Advertisement for orthosearch.org.uk
Results 361 - 380 of 2258
Results per page:
Bone & Joint 360
Vol. 8, Issue 1 | Pages 10 - 12
1 Feb 2019


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 288 - 296
1 Mar 2019
Sigmund IK Holinka J Sevelda F Staats K Heisinger S Kubista B McNally MA Windhager R

Aims

This study aimed to assess the performance of an automated multiplex polymerase chain reaction (mPCR) technique for rapid diagnosis of native joint septic arthritis

Patients and Methods

Consecutive patients with suspected septic arthritis undergoing aseptic diagnostic joint aspiration were included. The aspirate was used for analysis by mPCR and conventional microbiological analysis. A joint was classed as septic according to modified Newman criteria. Based on receiver operating characteristic (ROC) analysis, the area under the ROC curve (AUC) values of the mPCR and the synovial fluid culture were compared using the z-test. A total of 72 out of 76 consecutive patients (33 women, 39 men; mean age 64 years (22 to 92)) with suspected septic arthritis were included in this study.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1041 - 1046
1 Sep 2004
Porter DE Lonie L Fraser M Dobson-Stone C Porter JR Monaco AP Simpson AHRW

We performed a prospective genotype-phenotype study using molecular screening and clinical assessment to compare the severity of disease and the risk of sarcoma in 172 individuals (78 families) with hereditary multiple exostoses. We calculated the severity of disease including stature, number of exostoses, number of surgical procedures that were necessary, deformity and functional parameters and used molecular techniques to identify the genetic mutations in affected individuals. Each arm of the genotype-phenotype study was blind to the outcome of the other. Mutations EXT1 and EXT2 were almost equally common, and were identified in 83% of individuals. Non-parametric statistical tests were used. There was a wide variation in the severity of disease. Children under ten years of age had fewer exostoses, consistent with the known age-related penetrance of this condition. The severity of the disease did not differ significantly with gender and was very variable within any given family. The sites of mutation affected the severity of disease with patients with EXT1 mutations having a significantly worse condition than those with EXT2 mutations in three of five parameters of severity (stature, deformity and functional parameters). A single sarcoma developed in an EXT2 mutation carrier, compared with seven in EXT1 mutation carriers. There was no evidence that sarcomas arose more commonly in families in whom the disease was more severe. The sarcoma risk in EXT1 carriers is similar to the risk of breast cancer in an older population subjected to breast-screening, suggesting that a role for regular screening in patients with hereditary multiple exostoses is justifiable


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 366 - 370
1 May 1997
Simank H Brocai DRC Reiser D Thomsen M Sabo D Lukoschek M

We report our results using three different threaded acetabular components (Mecring A, Mecring B and Weill) in 715 hips with a follow-up of between one and ten years (median: 99.1, 56.5, 38.3 months, respectively). All cups were implanted with one type of cementless stem. The clinical results were good or acceptable in about 70% of the hips, but signs of loosening with radiolucency and/or migration were found in 10.1%. Radiological evidence of loosening did not correlate significantly with the clinical outcome. Pain was not a reliable indicator of loosening and its absence sometimes allowed severe osteolysis to develop. Twenty-five hips were revised (3.5%) for aseptic loosening of the acetabular component. Kaplan-Meier estimates of the cumulative rate of failure showed a rapid increase five years after the initial operation, but no significant correlation with gender, age or weight. The high rate of failure indicates that further use of these acetabular components cannot be recommended. Annual radiographs are required to assess osteolysis even if the patients are free from pain


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1310 - 1319
1 Oct 2018
Langton DJ Wells SR Joyce TJ Bowsher JG Deehan D Green S Nargol AVF Holland JP

Aims

There are limited published data detailing the volumetric material loss from tapers of conventional metal-on-polyethylene (MoP) total hip arthroplasties (THAs). Our aim was to address this by comparing the taper wear rates measured in an explanted cohort of the widely used Exeter THA with those measured in a group of metal-on-metal (MoM) THAs.

Patients and Methods

We examined an existing retrieval database to identify all Exeter V40 and Universal MoP THAs. Volumetric wear analysis of the taper surfaces was conducted using previously validated methodology. These values were compared with those obtained from a series of MoM THAs using non-parametric statistical methodology. A number of patient and device variables were accounted for using multiple regression modelling.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 93 - 97
1 Jan 1995
Ostermann P Seligson D Henry S

We reviewed 1085 consecutive compound limb fractures treated in 914 patients at the University of Louisville over a nine-year period. Of these fractures, 240 (group 1) received only systemic antibiotic prophylaxis and 845 (group 2) were managed by the supplementary local use of aminoglycoside-polymethylmethacrylate (PMMA) beads. There were no significant differences in age, gender, fracture type, fracture location or follow-up between the two groups. All had copious wound irrigation, meticulous debridement and skeletal stabilisation, but wound management and the use of local antibiotic depended on the surgeon's individual preference and there was no randomisation. In group 1 there was an overall infection rate of 12% as against 3.7% in group 2 (p < 0.001). Both acute infection and local osteomyelitis showed a decreased incidence in group 2, but this was statistically significant only in Gustilo type-IIIB and type-IIIC fractures for acute infection, and only in type-II and type-IIIB fractures for chronic osteomyelitis. Our review suggests that the adjuvant use of local antibiotic-laden PMMA beads may reduce the incidence of infection in severe compound fractures


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 221 - 226
1 Feb 2019
Ryan SP DiLallo M Klement MR Luzzi AJ Chen AF Seyler TM

Aims

The aim of this study was to characterize the factors leading to transfemoral amputation after total knee arthroplasty (TKA), as well as the rates of mortality and functional independence after this procedure in these patients.

