Advertisement for orthosearch.org.uk
Results 1 - 50 of 578
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims. We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. Methods. The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. Results. The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. Conclusion. We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability. Cite this article: Bone Joint J 2022;104-B(10):1126–1131


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 37 - 42
1 Jan 2008
Nutton RW van der Linden ML Rowe PJ Gaston P Wade FA

Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of whom received each design, were assessed pre-operatively and at one year after operation using knee scores and analysis of range of movement using electrogoniometry. For both implant designs there was a significant improvement in the function component of the knee scores (p < 0.001) and the maximum range of flexion when walking on the level, ascending and descending a slope or stairs (all p < 0.001), squatting (p = 0.020) and stepping into a bath (p = 0.024). There was no significant difference in outcome, including the maximum knee flexion, between patients receiving the standard and high flexion designs of this implant


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 87 - 93
1 Jun 2021
Chalmers BP Elmasry SS Kahlenberg CA Mayman DJ Wright TM Westrich GH Imhauser CW Sculco PK Cross MB

Aims. Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture, which leads to femoral joint line elevation. There is a paucity of data describing the effect of joint line elevation on mid-flexion stability and knee kinematics. Thus, the goal of this study was to quantify the effect of joint line elevation on mid-flexion laxity. Methods. Six computational knee models with cadaver-specific capsular and collateral ligament properties were implanted with a posterior-stabilized (PS) TKA. A 10° flexion contracture was created in each model to simulate a capsular contracture. Distal femoral resections of + 2 mm and + 4 mm were then simulated for each knee. The knee models were then extended under a standard moment. Subsequently, varus and valgus moments of 10 Nm were applied as the knee was flexed from 0° to 90° at baseline and repeated after each of the two distal resections. Coronal laxity (the sum of varus and valgus angulation with respective maximum moments) was measured throughout flexion. Results. With + 2 mm resection at 30° and 45° of flexion, mean coronal laxity increased by a mean of 3.1° (SD 0.18°) (p < 0.001) and 2.7° (SD 0.30°) (p < 0.001), respectively. With + 4 mm resection at 30° and 45° of flexion, mean coronal laxity increased by 6.5° (SD 0.56°) (p < 0.001) and 5.5° (SD 0.72°) (p < 0.001), respectively. Maximum increased coronal laxity for a + 4 mm resection occurred at a mean 15.7° (11° to 33°) of flexion with a mean increase of 7.8° (SD 0.2°) from baseline. Conclusion. With joint line elevation in primary PS TKA, coronal laxity peaks early (about 16°) with a maximum laxity of 8°. Surgeons should restore the joint line if possible; however, if joint line elevation is necessary, we recommend assessment of coronal laxity at 15° to 30° of knee flexion to assess for mid-flexion instability. Further in vivo studies are warranted to understand if this mid-flexion coronal laxity has negative clinical implications. Cite this article: Bone Joint J 2021;103-B(6 Supple A):87–93


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims. To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. Methods. In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used. Results. Overall mean ROM in stiff knees increased preoperatively from 67° (0° to 80°) to 114° postoperatively (65° to 135°) (p < 0.001). Mean knee flexion improved from 82° (0° to 110°) to 115° (65° to 135°) and mean flexion contracture decreased from 14° (0° to 50°) to 1° (0° to 10°) (p < 0.001). The mean Knee Society Score (KSS) improved from 34 (0 to 71) to 88 (38 to 100) (p < 0.001) and the KSS Functional Score from 43 (0 to 70) to 86 (0 to 100). Seven knees (7%) required manipulations under anaesthesia (MUA) and none of the knees had flexion instability. The mean overall ROM in the control group improved from 117° (100° to 140°) to 123° (100° to 130°) (p < 0.001). Mean knee flexion improved from 119° (100° to 140°) to 123° (100° to 130°) (p < 0.001) and mean flexion contracture decreased from 2° (0° to 15°) to 0° (0° to 5°) (p < 0.001). None of the knees in the control group had flexion instability or required MUA. The mean KSS Knee Score improved from 48 (0 to 80) to 94 (79 to 100) (p < 0.001) and the KSS Functional Score from 52 (5 to 100) to 95 (60 to 100) (p < 0.001). Mean improvement in ROM (p < 0.001) and KSS Knee Score (p = 0.017) were greater in knees with preoperative stiffness compared with the control group, but the KSS Functional Score improvement was comparable (p = 0.885). Conclusion. TKA with a 2 mm increased flexion gap provided a significant improvement of ROM in knees with preoperative stiffness. While the improvement in ROM was greater, the absolute postoperative ROM was less than in matched non-stiff knees. PS TKA with patellar resurfacing and a 2 mm increased flexion gap, in combination with adequate soft tissue balancing, provides excellent ROM and knee function when stiffness of the knee had been present preoperatively. Cite this article: Bone Joint J 2020;102-B(4):426–433


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1477 - 1481
1 Nov 2017
Hernandez NM Taunton MJ Perry KI Mara KC Hanssen AD Abdel MP

Aims. Patients with flexion instability after total knee arthroplasty (TKA) often present with a recurrent effusion, which may be a haemarthrosis. While the radiographic factors contributing to flexion instability have been elucidated, the clinical diagnosis remains challenging. Our aim, in this study, was to determine the mean white cell count and differential profile in pre-operative aspirations of synovial fluid in a consecutive series of patients undergoing revision TKA for flexion instability. Patients and Methods. Between 2000 and 2010, 60 patients undergoing aseptic revision TKA for flexion instability were identified. The results of the pre-operative aspiration of synovial fluid were available for 53 patients (88%). These patients were 1:2 matched to 106 patients who underwent aseptic TKA for indications other than flexion instability. The mean age of the patients at revision TKA was 65 years (44 to 82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2). Results. In the flexion instability group, the median total cell count was 312 cells/µL (interquartile range (IQR) 104 to 624), with a mean distribution of 45% macrophages (2% to 90%), 30% lymphocytes (1% to 69%), 18% neutrophils (0% to 80%), 0.5% eosinophils (0% to 6%) and 7% other cells (0% to 42%; mainly synovial cells). There was no significant difference in the median total cell count (p = 0.14) or mean distribution of macrophages (p = 0.42), lymphocytes (p = 0.38), neutrophils (p = 0.19) and eosinophils (p = 0.89) between the flexion instability and control groups. There was a significant difference in the percentage of bloody serosanguineous aspirations which was 58% in the flexion instability group and 18% in the control group (odds ratio = 6.5; p = 0.0001). Conclusions. In the group of patients who underwent revision TKA for flexion instability, most had a mean cell count and differential similar to those who underwent revision for other aseptic indications. However, bloody serosanguineous aspirations were 6.5 times more common in those with flexion instability confirming that many of the recurrent effusions seen in this condition are haemarthroses. Cite this article: Bone Joint J 2017;99-B:1477–81


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 36 - 42
1 Jun 2020
Nishitani K Kuriyama S Nakamura S Umatani N Ito H Matsuda S

