Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 53 - 53
2 Jan 2024
Ghaffari A Clasen P Boel R Kappel A Jakobsen T Kold S Rahbek O
Full Access

Wearable inertial sensors can detect abnormal gait associated with knee or hip osteoarthritis (OA). However, few studies have compared sensor-derived gait parameters between patients with hip and knee OA or evaluated the efficacy of sensors suitable for remote monitoring in distinguishing between the two. Hence, our study seeks to examine the differences in accelerations captured by low-frequency wearable sensors in patients with knee and hip OA and classify their gait patterns. We included patients with unilateral hip and knee OA. Gait analysis was conducted using an accelerometer ipsilateral with the affected joint on the lateral distal thighs. Statistical parametric mapping (SPM) was used to compare acceleration signals. The k-Nearest Neighbor (k-NN) algorithm was trained on 80% of the signals' Fourier coefficients and validated on the remaining 20% using 10-fold cross-validation to classify the gait patterns into hip and knee OA. We included 42 hip OA patients (19 females, age 70 [63–78], BMI of 28.3 [24.8–30.9]) and 59 knee OA patients (31 females, age 68 [62–74], BMI of 29.7 [26.3–32.6]). The SPM results indicated that one cluster (12–20%) along the vertical axis had accelerations exceeding the critical threshold of 2.956 (p=0.024). For the anteroposterior axis, three clusters were observed exceeding the threshold of 3.031 at 5–19% (p = 0.0001), 39–54% (p=0.00005), and 88–96% (p = 0.01). Regarding the mediolateral axis, four clusters were identified exceeding the threshold of 2.875 at 0–9% (p = 0.02), 14–20% (p=0.04), 28–68% (p < 0.00001), and 84–100% (p = 0.004). The k-NN model achieved an AUC of 0.79, an accuracy of 80%, and a precision of 85%. In conclusion, the Fourier coefficients of the signals recorded by wearable sensors can effectively discriminate the gait patterns of knee and hip OA. In addition, the most remarkable differences in the time domain were observed along the mediolateral axis


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 98 - 98
1 Jul 2014
Palmer A Fernquest S Hamish L Pollard T McNally E Wilson D Wilson D Madler B Carr A Glyn-Jones S
Full Access

Summary. The dGEMRIC index correlates more strongly with the pattern of radiographic joint space narrowing in hip osteoarthritis at five year follow-up than morphological measurements of the proximal femur. It therefore offers potential to refine predictive models of hip osteoarthritis progression. Introduction. Longitudinal general population studies have shown that femoroacetabular impingement increases the risk of developing hip osteoarthritis, however, morphological parameters have a low positive predictive value. Arthroscopic debridement of impingement lesions has been proposed as a potential strategy for the prevention of osteoarthritis, however, the development of such strategies requires the identification of individuals at high risk of disease progression. We investigated whether delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) predicts disease progression. This imaging modality is an indirect measure of cartilage glycosaminoglycan content. Patients and Methods. 34 asymptomatic individuals from a longitudinal cohort study (sibkids) were assessed at baseline with the collection of Patient Reported Outcome Measures (PROMs), anteroposterior and cross-table lateral radiographs, 3D morphological MRI, and dGEMRIC at 3T of their index hip. A dGEMRIC index was calculated as a ratio of the anterosuperior acetabular cartilage T1 relaxation time and the total femoral and acetabular cartilage T1 relaxation time. 29 individuals were followed up at 5 years for repeat assessment (average age 51 years and range 36 to 67). Radiological measurements were made by a single observer using in house Hipmorf software. Radiographic disease progression was assessed using minimum joint space width (JSW), lateral sourcil JSW, and medial sourcil JSW. These were measured on baseline and five year follow-up anteroposterior radiographs with an intra-observer ICC of 0.916. Alpha angle measurements were made by the same observer on radiographs and MRI radial slices with an intra-observer ICC of 0.926. Results. Mean minimum JSW for the cohort fell by 0.16mm over five years (p=0.024). Baseline dGEMRIC index did not correlate with change in minimum JSW (r=0.031 p=0.873). There was a moderate correlation between baseline dGEMRIC and the direction of JSW loss (change in JSW at the lateral sourcil minus change in JSW at the medial sourcil) (r=0.561 p=0.002). There was a weak correlation between the change in Non-Arthritic Hip Score and baseline dGEMRIC (r=0.256 P=0.180). Maximum alpha angle measured on baseline MRI radial slices did not correlate with change in minimum JSW and weakly correlated with the direction of JSW narrowing (r=0.273 p=0.160). Conclusion. A low dGEMRIC index indicates reduced glycosaminoglycan concentration in the anterosuperior acetabular cartilage compared with the total femoral and acetabular cartilage. This correlates with lateral JSW narrowing relative to medial JSW narrowing as osteoarthritis progresses. The dGEMRIC index correlates better with osteoarthritis progression than alpha angle measurements and offers the potential to refine a predictive model for osteoarthritis progression to aid patient selection for clinical trials


