with high risks. Patients were classified into two groups depending on the VCM concentration of ALAC, as follows: high-dose group (2 hips), average 4.4% (3.8–5.0%); low-dose group (14 hips), average 1.6% (1.3–2.5%). The amount of VCM placed as ALAC into the hip was calculated by using the remaining ALAC. The serum concentration of VCM was evaluated at 1 day, 4 days, 7 days, and 28 days after surgery. Statistical analysis was performed by using the t-test, and the differences were considered significant when the p value was <0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 132 - 132
1 Jan 2016
Fitzpatrick CK Nakamura T Niki Y Rullkoetter P
Full Access

Introduction

A large number of total knee arthroplasty (TKA) patients, particularly in Japan, India and the Middle East, exhibit anatomy with substantial proximal tibial torsion. Alignment of the tibial components with the standard anterior-posterior (A-P) axis of the tibia can result in excessive external rotation of the tibial components with respect to femoral component alignment. This in turn influences patellofemoral (PF) mechanics and forces required by the extensor mechanism. The purpose of the current study was to determine if a rotating-platform (RP) TKA design with an anatomic patellar component reduced compromise to the patellar tendon, quadriceps muscles and PF mechanics when compared to a fixed-bearing (FB) design with a standard dome-shaped patellar component.

Methods

A dynamic three-dimensional finite element model of the knee joint was developed and used to simulate a deep knee bend in a patient with excessive external tibial torsion (Figure 1). Detailed description of the model has been previously published [1]. The model included femur, tibia and patellar bones, TKA components, patellar ligament, quadriceps muscles, PF ligaments, and nine primary ligaments spanning the TF joint. The model was virtually implanted with two contemporary TKA designs; a FB design with domed patella, and a RP design with anatomic patella. The FB design was implanted in two different alignment conditions; alignment to the tibial A-P axis, and optimal alignment for bone coverage. Four different loading conditions (varying internal-external (I-E) torque and A-P force) were applied to the model to simulate physiological loads during a deep knee bend. Quadriceps muscle force, patellar tendon force, and PF and TF joint forces were compared between designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 120 - 120
1 Jan 2016
Watanabe T Muneta T Sekiya I Koga H Horie M Nakamura T Otabe K Banks S
Full Access

INTRODUCTION

Total knee arthroplasty (TKA) is one of the most successful and beneficial treatments for osteoarthritic knees. We have developed posterior-stabilized (PS) total knee prosthesis for Asian patients, especially Japanese patients, and have used it since November, 2010. The component was designed based on the CT images of osteoarthritic knees, aiming to achieve deep flexion and stability. The purpose of this study was to analyze in- vivo kinematics of this new prosthesis.

METHODS

We analyzed a total of 28 knees implanted with PS TKAs: Fourteen knees with the new PS prosthesis (group A), and the other fourteen knees with a popular PS prosthesis as a control group (group B). Preoperative data of both groups were not significantly difference. Flat-panel radiographic knee images were recorded during five static knee postures including full extension standing, lunge at 90° and maximum flexion, and kneeling at 90° and maximum flexion. The three-dimensional position and orientation of the implant components were determined using model-based shape matching techniques. The results of this shape-matching process have standard errors of approximately 0.5° to 1.0° for rotations and 0.5 to 1.0 mm for translations in the sagittal plane. Unpaired t-tests were used for statistical analysis and probability values less than 0.05 were considered significant.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 209 - 209
1 Jul 2014
Ishikawa M Ito H Yoshitomi H Murata K Shibuya H Furu M Kitaori T Nakamura T Matsuda S
Full Access

Summary Statement

MCP-1/ CCR2 axis at the early phase plays a pivotal role in the fracture healing. Inflammation plays a pivotal role in fracture healing. Among them, chemokines play key roles in inflammation. Monocyte chemotactic protein-1 (MCP-1), via its receptor C-C chemokine receptor 2 (CCR2), acts as a potent chemoattractant for various cells to promote migration from circulation to inflammation site. Thus, the importance of MCP-1/CCR2 axis in fracture healing has been suggested. However, the involvement of MCP-1/CCR2 axis tofracture site is not fully elucidated.

Results

PCR Array: The expression of MCP-1 and MCP-3 had increased on day 2 than 0 or 7 in the rib fracture healing. Immunohistochemistry Staining: To verify the localization of MCP-1 expression, we examined the Wild type (WT)-mouse rib fracture healing. We observed high expression of MCP-1 and MCP-3 at the periosteum and the endosteum on post-fracture day 3. In vivo Antagonist Study: To elucidate whether MCP-1/CCR2 axis is involved during the early phase of fracture healing, we continuously administered RS102895, CCR2 antagonist, before or after rib fracture. Micro-CT analysis showed delayed fracture healing in the before-group compared with both the control and after-group. On day 21, the hard callus volume in the before-group was significantly smaller than that in the control-group. Histological analysis showed that fractures in both the control and the after-groups were healed by day 21. In contrast, less of cartilage in the callus was observed in the before-group on day 7. Gain of Function: To examine the roles of MCP-1 at the periosteum and the endosteum during the fracture healing, we created a segmental bone graft exchanging model. The bone grafts were transplanted from MCP-1−/− mice to another MCP-1−/− mice (KO-to-KO). Micro-CT analysis showed that KO-to-KO transplantation led to the delay of fracture healing on day 21. Next, we created exchanging-bone graft models between MCP-1−/− and WT mice, in which a segmental bone derived from a WT mouse was transplanted into a host MCP-1−/− mouse (WT-to-KO). In contrast to KO-to-KO bone graft transplantation, the transplantation of WT-derived graft into host KO mouse resulted in a significant increase of new bone formation on day 21. Histological analysis revealed that marked and localised induction of MCP-1 expression in the periosteum and the endosteum around the WT-derived graft was observed in the host MCP-1−/− mouse. Loss of Function: To validate whether MCP-1 is a crucial chemokine for fracture healing, we created WT-to-WT and KO-to-WT bone graft models. When WT-donor graft was transplanted into WT-host, abundant new bone formation was observed around a WT-derived graft on day 21. In contrast, transplantation of KO-derived graft into WT-host resulted in a marked reduction of periosteal bone formation on a donor graft.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 352 - 352
1 Jul 2014
Oki S Matsumura N Morioka T Ikegami H Kiriyama Y Nakamura T Toyama Y Nagura T
Full Access

Summary Statement

We measured scapulothoracic motions during humeral abduction with different humeral rotations in healthy subjects and whole cadaver models and clarified that humeral rotation significantly influenced scapular kinematics.