Aims. This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes. Methods. A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle. Results. According to the mean and SD of γ angle (γ, 4.0 SD 3.0°), four groups (Extended or minor flexed group, −0.5° ≤ γ < 2.5° (n = 54)), Mild flexed group (2.5° ≤ γ < 5.5° (n = 63)), Moderate flexed group (5.5° ≤ γ < 8.5° (n = 26)), and Excessive flexed group (8.5° ≤ γ (n = 13)) were defined. The Excessive flexed group showed worse 2011KSSs in all subdomains (Symptoms, Satisfaction, Expectations, and Functional activities) than the Mild flexed group. Secondary regression showed a convex upward function, and the scores were highest at γ = 3.0°, 4.0°, and 3.0° in Satisfaction, Expectations, and Functional activities, respectively. Conclusion. The groups with a sagittal alignment of the femoral component > 8.5° showed inferior clinical outcomes in 2011KSSs. Secondary regression analyses showed that mild flexion of the femoral component was associated with the highest score. When implanting the Bi-Surface Knee prosthesis surgeons should pay careful attention to avoiding flexing the femoral component extensively during TKA. Our findings may be applicable to other implant designs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):36–42


Bone & Joint Open
Vol. 4, Issue 6 | Pages 432 - 441
5 Jun 2023
Kahlenberg CA Berube EE Xiang W Manzi JE Jahandar H Chalmers BP Cross MB Mayman DJ Wright TM Westrich GH Imhauser CW Sculco PK

Aims. Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model. Methods. We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition. Results. Mid-level inserts reduced varus angulations compared to PS inserts by a median of 0.4°, 0.9°, and 1.5° at 0°, 30°, and 90° of flexion, respectively, and reduced valgus angulations by a median of 0.3°, 1.0°, and 1.2° (p ≤ 0.027 for all comparisons). Mid-level inserts reduced net IE rotations by a median of 5.6°, 14.7°, and 17.5° at 0°, 30°, and 90°, respectively (p = 0.012). Mid-level inserts reduced anterior tibial translation only at 90° of flexion by a median of 3.0 millimetres (p = 0.036). With an applied varus moment, the mid-level insert decreased LCL force compared to the PS insert at all three flexion angles that were tested (p ≤ 0.036). In contrast, with a valgus moment the mid-level insert did not reduce MCL force. With an applied internal rotation moment, the mid-level insert decreased LCL force at 30° and 90° by a median of 25.7 N and 31.7 N, respectively (p = 0.017 and p = 0.012). With an external rotation moment, the mid-level insert decreased MCL force at 30° and 90° by a median of 45.7 N and 20.0 N, respectively (p ≤ 0.017 for all comparisons). With an applied anterior load, MCL and LCL forces showed no differences between the two inserts at 30° and 90° of flexion. Conclusion. The mid-level insert used in this study decreased coronal and axial plane laxities compared to the PS insert, but its stabilizing benefit in the sagittal plane was limited. Both mid-level and PS inserts depended on the MCL to resist anterior loads during a simulated clinical exam of anterior laxity. Cite this article: Bone Jt Open 2023;4(6):432–441


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 112 - 115
1 Nov 2012
Su EP

Fixed flexion deformities are common in osteoarthritic knees that are indicated for total knee arthroplasty. The lack of full extension at the knee results in a greater force of quadriceps contracture and energy expenditure. It also results in slower walking velocity and abnormal gait mechanics, overloading the contralateral limb. Residual flexion contractures after TKA have been associated with poorer functional scores and outcomes. Although some flexion contractures may resolve with time after surgery, a substantial percentage will become permanent. Therefore, it is essential to correct fixed flexion deformities at the time of TKA, and be vigilant in the post-operative course to maintain the correction. Surgical techniques to address pre-operative flexion contractures include: adequate bone resection, ligament releases, removal of posterior osteophytes, and posterior capsular releases. Post-operatively, extension can be maintained with focused physiotherapy, a specially modified continuous passive motion machine, a contralateral heel lift, and splinting


Bone & Joint Open
Vol. 2, Issue 11 | Pages 974 - 980
25 Nov 2021
Allom RJ Wood JA Chen DB MacDessi SJ

Aims. It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. Methods. A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance. Results. In TKAs with a stressed medial-lateral gap difference of ≤1 mm, 147 (89%) had an ICLD of ≤15 lb in extension, and 112 (84%) had an ICLD of ≤ 15 lb in flexion; 157 (95%) had an ICLD ≤ 30 lb in extension, and 126 (94%) had an ICLD ≤ 30 lb in flexion; and 165 (100%) had an ICLD ≤ 60 lb in extension, and 133 (99%) had an ICLD ≤ 60 lb in flexion. With a 0 mm difference between the medial and lateral stressed gaps, 103 (91%) of TKA had an ICLD ≤ 15 lb in extension, decreasing to 155 (88%) when the difference between the medial and lateral stressed extension gaps increased to ± 3 mm. In flexion, 47 (77%) had an ICLD ≤ 15 lb with a medial-lateral gap difference of 0 mm, increasing to 147 (84%) at ± 3 mm. Conclusion. This study found a strong relationship between intercompartmental loads and gap symmetry in extension and flexion measured with prostheses in situ. The results suggest that ICLD and medial-lateral gap difference provide similar assessment of soft-tissue balance in robotic arm-assisted TKA. Cite this article: Bone Jt Open 2021;2(11):974–980


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1514 - 1525
1 Sep 2021
Scott CEH Holland G Gillespie M Keenan OJ Gherman A MacDonald DJ Simpson AHRW Clement ND

Aims. The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA. Methods. This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and anterior femoral offset were measured radiologically. At two to four years postoperatively, 151 patients with a mean age of 70.0 years (SD 9.44) were included. Their mean BMI was 30.4 kg/m. 2. (SD 5.36) and 60 were male (40%). They completed EQ-5D, OKS, and Kujala scores, assessments of the ability to kneel, and a visual analogue scale for anterior knee pain and satisfaction. Results. The ability to kneel in the four positions improved in between 29 (19%) and 53 patients (35%) after TKA, but declined in between 35 (23%) and 46 patients (30%). Single-leg kneeling was most important to patients. After TKA, 62 patients (41%) were unable to achieve a single-leg kneel, 76 (50%) were unable to achieve a double-leg kneel, 102 (68%) were unable to achieve a high-flexion kneel and 61 (40%) were unable to achieve a praying position. Posterolateral cartilage loss significantly affected preoperative deep flexion kneeling (p = 0.019). A postoperative inability to kneel was significantly associated with worse OKS, Kujala scores, and satisfaction (p < 0.05). Multivariable regression analysis identified significant independent associations with the ability to kneel after TKA (p < 0.05): better preoperative EQ-5D and flexion of the femoral component for single-leg kneeling; the ability to achieve it preoperatively and flexion of the femoral component for double-leg kneeling; male sex for high-flexion kneeling; and the ability to achieve it preoperatively, anterior femoral offset, and patellar cartilage loss for the praying position. Conclusion. The ability to kneel was important to patients and significantly influenced knee-specific PROMs, but was poorly restored by TKA with equal chances of improvement or decline. Cite this article: Bone Joint J 2021;103-B(9):1514–1525


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 604 - 608
1 May 2007
Park KK Chang CB Kang YG Seong SC Kim TK

This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year postoperatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1° (60° to 160°) to 133.0° (105° to 150°). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120°, we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9 vs 47.3, p = 0.031). Knees with a maximum flexion of more than 135° had a better functional Western Ontario McMasters Universities Osteoarthritis index score than knees with maximum flexion of 135° or less (17.5 vs 14.3, p = 0.031). We found only weak correlation between the postoperative maximum flexion and the clinical parameters for pain relief, function and quality of life, even in Korean patients. Efforts to increase post-operative maximum flexion should be exercised with caution until concerns relating to high-flexion activities are sufficiently resolved


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed. Results. Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129° (95% confidence interval (CI) 127° to 131°) was greater in the PS group than in the CR (120° (95% CI 121° to 124°)) and AS groups (122° (95% CI 120° to 124°)). Conclusion. Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear. Cite this article: Bone Joint J 2023;105-B(12):1271–1278


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims. The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases. Methods. Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases. Results. The use of E-rKA helped restore all knees within the predefined boundaries, with appropriate soft-tissue balancing. E-rKA compared with MA resulted in reduced residual medial tightness following surgical planning, in full extension (2.71 mm (SD 1.66) vs 5.16 mm (SD 3.10), respectively; p < 0.001), and 90° of flexion (2.52 mm (SD 1.63) vs 6.27 mm (SD 3.11), respectively; p < 0.001). Among the study population, 156 patients (78%) were managed with minor adjustments in component positioning alone, while 44 (22%) required additional soft-tissue releases. The mean errors in postoperative alignment were 0.53 mm and 0.26 mm among patients in group A and group B, respectively (p = 0.328). Conclusion. E-rKA is an effective and reproducible alignment strategy during RA-TKA, permitting a large proportion of patients to be managed without soft-tissue releases. The execution of minor alterations in component positioning within predefined multiplanar boundaries is a better starting point for gap management than soft-tissue releases. Cite this article: Bone Jt Open 2024;5(8):628–636


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1133 - 1136
1 Nov 2004
Tokuhara Y Kadoya Y Nakagawa S Kobayashi A Takaoka K

Varus and valgus joint laxity of the normal living knee in flexion was assessed using MRI. Twenty knees were flexed to 90° and were imaged in neutral and under a varus-valgus stress in an open MRI system. The configuration of the tibiofemoral joint gap was studied in slices which crossed the epicondyles of the femur. When a varus stress was applied, the lateral joint gap opened by 6.7 ± 1.9 mm (mean ± . sd. ; 2.1 to 9.2) whereas the medial joint gap opened by only by a mean of 2.1 ± 1.1 mm (0.2 to 4.2). These discrepancies indicate that the tibiofemoral flexion gap in the normal knee is not rectangular and that the lateral joint gap is significantly lax. These results may be useful for adequate soft-tissue balancing and bone resection in total knee arthroplasty and reconstruction surgery on ligaments


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 296 - 300
1 Mar 1999
Kim Y Cho S Kim J

Between June 1993 and December 1994, we performed total knee arthroplasty (TKA) on 27 knees in 24 patients with spontaneous bony ankylosis in severe flexion. The mean age at operation was 43.5 years (30 to 60). No patient had preoperative pain. Three were unable to walk and 21 could manage less than five blocks. The mean duration of the ankylosis was 18.7 years (13 to 25) and its mean position was 105° flexion (75 to 135). The preoperative Hospital for Special Surgery Knee Score of 60 points was improved to 87 at the final follow-up three to five years later. All knees were free from pain. The mean range of active flexion in 24 knees was 97° (78 to 115) and the mean arc of movement 91° (78 to 98). The mean fixed flexion deformity was 6° (0 to 25) and the extension lag 8° (0 to 25). Angular deformity was corrected to between 0° and 10° of valgus. Four patients were able to walk one block and 20 five to seven blocks. Thirteen knees (48%) showed some necrosis at the skin edge; one knee required arthrodesis and another resection arthroplasty. One had a recurrence of tuberculous infection requiring arthrodesis. One patient had a rupture of the quadriceps tendon. To date no prosthesis has required revision for loosening. Radiolucency of 1 mm or less about the tibial prosthesis was observed at follow-up in four of the 24 knees. Our results have shown that one-stage TKA and skeletal traction after operation can achieve correction of severe flexion deformity of the knee with marked improvement in the function and quality of life


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims. One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods. A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results. The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion. From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1051 - 1057
1 Aug 2012
Nutton RW Wade FA Coutts FJ van der Linden ML

This prospective randomised controlled double-blind trial compared two types of PFC Sigma total knee replacement (TKR), differing in three design features aimed at improving flexion. The outcome of a standard fixed-bearing posterior cruciate ligament-preserving design (FB-S) was compared with that of a high-flexion rotating-platform posterior-stabilised design (RP-F) at one year after TKR. The study group of 77 patients with osteoarthritis of the knee comprised 37 men and 40 women, with a mean age of 69 years (44.9 to 84.9). The patients were randomly allocated either to the FB-S or the RP-F group and assessed pre-operatively and at one year post-operatively. The mean post-operative non-weight-bearing flexion was 107° (95% confidence interval (CI) 104° to 110°)) for the FB-S group and 113° (95% CI 109° to 117°) for the RP-F group, and this difference was statistically significant (p = 0.032). However, weight-bearing range of movement during both level walking and ascending a slope as measured during flexible electrogoniometry was a mean of 4° lower in the RP-F group than in the FB-S group, with 58° (95% CI 56° to 60°) versus 54° (95% CI 51° to 57°) for level walking (p = 0.019) and 56° (95% CI 54° to 58°) versus 52° (95% CI 48° to 56°) for ascending a slope (p = 0.044). Further, the mean post-operative pain score of the Western Ontario and McMaster Universities Osteoarthritis Index was significantly higher in the RP-F group (2.5 (95% CI 1.5 to 3.5) versus 4.2 (95% CI 2.9 to 5.5), p = 0.043). Although the RP-F group achieved higher non-weight-bearing knee flexion, patients in this group did not use this during activities of daily living and reported more pain one year after surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1327 - 1330
1 Oct 2006
Tokuhara Y Kadoya Y Kanekasu K Kondo M Kobayashi A Takaoka K

The shape of the flexion gap in 20 normal knees was evaluated by axial radiography of the distal femur, and the results compared with those obtained in a previous study by MRI. The observed asymmetry was reduced by 29% using radiography, with a mean value of 3.6° (1.5° to 6.3°) compared with that obtained by MRI of 5.1° (2.6° to 9.5°), a mean discrepancy of 1.49°. The results obtained by radiography and MRI showed a strong correlation (r = 0.78). Axial radiography is acceptable for the evaluation of the flexion gap and is less expensive and more comfortable to perform than MRI. Additionally, no metallic artefact occurs when the radiological method is used for assessment after arthroplasty


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1354 - 1358
1 Oct 2013
Singh G Tan JH Sng BY Awiszus F Lohmann CH Nathan SS

The optimal management of the tibial slope in achieving a high flexion angle in posterior-stabilised (PS) total knee replacement (TKR) is not well understood, and most studies evaluating the posterior tibial slope have been conducted on cruciate-retaining TKRs. We analysed pre- and post-operative tibial slope differences, pre- and post-operative coronal knee alignment and post-operative maximum flexion angle in 167 patients undergoing 209 TKRs. The mean pre-operative posterior tibial slope was 8.6° (1.3° to 17°) and post-operatively it was 8.0° (0.1° to 16.7°). Multiple linear regression analysis showed that the absolute difference between pre- and post-operative tibial slope (p < 0.001), post-operative coronal alignment (p = 0.02) and pre-operative range of movement (p < 0.001) predicted post-operative flexion. The variance of change in tibial slope became larger as the post-operative maximum flexion angle decreased. The odds ratio of having a post-operative flexion angle < 100° was 17.6 if the slope change was > 2°. Our data suggest that recreation of the anatomical tibial slope appears to improve maximum flexion after posterior-stabilised TKR, provided coronal alignment has been restored. Cite this article: Bone Joint J 2013;95-B:1354–8


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 934 - 936
1 Jul 2005
Aderinto J Brenkel IJ Chan P

We investigated fixed flexion deformity (FFD) after total knee replacement (TKR). Data relating to 369 cruciate-retaining unilateral TKRs performed at a single institution were collected prospectively. Fixed flexion was measured pre-operatively and at one week, six months, 18 months, three years and five years after surgery. Using binary logistic regression, pre-operative FFD was a predictor of post-operative FFD > 10° at one week (p = 0.006) and six months (p = 0.003) following surgery. Gender was a predictor at one week (p = 0.0073) with 24% of women showing a FFD > 10° compared with 37% of men. We have shown that a gradual improvement in knee extension can be expected up to three years after surgery in knees with FFD. By this time residual FFD is mild or absent in the majority of patients, including those who had a severe pre-operative FFD


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 50 - 53
1 Jan 2002
Bellemans J Banks S Victor J Vandenneucker H Moemans A

Our purpose was to determine the mechanism which allows the maximum knee flexion in vivo after a posterior-cruciate-ligament (PCL)-retaining total knee arthroplasty. Using three-dimensional computer-aided design videofluoroscopy of deep squatting in 29 patients, we determined that in 72% of knees, direct impingement of the tibial insert posteriorly against the back of the femur was the factor responsible for blocking further flexion. In view of this finding we defined a new parameter termed the ‘posterior condylar offset’. In 150 consecutive arthroplasties of the knee, the magnitude of posterior condylar offset was found to correlate with the final range of flexion


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 218 - 222
1 Mar 2003
Shetty AA Tindall AJ Qureshi F Divekar M Fernando KWK

Total knee replacement and high tibial osteotomy are common orthopaedic operations with low complication rates. Such surgery is in close proximity to the popliteal artery (PA), the behaviour of which during flexion of the knee is poorly understood. We used Duplex ultrasonography to determine the distance of the PA from the posterior tibial surface at 0° and 90° of flexion in 100 knees. When the knee was flexed the PA was closer to the posterior tibial surface at 1 to 1.5 cm below the joint line in 24% and at 1.5 to 2 cm below the joint line in 15%. There was a high branching anterior tibal artery in 6% of knees. We provide an anatomical account to help to explain our findings by using cadaver dissections, arteriography and static MRI studies


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 915 - 918
1 Jul 2007
Hanratty BM Thompson NW Wilson RK Beverland DE

We have studied the concept of posterior condylar offset and the importance of its restoration on the maximum range of knee flexion after posterior-cruciate-ligament-retaining total knee replacement (TKR). We measured the difference in the posterior condylar offset before and one year after operation in 69 patients who had undergone a primary cruciate-sacrificing mobile bearing TKR by one surgeon using the same implant and a standardised operating technique. In all the patients true pre- and post-operative lateral radiographs had been taken. The mean pre- and post-operative posterior condylar offset was 25.9 mm (21 to 35) and 26.9 mm (21 to 34), respectively. The mean difference in posterior condylar offset was + 1 mm (−6 to +5). The mean pre-operative knee flexion was 111° (62° to 146°) and at one year postoperatively, it was 107° (51° to 137°). There was no statistical correlation between the change in knee flexion and the difference in the posterior condylar offset after TKR (Pearson correlation coefficient r = −0.06, p = 0.69)


Bone & Joint Open
Vol. 5, Issue 7 | Pages 592 - 600
18 Jul 2024
Faschingbauer M Hambrecht J Schwer J Martin JR Reichel H Seitz A

Aims

Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?

Methods

Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 84 - 88
1 Jan 2016
Vince K

The term mid-flexion instability has entered the orthopaedic literature as a concept, but has not been confirmed as a distinct clinical entity. The term is used freely, sometimes as a synonym for flexion instability. However, the terms need to be clearly separated. A cadaver study published in 1990 associated joint line elevation with decreased stability at many angles of flexion, but that model was not typical of clinical scenarios. The literature is considered and it is proposed that the more common entity of an uncorrected flexion contracture after a measured resection arthroplasty technique is more likely to produce clinical findings that suggest instability mid-flexion. It is proposed that the clinical scenario encountered is generalised instability, with the appearance of stability in full extension from tight posterior structures. This paper seeks to clarify whether mid-flexion instability exists as an entity distinct from other commonly recognised forms of instability. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):84–8


Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. Methods. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. Results. Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R. 2. = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R. 2. = 0.352; p = 0.029), and TKA femoral sagittal alignment (R. 2. = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. Conclusion. Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433–443


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 105 - 112
1 Jan 2021
Lynch JT Perriman DM Scarvell JM Pickering MR Galvin CR Neeman T Smith PN

Aims. Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. Methods. In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis. Results. CR-FB designs had significantly lower maximal flexion (mean 116° (SD 2.1°)) compared to CR-RP (123° (SD 1.6°)) and PS-FB (125° (SD 2.1°)). The PS-FB design displayed a more posteriorly positioned femur throughout flexion. Furthermore, the CR-RP femur was more externally rotated throughout kneeling. Finally, individual patient kinematics showed high degrees of variability within all designs. Conclusion. The increased maximal flexion found in the PS-FB and CR-RP designs were likely achieved in different ways. The PS-FB design uses a cam-post to hold the femur more posteriorly preventing posterior impingement. The external rotation within the CR-RP design was surprising and hasn’t previously been reported. It is likely due to the polyethylene bearing being decoupled from flexion. The findings of this study provide insights into the function of different knee arthroplasty designs in the context during deep kneeling and provide clinicians with a more kinematically informed choice for implant selection and may allow improved management of patients' functional expectations. Cite this article: Bone Joint J 2021;103-B(1):105–112


Bone & Joint Open
Vol. 2, Issue 6 | Pages 397 - 404
1 Jun 2021
Begum FA Kayani B Magan AA Chang JS Haddad FS

Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 507 - 514
1 Mar 2021
Chang JS Kayani B Wallace C Haddad FS

Aims. Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology. Methods. This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°). Results. TKA with functional alignment achieved balanced medial and lateral compartment pressures at 10° (25.0 psi (SD 6.1) vs 23.1 psi (SD 6.7), respectively; p = 0.140), 45° (21.4 psi (SD 5.9) vs 20.6 psi (SD 5.9), respectively; p = 0.510), and 90° (21.2 psi (SD 7.1) vs 21.6 psi (SD 9.0), respectively; p = 0.800) of knee flexion. Mean ICPD was 6.1 psi (SD 4.5; 0 to 14) at 10°, 5.4 psi (SD 3.9; 0 to 12) at 45°, and 4.9 psi (SD 4.45; 0 to 15) at 90° of knee flexion. Mean postoperative limb alignment was 2.2° varus (SD 1.0°). Conclusion. TKA using the functional alignment achieves balanced mediolateral soft-tissue tension through the arc of knee flexion as assessed using intraoperative pressure-sensor technology. Further clinical trials are required to determine if TKA with functional alignment translates to improvements in patient satisfaction and outcomes compared to conventional alignment techniques. Cite this article: Bone Joint J 2021;103-B(3):507–514


