Advertisement for orthosearch.org.uk
Results 1 - 20 of 34
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 6 - 6
1 Dec 2022
Roversi G Nusiner F De Filippo F Rizzo A Colosio A Saccomanno M Milano G
Full Access

Recent studies on animal models focused on the effect of preserving tendon remnant of rotator cuff on tendon healing. A positive effect by combining tendon remnant preservation and small bone vents on the greater tuberosity in comparison with standard tendon-to-bone repair has been shown. The purpose of the present clinical study was to evaluate the efficacy of biologic augmentation of arthroscopic rotator cuff repair by maintaining tendon remnant on rotator cuff footprint combined with small bone vents of the greater tuberosity. A retrospective study was conducted. All patients who underwent arthroscopic rotator cuff repair associated with small bone vents (nanofractures) and tendon footprint preservation were considered eligible for the study. Inclusion criteria were: diagnosis of full-thickness rotator cuff tear as diagnosed at preoperative magnetic resonance imaging (MRI) and confirmed at the time of surgery; minimum 24-month of follow-up and availability of post-operative MRI performed not earlier than 6 months after surgery. Exclusion criteria were: partial thickness tears, irreparable tears, capsulo-labral pathologies, calcific tendonitis, gleno-humeral osteoarthritis and/or previous surgery. Primary outcome was the ASES score. Secondary outcomes were: Quick-DASH and WORC scores, and structural integrity of repaired tendons by magnetic resonance imaging (MRI) performed six months after surgery. A paired t-test was used to compare pre- and postoperative clinical outcomes. Subgroup analysis was performed according to tear size. Significance was set at p < 0.05. The study included 29 patients (M:F = 15:14). Mean age (+ SD) of patients was 61.7 + 8.9 years. Mean follow-up was 27.4 ± 2.3 months. Comparison between pre- and postoperative functional scores showed significant clinical improvement (p < 0.001). Subgroup analysis for tear size showed significant differences in the QuickDASH score (0.04). Particularly, a significant difference in the QuickDASH score could be detected between medium and large tears (p=0.008) as well as medium and massive lesions (p=0.04). No differences could be detected between large and massive tears (p= 0.35). Postoperative imaging showed healed tendons in 21 out of 29 (72%) cases. Preservation of tendon remnant combined with small bone vents in the repair of medium-to-massive full-thickness rotator cuff tears provided significant improvement in clinical outcome compared to baseline conditions with complete structural integrity in 72% of the cases


Several studies have evaluated the risk of peroneal nerve (PN) injuries in all-inside lateral meniscal repair using standard knee magnetic resonance imaging (MRI) with the 30 degrees flexed knee position which is different from the knee position during actual arthroscopic lateral meniscal repair. The point of concern is “Can the risk of PN injury using standard knee MRIs be accurately determined”. To evaluate and compare the risk of PN injury in all-inside lateral meniscal repair in relation to both borders of the popliteus tendon (PT) using MRIs of the two knee positions in the same patients. Using axial MRI studies with standard knee MRIs and figure-of-4 with joint fluid dilatation actual arthroscopic lateral meniscal repair position MRIs, direct lines were drawn simulating a straight all-inside meniscal repair device from the anteromedial and anterolateral portals to the medial and lateral borders of the PT. The distance from the tip of each line to the PN was measured. If a line touched or passed the PN, a potential risk of iatrogenic injury was noted and a new line was drawn from the same portal to the border of the PN. The danger area was measured from the first line to the new direct line along the joint capsule. In 28 adult patients, the closest distances from each line to the PN in standard knee MRI images were significantly shorter than arthroscopic position MRI images (all p-values < 0.05). All danger areas assessed in the actual arthroscopic position MRIs were included within the danger areas as assessed by the standard knee MRIs. We found that the standard knee MRIs can be used to determine the risk of peroneal nerve injury in arthroscopic lateral meniscal repair, although the risks are slightly overestimated


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 88 - 88
17 Apr 2023
Aljuaid M Alzahrani S Alzahrani A Filimban S Alghamdi N Alswat M
Full Access

