We investigated the incidence of and risk factors
for venous thromboembolism (VTE) following surgery of the shoulder
and elbow and assessed the role of thromboprophylaxis in upper limb
surgery. All papers describing VTE after shoulder and elbow surgery
published in the English language literature before 31 March 2012
were reviewed. A total of 14 papers were available for analysis,
most of which were retrospective studies and case series. The incidence
of VTE was 0.038% from 92 440 shoulder arthroscopic procedures,
0.52% from 42 261 shoulder replacements, and 0.64% from 4833 procedures
for fractures of the proximal humerus (open reduction and internal fixation
or hemiarthroplasty). The incidence following replacement of the
elbow was 0.26% from 2701 procedures. Diabetes mellitus, rheumatoid
arthritis and ischaemic heart disease were identified as the major
risk factors. The evidence that exists on thromboprophylaxis is based on level
III and IV studies, and we therefore cannot make any recommendations
on prophylaxis based on the current evidence. It seems reasonable
to adopt a multimodal approach that involves all patients receiving
mechanical prophylaxis, with chemical prophylaxis reserved for those
who are at high risk for VTE. Cite this article:
The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate? PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments.Aims
Methods
This study aimed to define the histopathology of degenerated humeral head cartilage and synovial inflammation of the glenohumeral joint in patients with omarthrosis (OmA) and cuff tear arthropathy (CTA). Additionally, the potential of immunohistochemical tissue biomarkers in reflecting the degeneration status of humeral head cartilage was evaluated. Specimens of the humeral head and synovial tissue from 12 patients with OmA, seven patients with CTA, and four body donors were processed histologically for examination using different histopathological scores. Osteochondral sections were immunohistochemically stained for collagen type I, collagen type II, collagen neoepitope C1,2C, collagen type X, and osteocalcin, prior to semiquantitative analysis. Matrix metalloproteinase (MMP)-1, MMP-3, and MMP-13 levels were analyzed in synovial fluid using enzyme-linked immunosorbent assay (ELISA).Aims
Methods
Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative
The purpose of this study was to compare the
outcome and
This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical
We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency. Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related
We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early
We analysed the long-term results of arthrodesis of the shoulder after infection in 15 patients. At the time of operation, 14 cultures were positive for Staphylococcus aureus. The mean follow-up was 8.3 years (3 to 14) and 90% of the patients were satisfied with the outcome. There were
Displaced fractures of the lateral end of the clavicle in young patients have a high incidence of nonunion and a poor functional outcome after conservative management. Operative treatment is therefore usually recommended. However, current techniques may be associated with
This study reports our experience with total elbow replacement for fused elbows. Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically. A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high
While frequently discussed as a standard treatment for the management of an infected shoulder replacement, there is little information on the outcome of two-stage re-implantation. We examined the outcome of 17 consecutive patients (19 shoulders) who were treated between 1995 and 2004 with a two-stage re-implantation for the treatment of a deep-infection after shoulder replacement. All 19 shoulders were followed for a minimum of two years or until the time of further revision surgery. The mean clinical follow-up was for 35 months (24 to 80). The mean radiological follow-up was 27 months (7 to 80). There were two excellent results, four satisfactory and 13 unsatisfactory. In 12 of the 19 shoulders (63%) infection was considered to be eradicated. The mean pain score improved from 4.2 (3 to 5 (out of 5)) to 1.8 (1 to 4). The mean elevation improved from 42° (0° to 140°) to 89° (0° to 165°), mean external rotation from 30° (0° to 90°) to 43° (0° to 90°), and mean internal rotation from the sacrum to L5. There were 14
Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3). Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p <
0.0001). The mean active abduction improved from 88° to 107° (p <
0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative
We compared six patients with a mean age of 70 years (49 to 80) with severe bilateral, painful glenohumeral joint destruction who underwent a single-stage bilateral total shoulder replacement, with eight patients of mean age 61 years (22 to 89) who underwent bilateral total shoulder replacement in two stages, at a mean interval of 18 months (6 to 43). The overall function, pain and strength improved significantly in both groups. The subjective shoulder value, relative Constant score, active external rotation and the strength were improved significantly more in the single-stage group. Active elevation, abduction and overall function improved, significantly more in the single-stage group. Both the total duration of hospitalisation and the time off work per shoulder were substantially shorter in the single-stage group. The overall rate of
Cubitus varus and valgus are the most common
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and
We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty. Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant
Malunion is the most common
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for dislocation of the humeral head,
one open reduction for modular humeral component dissociation, one
internal fixation for nonunion, one trimming of a prominent screw
and one re-cementation for aseptic loosening complicated by infection,
ultimately requiring excision arthroplasty. Two patients sustained
nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated
with bone loss and/or loose components is a salvage procedure that
can provide a stable platform for elbow and hand function. Good
rates of union can be achieved using a stem that bypasses the fracture.
