header advert
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 129 - 129
11 Apr 2023
Vermeir R Wittouck L Peiffer M Huysse W Martinelli N Stufkens S Audenaert E Burssens A
Full Access

The incisura fibularis (IF) provides intrinsic stability to the ankle joint complex by interlocking the distal tibia and fibula. Despite a high frequency of ligamentous ankle injuries, scant attention has been given to the morphology of the IF morphology incisura fibularis in the onset and development of these lesions. Therefore, we systematically reviewed the relation between ligamentous ankle disorders and the morphometrics of the IF. A systematic literature search was conducted on following databases: PubMed, Embase and Web of Science. Search terms consisted of ‘ankle trauma’, ‘ankle injury’, ‘ankle sprain’, ‘ankle fracture’, ‘tibiofibular’, ‘fibular notch’, ‘fibular incisura’, ‘incisura fibularis’, ‘morphometric analysis’, ‘ankle syndesmosis’, ‘syndesmotic stability’. The evaluation instrument developed by Hawker et al. was used to assess the quality of the selected studies. This protocol was performed according to the PRISMA guidelines and is registered on PROSPERO (CRD42021282862). Nineteen studies were included and consisted of prospective cohort (n=1), retrospective comparative (n=10), and observational (n=8) study design. Comparative studies have found certain morphological characteristics in patients with ankle instability. Several studies (n=5) have correlated a shallow IF depth with a higher incidence of ankle injury. A significant difference has also been found concerning the incisura height and angle (n=3): a shorter incisura and more obtuse angle have been noted in patients with ankle sprains. The mean Hawker score was 28 out of 36 (range=24-31). A shallower IF is associated with ligamentous ankle lesions and might be due to a lower osseous resistance against tibiofibular displacement. However, these results should be interpreted in light of moderate methodological quality and should always be correlated with clinical findings. Further prospective studies are needed to further assess the relation between the incisura morphometrics and ligamentous disorders of the ankle joint. Keywords: ankle instability, ankle injury, incisura fibularis, fibular notch, tibiofibular morphometrics, ankle syndesmosis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 33 - 33
17 Apr 2023
Hafeji S Brockett C Edwards J
Full Access

Ligament integrity is directly associated with ankle stability. Nearly 40% of ankle sprains result in chronic ankle instability, affecting biomechanics and potentially causing osteoarthritis. Ligament replacement could restore stability and avoid this degenerative pathway, but a greater understanding of ankle ligament behaviour is required. Additionally, autograft or allograft use is limited by donor-site morbidity and inflammatory responses respectively. Decellularised porcine grafts could address this, by removing cellular material to prevent acute immune responses, while preserving mechanical properties. This project will characterise commonly injured ankle ligaments and damage mechanisms, identify ligament reconstruction requirements, and investigate the potential of decellularised porcine grafts as a replacement material. Several porcine tendons were evaluated to identify suitable candidates for decellularisation. The viscoelastic properties of native tissues were assessed using dynamic mechanical analysis (DMA), followed by ramp to ‘sub-rupture’ at 1% strain/s, and further DMA. Multiple samples (n=5) were taken along the graft to assess variation along the tendon. When identifying suitable porcine tendons, a lack of literature on human ankle ligaments was identified. Inconsistencies in measurement methods and properties reported makes comparison between studies difficult. Preliminary testing on porcine tendons suggested there is little variation in viscoelastic properties along the length of tendon. Testing also suggested strain rates of 1%/s sub-rupture was not large enough to affect viscoelastic properties (no changes in storage or loss moduli or tanẟ). Further testing is underway to improve upon low initial sample numbers and confirm these results, with varying strain rates to identify suitable sub-rupture sprain conditions. This work highlights need for new data on human ankle ligaments to address knowledge gaps and identify suitable replacement materials. Future work will generate this data and decellularise porcine tendons of similar dimensions. Collagen damage will be investigated using histology and lightsheet microscopy, and viscoelastic changes through DMA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 128 - 128
1 Nov 2018
Zadran S Christensen K Petersen T Rasmussen S
Full Access