Cervical spine facet tropism (CFT) defined as the facets’ joints angles difference between right and left sides of more than 7 degrees. This study aims to investigate the relationship between cervical sagittal alignment parameters and cervical spine facets’ tropism. A retrospective cross-sectional study carried out in a tertiary center where cervical spine magnetic resonance imaging (MRI) radiographs of patients in orthopedics/spine clincs were included. They had no history of spine fractures. Images’ reports were reviewed to exclude those with tumors in the c-spine. A total of 96 patients was included with 63% of them were females. The mean of age was 45.53± 12.82. C2-C7 cobb's angle (CA) and C2-C7 sagittal vertical axis (SVA) means were −2.85±10.68 and 1.51± 0.79, respectively. Facet tropism was found in 98% of the sample in at least one level on either axial or sagittal plane. Axial C 2–3 CFT and sagittal C4-5 were correlated with CA (r=0.246, P 0.043, r= −278, P 0.022), respectively. In addition, C2-C7 sagittal vertical axis (SVA) was moderately correlated with axial c2-3 FT (r= −0.330, P 0.006) Also, several significant correlations were detected in our model Cervical vertebral slopes and CFT at the related level. Nonetheless, high BMI was associated with multi-level and multiplane CFT with higher odd's ratios at the lower levels. This study shows that CFT at higher levels is correlated with increasing CA and decreasing SVA and at lower levels with decreasing CA. Obesity is a risk factor for CFT


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 12 - 12
11 Apr 2023
Swain L Shillabeer D Wyatt H Jonkers I Holt C Williams D
Full Access

Biplane video X-ray (BVX) – with models segmented from magnetic resonance imaging (MRI) – is used to directly track bones during dynamic activities. Investigating tibiofemoral kinematics helps to understand effects of disease, injury, and possible interventions. Develop a protocol and compare in-vivo kinematics during loaded dynamic activities using BVX and MRI. BVX (60 FPS) was captured whilst three healthy volunteers performed three repeats of lunge, stair ascent and gait. MRI scans were performed (Magnetom 3T Prisma, Siemens). 3D bone models of the tibia and femur were segmented (Simpleware Scan IP, Synopsis). Bone poses were obtained by manually matching bone models to X-rays (DSX Suite, C-Motion Inc.). Mean range of motion (ROM) of the contact points on the medial and lateral tibial plateau were calculated using custom MATLAB code (MathWorks). Results were filtered using an adaptive low pass Butterworth filter (Frequency range: 5-29Hz). Gait and Stair ascent activities from one participant's data showed increased ROM for medial-lateral (ML) translation in the medial compartment but decreased ROM in anterior-posterior (AP) translation when comparing against the same translations on the lateral compartment of the tibial plateau. Lunge activity showed increased ROM for both ML and AP translation in the medial compartment when compared with the lateral compartment. These results highlight the variability in condylar translations between different activities. Understanding healthy in-vivo kinematics across different activities allows the determination of suitable activities to best investigate the kinematic changes due to disease or injury and assess the efficacy of different interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 18 - 18
4 Apr 2023
Stanley A Jones G Edwards T Lex J Jaere M
Full Access

Knee pain is common, representing a significant socioeconomic burden. Caused by a variety of pathologies, its evaluation in primary-care is challenging. Subsequently, an over-reliance on magnetic resonance imaging (MRI) exists. Prior to orthopaedic surgeon referral, many patients receive no, or incorrect, imaging. Electronic-triage (e-triage) tools represent an innovative solution to address this problem. The primary aim of this study was to ascertain whether an e-triage tool is capable of outperforming existing clinical pathways to determine the correct pre-hospital imaging based on knee pain diagnosis. Patients ≥18 years with a new presentation of knee pain were retrospectively identified. The timing and appropriateness of imaging was assessed. A symptom-based e-triage tool was developed, using the Amazon LEXbotplatform, and piloted to predict five common knee pathologies and suggest appropriate imaging. 1462 patients were identified. 17% of arthroplasty patients received an ‘unnecessary MRI’, whilst 28% of arthroscopy patients did not have a ‘necessary MRI’, thus requiring a follow-up appointment, with a mean delay of three months (SD 2.6, range 0.2-20.2). Using NHS tariffs, a wasted cost through unnecessary/necessary MRIs and subsequent follow-up appointments was estimated at £45,816. The e-triage pilot was trialled with 41 patients (mean age:58.4 years, 58.5% female). Preliminary diagnoses were available for 34 patients. Using the highest proportion of reported symptoms in the corresponding group, the e-triage tool correctly identified three of the four knee pathologies. The e-triage tool did not correctly identify anterior cruciate ligament injuries (n=3). 79.2% of participants would use the tool again. A significant number of knee pathology patients received incorrect imaging prior to their initial hospital appointment, incurring delays and unnecessary costs. A symptom-based e-triage tool was developed, with promising pilot data and user feedback. With refinement, this tool has the potential to improve wait-times and referral quality, whilst reducing costs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 89 - 89
17 Apr 2023
Alzahrani S Aljuaid M Bazaid Z Shurbaji S
Full Access

A Morel-Lavallee lesion (MLL) is a benign cystic lesion that occurs due to injury to the soft-tissue envelope's perforating vascular and lymphatic systems, resulting in a distinctive hemolymphatic fluid accumulation between the tissue layers. The MLL has the potential to make a significant impact on the treatment of orthopaedic injuries. A 79-year-old male patient community ambulatory with assisting aid (cane) known case of Diabetes mellitus, hypertension, bronchial asthma and ischemic heart disease. He was brought to the Emergency, complaining of right hip discomfort and burning sensation for the last 5 days with no history of recent trauma at all. Patient had history of right trochanteric femur fracture 3 years ago, treated with DHS in a privet service. Clinical and Radiological assessment showed that the patient mostly has acute MLL due to lag screw cut out. We offered the patient the surgical intervention, but he refused despite explaining the risks of complications if not treated and preferred to receive the conservative treatment. Compression therapy management explained to him including biker's shorts (instructed to be worn full-time a day) and regular follow up in clinic. Symptom's improvement was reported by the patient in the subsequent visits. In the polytrauma patient, a delayed diagnosis of these lesions is conceivable due to the presence of more visible injuries. It's located over the greater trochanter more commonly, but sometimes in other areas such as the lower lumbar region, the thigh, or the calf. Incorrect or delayed diagnosis and care can have unfavorable outcomes such as infection, pseudocyst development, and cosmetologically deformity. Magnetic resonance imaging (MRI) and ultrasound will aid in MLL diagnosis. However, the effectiveness of MLL therapy remains debatable. We strongly believe that the MLL caused due to tangential shear forces applied to the soft tissue leads to accumulation of the blood and/or lymph between the subcutaneous and overlying fascia and it often misdiagnosed due to other distracting injuries. Nontheless, in our case we reported MLL occur due to internal pressure on the fascia caused by cut out of DHS lag screw


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 33 - 33
14 Nov 2024
Fallahy M Shaker F Ghanbari F Aslani MA Mohammadi S Behrouzieh S
Full Access

Introduction. Knee Osteoarthritis (KOA) is a prevalent joint disease requiring accurate diagnosis and prompt management. The condition occurs due to cartilage deterioration and bone remodeling. Ultrasonography has emerged as a promising modality for diagnosing KOA. Medial meniscus extrusion (MME), characterized by displacement of medial meniscus beyond the joint line has been recognized as a significant marker of KOA progression. This study aimed to explore potentials Ultrasound findings in timely detection of MME and compare it to magnetic resonance imaging (MRI) as a reference standard. Method. A comprehensive literature search was performed in 4 databases from inception to May 1 2024. Two independent reviewers, initiated screening protocols and selected the articles based on inclusion and exclusion criteria and then extracted the data. Meta-analysis was conducted using R 4.3.2 packages mada and metafor. Result. A total of 2500 articles from 4 databases was retrieved; however, following the application of inclusion and exclusion criteria 23 articles were finally extracted. These studies collectively encompassed a total of 777 patients with mean age of 53.2±7.4. The mean BMI calculated for patients was 28.31 ± 2.45. All patients underwent non-weight bearing knee ultrasonography in supine position with 0° flexion. The reported medial meniscus extrusion was 2.58 mm for articles using MRI and 2.65 mm for those using Ultrasound (MD: 0.05 ± 0.12, P= 0.65, I. 2. : 54%). Our meta-analysis revealed insignificant difference between US and MRI. (SMD: 0.03, 95% CI: -0.18 _0.23, P= 0.77, I. 2. : 56%) Meta analysis for diagnostic accuracy measures yielded a pooled sensitivity and specificity of 90.8% and 77% (95% CI: 84.2% – 94.8%, 35.5% – 95.3%, respectively, I. 2. : 44%). Conclusion. Our results indicate a close alignment in the accuracy of measurements obtained using Ultrasound modality. The narrow range suggests a minimal discrepancy in MME values between MRI and ultrasound, highlighting their comparable precision in diagnostic assessments


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 25 - 25
1 Dec 2022
Spina G Napoleone F Mancuso C Gasparini G Mercurio M Familiari FF
Full Access

Magnetic resonance imaging (MRI) is the gold standard for the diagnosis of the pathologies affecting the glenohumeral joint and the rotator cuff diseases. MRI allows to highlight anatomic discontinuities of both muscles and tendons. However, MRI diagnostic accuracy has not proven to be highly sensitive in distinguishing between a partial-thickness tear and a full-thickness rotator cuff tear. The purpose of this study was to determine if MRI under axial traction can be helpful in increasing MRI sensitivity to identify partial-thickness rotator cuff tears. The study included 10 patients (4 males and 6 females) who had clinical examination and MRI suggesting a partial-thickness rotator cuff tear. They were candidates for shoulder arthroscopy because of persistent symptoms after at least three months of conservative treatment. The patients underwent a new MRI (under axial traction: MRI-AT) with a 4-kg weight applied to the affected arm. Then the patients underwent arthroscopy to confirm the diagnosis. Patients with a suspected full-thickness rotator cuff tear were excluded from the study. Patients’ average age was 52.4 years, and the dominant side was affected in 77.7% of the cases. Preoperative Constant-Murley Score was 57. MRI-AT showed that 3 patients were affected by a complete tear of the rotator cuff, 3 patients by a partial-thickness rotator cuff tear and 4 patients had no lesion. The analysis of data showed that: under axial traction the subacromial space increased by 0,2 mm (P value = 0,001075), the superior glenohumeral space decreased by 2.4 mm (P value = 0,07414), the inferior glenohumeral space increased by 0.3 mm (P value = 0,02942), the acromial angle decreased by 1.9° (P value = 0,0002104) and the acromion-glenohumeral angle decreased by 0.3° (P-value = 0,01974). Two experienced evaluators analyzed previous standard MRI and MRI-AT scans in a double-blinded fashion, with inter-rater evaluation of all the images and measures. Intraclass correlation coefficient (ICC) has been utilized to assess the reliability of the measures performed by different operators. ICC always resulted in more than 0.7, showing a high concordance among values in the same group. A comparative evaluation between standard MRI and MRI-AT has been conducted to highlight possible discrepancies and this has been compared to intraoperative findings. Concordance of the values was 89% between standard MRI and MRI-AT and 100% between MRI under axial traction and intraoperative findings. This study showed a high correlation between the diagnosis achieved with MRI-AT and the intraoperative arthroscopic findings. The use of MRI-AT in clinical practice may improve the diagnostic sensitivity of this method to detect a partial-thickness rotator cuff tear


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 11 - 11
1 Dec 2022
Bergomi A Adriani M De Filippo F Manni F Motta M Saccomanno M Milano G
Full Access

Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair. The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05. Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups. The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 28 - 28
1 Dec 2021
Ahmed I Moiz H Carlos W Edwin C Staniszewska S Parsons N Price A Hutchinson C Metcalfe A
Full Access

Abstract. Objectives. Magnetic resonance imaging (MRI) is one of the most widely used investigations for knee pain as it provides detailed assessment of the bone and soft tissues. The aim of this study was to report the frequency of each diagnosis identified on MRI scans of the knee and explore the relationship between MRI results and onward treatment. Methods. Consecutive MRI reports from a large NHS trust performed in 2017 were included in this study. The hospital electronic system was consulted to identify whether a patient underwent x-ray prior to the MRI, attended an outpatient appointment or underwent surgery. Results. 4466 MRI knees were performed in 2017 with 71.2% requested in primary care and 28.1% requested in secondary care. The most common diagnosis was signs of arthritis (55.2%), followed by meniscal tears (42.8%) and ACL tears (8.3%). 49.4% of patients who had an MRI attended outpatients and 15.6% underwent surgery. The rate of knee surgery was significantly higher for patients who had their scans requested in secondary care (32.9% vs 8.9%, p < 0.001). Conclusion. The rate of surgical intervention following MRI is low and given these results it seems unlikely that the scan changes practice in most cases. The rate of surgery and outpatient follow up was significantly higher in scans requested by secondary care. We urge clinicians avoid wasteful use of MRI and recommend the use of plain radiography prior to MRI where arthritis may be present


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 109 - 109
1 Dec 2020
AKTAS E CLEMENTS A CHAMBERLAIN C VANDERBY R MURPHY W
Full Access

Although multifunctional delivery systems can potentially improve safety and efficacy of therapeutic protein delivery in the biological treatment of injured tissues, ability to track and manipulate protein delivery systems in vivo to ensure localization at the treatment site is still a concern. We hypothesized that incorporating superparamagnetic iron oxide (SPIO) into calcium phosphate (CaP) coated β-tricalcium phosphate (β-TCP) microparticles would allow for Magnetic Resonance Imaging (MRI) based tracking in vivo and SPIO incorporation would not impact the biological activity of proteins delivered with these microparticles. To address the efficacy and limitations in therapeutic protein delivery, a CaP coated microparticle which incorporates superparamagnetic iron oxide (SPIO-CaP-MP) was created and used in a rat knee medial collateral ligament. The system has trifunctional properties: (1) it is trackable using magnetic resonance imaging (MRI), (2) it can be manipulated with a magnetic field, (3) it can release active proteins in the injury site. SPIO-Ca-MPs were formed on β-tricalcium phosphate cores. Using MRI, SPIO-CaP-MPs were visible in T2 weighted sequences as an area of hypointesive signal. SPIO-CaP-MPs could be visualized and remained localized for at least 15 days after injection into the medial collateral ligament. Recombinant human basic fibroblast growth factor delivered with SPIO-CaP-MPs stimulated the proliferation of human dermal fibroblasts. Finally, SPIO-CaP-MPs could be localized to a bar magnet when suspended in solution. Taken together, these results suggest that SPIO-CaPMPs could be useful for protein delivery applications in the treatment of ligament injury that may benefit from externally controlled localization and MRI-based tracking


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 51 - 51
1 Dec 2020
Khan MM Pincher B Pacheco R
Full Access

Aims and objectives. Our aim was to evaluate the indications for patients undergoing magnetic resonance imaging (MRI) of the knee prior to referral to an orthopaedic specialist, and ascertain whether these scans altered initial management. Materials and Method. We retrospectively reviewed all referrals received by a single specialist knee surgeon over a 1-year period. Patient demographics, relevant history, examination findings and past surgical procedures were documented. Patients having undergone MRI prior to referral were identified and indications for the scans recorded. These were reviewed against The NHS guidelines for Primary Care Physicians to identify if the imaging performed was appropriate in each case. Results. A total of 261 patients were referred between 1. st. July 2018 and 30. th. June 2019. 87/261 patients underwent MRI of the knee joint prior to referral. The mean patient age was 53 years with predominance of male patients (52 verses 35 females). 21/87 patients (24%) underwent the appropriate imaging prior to referral with only 13% of patients undergoing x-ray imaging before their MRI. In cases where MRI was not indicated, patients waited an average of 12 weeks between their scan and a referral being sent to the specialist knee surgeon. Conclusion. 76% of patients referred to orthopaedics had inappropriate MRI imaging arranged by their primary care physician. For a single consultant's referrals over 1 year these unnecessary MRI scans cost the NHS £13,200. Closer adherence to the guidelines by primary care physicians would result in a financial saving for the NHS, faster referral times and a more effective use of NHS resources


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 118 - 118
1 Mar 2021
Jeuken R Roth A Peters M Welting T Rhijn L Thies J Emans P
Full Access

Focal knee resurfacing implants (FKRIs) are typically intended to treat focal cartilage defects in middle-aged patients. All currently available FKRIs are (partly) composed of metal, which potentially leads to degeneration of the opposing articulating cartilage and hampers follow-up using magnetic resonance imaging (MRI). The purpose of this study was to investigate the in vivo osseointegration process of a novel non-degradable thermoplastic polycarbonate-urethane (TPU) osteochondral implant. Bi-layered implants measuring 6 mm in diameter, with a double-curvature to match the approximate curvature of the goat medial femoral condyle were fabricated. TPU implants were composed of an articulating Bionate® II 80A top layer, and a Bionate® 75D bottom layer (DSM Biomedical, Geleen, the Netherlands) which is intended to osseointegrate. A biphasic calcium phosphate coating formulation, optimized during a prior in vitro study, was applied to half of the TPU implants, while the other half was left uncoated. Bi-layered metal implants (articulating cobalt-chromium top layer and titanium bottom layer) were used as positive control implants. Eight implants per group were implanted bilaterally in the medial femoral condyle of the stifle joints in 12 Dutch milk goats. 18F-sodium fluoride (18F-NaF) positron emission tomography-computed tomography (PET-CT) scanning was performed at 3 and 12 weeks postoperatively, and the corrected maximum standard uptake values (cSUVmax) was calculated to assess the peri-implant bone metabolism. After sacrifice 12 weeks postoperatively, bone histomorphometric analysis was performed to assess the bone-to-implant contact area (BIC). Student's T-test was used in case of normal distribution and the Mann-Whitney-U-test was used in case of abnormal distribution for comparison of BIC and cSUVmax. The BIC value of 10.27 ± 4.50% (mean ± SD) for the BCP-coated TPU implants was significantly (P=0.03) higher than the 4.50 ± 2.61% for the uncoated TPU implants. The uncoated TPU implants scored significantly (P=0.04) lower than the BIC of 12.81 ± 7.55% for the metal implants, whereas there was no significant difference between BCP-coated TPU implants and the metal implants (P=0.68). There was a strong correlation between the cSUVmax values and the BIC values at 12 weeks (Pearson's R=0.74, P=0.001). The cSUVmax values significantly decreased between 3 and 12 weeks for the metal implants (p=0.04). BCP-coated TPU implants followed a similar trend but did not reach statistical significance (p=0.07). cSUVmax in the uncoated TPU implants did not show a significant difference between the time-points (p=0.31). Osseointegration of BCP-coated TPU implants did not significantly differ from metal implants. 18F-NaF PET-CT is a feasible modality to assess osseointegration patterns and showed a similar trend between the BCP-coated and metal implants. Hence, an implant fully composed of TPU may avoid the typical metal-related drawbacks of currently available FKRIs. Long-term follow-up studies are advocated to address the effects of the implant to the opposing cartilage, and are therefore warranted