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 16 - 16
1 Nov 2021
Frydendal T Christensen R Mechlenburg I Mikkelsen LR Overgaard S Ingwersen KG
Full Access

Introduction and Objective. Hip osteoarthritis (OA) is the leading cause for total hip arthroplasty (THA). Although, being considered as the surgery of the century up to 23% of the patients report long-term pain and deficits in physical function and muscle strength may persist after THA. Progressive resistance training (PRT) appear to improve several outcomes moderately in patients with hip OA. Current treatment selection is based on low-level evidence as no randomised controlled trials have compared THA to non-surgical treatment. The primary objective of this trial is to determine the effectiveness of THA followed by standard care compared to 12 weeks of supervised PRT followed by 12 weeks of optional unsupervised PRT, on changes in hip pain and function, in patients with severe hip OA after 6 months. Materials and Methods. This is a protocol for a multicentre, parallel-group, assessor blinded, randomised controlled superiority trial. Patients aged ≥50 years with clinical and radiographic hip OA found eligible for THA by an orthopaedic surgeon will be randomised to THA or PRT (allocation 1:1). The primary outcome will be change in patient-reported hip pain and function, measured using the Oxford Hip Score. Key secondary outcomes will be change in the Hip disability and Osteoarthritis Outcome Score subscales, University of California Los Angeles Activity Score, 40-meter fast-paced walk test, 30-second chair stand test, and number of serious adverse events. Results. The trial has been approved by The Regional Committees on Health Research Ethics for Southern Denmark (Project-ID: S-20180158) in February 2019 and registration was performed at . ClinicalTrials.gov. (NCT04070027) in August 2019. Recruitment was initiated on the 2. nd. of September 2019 and the final deadline will be on the 30. th. of June 2021, or when a sample size of 120 patients has been accomplished. Conclusions. The results of the current trial are expected to enable evidence-based recommendations, which may be used to facilitate the shared-decision making process in the discussion of treatment strategy for the individual patient with severe hip OA. All results will be presented in peer-reviewed scientific journals and international conferences


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 47 - 47
1 Aug 2012
Merle C Waldstein W Pegg E Streit M Gotterbarm T Aldinger P Murray D Gill H
Full Access

In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the reliability and accuracy of predicting three-dimensional (3-D) FO as measured on computed tomography (CT) from measurements performed on standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs and corresponding CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 29-57) kg/m2) with primary end-stage hip osteoarthritis were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding AP pelvis radiographs and CT scans. Inter- and intra-observer reliability of the measurement methods were evaluated using intra-class correlation coefficients (ICC). To predict 3-D FO from AP pelvis measurements, the entire cohort was randomly split in two groups and gender specific linear regression equations were derived from a subgroup of 250 patients (group A). The accuracy of the derived prediction equations was subsequently assessed in a second subgroup of 100 patients (group B). In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. FO was underestimated by 14% on AP pelvis radiographs compared to CT (5.4mm, 95%CI: 4.8-6.0mm, p<0.001) and both parameters demonstrated a linear correlation (r=0.642, p<0.001). In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The results of the present study suggest that femoral offset can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating and may improve offset and limb length restoration in THA without the routine performance of CT


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 27 - 27
1 Mar 2013
Okoro T Stewart C Al-Shanti N Lemmey A Maddison P Andrew J
Full Access

Aim. This study aimed to assess whether the severity of symptoms (assessed with the Oxford Hip Score (OHS)) can relate to the levels of mRNA expression of markers for muscle inflammation (tumour necrosis factor alpha (TNFα), interleukin 6 (IL-6)) in the proximal vastus lateralis (VL) of patients with severe OA undergoing THR. Methods. Following local research ethics approval and informed consent, 17 patients were prospectively recruited. Muscle biopsies were obtained from the proximal VL (accessed through the surgical wound) intraoperatively whilst the OHS questionnaire was administered preoperatively. mRNA expression for TNFα and IL-6 was assessed using the reverse transcriptase polymerase chain reaction (RT-PCR). The median OHS was used for stratification, with patients above the median classed as having moderate symptoms (MS) and those below classed as having severe symptoms (SS). The effect of SS on muscle inflammation was assessed with relative quotient (RQ) comparison of SS vs. MS mRNA expression. Results. Patients recruited were (mean (SD)) 65.3(8.8) years old in men (n=9) and 59.8 (13.3) years old in women (n=9). The median OHS was 24 (range 10–32) with SS < 24 (n=10) and MS ≥ 24 (n=7). In comparison to the MS group, the SS group had increased TNFα expression (+28% (RQ=1.28, p=0.35)) with reduced IL-6 expression (−44% (RQ=0.56, p=0.35), though neither of these reached statistical significance. Conclusions. Muscle inflammation is not clearly correlated to symptoms in this group. Preoperative subjective functional deficit appears independent of muscle inflammation in patients with hip osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 78 - 78
1 Aug 2012
Merle C Waldstein W Gregory J Goodyear S Aspden R Aldinger P Murray D Gill H
Full Access

In uncemented total hip arthroplasty (THA), the optimal femoral component should allow both maximum cortical contact with proximal load transfer and accurate restoration of individual joint biomechanics. This is often compromised due to a high variability in proximal femoral anatomy. The aim of this on-going study is to assess the variation in proximal femoral canal shape and its association with geometric and anthropometric parameters in primary hip OA.

In a retrospective cohort study, AP-pelvis radiographs of 98 consecutive patients (42 males, 56 females, mean age 61 (range:45-74) years, BMI 27.4 (range:20.3-44.6) kg/m2) who underwent THA for primary hip OA were reviewed. All radiographs were calibrated and femoral offset (FO) and neck-shaft-angle (NSA) were measured using a validated custom programme. Point-based active shape modelling (ASM) was performed to assess the shape of the inner cortex of the proximal femoral meta- and diaphysis. Independent shape modes were identified using principal component analysis (PCA). Hierarchical cluster analysis of the shape modes was performed to identify natural groupings of patients. Differences in geometric measures of the proximal femur (FO, NSA) and demographic parameters (age, height, weight, BMI) between the clusters were evaluated using Kruskal-Wallis one-way-ANOVA or Chi-square tests, as appropriate.

In the entire cohort, mean FO was 39.0 mm, mean NSA was 131 degrees. PCA identified 10 independent shape modes accounting for over 90% of variation in proximal femoral canal shape within the dataset. Cluster Analysis revealed 6 shape clusters for which all 10 shape modes demonstrated a significantly different distribution (p-range:0.000-0.015). We observed significant differences in age (p=0.032), FO (p<0.001) and NSA (p<0.001) between the clusters. No significant differences with regard to gender or BMI were seen.

Our preliminary analysis has identified 6 different patterns of proximal femoral canal shape which are associated with significant differences in femoral offset, neck-shaft-angle and age at time of surgery. We are currently evaluating the entire dataset of 345 patients which will allow a comprehensive classification of variation in proximal femoral shape and joint geometry. The present data may optimise preoperative planning and improve future implant design in THA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 103 - 103
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Patients who are Jehovah's witnesses do not accept blood transfusions. Thus, total hip arthroplasty can be challenging in this group of patients due to the potential for blood loss. Multiple strategies have been developed in order to prevent blood loss. A 76-year-old female, Jehovah's witness medicated with a platelet antiaggregant, presented to the emergency department after a fall from standing height. Clinically, she had pain mobilizing the right lower limb and radiological examination revealed an acetabular fracture with femoral head protrusion and ipsilateral isquiopubic fracture. Skeletal traction was applied to the femur during three weeks and no weight bearing was maintained during the following weeks. Posteriorly, there was an evolution to hip osteoarthritis with necrosis of the femoral head. The patient was submitted to surgery six months after the initial trauma, for a total hip arthroplasty. The surgery was performed with hypotensive anaesthesia, careful surgical technique and meticulous haemostasis and there was no need for blood transfusion. Posteriorly, there was a positive clinical evolution with progressive improvement on function and deambulation. Total hip arthroplasty may be safely carried out with good clinical outcomes in Jehovah's witnesses, without the need for blood transfusion, if proper perioperative precautions are taken, as has already been shown in previous studies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 93 - 93
11 Apr 2023
de Angelis N Beaule P Speirs A
Full Access

Femoro-acetabular impingement involves a deformity of the hip joint and is associated with hip osteoarthritis. Although 15% of the asymptomatic population exhibits a deformity, it is not clear who will develop symptoms. Current diagnostic imaging measures have either low specificity or low sensitivity and do not consider the dynamic nature of impingement during daily activities. The goal of this study is to determine stresses in the cartilage, subchondral bone and labrum of normal and impinging hips during activities such as walking and sitting down. Quantitative CT scans were obtained of a healthy Control and a participant with a symptomatic femoral cam deformity (‘Bump’). 3D models of the hip were created from automatic segmentation of CT scans. Cartilage layers were added so the articular surface was the mid-line of the joint. Finite element meshes were generated in each region. Bone elastic modulus was assigned element-by-element, calculated from CT intensity converted to bone mineral density using a calibration phantom. Cartilage was modelled as poroelastic, E=0.467 MPa, v=0.167, and permeability 3×10. -16. m. 4. /N s. The pelvis was fixed while rotations and contact forces from Bergmann et al. (2001) were applied to the femur over one load cycle for walking and sitting in a chair. All analyses were performed in FEBio. High shear stresses were seen near the acetabular cartilage-labrum junction in the Bump model, up to 0.12 MPa for walking and were much higher than in the Control. Patient-specific modelling can be used to assess contact and tissue stresses during different activities to better understand the risk of degeneration in individuals, especially for activities that involve high hip flexion. The high stresses at the cartilage labrum interface could explain so-called bucket-handle tears of the labrum


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 9 - 9
1 Dec 2022
Olivotto E Mariotti F Castagnini F Favero M Oliviero F Evangelista A Ramonda R Grigolo B Tassinari E Traina F
Full Access

Hip Osteoarthritis (HOA) is the most common joint disorder and a major cause of disability in the adult population, leading to total hip replacement (THR). Recently, evidence has mounted for a prominent etiologic role of femoroacetabular impingement (FAI) in the development of early OA in the non-dysplastic hip. FAI is a pathological mechanical process, caused by abnormalities of the acetabulum and/or femur leading to damage the soft tissue structures. FAI can determine chondro-labral damage and groin pain in young adults and can accelerate HOA progression in middle-aged adults. The aim of the study was to determine if the presence of calcium crystal in synovial fluid (SF) at the time of FAI surgery affects the clinical outcomes to be used as diagnostic and predictive biomarker. 49 patients with FAI undergoing arthroscopy were enrolled after providing informed consent; 37 SFs were collected by arthrocentesis at the time of surgery and 35 analyzed (66% males), median age 35 years with standard deviation (SD) 9.7 and body mass index (BMI) 23.4 kg/m. 2. ; e SD 3. At the time of surgery, chondral pathology using the Outerbridge score, labral pathology and macroscopic synovial pathology based on direct arthroscopic visualization were evaluated. Physical examination and clinical assessment using the Hip disability & Osteoarthritis Outcome Score (HOOS) were performed at the time of surgery and at 6 months of follow up. As positive controls of OA signs, SF samples were also collected from cohort of 15 patients with HOA undergoing THR and 12 were analysed. 45% FAI patients showed CAM deformity; 88% presented labral lesion or instability and 68% radiographic labral calcification. 4 patients out of 35 showed moderate radiographic signs of OA (Kellegren-Lawrence score = 3). Pre-operative HOOS median value was 61.3% (68.10-40.03) with interquartile range (IQR) of 75-25% and post-operative HOOS median value 90% with IQR 93.8-80.60. In both FAI and OA patients the calcium crystal level in SFs negatively correlated with glycosaminoglycan (component of the extracellular matrix) released, which is a marker of cartilage damage (Spearman rho=-0.601, p<0.001). In FAI patients a worst articular function after surgery, measured with the HOOS questionnaire, was associated with both acetabular and femoral chondropathy and degenerative labral lesion. Moreover, radiographic labral calcification was also significantly associated with pain, worst articular function and labral lesion. Calcium crystal level in SFs was associated with labral lesions and OA signs. We concluded that the levels of calcium crystals in FAI patients are correlated with joint damage, OA signs and worst post-operative outcome. The presence of calcium crystals in SF of FAI patients might be a potential new biomarker that might help clinicians to make an early diagnosis, evaluate disease progression and monitor treatment response


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 59 - 59
17 Nov 2023
Yang I Buchanan R Al-Namnam N Li X Lucas M Simpson AH
Full Access

Abstract. Background. Ultrasonic cutting of bone boasts many advantages over alternatively powered surgical instruments, including but not limited to: elimination of swarf, reduced reaction forces, increased precision in cutting and reduced adjacent soft tissue damage, reduced post-operative complications such as bleeding and bone fracture, reduced healing time, reduced intra-operative noise and ease of handling. Despite ultrasonic cutting devices being well established in oral and maxillofacial surgery, applications in orthopaedic surgery are more niche and are not as well understood. The aim of this study was to investigate the cutting speed (mm/s) and cutting forces (N) of orthopaedic surgeons using a custom-designed state of the art ultrasonic cutting tool to cut fresh human bone samples. Methods. A setup based on the Robot Operating System (ROS) and AprilTag was designed to track and to record the real time position of the ultrasonic cutting tool in space. Synchronised load cell axial force readings of three separate orthopaedic surgeons during ultrasonic cutting were recorded. Each surgeon was asked to find a comfortable position that reflects as close as possible their clinical handling of a cutting instrument used in surgery, and to perform two cuts in each of three samples of human cortical bone. Bone samples were obtained following ethical approval from an institutional review board (ethics approval number: SR1342) and prior informed consent was obtained from all patients. Bone samples were extracted from the femoral neck region of three hip osteoarthritis patients. During cutting, surgeons were allowed a total cutting time of one minute and cutting was conducted using an ultrasonic tool with frequency of a 35kHz (35.7 µm peak to peak displacement amplitude) under constant irrigation using a MINIPULS® 3 Peristaltic pump (38 revolutions per minute) using Phosphate-Buffered Saline (PBS) at 25°C. From the recorded data, the average instantaneous cutting velocity was calculated and the maximum cutting force was identified. Results. All surgeons assumed a back-and-forth cutting motion, variation in the applied cutting force was observed. The average vertical cutting speed, axial cutting force and cutting depth across all surgeons and all samples was 1.64 mm/s, 1.91 N and 0.73 mm, respectively. While increasing the axial cutting force resulted in a deeper cut, overloading of the ultrasound transducer occurred when the tool advanced too quickly into the bone tissue during cutting. The exact force threshold, or the optimal speed at which the surgeon can maintain a constant force during cutting, requires further investigation. Conclusions. In this study, all surgeons cut using a back-and-forth cutting motion, with variation in the applied cutting force which may ultimately inform which clinical applications in orthopaedic engineering are most suitable for this technology. Applying too much force caused overloading of the ultrasound transducer, which is a limitation with the current cutting tool. The results from this study may facilitate the eventual uptake of ultrasonic cutting tools for application in orthopaedic surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 72 - 72
1 Nov 2021
Zampogna B
Full Access

