Advertisement for orthosearch.org.uk
Results 281 - 300 of 616
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 972 - 976
1 Sep 2000
Wakefield AE McQueen MM

The capacity for physiotherapy to improve the outcome after fracture of the distal radius is unproven. We carried out a randomised controlled trial on 96 patients, comparing conventional physiotherapy with a regime of home exercises. The function of the upper limb was assessed at the time of removal of the plaster cast and at three and six months after injury. Factors which may predict poor outcome in these patients were sought. Grip strength and hand function did not significantly differ between the two groups. Flexion and extension of the wrist were the only movements to improve with physiotherapy at six months (p = 0.001). Predictors of poor functional outcome were malunion and impaired function before the fracture. These patients presented with pain, decreased rotation of the forearm and low functional scores at six weeks. Our study has shown that home exercises are adequate rehabilitation after uncomplicated fracture of the distal radius, and routine referral for a course of physiotherapy should be discouraged. The role of physiotherapy in patients at high risk of a poor outcome requires further investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 346 - 349
1 May 1983
Scotland T Galway H

A long-term review of 131 children fitted with upper limb prostheses at the Ontario Crippled Children's Centre between 1965 and 1975 is reported. There were 116 children with congenital deficiencies and 15 who had had amputations. Follow-up ranged from 7 to 17 years. A total of 42 children had abandoned their prostheses, 37 of whom had congenital deformities and five were amputees. The level of deficiency was of fundamental importance in determining whether the prosthesis would be accepted; in the forearm, the longer the stump, the more likely it was that the child would discard the prosthesis. Overall, 50 per cent of children fitted over the age of two years abandoned their prostheses compared with only 22 per cent of patients who had been fitted before the age of two years. The highest drop-out rate was at the age of 13 years when the children became more conscious of their cosmetic appearance. Suggestions for reducing the high drop-out rate in the early teens are put forward


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 429 - 439
1 Aug 1971
Jones ERL Esah M

1. Thirty-four cases of displaced fracture of the neck of the radius in children are reviewed with special reference to elbow and forearm function. 2. There were eight poor functional results-four after eighteen closed reductions and four after sixteen open reductions. 3. The causes of the poor functional results are recorded and the complications discussed. Union in a displaced position was the main cause of restricted movement. Deformity of the radial head due to avascular necrosis, and fibrous adhesions between the neck of the radius and the ulna, were other factors. 4. Fractures that were held reduced by Kirschner wires had better results than comparable fractures treated by closed reduction or op en reduction without fixation. 5. It is concluded that all fractures, whatever the age of the child, with angular displacement exceeding 15 degrees need accurate reduction. Closed reduction is not easy, and repeated check radiographs are needed to ensure maintenance of reduction. Certain of these fractures are unstable and require internal fixation with Kirschner wires


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1173 - 1175
1 Nov 2001
Davidson JS Brown DJ Barnes SN Bruce CE

Torus (buckle) fractures of the distal radius are common in childhood. Based on the results of a postal questionnaire and a prospective, randomised trial, we describe a simple treatment for this injury, which saves both time and money. Over a six-month period, we randomised 201 consecutive patients with this injury to treatment with either a traditional forearm plaster-of-Paris cast or a ‘Futura-type’ wrist splint. All patients were treated for a period of three weeks, followed by clinical and radiological review. There was no difference in outcome between the two groups, and all patients had a good result. Only one patient did not tolerate the splint which was replaced by a cast. The questionnaire showed a marked variation in the way in which these injuries are treated with regard to the method and period of immobilisation, the number of follow-up visits and radiographs taken. We suggest that a ‘Futura-type’ wrist splint can be used to treat these fractures. The patient should be reviewed on the following day to confirm the diagnosis and to give appropriate advice. There is no evidence that further follow-up is required. This simple treatment has major benefits in terms of cost and reduction of the number of attendances


Bone & Joint 360
Vol. 9, Issue 1 | Pages 28 - 32
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 967 - 970
1 Sep 2002
Karnezis IA Fragkiadakis EG