Introduction

Scapular dyskinesis has been observed in various shoulder disorders such as impingement syndrome or rotator cuff tears. However, the relationship between scapular kinematics and humeral positions remains unclear. We hypothesised that humeral rotation would influence scapular motions during humeral abduction and measured scapular motion relative to the thorax in the healthy subjects and whole cadavers.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 565 - 565
1 Dec 2013
Ueda N Oe K Kawamura H Nakamura T Okamoto N Ueda Y Iida H
Full Access

Introduction:

The diagnosis of implant-associated infections is challenging, and the conventional culturing of periprosthetic tissue has been the gold standard for diagnosis of implant-associated infections. However, conventional diagnostic tests are inaccurate because the pathogenesis of implant-associated infection is related to microorganisms growing in biofilms. We compared culture of samples obtained by sonication of explanted implants to dislodge adherent bacteria from implants with conventional culture of periprosthetic tissue. The purpose of this study is to evaluate the results of sonication that is microbiological diagnostic method for implant-associated infections.

Materials and Methods:

Between January 2013 and April 2013, a total of 19 consecutive patients underwent the removal of implants at our institution. There were 15 women and 4 men with a mean age of 71 years (32 to 90) at the time of the operation. Implants were removed because of aseptic loosening in 9 patients, infection in 6 patients, necrosis in 2 patients, dislocation in 1 patient and implant fracture in 1 patient. Removed implants, including 17 joint prostheses and 2 fracture fixation devices, were subjected to sonication in a BactoSonic (BANDELIN, Germany). Preoperative bacterial culture, intraoperative conventional culture of periprosthetic tissue, intraoperative culture of sonicate-fluid, and pathological examination were assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 586 - 586
1 Dec 2013
Whitaker D Liao Y Nakamura T Hardaker C
Full Access

Introduction:

Moderately crosslinked polyethylene maintains a balance of wear resistance and mechanical properties. The GVF poly was manufactured from GUR1020 UHMWPE bars, sealed in vacuumed foil package, and gamma sterilized at 4 Mrads. The MARATHON® polyethylene inserts were manufactured from GUR1050 UHMWPE bars, crosslinked by gamma irradiation at 5 Mrad, and followed by a remelting process that eliminates free radicals. The final sterilization method is gas plasma (GP) or ethylene oxide (EtO). Both methods will not introduce free radicals. Previous studies have shown MARATHON polyethylene (GP sterilized) with 83% lower wear than conventional polyethylene in a simulation test [1], compared to a 10-year clinical study that showed 77% wear reduction [2]. There is no study to compare the wear performance of MARATHON (EtO sterilized) and conventional poly.

Materials and Methods:

Four groups of polyethylene inserts (Table 1) were paired with matching femoral heads that were manufactured from CoCrMo (ASTM F1537) with diameters of 28, 32, and 36 mm. The inserts were chosen to have similar thickness at the dome for MARATHON, while for GVF it was the largest head size available.

Wear testing was performed on an AMTI Hip Simulator per the ISO 14242-1 standard [3] at 1 Hz using the described inputs (Table 2), which provide a larger range of motion than the ISO standard. The cups were mounted in accordance with ISO 14242-1 using custom fixturing and secured with cement while the femoral heads were mounted on a vertical taper support. Testing was performed in 25% bovine calf serum at 37 ± 2°C. Wear of the inserts was determined gravimetrically. Finally, wear rates were calculated by linear regression and then compared between the groups using ANOVA analysis (α = 0.05).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 96 - 96
1 Aug 2013
Enomoto H Nakamura T Shimosawa H Niki Y Kiriyama Y Nagura T Toyama Y Suda Y
Full Access

Although proximal tibia vara is physiologically and pathologically observed, it is difficult to measure the varus angle accurately and reproducibly due to inaccuracy of the radiograph because of rotational and/or torsional deformities. Since tibial coronal alignment in TKA gives influence on implant longevity, intra- or extra-medurally cutting guide should be set carefully especially in cases with severe tibia vara. In this context, we measured the proximal tibial varus angle by introducing 3D-coordinate system.

Materials & Methods

Three-dimensional models of 32 tibiae (23 females, 9 males, 71.2 ± 7.8 y/o) were reconstructed from CT data of the patients undergoing CT-based navigation assisted TKA. Clinically relevant mid-sagittal plane is defined by proximal tibial antero-posterior axis and an apex of the tibial plafond. After the cross-sectional contours of the tibial canal were extracted, least-square lines were fitted to define the proximal diaphyseal and the metaphyseal anatomical axis. The proximal tibia vara was firstly investigated in terms of distribution of proximal anatomical axis exits at the joint surface. TVA1 and TVA2 were defined to be a project angle on the coronal plane between the metaphyseal tibial anatomical axis and the proximal diaphyseal anatomical axis, and that between the metaphyseal tibial anatomical axis and the tibial functional axis, respectively. The correlations of each angle with age and femoro-tibial angle (FTA) were also examined.

Results

The proximal anatomical axis exits distributed 4.3 ± 1.7 mm medially and 17.1 ± 3.4 mm anteriorly. TVA1 and TVA2 were 12.5 ± 4.5°(4.4?23.0°) and 11.8 ± 4.4° (4.4?22.0°), respectively. The correlations of FTA with TVA1 (r=0.374, p<0.05) and TVA2 (r=0.439, p<0.05) were statistically significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 67 - 67
1 Apr 2013
Ikeda S Sakai A Tanaka H Takeuchi Y Ohnishi H Murakami H Saito M Ito M Nakamura T
Full Access

Introduction

Atypical femoral fracture focused on relation of bisphosphonate use, frequently. However, the mechanism of atypical femoral fracture was not yet clarified. Atypical femoral fractures have been kept femoral shaft cortical thickness and BMD, practically. We hypothesized that atypical femoral fractures were associated with impaired bone quality and curvature of femoral shaft.

Materials & Methods

We experienced four atypical femoral fractures. One was subtrochanteric and three were shaft fracture. Two cases received bisphosphonate therapy for 3–5 years. BMD, bone metabolic markers, and bone quality markers were evaluated. Histomorphometry and collagen cross-link analysis were performed. Curvature of femoral shaft and 3-D finite element analysis in one incomplete fracture case were assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 45 - 45
1 Apr 2013
Zenke Y Sakai A Oshige T Menuki K Murai T Yamanaka Y Furukawa K Nakamura T
Full Access

The previous bioabsorbable plates have had several issues with regard to clinical usage for fractures. The aims of this study were to demonstrate the clinical results of novel bioabsorbable plates made of hydroxyapatite/poly-L-lactide and titanium plates for metacarpal fractures and to compare mechanical properties of them in a fracture model. The subjects were 33 metacarpal diaphyseal fractures of 27 consecutive patients treated with bioabsorbable plates. The mean age was 35.8 (17–78), 22 male and 5 female was included. The mean follow up period was 7.4months (2–14). All cases achieved bone union, and there were no complication especially for aseptic swelling etc.