Acute lateral ankle sprain accounts for 85% of sprains. The lateral sprain is associated with other ligament injuries e.g. medial and syndesmosis sprain. Long-term, approximately 20% of acute lateral sprains develop into chronic lateral ankle instability (CLAI) which includes persistent pain, and recurring ankle sprains. This study evaluated the grade of an ankle ligament injury by ultrasonography (US) and compared the findings to the outcome of patient-reported questionnaires. 48 subjects (18–40 years) diagnosed with an ankle sprain attended a clinical and US examination of ankle ligaments within two weeks after the sprain. Evaluation was done by US of acute lateral ligament injuries (ATFL, CFL), syndesmosis injury (AiTFL), and medial injury (dPT, TCt) only in participants with the positive clinical signs of medial injury. Participants were then mailed a questionnaire (PROMQ) every third month for a year. 29 women and 19 men participated with a mean age at 26.50 years. One-year follow-ups need to be analyzed further for final results. Temporary results include data based on the initial 26 patients: Two clinical signs statistically correlated. Multiple logistic regression analysis confirmed the results. Positive palpated tenderness AiTFL predicted with partial ruptured ATFL and reported pain during active plantar flexion of ankle predicted with normal CFL confirmed by the US. Patients with partial rupture of ATFL presented with tenderness at AiTFL point. Patients presenting with intact CFL reported pain during active plantar flexion. Compared to the US findings, the overall examinations were inconclusive in predicting ATFL, CFL, AiTFL, and medial ligament injuries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 61 - 61
11 Apr 2023
Wendlandt R Herchenröder M Hinz N Freitag M Schulz A
Full Access

Vacuum orthoses are being applied in the care of patients with foot and lower leg conditions, as ankle fractures or sprains. The lower leg is protected and immobilized, which increases mobility. Due to the design, the orthoses lead to a difference in leg length, i.e. the side with the orthosis becomes longer, which changes the gait kinematics. To prevent or mitigate the unfavourable effects of altered gait kinematics, leg length-evening devices (shoe lifts) are offered that are worn under the shoe on the healthy side. Our aim was to evaluate the effect of such a device on the normality of gait kinematics. Gait analysis was conducted with 63 adult, healthy volunteers having signed an informed consent form that were asked to walk on a treadmill at a speed of 4.5km/h in three different conditions:. barefoot - as reference for establishing the normality score baseline. with a vacuum orthosis (VACOPed, OPED GmbH, Germany) and a sport shoe. with a vacuum orthosis and a shoe lift (EVENup, OPED GmbH, Germany). Data was sampled using the gait analysis system MCU 200 (LaiTronic GmbH, Austria). The positions of the joint markers were exported from the software and evaluated for the joint angles during the gait cycle using custom software (implemented in DIAdem 2017, National Instruments). A normality score using a modification of the Gait Profile Score (GPS) was calculated in every 1%-interval of the gait cycle and evaluated with a Wilcoxon signed rank test. The GPS value was reduced by 0.33° (0.66°) (median and IQR) while wearing the shoe lift. The effect was statistically significant, and very large (W = 1535.00, p < .001; r (rank biserial) = 0.52, 95% CI [0.29, 0.70]). The significant reduction of the GPS value indicates a more normal gait kinematics while using the leg length-evening device on the contralateral shoe. This rather simple and inexpensive device thus might improve patient comfort and balance while using the vacuum orthoses


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 17 - 17
1 Nov 2018
Cornelis B Van Waeyenberge M Burssens A De Mits S Bodere I Buedts K Audenaert E
Full Access

High ankle sprains (HAS) cause subtle lesions in the syndesmotic ligaments of the distal tibiofibular joint (DTFJ). Current intrinsic anatomical parameters of the DTFJ are determined based on 2D imaging and uncertainty remains whether they differ in a HAS patients. The aim of this study is therefore two-fold: radiographic parameters will be determined in 3D and compared in a healthy vs sprained group. Ten patients with a mean age of 42,56 (SD = 15,38) that sustained a HAS and twenty-five control subjects with a mean age of 47,44 (SD = 6,55) were retrospectively included. The slices obtained from CT analysis were segmented to have a 3D reconstruction. The following DTFJ anatomical parameters were computed using CAD software: incisura width, incisura depth, incisura length, incisura angle, and incisura-tibia ratio. The mean incisura depth in the sprained group was 3,93mm (SD = 0,80) compared to 4,76 mm (SD = 1,09) in the control group, which showed a significant difference (P < 0.05). The mean incisura length in the group of patients with HAS was 30,81 mm (SD = 3,17) compared to 36,10mm (SD = 5,27) in the control group which showed a significant difference (P < 0.05). The other DTFJ anatomical parameters showed no significant difference. This study shows a significant difference in both incisura depth and incisura length between HAS patients and control subjects. These parameters could be used to identify potential anatomical intrinsic risk factors in sustaining a HAS


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 15 - 15
1 Jan 2019
Rochelle D Herbert A Ktistakis I Redmond AC Chapman G Brockett CL
Full Access

Whilst lateral ankle sprain is often considered a benign injury it represents between 3–5% of all A&E visits in the UK. The mechanical characteristics of ankle ligaments under sprain-like conditions are scarcely reported. The lateral collateral ankle ligaments were dissected from n=6 human cadaveric specimens to produce individual bone-ligament-bone specimens. An Instron Electropuls E10000 was used to uni-axially load the ankle ligaments in tension. The ligaments were first preconditioned between 2 N and a load value corresponding to 3.5% strain for 15 cycles and then strained to failure at a rate of 100%/s. The mean ultimate failure loads and their standard deviations for the anterior talofibular (ATFL), calcaneofibular (CFL) and posterior talofibular (PTFL) ligaments are 351.4±105.6 N, 367.8±76.1 N and 263.6±156.6 N, respectively. Whilst the standard deviation values are high they align with those previously reported for ankle ligament characterisation. The large standard deviations are partly due to the inherent variability of human cadaveric tissue but could also be due to varying previous activity levels of participants or a prior unreported ankle sprain. Although the sample size is relatively small the results were stratified to identify any potential correlations of age, BMI and weight with ultimate load. A strong Pearson correlation (r=0.919) was found between BMI and ultimate load of the CFL but a larger sample size is required to confirm a link. The ligament failure modes were observed and categorised as avulsion or intra-ligamentous failure. The ATFL avulsed from the fibula in five instances and intra-ligamentous failure occurred once. The CFL avulsed from the fibula twice and failed four times through intra-ligamentous failure. Finally, the PTFL avulsed from the fibula once, avulsed from the talus once and failed through intra-ligamentous failure in four instances. The results identify the forces required to severely sprain the lateral collateral ankle ligaments and their failure modes


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 320 - 320
1 Jul 2014
Aframian A Jindasa O Khor K Vinayakam P Spencer S Jeer P
Full Access

Summary. Nearly one-third of patients in this series with an ACL rupture requiring reconstruction had evidence of MPFL injury. This should be considered when patients are seen, and when MRI scans are reviewed/reported. Introduction. The Medial Patello-Femoral Ligament (MPFL) is the largest component of the medial parapatellar ligamentous complex. The senior surgeon felt that there was an anecdotally high rate of MPFL injury amongst his patients undergoing Anterior Cruciate Ligament (ACL) repair, but no discussion of this in the present literature. Method. A literature search was performed; although there were both scanty radiographic and anatomical studies of the MPFL, we found no literature looking at ACL and MPFL concurrent injury rates. The Magnetic Resonance Imaging (MRI) scans of fifty consecutive ACL reconstruction patients were retrospectively reviewed. Two independent radiologists were asked to review the scans looking specifically for evidence of MPFL rupture or Injury. The degree of injury was rated as rupture or by degree of sprain as applicable. One patient was excluded due to motion artefact limiting certainty. Results. Of the remaining forty-nine patients, 35 (71%) were intact, but fourteen (29%) showed evidence of injury. Five (10%) had a low-grade sprain, six (12%) had high-grade sprain, and three (6%) had complete rupture. The radiologists also noted that there was some variation in scanning protocols, and those with fat suppressed scans had better diagnostic value; this offered an opportunity to change the scanning practice. Conclusion. Nearly one-third of patients in this series with an ACL rupture requiring reconstruction had evidence of MPFL injury. This should be considered when patients are seen, and when MRI scans are reviewed/reported. Further, we would suggest that fat suppression sequences are included as standard to improve imaging quality


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 61 - 61
1 Dec 2020
Ramos A Mesnard M Sampaio P
Full Access

