Advertisement for orthosearch.org.uk
Results 1 - 50 of 55
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims. To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Methods. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC). Results. Angle U showed the strongest correlation with CTa (p < 0.001). In the analysis of inter- and intraobserver reliability, Kappa values were significantly higher for Angles S and U compared with Angle P. ICC values were excellent among the three groups. Conclusion. Angle U on AP view was the best substitute for CTa when evaluating radial neck fractures in children. Further studies are required to validate this method. Cite this article: Bone Joint J 2024;106-B(9):964–969


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1629 - 1635
1 Dec 2020
Wang Q Sheng N Rui B Chen Y

Aims. The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error. Methods. We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model. Results. Data from 203 patients (63 males and 140 females) with a mean age of 62 years (22 to 89) were analyzed. In 49 fractures, the calcar screw was considered to be malpositioned; in 154 it was in the optimal position. The rate of malpositioning was therefore 24% (49/203). No preoperative risk factor was found for malpositioning of the calcar screws. Only the neck-shaft angle was found to be related to the risk of screw malpositioning in a multivariate model (with an AUC of 0.72). For the fractures in which the neck-shaft angle was reduced to between 130° and 150°, 91% (133/46) of calcar screws were in the optimal position. Conclusion. The neck-shaft angle is the key factor for the appropriate positioning of calcar screws when treating a proximal humeral fracture with a locking plate. We recommend reducing the angle to between 130° and 150°. Cite this article: Bone Joint J 2020;102-B(12):1629–1635


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives. To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies. Methods. 3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction. Results. CSA did not seem to influence ROM in any of the models, but greater lateralization achieved greater ROM for all movements in all configurations. Internal and external rotation at 90° of abduction were impossible in most configurations, except in models with a CSA of 25°. Conclusion. Postoperative ROM following RSA depends on multiple patient and surgical factors. This study, based on computer simulation, suggests that CSA has no influence on ROM after RSA, while lateralization increases ROM in all configurations. Furthermore, increasing subacromial space is important to grant sufficient rotation at 90° of abduction. In summary, increased lateralization of the COR and increased subacromial space improve ROM in all CSA configurations. Cite this article: A. Lädermann, E. Tay, P. Collin, S. Piotton, C-H Chiu, A. Michelet, C. Charbonnier. Effect of critical shoulder angle, glenoid lateralization, and humeral inclination on range of movement in reverse shoulder arthroplasty. Bone Joint Res 2019;8:378–386. DOI: 10.1302/2046-3758.88.BJR-2018-0293.R1


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article: Bone Jt Open 2024;5(10):818–824


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom. Results. The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly. Conclusion. The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA. Cite this article: Bone Joint J 2024;106-B(10):1165–1175


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims. Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. Methods. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up. Results. Median postoperative inclination for each group was found to be -3.6° (interquartile range (IQR) -2.1 to -6.9) and 6.0° (3.2° to 10.1°) for the neutrally/inferiorly and superiorly inclined cohorts, respectively. Preoperative inclination was highly associated with postoperative inclination (p = 0.004). When comparing superiorly and neutrally/inferiorly inclined glenospheres, there were no differences in heterotopic ossification (p = 0.606), scapular notching (p = 0.367), American Shoulder and Elbow Surgeons score (p = 0.419), Single Assessment Numeric Evaluation (p = 0.417), Visual Analogue Scale (VAS) pain score (p = 0.290), forward elevation (p = 0.161), external rotation (p = 0.537), or internal rotation (p = 0.656). Conclusion. Compared to neutral and inferior inclination, up to 6° ± 3° of superior glenoid baseplate inclination on a lateralized RSA design produces no differences in postoperative ROM or patient-reported outcomes, and produces similar levels of scapular notching and heterotopic ossification. Additionally, the degree of preoperative inclination represents an important factor in surgical decision-making as it is strongly associated with postoperative inclination. It is important to note that the findings of this study are only reflective of lateralized RSA prostheses. Cite this article: Bone Joint J 2021;103-B(2):360–365


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1133 - 1140
1 Oct 2024
Olsen Kipp J Petersen ET Falstie-Jensen T Frost Teilmann J Zejden A Jellesen Åberg R de Raedt S Thillemann TM Stilling M

Aims

This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.