There is a high rate of
Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related
This is a retrospective review of the results of the Acclaim total elbow replacement in 11 older patients aged ≥ 65 years with primary osteoarthritis of the elbow, with a mean follow-up of 57.6 months (30 to 86.4). Significant reductions in pain and improvement in range of movement and function were recorded. Radiological review revealed two patients with 1 mm lucencies in a single zone, and one patient with 1 mm lucencies in two zones. No components required revision. There were no deep infections, dislocations or mechanical failures. Complications included one intra-operative medial condylar fracture and one post-operative transient ulnar neuropathy, which resolved. This study demonstrates that the Acclaim prosthesis provides good symptomatic relief and improvement of function in patients with primary osteoarthritis, with low rates of loosening or other
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related
We present the results of a retrospective series of 41 Sauve-Kapandji procedures carried out for
The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching. The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired t-test, p <
0.001) at final follow-up. The mean Oxford score was 44 (95% CI 40 to 51) pre-operatively and 23 (95% CI 18 to 28) (paired t-test, p <
0.001) at final follow-up. The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven
Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p <
0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative
We present the results of 525 primary Souter elbow arthroplasties undertaken in 406 patients between 1982 and 1997. There were 372 women and 34 men with a mean age of 57 years; 119 patients had a bilateral procedure. The elbows were affected by chronic inflammatory disease, usually rheumatoid arthritis, which had been present for a mean of 24.7 years (2 to 70). In about 30% the joints were grossly destroyed with significant loss of bone. In 179 elbows the ulnar components were metal-backed and retentive; in the remaining 346, with better bone stock, non-retentive, all-polyethylene prostheses were used. Because of
Ulnar neuropathy presents as a
We report the results of a series of 59 unconstrained total arthroplasties of the elbow after a mean follow-up of 6.5 years (4 to 10). All the patients had rheumatoid arthritis. The indication for surgery was pain in all but one. Outcome was assessed by the Mayo Elbow Performance Index (MEPI). Of the 59 arthroplasties, two were lost to follow-up. Ten patients died, but as two of their arthroplasties were failures we included them in the results. The outcome in the remaining 49 was excellent in 26 (53%), good in 15 (31%), fair in one (2%) and poor or a failure in seven (14%). There was an improvement in the pain score (p <
0.001), movement (p <
0.001) and function (p <
0.001). Two patients developed instability, but neither required further surgery. There was a mean increase of 21° in flexion and of 7° in extension. The overall rate of
Between 1995 and 2006, five intra-articular osteotomies of the head of the radius were performed in patients with symptomatic healed displaced articular fractures. Pre-operatively, all patients complained of persistent painful clicking on movement. Only patients with mild or no degenerative changes of the radial head and capitellum were considered for osteotomy. The operations were performed at a mean of 8.2 months (4 to 13) after injury and the patients were reviewed at a mean of 5.5 years (15 months to 12 years) after the osteotomy. The average Mayo Elbow Performance Index Score improved significantly from 74 before to 88 after operation, with four patients rated as good or excellent (p <
0.05). The subjective patient satisfaction score was 8.4 on a ten-point scale. All osteotomies healed and there were no
The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported
We describe a new method of stabilising a painful unstable sternoclavicular joint using the sternocleidomastoid tendon and passing it through the medial clavicle and onto the manubrium sternum. This method is simple, reproducible and avoids the potential risks of reefing the joint to the first rib. The technique was used in seven cases of sternoclavicular joint instability in six patients who were reviewed at a mean of 39.7 months (15 to 63). Instability was markedly reduced or eliminated in all cases, but in one there was occasional persistant subluxation. There were minor scar
We randomised 79 patients (84 hands, 90 fingers) with Dupuytren’s contracture of the proximal interphalangeal joint to have either a ‘firebreak’ skin graft (39 patients, 41 hands, 44 fingers) or a fasciectomy (40 patients, 43 hands, 46 fingers) if, after full correction, the skin over the proximal phalanx could be easily closed by a Z-plasty. Patients were reviewed after three, six, 12, 24 and 36 months to note any
Our aim in this prospective study was to evaluate the outcome of total shoulder replacement in the treatment of young and middle-aged active patients with primary glenohumeral osteoarthritis. We reviewed 21 patients (21 shoulders) with a mean age of 55 years (37 to 60). The mean follow-up was seven years (5 to 9). The same anatomical, third-generation, cemented implant had been used in all patients. All the patients were evaluated radiologically and clinically using the Constant and Murley score. No patients required revision. In one a tear of the supraspinatus tendon occurred. Overall, 20 patients (95%) were either very satisfied (n = 18) or satisfied (n = 2) with the outcome. Significant differences (p <
0.0001) were found for all categories of the Constant and Murley score pre- and post-operatively. The mean Constant and Murley score increased from 24.1 points (10 to 45) to 64.5 points (39 to 93), and the relative score from 30.4% (11% to 50%) to 83% (54% to 116%). No clinical or radiological signs of loosening of the implant were seen. For young and middle-aged patients with osteoarthritis, third-generation total shoulder replacement is a viable method of treatment with a low rate of
We describe the results of Copeland surface replacement shoulder arthroplasty using the mark III prosthesis in patients over 80 years of age. End-stage arthritis of the shoulder is a source of significant pain and debilitating functional loss in the elderly. An arthroplasty offers good relief of pain and may allow the patient to maintain independence. The risk-benefit ratio of shoulder replacement may be felt to be too high in an elderly age group, but there is no published evidence to support this theory. We have assessed whether the procedure was as reliable and safe as previously seen in a younger cohort of patients. Between 1993 and 2003, 213 Copeland surface replacement arthroplasty procedures were performed in our unit, of which 29 (13.6%) were undertaken in patients over the age of 80. This group of patients was followed up for a mean of 4.5 years (2.1 to 9.3). Their mean age was 84.3 years (81 to 93), the mean operating time was 40 minutes (30 to 45) and the mean in-patient stay was five days (2 to 21). There were no peri-operative deaths or significant
Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex. Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound
We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months. Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group. Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative
We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with
We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major
We examined the effects of previous resection of the radial head and synovectomy on the outcome of subsequent total elbow arthroplasty in patients with rheumatoid arthritis. Fifteen elbows with a history of resection and synovectomy were compared with a control group of patients who had elbow arthroplasty with an implant of the same design. The mean age in both groups was 63 years. In the study group, resection of the radial head and synovectomy had been undertaken at a mean of 8.9 years before arthroplasty. The mean radiological follow-up for the 13 available patients in the study group was 5.89 years (0.3 to 11.0) and in the control group was 6.6 years (2.2 to 12.6). There were no revisions in either group. The mean Mayo elbow performance score improved from 29 to 96 in the study group, with similar improvement in the control group (28 to 87). The study group had excellent results in 13 elbows and good results in two. The control group had excellent results in seven and good results in six. Our experience indicates that previous resection of the radial head and synovectomy are not associated with an increased rate of revision following subsequent arthroplasty of the elbow. However, there was a higher rate of
Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis. This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant
We report the results of performing a pronating osteotomy of the radius, coupled with other soft-tissue procedures, as part of an upper limb functional surgery programme in tetraplegic patients with supination contractures. In total 12 patients were reviewed with a mean follow-up period of 60 months (12 to 109). Pre-operatively, passive movement ranged from a mean of 19.2° pronation (−70° to 80°) to 95.8° supination (80° to 140°). A pronating osteotomy of the radius was then performed with release of the interosseous membrane. Extension of the elbow was restored postoperatively in 11 patients, with key-pinch reconstruction in nine. At the final follow-up every patient could stabilise their hand in pronation, with a mean active range of movement of 79.6° (60° to 90°) in pronation and 50.4° (0° to 90°) in supination. No
There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction. Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14
We describe a technique of soft-tissue reconstruction which is effective for the treatment of chronic lunotriquetral instability. Part of extensor carpi ulnaris is harvested with its distal attachment preserved. It is passed through two drill holes in the triquetrum and sutured to itself. This stabilises the ulnar side of the wrist. We have reviewed 46 patients who underwent this procedure for post-traumatic lunotriquetral instability with clinical signs suggestive of ulnar-sided carpal instability. Standard radiographs were normal. All patients had pre-operative arthroscopy of the wrist at which dynamic lunotriquetral instability was demonstrated. A clinical rating system for the wrist by the Mayo clinic was used to measure the outcome. In 19 patients the result was excellent, in ten good, in 11 satisfactory and in six poor. On questioning, 40 (87%) patients said that surgery had substantially improved the condition and that they would recommend the operation. However, six (13%) were unhappy with the outcome and would not undergo the procedure again for a similar problem. There were six
In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used. We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography. Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% vs 92%; rate of further tear, 18% vs 22%; and revision, 4% vs 4%. In cases of further tear the outcome in group 2 did not differ from that for the intact repairs (91% vs 91%), but in group 1 it was significantly worse (94% vs 77%, p = 0.005). Overall, seven patients had
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function. No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other
Patients with short congenital amputations below the elbow often function as if they have had a disarticulation of the elbow. We have reviewed the results in six patients who had lengthening of such stumps by the Ilizarov technique to improve the fitting of prostheses. The mean lengthening was 5.6 cm (3.4 to 8.4), and in two patients flexion contractures of the elbows were corrected simultaneously. Additional lateral distraction was used in one patient to provide a better surface on the stump. There were no major
We have used a modified technique in five patients to correct winging of the scapula caused by injury to the brachial plexus or the long thoracic nerve during transaxillary resection of the first rib. The procedure stabilises the scapulothoracic articulation by using strips of autogenous fascia lata wrapped around the 4th, 6th and 7th ribs at least two, and preferably three, times. The mean age of the patients at the time of operation was 38 years (26 to 47) and the mean follow-up six years and four months (three years and three months to 11 years). Satisfactory stability was achieved in all patients with considerable improvement in shoulder function. There were no
Between June 1991 and May 1996 we carried out arthrodesis on 15 patients with flail or partially flail wrists using an AO/ASIF dynamic compression plate (DCP) without a bone graft. The wrist was approached through the second extensor compartment. The minimum follow-up was for 24 months with a mean of 34.2 months. All 15 wrists fused without major
We describe four women and two men who had persistent wrist pain and reduced function after minor operations on the dorsum, usually for ganglia. They had diffuse pain and paraesthesia over the dorsum of the wrist, thumb, index and middle fingers, which was worse and different from that before operation. They all had temporary relief of symptoms after block of the posterior interosseous nerve with bupivacaine. Later, excision of the terminal branches of the nerve at the wrist cured three patients completely and gave marked improvement in the other three, with no
Osteoarthritis of the wrist is a
