Aims. The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR. Methods. A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs. Results. Acetabular version was significantly lower and measurements of external rotation of the hemipelvis were significantly increased in the AR group compared to the control group. The AR group also had increased evidence of anterior projection of the iliac wing in the sagittal plane. The acetabular orientation angles were more retroverted in the supine compared to standing position, and the change in acetabular version correlated with the change in sagittal
Aims. Patients with abnormal spinopelvic mobility are at increased risk for instability. Measuring the change in sacral slope (ΔSS) can help determine spinopelvic mobility preoperatively. Sacral slope (SS) should decrease at least 10° to demonstrate adequate posterior pelvic tilt. There is potential for different ΔSS measurements in the same patient based on sitting posture. The purpose of this study was to determine the effect of sitting posture on the ΔSS in patients undergoing total hip arthroplasty (THA). Methods. In total, 51 patients undergoing THA were reviewed to quantify the variability in preoperative spinopelvic mobility when measuring two different sitting positions using SS for planning. Results. A total of 32 patients had standardized relaxed sitting radiographs, while 35 patients had standardized flexed sitting images. Of the 32 patients with relaxed sitting views, the mean ΔSS was 20.7° (SD 8.9°). No patients exhibited an increase in SS during relaxed sitting (i.e.
Purpose. Patients with acetabular dysplasia demonstrate altered biomechanics during gate and other activities. We hypothesized that these patients exhibit a compensatory increase in the
Aims. The purpose of this study was to evaluate spinopelvic mechanics from standing and sitting positions in subjects with and without femoroacetabular impingement (FAI). We hypothesize that FAI patients will experience less flexion at the lumbar spine and more flexion at the hip whilst changing from standing to sitting positions than subjects without FAI. This increase in hip flexion may contribute to symptomatology in FAI. Patients and Methods. Male subjects were prospectively enrolled to the study (n = 20). Mean age was 31 years old (22 to 41). All underwent clinical examination, plain radiographs, and dynamic imaging using EOS. Subjects were categorized into three groups: non-FAI (no radiographic or clinical FAI or pain), asymptomatic FAI (radiographic and clinical FAI but no pain), and symptomatic FAI (patients with both pain and radiographic FAI). FAI was defined as internal rotation less than 15° and alpha angle greater than 60°. Subjects underwent standing and sitting radiographs in order to measure spine and femoroacetabular flexion. Results. Compared with non-FAI controls, symptomatic patients with FAI had less flexion at the spine (mean 22°, . sd. 12°, vs mean 35°, . sd. 8°; p = 0.04) and more at the hip (mean 72°, . sd. 6°, vs mean 62°, . sd. 8°; p = 0.047). Subjects with asymptomatic FAI had more spine flexion and similar hip flexion when compared to symptomatic FAI patients. Both FAI groups also sat with more
Variation in pelvic tilt during postural changes may affect functional alignment. The primary objective of this study was to quantify the changes in lumbo-pelvic-femoral alignment from sitting to standing in patients undergoing THA. 144 patients were enrolled. Standing and sitting radiographs using the EOS imaging system were analyzed preoperatively and 1-year postoperatively. Pelvic incidence (PI), lumbar lordosis (LL), sacral slope (SS), proximal femoral angle (PFA) and spine/femoroacetabular flexion were determined. 38 patients had multilevel DDD (26%). Following THA, patients sat with increased
Osteochondroplasty procedure for cam deformity provides excellent outcomes on alleviating pain, improving quality of life and clinical function in femoroacetabular impingement syndrome (FAIS) patients. Although medium-term outcomes on gait biomechanics have been reported, it is unclear how it would translate to better hip muscle forces and joint loading in high range of motion tasks. The purpose of this study was to compare the muscle forces and hip joint contact forces (HCF) during a squat task in individuals before and after cam-FAIS surgical correction. Ten cam-FAIS patients prior and 2-years after osteochondroplasty, and 10 BMI- age- and sex-matched healthy control participants (CTRL) underwent 3D motion and ground reaction forces capture while performing a deep squatting task. Muscle and HCF were estimated using musculoskeletal modeling and comparisons were done using statistical parametric mapping (SPM). Postoperatives squatted down with a higher
Many studies describe the use of the Ilizarov ring fixator for lower limb lengthening and for the management of the 3-dimensional lower limb deformities in achondroplasia, and most confirm the efficacy of this technique. However, long term follow up of these achondroplastic patients is lacking. Most studies have focused on magnitude of lengthening, treatment time required and complications, but no study has analyzed the long term postoperative condition of these patients using an objective, functional method such as gait analysis. Nineteen (19) achondroplastic patients, 12 males and 7 females, aged 19–38 years (mean 27.3 y) who have undergone tibia and femur lengthening, using the Ilizarov method, at the age of 9–19 years (mean 12.6 y), were evaluated 5–19 years (mean 10.1 y) after their last surgery, using 3-dimensional gait analysis. Nineteen (19) normal, height-matched subjects were used as controls. The VICON Nexus 8 Camera System was used to accurately measure spatiotemporal characteristics (walking velocity, stride length, step length, cadence) and kinematics (range of motion) of lower limb joints. Statistical comparison of deformity parameters between achondroplastic patients and normal population was done using the student t- test. A level of p<0.05 was considered statistically significant. Walking velocity, step length and stride length were statistically significantly decreased (p<0.05) in achondroplastic patients compared to normal population values. The achondroplastic group presented with excessive
Aims. The aims of this study were to measure sagittal standing and sitting lumbar-pelvic-femoral alignment in patients before and following total hip arthroplasty (THA), and to consider what preoperative factors may influence a change in postoperative pelvic position. Patients and Methods. A total of 161 patients were considered for inclusion. Patients had a mean age of the remaining 61 years (. sd. 11) with a mean body mass index (BMI) of 28 kg/m. 2. (. sd. 6). Of the 161 patients, 82 were male (51%). We excluded 17 patients (11%) with spinal conditions known to affect lumbar mobility as well as the rotational axis of the spine. Standing and sitting spine-to-lower-limb radiographs were taken of the remaining 144 patients before and one year following THA. Spinopelvic alignment measurements, including sacral slope, lumbar lordosis, and pelvic incidence, were measured. These angles were used to calculate lumbar spine flexion and femoroacetabular hip flexion from a standing to sitting position. A radiographic scoring system was used to identify those patients in the series who had lumbar degenerative disc disease (DDD) and compare spinopelvic parameters between those patients with DDD (n = 38) and those who did not (n = 106). Results. Following THA, patients sat with more
Abstract. Introduction. Recent reports show that spinopelvic mobility influences outcome following total hip arthroplasty. This scoping review investigates the relationship between spinopelvic parameters (SPPs) and symptomatic femoroacetabular impingement (FAI). Methods. A systematic search of EMBASE, PubMed and Cochrane for literature related to SPPs and FAI was undertaken as per PRISMA guidelines. Clinical outcome studies and prospective/retrospective studies investigating the role of SPPs in symptomatic FAI were included. Review articles, case reports and book chapters were excluded. Information extracted pertained to symptomatic cam deformities, pelvic tilt, acetabular version, biomechanics of dynamic movements and radiological FAI signs. Results. The search identified 42 papers for final analysis out of 1168 articles investigating the link between SPPs and pathological processes characteristic of FAI. Only one (2.4%) study was of level 1 evidence, five (11.9%) studies) were level 2, 17 (40.5%) were level 3 and 19 (45.2%) were level 4. Three studies associated FAI pathology with a greater pelvic incidence (PI), while four associated it with a smaller PI.
Aims. Concurrent hip and spine pathologies can alter the biomechanics of spinopelvic mobility in primary total hip arthroplasty (THA). This study examines how differences in pelvic orientation of patients with spine fusions can increase the risk of dislocation risk after THA. Patients and Methods. We identified 84 patients (97 THAs) between 1998 and 2015 who had undergone spinal fusion prior to primary THA. Patients were stratified into three groups depending on the length of lumbar fusion and whether or not the sacrum was involved. Mean age was 71 years (40 to 87) and 54 patients (56%) were female. The mean body mass index (BMI) was 30 kg/m. 2. (19 to 45). Mean follow-up was six years (2 to 17). Patients were 1:2 matched to patients with primary THAs without spine fusion. Hazard ratios (HR) were calculated. Results. Dislocation in the fusion group was 5.2% at one year versus 1.7% in controls but this did not reach statistical significance (HR 1.9; p = 0.33). Compared with controls, there was no significant difference in rate of dislocation in patients without a sacral fusion. When the sacrum was involved, the rate of dislocation was significantly higher than in controls (HR 4.5; p = 0.03), with a trend to more dislocations in longer lumbosacral fusions. Patient demographics and surgical characteristics of THA (i.e. surgical approach and femoral head diameter) did not significantly impact risk of dislocation (p > 0.05). Significant radiological differences were measured in mean
We studied the results of multi-level surgical intervention for children with cerebral palsy. Thirty patients, aged 7–16 years, with spastic diplegia (n=20), or spastic hemiplegia (n=10) were studied prospectively by gait analysis. Multilevel surgery included a combination of psoas lengthening, medial hamstring lengthening, rectus femoris transfer and gastrocnemius lengthening +/− foot surgery or femoral derotation osteotomies. Gait analyses were carried out pre-op and at 6 and 24 months post-op. Children with spastic diplegia increased their walking velocity by an average of 20% at two years (p<
0.05). Mean stride length increased from 89cm pre-op to 102cm at two years (p<
0.05) with similar improvements in both groups of children. Maximum knee extension in stance improved from an average 17.5 degrees flexion pre-operatively to an average 5 degrees flexion postoperatively (p<
0.05). Peak knee flexion in swing was maintained and the timing improved. Peak ankle dorsiflexion in stance was unchanged following surgery but the timing of peak ankle dorsiflexion was normalised to late stance (from 24% of cycle pre-operatively to 48% of cycle post-operatively (norm = 48%). Average maximum hip extension in stance did not change. The mean
Introduction. A deep squat (DS) is a challenging motion at the level of the hip joint generating substantial reaction forces (HJRF). During DS, the hip flexion angle approximates the functional range of hip motion. In some hip morphologies this femoroacetabular conflict has been shown to occur as early as 80° of hip flexion. So far in-vivo HJRF measurements have been limited to instrumented hip implants in a limited number of older patients performing incomplete squats (< 50° hip flexion and < 80° knee flexion). Clearly, young adults have a different kinetical profile with hip and knee flexion ranges going well over 100 degrees. Since hip loading data on this subgroup of the population is lacking and performing invasive measurements would be unfeasible, this study aimed to report a personalised numerical model solution based on inverse dynamics to calculate realistic in silico HJRF values during DS. M&M. Fifty athletic males (18–25 years old) were prospectively recruited for motion and morphological analysis. DS motion capture (MoCap) acquisitions and MRI scans of the lower extremities with gait lab marker positions were obtained. The AnyBody Modelling System (v6.1.1) was used to implement a novel personalisation workflow of the AnyMoCap template model. Bone geometries, semi-automatically segmented from MRI, and corresponding markers were incorporated into the template human model by an automated nonlinear morphing. Furthermore, a state-of-the-art TLEM 2.0 dataset, included in the Anybody Managed Model Repository (v2.0), was used in the template model. The subject-specific MoCap trials were processed to compute squat motion by resolving an overdeterminate kinematics problem. Inverse dynamics analyses were carried out to compute muscle and joint reaction forces in the entire body. Resulting hip joint loads were validated with measured in-vivo data from Knee bend trials in the OrthoLoad library. Additionally,
Aims. The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. Patients and Methods. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51). Results. Three patients were excluded from the analysis leaving 47 patients
with complete follow-up data. Of the 47 patients, 46 achieved radiological
union and one progressed to an asymptomatic nonunion. Of the remaining patients,
45 required supplementary posterior fixation with percutaneous iliosacral
screws, 2 of which required sacral plating. The incidence of injury
to the lateral femoral cutaneous nerve (LFCN) was 34%. The rate
of infection was 2%. There were no other significant complications.
