Long femoral nails for neck of femur fractures and prophylactic fixation have a risk of anterior cortex perforation. Previous studies have demonstrated the radius of curvature (ROC) of a femoral nail influencing the finishing point of a nail and the risk of anterior cortex perforation. This study aims to calculate a patients femoral ROC using preoperative XR and CT and therefore nail finishing position. We conducted a retrospective study review of patients with long femoral cephalomedullary nailing for proximal femur fractures (OTA/AO 31(A) and OTA/AO 32) or impending pathological fractures at a level 1 trauma centre between January 1, 2015 and December 31, 2020 with both full length lateral X-ray and CT imaging. Femoral ROC was calculated on both imaging modalities. Outcomes measured including nail finishing position, anterior cortex encroachment and impingement. The mean femoral ROC was 1026mm on CT and 1244mm on XR. CT femoral ROC strongly correlated with nail finishing point with a spearmans coefficient of 0.77. Additionally, femurs with a ROC <1000mm were associated with a higher risk of anterior encroachment (OR 6.12) and femurs with a ROC <900mm were associated with a higher risk of anterior cortex impingement (OR 6.47). To our knowledge this is the first study to compare a measured femoral ROC to nail finishing position. The use of CT to measure femoral ROC and to a lesser extent XR was able to predict both nail finishing position and risk of anterior cortex encroachment. Preoperative XRs and CTs were able to identify patients with a small femoral ROC. This predicted patients at risk of anterior cortex impingement, anterior cortex encroachment and nail finishing position. We may be able to select femoral nails that resemble the native femoral ROC and mitigate the risk of anterior cortex perforation


Proximal femoral focal deficiency is a congenital disorder of malformation of the proximal femur and/or the acetabulum. Patients present with limb length discrepancy and clinical features along a spectrum of severity. As these patients progress through to skeletal maturity and on to adulthood, altered biomechanical demands lead to progression of arthropathy in any joint within the lower limb. Abnormal anatomy presents a challenge to surgeons and conventional approaches and implants may not necessarily be applicable. We present a case of a 62-year-old lady with unilateral proximal femoral focal deficiency (suspected Aitken Class A) who ambulated with an equinus prosthesis for her entire life. She presented with ipsilateral knee pain and instability due to knee arthritis but could not tolerate a total knee arthroplasty due to poor quadriceps control. A custom osteointegration prosthesis was inserted with a view to converting to the proximal segment to a total hip replacement if required. The patient went on to develop ipsilateral symptomatic hip arthritis but altered acetabular anatomy required a custom tri-flange component (Ossis, Christchurch, New Zealand) and a custom proximal femoral component to link with the existing osseointegration component (Osseointegration Group of Australia, Sydney, Australia) were designed and implanted. The 18 month follow up of the custom hip components showed that the patient had Oxford hip scores that were markedly improved from pre-operatively. Knee joint heights were successfully restored to equal when the patient's prosthesis was attached. The patient describes feeling like “a normal person”, walks unaided for short distances and can ambulate longer distances with crutches. Advances in design and manufacture of implants have empowered surgeons to offer life improving treatments to patients with challenging anatomy. Using a custom acetabular tri-flange and osseointegration components is one possible solution to address symptomatic ipsilateral hip and knee arthropathy in the context of PFFD in adulthood


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 16 - 16
10 Feb 2023
Gibson A Guest M Taylor T Gwynne Jones D
Full Access

The purpose of this study was to determine whether there have been changes in the complexity of femoral fragility fractures presenting to our Dunedin Orthopaedic Department, New Zealand, over a period of ten years. Patients over the age of 60 presenting with femoral fragility fractures to Dunedin Hospital in 2009 −10 (335 fractures) were compared with respect to demographic data, incidence rates, fracture classification and treatment details to the period 2018-19 (311 fractures). Pathological and high velocity fractures were excluded. The gender proportion and average age (83.1 vs 83.0 years) was unchanged. The overall incidence of femoral fractures in people over 60 years in our region fell by 27% (p<0.001). Intracapsular fractures (31 B1 and B2) fell by 29% (p=0.03) and stable trochanteric fractures by 56% (p<0.001). The incidence of unstable trochanteric fractures (31A2 and 31A3) increased by 84.5% from 3.5 to 6.4/10,000 over 60 years (p = 0.04). The proportion of trochanteric fractures treated with an intramedullary (IM) nail increased from 8% to 37% (p <0.001). Fewer intracapsular fractures were treated by internal fixation (p<0.001) and the rate of acute total hip joint replacements increased from 13 to 21% (p=0.07). The incidence of femoral shaft fractures did not change significantly with periprosthetic fractures comprising 70% in both cohorts. While there has been little difference in the numbers there has been a decrease in the incidence of femoral fragility fractures likely due to the increasing use of bisphosphonates. However, the incidence of unstable trochanteric fractures is increasing. This has led to the increased use of IM nails which are increasingly used for stable fractures as well. The increasing complexity of femoral fragility fractures is likely to have an impact on implant use, theatre time and cost


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 57 - 57
1 Dec 2022
Gazendam A Ekhtiari S Wood T Petruccelli D Tushinski D Winemaker MJ de Beer J
Full Access