We studied 57 patients with isolated lunotriquetral injuries treated by arthrodesis, direct ligament repair, or ligament reconstruction. The outcomes were compared by using written questionnaires, the Disabilities of the Arm, Shoulder and Hand (DASH) score, range of movement, strength, morbidity and rates of reoperation. Isolated lunotriquetral injury was confirmed by arthroscopy or arthrotomy. The mean age of the patients was 30.7 years (15.4 to 53.7) and the injuries were subacute or chronic in 98.2%. Eight patients underwent lunotriquetral reconstruction using a distally-based strip of the tendon of extensor carpi ulnaris, 27 had lunotriquetral repair and 22 had lunotriquetral arthrodesis. The mean follow-up was 9.5 years (2 to 22). The probability of remaining free from
Between 1986 and 1994, 13 patients with mobile painful arthritic elbows were treated by distraction interposition arthroplasty using fascia lata. The mean period of follow-up was 63 months. An elbow distractor/fixator was applied for three to four weeks to separate the articular surfaces and to protect the fascial graft. Nine of the 13 patients (69%) had satisfactory relief from pain; eight (62%) had an excellent or good result by the objective criteria of the Mayo Elbow Performance score. Four have required revision to total elbow arthroplasty at a mean of 30 months with good results to date. Instability of the elbow, both before and after surgery, was found to be associated with unsatisfactory results. The rate of success when the procedure was performed for inflammatory arthritis was similar to that for post-traumatic arthritis, about 67%. Eight
We have reviewed 66 consecutive Souter-Strathclyde arthroplasties of the elbow implanted in 59 patients between 1982 and 1993. Thirteen patients (15 elbows) (19.6%) died. Sixteen elbows (24.2%) were revised, six for aseptic loosening (9%), four (6%) because of fracture or loosening after a fracture, three (4.5%) for infection and three (4.5%) for dislocation. Four patients refused to attend for review. In 33 elbows with a follow-up of 93 months (60 to 167) complete relief of pain was achieved in 22 (67%) when seen at one year. After ten years or more 36% of the elbows were painfree and 64% had occasional slight pain especially under loading or stress. The mean gain in the arc of movement was 16°, but a mean flexion contracture of 33° remained. The main early
From 1984 to 1995, 68 ankylosed elbows and 11 which were unstable after trauma were replaced in India by Baksi sloppy hinge prostheses. The mean age of the patients was 28.6 years (17 to 70) and the mean follow-up 9.6 years (2 to 13.5). Of the 68 ankylosed elbows, 59 (87%) regained a mean arc of painless movement of 88.5° (27 to 115). The mean improvement of supination was 24° and of pronation 16.5°. There were 54 good results (80%), eight fair and three poor. There were two complete failures due to infection, and one due to a broken humeral stem. Of the 11 unstable elbows, the nine with good results had a mean arc of 125° (15 to 140) of painless stable movement, with a mean improvement in supination of 26° and of pronation of 19.5°. There was one fair result and one failure due to loosening with subsequent late infection. There were significant
Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed. The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA. There were three cases of aseptic loosening and three of deep infection. The main
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results
Necrotising soft-tissue infections (NSTIs) of
the upper limb are uncommon, but potentially life-threatening. We
used a national database to investigate the risk factors for amputation
of the limb and death. We extracted data from the Japanese Diagnosis Procedure Combination
database on 116 patients (79 men and 37 women) who had a NSTI of
the upper extremity between 2007 and 2010. The overall in-hospital mortality was 15.5%. Univariate analysis
of in-hospital mortality showed that the significant variables were
age (p = 0.015), liver dysfunction (p = 0.005), renal dysfunction
(P <
0.001), altered consciousness (p = 0.049), and sepsis (p
= 0.021). Logistic regression analysis showed that the factors associated with
death in hospital were age over 70 years (Odds Ratio (OR) 6.6; 95%
confidence interval (CI) 1.5 to 28.2; p = 0.011) and renal dysfunction
(OR 15.4; 95% CI 3.8 to 62.8; p <
0.001). Univariate analysis of limb amputation showed that the significant
variables were diabetes (p = 0.017) mellitus and sepsis (p = 0.001).
Multivariable logistic regression analysis showed that the factors
related to limb amputation were sepsis (OR 1.8; 95% CI 1.5 to 24.0;
p = 0.013) and diabetes mellitus (OR 1.6; 95% CI 1.1 to 21.1; p
= 0.038). For NSTIs of the upper extremity, advanced age and renal dysfunction
are both associated with a higher rate of in-hospital mortality.
Sepsis and diabetes mellitus are both associated with a higher rate
of amputation. Cite this article:
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. Cite this article:
Most patients with a nightstick fracture of the
ulna are treated conservatively. Various techniques of immobilisation or
early mobilisation have been studied. We performed a systematic
review of all published randomised controlled trials and observational
studies that have assessed the outcome of these fractures following
above- or below-elbow immobilisation, bracing and early mobilisation.
We searched multiple electronic databases, related bibliographies and
other studies. We included 27 studies comprising 1629 fractures
in the final analysis. The data relating to the time to radiological
union and the rates of delayed union and nonunion could be pooled
and analysed statistically. We found that early mobilisation produced the shortest radiological
time to union (mean 8.0 weeks) and the lowest mean rate of nonunion
(0.6%). Fractures treated with above- or below-elbow immobilisation
and braces had longer mean radiological times to union (9.2 weeks,
9.2 weeks and 8.7 weeks, respectively) and higher mean rates of
nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically
significant difference in the rate of non- or delayed union between
those treated by early mobilisation and the three forms of immobilisation
(p = 0.142 to p = 1.000, respectively). All the studies had significant
biases, but until a robust randomised controlled trial is undertaken
the best advice for the treatment of undisplaced or partially displaced
nightstick fractures appears to be early mobilisation, with a removable
forearm support for comfort as required. Cite this article:
Instability after arthroplasty of the shoulder
is difficult to correct surgically. Soft-tissue procedures and revision surgery
using unconstrained anatomical components are associated with a
high rate of failure. The purpose of this study was to determine
the results of revision of an unstable anatomical shoulder arthroplasty
to a reverse design prosthesis. Between 2004 and 2007, 33 unstable
anatomical shoulder arthroplasties were revised to a reverse design.
