Introduction. Ilizarov fixators are reliant on tensioned fine
Introduction. In my paediatric Orthopaedic practice I use Kirchner
Introduction. During its conception, Ilizarov advocated a fine
Introduction. Critical limb ischemia (CLI) is the reduced blood flow in the arteries of the lower extremities. It is a serious form of peripheral arterial disease, or PAD. If left untreated the complications of CLI will result in amputation of affected limb. The treatment experience of diabetic foot with transverse tibial transport was carried out by Ilizarov technique. Madura foot ulcer is not a common condition. It disturbs the daily activities of the patient. Pain swelling with multiple nodules with discharging sinus with discoloration(blackening) of the affected area is the main problem. Materials and Methods. We treated total case: 36 from Jan. 2003 – Jan. 2020 (17yrs.). Among these-. TAO- 20. Limb Ishchemia- 5. Diabetic Foot- 9. Mycetoma pedis- 2. Infected sole and dorsum of the foot- 5. Results. Transverse corticotomy and
Aim. To evaluate bacterial adhesion and biofilm formation to metallic cerclage
The use of ultrasound-guided
Introduction. Circular frame fixation has become a cornerstone of non-union and deformity management since its inception in the 1950s. As a consequence of modularity and heterogenous patient and injury factors, the prediction of the mechanobiological environment within a defect is subject to wide variations in practice. Given these wide range of confounding variables, clinical and cadaveric experimentation is close to impossible and frame constructs are based upon clinician experience. The Finite Element Analysis (FEA) method provides a powerful tool to numerically analyse mechanics. This work aims to develop an FEA model of a tibial defect and predict the mechanical response within the construct. Materials and Methods. The geometry of a tibia was acquired via CT and a series of bone defects were digitally created in the tibial diaphysis. A 4-ring, 10-wire Ilizarov fixator was constructed using 180mm stainless steel rings and 1.8mm stainless steel
Purpose of Study. Bicondylar tibial plateau fractures are serious injuries to a major weight bearing joint. These injuries are often associated with severe soft tissue injuries that complicate the surgical management. This retrospective study evaluates the management of these high-energy injuries with the use of limited open reduction and fine
Early methods of treating high-energy tibial plateau fractures by open reduction and internal fixation led to high infection rates and complications. Alternative treatment methods include minimally invasive techniques and implants, external fixator stabilisation (monolateral and circular) and temporary external fixation followed by delayed definitive surgery. A clear understanding of the different fracture types is critical in achieving optimum results with minimally invasive techniques. The Chertsey classification system is based on the direction of force at the time of injury and helps with surgical planning. There are three groups: valgus, varus or axial fracture patterns. 124 tibial plateau fractures have been surgically treated in our hospital since 1995; there were 62 valgus, 14 varus and 48 axial type fracture patterns. Seventy-nine underwent open reduction with internal fixation, and forty-five had an Ilizarov frame. For valgus fractures the average IOWA knee score was 88 if internally fixed or 86 with an Ilizarov frame, range of motion was 140 and 131 degrees and time to union was 81 versus 126 days respectively. Varus fractures had an IOWA score of 83 (ORIF) and 95 (Ilizarov), ROM of 138 and 130 degrees and time to union of 95 versus 82 days. For axial fractures the average IOWA knee score was 85 (ORIF) compared to 82 (Ilizarov), the ROM was 124 degrees for both groups and time to union was 102 days and 141 days respectively. Deep vein thrombosis occurred in 9% of cases with an Ilizarov and one patient required a total knee replacement for painful post-traumatic osteoarthritis. The infection rate for those internally fixed was 2.5%, three patients required a total knee replacement and 2.5% suffered a DVT. Our results are comparable to the literature and the Chertsey classification of tibial plateau fractures helps with surgical planning.
Currently the debate continues in definitive fixation method for complex tibial plateau fractures. The aim of surgical management remains prevention of further damage to the articular cartilage, whilst avoiding iatrogenic risks - Low Risk Surgery (LRS). The purpose of this study was to determine the functional impact, clinical radiological outcome following tibial plateau fractures treated with either external fixation or internal fixation. 124 Schatzker IV-VI tibial plateau fractures were reviewed following surgical fixation. Fractures analysed included 24 type IV, 20 type V and 80 type VI tibial plateau fractures. The majority of Schatzker IV fractures were treated with internal fixation, but 67 of 80 Schatzker VI fractures were treated with the Ilizarov method. The average IOWA knee score, was 86 (16 to 100) and the average range of motion was 133 degrees (60 to 150). There were no differences between the circular fixator group and the internal fixation group in terms of range of motion or IOWA scores. There were comparable functional outcomes and complication rates between both groups. In summary patients with high energy tibial plateau fracture treated with internal or external fixation, have a good chance of achieving satisfactory long term knee function.