Although the outcome of fractures of the distal radius is traditionally assessed using objective clinical variables such as grip strength and range of movement of the wrist, the extent to which they reflect function and outcomes of importance for the patient is uncertain. This may cause considerable inconsistencies in the assessment of outcome using current scoring systems. We prospectively studied 31 patients recovering from unstable fractures of the distal radius in order to investigate the association between objective variables and the level of post-traumatic disability of the wrist as measured by the patient-rated wrist evaluation (PRWE) score. Multiple regression showed considerable differences in the extent to which limitations in specific objective clinical variables reflected the level of disability of the wrist. Grip strength was shown to be a significant predictor of the PRWE score (regression coefficient −1.09, 95% confidence interval −1.76 to −0.42, p < 0.01) and thus appears to be a sensitive indicator of return of function of the wrist. Forearm rotation and flexion and extension of the wrist were not significantly associated with the PRWE score. These observations should be taken into account during the evaluation of methods of treatment and in constructing future clinical outcome scoring systems


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 749 - 753
1 Nov 1984
Stewart H Innes A Burke F

The use of Orthoplast cast-bracing to allow early hand function in the treatment of displaced Colles' fractures was investigated in 243 patients. They were randomly allocated into three groups: in the first a conventional Colles' type plaster was used; in the second an above-elbow cast-brace with the forearm in supination; and in the third a below-elbow cast-brace. Radiographic measurements were made at each stage of treatment, and the final anatomical result was scored using Sarmiento's (1975) criteria. Function was assessed at three months and at six months. The anatomical result was not influenced by the method of immobilisation but was related to the efficacy of reduction. Loss of position in the braces was no greater than in plaster. The functional result at three months also was uninfluenced by the method of immobilisation; it was, however, related to the severity of the initial displacement, and (to a lesser degree) to the anatomical result, an effect which was lost at six months. Early hand function and the supinated position advocated by Sarmiento were found to confer no anatomical or functional advantage; we could see no reason to change from the use of conventional plaster casts in the treatment of uncomplicated Colles' fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 213 - 221
1 May 1977
Roberts P Price C

Nineteen chondrosarcomas are reported arising in proximal phalanges or metacarpal bones of the hand mainly in elderly patients, predominantly women. The usual clinical presentation was of a progressively painful large tumour, often arising in a dormant lesion near the metacarpo-phalangeal joint. Radiologically most showed some bone expansion with a poorly defined area of destruction and a considerable soft-tissue swelling. Histologically, malignancy was usually obvious, but confusion might arise from the inclusion of bland areas of chondromatous tissue that probably represented the original lesion. Four tumours, initially curetted and grafted, recurred locally and necessitated amputation of the digit or ray. Amputation was the primary treatment for fourteen other tumours and was curative except in one patient who eventually needed amputation through the forearm for a large second recurrence. One tumour was satisfactorily controlled by excision of the affected phalanx. None of these nineteen tumours is known to have metastasised. Correct treatment implies a carefully considered balance between conservation of function and complete removal of all tumour tissue


Introduction

Virtual fracture clinics (VFCs) are being increasingly used to offer safe and efficient orthopaedic review without the requirement for face-to-face contact. With the onset of the COVID-19 pandemic, we sought to develop an online referral pathway that would allow us to provide definitive orthopaedic management plans and reduce face-to-face contact at the fracture clinics.

Methods

All patients presenting to the emergency department from 21March 2020 with a musculoskeletal injury or potential musculoskeletal infection deemed to require orthopaedic input were discussed using a secure messaging app. A definitive management plan was communicated by an on-call senior orthopaedic decision-maker. We analyzed the time to decision, if further information was needed, and the referral outcome. An analysis of the orthopaedic referrals for the same period in 2019 was also performed as a comparison.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims

The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up.