Hyaluronic acid (HA) is responsible for the viscoelastic properties of synovial fluid and cartilage. Compared to healthy joints, synovial fluid in osteoarthritic joints contains HA of lower concentration and molecular weight. Hyaluronic acid hybrid complexes are composed by long and short HA chains linked by H bonds. These rheological characteristics and viscoelastic properties were produced by thermal patented process without chemical modification. Chondroitin sulfate (CS) is one of the essential components of the articular cartilage matrix and plays a key role in cartilage's mechanical and elastic properties. Biotechnological chondroitin (CB) is produced through fermentative/biotechnological processes and, unlike CS, is not sulfated. It has been shown that CB to play a more significant role in the phenotypic maintenance of chondrocytes than chondroitin sulfate and increases their viability and proliferation. A recent A Single-Arm, Open-Label, Pilot Study was conducted to evaluate the safety and efficacy of a single-dose intra-articular injection of Hybrid Hyaluronic acid and Sodium Chondroitin in the Treatment of Symptomatic Hip Osteoarthritis. A single injection of HS-SC was well tolerated and safe in the treatment of symptomatic hip OA. The treatment demonstrated a rapid significant improvement in pain (VAS) and function (Lequesne's Index) up to 6 months of follow-up


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 49 - 49
1 Jan 2017
Augat P Varady P Glitsch U
Full Access

Hip osteoarthritis (OA) is a disorder of high socio-economic relevance. The causes of hip osteoarthritis are multifactorial; however, the epidemiological literature regularly cites occupational tasks, such as heavy lifting and carrying, as a risk factor for the development of hip OA. The level of mechanical stresses upon the hip joint caused by occupational tasks remain largely unclear, however. This project sought to quantify the levels of stresses upon the hip joint during occupational tasks. In particular we were interested in comparing load as well as stress levels from everyday activities with occupational tasks typically performed by blue collar workers. Sectors and occupational activities presenting a high potential for stress upon the hip joint were identified by means of a survey conducted among accident insurance institutions. Lifting, carrying and load transfer (25 to 50 kg), ladder climbing and stair climbing (without additional load and with an additional load of 25 kg) were selected from among these sectors and activities for the purpose of the study. Laboratory measurements were performed in which motion capturing and a range of force measurement apparatus were used to record and evaluate the performance of the selected tasks by 12 skilled workers from a number of sectors. multi-body simulation was used to calculate the stress in the form of hip-joint contact forces. The contact pressures and their geometric distribution on the cartilage surfaces of the hip joint were then calculated from these results by means of finite-element analysis. This produced an indicator for the strain upon the hip joint. The highest hip-joint forces, at (637±148)% of the body weight, occurred during handling of the 50 kg load. This corresponded to 1.7 times the stress arising during walking, at (368±78)% of the body weight. Significantly higher hip-joint forces compared to those arising during walking were observed for the carrying of loads of 40 kg and 50 kg, the handling of loads of 25 kg, 40 kg and 50 kg, and stair climbing with an additional load of 25 kg. Maximum contact pressures of 24.1 MPa were computed during the finite-element analysis (lifting of 50 kg); only very small regions of the joint surface were however affected by these high pressures. During walking, the maximum pressure reached 15 MPa. The results obtained provide a quantitative overview of the strains upon the hip joint during occupational and everyday tasks. They constitute an aid to future quantitative exposure assessments in a range of sectors and occupational fields, and thus contribute to improving estimation of the relevance of stresses of occupational origin to the incidence of hip OA


Bone & Joint Research
Vol. 6, Issue 7 | Pages 439 - 445
1 Jul 2017
Sekimoto T Ishii M Emi M Kurogi S Funamoto T Yonezawa Y Tajima T Sakamoto T Hamada H Chosa E

