Pressure ulcers are a common occurrence in individuals with spinal cord injuries, and are attributed to prolonged sitting and limited mobility. This therefore creates the need to better understand soft tissue composition, in the attempt to prevent and treat pressure ulcers. In this study, novel approaches to imaging the soft tissue of the buttocks were investigated in the loaded and unloaded
Total hip arthroplasty (THA) using minimally invasive surgeries (MIS) now become popular operative procedures. It is not easy to understand geometric information of pelvis and femur in the restricted operative fields during MIS-THA. Recently, THA in supine
Introduction. The
Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and dynamic fixation on post-injury syndesmosis kinematics. As the syndesmosis is a dynamic structure, conventional CT static images do not provide a complete picture of syndesmosis
Total shoulder arthroplasty (TSA) is an effective treatment for end-stage glenohumeral arthritis. The use of high modulus uncemented stems causes stress shielding and induces bone resorption of up to 63% of patients following TSA. Shorter length stems with smaller overall dimensions have been studied to reduce stress shielding, however the effect of humeral short stem varus-valgus
Proper
Introduction. Most of studies on Total Hip Arthroplasty (THA) are focused on acetabular cup orientation. Even though the literature suggests that femoral anteversion and combined anteversion have a clinical impact on THA stability, there are not many reports on these parameters. Combined anteversion can be considered morphologically as the addition of anatomical acetabular and femoral anteversions (Anatomical Combined Anatomical Anteversion ACA). It is also possible to evaluate the Combined Functional Anteversion (CFA) generated by the relative functional
In the polytrauma patient, intraoperative patient
Purpose. In vivo comparative gap measurements were performed in 3 different patella
INTRODUCTION. Thorough understanding and feedback of the post-operative implant
Background. Supine
The lower limbs of vehicle occupants are vulnerable to severe injuries during under vehicle explosions. Understanding the injury mechanism and causality of injury severity could aid in developing better protection. Therefore, we tested three different knee
Introduction. Hip resurfacing arthoplasty (HRA) is an alternative to total hip arthroplasty (THA), which has increased in the last years, especially in young patients. A suitable
Soft tissue balance is important for good clinical outcome and good stability after TKA. Ligament balancer is one of the devices to measure the soft tissue balance. The objective of this study is to clarify the effect of the difference in the rotational
Introduction. While THA is associated with positive results and long-term improvement in patient quality of life, outcomes are nonetheless associated with adverse events and post-procedural deficits related to discrepancies in leg length (LLD), offset and cup placement. Post-THA errors in these parameters are associated with gait alteration, low back pain and patient dissatisfaction. Such discrepancies often necessitate revision and increasingly lead to medical malpractice litigation. Maintaining accuracy in post-surgical leg length, offset and cup placement during THA is difficult and subject to error. The sensitivity of these factors is highlighted in studies that have shown that a change of as little as 5 degrees of flexion or abduction can induce alterations in leg length of up to several millimeters. Similarly,
Introduction. Computer-assisted orthopaedic surgery (CAOS) provides great value in ensuring accurate, reliable and reproducible total knee arthroplasty (TKA) outcomes [1,2]. Depending on surgeon preferences or patient factors (e.g. BMI, ligament condition, and individual joint anatomy), resection planning (guided adjustment of cutting blocks) is performed with different knee flexion, abduction/adduction (ABD/ADD) and internal/external (I/E) rotation angles, potentially leading to measurement errors in the planned resections due to a modified tracker/localizer spatial relationship. This study assessed the variation in the intraoperative measurement of the planned resection due to leg manipulation during TKA, and identified the leg
Introduction. Robotic-assisted hip arthroplasty helps acetabular preparation and implantation with the assistance of a robotic arm. A computed tomography (CT)-based navigation system is also helpful for acetabular preparation and implantation, however, there is no report to compare these methods. The purpose of this study is to compare the acetabular cup
Purpose. The measurement of radial head translation about the capitellum (in percent): the radio-capitellum ratio (RCR) has proven to have excellent inter- and intra-observer reliabilities when measuring the RCR on a lateral radiological view of elbows at 90° of flexion and in the neutral
Introduction. Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup
There has been a lot of focus on the value of anatomic tunnel placement in ACL reconstruction, and the relative merits of single and double bundle grafts. Multiple cadaveric and animal studies have compared the effects of tunnel placement and graft type on knee biomechanics. 45 patients who underwent ACL reconstruction were included into our study. Femoral tunnel