Patients and Methods

This was a multicentre retrospective review with a prospective telephone survey for the assessment of function. All patients with a TKA who subsequently required transfemoral amputation between January 2001 and December 2015 were included. Demographic information, medical comorbidities, and postoperative mortality data were collected. A 19-item survey was used for the assessment of function in surviving patients.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 140 - 146
1 Feb 2019
Humphrey JA Woods A Robinson AHN

Aims

This paper documents the epidemiology of adults (aged more than 18 years) with a calcaneal fracture who have been admitted to hospital in England since 2000. Secondary aims were to document whether publication of the United Kingdom Heel Fracture Trial (UK HeFT) influenced the proportion of patients admitted to hospital with a calcaneal fracture who underwent surgical treatment, and to determine whether there has been any recent change in the surgical technique used for these injuries.

Patients and Methods

In England, the Hospital Episode Statistics (HES) data are recorded annually. Between 2000/01 and 2016/17, the number of adults admitted to an English NHS hospital with a calcaneal fracture and whether they underwent surgical treatment was determined.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1463 - 1470
1 Nov 2018
Murphy BPD Dowsey MM Spelman T Choong PFM

Aims

As the population ages, there is projected to be an increase in the level of demand for total knee arthroplasty (TKA) in octogenarians. We aimed to explore whether those aged ≥ 80 years achieved similar improvements in physical function to younger patients while also comparing the rates of length of stay (LOS), discharge to rehabilitation, postoperative complications, and mortality following TKA in older and younger patients.

Patients and Methods

Patients from one institution who underwent primary elective TKA between 1 January 2006 and 31 December 2014 were dichotomized into those ≥ 80 years old (n = 359) and those < 80 years old (n = 2479) for comparison. Multivariable regression was used to compare the physical status component of the 12-Item Short-Form Health Survey (SF-12), LOS, discharge to rehabilitation, complications, and mortality between the two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 875 - 880
1 Nov 1995
Koo K Kim R

In a randomised trial comparing core decompression with conservative treatment we tested the hypothesis that the extent of necrosis at the initial MRI predicts the subsequent risk of collapse of the femoral head. After the initial clinical evaluation, including plain radiography and MRI, 37 hips with early-stage osteonecrosis (ON) in 33 patients were randomly assigned to a core-decompression group or a conservatively-treated group. All were followed regularly by clinical evaluation, plain radiography and MRI at intervals of three months. The extent of ON was estimated on the basis of abnormal signal intensity in the weight-bearing portion of the femoral head as determined from a combination of coronal and sagittal MRIs. The arc of the necrotic portion in the mid-coronal image (A) and that in the mid-sagittal image (B) were used to quantify the extent of necrosis by the formula: (A/180) x (B/180) x 100. There was a strong correlation between this index and the risk of collapse before and after adjustment for age, gender, stage and treatment group. We conclude that the extent of the necrotic portion ascertain by this method is a major predictor of future collapse. We propose a systematic method of determining the index of the necrotic portion which may be clinically useful in the management of early-stage ON of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 249 - 253
1 Mar 1993
Cates H Faris P Keating E Ritter M

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The mean volumetric wear rate was 66.2 mm3/yr in the metal-backed sockets and 48.2 mm3/yr in the polyethylene sockets (p = 0.0002). The addition of metal backing to a cemented acetabular cup therefore resulted in a 37% increase in mean polyethylene wear rates which may partially explain the higher failure rate of cemented metal-backed cups. Linear regression analysis also implicated increased follow-up time (log), gross acetabular migration, metal backing and male gender in increasing polyethylene wear. We advocate the use of an all-polyethylene cup in cemented total hip arthroplasty. The increased polyethylene wear must also cause concern about the wear rate of uncemented metal-backed acetabular sockets


Bone & Joint Research
Vol. 7, Issue 11 | Pages 595 - 600
1 Nov 2018
Bergiers S Hothi HS Henckel J Eskelinen A Skinner J Hart A

Objectives

Previous studies have suggested that metal-on-metal (MoM) Pinnacle (DePuy Synthes, Warsaw, Indiana) hip arthroplasties implanted after 2006 exhibit higher failure rates. This was attributed to the production of implants with reduced diametrical clearances between their bearing surfaces, which, it was speculated, were outside manufacturing tolerances. This study aimed to better understand the performance of Pinnacle Systems manufactured before and after this event.