Methods

A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 478 - 489
1 Jul 2023
Tennent D Antonios T Arnander M Ejindu V Papadakos N Rastogi A Pearse Y

Aims

Glenoid bone loss is a significant problem in the management of shoulder instability. The threshold at which the bone loss is considered “critical” requiring bony reconstruction has steadily dropped and is now approximately 15%. This necessitates accurate measurement in order that the correct operation is performed. CT scanning is the most commonly used modality and there are a number of techniques described to measure the bone loss however few have been validated. The aim of this study was to assess the accuracy of the most commonly used techniques for measuring glenoid bone loss on CT.

Methods

Anatomically accurate models with known glenoid diameter and degree of bone loss were used to determine the mathematical and statistical accuracy of six of the most commonly described techniques (relative diameter, linear ipsilateral circle of best fit (COBF), linear contralateral COBF, Pico, Sugaya, and circle line methods). The models were prepared at 13.8%, 17.6%, and 22.9% bone loss. Sequential CT scans were taken and randomized. Blinded reviewers made repeated measurements using the different techniques with a threshold for theoretical bone grafting set at 15%.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 463 - 469
7 Jun 2022
Vetter P Magosch P Habermeyer P

Aims

The aim of this study was to determine whether there is a correlation between the grade of humeral osteoarthritis (OA) and the severity of glenoid morphology according to Walch. We hypothesized that there would be a correlation.

Methods

Overal, 143 shoulders in 135 patients (73 females, 62 males) undergoing shoulder arthroplasty surgery for primary glenohumeral OA were included consecutively. Mean age was 69.3 years (47 to 85). Humeral head (HH), osteophyte length (OL), and morphology (transverse decentering of the apex, transverse, or coronal asphericity) on radiographs were correlated to the glenoid morphology according to Walch (A1, A2, B1, B2, B3), glenoid retroversion, and humeral subluxation on CT images.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1114 - 1120
1 Aug 2013
Wijdicks CA Anavian J Hill BW Armitage BM Vang S Cole PA

The glenopolar angle assesses the rotational alignment of the glenoid and may provide prognostic information and aid the management of scapula fractures. We have analysed the effect of the anteroposterior (AP) shoulder radiograph rotational offset on the glenopolar angle in a laboratory setting and used this to assess the accuracy of shoulder imaging employed in routine clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae tagged with 2 mm steel spheres to determine the orientation of true AP views. The glenopolar angle was measured on all the bony specimens rotated at 10° increments. The mean glenopolar angle measured on the bone specimens in rotations between 0° and 20° and thereafter was found to be significantly different (p < 0.001). We also obtained the AP radiographs of the uninjured shoulder of 30 patients treated for fractures at our centre and found that none fitted the criteria of a true AP shoulder radiograph. The mean angular offset from the true AP view was 38° (10° to 65°) for this cohort. Radiological AP shoulder views may not fully project the normal anatomy of the scapular body and the measured glenopolar angle. The absence of a true AP view may compromise the clinical management of a scapular fracture. Cite this article: Bone Joint J 2013;95-B:1114–20


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1510 - 1516
1 Nov 2016
Suter T Henninger HB Zhang Y Wylie JD Tashjian RZ

Aims. The aim of this study was to analyse the effect of altered viewing perspectives on the measurement of the glenopolar angle (GPA) and the differences between these measurements made on 3D CT reconstructions and anteroposterior (AP) scapular view radiographs. . Materials and Methods. The influence of the viewing perspective on the GPA was assessed, as were the differences in the measurements of the GPA between 3D CT reconstructions and AP scapular view radiographs in 68 cadaveric scapulae. Results. The median GPA in 3D reconstructions and AP scapular views were 42.7° (95% confidence intervals (CI), 42.0° to 43.5°) and 41.3° (95% CI 40.4° to 42.0°) respectively (p < 0.001). All but five of 20 malpositions demonstrated a significant difference in GPA compared with the respective AP scapular view (p ≤ 0.005). The GPA was most susceptible to malposition in retroversion/anteversion. Inter- and intra-observer reliability for all measurements of the GPA was excellent for 3D CT reconstructions (intraclass correlation (ICC) 0.93 (95% CI 0.87 to 0.96) and 0.94 (95% CI 0.89 to 0.97), respectively) and higher than on AP scapular radiographs (p < 0.001). The intra- and inter-observer reliability was excellent in AP scapular views and malpositions in extension/flexion (ICC ≥ 0.84) but tended to decrease with increasing viewing angle in retroversion/anteversion. Conclusion. These data suggest that 3D reconstructions are more reproducible than AP scapular radiographs in the assessment of the GPA and should be used to compare data in different studies, to predict outcome, define malunion, and act as an indication for surgery in patients with a scapular fracture. Cite this article: Bone Joint J 2016;98-B:1510–16