The mean age of the patients was 71 years (53 to 86) and their mean
follow-up was 42 months (25 to 71). The mean time to revision was
26 months (4 to 164). Pain scores improved significantly (pre-operative
visual analogue scale (VAS) of 7.2 ( Cite this article:
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
This study provides recommendations on the position
of the implant in reverse shoulder replacement in order to minimise
scapular notching and osteophyte formation. Radiographs from 151
patients who underwent primary reverse shoulder replacement with
a single prosthesis were analysed at a mean follow-up of 28.3 months
(24 to 44) for notching, osteophytes, the position of the glenoid
baseplate, the overhang of the glenosphere, and the prosthesis scapular
neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four
Grade 2) and 47 (31.1%) had an osteophyte. In patients without either
notching or an osteophyte the baseplate was found to be positioned
lower on the glenoid, with greater overhang of the glenosphere and
a lower PSNA than those with notching and an osteophyte. Female patients
had a higher rate of notching than males (13.3% Based on these findings we make recommendations on the placement
of the implant in both male and female patients to avoid notching
and osteophyte formation. Cite this article:
Lateral clavicular physeal injuries in adolescents
are frequently misinterpreted as acromioclavicular dislocations. There
are currently no clear guidelines for the management of these relatively
rare injuries. Non-operative treatment can result in a cosmetic
deformity, warranting resection of the non-remodelled original lateral
clavicle. However, fixation with Kirschner (K)-wires may be associated
with infection and/or prominent metalwork. We report our experience
with a small series of such cases. Between October 2008 and October 2011 five patients with lateral
clavicular physeal fractures (types III, IV and V) presented to
our unit. There were four boys and one girl with a mean age of 12.8
years (9 to 14). Four fractures were significantly displaced and
treated operatively using a tension band suture technique. One grade
III fracture was treated conservatively. The mean follow-up was
26 months (6 to 42). All patients made an uncomplicated recovery. The mean time to
discharge was three months. The QuickDASH score at follow-up was
0 for each patient. No patient developed subsequent growth disturbances. We advocate the surgical treatment of significantly displaced
Grade IV and V fractures to avoid cosmetic deformity. A tension
band suture technique avoids the problems of retained metalwork
and the need for a secondary procedure. Excellent clinical and radiological
results were seen in all our patients. Cite this article:
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
There is little published information on the
health impact of frozen shoulder. The purpose of this study was
to assess the functional and health-related quality of life outcomes
following arthroscopic capsular release (ACR) for contracture of
the shoulder. Between January 2010 and January 2012 all patients
who had failed non-operative treatment including anti-inflammatory
medication, physiotherapy and glenohumeral joint injections for
contracture of the shoulder and who subsequently underwent an ACR
were enrolled in the study. A total of 100 patients were eligible;
68 underwent ACR alone and 32 had ACR with a subacromial decompression
(ASD). ACR resulted in a highly significant improvement in the range
of movement and functional outcome, as measured by the Oxford shoulder
score and EuroQol EQ-5D index. The mean cost of a quality-adjusted
life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189,
respectively. ACR is thus a cost-effective procedure that can restore relatively
normal function and health-related quality of life in most patients
with a contracture of the shoulder within six months after surgery;
and the beneficial effects are not related to the duration of the
presenting symptoms. Cite this article:
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean Oxford shoulder score improved from
20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions
had lower overall functional scores but achieved greater improvements
following STF. The mean active forward elevation increased from
59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10°
to 90°) to 83° (30° to 130°) with a greater range of movement achieved
in the dystrophic group. Revision fusion for nonunion was undertaken
in five patients at a mean time of 17 months (7 to 31) and two required
revision for fracture. There were three pneumothoraces, two rib
fractures, three pleural effusions and six nonunions. The main risk
factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction
in 82% of patients with both dystrophic and non-dystrophic pathologies,
but there was a relatively high failure rate (26%) when poor outcomes
were analysed. Overall function was better in patients with dystrophic
conditions which correlated with better range of movement; however,
patients with non-dystrophic conditions achieved greater functional
improvement.
In adults with brachial plexus injuries, lack
of active external rotation at the shoulder is one of the most common residual
deficits, significantly compromising upper limb function. There
is a paucity of evidence to address this complex issue. We present
our experience of isolated latissimus dorsi (LD) muscle transfer
to achieve active external rotation. This is a retrospective review
of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus
dorsi muscle transfer to restore external rotation of the shoulder
between 1997 and 2010. All patients were male with a mean age of
34 years (21 to 57). All the patients underwent isolated LD muscle
transfer using a standard technique to correct external rotational
deficit. Outcome was assessed for improvement in active external rotation,
arc of movement, muscle strength and return to work. The mean improvement
in active external rotation from neutral was 24° (10° to 50°). The
mean increase in arc of rotation was 52° (38° to 55°). Mean power
of the external rotators was 3.5 Medical Research Council (MRC)
grades (2 to 5). A total of 21 patients (88%) were back in work by the time of
last follow up. Of these,
13 had returned to their pre-injury occupation. Isolated latissimus
dorsi muscle transfer provides a simple and reliable method of restoring
useful active external rotation in adults with brachial plexus injuries
with internal rotational deformity. Cite this article:
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
The Motec cementless modular metal-on-metal ball-and-socket
wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion
advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate
advanced collapse (SLAC) in 30 patients (20 men) with severe (grades
3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of
the patients was 52 years (31 to 71). All prostheses integrated
well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1)
no luxation or implant breakage occurred. Two wrists were converted
to an arthrodesis for persistent pain. Loosening occurred in one
further wrist at five years post-operatively. The remainder demonstrated close
bone–implant contact. The clinical results were good, with markedly
decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain
scores, and increased movement and grip strength. No patient used
analgesics and most had returned to work. Good short-term function was achieved using this wrist arthroplasty
in a high-demand group of patients with post-traumatic osteoarthritis.
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior dislocations of the shoulder underwent
a Latarjet procedure and were reviewed at a mean of 8.3 years (1
to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°)
to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°)
to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to
100) at the final follow-up. Radiologically, all shoulders showed
a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes
of the glenohumeral joint were observed in five shoulders (36%)
pre-operatively and in eight shoulders (57%) post-operatively.
Re-dislocation during a seizure occurred in six shoulders (43%).
Five of these patients underwent revision surgery using a bone buttress
from the iliac crest and two of these patients re-dislocated due
to a new seizure. Due to the unacceptably high rate of re-dislocation after surgery
in these patients, the most important means of reducing the incidence
of further dislocation is the medical management of the seizures.
The Latarjet procedure should be reserved for the well-controlled
patient with epilepsy who has recurrent anterior dislocation of
the shoulder during activities of daily living.
The aim of this study was to determine whether there is any significant
difference in temporal measurements of pain, function and rates
of re-tear for arthroscopic rotator cuff repair (RCR) patients compared
with those patients undergoing open RCR. This study compared questionnaire- and clinical examination-based
outcomes over two years or longer for two series of patients who
met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR
patients. All surgery was performed by a single surgeon. Objectives
Methods
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement
Radial osteotomy is currently advocated for patients
with Lichtman’s stages II and IIIA of Kienböck’s disease; its place
in the treatment of patients with stage IIIB disease remains controversial.
The purpose of this study was to evaluate the medium-term results
of this procedure and to compare the outcome in patients with stage
IIIB disease and those with earlier stages (II and IIIA). A total
of 18 patients (18 osteotomies) were evaluated both clinically and radiologically
at a mean follow-up of 10.3 years (4 to 18). Range of movement,
grip strength and pain improved significantly in all patients; the
functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability
(Disabilities of Arm, Shoulder and Hand questionnaire) was low at
the final follow-up in all patients evaluated. Patients with stage
IIIB disease, however, had a significantly lower grip strength,
lower NSSK scores and higher disability than those in less advanced
stages. Radiological progression of the disease was not noted in
either group, despite the stage. Radial osteotomy seems effective
in halting the progression of disease and improving symptoms in
stages II, IIIA and IIIB. Patients with less advanced disease should
be expected to have better clinical results.
We report the effectiveness of revision of total
elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows
in 52 patients were treated with re-cementing of a total elbow replacement
into part or all of the existing cement mantle or into the debrided
host-bone interface, without the use of structural bone augmentation
or a custom prosthesis. The original implant revision was still
Dislocation of the shoulder may occur during
seizures in epileptics and other patients who have convulsions. Following
the initial injury, recurrent instability is common owing to a tendency
to develop large bony abnormalities of the humeral head and glenoid
and a susceptibility to further seizures. Assessment is difficult
and diagnosis may be missed, resulting in chronic locked dislocations
with protracted morbidity. Many patients have medical comorbidities,
and successful treatment requires a multidisciplinary approach addressing
the underlying seizure disorder in addition to the shoulder pathology.
The use of bony augmentation procedures may have improved the outcomes
after surgical intervention, but currently there is no evidence-based
consensus to guide treatment. This review outlines the epidemiology
and pathoanatomy of seizure-related instability, summarising the
currently-favoured options for treatment, and their results.
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
Injectable collagenase is an alternative to surgical
treatment for Dupuytren’s disease. Previous studies have reported
on the effectiveness of collagenase in finger contractures. This
prospective study reports on the short-term safety and efficacy
of collagenase treatment in five thumb and first web space Dupuytren’s
contractures. The thumb and first web space contractures were treated
with injectable collagenase in four consecutive patients (five hands) with
experience of previous surgical digital fasciectomy. The thumb contracture
was measured by angle and span in two planes of thumb extension
and abduction before injection and after manipulation. Collagenase
treatment resulted in release of the contracture with a mean increase
in thumb to index angle from 23° (10° to 35°) to 56° (45° to 60°)
in extension and from 30° (10° to 50°) to 58° (50° to 65°) in abduction
and a mean increase in span from 1.9 cm (1 to 3.5) to 3.9 cm (3
to 5) in extension and from 2.4 cm (1.5 to 3.5) to 3.9 cm (3 to
4.5) in abduction. All patients reported an increased range of movement
and function and described collagenase therapy as preferable to
surgery. In the short-term collagenase is an effective, well-tolerated
and safe alternative to surgery for Dupuytren’s disease of the thumb.