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 51 - 51
1 Apr 2018
Kamatsuki Y Furumatsu T Miyazawa S Fujii M Kodama Y Hino T Ozaki T
Full Access

Purpose. Injuries of the meniscal attachments can lead to meniscal extrusion. We hypothesized that the extent of lateral meniscal extrusion (LME) was associated with the severity of the lateral meniscus posterior root tear (LMPRT). This study aimed to evaluate the relationship between preoperative LME and arthroscopic findings of LMPRT in knees with anterior cruciate ligament (ACL) injury. Methods. Thirty-four knees that had LMPRTs with concomitant ACL injuries on arthroscopy were evaluated. Patients were divided into two groups, partial and complete root tears, via arthroscopic findings at the time of ACL reconstruction. We retrospectively measured preoperative LMEs using magnetic resonance imaging (MRI). Statistical analysis was performed using the Mann-Whitney U-test and Chi-square test. Results. Twenty-three knees had partial LMPRTs (type 1). Complete LMPRTs were observed in 11 knees (type 2, 2 knees; type 3, 2 knees; and type 4, 7 knees). In the partial LMPRT group, the average LME was 0.43±0.78 mm. In the complete LMPRT group, the average extrusion was 1.99±0.62 mm. A significant difference between these groups was observed in the preoperative LMEs (P<0.01). The receiver operating curve analysis identified an optimal cutoff point of 1.05 mm for the preoperative LME. This LME cutoff had a sensitivity of 100% and specificity of 85% for complete LMPRT. Conclusion. This study demonstrated that preoperative LMEs were larger in complete LMPRTs associated with ACL injuries than in partial LMPRTs. Our results suggest that preoperative MRI-detected LME may be a useful indicator for estimating LMPRT severity in knees with ACL injury


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 73 - 73
1 Apr 2017
Hurley R Barry C Bergin D Shannon F
Full Access

Background. The anatomy of the human body has been studied for centuries. Despite this, recent articles have announced the presence of a new knee ligament- the anterolateral ligament. It has been the subject of much discussion and media commentary. Previous anatomical studies indicate its presence, and describe its location, origin, course and insertion. Magnetic resonance imaging (MRI) is the best and most commonly used investigation to assess the ligamentous structure of the knee. To date, most MRI knee reports make no mention of the anterolateral ligament. The aim of this study was to assess for the presence of the anterolateral ligament using MRI, and to describe the structure if visualised. Methods. All right knee MRIs performed on a Siemens Magnetom Espree 1.5 Tesla scanner in Merlin Park Hospital over a 4 year period were retrospectively analysed. Patients born before 1970, or with reported abnormalities were excluded. The normal MRIs were then analysed by a consultant radiologist specialising in musculoskeletal imaging. Measurements on origin, insertion, course and length were noted. Results. 942 right knee MRIs were performed in the time period. 62 were classed as normal, and within the specified age range. 10 were randomly sampled. Of these the ligament was visible on all 10 MRIs, best viewed in the coronal plane. The average length (visible in 8/10) was 28.88mm +/− 5.14mm. The origin (visible in all 10) was 2.25mm +/− 0.39mm. The insertion (visible in 9/10) was 1.93mm +/− 0.424. The mid thickness was 1.87mm +/− 0.2mm. Conclusions. This study indicates that the ALL is a discrete, visible structure on MRI. This furthers the evidence of the presence of the ALL and also provides information that may be beneficial in future studies, and assessment of knee injuries. Level of evidence. 4


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 57 - 57
1 Apr 2018
Angrisani N Warwas DP Behrens P Janßen HC Kietzmann M Reifenrath J
Full Access

