Introduction:

Mayo 2A Olecranon fractures are traditionally managed with a tension band wire device (TBW) but locking plates may also be used to treat these injuries.

Objectives:

To compare clinical outcomes and treatment cost between TBW and locking plate fixation in Mayo 2A fractures.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 7 - 7
1 Aug 2013
Shaw C Badhesha J Ayana G Abu-Rajab R
Full Access

We present a novel use for an adult proximal humeral locking plate. In our case an 18-year-old female with cerebral palsy sustained a peri-prosthetic fracture of a blade plate previously inserted for a femoral osteotomy. Treatment was revision using a long proximal humeral locking plate. She had a successful outcome.

We present the history and operative management.

The female had a history of quadriplegic cerebral palsy, asthma, diabetes mellitus and congenital heart disease. She had a gastrostomy tube for enteral feeding. She was on nutritional supplements, baclofen, Omeprazole and movicol. She is looked after by her parents and requires a wheelchair for mobility. She is unable to communicate. Surgical History: Right adductor tenotomy, aged 11. Femoral Derotation Osteotomy & Dega Acetabular Osteotomy, aged 13. Right distal hamstring and knee capsule release, aged 14. Admitted to A&E (aged 18); unwitnessed fall. Painful, swollen, deformed thigh with crepitus. Xrays demonstrated peri- prosthetic fracture below blade plate.

No specific equipment available to revise. Decision made to use PHILOS (Synthes, UK). GA, antibiotics, supine on table. Lateral approach. Plate removed after excising overgrown bone. Reduced and held. 10hole PHILOS applied. Near anatomical reduction. Secure fixation with locking screws proximally away from blade plate defect. Blood loss 800ml. 5 days in hospital. Sequential fracture clinic review. Wound healed well. Fracture healed on Xray at 11 months and discharged.

To our knowledge this is the first reported use of a PHILOS plate for this specific fracture. The complexity of this case and underlying neurological disorder deemed long blade plate revision unsuitable. Fracture rates after femoral derotation osteotomies rare. 5/157 and 1/58 in the two largest studies to date. Conservative measures were the main recommendation. We have demonstrated a straightforward method for revision fixation with an excellent outcome. It would be recommended as an alternative to other surgeons in this position.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 40 - 40
1 Aug 2013
Spence S Shaw C Badhesha J Clark A Ayana G
Full Access

Olecranon fractures account for 20% of elbow fractures. Displaced fractures can be treated by several methods – Tension Band Wiring (TBW), Open Reduction and Internal Fixation with a plate (ORIF) or conservative measures. Studies from UK specialist centres have demonstrated infection rates of up to 15% and metal ware removal rates of up to 80%. In addition studies have shown that conservative treatment provides a good function and pain relief in the elderly and infirm.

We aimed to look at all displaced olecranon fractures within our unit over a 4 year period and analyse their case notes for patient features, age stratification, treatment methods, complications and outcomes. We also aimed to compare our results to outcomes in studies published by specialist centres.

All olecranon fractures admitted to our unit in calendar years 2007–2010 were identified from our trauma database. Case sheets were analysed for patient's age, co-morbidities, treatment, complications and outcome. X-rays were analysed to classify the fractures and assess outcome of treatment.

71 patients were identified, Male: Female = 33:38. Age range was 7–93, mean was 62.8 years. Treatment used – TBW 42 (59.1%), ORIF 9 (12.7%), and Conservative 20 (28.2%). In the surgical group of 51 patients there were 4 infections (7.8%). There were no incidences of nerve palsy. Metalware was removed in 15 patients (29.4%) – for TBW this was 11/42 (26.25%) and ORIF 4/9 (44.4%) – however the difference was not significant (p=0.06). The conservative group had no complications.

In our study group we have demonstrated a lower infection rate and a far lower rate of metal ware removal than published studies. We have a high rate of patients treated conservatively who do well. Further work is being performed into the functional outcome of the whole group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 8 - 8
1 Aug 2013
Shaw C Badhesha J Ayana G Abu-Rajab R
Full Access

The Exeter Stem (Howmedica, UK) has been in use for over 35 years. Over the years it has undergone several modifications with the most recent being a highly polished, tapered stem in 1986. The manufacturers quote a rate of 0.0006%. In the current literature there are 16 (or less) instances of fractures of the Orthinox stem.

We present a case of fracture of an Orthinox Exeter Stem 9 years after insertion.

Our patient, BB, presented, aged 62, with symptoms & signs consistent with OA right hip. THR was performed through a lateral approach utilising a trochanteric osteotomy. A size 0 37.5 stem was inserted. Radiographs were very satisfactory. She suffered a post operative DVT/PTE from which she recovered uneventfully. She was independently mobile at 6 month review and was discharged at the 2 year stage pain free.

Aged 71, BB presented to outpatient clinic with a several month history of generalised groin pain. She had a Trendelenberg gait. Considerable pain was experienced on axial compression of the limb. Radiographs revealed a midstem fracture with cement loosening proximally. No trauma was reported. She underwent revision surgery through a posterior approach. Acetabular component was rigidly fixed. This was revised to a pressfit Trident (Zimmer, UK) cup with screws & polyethylene liner. An extended trochanteric osteotomy was used to remove the broken stem. An uncemented Restoration (Stryker, UK) stem was inserted with a 28mm head. Post-operative recovery was unremarkable and at 6 months osteotomy has healed. The stem was sent to Stryker UK Laboratories for analysis. They reported the stem broke in fatigue with the origin on the antero-lateral surface. No material or manufacturing defects seen. Dimensionally correct. Fracture may be due to abnormal bending stresses secondary to proximal loosening and firm distal fixation.