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist using non-vascularised osteochondral autografts
are reviewed.
A total of 92 patients with symptoms for over
six months due to subacromial impingement of the shoulder, who were
being treated with physiotherapy, were included in this study. While
continuing with physiotherapy they waited a further six months for
surgery. They were divided into three groups based on the following
four clinical and radiological criteria: temporary benefit following
steroid injection, pain in the mid-arc of abduction, a consistently positive
Hawkins test and radiological evidence of impingement. Group A fulfilled
all four criteria, group B three criteria and group C two criteria.
A total of nine patients improved while waiting for surgery and
were excluded, leaving 83 who underwent arthroscopic subacromial
decompression (SAD). The new Oxford shoulder score was recorded
pre-operatively and at three and 12 months post-operatively. A total of 51 patients (group A) had a significant improvement
in the mean shoulder score from 18 (13 to 22) pre-operatively to
38 (35 to 42) at three months (p <
0.001). The mean score in
this group was significantly better than in group B (21 patients)
and C (11 patients) at this time. At one year patients in all groups
showed improvement in scores, but patients in group A had a higher
mean score (p = 0.01). At one year patients in groups A and B did
better than those in group C (p = 0.01). Arthroscopic SAD is a beneficial intervention in selected patients.
The four criteria could help identify patients in whom it is likely
to be most effective.
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p <
0.001), as was resorption of the greater (p <
0.001) and lesser tuberosities (p = 0.009).
Diabetes mellitus is recognised as a risk factor
for carpal tunnel syndrome. The response to treatment is unclear,
and may be poorer than in non-diabetic patients. Previous randomised
studies of interventions for carpal tunnel syndrome have specifically
excluded diabetic patients. The aim of this study was to investigate
the epidemiology of carpal tunnel syndrome in diabetic patients,
and compare the outcome of carpal tunnel decompression with non-diabetic
patients. The primary endpoint was improvement in the QuickDASH
score. The prevalence of diabetes mellitus was 11.3% (176 of 1564).
Diabetic patients were more likely to have severe neurophysiological
findings at presentation. Patients with diabetes had poorer QuickDASH
scores at one year post-operatively (p = 0.028), although the mean
difference was lower than the minimal clinically important difference
for this score. After controlling for underlying differences in
age and gender, there was no difference between groups in the magnitude of
improvement after decompression (p = 0.481). Patients with diabetes
mellitus can therefore be expected to enjoy a similar improvement
in function.
We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening ( Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.
We compared the outcome of arthroscopic repair of the rotator cuff in 32 diabetic patients with the outcome in 32 non-diabetic patients matched for age, gender, size of tear and comorbidities. The Constant-Murley score improved from a mean of 49.2 (24 to 80) pre-operatively to 60.8 (34 to 95) post-operatively (p = 0.0006) in the diabetic patients, and from 46.4 (23 to 90) pre-operatively to 65.2 (25 to 100) post-operatively (p = 0.0003) in the non-diabetic patients at six months. This was significantly greater (p = 0.0002) in non-diabetic patients (18.8) than in diabetics (11.6). There was no significant change in the mean mental component of the Short-Form 12, but the mean physical component increased from 35 to 41 in non-diabetics (p = 0.0001), and from 37 to 39 (p = 0.15) in diabetics. These trends were observed at one year. Patients with diabetes showed improvement of pain and function following arthroscopic rotator cuff repair in the short term, but less than their non-diabetic counterparts.
We retrospectively reviewed 11 consecutive patients with an infected reverse shoulder prosthesis. Patients were assessed clinically and radiologically, and standard laboratory tests were carried out. Peroperative samples showed Propionbacterium acnes in seven, coagulase-negative Staphylococcus in five, methicillin-resistant A one-stage revision arthroplasty reduces the cost and duration of treatment. It is reliable in eradicating infection and good functional outcomes can be achieved.
We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior bone block stabilisation for recurrent posterior instability of the shoulder in a heterogenous group of 11 patients previously reported on in 2001 at a median follow-up of six years. We found that five (45%) would not have chosen the operation again, and that four (36%) had further posterior dislocation. Clinical outcome was significantly worse after 18 years than after six years of follow-up (median Rowe score of 60 versus 90 (p = 0.027)). The median Western Ontario Shoulder Index was 60% (37% to 100%) at 18 years’ follow-up, which is a moderate score. At the time of surgery four (36%) had glenohumeral radiological osteoarthritis, which was present in all after 18 years. This study showed poor long-term results of the posterior bone block procedure for posterior instability and a high rate of glenohumeral osteoarthritis although three patients with post-traumatic instability were pleased with the result of their operations.
This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.
The integrity of the spinal accessory nerve is fundamental to thoracoscapular function and essential for scapulohumeral rhythm. This nerve is vulnerable along its superficial course. This study assessed the delay in diagnosis and referral for management of damage to this nerve, clarified its anatomical course and function, and documented the results of repair. From examination of our records, 111 patients with lesions of the spinal accessory nerve were treated between 1984 and 2007. In 89 patients (80.2%) the damage was iatropathic. Recognition and referral were seldom made by the surgeon responsible for the injury, leading to a marked delay in instituting treatment. Most referrals were made for painful loss of shoulder function. The clinical diagnosis is straightforward. There is a characteristic downward and lateral displacement of the scapula, with narrowing of the inferior scapulohumeral angle and loss of function, with pain commonly present. In all, 80 nerves were explored and 65 were repaired. The course of the spinal accessory nerve in relation to the sternocleidomastoid muscle was constant, with branches from the cervical plexus rarely conveying motor fibres. Damage to the nerve was predominantly posterior to this muscle. Despite the delay, the results of repair were surprising, with early relief of pain, implying a neuropathic source, which preceded generally good recovery of muscle function.
Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion <
30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe extra-articular contracture of the elbow. This retrospective study included 26 patients (15 males and 11 females) with a mean age of 30 years (12 to 60). The mean duration of stiffness was 9.1 months (5.4 to 18) with mean follow-up of 5.2 years (3.5 to 9.4). The mean pre-operative arc of movement was 15.6° (0° to 30°), with mean pre-operative flexion of 64.1° (30° to 120°) and mean pre-operative extension of 52.1° (10° to 90°). Post-operatively the mean arc improved to 102.4° (60° to 135°), the mean flexion improved to 119.1° (90° to 140°) and mean extension improved to 16.8° (0° to 30°) (p <
0.001). The Mayo elbow score improved from a mean of 45 (30 to 65) to 89 (75 to 100) points, and 13 had excellent, nine had good, three had fair and one had a poor result. We had one case of severe instability and one wound dehiscence which responded well to treatment. One case had deep infection with poor results which responded well to treatment. Our findings indicate that this method is very effective in the treatment of severe elbow contracture; however, a randomised controlled study is necessary for further evaluation.
We treated 32 displaced mallet finger fractures by a two extension block Kirschner-wire technique. The clinical and radiological outcomes were evaluated at a mean follow-up of 49 months (25 to 84). The mean joint surface involvement was 38.4% (33% to 50%) and 18 patients (56%) had accompanying joint subluxation. All 32 fractures united with a mean time to union of 6.2 weeks (5.1 to 8.2). Congruent joint surfaces and anatomical reduction were seen in all cases. The mean flexion of the distal interphalangeal joints was 83.1° (75° to 90°) and the mean extension loss was 0.9° (0° to 7°). No digit had a prominent dorsal bump or a recurrent mallet deformity. We believe that this technique, when properly applied, produces satisfactory results both clinically and radiologically.
We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared. The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group. We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.
Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components.
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.
We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with the further follow-up. A total of 23 patients (63%) had radiological evidence of loosening of the glenoid component. Nevertheless, only one patient had aseptic loosening of the baseplate at 12 years’ follow-up. The reduction in the mean Constant score with longer follow-up and the further development of scapular notching is worrying. New developments in design, bearing surfaces and surgical technique, and further follow-up, will determine whether reverse shoulder arthroplasty has a place in the management of complex proximal humeral fractures in the elderly.
There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.
We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components. Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt >
5° or subsidence >
5 mm), the presence of radiolucent lines and a Constant score of <
30 as the endpoints. There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of >
30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001). We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.
Linburg-Comstock syndrome is characterised by an anomalous tendon slip from the flexor pollicis longus to the flexor digitorum profundus, usually of the index finger. An incidence as high as 60% to 70% has been reported. Post-traumatic inflammation of inter-tendinous connections between the flexor pollicis longus and flexor digitorum profundus, usually of the index finger, may cause unexplained chronic pain in the distal forearm. A total of 11 patients (eight females, three males), mean age 29.1 years (14 to 47) with a clinical diagnosis of Linburg-Comstock syndrome underwent surgical release of the inter-tendinous connection. The mean follow-up was for 27 months (2 to 48). Ten patients reported excellent relief of pain in the forearm, with independent flexion of flexor pollicis longus and flexor digitorum profundus to the index finger. Surgical release was an effective treatment for the Linburg-Comstock syndrome in this series.
Advanced osteoarthritis of the wrist or the distal articulation of the lunate with the capitate has traditionally been treated surgically by arthrodesis. In order to maintain movement, we performed proximal row carpectomy with capsular interposition arthroplasty as an alternative to arthrodesis in eight patients with advanced arthritis and retrospectively reviewed their clinical and radiographic outcomes after a mean follow-up of 41 months (13 to 53). The visual analogue scale (VAS) for pain at its worst and at rest, and the patient-rated wrist evaluation score improved significantly after surgery, whereas ranges of movement and grip strength were maintained at the pre-operative levels. Progression of arthritis in the radiocapitate joint was observed in three patients, but their outcomes were not significantly different from those without progression of arthritis. Proximal row carpectomy with capsular interposition arthroplasty is a reasonable option for the treatment of patients with advanced arthritis of the wrist.
We evaluated 56 patients for neurological deficit after enucleation of a histopathologically confirmed schwannoma of the upper limb. Immediately after the operation, 41 patients (73.2%) had developed a new neurological deficit: ten of these had a major deficit such as severe motor or sensory loss, or intolerable neuropathic pain. The mean tumour size had been significantly larger in patients with a major neurological deficit than in those with a minor or no deficit. After a mean 25.4 months (12 to 85), 39 patients (70%) had no residual neurological deficit, and the other 17 (30%) had only hypoaesthesia, paraesthesiae or mild motor weakness. This study suggests that a schwannoma in the upper limb can be removed with an acceptable risk of injury to the nerve, although a transient neurological deficit occurs regularly after the operation. Biopsy is not advised. Patients should be informed pre-operatively about the possibility of damage to the nerve: meticulous dissection is required to minimise this.