After the implantation of endoprotheses or osteosynthesis devices, implant-related infections are one of the major challenges. The surface of implants offers optimal conditions for the formation of a biofilm. Effective carrier systems for the delivery of adequate therapeutics would reduce the concentrations needed for successful treatment and improve cure rates. In cancer diagnosis and therapy, magnetic nanoparticles are concentrated in the target area by an external magnetic field. For orthopaedic applications, in vitro examinations showed that the addition of a magnetic implant in combination with an external magnetic field could increase the amount of MNPSNPs that accumulated in direct vicinity to the implant. The present examinations implemented an electromagnet to increase magnetic field strength and should show if the in vitro set up can be transferred to an in vivo mouse model. Additionally, the loading capacity of the MNPSNPs with enrofloxacin and its release kinetics were determined. Fluorescein-isothiocyanate (FITC) was covalently attached to MNPSNPs. For the in vitro set up, a peristaltic pump was used to establish a closed circuit which contained the MNPSNP dispersion and a magnetic platelet. After 5 minutes fluid samples were taken from the area around the magnetic platelet and analysed using a microplate reader. For the in vivo set up, a BALB/c mouse was implanted subcutaneously with the metallic platelet at the hind leg. The MNPSNP dispersion was injected into the tale vein and the hind leg of the mouse was placed immediately in a magnetic field of 1.9 T. After one week the implant was retrieved and examined by confocal laser scanning microscopy (CLSM). Liver, spleen and kidneys of the mouse were examined by magnetic resonance imaging (MRI). The loading capacity of the MNPs with enrofloxacin was examined by quantification of the enrofloxacin content in the incubation and washing solution after incubation. The release kinetics weres tested in PBS using UV/Vis-spectrometry. The solution in the remaining tube contained no detectable MNPs while the concentration in the vicinity of the platelet was 150 µg/ml. The mouse showed no clinical adverse effects. The CLSM examination revealed a considerable accumulation of the MNPs at the implant surface. MRI could show neither accumulated MNPs nor changes of organ structure. The loading capacity of the MNPs for enrofloxacin was approximately 95 µg/mg. A burst release of nearly a third of the loaded antibiotic occurred within the first 6 hours followed by a further steady release. Conclusion. Loading and release of enrofloxacin showed appropriate results. For future studies antibiotics like rifampicin or vancomycin will be implemented. This first in vivo trial demonstrated an implant-directed targeting of the MNPs and successfully transferred the principle into an in vivo model so that a main study with statistically significant animal numbers has started including histological examinations


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 61 - 61
1 Aug 2013
Ferguson K Higgs Z Tait G
Full Access

Magnetic resonance imaging (MRI) continues to become more widely accessible as an investigation, with an increasing number of scans being performed in the outpatient setting for suspected shoulder pathology. We performed a retrospective review of all shoulder MRI scans performed in an orthopaedic outpatient setting in a district general hospital between October 2010 and October 2011. We also reviewed the medical notes for these patients. 75 MRI Shoulder scans were performed on 74 patients. In 5 cases (7%), no other form of imaging was performed prior to MRI scan. 11 patients (15%) had no provisional diagnosis included in the referral. The nature of referral, indication for MRI and subsequent management of these patients was also examined. Our findings may support the use of guidelines for requesting MRI scans of the shoulder in outpatients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 47 - 47
1 Oct 2016
Halai M Jamal B Robinson P Qureshi M Kimpton J Syme B McMillan J Holt G
Full Access

Three distal femoral axes have been described to aid in alignment of the femoral component; the Trans Epicondylar Axis (TEA), the Posterior Condylar Axis (PCA) and the Antero Posterior (AP) axis. Our aim was to identify if there was a reproducible relationship between the axes which would aid alignment of the femoral component. This is the first study compare all three distal femoral axes with each other using magnetic resonance imaging (MRI) in a Caucasian population. Our sample group represents real life patients awaiting total knee arthroplasty (TKA), as opposed non-arthritic or cadaveric knees. We identified the relationship between these rotational axes by performing MRI scans on 89 patients awaiting TKA with patient-specific instrumentation. Measurements were taken by two observers. Patients had a mean age of 62.5 years (range 32–91). 51 patients were female. The mean angle between the TEA and the AP axis was 92.78° with a standard deviation of 2.51° (range 88° – 99°). The mean angle between the AP axis and the PCA was 95.43° with a standard deviation of 2.75° (range 85° – 105°). The mean angle between the TEA and the PCA was 2.78° with a standard deviation of 1.91° (range 0° – 10°). We conclude that while there is a reproducible relationship between the differing femoral axes, there is a significant range in the relationship between the femoral axes. This range may lead to greater inaccuracy than has previously been appreciated when defining the rotation of the femoral component. There is most variation between the PCA and the AP axis. The TEA's relationship with the PCA and AP appears important in defining rotation. Due to the well accepted difficulty in defining the TEA intra-operatively, there may be a role for patient-specific instrumentation in TKA surgery with pre-operative MRI


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 20 - 20
1 Apr 2018
Kuroda Y Akiyama H Matsuda S
Full Access