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 958 - 963
3 May 2021
Nguyen NTV Martinez-Catalan N Songy CE Sanchez-Sotelo J

Aims

The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively.

Methods

A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims. The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint. Patients and Methods. A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, . sd. 0.5; T2, mean 5.3 years,. sd. 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features). Results. The mean Constant score improved significantly from 28.5 (. sd. 11.6) preoperatively to 75.5 (. sd. 8.5) at T1 (p < 0.001) and remained stable over time (T2: 76.6, . sd. 10.2). No stem loosening was seen. High bone adaptation was present in 42% of shoulders at T1, with a slight decrease to 37% at T2. Cortical bone narrowing and osteopenia in the region of the calcar decreased from 76% to 66% between T1 and T2. Patients with high bone adaptation had a significantly higher mean filling ratio of the stem at the metaphysis (0.60, . sd. 0.05 vs 0.55, . sd. 0.06; p = 0.003) and at the diaphysis (0.65 . sd. 0.05 vs 0.60 . sd. 0.05; p = 0.007). Cortical contact of the stem was also associated with high bone adaptation (14/25 shoulders, p = 0.001). The clinical outcome was not influenced by the radiological changes. Conclusion. Total shoulder arthroplasty using a short-stem humeral component resulted in good clinical outcomes with no evidence of loosening. However, approximately 40% of the shoulders developed substantial bone loss in the proximal humerus at between four and seven years of follow-up. Cite this article: Bone Joint J 2018;100-B:603–9


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 951 - 957
1 May 2021
Ng N Nicholson JA Chen P Yapp LZ Gaston MS Robinson CM

Aims

The aim of this study was to define the complications and long-term outcome following adolescent mid-shaft clavicular fracture.

Methods

We retrospectively reviewed a consecutive series of 677 adolescent fractures in 671 patients presenting to our region (age 13 to 17 years) over a ten-year period (2009 to 2019). Long-term patient-reported outcomes (abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score and EuroQol five-dimension three-level (EQ-5D-3L) quality of life score) were undertaken at a mean of 6.4 years (1.2 to 11.3) following injury in severely displaced mid-shaft fractures (Edinburgh 2B) and angulated mid-shaft fractures (Edinburgh 2A2) at a minimum of one year post-injury. The median patient age was 14.8 years (interquartile range (IQR) 14.0 to 15.7) and 89% were male (n = 594/671).


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1521 - 1525
1 Nov 2016
Su Y Nan G

Aims. Cubitus varus is the most common late complication of a supracondylar fracture of the humerus in children. Correction can be performed using one of a number of techniques of osteotomy but each has disadvantages. We describe a new technique for correcting post-traumatic cubitus varus using a lateral closing wedge isosceles triangular osteotomy. Patients and Methods. A lateral closing wedge isosceles triangular osteotomy was performed in 25 patients (15 male and ten female with a mean age of 9.5 years (6 to 12)) between May 2010 and April 2013. All patients had cubitus varus secondary to malunion of a supracondylar fracture, with good function of the elbow and a full range of movement. The osteotomy lines were marked on the bone with an isosceles triangular template made before surgery, after which the osteotomy was performed leaving the medial cortex intact. Fixation was performed using two lateral 2 mm Kirschner (K)-wires and patients were immobilised in an above-elbow plaster. By six to eight weeks callus was present and the wires and cast were removed. Patients were reviewed at four and six weeks, three, six and 12 months and then every two years until skeletal maturity. Clinical and radiographic outcomes were categorised as excellent, good or poor. Results. A total of 23 patients had an excellent and two had a good outcome at a mean final follow-up of 3.4 years (two to four). The mean post-operative carrying angle in the corrected elbow was 11.7° (7° to 18°). One patient fell, displacing the osteotomy, and needed revision of the fixation. No patient had a nerve injury. Conclusion. A lateral isosceles triangular osteotomy and with K-wire fixation is a practical, effective, reliable, safe and simple method of correcting post-traumatic cubitus varus in children. It has inherent stability and excellent cosmesis without prominence of the lateral condyle. . Cite this article: Bone Joint J 2016;98-B:1521–5