Methods

A total of 92 retrieved MoM Pinnacle hips were analyzed, of which 45 were implanted before 2007, and 47 from 2007 onwards. The ‘pre-2007’ group contained 45 implants retrieved from 21 male and 24 female patients, with a median age of 61.3 years (interquartile range (IQR) 57.1 to 65.5); the ‘2007 onwards’ group contained 47 implants retrieved from 19 male and 28 female patients, with a median age of 61.8 years (IQR 58.5 to 67.8). The volume of material lost from their bearing and taper surfaces was measured using coordinate and roundness measuring machines. These outcomes were then compared statistically using linear regression models, adjusting for potentially confounding factors.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1506 - 1510
1 Nov 2018
Parker B Petrou S Masters JPM Achana F Costa ML

Aims

The aim of this study was to estimate economic outcomes associated with deep surgical site infection (SSI) in patients with an open fracture of the lower limb.

Patients and Methods

A total of 460 patients were recruited from 24 specialist trauma hospitals in the United Kingdom Major Trauma Network. Preference-based health-related quality-of-life outcomes, assessed using the EuroQol EQ-5D-3L and the 6-Item Short-Form Health Survey questionnaire (SF-6D), and economic costs (£, 2014/2015 prices) were measured using participant-completed questionnaires over the 12 months following injury. Descriptive statistics and multivariate regression analysis were used to explore the relationship between deep SSI and health utility scores, quality-adjusted life-years (QALYs), and health and personal social service (PSS) costs.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1377 - 1384
1 Oct 2018
Ottesen TD McLynn RP Galivanche AR Bagi PS Zogg CK Rubin LE Grauer JN

Aims

The aims of this study were to evaluate the incidence of postoperatively restricted weight-bearing and its association with outcome in patients who undergo surgery for a fracture of the hip.

Patients and Methods

Patient aged > 60 years undergoing surgery for a hip fracture were identified in the 2016 National Surgical Quality Improvement Program (NSQIP) Hip Fracture Targeted Procedure Dataset. Analysis of the effect of restricted weight-bearing on adverse events, delirium, infection, transfusion, length of stay, return to the operating theatre, readmission and mortality within 30 days postoperatively were assessed. Multivariate regression analysis was used to adjust for confounding demographic, comorbid and procedural characteristics.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 361 - 365
1 May 1997
Shih C Lee P Chen J Tai C Chen L Wu JS Chang WH

We made a clinical study of polyethylene wear in 240 hips of 187 patients having primary total hip arthroplasties from 1989 to 1990, using uncemented Osteonics components, with a head size of 26 mm. We excluded cups with anteversion of over 20° and measured linear wear by a new method using a digitiser and special software of our design. Follow-up was from two to five years (mean 4.3). The mean age at operation was 50.3 years, with more men than women (1.4:1). The mean linear wear per year was 0.15 mm; this did not increase with the longevity of the prosthesis (p = 0.54). In 59 hips showing evidence of osteolysis, the mean linear wear rate was significantly higher at 0.23 mm/year (p < 0.001). The mean linear wear rate also correlated significantly with age at the time of operation (p = 0.008), but we found no significant correlations with body-weight, gender, aetiology of the disease, thickness of polyethylene, or cup position. Our new method of measurement is time-saving and reproducible. The results confirm the greater rate of linear wear of polyethylene in patients showing osteolysis and in those who are younger


Bone & Joint 360
Vol. 7, Issue 6 | Pages 12 - 15
1 Dec 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 351 - 355
1 Apr 2002
Ridgeway SR McAuley JP Ammeen DJ Engh GA

Many authors have recommended undercorrection of the deformity when carrying out unicompartmental knee arthroplasty (UKA). The isolated effect of alignment of the knee on the outcome of UKA has, however, received little attention. We reviewed 185 UKAs at a minimum of five years after surgery. They had been carried out by a single surgeon using metal-backed tibial components in the management of arthritis of the medial compartment. We measured the tibiofemoral angle (TFA) before and at four months after operation and at the most recent assessment. The amount of correction of the TFA and any subsequent loss were recorded. While adjusting for the effects of age, weight and gender of the patients and the type and thickness of the implants, the mean correction was significantly less for those with a Marmor rating of failure (6.8°) than for those rated excellent (9.2°). The mean correction was also significantly less for patients with a Marmor rating of failure (6.8°) than for those rated poor (11.1°). The mean correction for the UKAs which were revised (6.6°) was significantly less than for those not revised (9.1°). Additionally, revised UKAs had a significantly higher percentage (63%) of thinner tibial implants (< 8 mm) than the surviving UKAs (27%). These findings suggest that undercorrection of the TFA in UKA of the medial compartment should be avoided, particularly if a thin tibial polyethylene insert is used


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 162 - 169
1 Feb 2019
Catagni MA Azzam W Guerreschi F Lovisetti L Poli P Khan MS Di Giacomo LM

Aims

Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated.

Patients and Methods

A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).


Bone & Joint 360
Vol. 7, Issue 5 | Pages 21 - 24
1 Oct 2018