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims. The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients. Methods. All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m. 2. (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle). Results. The FBow impact on the mMDFA can be measured by the C’KS angle. The C’KS angle took the localization (length DK) and the importance (FBow angle) of the FBow into consideration. The mean FBow angle was 4.4° (SD 2.4; 0 to 12.5). The mean C’KS angle was 1.8° (SD 1.1; 0 to 5.8). Overall, 84 knees (41%) had a severe FBow (> 5°). The radiological measurements showed very good to excellent intraobserver and interobserver agreements. The C’KS increased significantly when the length DK decreased and the FBow angle increased (p < 0.001). Conclusion. The impact of the diaphyseal femoral deformity on the mechanical femoral axis is measured by the C’KS angle, a reliable and reproducible measurement. Cite this article: Bone Jt Open 2023;4(4):262–272


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI), patellar clunk syndrome, and instability. Unaffected limbs were revised in four cases: two for instability and one each for PJI and tibial component loosening. The ten-year survivorship free from any reoperation was 86% (95% CI 75 to 97) and 80% (95% CI 64 to 99) in affected and unaffected limbs, respectively. There were three additional reoperations among affected and two in unaffected limbs. There were 12 nonoperative complications, including four periprosthetic fractures. Arthrofibrosis occurred in five affected (8%) and two unaffected limbs (4%). Postoperative range of motion decreased with 31% achieving less than 90° knee flexion by five years. Conclusion. TKAs in post-polio patients are complex cases associated with instability, and one in four require constraint on the affected side. Periprosthetic fracture was the main mode of failure. Arthrofibrosis rates were high and twice as frequent in affected limbs. Cite this article: Bone Joint J 2023;105-B(6):635–640


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1082 - 1088
1 Dec 2021
Hippalgaonkar K Chandak V Daultani D Mulpur P Eachempati KK Reddy AG

Aims. Single-shot adductor canal block (ACB) after total knee arthroplasty (TKA) for postoperative analgesia is a common modality. Patients can experience breakthrough pain when the effect of ACB wears off. Local anaesthetic infusion through an intra-articular catheter (IAC) can help manage breakthrough pain after TKA. We hypothesized that combined ACB with ropivacaine infusion through IAC is associated with better pain relief compared to ACB used alone. Methods. This study was a prospective double-blinded placebo-controlled randomized controlled trial to compare the efficacy of combined ACB+ IAC-ropivacaine infusion (study group, n = 68) versus single-shot ACB+ intra-articular normal saline placebo (control group, n = 66) after primary TKA. The primary outcome was assessment of pain, using the visual analogue scale (VAS) recorded at 6, 12, 24, and 48 hours after surgery. Secondary outcomes included active knee ROM 48 hours after surgery and additional requirement of analgesia for breakthrough pain. Results. The study group (mean visual analogue scale (VAS) pain score of 5.5 (SD 0.889)) experienced significant reduction in pain 12 hours after surgery compared to the control group (mean VAS 6.62 (SD 1.356); mean difference = 1.12, 95% confidence interval (CI) -1.46 to 0.67; p < 0.001), and pain scores on postoperative day (POD) 1 and POD-2 were lower in the study group compared to the control group (mean difference in VAS pain = 1.04 (-1.39 to -0.68, 95% CI, p < 0.001). Fewer patients in the study group (0 vs 3 in the control group) required additional analgesia for breakthrough pain, but this was not statistically significant. The study group had significantly increased active knee flexion (mean flexion 86.4° (SD 7.22°)), compared to the control group (mean 73.86° (SD 7.88°), mean difference = 12.54, 95% CI 9.97 to 15.1; p < 0.014). Conclusion. Combined ACB+ ropivacaine infusion via IAC is a safe, reproducible analgesic modality after primary TKA, with superior analgesia compared to ACB alone. Further large volume trials are warranted to generate evidence on clinical significance on analgesia after TKA. Cite this article: Bone Jt Open 2021;2(12):1082–1088


Bone & Joint Research
Vol. 9, Issue 9 | Pages 593 - 600
1 Sep 2020
Lee J Koh Y Kim PS Kang KW Kwak YH Kang K

Aims. Unicompartmental knee arthroplasty (UKA) has become a popular method of treating knee localized osteoarthritis (OA). Additionally, the posterior cruciate ligament (PCL) is essential to maintaining the physiological kinematics and functions of the knee joint. Considering these factors, the purpose of this study was to investigate the biomechanical effects on PCL-deficient knees in medial UKA. Methods. Computational simulations of five subject-specific models were performed for intact and PCL-deficient UKA with tibial slopes. Anteroposterior (AP) kinematics and contact stresses of the patellofemoral (PF) joint and the articular cartilage were evaluated under the deep-knee-bend condition. Results. As compared to intact UKA, there was no significant difference in AP translation in PCL-deficient UKA with a low flexion angle, but AP translation significantly increased in the PCL-deficient UKA with high flexion angles. Additionally, the increased AP translation became decreased as the posterior tibial slope increased. The contact stress in the PF joint and the articular cartilage significantly increased in the PCL-deficient UKA, as compared to the intact UKA. Additionally, the increased posterior tibial slope resulted in a significant decrease in the contact stress on PF joint but significantly increased the contact stresses on the articular cartilage. Conclusion. Our results showed that the posterior stability for low flexion activities in PCL-deficient UKA remained unaffected; however, the posterior stability for high flexion activities was affected. This indicates that a functional PCL is required to ensure normal stability in UKA. Additionally, posterior stability and PF joint may reduce the overall risk of progressive OA by increasing the posterior tibial slope. However, the excessive posterior tibial slope must be avoided. Cite this article: Bone Joint Res 2020;9(9):593–600


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 442 - 448
1 Apr 2020
Kayani B Konan S Ahmed SS Chang JS Ayuob A Haddad FS

Aims. The objectives of this study were to assess the effect of anterior cruciate ligament (ACL) resection on flexion-extension gaps, mediolateral soft tissue laxity, maximum knee extension, and limb alignment during primary total knee arthroplasty (TKA). Methods. This prospective study included 140 patients with symptomatic knee osteoarthritis undergoing primary robotic-arm assisted TKA. All operative procedures were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess study outcomes pre- and post-ACL resection with knee extension and 90° knee flexion. This study included 76 males (54.3%) and 64 females (45.7%) with a mean age of 64.1 years (SD 6.8) at time of surgery. Mean preoperative hip-knee-ankle deformity was 6.1° varus (SD 4.6° varus). Results. ACL resection increased the mean extension gap significantly more than the flexion gap in the medial (mean 1.2 mm (SD 1.0) versus mean 0.2 mm (SD 0.7) respectively; p < 0.001) and lateral (mean 1.1 mm (SD 0.9) versus mean 0.2 mm (SD 0.6) respectively; p < 0.001) compartments. The mean gap differences following ACL resection did not create any significant mediolateral soft tissue laxity in extension (gap difference: mean 0.1 mm (SD 2.4); p = 0.89) or flexion (gap difference: mean 0.2 mm (SD 3.1); p = 0.40). ACL resection did not significantly affect maximum knee extension (change in maximum knee extension = mean 0.2° (SD 0.7°); p = 0.23) or fixed flexion deformity (mean 4.2° (SD 3.2°) pre-ACL release versus mean 3.9° (SD 3.7°) post-ACL release; p = 0.61). ACL resection did not significantly affect overall limb alignment (change in alignment = mean 0.2° valgus (SD 1.0° valgus; p = 0.11). Conclusion. ACL resection creates flexion-extension mismatch by increasing the extension gap more than the flexion gap. However, gap differences following ACL resection do not create any mediolateral soft tissue laxity in extension or flexion. ACL resection does not affect maximum knee extension or overall limb alignment. Cite this article: Bone Joint J 2020;102-B(4):442–448