Introduction. External fixators are attached to bones with percutaneous pins and
Abstract. A study was done to test the strength of various configurations of tension band wiring (TBW) and we report clinical results of ‘Horizontal Figure of Eight TBW’ (H – 8 TBW). In an experimental lab, a model of the fractured patella was mounted on a Nene tensile testing machine and various configurations of TBWs were tested in different positions of Kirschner wires. The strength of TBW and various knots securing the ends of
Introduction. The objective of this study is to report the first cases of femoral lengthening in children using Ilizarov fixator. Materials and Methods. We carried out a retrospective study about the cases of femoral lengthening done in 2010 to 2020 in our BARI-ILIZAROV Orthopaedic centre Dhaka. Results. 48 lengthening were done during this period using Ilizarov fixator. The procedure was done incongenital bone diseases in 20 cases and after a distal femoral epiphysiodesis in 10 cases. The mean age at surgery was 12.8 years. Lengthening was required in all patients and an axis correction was required in 16 of 26 cases. The mean lengthening was 5.9 cm. The healing index was 45.5 day/cm (25.5–62). We noticed 8 knee stiffness and 5 broken
Introduction. Pilon fractures are complex, high-energy, intra-articular fractures of the distal tibia. Achieving good outcomes is challenging due to fracture complexity and extensive soft tissue damage. The purpose of this study was to determine the long-term functional and clinical outcomes of definitive management with fine
Introduction. Charcot neuroarthropathy is a limb threatening condition and the optimal surgical strategy for limb salvage in gross foot deformity remains unclear. We present our experience of using fine
The treatment of paediatric supracondylar humeral fractures is likely one of the first procedures involving X-ray guided
Augmented reality simulators offer opportunities for practice of orthopaedic procedures outside of theatre environments. We developed an augmented reality simulator that allows trainees to practice pinning of paediatric supracondylar humeral fractures (SCHF) in a radiation-free environment at no extra risk to patients. The simulator is composed of a tangible child's elbow model, and simulated fluoroscopy on a tablet device. The treatment of these fractures is likely one of the first procedures involving X-ray guided
Over 500 supracondylar humerus fractures (SCHF) are treated at our institution each year. Our standard post-operative pathway includes a 3-week visit for splint removal,
Introduction. Treatment of non-union in open tibial fractures Gustilo-Anderson(GA)-3A/3B fractures remains a challenging problem. Most of these can be dealt using treatment methods that requires excision of the non-union followed by bone grafting, masquelet technique, or acute shortening. Circular fixators with closed distraction or bone transport also remains a useful option. However, sometimes due to patient specific factors these cannot be used. Recently antibiotic loaded bone substitutes have been increasingly used for repairing infected non-unions. They provide local antibiotic delivery, fill dead space, and act as a bone conductive implant, which is resorted at the end of a few months. We aimed to assess the outcome of percutaneous injection of bone substitute while treating non-union of complex open tibial fractures. Materials & Methods. Three cases of clinical and radiological stiff tibial non-union requiring further intervention were identified from our major trauma open fracture database. Two GA-3B cases, treated with a circular frame developed fracture-related-infection(FRI) manifesting as local cellulitis, loosened infected
Introduction. Percutaneous EndoProsthetic Osseointegration for Limbs (PEPOL) facilitates improved quality of life (QOL) and objective mobility for most amputees discontent with their traditional socket prosthesis (TSP) experience. Some amputees desiring PEPOL have residual bone much shorter than the currently marketed press-fit implant lengths of 14–16 cm, potentially a risk for failure to integrate. We report on the techniques used, complications experienced, the management of those complications, and the overall mobility outcomes of seven patients who had femur distraction osteogenesis (DO) with a Freedom nail followed by PEPOL. Materials & Methods. Retrospective evaluation of a prospectively maintained database identified nine patients (5 females) who had transfemoral DO in preparation for PEPOL with two years of follow-up after PEPOL. Six patients had traumatic causes of amputation, one had perinatal complications, one was performed to manage necrotizing fasciitis and one was performed as a result of osteosarcoma. Results. The average age at which DO commenced was 39.4±15.9 years, and seven patients had their amputation more than ten years prior (average 25.5±18.8 years). The residual femurs on average started at 102.2±39.7 mm and were lengthened 58.1±20.7 mm, 98±45% of goal (99±161% of the original bone length). Five patients (56%) had a complication requiring additional surgery: four events of inadequate regenerate were managed with continued lengthening to desired goal followed by autograft placement harvested from contralateral femur reaming; one patient had the cerclage