Introduction. The ankle cartilage has an important function in walking movements, mainly in sports; for active young people, between 20 and 30 years old, the incidence of osteochondral lesions is more frequent. They are also more frequent in men, affecting around 21,000 patients per year in USA with 6.5% of ankle injuries generating osteochondral lesions. The lesion is a result of ankle sprain and is most frequently found in the medial location, in 53% of cases. The main objective of this work was to develop an experimental and finite element models to study the effect of the ankle osteochondral lesion on the cartilage behavior. Materials and Methods. The right ankle joint was reconstructed from an axial CT scan presenting an osteochondral lesion in the medial position with 8mm diameter in size. An experimental model was developed, to analyze the strains and influence of lesion size and location similar to the patient. The experimental model includes two cartilages constructed by Polyjet™ 3D printing from rubber material (young modulus similar to cartilage) and bone structures from a rigid polymer. The cartilage was instrumented with two rosettes in the medial and lateral regions, near the osteochondral region. The fluid considered was water at room temperature and the experimental test was run at 1mm/s. The Finite element model (FE) includes all the components considered in the experimental apparatus and was assigned the material properties of bone as isotropic and linear elastic materials; and the cartilage the same properties of rubber material. The fluid was simulated as hyper-elastic one with a Mooney-Rivlin behavior, with constants c1=0.07506 and c2=0.00834MPa. The load applied was 680N in three positions, 15º extension, neutral and 10º flexion. Results. The experimental strain measured in the cartilage in the rosettes presents similar behavior in all experiments and repetitions. The maximum value observed near the osteochondral lesion was 3014(±5.6)µε in comparison with the intact condition it was 468 (±1.95)µε. The osteochondral lesion increases the strains around 6.5 times and the synovial liquid reduces the intensity of strain distribution. The numerical model presents a good correlation with the experiments (R2 0.944), but the FE model underestimates the values. Discussion and conclusion. As a first conclusion, the size of the osteochondral lesion is important for the strains developed in cartilage. The size of lesion greater than 10mm is critical for the strains concentration. The synovial fluid present an important aspect in the strains measured, it reduces the strains in the external surface of cartilage and induces an increase in the lower part. This phenomenon should be addressed in more studies to evaluate this effect


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 27 - 27
1 Jul 2014
Theelen L Wentink N Dhooge Y Senden R Hemert van W Grimm B
Full Access

Summary. Movement analysis (IMA) and activity monitoring (AM) using a body-fixed inertia-sensor can discriminate patients with ankle injuries from controls and between patients of different pathology or post-injury time. Weak correlations with PROMs show its added value in objectifying outcome assessment. Introduction. Ankle injuries often result in residual complaints calling for objective methods to score outcome alongside subjective patient-reported outcome measures (PROMs). Inertial motion analysis (IMA) and activity monitoring (AM) using a body-fixed sensor have shown clinical validity in patients suffering knee, hip and spine complaints. This study investigates the feasibility of IMA and AM 1) to differentiate patients suffering ankle injuries from healthy controls, 2) to compare different ankle injuries, 3) to monitor ankle patients during recovery. Methods. 32 patients suffering ankle problems (ankle sprain, n=17, 42 ±26yrs; operatively managed ankle fracture, n=15, 44 ±17yrs) during short-term recovery (6weeks to 3months post-trauma) were compared to 22 matched healthy controls (41 ±13yrs). Function was measured using IMA: Gait, Sit-Stand (STS) and 10s one-leg Balance test (OLB) were performed while wearing a 3D inertia-sensor at the lower back. Physical activity was measured during 4 successive days using a 3D accelerometer (AM), attached at the upper leg. Validated algorithms were used to derive motion parameters (e.g. speed for gait, bending angle for STS, sway area for OLB, # steps for AM). Moreover three ankle specific questionnaires were completed: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ), Foot and Ankle Ability Measure (FAAM), AOFAS ankle-hindfoot score. Data was analysed using paired t-tests, one-way ANOVA and Pearson's r. Results. Both patient groups performed worse in function (IMA), activity (AM) and scales (PROM). Even at 3 months mean walking speed (−26%) and cadence (−9%) were slower while pelvic obliquity during ST (+18%) and sway during OLB (+230%) was higher than in controls (p<0.05). Activity was less regarding step/day (−31%) and sit-stand transfers (−11%, p<0.05). Also PROMs were significantly worse in patients (range 17–37%). Comparing in-between patients, significant differences were found in PROMs and function (IMA) with fracture patients walking slower (−30%) or showing more sway during one-legged balance (+250%). Mean activity scores (steps, bouts, cadence) were also less for fractures (p>0.05). During recovery, PROMs improved significantly, while function (IMA) and activity (AM) only showed small or selective improvements (e.g. 8° reduction in bending angle during ST, 20% increase in cadence). Only weak to moderate correlations were found between PROM, IMA (r-range: 0.32–0.79) and AM parameters (r-range: 0.31–0.71). Discussion & Conclusion. Function, physical activity and PROMs were impaired in patients with ankle injuries compared to healthy subjects, with the fracture group performing worse on IMA and PROMs than the sprain group. In this first study ever to measure activity in ankle patients, it was shown that e.g. fracture patients walk ca. half as many steps and bouts as age-matched controls even though at 6weeks they were unable to walk 20m without walking aids (floor effect of IMA function test). The lack of improvements in IMA and AM during recovery while PROMs improved significantly, together with the few and only weak-to-moderate correlations between PROMs, IMA and AM shows that subjective and objective recovery differ and highlight the added value of IMA and AM for objectifying routine clinical outcome assessment