Without this treatment, 44 patients (94%) would have needed unilateral
or bilateral open reduction and plate fixation extending laterally
to the hip joint. Conclusion. The anterior pelvic internal fixator reduces the need for extensive
open surgery and is a useful addition to the armamentarium for the
treatment of
Objectives. The spinopelvic relationship (including pelvic incidence) has been shown to influence pelvic orientation, but its potential association with femoroacetabular impingement has not been thoroughly explored. The purpose of this study was to prove the hypothesis that decreasing pelvic incidence is associated with increased risk of cam morphology. Methods. Two matching cohorts were created from a collection of cadaveric specimens with known pelvic incidences: 50 subjects with the highest pelvic incidence (all subjects > 60°) and 50 subjects with the lowest pelvic incidence (all subjects < 35°). Femoral version, acetabular version, and alpha angles were directly measured from each specimen bilaterally. Cam morphology was defined as alpha angle > 55°. Differences between the two cohorts were analysed with a Student’s t-test and the difference in incidence of cam morphology was assessed using a chi-squared test. The significance level for all tests was set at p < 0.05. Results. Cam morphology was identified in 47/100 (47%) femurs in the cohort with pelvic incidence < 35° and in only 25/100 (25%) femurs in the cohort with pelvic incidence > 60° (p = 0.002). The mean alpha angle was also greater in the cohort with pelvic incidence < 35° (mean 53.7°, . sd. 10.7° versus mean 49.7°, . sd. 10.6°; p = 0.008). Conclusions. Decreased pelvic incidence is associated with development of cam morphology. We propose a novel theory wherein subjects with decreased pelvic incidence compensate during gait (to maintain optimal sagittal balance) through
Aims. The pelvis rotates in the sagittal plane during daily activities.
These rotations have a direct effect on the functional orientation
of the acetabulum. The aim of this study was to quantify changes
in pelvic tilt between different functional positions. Patients and Methods. Pre-operatively, pelvic tilt was measured in 1517 patients undergoing
total hip arthroplasty (THA) in three functional positions – supine,
standing and flexed seated (the moment when patients initiate rising
from a seated position). Supine pelvic tilt was measured from CT
scans, standing and flexed seated pelvic tilts were measured from standardised
lateral radiographs.
Aims. The aims of the study were to determine the differences in spinopelvic mobility between a cohort of hip OA patients and a control group for the 1) standing to relaxed-seated and 2) standing to deep-seated task. Methods. A cohort of 40 patients with end-stage hip OA and a control group of 40 subjects, matched for age, gender and BMI were prospectively studied. Clinical data and lateral view radiographs in different positions were assessed. Sagittal spinopelvic mobility was calculated as the change when moving from the standing to relaxed-seated and standing to deep-seated positions for the lumbar lordosis angle, pelvic tilt and pelvic-femoral angle. Results. When moving from the standing to sitting position, hip OA patients demonstrated less hip flexion (52±18 vs. 69±11, p<0.001), an increased posterior pelvic tilt (23±13 vs. 12±9, p<0.001) and more flexion of the lumbar spine (22±15 vs. 14±11, p=0.01). Similarly, when moving from the standing to deep-seated position, hip OA patients demonstrated also less hip flexion (64±21 vs. 84±18, p<0.001), accompanied by a posterior and not an
Aim. The aim of the study was to characterise gait in patients with achondroplasia post lengthening. Patients/Materials and Methods. Full kinematic and kinetic lower limb gait analysis was performed at the Sheffield Children's Hospital gait laboratory, Sheffield, using a Vicon system (6 cameras working at 50Hz) and processed using Plug In Gait modelling software. The lengthened Achondroplasia group (n=11, mean age = 24.5 ± 6.1) had previously undergone surgical lengthening of the legs. The lengthened Achondroplasia group was compared to a control group of 11 adult normal subjects. Results. Averaged sagittal plane kinematics are shown in Figure 1. The key sagittal plane characteristics we found were increased
Aims. Long-term clinical outcomes for ceramic-on-ceramic (CoC) bearings
are encouraging. However, there is a risk of squeaking. Guidelines
for the orientation of the acetabular component are defined from
static imaging, but the position of the pelvis and thus the acetabular
component during activities associated with edge-loading are likely
to be very different from those measured when the patient is supine.