Objectives. We have previously investigated an association between the genome copy number variation (CNV) and acetabular dysplasia (AD). Hip osteoarthritis is associated with a genetic polymorphism in the aspartic acid repeat in the N-terminal region of the asporin (ASPN) gene; therefore, the present study aimed to investigate whether the CNV of ASPN is involved in the pathogenesis of AD. Methods. Acetabular coverage of all subjects was evaluated using radiological findings (Sharp angle, centre-edge (CE) angle, acetabular roof obliquity (ARO) angle, and minimum joint space width). Genomic DNA was extracted from peripheral blood leukocytes. Agilent’s region-targeted high-density oligonucleotide tiling microarray was used to analyse 64 female AD patients and 32 female control subjects. All statistical analyses were performed using EZR software (Fisher’s exact probability test, Pearson’s correlation test, and Student’s t-test). Results. CNV analysis of the ASPN gene revealed a copy number loss in significantly more AD patients (9/64) than control subjects (0/32; p = 0.0212). This loss occurred within a 60 kb region on 9q22.31, which harbours the gene for ASPN. The mean radiological parameters of these AD patients were significantly worse than those of the other subjects (Sharp angle, p = 0.0056; CE angle, p = 0.0076; ARO angle, p = 0.0065), and all nine patients required operative therapy such as total hip arthroplasty or pelvic osteotomy. Moreover, six of these nine patients had a history of operative or conservative therapy for developmental dysplasia of the hip. Conclusions. Copy number loss within the region harbouring the ASPN gene on 9q22.31 is associated with severe AD. A copy number loss in the ASPN gene region may play a role in the aetiology of severe AD. Cite this article: T. Sekimoto, M. Ishii, M. Emi, S. Kurogi, T. Funamoto, Y. Yonezawa, T. Tajima, T. Sakamoto, H. Hamada, E. Chosa. Copy number loss in the region of the ASPN gene in patients with acetabular dysplasia: ASPN CNV in acetabular dysplasia. Bone Joint Res 2017;6:439–445. DOI: 10.1302/2046-3758.67.BJR-2016-0094.R1


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 117 - 117
1 Nov 2018
Catelli D Ng K Kowalski E Beaulé P Lamontagne M
Full Access

Cam-type femoroacetabular impingement (FAI) is a common cause for athletic hip injury and early hip osteoarthritis. Although corrective cam FAI surgery can improve patient reported outcome measures (PROMs), it is not clear how surgery affects muscle forces and hip joint loading. Surgery for FAI may redistribute muscle forces and contact forces at the hip joint during routine activities. The purpose of this study was to examine the muscle contributions and hip contact forces during gait in patients prior and after two years of undergoing surgery for cam FAI. Kinematics and kinetics were recorded in 11 patients with symptomatic cam FAI as they completed a gait task. Muscle and hip contact forces during the stance phase were estimated using musculoskeletal modelling and static optimization in OpenSim. All patients reported improvements in PROMs. Post-operatively, patients showed reduced forces in the long head of the biceps femoris at ipsilateral foot-strike and in the rectus femoris at the contralateral foot-strike. The reduced muscle forces decreased sagittal hip moment but did not change hip contact forces. This was the first study to evaluate hip muscle and contact forces in FAI patients post-operatively. Although hip contact forces are not altered following surgery, muscle forces are decreased even after two years. These findings can provide guidance in optimizing recovery protocols after FAI surgery to improve hip flexor and extensor muscle forces


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 33 - 33
1 Oct 2016
Roberts S Salter D Ralston S
Full Access

TRIM32 is a candidate gene at the 9q33.1 genetic susceptibility locus for hip osteoarthritis (OA). Increased cartilage degradation typical of OA has previously been demonstrated in Trim32 knockout mice. Our aim is to investigate the role of TRIM32 in human and murine articular tissue. TRIM32 expression in human articular cartilage was examined by immunostaining. TRIM32 expression was compared in femoral head chondrocytes from patients with and without primary hip OA (n=6/group) and examined by Western blotting. Aggrecanolysis by femoral head explants from Trim32 knockout (T32KO) and wild-type (WT) mice was compared following stimulation with IL1α or retinoic acid (RA) and was assessed by DMMB assay (n=4/group). Expression of chondrocyte phenotype markers was measured by qPCR and compared between articular chondrocytes from WT and T32KO mice following catabolic (IL1α/TNFα) or anabolic (Oncostatin-M (OSM)/IGF1) stimulation. TRIM32 expression was demonstrated in human articular cartilage; TRIM32 expression by chondrocytes was reduced in patients with hip OA (p=0.03). Greater aggrecanolysis occurred in cartilage explants from T32KO mice after treatment with no stimulation (p=0.03), IL1α (p=0.02), and RA (p=0.001). Unstimulated T32KO chondrocytes expressed reduced Col2a1 (p=8.53×10. −5. ), and Sox9 (p=2.35×10. −6. ). Upon IL1α treatment, T32KO chondrocytes expressed increased Col10a1 (p=0.0003). Upon anabolic stimulation, T32KO chondrocytes expressed increased Col2a1 (OSM: p=0.001; IGF: p=0.001), and reduced Sox9 (OSM: p=0.0002; IGF: p=0.0006). These results indicate that altered TRIM32 expression in human articular tissue is associated with OA, and that Trim32 knockout results in increased cartilage degradation in murine femoral head explants. Predisposition to cartilage degeneration with reduced Trim32 expression may involve increased chondrocyte hypertrophy upon catabolic cytokine stimulation and dysregulation of Col2a1 and Sox9 expression upon anabolic stimulation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 58 - 58
1 Mar 2013
Duffell LD Gulati V Southgate DF McGregor AH
Full Access