Patients and Methods

A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 918 - 923
1 Nov 1997
Gendi NST Axon JMC Carr AJ Pile KD Burge PD Mowat AG

We carried out a survival analysis of elbow synovectomy (ES) and excision of the radial head (RHE) performed on 171 rheumatoid elbows. The failure criteria were revision surgery (performed or desired) and/or the presence of significant or severe pain. The cumulative survival was 81% at one year which thereafter decreased by an average of 2.6% per year. The strongest predictor for success was a low preoperative range of supination-pronation when corresponding survival curves were compared. A low range of flexion-extension also predicted failure. Combining both factors gave better prediction (failure: 6.3% v 67%), but a long duration of elbow symptoms before surgery predicted failure (72%, p = 0.04). At review, there was a mean gain of 50° in supination-pronation and 11° in flexion-extension; both correlated with success. Failure correlated with recurrence of synovitis, elbow instability, ulnar neuropathy, poor general mobility and poor upper-limb function. The last was independently affected by the severity of RA in the ipsilateral shoulder. Our findings show that although the short-term result of ES and RHE in rheumatoid arthritis is good, the long-term outcome is poor except in a subgroup with more than 50% limitation of forearm rotation


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 904 - 911
1 Jul 2020
Sigmund IK Dudareva M Watts D Morgenstern M Athanasou NA McNally MA

Aims

The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition.

Methods

A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 964 - 964
1 Nov 1962

Professor Paul Brand draws attention to an error in the report of a meeting of the Orthopaedic Section of the Association of Surgeons of India submitted to this journal and published in our issue of May 1962. The observations then reported were not made by him but in his absence by another contributor. The particular paragraph to which Professor Brand wishes to draw attention read: "Lately he had been using a wrist flexor tendon as the motor unit for the transplant, instead of the extensor carpi ulnaris, and he felt that the flexor tendon was the better.". Professor Brand writes: "I have not been using a wrist flexor tendon as the motor unit. I used one many years ago, and found it is very definitely inferior. I have never used the extensor carpi ulnaris. I assume that the sentence should have read: ‘Lately he has been using the extensor carpi radialis longus as the motor unit for the transplant instead of the extensor carpi radialis brevis, and has taken the graft around the radial side of the forearm and through the carpal tunnel to reach the lumbrical insertions along the lumbrical canals. He found the results were better with this method.’"


Bone & Joint 360
Vol. 9, Issue 3 | Pages 37 - 40
1 Jun 2020


Bone & Joint 360
Vol. 9, Issue 3 | Pages 26 - 29
1 Jun 2020


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims

The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome.

Methods

We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 4 | Pages 780 - 791
1 Nov 1968
Herberts P Kadefors R Kaiser E Petersén I

1. Experience with a refined type of implantable electrode for the myo-electric control of externally powered prostheses is reported. 2. The electrodes are externally energised by electromagnetic induction and therefore do not contain any battery cells. The myo-potentials are transmitted in frequency-modulated form and detected by a receiver placed on the skin. The implantable electrode, measuring 5x11x4 millimetres, is encapsulated in epoxy resin. 3. Six electrodes have been implanted in the forearms of two normal subjects and two below-elbow amputees. The time of implantation ranged from three to fifteen months. Macroscopically, a fibrous capsule developed around the electrodes. Histological examination showed a capsule of granulation tissue of varying thickness with slight inflammatory reaction and foreign-body giant cells. 4. In all cases except one the signals received have been of high quality as ascertained by conventional electromyography and frequency analysis. There has been no significant deterioration in signal quality during the follow-up periods. 5. The major source of failure was fatigue fracture of the gold wires making contact with the body tissues. In one case, however, the electrode was still functioning normally at the time of removal fifteen months after insertion. 6. The patients have not been inconvenienced either by the operative procedures or by the presence of the electrodes in the tissues


Bone & Joint Research
Vol. 9, Issue 6 | Pages 314 - 321
1 Jun 2020
Bliven E Sandriesser S Augat P von Rüden C Hackl S

Aims

Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods.

Methods

A 31B2 Pauwels’ type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 23 - 26
1 Apr 2019