Furthermore, we compared the mechanical properties of bioabsorbable and titanium plates. There were no significant differences in 6 month postoperative clinical results including total range of active motion and % of the contralateral grip strength between patients receiving bioabsorbable and titanium plates. The bending strength and stiffness of one-third tubular bioabsorbable plate constructs were comparable with those of titanium plates for 1.5mm screws, and those of semi-tubular bioabsorbable plates were comparable with those of titanium plates for 2.0mm screws. The torsional strength of semi-tubular bioabsorbable plates was significantly greater than that of titanium plates for 2.0mm screws.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 288 - 288
1 Mar 2013
Oe K Okamoto N Asada T Nakamura T Wada T Iida H
Full Access

Introduction

It is still controversial whether one or two-stage revision should be indicated for deeply infected hip prosthesis, and there are no scoring systems for the decision of them. An assessment system for the treatment of deeply infected hip prosthesis was evaluated for the patients who had undergone one or two-stage revision total hip arthroplasty (THA).

Materials and Methods

Between February 2001 and November 2009, revision THA for deep infection was carried out in 60 hips on 59 patients by the senior authors. Nineteen hips underwent one-stage revision THA using antibiotic-loaded acrylic cement (ALAC), and 41 hips did two-stage revision THA using ALAC beads, based on the criteria by Jackson and Schmalzried. This study included 47 revisions in 47 patients for which a minimum follow-up of two years (average 4.7 years). Six parameters were employed in the assessment system: 1) general condition, 2) duration of infection, 3) wound complication after initial operation, 4) microorganism, 5) C-reactive protein (CRP), and 6) necessity for grafting bone. Each parameter ranged from 0 to 2 points, giving a full score of 12 points. Healing was defined as the lack of clinical signs and symptoms of infection, a CRP level < 10 mg/l or an erythrocyte sedimentation rate < 20 mm/h, and the absence or radiological signs of infection at the follow-up visit > 24 months after first revision, described by Giulieri et al.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 28 - 28
1 Oct 2012
Takemoto M Neo M Fujibayashi S Okamoto T Ota E Sakamoto T Nakamura T
Full Access

The accuracy of pedicle screw placement is essential for successful spinal reconstructive surgery. The authors of several previous studies have described the use of image-based navigational templates for pedicle screw placement. These are designed based on a pre-operative computed tomographic (CT) image that fits into a unique position on an individual's bone, and holes are carefully designed to guide the drill or the pedicle probe through a pre-planned trajectory. The current study was conducted to optimise navigational template design and establish its designing method for safe and accurate pedicle screw placement.

Thin-section CT scans were obtained from 10 spine surgery patients including 7 patients with adolescent idiopathic scoliosis (AIS) and three with thoracic ossification of the posterior longitudinal ligament (OPLL). The CT image data were transferred to the commercially available image-processing software and were used to reconstruct a three-dimensional (3D) model of the bony structures and plan pedicle screw placement. These data were transferred to the 3D-CAD software for the design of the template. Care was taken in designing the template so that the best intraoperative handling would be achieved by choosing several round contact surfaces on the visualised posterior vertebral bony structure, such as transverse process, spinous process and lamina. These contact surfaces and holes to guide the drill or the pedicle probe were then connected by a curved pipe. STL format files for the bony models with planned pedicle screw holes and individual templates were prepared for rapid prototype fabrication of the physical models. The bony models were made using gypsum-based 3D printer and individual templates were fabricated by a selective laser melting machine using commercially pure titanium powder. Pedicle screw trajectory of the bony model, adaptation and stability of the template on the bony model, and screw hole orientation of the template were evaluated using physical models. Custom-made titanium templates with adequate adaptation and stability in addition to proper orientation of the screw holes were sterilised by autoclave and evaluated during surgery.

During segmentation, reproducibility of transverse and spinous processes were inferior to the lamina and considered inadequate to select as contact surfaces. A template design with more bone contact area might enhance the stability of the template on the bone but it is susceptible to intervening soft tissue and geometric inaccuracy of the template. In the bony model evaluation, the stability and adaptation of the templates were sufficient with few small round contact surfaces on each lamina; thus, a large contact surface was not necessary. In clinical patients, proper fit for positioning the template was easily found manually during the operation and 141/142 screws were inserted accurately with 1 insignificant pedicle wall breach in AIS patient.

This study provides a useful design concept for the development and introduction of custom-fit navigational template for placing pedicle screws easily and safely.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 67 - 67
1 Oct 2012
Enomoto H Nakamura T Shimosawa H Waseda A Niki Y Toyama Y Suda Y
Full Access

Although optimal alignment is essential for improved function and implant longevity after TKA, we have less bony landmarks of tibia relative to femur. Trans-malleolar axis (TMA) is a reference line of distal tibia in the axial plane, which externally rotated relative to a ML axis of proximal tibia. We originally defined another reference axis associated with the orientation of tibial plafond, and then measured tibial torsion in the 3D-coordinate system.

Three-dimensional CAD models of 20 tibiae were reconstructed based on pre-operative CT data from OA patients (16 females and 4 males, 73.8 ± 6.9 years old). TMA was a line connecting each apex of medial and lateral malleolus. The plafond axis (PLA) that we originally defined in this study was a line connecting each midpoint of medial and lateral margin of talocrural facet. In terms of interobserver correlation coefficiency and mean errors of the designated points to define those axes, TMA was found out to be 0.982, 3.14 ± 0.47 mm (medial), and 0.988, 4.88 ± 0.59 mm (lateral). Those of PLA were 0.997, 1.97 ± 0.53 mm (medial), and 0.995, 2.02 ± 0.44 mm (lateral). The tibial torsion was 16.3 ± 6.3°with reference to TMA, and 10.2 ± 8.4°to PLA.

Based on these results, as for the rotational reference axis in the axial plain of distal tibia, we consider the plafond axis to be another reliable and reproducible axis, which is expected to be applicable in preoperative planning in TKA to reduce outliers of coronal alignment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 119 - 119
1 Sep 2012
Nakamura T
Full Access

It is very important to fix implant to bone. Bioactive materials as hydroxyapatite or glass-ceramics have bone-bonding ability. Hydroxyapatite-coating is applied to cementless THA or TKA. I and coworkers investigated bone-bonding mechanism of bioactive material and found that bone-like apatite formation play key role for bonding. If the surface of metal is changed to form apatite on it in body, the inert metal changes into bone-bonding material. We developed alkaline and heat treatment of titanium to change titanium to bone –bonding material as follows. At first, titanium is dipped in 5N NaOH solution for 24 hours, at second the metal is washed in pure water and finally it is sintered in 500 degree C for 2 hours. The treated surface has bioactivity, bone bonding ability like hydroxyapatite. The advantage of this treatment over hydroxyapatite-coating procedure is to treat the porous surface without any change of pore figures. As to hydroxyapatite-coating procedure, pore of the small diameter is filled with hydroxyapatite and pore figures are change. We applied this alkaline and heat treatment to cementless THA and its good results of more than ten years was reported.