People with severe degenerative conditions, such as osteoarthritis (OA), have been shown to have altered movement patterns during sit-to-stand. However it remains unclear whether such alterations exist in people with early OA, in the absence of pain. This study aimed to determine if a novel seat could be used to discriminate people with early OA compared with controls. The sit-to-stand task was performed by 20 people with early medial knee OA and 20 age and gender-matched control subjects, using an instrumented seat. OA subjects showed altered weight distribution in the transition phase from sit to stand, in that they placed more load through their unaffected side. Task duration was also significantly longer for OA subjects. This study has demonstrated that a novel instrumented seat can be used to discriminate people with early medial knee OA during the sit-to-stand activity. These results may be relevant for early interventions to delay or prevent changes in muscle function of the affected limb as well as contralateral knee or hip osteoarthritis in these patients


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 29 - 29
1 Mar 2013
Okoro T Stewart C Al-Shanti N Lemmey A Maddison P Andrew J
Full Access

Aim. To assess the relationship between mRNA expression of genetic markers of inflammation (tumour necrosis factor-alpha (TNFα)) and interleukin-6 (IL-6) in the vastus lateralis (VL) of the operated leg, and the strength of the operated leg quadriceps, in patients following THR. Methods. Following ethical approval, 10 patients were recruited prospectively. Distal VL (5cm proximal to lateral supra-patellar pouch) biopsies were obtained intraoperatively and at 6 weeks post-operatively, with maximal voluntary contraction of the operated leg quadriceps (MVCOLQ) in Newtons(N), assessed preoperatively and at 6 weeks post-op. mRNA expression in the biopsies was assessed using the reverse transcriptase polymerase chain reaction (RT-PCR). Relationships were assessed using Spearman's correlation coefficient (data not normally distributed). Results. mRNA RQ (comparison of 6 week VL samples to intraoperative samples) was (mean (SD)) 6.23(12.85) for TNFα and 17.10(47.46) for IL-6. Preoperatively mean MVCOLQ was 188.90(76.84) N and at 6 weeks it was 217.00(53.91) N. There was no significant relationship between TNFα or IL-6 RQ and absolute MVCOLQ at 6 weeks. A trend to significance was noted between TNFα and the improvement (%) in MVCOLQ at 6 weeks (R = −0.552, p=0.098) with no such relationship observed for IL-6 (R = 0.127, p=0.726). Conclusions. In patients with hip osteoarthritis, reduced strength (MVCOLQ) appears to be mediated by muscle inflammation. The trend to correlation that exists for improvement in MVCOLQ with TNFα indicates that muscle inflammation may be one of the causes of pain in patients with severe osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 44 - 44
1 Jun 2012
Smith J Hussain S Horey L Patil S Meek R
Full Access

Hip resurfacing has generally been used in younger patients with early osteoarthritis of the hip. There has been considerable recent interest in this over the past few years. We conducted a prospective randomised trial comparing 2 hip resurfacing implants, Durom and ASR looking at radiological and clinical outcomes. Forty-nine patients (78% male) with hip osteoarthritis which met the criteria for hip resurfacing were randomised to receive either a Durom or ASR resurfacing implant. These patients have so far been followed up for a minimum of one year. The groups were comparable in age (p=0.124) and gender (p=0.675). The average age in the ASR group was 54.04 years and in the Durom group it was 51.25. Radiological views were scrutinised immediately post op and at final follow up so far to look at cup inclination, stem-shaft angle, and acetabular osseointegration. Clinical outcomes were compared using the Oxford hip scores, WOMAC scores and SF12 scores. At minimum follow up of 1 year the mean post operative Oxford hip score was not significantly different between the Durom (45.32, SD 3.93) and ASR (43.44, SD 8.44). The mean post operative WOMAC score was also not significantly different between the Durom (52.56, SD 6.06) and ASR (49.63, SD 2.23). There was no difference between the groups with regards to signs of osseointegration from radiological assessment (p=0.368). There were 3 periprosthetic femoral neck fractures (5.7%) and one revision for pain. We conclude from this trial that there is no difference in the clinical or radiological findings between the Durom and ASR implants


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 71 - 71
1 Aug 2012
Thiagarajah S MacInnes S Yang L Wilkinson J
Full Access