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims

The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws.

Methods

Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension.


Objectives. This investigation sought to advance the work published in our prior biomechanical study (Journal of Orthopaedic Research, 2016). We specifically sought to determine whether there are additional easy-to-measure parameters on plain radiographs of the proximal humerus that correlate more strongly with ultimate fracture load, and whether a parameter resembling the Dorr strength/quality characterisation of proximal femurs can be applied to humeri. Materials and Methods. A total of 33 adult humeri were used from a previous study where we quantified bone mineral density of the proximal humerus using radiographs and dual-energy x-ray absorptiometry (DEXA), and regional mean cortical thickness and cortical index using radiographs. The bones were fractured in a simulated backwards fall with the humeral head loaded at 2 mm/second via a frustum angled at 30° from the long axis of the bone. Correlations were assessed with ultimate fracture load and these new parameters: cortical index expressed in areas (“areal cortical index”) of larger regions of the diaphysis; the canal-to-calcar ratio used analogous to its application in proximal femurs; and the recently described medial cortical ratio. Results. The three new parameters showed the following correlations with ultimate fracture load: areal cortical index (r = 0.56, p < 0.001); canal-to-calcar ratio (r = 0.38, p = 0.03); and medial cortical ratio (r = 0.49, p < 0.005). These correlations were weaker when compared with those that we previously reported: mean cortical thickness of the proximal diaphysis versus ultimate fracture load (r = 0.71; p < 0.001); and mean density in the central humeral head versus ultimate fracture load (r = 0.70; p < 0.001). Conclusion. Simple-to-measure radiographic parameters of the proximal humerus reported previously are more useful in predicting ultimate fracture load than are areal cortical index, canal-to-calcar ratio, and medial cortical ratio. Cite this article: J. G. Skedros, C. S. Mears, W. Z. Burkhead. Ultimate fracture load of cadaver proximal humeri correlates more strongly with mean combined cortical thickness than with areal cortical index, DEXA density, or canal-to-calcar ratio. Bone Joint Res 2017;6:1–7. DOI: 10.1302/2046-3758.61.BJR-2016-0145.R1


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 513 - 518
1 Apr 2014
Terrier A Ston J Larrea X Farron A

The three-dimensional (3D) correction of glenoid erosion is critical to the long-term success of total shoulder replacement (TSR). In order to characterise the 3D morphology of eroded glenoid surfaces, we looked for a set of morphological parameters useful for TSR planning. We defined a scapular coordinates system based on non-eroded bony landmarks. The maximum glenoid version was measured and specified in 3D by its orientation angle. Medialisation was considered relative to the spino-glenoid notch. We analysed regular CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When the maximum version of OA shoulders was higher than 10°, the orientation was not only posterior, but extended in postero-superior (35%), postero-inferior (6%) and anterior sectors (4%). The medialisation of the glenoid was higher in OA than normal shoulders. The orientation angle of maximum version appeared as a critical parameter to specify the glenoid shape in 3D. It will be very useful in planning the best position for the glenoid in TSR. Cite this article: Bone Joint J 2014;96-B:513–18


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims

Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method.

Methods

This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims

Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning.

Methods

A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1600 - 1608
1 Dec 2018
Bouaicha S Ernstbrunner L Jud L Meyer DC Snedeker JG Bachmann E

Aims

In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis.