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 67 - 73
1 Jun 2021
Lee G Wakelin E Randall A Plaskos C

Aims. Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following total knee arthroplasty (TKA). The aim of this study was to determine whether a surgeon, with robotic assistance, can predict the outcome as assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) for pain (KPS), one year postoperatively, and establish what factors correlate with poor KOOS scores in a well-aligned and balanced TKA. Methods. A total of 134 consecutive patients who underwent TKA using a dynamic ligament tensioning robotic system with a tibia first resection technique and a cruciate sacrificing ultracongruent TKA system were enrolled into a prospective study. Each TKA was graded based on the final mediolateral ligament balance at 10° and 90° of flexion: 1) < 1 mm difference in the thickness of the tibial insert and that which was planned (n = 75); 2) < 1 mm difference (n = 26); 3) between 1 mm to 2 mm difference (n = 26); and 4) > 2 mm difference (n = 7). The mean one-year KPS score for each grade of TKA was compared and the likelihood of achieving an KPS score of > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high-grade TKA (grade A and B) were analyzed. Results. Patients with a grade of A or B TKA had significantly higher mean one-year KPS scores compared with those with C or D grades (p = 0.031). There was no difference in KPS scores in grade A or B TKAs, but 33% of these patients did not have a KPS score of > 90. While there was no correlation with age, sex, preoperative deformity, and preoperative KOOS and Patient-Reported Outcomes Measurement Information System (PROMIS) physical scores, patients with a KPS score of < 90, despite a grade A or B TKA, had lower PROMIS mental health scores compared with those with KPS scores of > 90 (54.1 vs 50.8; p = 0.043). Patients with grade A and B TKAs with KPS > 90 were significantly more likely to respond with “my expectations were too low”, and with “the knee is performing better than expected” compared with patients with these grades of TKA who had a KPS score of < 90 (40% vs 22%; p = 0.004). Conclusion. A TKA balanced with robotic assistance to within 1 mm of difference between the medial and lateral sides in both flexion and extension had a higher KPS score one year postoperatively. Despite accurate ligament balance information, a robotic system could not guarantee excellent pain relief. Patient expectations and mental status also significantly affected the perceived success of TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):67–73


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1230 - 1237
1 Oct 2019
Kayani B Konan S Horriat S Ibrahim MS Haddad FS

Aims. The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA). Patients and Methods. This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (. sd. 6.2) at the time of surgery. The mean preoperative hip-knee-ankle deformity was 4.1° varus (. sd. 3.4). Results. PCL resection increased the mean flexion gap significantly more than the extension gap in the medial (2.4 mm (. sd. 1.5) vs 1.3 mm (. sd. 1.0); p < 0.001) and lateral (3.3 mm (. sd. 1.6) vs 1.2 mm (. sd. 0.9); p < 0.01) compartments. The mean gap differences after PCL resection created significant mediolateral laxity in flexion (gap difference: 1.1 mm (. sd. 2.5); p < 0.001) but not in extension (gap difference: 0.1 mm (. sd. 2.1); p = 0.51). PCL resection significantly improved the mean FFD (6.3° (. sd. 4.4) preoperatively vs 3.1° (. sd. 1.5) postoperatively; p < 0.001). There was a strong positive correlation between the preoperative FFD and change in FFD following PCL resection (Pearson’s correlation coefficient = 0.81; p < 0.001). PCL resection did not significantly affect limb alignment (mean change in alignment: 0.2° valgus (. sd. 1.2); p = 0.60). Conclusion. PCL resection creates flexion-extension mismatch by increasing the flexion gap more than the extension gap. The increase in the lateral flexion gap is greater than the increase in the medial flexion gap, which creates mediolateral laxity in flexion. Improvements in FFD following PCL resection are dependent on the degree of deformity before PCL resection. Cite this article: Bone Joint J 2019;101-B:1230–1237


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims. The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). Methods. A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other. Results. Of 50 knees (10%) with no soft tissue releases (other than cruciate ligaments), 90% were aligned, 81% were balanced, and 73% were aligned and balanced. In 288 knees (59%) only osteophyte excision was performed by subperiosteally releasing the deep medial collateral ligament. Of these, 98% were aligned, 80% were balanced, and 79% were aligned and balanced. In 154 knees (31%), additional procedures were performed (reduction osteotomy, posterior capsular release, and semimembranosus release). Of these, 89% were aligned, 68% were balanced, and 66% were aligned and balanced. The superficial medial collateral ligament was not released in any case. Conclusion. Two-thirds of all knees could be aligned and balanced with release of the cruciate ligaments alone and excision of osteophytes. Excision of osteophytes can be a useful step towards achieving deformity correction and gap balance without having to resort to soft tissue release in varus knees while maintaining classical coronal and sagittal alignment of components. Cite this article: Bone Joint J 2020;102-B(6 Supple A):49–58


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims. The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?. Patients and Methods. A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS). Results. Postoperative limb alignment did not affect outcomes. The standing hip-knee-ankle (HKA) angle was the sole positive predictor of the joint line convergence angle (JLCA) (p < 0.001). Increasing lateral flexion gap laxity was consistently associated with better outcomes. Lateral flexion gap laxity did not correlate with HKA angle, the JLCA, or lateral extension gap laxity. Minor releases were required in one third of cases. Conclusion. The standing HKA angle is the primary determinant of the JLCA in KTKA. A rectangular flexion gap is produced in only 11% of cases. Lateral flexion gap laxity is consistently associated with better outcomes and does not affect balance in extension. Minor releases are sometimes required as well, particularly in limbs with larger preoperative deformities. Cite this article: Bone Joint J 2019;101-B:331–339


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 126 - 130
1 Jun 2021
Chalmers BP Goytizolo E Mishu MD Westrich GH

Aims. Manipulation under anaesthesia (MUA) remains an effective intervention to address restricted range of motion (ROM) after total knee arthroplasty (TKA) and occurs in 2% to 3% of primary TKAs at our institution. Since there are few data on the outcomes of MUA with different anaesthetic methods, we sought to compare the outcomes of patients undergoing MUA with intravenous (IV) sedation and neuraxial anaesthesia. Methods. We identified 548 MUAs after primary TKA (136 IV sedation, 412 neuraxial anaesthesia plus IV sedation) from March 2016 to July 2019. The mean age of this cohort was 62 years (35 to 88) with a mean body mass index of 31 kg/m. 2. (18 to 49). The mean time from primary TKA to MUA was 10.2 weeks (6.2 to 24.3). Pre-MUA ROM was similar between groups; overall mean pre-MUA extension was 4.2° (p = 0.452) and mean pre-MUA flexion was 77° (p = 0.372). We compared orthopaedic complications, visual analogue scale (VAS) pain scores, length of stay (LOS), and immediate and three-month follow-up knee ROM between these groups. Results. Following MUA, patients with IV sedation had higher mean VAS pain scores of 5.2 (SD 1.8) compared to 4.1 (SD = 1.5) in the neuraxial group (p < 0.001). The mean LOS was shorter in patients that received IV sedation (9.5 hours (4 to 31)) compared to neuraxial anaesthesia (11.9 hours (4 to 51)) (p = 0.009), but an unexpected overnight stay was similar in each group (8.6%). Immediate-post MUA ROM was 1° to 121° in the IV sedation group and 0.9° to 123° in the neuraxial group (p = 0.313). Three-month follow-up ROM was 2° to 108° in the IV sedation group and 1.9° to 110° in the neuraxial anaesthesia group (p = 0.325) with a mean loss of 13° (ranging from 5° gain to 60° loss), in both groups by three months. No patients in either group sustained a complication. Conclusion. IV sedation alone and neuraxial anaesthesia are both effective anaesthetic methods for MUA after primary TKA. Surgeons and anaesthetists should offer these anaesthetic techniques to match patient-specific needs as the orthopaedic outcomes are similar. Also, patients should be counselled that ROM following MUA may decrease over time. Cite this article: Bone Joint J 2021;103-B(6 Supple A):126–130


