Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Bone & Joint Open
Vol. 1, Issue 9 | Pages 520 - 529
1 Sep 2020
Mackay ND Wilding CP Langley CR Young J

Aims

COVID-19 represents one of the greatest global healthcare challenges in a generation. Orthopaedic departments within the UK have shifted care to manage trauma in ways that minimize exposure to COVID-19. As the incidence of COVID-19 decreases, we explore the impact and risk factors of COVID-19 on patient outcomes within our department.

Methods

We retrospectively included all patients who underwent a trauma or urgent orthopaedic procedure from 23 March to 23 April 2020. Electronic records were reviewed for COVID-19 swab results and mortality, and patients were screened by telephone a minimum 14 days postoperatively for symptoms of COVID-19.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims

Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences.

Methods

A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 541 - 548
8 Sep 2020
MacDonald DRW Neilly DW Davies PSE Crome CR Jamal B Gill SL Jariwala AC Stevenson IM Ashcroft GP

Aims

The UK government declared a national lockdown on 23 March 2020 to reduce transmission of COVID-19. This study aims to identify the effect of lockdown on the rates, types, mechanisms, and mortality of musculoskeletal trauma across Scotland.

Methods

Data for all musculoskeletal trauma requiring operative treatment were collected prospectively from five key orthopaedic units across Scotland during lockdown (23 March 2020 to 28 May 2020). This was compared with data for the same timeframe in 2019 and 2018. Data collected included all cases requiring surgery, injury type, mechanism of injury, and inpatient mortality.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 107 - 110
1 Jan 2006
Watts AC Howie CR Simpson AHRW

The risk of venous thromboembolism in patients following arthroplasty may be reduced by continuing chemical thromboprophylaxis for up to 35 days post-operatively. This prospective cohort study investigated the compliance of 40 consecutive consenting patients undergoing lower limb arthroplasty with self-administration of a recommended subcutaneous chemotherapeutic agent for six weeks after surgery. Compliance was assessed by examination of the patient for signs of injection, number of syringes used, and a self-report diary at the end of the six-week period. A total of 40 patients, 15 men and 25 women, were recruited. One woman was excluded because immediate post-operative complications prevented her participation. Self-administration was considered feasible in 87% of patients (95% confidence interval (CI) 76 to 98) at the time of discharge. Among this group of 34 patients, 29 (85%) were compliant (95% CI 73 to 97). Patients can learn to self-administer subcutaneous injections of thromboprophylaxis, and compliance with extended prophylaxis to six weeks is good.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims

The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices.

Methods

We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.


Bone & Joint Research
Vol. 4, Issue 6 | Pages 99 - 104
1 Jun 2015
Savaridas T Wallace RJ Dawson S Simpson AHRW

Objectives

There remains conflicting evidence regarding cortical bone strength following bisphosphonate therapy. As part of a study to assess the effects of bisphosphonate treatment on the healing of rat tibial fractures, the mechanical properties and radiological density of the uninjured contralateral tibia was assessed.

Methods

Skeletally mature aged rats were used. A total of 14 rats received 1µg/kg ibandronate (iban) daily and 17 rats received 1 ml 0.9% sodium chloride (control) daily. Stress at failure and toughness of the tibial diaphysis were calculated following four-point bending tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery.