Advertisement for orthosearch.org.uk
Results 401 - 420 of 570
Results per page:
Bone & Joint Research
Vol. 3, Issue 2 | Pages 32 - 37
1 Feb 2014
Singh A Goel SC Gupta KK Kumar M Arun GR Patil H Kumaraswamy V Jha S

Introduction

Osteoarthritis (OA) is a progressively debilitating disease that affects mostly cartilage, with associated changes in the bone. The increasing incidence of OA and an ageing population, coupled with insufficient therapeutic choices, has led to focus on the potential of stem cells as a novel strategy for cartilage repair.

Methods

In this study, we used scaffold-free mesenchymal stem cells (MSCs) obtained from bone marrow in an experimental animal model of OA by direct intra-articular injection. MSCs were isolated from 2.8 kg white New Zealand rabbits. There were ten in the study group and ten in the control group. OA was induced by unilateral transection of the anterior cruciate ligament of the knee joint. At 12 weeks post-operatively, a single dose of 1 million cells suspended in 1 ml of medium was delivered to the injured knee by direct intra-articular injection. The control group received 1 ml of medium without cells. The knees were examined at 16 and 20 weeks following surgery. Repair was investigated radiologically, grossly and histologically using haematoxylin and eosin, Safranin-O and toluidine blue staining.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 662 - 665
1 May 2009
Brinker MR Loncarich DP Melissinos EG O’Connor DP

We report a case in which Ilizarov distraction osteogenesis was used to lengthen the portion of calcaneum that remained after a radical debridement for osteomyelitis. The patient was able to walk normally in unmodified shoes at the end of his treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 399 - 405
1 Mar 2014
Zang J Guo W Yang Y Xie L

We report our early experience with the use of a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction of the hemipelvis after resection of a primary malignant peri-acetabular tumour involving the sacroiliac joint.

We retrospectively reviewed the outcome of 17 patients who had undergone resection of a pelvic tumour and reconstruction with this prosthesis between July 2002 and July 2010.

One patient had a type I+II+III+IV resection (ilium + peri-acetabulum + pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium + acetabulum + sacrum). The outcome was assessed at a mean follow-up of 33 months (15 to 59). One patient was alive with disease, 11 were alive without disease and five had died of disease. The overall five-year survival rate was 62.4%. Six patients had a local recurrence. The mean Musculoskeletal Tumour Society score was 58% (33 to 77). Deep infection occurred in two patients, problems with wound healing in five and dislocation in one.

For patients with a primary malignant peri-acetabular sarcoma involving the sacroiliac joint, we believe that this new prosthesis is a viable option for reconstruction of the bony defect left following resection of the tumour. It results in a satisfactory functional outcome with an acceptable rate of complications.

Cite this article: Bone Joint J 2014;96-B:399–405.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 195 - 200
1 Feb 2014
Abolghasemian M Tangsaraporn S Drexler M Barbuto R Backstein D Safir O Kuzyk P Gross A

The use of ilioischial cage reconstruction for pelvic discontinuity has been replaced by the Trabecular Metal (Zimmer, Warsaw, Indiana) cup-cage technique in our institution, due to the unsatisfactory outcome of using a cage alone in this situation. We report the outcome of 26 pelvic discontinuities in 24 patients (20 women and four men, mean age 65 years (44 to 84)) treated by the cup-cage technique at a mean follow-up of 82 months (12 to 113) and compared them with a series of 19 pelvic discontinuities in 19 patients (18 women and one man, mean age 70 years (42 to 86)) treated with a cage at a mean follow-up of 69 months (1 to 170). The clinical and radiological outcomes as well as the survivorship of the groups were compared. In all, four of the cup-cage group (15%) and 13 (68%) of the cage group failed due to septic or aseptic loosening. The seven-year survivorship was 87.2% (95% confidence interval (CI) 71 to 103) for the cup-cage group and 49.9% (95% CI 15 to 84) for the cage-alone group (p = 0.009). There were four major complications in the cup-cage group and nine in the cage group. Radiological union of the discontinuity was found in all successful cases in the cup-cage group and three of the successful cage cases. Three hips in the cup-cage group developed early radiological migration of the components, which stabilised with a successful outcome.

Cup-cage reconstruction is a reliable technique for treating pelvic discontinuity in mid-term follow-up and is preferred to ilioischial cage reconstruction. If the continuity of the bone graft at the discontinuity site is not disrupted, early migration of the components does not necessarily result in failure.

Cite this article: Bone Joint J 2014;96-B:195–200.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 173 - 178
1 Feb 2006
de Jong PT Haverkamp D van der Vis HM Marti RK

We evaluated the long-term results of 116 total hip replacements with a superolateral shelfplasty in 102 patients with osteoarthritis secondary to developmental dysplasia of the hip. After a mean follow-up of 19.5 years (11.5 to 26.0), 14 acetabular components (12%) had been revised. The cumulative survival at 20 years was 78%, with revision for loosening of the acetabular component as the end-point. All grafts were well integrated and showed remodelling. In six grafts some resorption had occurred under the heads of the screws where the graft was not supporting the socket. Apart from these 14 revisions, seven acetabular components had possible radiological signs of loosening at a mean follow-up of 14.5 years, one had signs of probable loosening, and five had signs of definite loosening. These results indicate that this technique of bone grafting for acetabular reconstruction in hip dysplasia is a durable solution for cemented acetabular components.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated.

The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221).

The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°).

At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1617 - 1622
1 Dec 2008
Axelrad TW Steen B Lowenberg DW Creevy WR Einhorn TA

Heterotopic ossification occurring after the use of commercially available bone morphogenetic proteins has not been widely reported. We describe four cases of heterotopic ossification in patients treated with either recombinant bone morphogenetic protein 2 or recombinant bone morphogenetic protein 7. We found that while some patients were asymptomatic, heterotopic ossification which had occurred around a joint often required operative excision with good results.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 695 - 699
1 May 2011
Spiro AS Babin K Lipovac S Stenger P Mladenov K Rupprecht M Rueger JM Stuecker R

The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) for the treatment of congenital pseudarthrosis of the tibia has been investigated in only one previous study, with promising results. The aim of this study was to determine whether rhBMP-2 might improve the outcome of this disorder. We reviewed the medical records of five patients with a mean age of 7.4 years (2.3 to 21) with congenital pseudarthrosis of the tibia who had been treated with rhBMP-2 and intramedullary rodding. Ilizarov external fixation was also used in four of these patients. Radiological union of the pseudarthrosis was evident in all of them at a mean of 3.5 months (3.2 to 4) post-operatively. The Ilizarov device was removed after a mean of 4.2 months (3.0 to 5.3). These results indicate that treatment of congenital pseudarthrosis of the tibia using rhBMP-2 in combination with intramedullary stabilisation and Ilizarov external fixation may improve the initial rate of union and reduce the time to union.

Further studies with more patients and longer follow-up are necessary to determine whether this surgial procedure may significantly enhance the outcome of congenital pseudarthrosis of the tibia, considering the refracture rate (two of five patients) in this small case series.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1650 - 1655
1 Dec 2013
van Bergen CJA van Eekeren ICM Reilingh ML Sierevelt IN van Dijk CN

We have evaluated the clinical effectiveness of a metal resurfacing inlay implant for osteochondral defects of the medial talar dome after failed previous surgical treatment. We prospectively studied 20 consecutive patients with a mean age of 38 years (20 to 60), for a mean of three years (2 to 5) post-surgery. There was statistically significant reduction of pain in each of four situations (i.e., rest, walking, stair climbing and running; p ≤ 0.01). The median American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 62 (interquartile range (IQR) 46 to 72) pre-operatively to 87 (IQR 75 to 95) at final follow-up (p < 0.001). The Foot and Ankle Outcome Score improved on all subscales (p ≤ 0.03). The mean Short-Form 36 physical component scale improved from 36 (23 to 50) pre-operatively to 45 (29 to 55) at final follow-up (p = 0.001); the mental component scale did not change significantly. On radiographs, progressive degenerative changes of the opposing tibial plafond were observed in two patients. One patient required additional surgery for the osteochondral defect. This study shows that a metal implant is a promising treatment for osteochondral defects of the medial talar dome after failed previous surgery.

Cite this article: Bone Joint J 2013;95-B:1650–5.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 29 - 31
1 Aug 2013

The August 2013 Research Roundup360 looks at: passive smoking and bone substitutes; platelet-rich plasma and osteogenesis; plantar fasciitis and platelet-rich plasma: a match made in heaven?; MRSA decolonisation decreases infection rates; gums, bisphosphonates and orthopaedics; PRAISE and partner violence; blunt impact and post-traumatic OA; and IDEAL research and implants


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1309 - 1319
1 Oct 2005
Hall S


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 153 - 158
1 Nov 2013
Victor J Premanathan A

We have investigated the benefits of patient specific instrument guides, applied to osteotomies around the knee. Single, dual and triple planar osteotomies were performed on tibias or femurs in 14 subjects. In all patients, a detailed pre-operative plan was prepared based upon full leg standing radiographic and CT scan information. The planned level of the osteotomy and open wedge resection was relayed to the surgery by virtue of a patient specific guide developed from the images. The mean deviation between the planned wedge angle and the executed wedge angle was 0° (-1 to 1, sd 0.71) in the coronal plane and 0.3° (-0.9 to 3, sd 1.14) in the sagittal plane. The mean deviation between the planned hip, knee, ankle angle (HKA) on full leg standing radiograph and the post-operative HKA was 0.3° (-1 to 2, sd 0.75). It is concluded that this is a feasible and valuable concept from the standpoint of pre-operative software based planning, surgical application and geometrical accuracy of outcome.

Cite this article: Bone Joint J 2013;95-B, Supple A:153–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 995 - 999
1 Aug 2008
Longo UG King JB Denaro V Maffulli N

There is a trend towards the use of double-bundle techniques for the reconstruction of the anterior cruciate ligament. This has not been substantiated scientifically. The functional outcome of these techniques is equivalent to that of single-bundle methods. The main advantage of a double-bundle rather than a single-bundle reconstruction should be a better rotational stability, but the validity and accuracy of systems for the measurement of rotational stability have not been confirmed.

Despite the enthusiasm of surgeons for the double-bundle technique, reconstruction with a single-bundle should remain the standard method for managing deficiency of the anterior cruciate ligament until strong evidence in favour of the use of the double-bundle method is available.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 25 - 27
1 Jun 2013

The June 2013 Wrist & Hand Roundup360 looks at: whether size is a limitation; cancellous bone grafting in scaphoid nonunion; the Kienböck’s dichotomy; late displacement of the distal radius; flexor slide for finger contracture; aesthetic syndactyly; flexor tendon repair; and fixation of trapeziometacarpal cups.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 807 - 816
1 Jun 2014
Rajaee SS Kanim LEA Bae HW

Using the United States Nationwide Inpatient Sample, we identified national trends in revision spinal fusion along with a comprehensive comparison of comorbidities, inpatient complications and surgical factors of revision spinal fusion compared to primary spinal fusion.

In 2009, there were 410 158 primary spinal fusion discharges and 22 128 revision spinal fusion discharges. Between 2002 and 2009, primary fusion increased at a higher rate compared with revision fusion (56.4% vs 51.0%; p < 0.001). In 2009, the mean length of stay and hospital charges were higher for revision fusion discharges than for primary fusion discharges (4.2 days vs 3.8 days, p < 0.001; USD $91 909 vs. $87 161, p < 0.001). In 2009, recombinant human bone morphogenetic protein (BMP) was used more in revision fusion than in primary fusion (39.6% vs 27.6%, p < 0.001), whereas interbody devices were used less in revision fusion (41.8% vs 56.6%, p < 0.001).

In the multivariable logistic regression model for all spinal fusions, depression (odds ratio (OR) 1.53, p < 0.001), psychotic disorders (OR 1.49, p < 0.001), deficiency anaemias (OR 1.35, p < 0.001) and smoking (OR 1.10, p = 0.006) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges, adjusting for other variables. In terms of complications, after adjusting for all significant comorbidities, this study found that dural tears (OR 1.41; p < 0.001) and surgical site infections (OR 3.40; p < 0.001) had a greater chance of occurrence in revision spinal fusion discharges than in primary fusion discharges (p < 0.001). A p-value < 0.01 was considered significant in all final analyses.

Cite this article: Bone Joint J 2014;96-B:807–16.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)).

At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed.

No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks.

This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation.

Cite this article: Bone Joint J 2013;95-B:1514–20.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 820 - 824
1 Jun 2013
Zsoldos CM Basamania CJ Bal GK

Gunshot injuries to the shoulder are rare and difficult to manage. We present a case series of seven patients who sustained a severe shoulder injury to the non-dominant side as a result of a self-inflicted gunshot wound. We describe the injury as ‘suicide shoulder’ caused by upward and outward movement of the gun barrel as the trigger is pulled. All patients were male, with a mean age of 32 years (21 to 48). All were treated at the time of injury with initial repeated debridement, and within four weeks either by hemiarthroplasty (four patients) or arthrodesis (three patients). The hemiarthroplasty failed in one patient after 20 years due to infection and an arthrodesis was attempted, which also failed due to infection. Overall follow-up was for a mean of 26 months (12 to 44). All four hemiarthroplasty implants were removed with no feasible reconstruction ultimately possible, resulting in a poor functional outcome and no return to work. In contrast, all three primary arthrodeses eventually united, with two patients requiring revision plating and grafting. These patients returned to work with a good functional outcome. We recommend arthrodesis rather than replacement as the treatment of choice for this challenging injury.

Cite this article: Bone Joint J 2013;95-B:820–4.