Porous titanium can be changed to bioactive material by alkaline and heat treatment. This bioactive porous titanium was found to have a property of material-induced osteoinduction, that is, the bone formation in pore of porous titanium implanted in canine back muscle. They can be used for bone substitute for big bone defect. We used two procedures to make porous titanium, sintering of titanium powder with spacer particle of ammonium sulfate and selective lazar melting. The latter procedure can produce any type of pore structure of titanium. Selective laser melting was employed to fabricate porous Ti implants (diameter 3.3 mm, length 15 mm) with a channel structure comprising four longitudinal square channels, representing pores, of different diagonal widths, 500, 600, 900, and 1200 micrometer. These were then subjected to chemical and heat treatments to induce bioactivity. Significant osteoinduction was observed in widths 500 and 600 micrometer, with the highest observed osteoinduction occurring at 5 mm from the end of the implants. A distance of 5 mm probably provides a favorable balance between blood circulation and fluid movement.

New bioactive bone cement is another topic of the application of bioactive titanium in this lecture. The bone cement contains barium sulphate for radiocontrast. We developed a procedure to replace barium sulphate with bioactive titanium powder. This new bone cement has not only better biocompatibility than conventional cement but also bone bonding ability. It is potent material for the fixation of implant to bone. I will speak the evaluation of this cement using canine model of THA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 118 - 118
1 Sep 2012
Nakamura S Nakamura T Kobayashi M Ito H Ikeda N Nakamura K Komistek R
Full Access

Introduction

Achieving high flexion after total knee arthroplasty is very important for patients in Asian countries where deep flexion activities are an important part of daily life. The Bi-Surface Total Knee System (Japan Medical Material, Kyoto, Japan), which has a unique ball-and-socket mechanism in the mid-posterior portion of the femoral and tibial components, was designed to improve deep knee flexion and long-term durability after total knee arthroplasty (Figure 1). The purpose of this study was to determine the in vivo three dimensional kinematics of Bi-Surface Total Knee System in order to evaluate and analyze the performance of this system with other conventional TKA designs currently available in the market today.

Materials and Methods

Three dimensional kinematics were evaluated during a weight-bearing deep knee bend activity using fluoroscopy and a 2D-to-3D registration technique for 66 TKA. Each knee was analyzed to determine femorotibial kinematics, including weight-bearing range of motion, anterior/posterior contact position, and tibio-femoral rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 227 - 227
1 Jun 2012
Suguro T Yamamoto K Miyazaki Y Nakamura T Sekiguchi M Banks S
Full Access

Aims

Recently, total knee arthroplasty (TKA) has been generalized as an operation that achieves excellent clinical results. However, younger and Asian patients require even greater implant longevity and functional performance. We hypothesized a novel posterior cruciate-retaining TKA design that restores the anatomical jointline in both sagittal and coronal planes, maintains the femoral posterior condylar offset, and provides low contact stress would provide enhanced patient function with the potential for greater implant longevity.

Methods

The novel TKA design was created based on geometry determined from anatomic specimens, 3-degree step of femorotibial jointline was incorporated in the TKA design for Asian. The novel TKA has an asymmetrical design between the medial and lateral femoral condyle, the medial femoral condyle designed to be 3 degrees larger than the lateral femoral condyle. It refined using finite element analyses (FEA) to minimize peak contact stresses. The alignment evaluation after TKA was performed using using bidirectional CR and CT images. Femorotibial-angle (FTA), the position of the femoral component relative to the 3D mechanical axis, and the rotational alignment of the femoral component relative to the PC line were evaluated before and after TKA to identify changes in the femoral condylar shape. The kinematic evaluation after TKA was performed using a 3D-to-2D model registration technique. Single-plane fluoroscopic imaging was used to record and quantify the motions of knees during a stair-step activity. The contact points between the tibiofemoral motions and the tibial rotational angle were evaluated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 77 - 77
1 Jun 2012
Goto K Akiyama H Kawanabe K So K Nakamura T
Full Access

One cementless cup which had porous outer surface with Apatite-Wollastonite glass ceramic (AWGC) coating, was revised 13 years after primary THA because of massive osteolysis expanded to medial iliac wall along the screws. While many retrieved studies of hydroxyapatite-coated cup have been reported, there has been no report on the retrieved cup with AWGC coating. The purpose of this study was to describe this rare case in detail, confirm the bone ingrowth to the porous cup, and discuss on the effectiveness of porous surface with AWGC coating.

Case

The patient was a 64 old woman and complained of chronic mild pain around her left groin region. X-ray examination revealed that osteolysis had been expanding around the screws and extended proximally. The revision surgery was performed for the massive osteolysis through Hardinge antero-lateral approach. The retrieved implants included a cementless cup made of titanium alloy (QPOC cup, Japan Medical Materirals Inc.(JMM) Osaka, Japan), the outer surface of which was plasma-sprayed with titanium for porous formation and coated with AWGC in the deep layer. It was found that the polyethylene liner was destructed partially in the supero-lateral portion, but the cup was well fixed to the bone. The bone-attached area was found to be dispersed over the porous surface of the hemispherical cup. Histological examination revealed that matured bony tissue intruded into the porous surface of the cup, and contacted to bone directly, which was also demonstrated in the back-scattered electron image. It was also demonstrated that there were residual silicon (Si) rich regions on the porous surface by the SEM-EDX analysis, which indicated that constituents of AWGC still remained on the surface. On the other hand, the results of elementary analyses in the Si rich regions varied among the sections, which probably indicated that the extent of degradation and absorption of AWGC varied among the sections.

AWGC was one of the bioactive ceramics and reported to have an ability to bond to bone earlier than hydroxyapatite (HA). In the present case, though massive osteolysis occurred with aggressive wear, it did not expand on the porous surface, and rather progressed along the smooth surface of the screws. Considering that there are many clinical studies reporting poor clinical results of HA-coated smooth cups, bioactive ceramic coating may function well and bring superior clinical results when combined with porous coated substrate. In our study, though the cause of massive polyethylene wear and intrapelvic giant osteolysis could not be revealed, the porous cup with AW-GC bottom coating was well fixed and gained bone-ingrowth at the porous surface under osteolytic conditions, which may demonstrate the long-term durability of this surface treatment.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 432 - 432
1 Nov 2011
Enomoto H Nakamura T Yanagimoto S Kaneko H Fujita Y Funayama A Suda Y Toyama Y
Full Access

In the light of the increasing popularity of femoral resurfacing implants, there has been growing concern regarding femoral neck fracture. This paper presents a detailed investigation of femoral neck anatomy, the knowledge of which is essential to optimise the surgical outcome of hip resurfacing as well as short hip stem implantation.