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 59 - 65
1 Jun 2020
Kwon Y Arauz P Peng Y Klemt C

Aims. The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as a potential contributing factor to patient dissatisfaction, due to alteration of the in vivo biomechanics of the knee. Bicruciate retaining (BCR) TKA allows the preservation of the cruciate ligaments, thus offering the potential to reproduce healthy kinematics. The aim of this study was to compare in vivo kinematics between the operated and contralateral knee in patients who have undergone TKA with a contemporary BCR design. Methods. A total of 29 patients who underwent unilateral BCR TKA were evaluated during single-leg deep lunges and sit-to-stand tests using a validated computer tomography and fluoroscopic imaging system. In vivo six-degrees of freedom (6DOF) kinematics were compared between the BCR TKA and the contralateral knee. Results. During single-leg deep lunge, BCR TKAs showed significantly less mean posterior femoral translation (13 mm; standard deviation (SD) 4) during terminal flexion, compared with the contralateral knee (16.6 mm, SD 3.7; p = 0.001). Similarly, BCR TKAs showed significantly less mean femoral rollback (11.6 mm (SD 4.5) vs 14.4 mm (SD 4.6); p < 0.043) during sit-to-stand. BCR TKAs showed significantly reduced internal rotation during many parts of the strenuous flexion activities particularly during high-flexion lunge (4° (SD 5.6°) vs 6.5° (SD 6.1°); p = 0.051) and during sit-to-stand (4.5° (SD 6°) vs 6.9° (SD 6.3°); p = 0.048). Conclusion. The contemporary design of BCR TKA showed asymmetrical flexion-extension and internal-external rotation, suggesting that the kinematics are not entirely reproduced during strenuous activities. Future studies are required to establish the importance of patient factors, component orientation and design, in optimizing kinematics in patients who undergo BCR TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):59–65


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1585 - 1591
1 Dec 2018
Kaneko T Kono N Mochizuki Y Hada M Sunakawa T Ikegami H Musha Y

Aims. Patellofemoral problems are a common complication of total knee arthroplasty. A high compressive force across the patellofemoral joint may affect patient-reported outcome. However, the relationship between patient-reported outcome and the intraoperative patellofemoral contact force has not been investigated. The purpose of this study was to determine whether or not a high intraoperative patellofemoral compressive force affects patient-reported outcome. Patients and Methods. This prospective study included 42 patients (42 knees) with varus-type osteoarthritis who underwent a bi-cruciate stabilized total knee arthroplasty and in whom the planned alignment was confirmed on 3D CT. Of the 42 patients, 36 were women and six were men. Their mean age was 72.3 years (61 to 87) and their mean body mass index (BMI) was 24.4 kg/m2 (18.2 to 34.3). After implantation of the femoral and tibial components, the compressive force across the patellofemoral joint was measured at 10°, 30°, 60°, 90°, 120°, and 140° of flexion using a load cell (Kyowa Electronic Instruments Co., Ltd., Tokyo, Japan) manufactured in the same shape as the patellar implant. Multiple regression analyses were conducted to investigate the relationship between intraoperative patellofemoral compressive force and patient-reported outcome two years after implantation. Results. No patient had anterior knee pain after total knee arthroplasty. The compressive force across the patellofemoral joint at 140°of flexion was negatively correlated with patient satisfaction (R2 = 0.458; β = –0.706; p = 0. 041) and Forgotten Joint Score-12 (FJS-12; R2= .378; β = –0.636; p = 0. 036). The compressive force across the patellofemoral joint at 60° of flexion was negatively correlated with the patella score (R2 = 0.417; β = –0.688; p = 0. 046). Conclusion. Patient satisfaction, FJS-12, and patella score were affected by the patellofemoral compressive force at 60° and 140° of flexion. Reduction of the patellofemoral compressive forces at 60° and 140° of flexion angle during total knee arthroplasty may improve patient-reported outcome, but has no effect on anterior knee pain


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 3 - 12
1 Jun 2021
Crawford DA Duwelius PJ Sneller MA Morris MJ Hurst JM Berend KR Lombardi AV

Aims. The purpose is to determine the non-inferiority of a smartphone-based exercise educational care management system after primary knee arthroplasty compared with a traditional in-person physiotherapy rehabilitation model. Methods. A multicentre prospective randomized controlled trial was conducted evaluating the use of a smartphone-based care management system for primary total knee arthroplasty (TKA) and partial knee arthroplasty (PKA). Patients in the control group (n = 244) received the respective institution’s standard of care with formal physiotherapy. The treatment group (n = 208) were provided a smartwatch and smartphone application. Early outcomes assessed included 90-day knee range of movement, EuroQoL five-dimension five-level score, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) score, 30-day single leg stance (SLS) time, Time up and Go (TUG) time, and need for manipulation under anaesthesia (MUA). Results. Overall, 90-day mean flexion was not significantly different between the control (121° (SD 11.7°)) and treatment groups (121. o. ; p = 0.559); 90-day mean SLS was 22.7 seconds (SD 9.8) in controls and 24.3 seconds (SD 20.8) in treatment (p = 0.519); 90-day mean TUG times were 10.1 seconds (SD 4.8) in control and 9.3 seconds (SD 3.3) in treatment (p = 0.139). Mean KOOS JR scores were significantly different between control group (73.6 (SD 13.4)) and treatment group (70.4 (SD 12.6); p = 0.026). MUAs were performed in nine (3.7%) patients in the control group and four (1.9%) in the treatment group (p = 0.398). Physiotherapy was performed by 230 (94.4%) of control group and 123 (59.3%) of treatment group (p < 0.001). There were no significant differences between groups in postoperative urgent care visits, or readmissions within 90 days, with significantly fewer emergency department visits in the treatment group (16 (8.2%) vs five (2.5%), p = 0.014). Conclusion. The use of the smartwatch/smartphone care platform demonstrated non-inferiority of clinically significant outcomes to traditional care models, while requiring significantly less postoperative physiotherapy and fewer emergency department visits. This platform could aid in decreasing postoperative costs, while improving patient engagement and communication with the healthcare team. Cite this article: Bone Joint J 2021;103-B(6 Supple A):3–12


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 191 - 195
1 Jun 2021
Gausden EB Shirley MB Abdel MP Sierra RJ