Bone & Joint 360
Vol. 10, Issue 1 | Pages 45 - 46
1 Feb 2021
Das A


Bone & Joint Research
Vol. 5, Issue 12 | Pages 610 - 618
1 Dec 2016
Abubakar AA Noordin MM Azmi TI Kaka U Loqman MY

In vivo animal experimentation has been one of the cornerstones of biological and biomedical research, particularly in the field of clinical medicine and pharmaceuticals. The conventional in vivo model system is invariably associated with high production costs and strict ethical considerations. These limitations led to the evolution of an ex vivo model system which partially or completely surmounted some of the constraints faced in an in vivo model system. The ex vivo rodent bone culture system has been used to elucidate the understanding of skeletal physiology and pathophysiology for more than 90 years. This review attempts to provide a brief summary of the historical evolution of the rodent bone culture system with emphasis on the strengths and limitations of the model. It encompasses the frequency of use of rats and mice for ex vivo bone studies, nutritional requirements in ex vivo bone growth and emerging developments and technologies. This compilation of information could assist researchers in the field of regenerative medicine and bone tissue engineering towards a better understanding of skeletal growth and development for application in general clinical medicine.

Cite this article: A. A. Abubakar, M. M. Noordin, T. I. Azmi, U. Kaka, M. Y. Loqman. The use of rats and mice as animal models in ex vivo bone growth and development studies. Bone Joint Res 2016;5:610–618. DOI: 10.1302/2046-3758.512.BJR-2016-0102.R2.


Bone & Joint Research
Vol. 3, Issue 8 | Pages 252 - 261
1 Aug 2014
Tilley JMR Murphy RJ Chaudhury S Czernuszka JT Carr AJ

Objectives

The effects of disease progression and common tendinopathy treatments on the tissue characteristics of human rotator cuff tendons have not previously been evaluated in detail owing to a lack of suitable sampling techniques. This study evaluated the structural characteristics of torn human supraspinatus tendons across the full disease spectrum, and the short-term effects of subacromial corticosteroid injections (SCIs) and subacromial decompression (SAD) surgery on these structural characteristics.

Methods

Samples were collected inter-operatively from supraspinatus tendons containing small, medium, large and massive full thickness tears (n = 33). Using a novel minimally invasive biopsy technique, paired samples were also collected from supraspinatus tendons containing partial thickness tears either before and seven weeks after subacromial SCI (n = 11), or before and seven weeks after SAD surgery (n = 14). Macroscopically normal subscapularis tendons of older patients (n = 5, mean age = 74.6 years) and supraspinatus tendons of younger patients (n = 16, mean age = 23.3) served as controls. Ultra- and micro-structural characteristics were assessed using atomic force microscopy and polarised light microscopy respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1660 - 1665
1 Dec 2007
Krause F Windolf M Schwieger K Weber M

A cavovarus foot deformity was simulated in cadaver specimens by inserting metallic wedges of 15° and 30° dorsally into the first tarsometatarsal joint. Sensors in the ankle joint recorded static tibiotalar pressure distribution at physiological load.

The peak pressure increased significantly from neutral alignment to the 30° cavus deformity, and the centre of force migrated medially. The anterior migration of the centre of force was significant for both the 15° (repeated measures analysis of variance (ANOVA), p = 0.021) and the 30° (repeated measures ANOVA, p = 0.007) cavus deformity. Differences in ligament laxity did not influence the peak pressure.

These findings support the hypothesis that the cavovarus foot deformity causes an increase in anteromedial ankle joint pressure leading to anteromedial arthrosis in the long term, even in the absence of lateral hindfoot instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 164 - 168
1 Jan 2010
Chen MR Huang JI Victoroff BN Cooperman DR

In an osteological collection of 3100 specimens, 70 were found with unilateral clavicular fractures which were matched with 70 randomly selected normal specimens. This formed the basis of a study of the incidence of arthritis of the acromioclavicular joint and the effect of clavicular fracture on the development of arthritis in the ipsilateral acromioclavicular joint. This was graded visually on a severity scale of 0 to 3. The incidence of moderate to severe arthritis of the acromioclavicular joint in normal specimens was 77% (100 specimens). In those with a clavicular fracture, 66 of 70 (94%) had arthritis of the acromioclavicular joint, compared to 63 of 70 (90%) on the non-injured contralateral side (p = 0.35).

Clavicles with shortening of 15 mm or less had no difference in the incidence of arthritis compared to those with shortening greater than 15 mm (p = 0.25). The location of the fracture had no effect on the development of arthritis.