Three-dimensional lower limb models were reconstructed from the CT-scan data by using the Mimics (Materialise NV, Leuven, Belgium). We included the CT data for 22 females and nine males with average age of 60.7 years [standard deviation: 16.4]. A local coordinate system based on anatomical landmarks was defined and the measurements were made on the unaffected side of the models.

First, the centre of the femoral head was identified by fitting an optimal sphere to the femoral head surface. Then, two reference points, one each on the superior and the inferior surface of the base of femoral neck were marked to define the neck resection line, to which an initial temporary neck axis was set perpendicular. Cross-sectional contours of the cancellous/cortical border were defined along the initial neck axis. For each cross-sectional contour, a least-square fitted ellipse was determined. The line that connects the centre of the ellipse at the base of the femoral neck and the centre of the femoral head was defined as the new neck axis. The above process was repeated to reduce variances in the estimation of the initial neck axis. The neck isthmus was identified according to the axial distributions of the cross-sectional ellipse parameters.

The short axis of the ellipse decreased monotonically since it was calculated from the center of the femoral head to the neck resection level (base of neck), whereas the long axis changed with the local minima. The cross section at which the long axis of the fitted ellipse had the local minima was determined as the neck isthmus.

The following measurements were made on the proximal part of the femur. The neck axis length measured from the center of the femoral head to the lateral endosteal border of the proximal femur was 67.3 mm [6.4]. The length between the center of the femoral head and the neck isthmus was 22.5 mm [2.7]. The diameter of the ellipse long axis at the neck isthmus was 27.6 mm [3.5] and was 23.6 mm [3.3] for the short axis.

The center of the neck isthmus did not align with the neck axis. The deviation of the isthmus from the neck axis which we defined as the isthmus offset was 0.7 mm [0.4].

If an alternative neck axis was defined between the center of the femoral head and the center of the neck isthmus, there would be a certain degree of angular shift with respect to the original neck axis. An angular shift of 1.8 degrees between the two axes can be expected for a 0.7-mm isthmus offset. In the worst case, an angular shift of 4.59 degrees was estimated for a subject with the largest isthmus offset of 1.93 mm.

Further investigations would be necessary to determine the axis configuration that represents the clinically relevant centre of the femoral neck. In order to reduce the deviations in the three-dimensional determination of the femoral neck axis, the reference anatomical landmarks and methods of evaluation should be carefully selected.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 405 - 405
1 Nov 2011
Nakamura S Kobayashi M Ito H Yoshitomi H Arai R Nakamura K Ueo T Nakamura T
Full Access

In Far East, including Japan and the Middle East, daily activities are frequently carried out on the floor. Deep flexion of the knee joint is therefore very important in these societies. Some patients who underwent total knee arthroplasty (TKA) in these countries often perform deep flexion activity, such as squatting, cross-leg sitting and kneeling. However it is still unknown that deep flexion activity affects long term durability after TKA. The purpose of this study was to examine the correlation between deep flexion and long term durability.

Between December 1989 and May 1997, 507 total knee arthroplasties were carried out in 371 patients using the Bi-Surface Knee System (Japan Medical Material, Osaka, Japan) at two institutions and routine rehabilitation program continued for one to two months after TKA. One patient who underwent simultaneous bilateral TKA was excluded because of pulmonary embolism within one month. The other 505 knees (370 patients) were divided into two groups according to the range of flexion after our routine rehabilitation program; one group (Group A: 207 knees) consisted of more than 135 degrees flexion knees and the other group (Group B: 298 knees) consists of less than 135 degrees flexion knees. Patients whose follow-up period was less than 10 years were excluded from this clinical evaluation. Range of flexion was measured preoperatively, at the time after routine rehabilitation program, and at the latest follow-up. Knee function was evaluated on the basis of Knee Society knee score and functional score preoperatively and at the latest follow-up. Kaplan-Meier survivorship analysis was performed with revision for any operation as the end point.

In Group A, the mean preoperative range of flexion was 133.0±16.3 degrees, and at the time after routine rehabilitation program, this improved to 139.7±5.1 degrees. This angle maintained to 136.2±14.3 at the latest follow-up. In Group B, the mean preoperative range of flexion was 111.6±20.4 degrees, and at the time after routine rehabilitation program, this improved to 114.5±13.6 degrees. This angle maintained to 118.2±17.8 at the latest follow-up. The Knee Society knee score and functional score was improved from 43.0±16.9 points and 39.0±20.2 points preoperatively to 95.1±5.8 points and 51.8±21.2 points at the latest follow-up, respectively in Group A. The Knee Society knee score and functional score was improved from 37.1±16.7 points and 31.9±18.4 points preoperatively to 92.5±8.7 points and 53.1±26.1 points at the latest follow-up, respectively in Group B. Kaplan-Meier survivorship at 10-year was 95.5% in Group A and 96.2% in Group B with any operation as the end point. The survivorship between Group A and Group B was not statistically significant.

Good range of flexion was maintained and Knee society score was excellent after a long time follow-up for the patients who achieved deep flexion after TKA. Deep flexion was proved not to affect long term durability in this Bi-Surface Knee System.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 416 - 416
1 Nov 2011
Nakamura T Fukuda C Imamura M Goto K Kokubo T
Full Access

Many types of bioactive bone cement have been developed to overcome the disadvantages of polymethyl-methacrylate (PMMA) bone cement, especially its lack of bone-bonding ability, which occasionally leads to aseptic loosening of prostheses used for arthroplasty. Earlier, we showed that bioactive bone cements containing either nano-sized or micron-sized titania (TiO2) particles had excellent in vivo osteoconductivity.

However, anatase phase titania particles contained in these bioactive bone cements raise concerns about their safety in vivo. We developed pure rutile micron-sized titania particles. because rutile is the only stable phase, whereas anatase is metastable.

In this study, polymethylmethacrylate (PMMA)-based bone cement containing pure rutile micron-sized titania (TiO2) particles were developed, and their mechanical properties and osteoconductivity are evaluated. The three types of bioactive bone cement were T10, T20, and T30, which contained 10, 20, and 30wt% TiO2, respectively.

Commercially available PMMA cement (PMMAc) was used as a control. Hardened cylindrical cement sample (φ2.5mm*10mm) was inserted manually on rabbit femur vertically. Push out test was performed for evaluation of bonding strength. For mechanical testing, the flexural strength, flexural modulus, and compressive strength were measured.

Results of this study revealed that polymethylmeth-acrylate (PMMA)-based bone cement containing pure rutile micron-sized titania particles has outstanding osteoconductivity in vivo, and their mechanical properties were exceeded that of commercially available PMMA cement. Interfacial shear strength of T10, T20 and T30 were 17.1~24.0MPa each at 12 weeks, and were significantly higher than PMMAc. In general, the interfacial bonding strength of bone cement depends mainly on its interdigitation with cancellous tissue, which is accomplished by the pressurized injection of the cement in paste form. On the other hand, we inserted the hardened specimens into oversized holes on rabbit femur in this study, because we intended to examine the osteoconductive and bone-bonding potentials of each material. The flexural strength, flexural modulus, and compressive strength were equivalent to or exceeded that of PMMAc.

These results show that bone cement containing pure rutile micron-sized titania particles is a promising material applied to prosthesis fixation as well as vertebroplasty.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 413 - 413
1 Nov 2011
Goto K Akiyama H Kawanabe K Sou K Nakamura T
Full Access

Poly-L-lactic acid (PLLA) is characterized by its biocompatibility and biodegradability, and is used clinically. In our hospital, we started to use PLLA screws instead of metallic or ceramic screws in the fixation of acetabular bone grafts in total hip arthroplasty (THA) in 1990, because there were concerns about the use of rigid and nonbioabsorble screws, which might contribute to the absorption of the grafted bone and induce metallosis or third-body wear when breakage of the screws occurs. The purpose of this study was to review a series of cemented THA for dysplasia, with structural autograft fixed with PLLA screws. We focused on the survival rate of the acetabular component and radiological change of the grafted bone–socket interface.

This study included 104 consecutive cemented total hip arthroplasties (80 patients) performed between July 1990 and December 1995 in our hospital. All patients were followed over 10 years and reviewed retrospectively. The grafted bone trimmed from the excised femoral head was fixed rigidly with 1 or 2 PLLA screws (cancellous lag screws 6.5 mm in bore diameter and 4.1 mm in grove diameter) (Fixsorb; Takiron Co., Ltd., Osaka, Japan).

X-ray photographs taken just after the primary operation showed an obscure but still visible radiolu-cent region corresponding to the inserted PLLA screws in many cases.

However, X-ray photographs at the final follow-up showed an unclear radiolucent zone at the sites of the PLLA screws, and the osteosclerotic line surrounding the site where the radiolucent zone had been found was confirmed in only 4 cases. Bone union was confirmed radiologically at the grafted site in every case, and there were no cases of early collapse or extravasation of the grafted bone. No positive resorption of the grafted bone was observed in any case. Kaplan–Meier survivorship analysis of socket revision, radiological loosening of the socket, and the appearance of a radiolucent line > 1 mm in the graft–socket interface as the endpoints indicated survival rates of 99%, 97.1%, and 63.5% at 10 years, and 96.6%, 90.2%, and 56.1% at 15 years, respectively.

The results of this study indicated that PLLA screws are safe and useful for the fixation of acetabular bone graft concomitant to cemented THA with a careful rehabilitation program. However, because of concern about the mechanical insufficiency of the PLLA screws for THA with an early weight-bearing rehabilitation program, we have used mechanically stronger and bioabsorbable screws made of forged composites of hydroxyapatite and PLLA since 2003.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 518 - 518
1 Oct 2010
Hirano F Fujii H Mori T Nakamura T Ohnishi H Okabe S Tanaka S Tsurukami H Uchida S
Full Access

Purpose: There is no report concerning about long-term comparison result of high placed cementless cup stability with or without screws for developmental dysplasia of the hip. The aim of this study was to ascertain whether or not there are any differences in high placed cementless cup stability with or without screws at the mean 10-year (6–14) follow-up period.

Method: We divided 109 hip-cases who underwent identical cementless total hip arthoplasty system (Mallory – Head : Biomet Inc.) to two groups: 57 cups with screw (screw group) and 52 cups without screw (no screw group). No case in both group underwent bulk bone graft for acetabular roof. Radiographic signs of cup instability were defined as the development of radiolucent line (> 2mm) or migration (> 4mm). Degree of subluxation by Crowe classification, cup size and cup abduction angle were also measured.

Results: In both groups, there was no significant difference in terms of degree of subluxation (each grade’s %) (screw vs no screw = I (68, 73), II (21, 25), III (11,0), IV (0, 2)), age (yrs) (58, 60), cup size (mm) (46, 47) and cup abduction angle (49, 47). In screw group, one case was revised by replacing only polyethylene insert due to excessive ware. No case in both group showed any sign of component instability.

Conclusion: High placed Mallory-Head type cementless cup without screws showed stable radiographic fixation as well as cup with screws at mean 10 years follow-up period.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 111 - 111
1 Mar 2010
Akiyama H Kawanabe K Goto K So K Nakamura T
Full Access

Removal of femoral bone cement is required for preparation of proper implant bed for reimplantation of a new femoral component in revision total hip arthroplasty. Several devices and procedures have been developed for cement removal, including an extracorporal shock-wave lithotripter and YAG laser, as well as a high-powered drill or burr under the control of conventional fluoroscopic images and an intrafemoral endoscopy. Ultrasonic tools are efficient for removal of bone cement with minimal damage to bone. We use a high-powered burr to remove the deep femoral bone cement under the control of conventional fluoroscopic images, although the problem of this procedure is large exposure of X-ray and two dimensional viewing of burr position which can result in perforation in the third plane.

Computer-assisted fluoroscopic navigation system allows the surgeons to provide positional information about surgical instrument to target bones during operations. Two-dimensional image data are obtained using the fluoroscope with a reference frame and stored on a computer workstation. A camera interfaced with the computer then tracks the position of the patient and registered surgical instruments during the procedure. Taking advantage of the real-time guidance of computer-assisted fluoroscopic navigation system, we introduce a valuable technique using computer-assisted fluoroscopic navigation system for performing removal of the cement of the femoral canal in revision cemented total hip arthroplasty.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 93 - 93
1 Mar 2010
Yamaguchi S Kizuki T Takadama H Matsushita T Kokubo T Nakamura T
Full Access

Titanium alloys such as Ti-6Al-4V and Ti-6Al-7Nb have been widely used as orthopedic implants such as artificial hip joint, because of their high mechanical strengths and good biocompatibilities. Recently, new kinds of titanium-based alloys free from elements such as V and Al, which are suspicious for cytotoxicities, are being developed. Ti-15Zr-4Ta-4Nb (Ti-15-4-4) is one of such alloys and shows high mechanical strength and corrosion resistance which are comparable to those of the Ti-6Al-4V alloy. In the present study, chemical treatments for providing bone-bonding ability to this alloy were investigated. Apatite-forming ability in a simulated body fluid (SBF) was used as an indication of the bone-bonding ability.

