Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 18 - 22
1 Jun 2021
Omari AM Parcells BW Levine HB Seidenstein A Parvizi J Klein GR

Aims

The optimal management of an infrapopliteal deep venous thrombosis (IDVT) following total knee arthroplasty (TKA) remains unknown. The risk of DVT propagation and symptom progression must be balanced against potential haemorrhagic complications associated with administration of anticoagulation therapy. The current study reports on a cohort of patients diagnosed with IDVT following TKA who were treated with aspirin, followed closely for development of symptoms, and scanned with ultrasound to determine resolution of IDVT.

Methods

Among a cohort of 5,078 patients undergoing TKA, 532 patients (695 TKAs, 12.6%) developed an IDVT between 1 January 2014 to 31 December 2019 at a single institution, as diagnosed using Doppler ultrasound at the first postoperative visit. Of the entire cohort of 532 patients with IDVT, 91.4% (486/532) were treated with aspirin (325 mg twice daily) and followed closely. Repeat lower limb ultrasound was performed four weeks later to evaluate the status of IDVT.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 84 - 90
1 Jul 2019
Jennings JM Loyd BJ Miner TM Yang CC Stevens-Lapsley J Dennis DA

Aims

The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps strength and to examine the effects of drain use on secondary outcomes: quadriceps activation, intra-articular effusion, bioelectrical measure of swelling, range of movement (ROM), pain, and wound healing complications.

Patients and Methods

A total of 29 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were enrolled in a prospective, randomized blinded study. Patients were randomized to receive a CSD in one limb while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction (‘sham drain’). Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps activation, intra-articular effusion measured via ultrasound, lower limb swelling measured with bioelectrical impendence and limb girth, knee ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day two, two and six weeks, and three months. Differences between limbs were determined using paired Student’s t-tests or Wilcoxon’s signed-rank tests.


Bone & Joint Research
Vol. 6, Issue 9 | Pages 535 - 541
1 Sep 2017
Zan P Mol MO Yao JJ Fan L Yang D Liu K Li G

Objectives. The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA. Methods. A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis. Results. The incidence of DVT in the early release group (9 of 196, 4.6%) was significantly lower compared with the late release group (24 of 200, 12%; odds ratio (OR) 0.35, 95% confidence interval (CI) 0.16 to 0.78, p = 0.008). The incidence of proximal DVT in the early release group (1 of 196 (0.5%)) was significantly lower than in the late release group (8 of 196, 4%; OR 0.12, 95% CI 0.02 to 0.99, p = 0.020). Although the mean intra-operative blood loss was higher in the early release group, the mean post-operative drainage, total blood loss, transfusion requirements and complications were not significantly different in the two groups. Conclusion. In patients who undergo TKA, releasing the tourniquet early is associated with a decreased incidence of DVT, without increasing the rate of complications. Cite this article: Bone Joint Res 2017;6:535–541


Bone & Joint Research
Vol. 3, Issue 4 | Pages 108 - 116
1 Apr 2014
Cheng K Giebaly D Campbell A Rumley A Lowe G

Objective. Mortality rates reported by the National Joint Registry for England and Wales (NJR) were higher following cemented total knee replacement (TKR) compared with uncemented procedures. The aim of this study is to examine and compare the effects of cemented and uncemented TKR on the activation of selected markers of inflammation, endothelium, and coagulation, and on the activation of selected cytokines involved in the various aspects of the systemic response following surgery. Methods. This was a single centre, prospective, case-control study. Following enrolment, blood samples were taken pre-operatively, and further samples were collected at day one and day seven post-operatively. One patient in the cemented group developed a deep-vein thrombosis confirmed on ultrasonography and was excluded, leaving 19 patients in this cohort (mean age 67.4, (. sd. 10.62)), and one patient in the uncemented group developed a post-operative wound infection and was excluded, leaving 19 patients (mean age 66.5, (. sd. 7.82)). Results. Both groups had a similar response with regards to the levels of C-reactive protein (CRP), interleukin 6 (IL-6) and tumour necrosis factor-alpha (TNFα). CD40 levels rose significantly on the cemented group over day one to day seven compared with that of the uncemented group, which occurred over the first 24 hours. The CD14/42a levels demonstrated a statistically significant increase in the cemented group (p < 0.001 first 24 hours and p = 0.02 between days one and seven). . Conclusions. The uncemented and cemented groups demonstrated significant changes in the various parameters measured at various time points but apart from CD14/42a levels, there was no significant difference in the serum markers of inflammation, coagulation and endothelial dysfunction following cemented TKR. Cite this article: Bone Joint Res 2014;3:108–16