Our case demonstrates a set of circumstances that led to inevitable fatigue and stem fracture. The method of failure should reinforce the radiograph appearances that may cause concern or be acted upon.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 6 - 6
1 Aug 2013
Shaw C Badhesha J Clark A Spence S Ayana G
Full Access

Olecranon fractures account for 20% of elbow fractures. Displaced fractures can be treated by several methods – Tension Band Wiring (TBW), Open Reduction and Internal Fixation with a plate (ORIF) or conservative measures. Studies from UK specialist centres have demonstrated infection rates of up to 15% and metalware removal rates of up to 80%. In addition studies have shown that conservative treatment provides good function and pain relief in the elderly and infirm.

To look at all displaced olecranon fractures within our unit (the busiest district general hospital in Scotland) over a 4 year period and analyse for patient features, age stratification, identify treatment methods, complications and outcomes. To compare this to outcomes in studies published by specialist centres.

All olecranon fractures admitted to our unit in calendar years 2007–2010 were identified from our trauma database. Case sheets were analysed for patient's age, co-morbidities, treatment, complications & outcome. Xrays were analysed to classify the fractures and assess outcome of treatment.

71 patients were identified, Male: Female = 33:38. Age range was 7–93. Mean 62.8. Treatment used – TBW 42 (59.1%), ORIF 9 (12.7%), Conservative 20 (28.2%). In the surgical group of 51 patients there were 4 infections (7.8%). There were no incidences of nerve palsy. Metalware was removed in 15 patients (29.4%) – for TBW this was 11/42 (26.25) and ORIF 4/9 (44.4%) – however the difference was not significant (p=0.06). The conservative group had no complications.

In our study group we have demonstrated a lower infection rate and a far lower rate of metalware removal than published studies.?We have a high rate of patients treated conservatively who do well. Further work is being performed into the functional outcome of the whole group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 38 - 38
1 Aug 2013
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult.

We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established, and a case note review was carried out.

There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 15 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. There were no peri-prosthetic fractures in the cemented group, p = 0.004 using Fisher's exact test. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of the patients had a completed falls assessment and 21% sustained their fracture during an admission to hospital) and confusion (50% had a degree of dementia that caused significant confusion).

Cemented implants should be considered in all patients, especially those who are cognitively impaired or have failed falls assessments; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 43 - 43
1 Aug 2013
Badhesha J Spence S Ayana G
Full Access

Low back pain admission to orthopaedics, aged >55, routinely received a myeloma screen (protein electrophoresis and urinary Bence Jones proteins). Myeloma association guidelines outline the symptoms that should trigger investigation. Acute admissions for back pain alone do not form part of this.

We aimed to establish the number of emergency back pain admissions, >55, in our unit over two years. We wished to identify all patients who had protein electrophoresis and/or urinary Bence Jones proteins taken, the number of positive results and diagnoses of myeloma.

From our database all patients >55 admitted with back pain in 2009 and 2010 were identified. Using the electronic laboratory reporting system we recorded FBC/ESR/Electrophoresis/Urinary Bence-Jones Proteins.

There were 7682 admissions from January 2009–December 2010. 87 were for back pain (1.4%). 55 patients were aged >55 years. Within this group – 22 had protein electrophoresis and 23 had Bence-Jones Proteins. All were negative. 36 patients had an ESR taken, 9 were elevated. None were subsequently found to have haematological malignancy. 53 patients had an FBC taken (5 were anaemic, 8 had leucocytosis and 3 had thrombocytopenia). 20 patients had a vertebral fracture (36.4%). There were no documented cases of myeloma.

The Information & Statistics Division of NHS Scotland published figures that demonstrate in 2006–2010, in patients > 55, there were 716 new cases of myeloma in the West of Scotland. Extrapolating this to our unit, on average, we would expect 24 new cases / year in this age group from all presentations. Performing myeloma screens on all back pains does not fulfil recognised screening criteria. We propose myeloma screens are not performed routinely in patients >55 admitted with back pain. It would be reasonable to do so where there is evidence of bone marrow failure, or plasmocytoma on Xray, associated with non-mechanical back pain.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_4 | Pages 35 - 35
1 Jan 2013
Akhtar M Ayana G Smith S
Full Access

Background

Back pain is a common orthopaedic problem which results in hospital admissions in severe cases. The aim of our study was to identify the reasons for back pain admissions and role of further investigations in the treatment of severe back pain.

Methods

We collected data prospectively for all admissions between January and March 2011. Demographic details were recorded along with the reasons for admissions, time of admission, further investigations and treatment offered.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_4 | Pages 13 - 13
1 Jan 2013
Akhtar M Ayana G Smith S
Full Access

Background

Nerve Root compression can lead to severe back pain. Different risk factors like high BMI, smoking, alcohol and psychological history have been identified. The aim of our study was to identify if the incidence of these risk factors was higher in patients with nerve root compression.

Patients and methods

We collected data prospectively for 26 consecutive patients admitted between January and March 2011 with severe back pain and had an MRI scan. Demographic details were recorded along with occupation, BMI, smoking status, alcohol intake and psychological history. 12 patients had nerve root compression (Group A) on MRI scan and 14 had normal MRI scan (Group B).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 41 - 41
1 Jun 2012
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult.

We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established and a case note review carried out.

There were 397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 14 patients (4% of uncemented arthoplasties) had peri-prosthetic fractures. The case notes of these patients were analysed. There was a common link of significant cardiovascular risk, lack of falls assessment, and confusion.

Cemented implants should be considered in those who have failed falls assessment, or are confused; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaethetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit.