Elective
Introduction. Knee arthroplasty (KA), encompassing Total Knee Replacement (TKR) and Unicompartmental Knee Replacement (UKR), is one of the most common
Evidence supporting the use of virtual reality (VR) training in
Introduction. Perioperative antibiotic prophylaxis use in modern
INTRODUCTION. Warfarin remains the treatment of choice for the majority of patients with venous thromboembolism, atrial fibrillation and valvular heart disease or valve replacement unless contraindicated. Poor management of patients on warfarin often leads to delay in surgery, life threatening bleeding during or after operation and unnecessary delay in discharge from hospitals in United Kingdom. METHODS. We carried out a prospective study on patients who were on warfarin and underwent elective and emergency
Abstract. Objectives. Evidence supporting the use of immersive virtual reality (iVR) training in
The risk of falls in patients undergoing
Total knee arthroplasty (TKA) is a common
Objectives. Surgeons face a substantial risk of infection because of the occupational exposure to blood-borne pathogens (BBPs) from patients undergoing high-risk
Rapid prototyping (RP), especially useful in surgical specialities involving critical three-dimensional relationships, has recently become cheaper to access both in terms of file processing and commercially available printing resources. One potential problem has been the accuracy of models generated. We performed computed tomography on a cadaveric human patella followed by data conversion using open source software through to selective-laser-sintering of a polyamide model, to allow comparative morphometric measurements (bone v. model) using vernier calipers. Statistical testing was with Student's t-test. No significant differences in the dimensional measurements could be demonstrated. These data provide us with optimism as to the accuracy of the technology, and the feasibility of using RP cheaply to generate appropriate models for operative rehearsal of intricate
A number of advantages of unicondylar arthroplasty (UKA) over total knee arthroplasty in patients presenting osteoarthritis in only a single compartment have been identified in the literature. However, accurate implant positioning and alignment targets, which have been shown to significantly affect outcomes, are routinely missed by conventional techniques. Computer Assisted Orthopaedic Surgery (CAOS) has demonstrated its ability to improve implant accuracy, reducing outliers. Despite this, existing commercial systems have seen extremely limited adoption. Survey indicates the bulk, cost, and complexity of existing systems as inhibitive characteristics. We present a concept system based upon small scale head mounted tracking and augmented reality guidance intended to mitigate these factors. A visible-spectrum stereoscopic system, able to track multiple fiducial markers to 6DoF via photogrammetry and perform semi-active speed constrained resection, was combined with a head mounted display, to provide a video-see-through augmented reality system. The accuracy of this system was investigated by probing 180 points upon a 110×110×50 mm known geometry and performing controlled resection upon a 60×60×15 mm bone phantom guided by an overlaid augmented resection guide that updated in real-time. The system produced an RMS probing accuracy and precision of 0.55±0.04 and 0.10±0.01 mm, respectively. Controlled resection resulted in an absolute resection error of 0.34±0.04 mm with a general trend of over-resection of 0.10±0.07 mm. The system was able to achieve the sub-millimetre accuracy considered necessary to successfully position unicondylar knee implants. Several refinements of the system, such as pose filtering, are expected to increase the functional volume over which this accuracy is obtained. The presented system improves upon several objections to existing commercial CAOS UKA systems, and shows great potential both within surgery itself and its training. Furthermore, it is suggested the system could be readily extended to additional
Background. Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software. Methods. The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students. Results. The median absolute inaccuracy of FluoroSim with 270 measurements was 3.35mm (IQR = [1.15mm, 6.53mm]). The absolute inaccuracy showed a graded increase the further away the tip of the guide-wire was from the centre of calibration; MGAD ≤10mm, median absolute inaccuracy = 1.53mm; MGAD 10mm<x≤20mm, median absolute inaccuracy = 4.97mm; MGAD >20mm, median absolute inaccuracy = 7.23mm. Comparison between all three groups reached significance (p < 0.001). In a simulation scenario with medical students, FluoroSim had a significantly greater median absolute inaccuracy of 4.79mm compared to the testing scenario (p < 0.001). Conclusion. FluoroSim is a safe and inexpensive digital imaging adjunct to workshop bones simulation. To our knowledge this technology has not been explored in the context of DHS simulation, and has the potential to be extended to other
We have compared the rates of infection and resistance in an animal model of an
Previous studies of the Ilizarov procedure have concentrated on musculoskeletal assessments rather than the opinions of patients. In a prospective trial of 25 consecutive patients, we evaluated the effect of Ilizarov reconstruction of post-traumatic deformity on general health status using the SF36 and Nottingham Health Profile (NHP). The patients had very low preoperative scores, which remained low during treatment and correction, but increased postoperatively. The mean overall SF36 score improved from 36 ± 3 to 58 ± 7 (p = 0.031) and the NHP score from 39 ± 11 to 67 ± 10 (p = 0.002). The improvements in scores were not limited to the physical components and were equal or better than the improvements reported for other
Total knee arthroplasty (TKA) is a common
Synthetic bone grafts are used in several major dental and
Intra-articular screw fixation is indicated for internal fixation of large osteochondral fragments secondary to trauma or osteochondritis dissecans. During surgery, orthopaedic drills are used to prepare a hole through which the screw can pass. Previous work has shown that mechanical injury to articular cartilage results in a zone of cell death adjacent to the traumatised articular cartilage (1). Here, we characterise and quantify the margin of in situ chondrocyte death surrounding drill holes and screws (standard cortical and headless compression designs) placed in mature bovine articular cartilage to model the
Summary Statement. Preoperative bone-marrow-derived cell mobilization by G-CSF is a safe
Many
Aim. The aim of this study is to outline the steps and techniques required to create a patient specific 3D printed guide for the accurate placement of the origin of the femoral tunnel for single bundle ACL reconstruction. Introduction. Placements of the femoral tunnels for ACL reconstruction have changed over the years. Most recently there has been a trend towards placing the tunnels in a more anatomic position. There has been subsequent debate as to where this anatomic position should be. The problem with any attempt at consensus over the placement of an anatomic landmark is that each patient has some variation in their positioning and therefore a fixed point for all has compromise for all as it is an average. Our aim was to attempt to make a cost effective and quick custom guide that could allow placement of the center of the patients’ newly created femoral tunnel in the mid position of their contralateral native ACL femoral footprint. Materials & Methods. We took a standard protocol MRI scan of a patient's knee without ACL injury transferred the DICOM files to a personal computer running OsiriX (Pixmeo, Geneva, Switzerland.) and analysed it for a series of specific anatomical landmarks. OsiriX is an image processing software dedicated to DICOM images. We marked the most posterior edge of the articular cartilage on the lateral wall of the notch (1), the most anterior edge of the articular cartilage of the lateral wall of the notch (2), the most inferior edge of the articular cartilage of the lateral wall of the notch (3) and the center of the femoral footprint of the native ACL. Distances were then calculated to determine the position relative to the three articular cartilage points of the center of the ACL footprint. These measurements and points were then utilised to create a 3D computer aided design (CAD) model of a custom guide. This was done using the 3D CAD program 123Design (Autodesk Ltd., Farnbourgh, Hampshire). This 3D model was then exported as an STL file suitable for 3D printing. The STL file was then uploaded to an online 3D printing service and the physical guide was created in transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel. The models created were then measured using vernier calipers to confirm the accuracy of the final guides. Results. The MRI data showed point 1 (AP), point 2 (distal-ACL), point 3 (Ant-ACL) and point 4 (Post-ACL) at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the 3D CAD model, points 1, 2, 3 and 4 were at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the PA220 plastic model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.48, 45.85 and 13.79 respectively. For the 316L stainless steel model, points 1, 2, 3 and 4 were at a distance of 59.79, 14.67, 45.64 and 13.48 respectively. Lastly, for the photopolymer model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.2, 45.4 and 13.69 respectively. The p-value comparing MRI/CAD vs. PA220 was p=0.3753; for the comparison between MRI/CAD vs. 316L, p=0.0683; lastly for the comparison between MRI/CAD Vs. Photopolymer, p=0.3450. The models produced were accurate with no statistical difference in size and positioning of the center of the ACL footprint from the original computer model and to the position of the ACL from the MRI scans. The costs for the models 3D printed were £3.50 for the PA220 plastic, £15 for the transparent photopolymer and £25 for the 316L stainless steel. The time taken from MRI to delivery for the physical models was 7 days. Discussion. Articles regarding the creation of 3D printed custom ACL guides from the patients contralateral knee do not feature in current literature. There has been much research on custom guides for other