Advertisement for orthosearch.org.uk
Results 1 - 35 of 35
Results per page:
Bone & Joint Research
Vol. 13, Issue 4 | Pages 169 - 183
15 Apr 2024
Gil-Melgosa L Llombart-Blanco R Extramiana L Lacave I Abizanda G Miranda E Agirre X Prósper F Pineda-Lucena A Pons-Villanueva J Pérez-Ruiz A

Aims

Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells.

Methods

HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential.


Bone & Joint Research
Vol. 13, Issue 9 | Pages 474 - 484
10 Sep 2024
Liu Y Li X Jiang L Ma J

Aims

Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration.

Methods

Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs.


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 541 - 545
1 May 2004
Takwale VJ Stanley JK Shahane SA

In 28 patients with a solitary diagnosis of instability of the trapeziometacarpal joint because of a rupture of the anterior oblique ligament, reconstruction was carried out using a slip of the tendon of flexor carpi radialis. We were able to review 26 patients. The results after a follow-up of four years seven months showed that most (87%) had significant relief from pain and symptoms. Seventeen were graded as good to excellent. The mean grip strength recovered to 86% of the contralateral side. Most patients (81%) felt that they had subjective improvement and would have undergone the operation again. A lesser functional result was seen in those who developed a flexion deformity because of overtightening of the reconstruction. Increased awareness of this lesion can lead to an early and clear diagnosis so that the patient may be advised adequately. We describe a specific, diagnostic, clinical test which we have used consistently and successfully


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives

Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting.

Methods

Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims

Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically.

Methods

Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 470 - 480
1 Oct 2016
Sabharwal S Patel NK Griffiths D Athanasiou T Gupte CM Reilly P

Objectives

The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes.

Methods

A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 175 - 177
1 May 2016
Rubin G Rinott M Wolovelsky A Rosenberg L Shoham Y Rozen N

Objectives

Injectable Bromelain Solution (IBS) is a modified investigational derivate of the medical grade bromelain-debriding pharmaceutical agent (NexoBrid) studied and approved for a rapid (four-hour single application), eschar-specific, deep burn debridement. We conducted an ex vivo study to determine the ability of IBS to dissolve-disrupt (enzymatic fasciotomy) Dupuytren’s cords.

Materials and Methods

Specially prepared medical grade IBS was injected into fresh Dupuytren’s cords excised from patients undergoing surgical fasciectomy. These cords were tested by tension-loading them to failure with the Zwick 1445 (Zwick GmbH & Co. KG, Ulm, Germany) tension testing system.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims

The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation.

Patients and Methods

We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control.

The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet.


Bone & Joint Research
Vol. 3, Issue 2 | Pages 38 - 47
1 Feb 2014
Hogendoorn S Duijnisveld BJ van Duinen SG Stoel BC van Dijk JG Fibbe WE Nelissen RGHH

Objectives

Traumatic brachial plexus injury causes severe functional impairment of the arm. Elbow flexion is often affected. Nerve surgery or tendon transfers provide the only means to obtain improved elbow flexion. Unfortunately, the functionality of the arm often remains insufficient. Stem cell therapy could potentially improve muscle strength and avoid muscle-tendon transfer. This pilot study assesses the safety and regenerative potential of autologous bone marrow-derived mononuclear cell injection in partially denervated biceps.

Methods

Nine brachial plexus patients with insufficient elbow flexion (i.e., partial denervation) received intramuscular escalating doses of autologous bone marrow-derived mononuclear cells, combined with tendon transfers. Effect parameters included biceps biopsies, motor unit analysis on needle electromyography and computerised muscle tomography, before and after cell therapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 132 - 139
1 Jul 2013
Ketola S Lehtinen J Rousi T Nissinen M Huhtala H Konttinen YT Arnala I

Objectives

To report the five-year results of a randomised controlled trial examining the effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome.

Methods

A total of 140 patients were randomly divided into two groups: 1) supervised exercise programme (n = 70, exercise group); and 2) arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group).


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 952 - 959
1 Jul 2013
Cai X Yan S Giddins G

Most patients with a nightstick fracture of the ulna are treated conservatively. Various techniques of immobilisation or early mobilisation have been studied. We performed a systematic review of all published randomised controlled trials and observational studies that have assessed the outcome of these fractures following above- or below-elbow immobilisation, bracing and early mobilisation. We searched multiple electronic databases, related bibliographies and other studies. We included 27 studies comprising 1629 fractures in the final analysis. The data relating to the time to radiological union and the rates of delayed union and nonunion could be pooled and analysed statistically.

We found that early mobilisation produced the shortest radiological time to union (mean 8.0 weeks) and the lowest mean rate of nonunion (0.6%). Fractures treated with above- or below-elbow immobilisation and braces had longer mean radiological times to union (9.2 weeks, 9.2 weeks and 8.7 weeks, respectively) and higher mean rates of nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically significant difference in the rate of non- or delayed union between those treated by early mobilisation and the three forms of immobilisation (p = 0.142 to p = 1.000, respectively). All the studies had significant biases, but until a robust randomised controlled trial is undertaken the best advice for the treatment of undisplaced or partially displaced nightstick fractures appears to be early mobilisation, with a removable forearm support for comfort as required.

Cite this article: Bone Joint J 2013;95-B:952–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1666 - 1669
1 Dec 2012
Gulotta LV Choi D Marinello P Wright T Cordasco FA Craig EV Warren RF

Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04).

Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (sd 14), which increased to 58 (sd 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019).

We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management.

Cite this article: Bone Joint J 2013;95-B:199–205.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1246 - 1252
1 Sep 2012
Penning LIF de Bie RA Walenkamp GHIM

A total of 159 patients (84 women and 75 men, mean age of 53 (20 to 87)) with subacromial impingement were randomised to treatment with subacromial injections using lidocaine with one of hyaluronic acid (51 patients), corticosteroid (53 patients) or placebo (55 patients). Patients were followed up for 26 weeks. The primary outcome was pain on a visual analogue score (VAS), and secondary outcomes included the Constant Murley score, shoulder pain score, functional mobility score, shoulder disability questionnaire and pain-specific disability score. The different outcome measures showed similar results. After three, six and 12 weeks corticosteroid injections were superior to hyaluronic acid injections and only at six weeks significantly better than placebo injections. The mean short-term reduction in pain on the VAS score at 12 weeks was 7% (sd 2.7; 97.5% confidence interval (CI) 0.207 to 1.55; p = 0.084) in the hyaluronic acid group, 28% (sd 2.8; 97.5% CI 1.86 to 3.65; p < 0.001) in the corticosteroid group and 23% (sd 3.23; 97.5% CI 1.25 to 3.26; p < 0.001) in the placebo group. At 26 weeks there was a reduction in pain in 63% (32 of 51) of patients in the hyaluronic acid group, 72% (38 of 53) of those in the corticosteroid group and 69% (38 of 55) of those in the placebo group.

We were not able to show a convincing benefit from hyaluronic acid injections compared with corticosteroid or placebo injections. Corticosteroid injections produced a significant reduction in pain in the short term (three to 12 weeks), but in the long term the placebo injection produced the best results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 77 - 82
1 Jan 2010
Karthikeyan S Kwong HT Upadhyay PK Parsons N Drew SJ Griffin D