Ti-15-4-4 alloy plates 10×10×1 mm3 in size were soaked in 5M-NaOH solution at 60 °C for 24 h, soaked in 100mM-CaCl2 solution at 40 °C for 24 h, heated at 600 °C for 1 h and then soaked in hot water at 80 °C for 24 h. Surface structural changes of the alloy with these treatments were analyzed by a field emission scanning electron microscope (FE-SEM) attached with an energy-dispersive X-ray spectrometer (EDX), Thin-film X-ray diffraction (TF-XRD) and Fourier transform confocal laser Raman spectroscopy (FT-Raman). Scratch resistance of surface layer of the alloy was measured by a thin-film scratch tester. Apatite-forming ability of the specimens was examined by soaking them in SBF for 3 days. Long-term stability of the apatite-forming ability was examined after keeping the specimens in an incubator with relative humidity of 95 % at 80 °C for 1 week.

A sodium hydrogen titanate layer about 500 nm in thickness was formed on the surface of the alloy by the NaOH treatment. This specimen formed some amounts of apatite in SBF within 3 days, but its scratch resistance was as low as less than 10 mN. When the NaOH-treated specimen was subsequently heat treated, the sodium hydrogen titanate transformed into sodium titanate to give scratch resistance as high as 92 mN, but lost its apatite-forming ability.

When the NaOH-treated specimen was soaked in CaCl2 solution, the sodium hydrogen titanate was isomorphously transformed into calcium hydrogen titanate. Thus treated specimen increased its apatite-forming ability, but its scratch resistance was still low. When the NaOH- and CaCl2-treated specimen was subsequently heat treated, the calcium hydrogen titanate transformed into calcium titanate to give scratch resistance as high as 169 mN. However, its apatite-forming ability was lost. Thus treated specimen was then soaked in hot water. As a result, its apatite-forming ability remarkably increased without decreasing scratch resistance. It showed high apatite-forming ability even after a long-term-stability test.

The NaOH-, CaCl2-, heat- and hot-water-treated Ti-15-4-4 alloy is believed to be promising materials for artificial joints, because of its high apatite-forming ability with long-term stability as well as high scratch resistance.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 93 - 93
1 Mar 2010
Kawanabe K Akiyama H Goto K Tanaka K Fujibayashi S Nakamura T
Full Access

Kokubo and one of the present authors (T.N) have developed a new technique of bioactive coating using alkaline and heat treatment, which induces the formation of a thin HA layer on the surface of titanium after implantation in the body. This new coating technique is not associated with degradation or separation of the HA coating, because a bone-like apatite layer of 1 μm in width begins to form in the body tissue after implantation.

Chemically and thermally treated titanium possesses bone-bonding ability, which has been confirmed by detachment tests. Bone ingrowth into bioactive titanium continues to increase throughout the 26 weeks of implantation, whereas bone ingrowth into non-treated or HA plasma coating implants tends to decrease between 6 and 12 weeks. These findings suggest the long-term stability and osteoconduction of the bioactive layer of chemically and thermally treated titanium.

We carried out a series of 70 cementless primary total hip arthroplasties using this coating technique on a porous titanium surface, and followed up the patients for a mean period of 4.8 years. There were no instances of loosening or revision, or formation of a reactive line on the porous coating. Although radiography just after surgery showed a gap between the host bone and the socket in 70% of cases, all the gaps disappeared within a year, indicating the good osteoconduction provided by the coating. Alkaline-heat treatment of titanium to provide a HA coating has several advantages over plasma-spraying, including no degeneration or absorption of the HA coating, simplicity of the manufacturing process, and cost effectiveness. In addition, this method allows homogeneous deposition of bone-like apatite within a porous implant.

Although this was a relatively short-term study, treatment that creates a bioactive surface on titanium and titanium alloy implants has considerable promise for clinical application.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 178 - 178
1 Mar 2008
Nakamura T Ito H Atsuta Y Tanino H Nishimura I Shimizu R Ishida T Mitamura Y Matsuno T
Full Access

Thigh pain appears often after THA used of the cement-less femoral components, but the appearance mechanism of thigh pain does not have been elucidated. As one factor of manifestation of thigh pain, it has been guessed that the pressure from the inside of medullary cavity of bone by the stem. The purpose of this study is confirming whether the flexor reflex is caused, by using the femur of a rabbit that applied the pressure from the inside of medullary cavity of bone.

Japanese white rabbits with weight of about 3kg were used. Evaluation of the appearance of the pain by the pressure was performed by measurement of the hind leg flexor activity produced by the flexor reflex. After confirming that appearance of the muscles activity by the pain reflex from adding the pain stimulus to the hind leg skin of rabbits, we loaded of the pressure into the inside of medullary cavity of bone and observed whether the muscles activity appears. As the laboratory animals model, we prepared two kinds of rabbits by the difference in the amount of reaming. And we tested how the differences show up between these two kinds of rabbits.

In the rabbits with few amounts of reaming, the flexor reflex appeared in low pressure. But, in the rabbits with many amounts of reaming, the flexor reflex did not appear in high pressure, either.

It is known that the somatic sensory nerves are distributed in the bone, and it is known that the sensory nerve ends exist in the medullary cavity of bone. It was suggested that the pain is induced, when the sensory nerve ends remained in the inside of medullary cavity of bone and the pressure in whicha reaction is possible was carried out there.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 169 - 169
1 Mar 2008
Ito H Matsuno T Nakamura T Minami A
Full Access

We evaluated intermediate-term results of primary cementless Omniflex prostheses.

Forty-nine patients (57 hips) with a mean age of 44 years were observed for an average of 8.6 years.

These results were inferior to those using other recent cementless total hip systems. The increasing prevalence of loosening and osteolysis with time are problems related to this Omniflex femoral component. Although the implant design is unique, the authors no longer use this system.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 187 - 187
1 Mar 2008
Tamura J Kawanabe K Shimizu M Ohnishi E Nakamura T
Full Access

We have developed bioactive bone cements manufactured from bioactive glass-ceramic powder and BIS-GMA resin, which has the bone-bonding ability. In the present clinical trial, this bioactive bone cement was used for fixation of total hip arthroplasty (THA) and the clinical results were investigated

Two types of bioactive bone cements (high- and low- viscosity type cements) were prepared (Nippon Electric Glass Co. Ltd.). Inorganic filler contained 72.0 wt% AW-GC (apatite and wollastonite containing glass-ceramic) and 27.0 wt% SiO2 powder. All surgery was performed at Kyoto University Hospital between February and October 1996. 20primary THA (20 patients) were performed using bioactive bone cement as a clinical trial. The average age of the patients was 58 years. The average follow-up period was 6 years, 9 months. The diagnosis for 18 hips at the operation was osteoarthritis and 2 hips were rheumatoid arthritis. All sockets and one stem were fixed by bioactive cement, and all but one stem were fixed by PMMA cement. In all cases all polyethylene socket and titanium stem were used (14 KC type THA and 8 KMAX type THA). For the femoral head 22 mm diameter alumina head was used in all cases.