We assessed the functional orientation of the acetabular component. Patients and Methods. A total of 18 patients with reproducible squeaking in their CoC
hips during deep flexion were investigated with a control group
of 36 non-squeaking CoC hips. The two groups were matched for the
type of implant, the orientation of the acetabular component when
supine, the size of the femoral head, ligament laxity, maximum hip
flexion and body mass index. . Results. The mean functional anteversion of the acetabular component at
the point when patients initiated rising from a seated position
was significantly less in the squeaking group than in the control
group, 8.1° (-10.5° to 36.0°) and 21.1° (-1.9° to 38.4°) respectively
(p = 0.002). . Conclusion. The functional orientation of the acetabular component during
activities associated with posterior edge-loading are different
from those measured when supine due to patient-specific pelvic kinematics.
Individuals with a large
Purpose: The aim of this study was to see if there is any relationship between a positive hamstring shift test, which is a measure of knee flexion deformity after eliminating
Introduction. The direct anterior approach (DAA) for total hip arthroplasty continues to gain popularity. Consequently, more procedures are being performed with the patient supine. The approach often utilizes a special leg positioner to assist with femoral exposure. Although the supine position may seem to allow for a more reproducible pelvic position at the time of cup implantation, there is limited evidence as to the effects on pelvic tilt with such leg positioners. Furthermore, the DAA has led to increased popularity of specific softwares, ie. Radlink or JointPoint, that facilitate the intra-op analysis of component position from fluoroscopy images. The aim of this study was to assess the difference in cup orientation measurements between intra-op fluoroscopy and post-op CT. Methods. A consecutive series of 48 DAA THAs were performed by a single surgeon in June/July 2018. All patients received OPS. TM. pre-operative planning (Corin, UK), and the cases were performed with the patient supine on the operating table with the PURIST leg positioning system (IOT, Texas, USA). To account for variation in pelvic tilt on the table, a fluoroscopy image of the hemi-pelvis was taken prior to cup impaction, and the c-arm rotated to match the shape of the obturator foramen on the supine AP Xray. The final cup was then imaged using fluoroscopy, and the radiographic cup orientation measured manually using Radlink GPS software (Radlink, California, USA). Post-operatively, each patient received a low dose CT scan to measure the radiographic cup orientation in reference to the supine coronal plane. Results. Mean cup orientation from intra-op fluoro was 38° inclination (32° to 43°) and 24° anteversion (20° to 28°). Mean cup orientation from post-op CT was 40° inclination (29° to 47°) and 30° anteversion (22° to 38°). Cups were, on average, 6° more anteverted and 2° more inclined on post-op CT than intra-op. These differences were statistically significant, p<0.001. All 48 cups were more anteverted on CT than intra-op. There was no statistical difference between pre- and post-op supine pelvic tilt (4.1° and 5.1° respectively, p = 0.41). Discussion. We found significant differences in cup orientation measurements performed from intra-op fluoro to those from post-op CT. This is an important finding given the attempts to adjust for pelvic tilt during the procedure. We theorise two sources of error contributing to the measurement differences. Firstly, the under-compensation for the