We have carried out a prospective double-blind randomised controlled trial to compare the efficacy of a single subacromial injection of the non-steroidal anti-inflammatory drug, tenoxicam, with a single injection of methylprednisolone in patients with subacromial impingement. A total of 58 patients were randomly allocated into two groups. Group A received 40 mg of methylprednisolone and group B 20 mg of tenoxicam as a subacromial injection along with lignocaine. The Constant-Murley shoulder score was used as the primary outcome measure and the Disability of Arm, Shoulder and Hand (DASH) and the Oxford Shoulder Score (OSS) as secondary measures. Six weeks after injection the improvement in the Constant-Murley score was significantly greater in the methylprednisolone group (p = 0.003) than in the tenoxicam group. The improvement in the DASH score was greater in the steroid group and the difference was statistically significant and consistent two (p < 0.01), four (p < 0.01) and six weeks (p < 0.020) after the injection. The improvement in the OSS was consistently greater in the steroid group than in the tenoxicam group. Although the difference was statistically significant at two (p < 0.001) and four (p = 0.003) weeks after the injection, it was not at six weeks (p = 0.055). Subacromial injection of tenoxicam does not offer an equivalent outcome to subacromial injection of corticosteroid at six weeks. Corticosteroid is significantly better than tenoxicam for improving shoulder function in tendonitis of the rotator cuff after six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 498 - 502
1 Apr 2011
Gwilym SE Oag HCL Tracey I Carr AJ

Impingement syndrome in the shoulder has generally been considered to be a clinical condition of mechanical origin. However, anomalies exist between the pathology in the subacromial space and the degree of pain experienced. These may be explained by variations in the processing of nociceptive inputs between different patients. We investigated the evidence for augmented pain transmission (central sensitisation) in patients with impingement, and the relationship between pre-operative central sensitisation and the outcomes following arthroscopic subacromial decompression.

We recruited 17 patients with unilateral impingement of the shoulder and 17 age- and gender-matched controls, all of whom underwent quantitative sensory testing to detect thresholds for mechanical stimuli, distinctions between sharp and blunt punctate stimuli, and heat pain. Additionally Oxford shoulder scores to assess pain and function, and PainDETECT questionnaires to identify ‘neuropathic’ and referred symptoms were completed. Patients completed these questionnaires pre-operatively and three months post-operatively.

A significant proportion of patients awaiting subacromial decompression had referred pain radiating down the arm and had significant hyperalgesia to punctate stimulus of the skin compared with controls (unpaired t-test, p < 0.0001). These are felt to represent peripheral manifestations of augmented central pain processing (central sensitisation).

The presence of either hyperalgesia or referred pain pre-operatively resulted in a significantly worse outcome from decompression three months after surgery (unpaired t-test, p = 0.04 and p = 0.005, respectively).

These observations confirm the presence of central sensitisation in a proportion of patients with shoulder pain associated with impingement. Also, if patients had relatively high levels of central sensitisation pre-operatively, as indicated by higher levels of punctate hyperalgesia and/or referred pain, the outcome three months after subacromial decompression was significantly worse.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 208 - 212
1 Feb 2006
Habermeyer P Magosch P Rudolph T Lichtenberg S Liem D

We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42).

The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 811 - 816
1 Jun 2010
Robinson CM Akhtar MA Jenkins PJ Sharpe T Ray A Olabi B

Displaced fractures of the lateral end of the clavicle in young patients have a high incidence of nonunion and a poor functional outcome after conservative management. Operative treatment is therefore usually recommended. However, current techniques may be associated with complications which require removal of the fixation device. We have evaluated the functional and radiological outcomes using a novel technique of open reduction and internal fixation. A series of 16 patients under 60 years of age with displaced fractures of the lateral end were treated by open reduction and fixation using a twin coracoclavicular endobutton technique. They were followed up for the first year after their injury.

At one year the mean Constant score was 87.1 and the median Disabilities of the Arm, Shoulder and Hand score was 3.3. All fractures had united, except in one patient who developed an asymptomatic fibrous union. One patient had post-traumatic stiffness of the shoulder, which resolved with physiotherapy. None required re-operation.

This technique produces good functional and radiological outcomes with a low prevalence of complications and routine implant removal is not necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 918 - 921
1 Jul 2009
Finestone A Milgrom C Radeva-Petrova DR Rath E Barchilon V Beyth S Jaber S Safran O

We undertook a prospective study in 51 male patients aged between 17 and 27 years to ascertain whether immobilisation after primary traumatic anterior dislocation of the shoulder in external rotation was more effective than immobilisation in internal rotation in preventing recurrent dislocation in a physically active population.