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1351 - 1355
1 Oct 2012
Collins RA Walmsley PJ Amin AK Brenkel IJ Clayton RAE

A total of 445 consecutive primary total knee replacements (TKRs) were followed up prospectively at six and 18 months and three, six and nine years. Patients were divided into two groups: non-obese (body mass index (BMI) < 30 kg/m2) and obese (BMI ≥ 30 kg/m2). The obese group was subdivided into mildly obese (BMI 30 to 35 kg/m2) and highly obese (BMI ≥ 35 kg/m2) in order to determine the effects of increasing obesity on outcome. The clinical data analysed included the Knee Society score, peri-operative complications and implant survival. There was no difference in the overall complication rates or implant survival between the two groups.

Obesity appears to have a small but significant adverse effect on clinical outcome, with highly obese patients showing lower function scores than non-obese patients. However, significant improvements in outcome are sustained in all groups nine years after TKR. Given the substantial, sustainable relief of symptoms after TKR and the low peri-operative complication and revision rates in these two groups, we have found no reason to limit access to TKR in obese patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1321 - 1329
1 Oct 2012
Sarmah SS Patel S Hossain FS Haddad FS

Radiological assessment of total and unicompartmental knee replacement remains an essential part of routine care and follow-up. Appreciation of the various measurements that can be identified radiologically is important. It is likely that routine plain radiographs will continue to be used, although there has been a trend towards using newer technologies such as CT, especially in a failing knee, where it provides more detailed information, albeit with a higher radiation exposure.

The purpose of this paper is to outline the radiological parameters used to evaluate knee replacements, describe how these are measured or classified, and review the current literature to determine their efficacy where possible.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1045 - 1048
1 Aug 2008
Shetty AA Tindall AJ James KD Relwani J Fernando KW

The diagnosis of a meniscal tear may require MRI, which is costly. Ultrasonography has been used to image the meniscus, but there are no reliable data on its accuracy. We performed a prospective study investigating the sensitivity and specificity of ultrasonography in comparison with MRI; the final outcome was determined at arthroscopy. The study included 35 patients with a mean age of 47 years (14 to 73). There was a sensitivity of 86.4% (95% confidence interval (CI) 75 to 97.7), a specificity of 69.2% (95% CI 53.7 to 84.7), a positive predictive value of 82.6% (95% CI 70 to 95.2) and a negative predictive value of 75% (95% CI 60.7 to 81.1) for ultrasonography. This compared favourably with a sensitivity of 86.4% (95% CI 75 to 97.7), a specificity of 100.0%, a positive predictive value of 100.0% and a negative predictive value of 81.3% (95% CI 74.7 to 87.9) for MRI. Given that the sensitivity matched that of MRI we feel that ultrasonography can reasonably be applied to confirm the clinical diagnosis before undertaking arthroscopy. However, the lower specificity suggests that there is still a need to improve the technique to reduce the number of false-positive diagnoses and thus to avoid unnecessary arthroscopy


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 481 - 485
1 Apr 2007
Church JS Scadden JE Gupta RR Cokis C Williams KA Janes GC

Systemic emboli released during total knee replacement have been implicated as a cause of peri-operative morbidity and neurological dysfunction. We undertook a prospective, double-blind, randomised study to compare the cardiac embolic load sustained during computer-assisted and conventional, intramedullary-aligned, total knee replacement, as measured by transoesophageal echocardiography. There were 26 consecutive procedures performed by a single surgeon at a single hospital. The embolic load was scored using the modified Mayo grading system for echogenic emboli.

Fourteen patients undergoing computer-assisted total knee replacement had a mean embolic score of 4.89 (3 to 7) and 12 undergoing conventional total knee replacement had a mean embolic score of 6.15 (4 to 8) on release of the tourniquet. Comparison of the groups using a two-tailed t-test confirmed a highly significant difference (p = 0.004).

This study demonstrates that computer-assisted knee replacement results in the release of significantly fewer systemic emboli than the conventional procedure using intramedullary alignment.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1321 - 1326
1 Oct 2006
Amin AK Clayton RAE Patton JT Gaston M Cook RE Brenkel IJ

The results of 41 consecutive total knee replacements performed on morbidly obese patients with a body mass index > 40 kg/m2, were compared with a matched group of 41 similar procedures carried out in non-obese patients (body mass index < 30 kg/m2). The groups were matched for age, gender, diagnosis, type of prosthesis, laterality and pre-operative Knee Society Score. We prospectively followed up the patients for a mean of 38.5 months (6 to 66). No patients were lost to follow-up. At less than four years after operation, the results were worse in the morbidly obese group compared with the non-obese, as demonstrated by inferior Knee Society Scores (mean knee score 85.7 and 90.5 respectively, p = 0.08; mean function score 75.6 and 83.4, p = 0.01), a higher incidence of radiolucent lines on post-operative radiographs (29% and 7%, respectively, p = 0.02), a higher rate of complications (32% and 0%, respectively, p = 0.001) and inferior survivorship using revision and pain as end-points (72.3% and 97.6%, respectively, p = 0.02).

Patients with a body mass index > 40 kg/m2 should be advised to lose weight prior to total knee replacement and to maintain weight reduction. They should also be counselled regarding the inferior results which may occur if they do not lose weight before surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 335 - 340
1 Mar 2006
Amin AK Patton JT Cook RE Brenkel IJ

A total of 370 consecutive primary total knee replacements performed for osteoarthritis were followed up prospectively at 6, 18, 36 and 60 months. The Knee Society score and complications (perioperative mortality, superficial and deep wound infection, deep-vein thrombosis and revision rate) were recorded. By dividing the study sample into subgroups based on the body mass index overall, the body mass index in female patients and the absolute body-weight. The outcome in obese and non-obese patients was compared. A repeated measures analysis of variance showed no difference in the Knee Society score between the subgroups. There was no statistically-significant difference in the complication rates for the subgroups studied. Obesity did not influence the clinical outcome five years after total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 198 - 202
1 Feb 2006
Kalairajah Y Cossey AJ Verrall GM Ludbrook G Spriggins AJ

We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (before the onset of the procedure) and ward staff. The operations were performed by a single surgeon at one hospital using a uniform surgical approach, instrumentation, technique and release sequence. The only variable in the two groups of patients was the use of single tracker pins of the imageless navigation system in the tibia and femur of the navigated group and intramedullary femoral and tibial alignment jigs in the non-navigated group. Acetabular Doppler signals were obtained in 14 patients in the computer-assisted group and nine (90%) in the conventional group, in whom high-intensity signals were detected in seven computer-assisted patients (50%) and in all of the non-navigated patients. In the computer-assisted group no patient had more than two detectable emboli, with a mean of 0.64 (SD 0.74). In the non-navigated group the number of emboli ranged from one to 43 and six patients had more than two detectable emboli, with a mean of 10.7 (. sd. 13.5). The difference between the two groups was highly significant using the Wilcoxon non-parametric test (p = 0.0003). Our findings show that computer-assisted total knee arthroplasty, when compared with conventional jig-based surgery, significantly reduces systemic emboli as detected by transcranial Doppler ultrasonography


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1137 - 1141
1 Nov 2004
Lachiewicz PF Kelley SS Haden LR

The optimal characteristics of pneumatic compression for mechanical prophylaxis of thromboembolism after total knee arthroplasty (TKA) are not known. Our study compared two methods of calf compression, with the hypothesis that the device which provided a larger increase in peak venous velocity would produce a lower rate of thromboembolism. We performed a prospective, randomised study on 423 patients (472 knees). Duplex ultrasonography was carried out by experienced technicians who were blinded to the device used. Overall, 206 patients (232 knees) used a rapid inflation, asymmetrical compression (RIAC) device and 217 (240 knees) a sequential circumferential compression device (SCD). The rate of venous thromboembolism was 6.9% with the RIAC device compared with 15% for the SCD device (p = 0.007). The incidence of thrombi with unilateral primary TKA was 8.4% for the RIAC compared with 16.8% for the SCD device (p = 0.03). In 47 patients with a bilateral TKA, the incidence of thrombi was 4% for the RIAC compared with 22.7% for the SCD device (p = 0.05 per knee). There was a low rate of mortality and pulmonary embolism when using mechanical prophylaxis for thromboembolism after TKA. Our findings show that the use of rapid inflation, asymmetrical calf compression gave a significantly lower rate of thromboembolism


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 218 - 222
1 Mar 2003
Shetty AA Tindall AJ Qureshi F Divekar M Fernando KWK

Total knee replacement and high tibial osteotomy are common orthopaedic operations with low complication rates. Such surgery is in close proximity to the popliteal artery (PA), the behaviour of which during flexion of the knee is poorly understood. We used Duplex ultrasonography to determine the distance of the PA from the posterior tibial surface at 0° and 90° of flexion in 100 knees. When the knee was flexed the PA was closer to the posterior tibial surface at 1 to 1.5 cm below the joint line in 24% and at 1.5 to 2 cm below the joint line in 15%. There was a high branching anterior tibal artery in 6% of knees. We provide an anatomical account to help to explain our findings by using cadaver dissections, arteriography and static MRI studies