Materials and Methods

Biomechanical and clinical analyses of the pseudoparalytic shoulder were conducted based on the ratio of the RC/deltoid MAs, which were used to define a novel anatomical descriptor called the Shoulder Abduction Moment (SAM) index. The SAM index is the ratio of the radii of two concentric spheres based on the centre of rotation of the joint. One sphere captures the humeral head (numerator) and the other the deltoid origin of the acromion (denominator). A computational rigid body simulation was used to establish the functional link between the SAM index and a potential predisposition for pseudoparalysis. A retrospective radiological validation study based on these measures was also undertaken using two cohorts with and without pseudoparalysis and massive RC tears.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1074 - 1079
1 Aug 2018
Paul R Knowles N Chaoui J Gauci M Ferreira L Walch G Athwal GS

Aims

The Walch Type C dysplastic glenoid is characterized by excessive retroversion. This anatomical study describes its morphology.

Patients and Methods

A total of 29 shoulders with a dysplastic glenoid were analyzed. CT was used to measure retroversion, inclination, height, width, radius-of-curvature, surface area, depth, subluxation of the humeral head and the Goutallier classification of fatty infiltration. The severity of dysplasia and deficiency of the posterior rim of the glenoid were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1060 - 1065
1 Aug 2018
Hwang J Shields MN Berglund LJ Hooke AW Fitzsimmons JS O’Driscoll SW

Aims

The aim of this study was to evaluate two hypotheses. First, that disruption of posterior bundle of the medial collateral ligament (PMCL) has to occur for the elbow to subluxate in cases of posteromedial rotatory instability (PMRI) and second, that ulnohumeral contact pressures increase after disruption of the PMCL.

Materials and Methods

Six human cadaveric elbows were prepared on a custom-designed apparatus which allowed muscle loading and passive elbow motion under gravitational varus. Joint contact pressures were measured sequentially in the intact elbow (INTACT), followed by an anteromedial subtype two coronoid fracture (COR), a lateral collateral ligament (LCL) tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 68 - 74
1 Jan 2019
Klemt C Toderita D Nolte D Di Federico E Reilly P Bull AMJ

Aims

Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair.

Patients and Methods

Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate in vivo forces during these ADLs. The critical size of a defect was defined as the smallest osseous defect that leads to dislocation.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 331 - 337
1 Mar 2018
Inui H Nobuhara K

Aims

We report the clinical results of glenoid osteotomy in patients with atraumatic posteroinferior instability associated with glenoid dysplasia.

Patients and Methods

The study reports results in 211 patients (249 shoulders) with atraumatic posteroinferior instability. The patients comprised 63 men and 148 women with a mean age of 20 years. The posteroinferior glenoid surface was elevated by osteotomy at the scapular neck. A body spica was applied to maintain the arm perpendicular to the glenoid for two weeks postoperatively. Clinical results were evaluated using the Rowe score and Japan Shoulder Society Shoulder Instability Score (JSS-SIS); bone union, osteoarthrosis, and articular congruity were examined on plain radiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 953 - 956
1 Jul 2018
Erşen A Atalar AC Bayram S Demirel M Tunalı O Demirhan M

Aims

The present study aimed to investigate the long-term functional results of scapulothoracic fusion using multifilament cables in patients with facioscapulohumeral dystrophy (FSHD) to identify if the early improvement from this intervention is maintained.

Patients and Methods

We retrospectively investigated the long-term outcomes of 13 patients with FSHD (18 shoulders) in whom scapulothoracic fusion using multifilament cables was performed between 2004 and 2007. These patients have previously been reported at a mean of 35.5 months (24 to 87). There were eight men and five women with a mean age of 26 years. Their mean length of follow-up of our current study was 128 months (94 to 185). To evaluate long-term functional results, the range of shoulder flexion and abduction, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores were analyzed with a comparison of preoperatively, interim and at the final outcomes. The fusion was examined radiographically in all.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 485 - 492
1 Apr 2018
Gauci MO Bonnevialle N Moineau G Baba M Walch G Boileau P

Aims

Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components.

Materials and Methods

A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, sd 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 927 - 933
1 Jul 2017
Poltaretskyi S Chaoui J Mayya M Hamitouche C Bercik MJ Boileau P Walch G

Aims

Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus.

Materials and Methods

From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 346 - 351
1 Mar 2018
Goodall R Claireaux H Hill J Wilson E Monsell F BOAST 11 Collaborative Tarassoli P

Aims

Supracondylar fractures are the most frequently occurring paediatric fractures about the elbow and may be associated with a neurovascular injury. The British Orthopaedic Association Standards for Trauma 11 (BOAST 11) guidelines describe best practice for supracondylar fracture management. This study aimed to assess whether emergency departments in the United Kingdom adhere to BOAST 11 standard 1: a documented assessment, performed on presentation, must include the status of the radial pulse, digital capillary refill time, and the individual function of the radial, median (including the anterior interosseous), and ulnar nerves.

Materials and Methods

Stage 1: We conducted a multicentre, retrospective audit of adherence to BOAST 11 standard 1. Data were collected from eight hospitals in the United Kingdom. A total of 433 children with Gartland type 2 or 3 supracondylar fractures were eligible for inclusion. A centrally created data collection sheet was used to guide objective analysis of whether BOAST 11 standard 1 was adhered to. Stage 2: We created a quality improvement proforma for use in emergency departments. This was piloted in one of the hospitals used in the primary audit and was re-audited using equivalent methodology. In all, 102 patients presenting between January 2016 and July 2017 were eligible for inclusion in the re-audit.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 218 - 223
1 Feb 2016
Scalise J Jaczynski A Jacofsky M

Aims

The eccentric glenosphere was principally introduced into reverse shoulder arthroplasty to reduce the incidence of scapular notching. There is only limited information about the influence of its design on deltoid power and joint reaction forces.

The aim of our study was to investigate how the diameter and eccentricity of the glenosphere affect the biomechanics of the deltoid and the resultant joint reaction forces.

Methods

Different sizes of glenosphere and eccentricity were serially tested in ten cadaveric shoulders using a custom shoulder movement simulator.


Bone & Joint Research
Vol. 5, Issue 6 | Pages 269 - 275
1 Jun 2016
Ono Y Woodmass JM Nelson AA Boorman RS Thornton GM Lo IKY

Objectives

This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P).

Methods

Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims

Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component.

Patients and Methods

A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°).


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1539 - 1545
1 Nov 2015
Lenoir H Chammas M Micallef JP Lazerges C Waitzenegger T Coulet B

Determining and accurately restoring the flexion-extension axis of the elbow is essential for functional recovery after total elbow arthroplasty (TEA). We evaluated the effect of morphological features of the elbow on variations of alignment of the components at TEA. Morphological and positioning variables were compared by systematic CT scans of 22 elbows in 21 patients after TEA.

There were five men and 16 women, and the mean age was 63 years (38 to 80). The mean follow-up was 22 months (11 to 44).

The anterior offset and version of the humeral components were significantly affected by the anterior angulation of the humerus (p = 0.052 and p = 0.004, respectively). The anterior offset and version of the ulnar components were strongly significantly affected by the anterior angulation of the ulna (p < 0.001 and p < 0.001).

The closer the anterior angulation of the ulna was to the joint, the lower the ulnar anterior offset (p = 0.030) and version of the ulnar component (p = 0.010). The distance from the joint to the varus angulation also affected the lateral offset of the ulnar component (p = 0.046).

Anatomical variations at the distal humerus and proximal ulna affect the alignment of the components at TEA. This is explained by abutment of the stems of the components and is particularly severe when there are substantial deformities or the deformities are close to the joint.

Cite this article: Bone Joint J 2015;97-B:1539–45.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer.

Cite this article: Bone Joint J 2015;97-B:1657–61.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1074 - 1079
1 Aug 2016
Königshausen M Coulibaly MO Nicolas V Schildhauer TA Seybold D

Aims

Our aim was to investigate the outcomes of patients with a displaced fracture of the glenoid fossa who are treated conservatively. There is little information in the literature about the treatment of these rare injuries non-operatively.

Patients and Methods

We reviewed 24 patients with a mean age of 52 years (19 to 81) at a mean of 5.6 years (11 months to 18 years) after the injury.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor.

Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid.

All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001).

Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery.

A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy.

Cite this article: 2015;97-B:1090–5.