Of the 51 patients, 24 were randomised to be treated by a traditional brace in internal rotation and 27 were immobilised in external rotation of 15° to 20°. After immobilisation, the patients undertook a standard regime of physiotherapy and were then assessed clinically for evidence of instability. When reviewed at a mean of 33.4 months (24 to 48) ten from the external rotation group (37%) and ten from the internal rotation group (41.7%) had sustained a futher dislocation. There was no statistically significant difference (p = 0.74) between the groups.

Our findings show that external rotation bracing may not be as effective as previously reported in preventing recurrent anterior dislocation of the shoulder.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 83 - 91
1 Jan 2010
Moosmayer S Lund G Seljom U Svege I Hennig T Tariq R Smith H

In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment.

Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p < 0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p < 0.0005).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 82 - 87
1 Jan 2009
Charalambous CP Stanley JK Siddique I Aster A Gagey O

The lateral ligament complex is the primary constraint to posterolateral rotatory laxity of the elbow, and if it is disrupted during surgery, posterolateral instability may ensue. The Wrightington approach to the head of the radius involves osteotomising the ulnar insertion of this ligament, rather than incising through it as in the classic posterolateral (Kocher) approach. In this biomechanical study of 17 human cadaver elbows, we demonstrate that the surgical approach to the head can influence posterolateral laxity, with the Wrightington approach producing less posterolateral rotatory laxity than the posterolateral approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 614 - 618
1 May 2008
Ruch DS Shen J Chloros GD Krings E Papadonikolakis A

Contracture of the collateral ligaments is considered to be an important factor in post-traumatic stiffness of the elbow. We reviewed the results of isolated release of the medial collateral ligament in a series of 14 patients with post-traumatic loss of elbow flexion treated between 1998 and 2002. There were nine women and five men with a mean age of 45 years (17 to 76). They were reviewed at a mean follow-up of 25 months (9 to 48). The operation was performed through a longitudinal posteromedial incision centred over the ulnar nerve. After decompression of the ulnar nerve, release of the medial collateral ligament was done sequentially starting with the posterior bundle and the transverse component of the ligament, with measurement of the arc of movement after each step. If full flexion was not achieved the posterior half of the anterior bundle of the medial collateral ligament was released.

At the latest follow-up, the mean flexion of the elbow improved significantly from 96° (85° to 115°) pre-operatively to 130° (110° to 150°) at final follow-up (p = 0.001). The mean extension improved significantly from 43° (5° to 90°) pre-operatively to 22° (5° to 40°) at final follow-up (p = 0.003). There was a significant improvement in the functional outcome. The mean Broberg and Morrey score increased from a mean of 54 points (29.5 to 85) pre-operatively to 87 points (57 to 99) at final follow-up (p < 0.001). All the patients had normal elbow stability.

Our results indicate that partial surgical release of the medial collateral ligament is associated with improved range of movement of the elbow in patients with post-traumatic stiffness, but was less effective in controlling pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 745 - 750
1 Jun 2008
Millar NL Murrell GAC

We identified ten patients who underwent arthroscopic revision of anterior shoulder stabilisation between 1999 and 2005. Their results were compared with 15 patients, matched for age and gender, who had a primary arthroscopic stabilisation during the same period.

At a mean follow-up of 37 and 36 months, respectively, the scores for pain and shoulder function improved significantly between the pre-operative and follow-up visits in both groups (p = 0.002), with no significant difference between them (p = 0.4). The UCLA and Rowe shoulder scores improved significantly (p = 0.004 and p = 0.002, respectively), with no statistically significant differences between groups (p = 0.6). Kaplan-Meier analysis for time to recurrent instability showed no differences between the groups (p = 0.2).

