To assess the accuracy of patient-specific instruments (PSIs) CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s Objectives
Methods
Aims. Following the resection of an extensive amount of bone in the
treatment of a tumour, the residual segment may be insufficient
to accept a standard length intramedullary cemented stem. Short-stemmed
endoprostheses conceivably have an increased risk of aseptic loosening.
Extra-cortical plates have been added to minimise this risk by supplementing
fixation. The aim of this study was to investigate the survivorship
of short-stemmed endoprostheses and extra-cortical plates. Patients and Methods. The study involved 37 patients who underwent limb salvage surgery
for a primary neoplasm of bone between 1998 and 2013. Endoprosthetic
replacement involved the proximal humerus in nine, the proximal
femur in nine, the distal femur in 13 and the proximal tibia in
six patients. There were 12 primary (32%) and 25 revision procedures (68%).
Implant survivorship was compared with matched controls. The amount
of bone that was resected was >
70% of its length and statistically
greater than the standard control group at each anatomical site. Results. The mean follow-up was seven years (one to 17). The mean length
of the stem was 33 mm (20 to 60) in the humerus and 79 mm (34 to
100) in the lower limb. Kaplan-Meier analysis of survival of the
implant according to anatomical site confirmed that there was no
statistically significant difference between the short-stemmed endoprostheses and
the standard stemmed controls at the proximal humeral (p = 0.84),
proximal femoral (p = 0.57), distal femoral (p = 0.21) and proximal
tibial (p = 0.61) sites. In the short-stemmed group, no implants with extra-cortical plate
osseointegration suffered loosening at a mean of 8.5 years (range
2 to 16 years). Three of ten (30%) without osseointegration suffered
aseptic loosening at a mean of 7.7 years (range 2 to 11.5 years). Conclusion. When extensive
1. An operation to re-establish the continuity of the
The morphometry of the distal femur was largely studied to improve
bone-implant fit in total knee arthroplasty (TKA), but little is
known about the asymmetry of the posterior condyles. This study
aimed to investigate the dimensions of the posterior condyles and
the influence of externally rotating the femoral component on potential prosthetic
overhang or under-coverage. We analysed the shape of 110 arthritic knees at the time of primary
TKA using pre-operative CT scans. The height and width of each condyle
were measured at the posterior femoral cut in neutral position,
and in 3º and 5º of external rotation, using both central and medial
referencing systems. We compared the morphological characteristics
with those of 14 TKA models.Aims
Patients and Methods
Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions. Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.Objectives
Methods
After intercalary resection of a bone tumour from the femur,
reconstruction with a vascularized fibular graft (VFG) and massive
allograft is considered a reliable method of treatment. However,
little is known about the long-term outcome of this procedure. The
aims of this study were to determine whether the morbidity of this
procedure was comparable to that of other reconstructive techniques,
if it was possible to achieve a satisfactory functional result, and
whether biological reconstruction with a VFG and massive allograft
could achieve a durable, long-lasting reconstruction. A total of 23 patients with a mean age of 16 years (five to 40)
who had undergone resection of an intercalary bone tumour of the
femur and reconstruction with a VFG and allograft were reviewed
clinically and radiologically. The mean follow-up was 141 months
(24 to 313). The mean length of the fibular graft was 18 cm (12 to
29). Full weight-bearing without a brace was allowed after a mean
of 13 months (seven to 26).Aims
Patients and Methods
Because there have been no standard methods to determine pre-operatively
the thickness of resection of the proximal tibia in unicompartmental
knee arthroplasty (UKA), information about the relationship between
the change of limb alignment and the joint line elevation would
be useful for pre-operative planning. The purpose of this study
was to clarify the correlation between the change of limb alignment
and the change of joint line height at the medial compartment after
UKA. A consecutive series of 42 medial UKAs was reviewed retrospectively.
These patients were assessed radiographically both pre- and post-operatively
with standing anteroposterior radiographs. The thickness of bone
resection at the proximal tibia and the distal femur was measured
radiographically. The relationship between the change of femorotibial
angle (δFTA) and the change of joint line height, was analysed.Objectives
Methods
We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice.Objectives
Methods
The aims of this study were: firstly, to investigate the influence
of the thickness of cartilage at the sigmoid notch on the inclination
of the distal radioulnar joint (DRUJ), and secondly, to compare
the sensitivity and specificity of MRI with plain radiographs for
the assessment of the inclination of the articular surface of the
DRUJ in the coronal plane. Contemporaneous MRI images and radiographs of 100 wrists from
98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male,
53%) with no history of a fracture involving the wrist or surgery
to the wrist, were reviewed. The thickness of the cartilage at the
sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ
were determined. Aims
Patients and Methods
Collateral ligament release is advocated in total
knee arthroplasty (TKA) to deal with significant coronal plane deformities,
but is also associated with significant disadvantages. We describe steps to avoid release of the collateral (superficial
medial and lateral collateral) ligaments during TKA in severely
deformed knees, while correcting deformity and balancing the knee. Cite this article:
The aims of this study were to evaluate the clinical and radiological
outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients
with rheumatoid arthritis. This was a retrospective review of all 95 Universal-2 TWAs which
were performed in our institution between 2003 to 2012 in patients
with rheumatoid arthritis. A total of six patients were lost to
follow-up and two died of unrelated causes. A total of ten patients
had bilateral procedures. Accordingly, 75 patients (85 TWAs) were
included in the study. There were 59 women and 16 men with a mean
age of 59 years (26 to 86). The mean follow-up was 53 months (24
to 120). Clinical assessment involved recording pain on a visual
analogue score, range of movement, grip strength, the Quick Disabilities
of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores.
Any adverse effects were documented with particular emphasis on
residual pain, limitation of movement, infection, dislocation and
the need for revision surgery. Radiographic assessment was performed pre-operatively and at
three, six and 12 months post-operatively, and annually thereafter.
Arthroplasties were assessed for distal row intercarpal fusion and
loosening. Radiolucent zones around the components were documented
according to a system developed at our institution.Aims
Patients and Methods
The use of robotics in arthroplasty surgery is expanding rapidly as improvements in the technology evolve. This article examines current evidence to justify the usage of robotics, as well as the future potential in this emerging field.
Primary total knee arthroplasty (TKA) is a reliable
procedure with reproducible long-term results. Nevertheless, there
are conditions related to the type of patient or local conditions
of the knee that can make it a difficult procedure. The most common
scenarios that make it difficult are discussed in this review. These
include patients with many previous operations and incisions, and
those with severe coronal deformities, genu recurvatum, a stiff knee,
extra-articular deformities and those who have previously undergone
osteotomy around the knee and those with chronic dislocation of
the patella. Each condition is analysed according to the characteristics of
the patient, the pre-operative planning and the reported outcomes. When approaching the difficult primary TKA surgeons should use
a systematic approach, which begins with the review of the existing
literature for each specific clinical situation. Cite this article:
The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, Objectives
Methods
Few reports compare the contribution of the talonavicular articulation
to overall range of movement in the sagittal plane after total ankle
arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this
study was to assess changes in ROM and functional outcomes following
tibiotalar arthrodesis and TAA. Patients who underwent isolated tibiotalar arthrodesis or TAA
with greater than two-year follow-up were enrolled in the study.
Overall arc of movement and talonavicular movement in the sagittal
plane were assessed with weight-bearing lateral maximum dorsiflexion
and plantarflexion radiographs. All patients completed Short Form-12
version 2.0 questionnaires, visual analogue scale for pain (VAS)
scores, and the Foot and Ankle Ability Measure (FAAM).Aims
Patients and Methods
Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.Objectives
Methods