If the bone cement is bioactive and shows direct bonding with the bone, wear particles can’t enter the interface and thus prevention of loosening due to bone resorption would be expected. This cement demonstrated satisfactory clinical results, proving to be a promising material for implant fixation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 177 - 178
1 Mar 2008
Nakamura T Liang B Ohnish D Ise K Kawanabe K
Full Access

Zirconia ceramic femoral head has better mechanical properties than those alumina head has. However, it is concerning whether the wear of UHMWPE against zirconia head is as low as that of alumina head. We compared polyethylene wears against 22.225mm alumina and zirconia heads in total hip arthroplasties (THA) occupied in our hospital.

Kobelco hip prostheses (Kobelco, Kobe, Japan) were used. Titanium alloy stem was cement-fixed and all-polyethylene acetabular components were articulated with alumina or zirconia femoral heads. In the cases from February 1996 to December 1998, 96 primary cemented total hip arthroplasties (THA) in 87 patients of osteoarthritis were observed with a minimum follow-up of five years. The clinical results were evaluated using JOA hip score (100 in normal hip). There were 46 hips with alumina heads and mean follow-up of 6.2 years, and 51 hips with zirconiaheads and mean follow-up of 5.2 years. Mean ages at operation were 58 years. For each patient, the initial postoperative and the latest anterior-posterior radiographs of the pelvis were selected. With the custom software Image-Pro Plus version 4.0, linear wear and volumetric wear were measured.

Clinical results of both heads showed no difference. Linear wear rate of alumina is 0.080±0.047mm/year, while it is 0.147±0.069mm/year for zirconia, significantly higher than alumina (p?0.0001). Volumetric wear rate of zirconia (42.499±20.233mm3/year) is also significantly higher than alumina (27.049±17.216mm3/year) (p?0.0001).

The low thermal conductivity of zirconia is thought to cause local high temperature, leading to the phase transformation and lower-temperature aging degeneration (LTAD) of zirconia head surface. In order to solve this problem, alumina-adding zirconia compound ceramics with lower phase transformation were developed. Hip simulator test revealed much lower wear rate of improved zirconia. This will be discussed.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 172 - 172
1 Mar 2008
Yagihashi K Nishimura I Ishida T Ito H Tanino H Nakamura T Matsuno T Mitamura Y
Full Access

Prosthetic impingement after THA is to different for the angle and shape of the implant. Purpose of this study is examine the range of motion(ROM) on a computer when angle and shape of the implant are changed.

The 3D implant models were created on a computer. The angle was measured in the flexion, extension, adduction direction byevery 0.1 degrees. There are three kinds of acetabular abduction angle, two kinds of acetabular anteversion angle and two kinds of femoral anteversion angle. There are three kinds of the radius of neck and the neck shaft angle. All 324 patterns of the above model were measured.

When the radius of neck decreased, the ROM increased in all cases. When the neck shaft angle decreased, the ROM increased by almost all cases. When the acetabular anteversion angle increased, the ROM of flexion direction increased and adduction direction decreased, and as for the extension direction, all the factors had influenced the change in the ROM. When the acetabular angle increased, the ROM of the extension direction increased and the flexion directions decreased. As for adduction direction, femoral anteversion angle, acetabular anteversion angles, and the radius of neck had influenced the ROM. When the femoral anteversion angle increased, the ROM of flexion direction increased and extension, adduction direction decreased.

The clinical ROM is affected by the impingement of non-implant and the strain of the soft tissue. Therefore, It’ s considered that the clinical ROM is smaller than the ROM which was investigated in this study in many cases. When the radius of neck and the neck shaft angle decrease, the increase of the ROM expected. However the radius of the neck should not be decreased too much to avoid the decrease of the neck strength.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 398 - 398
1 Apr 2004
Nishiguchi S Fujibayashi S Kim H Kokubo T Nakamura T
Full Access

In cementless fixation system, surface character becomes important factor. Alkali and heat treatments on titanium metal has been proved to show strong bonding to bone and higher ongrowth rate. In this study we examined the effect of alkali and heat treatments on titanium rod in rabbit femur intramedurally model, in consideration of cementless hip stem. The implant had a 5mm in diameter and 25 mm in length. The implants were and half of them were immersed in 5 mol/L sodium hydroxide solution and heated at 600 åé for one hour (AH implant), and the other half were untreated (CL implant). The implants were implanted into the distal femur of the rabbits, AH implant into left femur and CL implants into right. The bone-implant interfaces were evaluated at 3, 6, and 12 weeks after implantations.

Pull-out tests showed that AH implants significantly higher bonding strength to bone than CL implants at each week after operations. At 12 weeks mean pull-out load of AH implants was 411.7 N and that of CL implants 72.2 N. As postoperative time elapsed, histological examination revealed that new bone form on the surface of the both types of the implants, but significantly more bone contacted directly on the surface of AH implants. At 12 weeks AH implant was covered by the newly formed bone about 56% of the whole surface of the implants and CL implants was about 19%.

In conclusion, alkali- and heat-treated titanium offers strong bone-bonding and high affinity to bone instead of conventional mechanical interlocking mechanism. Alkali and heat treatments on titanium may be applicable to the surface treatment for cementless joint replacement implant.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 34 - 34
1 Jan 2003
Iida H Matsusue Y Kawanabe K Nakamura T
Full Access

The results of 278 consecutive primary total hip arthroplasties performed with bone grafting for ace-tabular bone deficiencies were reviewed at an average of 9.0 years (range, 5–23) after surgery. All patients had underlying developmental dysplasia of the hip. For all hips, the grafts used were from the patients’ own resected femoral heads. All but three grafts were screwed to the supero-lateral aspect of the acetabular roof, the exceptions being grafts without internal fixation. Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component at 10 years of 97% (95% confidence interval (CI), 94–100%) with revision for aseptic loosening as the endpoint, and of 82% (95% CI, 76–89%), when radiological loosening was used. Trabecular reorientation, as an indicator of graft incorporation, was seen in 89% of the joints between 1.5 and 5 years (mean 3 years), and delayed up to 7 years. Parametric survivorship analysis using the Cox proportional-hazards model indicated that trochanteric non-union, lateral placement of the socket, and delayed trabecular re-orientation of the bone graft, were risk factors for loosening of the acetabular component. Autogenous acetabular bone grafting will be of value for long-term success and has good potential for additional improvement of the results, provided these three risk factors are reduced. In order to promote the trabecular reorientation, we have gradually improved the surgical technique including sizing of bone graft and adaptation technique. By these alterations of the surgical technique, trabecular reorientation of the 51 joints operated after 1993 was completed by 4 years after surgery.