Abstract
Olecranon fractures account for 20% of elbow fractures. Displaced fractures can be treated by several methods – Tension Band Wiring (TBW), Open Reduction and Internal Fixation with a plate (ORIF) or conservative measures. Studies from UK specialist centres have demonstrated infection rates of up to 15% and metal ware removal rates of up to 80%. In addition studies have shown that conservative treatment provides a good function and pain relief in the elderly and infirm.
We aimed to look at all displaced olecranon fractures within our unit over a 4 year period and analyse their case notes for patient features, age stratification, treatment methods, complications and outcomes. We also aimed to compare our results to outcomes in studies published by specialist centres.
All olecranon fractures admitted to our unit in calendar years 2007–2010 were identified from our trauma database. Case sheets were analysed for patient's age, co-morbidities, treatment, complications and outcome. X-rays were analysed to classify the fractures and assess outcome of treatment.
71 patients were identified, Male: Female = 33:38. Age range was 7–93, mean was 62.8 years. Treatment used – TBW 42 (59.1%), ORIF 9 (12.7%), and Conservative 20 (28.2%). In the surgical group of 51 patients there were 4 infections (7.8%). There were no incidences of nerve palsy. Metalware was removed in 15 patients (29.4%) – for TBW this was 11/42 (26.25%) and ORIF 4/9 (44.4%) – however the difference was not significant (p=0.06). The conservative group had no complications.
In our study group we have demonstrated a lower infection rate and a far lower rate of metal ware removal than published studies. We have a high rate of patients treated conservatively who do well. Further work is being performed into the functional outcome of the whole group.