Introduction. For many years, minimally invasive joint-preserving regenerative therapy has been desired for the early stages of osteonecrosis of the femoral head (ONFH). In an animal study using adult rabbits, we reported that a single local injection of rhFGF-2-impregnated gelatin hydrogel, which has superior slow-release characteristics, suppresses the progression of femoral head necrosis. The purpose of this study was to evaluate the safety and clinical outcomes of a single local administration of rhFGF-2-impregnated gelatin hydrogel for the precollapse stage of ONFH. Patients and Methods: Ten patients with femoral heads up to precollapse stage 2 underwent a single local administration of 800-µg rhFGF-2-impregnated gelatin hydrogel and were followed up for two years. The eligibility criteria were age between 20 and 80 years and presence of ONFH at precollapse stage 1 or 2 according to the classification system for ONFH developed by the Japanese Investigation Committee of Health and Welfare. Primary outcomes included adverse events and complications. Secondary outcomes included changes in Harris Hip Scores (HHS), visual analog scale pain scores (VAS), the University of California, Los Angeles (UCLA) activity rating scores, radiological changes as determined via radiographs, computed tomography (CT) scans, and magnetic resonance imaging (MRI) of the hip joint. Results: We included five men (five hips) and five women (five hips), with a mean age of 39.8 years (range: 29–53 years) at the time of surgery. Eight patients had bilateral ONFH, three had already undergone THA on the contralateral side. Eight patients were receiving treatment with corticosteroid therapy, and two patients overused alcohol. Stage 1 and 2 disease was present in one and nine patients, respectively. One patient each had type A, type B, and type C1 disease, whereas seven patients had a type C2 lesion. All Adverse events were recovered without problem. The surgery was performed with a minimally invasive technique based core decompression (1 cm of skin incision), and walking was allowed from the day after surgery. Mean clinical scores improved significantly after three year compared with before surgery (before vs. after: VAS for pain, 21.2 vs. 5.3 mm; UCLA activity score 5.5 vs. 6.6; HHS, 81.0 vs. 98.4 points, respectively). There was only one case of femoral head collapse, and it had the greatest necrosis volume fraction and was considered to be in the early collapse stage at the time of operation. The other nine cases did not involve ONFH stage progression, and collapse was prevented. CT images and recent MRI postoperatively confirmed bone regeneration and reduction of the necrotic area. Conclusion: Clinical application of rhFGF-2-impregnated gelatin hydrogel for patients with precollapse stage of ONFH was feasible and safe. Our research is ongoing, further phase II multiple center study has been started in January 2016


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 42 - 42
1 Apr 2018
Gabler C Gierschner S Lindner T Tischer T Bader R
Full Access

The biomechanical evaluation of tendon repair with collagen-based scaffolds in rat model is a common method to determine the functional outcome of the tested material. We introduced a magnetic resonance imaging (MRI) approach to verify the biomechanical test data. In present study different collagen scaffolds for tendon repair were examined. Two collagen test materials: based on bovine stabilized collagen, chemically cross-linked with oriented collagenous fibres (material 1) and based on porcine dermal extracellular matrix, with no cross-linking (material 2) were compared. The animal study was approved by the local review board. Surgery was performed on male Sprague-Dawley rats with a body weight of 400 ± 19 g. Each rat underwent a 5 mm transection of the right Achilles tendon. The M. plantaris tendon was removed. The remaining tendon ends were re-joined with a 5 mm scaffold of either the material 1 or 2. Each scaffold material was sutured into place with two single stiches (Vicryl 4–0, Ethicon) each end. A total of 16 rats (n= 8 each group) were observed for 28 days follow up. The animals were sacrificed and hind limbs were transected proximal to the knee joint. MRI was performed using a 7 Tesla scanner (BioSpec 70/30, Bruker). T2-weighted TurboRARE sequences with an in-plane resolution of 0.12 mm and a slice thickness of 0.7 mm were analysed. All soft and hard tissues were removed from the Achilles tendon-calcaneus-foot complex before biomechanical testing. Subsequently, the specimens were fixed in a materials testing machine (Z1.0, Zwick, Ulm, Germany) for tensile testing. All tendons were preloaded with 1 N and subsequently stretched at a rate of 1 mm/s until complete failure was observed. Non-operated tendons were used as a control (n=4). After 28 postoperative days, MRI demonstrated that four scaffolds (material 1: n=2, material 2: n=2) were slightly dislocated in the proximal part of hind limb. In total five failures of reconstruction could be detected in the tendon repairs (material 1: n=3, material 2: n=2). Tendons augmented with the bovine material 1 showed a maximum tensile load of 57.9 ± 17.9 N and tendons with porcine scaffold material 2 of 63.1 ± 19.5 N. The native tendons demonstrated only slightly higher loads of 76.6 ± 11.6 N. Maximum failure load of the tendon-scaffold construct in both groups did not differ significantly (p < 0.05). Stiffness of the tendons treated with the bovine scaffold (9.9 ± 3.6 N/mm) and with the porcine scaffold (10.7 ± 2.7 N/mm) showed no differences. Stiffness of the native healthy tendon of the contralateral site was significantly higher (20.2 ± 6.6 N/mm, p < 0.05). No differences in the mechanical properties between samples of both scaffold groups could be detected, regardless of whether the repaired tendon defect has failed or the scaffold has been dislocated. The results show that MRI is important as an auxiliary tool to verify the biomechanical outcome of tendon repair in animal models