Introduction. Subtle variations in hip morphology associate with risk of hip osteoarthritis (OA). However, validated accurate methods to quantitate hip morphology using plain radiography are lacking. We have developed a Matlab-based software-tool (SHIPs) that measures 19 OA-associated morphological-parameters of the hip using a PACS pelvic radiograph. In this study we evaluated the accuracy and repeatability of the method. Methods. Software accuracy was assessed by firstly measuring the linear ratio of 2 fixed distances and several angles against a gold-standard test radiograph, and secondly by repeated measurements on a simulated AP radiograph of the pelvis (reformatted from CT-data) that was digitally rotated about 3-axes to determine the error associated with pelvic mal-positioning. Repeatability was assessed using 30-AP Pelvic radiographs analysed twice (intra-observer), by 2 readers (inter-observer), and finally, using 2 pelvic radiographs taken in 23 subjects (n=46 radiographs) taken same day after re-positioning (short-term clinical-practice variability), and was expressed as coefficient of variation (CV%). Results. Software accuracy was 0.1% for linear measurements, and 0.2, 0.4, and 0.1 degrees, for angular measurements of 30, 60, and 90 degrees, respectively. Anterior rotation of the pelvis in the sagittal plane beyond 10 degrees produced a decrease in acetabular-tilt (-11 degrees at 20 degrees rotation) and acetabular-index-of-depth-to-width-ratio (-9.3% at 20 degrees rotation). Conversely, femoral-head-to-neck-ratio increased with both anterior and transverse rotation (+9% to +14% at 20 degrees rotation). The intra-observer CV was between 0.3-6.3%, and inter-observer CV was between 0.7-14.9% for all measurements with the exception of the measurement of horizontal-toit-externa (HTE) that had intra and inter-observer CVs of 33.4 and 29.1%, respectively. Short-term clinical repeatability was between 0.4-8.5%, with the exception of HTE that was 20.7%). Discussion. This software showed good accuracy and precision for the measurement of OA-associated hip morphological-parameters from plain radiographs of the pelvis, and may be useful in clinical research studies quantitating the relationship of these parameters to the development of hip OA. The method is, however, sensitive to large variations in pelvic positioning and use of the HTE measurement is associated with poor repeatability that is likely due to poor definition of the bony landmarks used for this parameter


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 47 - 47
1 Jul 2014
Trisolino G Strazzari A Stagni C Tedesco G Albisinni U Martucci E Dallari D
Full Access

Summary Statement. Pincer deformities are involved in the genesis of femoro-acetabular impingement (FAI). Radiographic patterns suggestive of pincer deformities are common among general population. Prevalence of the pincer deformities among general population may be overestimated if only plain radiographs are considered. Background. Pincer deformities (coxa profunda, protrusio acetabuli, global retroversion, isolated cranial over-coverage) have been advocated as a cause of femoro-acetabular impingement (FAI) and early hip osteoarthritis (OA). Different radiographic patterns may advocate the presence of a pincer deformity. The prevalence of these radiographic patterns among general adult population, as their role in early hip OA, is poorly defined. Methods. From a database of 40.351 pelvic radiograms and CT collected at our institution between 2005 and 2010, we selected 118 caucasian individuals (56 females, 62 males), aged between 15 and 60 years, who underwent both plain radiographs and CT of the pelvis. A series of exclusion criteria were strictly applied to achieve a sample of adult general population as more representative as possible. In particular patients with presence of any disease involving hip joint, including: advanced hip OA (grade II or III of Tonnis scale), head necrosis, fractures, heterotopic ossifications, bone and soft tissue tumors, rheumatic pathologies, classic hip dysplasia with lateral center-edge angle (L-CEA) less than 20°, clinical diagnosis of FAI or hip pain, were excluded from the present study. We also excluded patients in which open growth plates, osteopenia, hardware or evidence of prior surgery were present. Radiographs were investigated for pelvic tilt, signs of retroversion, lateral center-edge angle (L-CEA), presence of coxa profunda or protrusio acetabuli. EAV was measured on CT scans at the equatorial plane of the acetabulum passing by the 3 o'clock position, while CAV was calculated at a more cranial level corresponding to the 1 o'clock position EAV and CAV were obtained in the axial plane by measuring the angle made by a line connecting the anterior and posterior rims of the acetabulum and a line perpendicular to the line connecting the ischial spines. A new parameter, Acetabular torsion (AT), has been introduced in order to discriminate between global retroversion and isolated cranial over-coverage. AT was defined as the difference between EAV and CAV. Cam deformity was assessed by calculating the alpha angle on the femoral side; an alpha angle > 55° was considered abnormal and suggestive of cam deformity. Radiological signs of chondrolabral degeneration were noticed. Results. Mean EAV and mean CAV were higher in females, mean AA was higher in males. L-CEA, EAV and CAV increased with age. Mean AT was 8.8±6.3. AT was inversely related to CAV (r=−0.799; p<0.0005) but independent from EAV (r=−0.076; p=0.244). EAV≤10.2° was defined as the marker of global retroversion, while AT≥21.2° was defined as the marker of isolated cranial over-coverage. Overall prevalence of pincer deformities was 21.6% (> females; p=0.02). Early OA changes were related to age (p<0.0005) and AA (p<0.0005), but not to pincer deformities (p=0.96). Radiological signs of retroversion showed good or excellent negative predictability but poor positive predictability. Conclusions. Radiographic patterns of pincer deformities are common among general population. Relationship with radiological signs of chondrolabral degeneration is poor. CT allows to discriminate between global retroversion and isolated cranial over-coverage. Prevalence of the pincer deformities among general population may be overestimated if only plain radiographs are considered