These results suggest that arthroscopic revision anterior shoulder stabilisation is as reliable as primary arthroscopic stabilisation for patients who have had previous open surgery for recurrent anterior instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 757 - 763
1 Jun 2008
Resch H Povacz P Maurer H Koller H Tauber M

After establishing anatomical feasibility, functional reconstruction to replace the anterolateral part of the deltoid was performed in 20 consecutive patients with irreversible deltoid paralysis using the sternoclavicular portion of the pectoralis major muscle. The indication for reconstruction was deltoid deficiency combined with massive rotator cuff tear in 11 patients, brachial plexus palsy in seven, and an isolated axillary nerve lesion in two. All patients were followed clinically and radiologically for a mean of 70 months (24 to 125). The mean gender-adjusted Constant score increased from 28% (15% to 54%) to 51% (19% to 83%). Forward elevation improved by a mean of 37°, abduction by 30° and external rotation by 9°.

The pectoralis inverse plasty may be used as a salvage procedure in irreversible deltoid deficiency, providing subjectively satisfying results. Active forward elevation and abduction can be significantly improved.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation.

We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour.

These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 345 - 350
1 Mar 2006
Loew M Heitkemper S Parsch D Schneider S Rickert M

We reviewed 39 patients with displaced three- and four-part fractures of the humerus. In 21 patients (group A) we had used an anatomical prosthesis for the humeral head and in 18 (group B) an implant designed for fractures.

When followed up at a mean of 29.3 months after surgery the overall Constant score was 51.9 points; in group A it was 51.5 and in group B 52.4 points. The subjective satisfaction of the patients was assessed using a numerical rating scale and was similar in both groups. In group A complete healing of the tuberosities was found in 29% and 50% in group B. Partial integration was seen in 29% of group A and in only one patient in group B, while resorption was noted in 43% of group A and 44% of group B. The functional outcome was significantly better in patients with complete or partial healing of the tuberosities (p = 0.022). The specific trauma prosthesis did not lead to better healing of the tuberosities. The difference in clinical outcome obtained by the two designs did not reach statistical significance.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1647 - 1652
1 Dec 2005
Shao YC Harwood P Grotz MRW Limb D Giannoudis PV

The management of radial nerve palsy associated with fractures of the shaft of the humerus has been disputed for several decades. This study has systematically reviewed the published evidence and developed an algorithm to guide management. We searched web-based databases for studies published in the past 40 years and identified further pages through manual searches of the bibliography in papers identified electronically. Of 391 papers identified initially, encompassing a total of 1045 patients with radial nerve palsy, 35 papers met all our criteria for eligibility. Meticulous extraction of the data was carried out according to a preset protocol.

The overall prevalence of radial nerve palsy after fracture of the shaft of the humerus in 21 papers was 11.8% (532 palsies in 4517 fractures). Fractures of the middle and middle-distal parts of the shaft had a significantly higher association with radial nerve palsy than those in other parts. Transverse and spiral fractures were more likely to be associated with radial nerve palsy than oblique and comminuted patterns of fracture (p < 0.001). The overall rate of recovery was 88.1% (921 of 1045), with spontaneous recovery reaching 70.7% (411 of 581) in patients treated conservatively. There was no significant difference in the final results when comparing groups which were initially managed expectantly with those explored early, suggesting that the initial expectant treatment did not affect the extent of nerve recovery adversely and would avoid many unnecessary operations. A treatment algorithm for the management of radial nerve palsy associated with fracture of the shaft of the humerus is recommended by the authors.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 819 - 823
1 Jun 2005
Boehm TD Werner A Radtke S Mueller T Kirschner S Gohlke F

In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used.

We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography.

Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% vs 92%; rate of further tear, 18% vs 22%; and revision, 4% vs 4%. In cases of further tear the outcome in group 2 did not differ from that for the intact repairs (91% vs 91%), but in group 1 it was significantly worse (94% vs 77%, p = 0.005).

Overall, seven patients had complications which required revision surgery, in four for pain (two in each group) and in three for infection (two in group 1 and one in group 2).