Aims. To describe the risk of periprosthetic joint infection (PJI) and reoperation in patients who have an acute, traumatic wound dehiscence following total knee arthroplasty (TKA). Methods. From January 2002 to December 2018, 16,134 primary TKAs were performed at a single institution. A total of 26 patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68 years (44 to 87), 38% (n = 10) were female, and mean BMI was 34 kg/m. 2. (23 to 48). Median time to dehiscence was 13 days (interquartile range (IQR) 4 to 15). The dehiscence resulted from a fall in 22 patients and sudden flexion after staple removal in four. The arthrotomy was also disrupted in 58% (n = 15), including a complete extensor mechanism disruption in four knees. An irrigation and debridement with component retention (IDCR) was performed within 48 hours in 19 of 26 knees and two-thirds were discharged on antibiotic therapy. The mean follow-up was six years (2 to 15). The association of wound dehiscence and the risk of developing a PJI was analyzed. Results. Patients who sustained a traumatic wound dehiscence had a 6.5-fold increase in the risk of PJI (95% confidence interval (CI) 1.6 to 26.2; p = 0.008). With the small number of PJIs, no variables were found to be significant risk factors. However, there were no PJIs in any of the patients who were treated with IDCR and a course of antibiotics. Three knees required reoperation including one two-stage exchange for PJI, one repeat IDCR for PJI, and one revision for aseptic loosening of the tibial component. Conclusion. Despite having a traumatic wound dehiscence, the risk of PJI was low, but much higher than experienced in all other TKAs during the same period. We recommend urgent IDCR and a course of postoperative antibiotics to decrease the risk of PJI. A traumatic wound dehiscence increases risk of PJI by 6.5-fold. Cite this article: Bone Joint J 2021;103-B(6 Supple A):191–195


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 329 - 337
1 Feb 2021
MacDessi SJ Griffiths-Jones W Harris IA Bellemans J Chen DB

Aims. A comprehensive classification for coronal lower limb alignment with predictive capabilities for knee balance would be beneficial in total knee arthroplasty (TKA). This paper describes the Coronal Plane Alignment of the Knee (CPAK) classification and examines its utility in preoperative soft tissue balance prediction, comparing kinematic alignment (KA) to mechanical alignment (MA). Methods. A radiological analysis of 500 healthy and 500 osteoarthritic (OA) knees was used to assess the applicability of the CPAK classification. CPAK comprises nine phenotypes based on the arithmetic HKA (aHKA) that estimates constitutional limb alignment and joint line obliquity (JLO). Intraoperative balance was compared within each phenotype in a cohort of 138 computer-assisted TKAs randomized to KA or MA. Primary outcomes included descriptive analyses of healthy and OA groups per CPAK type, and comparison of balance at 10° of flexion within each type. Secondary outcomes assessed balance at 45° and 90° and bone recuts required to achieve final knee balance within each CPAK type. Results. There was similar frequency distribution between healthy and arthritic groups across all CPAK types. The most common categories were Type II (39.2% healthy vs 32.2% OA), Type I (26.4% healthy vs 19.4% OA) and Type V (15.4% healthy vs 14.6% OA). CPAK Types VII, VIII, and IX were rare in both populations. Across all CPAK types, a greater proportion of KA TKAs achieved optimal balance compared to MA. This effect was largest, and statistically significant, in CPAK Types I (100% KA vs 15% MA; p < 0.001), Type II (78% KA vs 46% MA; p = 0.018). and Type IV (89% KA vs 0% MA; p < 0.001). Conclusion. CPAK is a pragmatic, comprehensive classification for coronal knee alignment, based on constitutional alignment and JLO, that can be used in healthy and arthritic knees. CPAK identifies which knee phenotypes may benefit most from KA when optimization of soft tissue balance is prioritized. Further, it will allow for consistency of reporting in future studies. Cite this article: Bone Joint J 2021;103-B(2):329–337


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 552 - 558
1 May 2019
Clark D Stevens JM Tortonese D Whitehouse MR Simpson D Eldridge J

Aims. The aim of this study was to determine and compare the congruency of the articular surface contact area of the patellofemoral joint (PFJ) during both active and passive movement of the knee with the use of an MRI mapping technique in both the stable and unstable PFJ. Patients and Methods. A prospective case-control MRI imaging study of patients with a history of PFJ instability and a control group of volunteers without knee symptoms was performed. The PFJs were imaged with the use of an MRI scan during both passive and active movement from 0° through to 40° of flexion. The congruency through measurement of the contact surface area was mapped in 5-mm intervals on axial slices. In all, 40 patients were studied. The case group included 31 patients with symptomatic patellofemoral instability and the control group of nine asymptomatic volunteers. The ages were well matched between the case and control groups. The mean age was 25 years (16 to 42; . sd. 6.9) in the case group and 26 years (19 to 32; . sd. 5.1) in the control group. There were 19 female and 12 male patients in the case group. Results. The unstable PFJs were demonstrably less congruent than the stable PFJs throughout the range of knee movement. The greatest mean differences in congruency between unstable and stable PFJ’s were observed between 11° and 20° flexion (1.73 cm. 2. vs 4.00 cm. 2. ; p < 0.005). . Conclusion. The unstable PFJ is less congruent than the stable PFJ throughout the range of knee movement studied. This approach to mapping PFJ congruency produces a measurable outcome and will allow the assessment of pre- and postoperative results following surgical intervention. This may facilitate the design of new procedures for patients with PFJ instability. If a single axial series is to be obtained on MRI scan, the authors recommend 11° to 20° of tibiofemoral flexion, as this was shown to have the greatest difference in contact surface area between the case and control groups. Cite this article: Bone Joint J 2019;101-B:552–558


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 117 - 124
1 Jan 2020
MacDessi SJ Griffiths-Jones W Chen DB Griffiths-Jones S Wood JA Diwan AD Harris IA

Aims. It is unknown whether kinematic alignment (KA) objectively improves knee balance in total knee arthroplasty (TKA), despite this being the biomechanical rationale for its use. This study aimed to determine whether restoring the constitutional alignment using a restrictive KA protocol resulted in better quantitative knee balance than mechanical alignment (MA). Methods. We conducted a randomized superiority trial comparing patients undergoing TKA assigned to KA within a restrictive safe zone or MA. Optimal knee balance was defined as an intercompartmental pressure difference (ICPD) of 15 psi or less using a pressure sensor. The primary endpoint was the mean intraoperative ICPD at 10° of flexion prior to knee balancing. Secondary outcomes included balance at 45° and 90°, requirements for balancing procedures, and presence of tibiofemoral lift-off. Results. A total of 63 patients (70 knees) were randomized to KA and 62 patients (68 knees) to MA. Mean ICPD at 10° flexion in the KA group was 11.7 psi (SD 13.1) compared with 32.0 psi in the MA group (SD 28.9), with a mean difference in ICPD between KA and MA of 20.3 psi (p < 0.001). Mean ICPD in the KA group was significantly lower than in the MA group at 45° and 90°, respectively (25.2 psi MA vs 14.8 psi KA, p = 0.004; 19.1 psi MA vs 11.7 psi KA, p < 0.002, respectively). Overall, participants in the KA group were more likely to achieve optimal knee balance (80% vs 35%; p < 0.001). Bone recuts to achieve knee balance were more likely to be required in the MA group (49% vs 9%; p < 0.001). More participants in the MA group had tibiofemoral lift-off (43% vs 13%; p < 0.001). Conclusion. This study provides persuasive evidence that restoring the constitutional alignment with KA in TKA results in a statistically significant improvement in quantitative knee balance, and further supports this technique as a viable alternative to MA. Cite this article: Bone Joint J. 2020;102-B(1):117–124