The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the long-term survival of this stem and analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. A retrospective review was undertaken of all patients who received a primary total hip arthroplasty with an Accolade® TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to minimize loss to follow-up. Survivorship analysis was performed with use of the Kaplan-Meier curves to determine the overall and aseptic survival rates at final follow-up. Patient and implant factors commonly associated with aseptic failure were extracted and Cox proportional hazards model was used. A consecutive series of 2609 unilateral primary THA patients implanted with an Accolade®TMZF femoral hip stem were included. Mean time from primary surgery was 12.4 years (range 22 days to 19.5 years). Cumulative survival was 96.1% ± 0.2 at final follow-up. One hundred and seven patients underwent revision surgery with aseptic loosening of the femoral component was the most common cause of aseptic failure in this cohort (33/2609, 1.3%). Younger age and larger femoral head offset were independent risk factors for aseptic failure. To our knowledge, this is the largest series representing the longest follow-up of this taper-wedge cementless femoral implant. Despite early concerns, the Accolade® TMZF stem has excellent survivorship in this cohort. Trunnionosis as a recognized cause for revision surgery was rare. Younger age and larger femoral head offset were independent risk factors for aseptic failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 45 - 45
1 Jun 2023
Robinson M Mackey R Duffy C Ballard J
Full Access

Introduction. Osteogenesis imperfect (OI) is a geno- and phenotypically heterogeneous group of congenital collagen disorders characterized by fragility and microfractures resulting in long bone deformities. OI can lead to progressive femoral coxa vara from bone and muscular imbalance and continuous microfracture about the proximal femur. If left untreated, patients develop Trendelenburg gait, leg length discrepancy, further stress fracture and acute fracture at the apex of the deformity, impingement and hip joint degeneration. In the OI patient, femoral coxa vara cannot be treated in isolation and consideration must be given to protecting the whole bone with the primary goal of verticalization and improved biomechanical stability to allow early loading, safe standing, re-orientation of the physis and avoidance of untreated sequelae. Implant constructs should therefore be designed to accommodate and protect the whole bone. The normal paediatric femoral neck shaft angle (FNSA) ranges from 135 to 145 degrees. In OI the progressive pathomechanical changes result in FNSA of significantly less than 120 degrees and decreased Hilgenreiner epiphyseal angles (HEA). Proximal femoral valgus osteotomy is considered the standard surgical treatment for coxa vara and multiple surgical techniques have been described, each with their associated complications. In this paper we present the novel technique of controlling femoral version and coronal alignment using a tubular plate and long bone protection with the use of teleoscoping rods. Methodology. After the decision to operate had been made, a CT scan of the femur was performed. A 1:1 scale 3D printed model (AXIAL3D, Belfast, UK) was made from the CT scan to allow for accurate implant templating and osteotomy planning. In all cases a subtrochanteric osteotomy was performed and fixed using a pre-bent 3.5 mm 1/3 tubular plate. The plate was bent to allow one end to be inserted into the proximal femur to act as a blade. A channel into the femoral neck was opened using a flat osteotome. The plate was then tapped into the femoral neck to the predetermined position. The final position needed to allow one of the plate holes to accommodate the growing rod. This had to be determined pre operatively using the 3D printed model and the implants. The femoral canal was reamed, and the growing rod was placed in the femur, passing through the hole in the plate to create a construct that could effectively protect both the femoral neck and the full length of the shaft. The distal part of the plate was then fixed to the shaft using eccentric screws around the nail to complete the construct. Results. Three children ages 5,8 and 13 underwent the procedure. Five coxa vara femurs have undergone this technique with follow-up out to 62 months (41–85 months) from surgery. Improvements in the femoral neck shaft angle (FNSA) were av. 18. o. (10–38. o. ) with pre-op coxa vara FNSA av. 99. o. (range 87–114. o. ) and final FNSA 117. o. (105–125. o. ). Hilgenreiner's epiphyseal angle was improved by av. 29. o. (2–58. o. ). However only one hip was restored to <25. o. In the initial technique employed for 3 hips, the plates were left short in the neck to avoid damaging the physis. This resulted in 2 of 3 hips fracturing through the femoral neck above the plate at approximately 1 year. There were revisions of the 3 hips to longer plates to prevent intra-capsular stress riser. All osteotomies united and both intracapsular fractures healed. No further fractures have occurred within the protected femurs and no other repeat operations have been required. Conclusions. Surgical correction of the OI coxa vara hip is complex. Bone mineral density, multiplanar deformity, a desire to maintain physeal growth and protection of the whole bone all play a role in the surgeon's decision making process. Following modifications, this technique demonstrates a novel method in planning and control of multiplanar proximal femoral deformity, resulting in restoration of the FNSA to a more appropriate anatomical alignment, preventing long bone fracture and improved femoral verticalization in the medium term follow-up


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 22 - 22
23 Apr 2024
Laufer A Frommer A Gosheger G Toporowski G Rölfing JD Antfang C Roedl R Vogt B
Full Access

Introduction. Coronal malalignment and leg length discrepancies (LLD) are frequently associated. Temporary hemiepiphysiodesis (tHED) is commonly employed for the correction of limb malalignment in skeletally immature patients. For treatment of LLD greater than 2 cm, lengthening with intramedullary legnthening nails is a safe and reliable technique. However, the combined application of these approaches in skeletally immature patients has not yet been investigated. Materials & Methods. Retrospective radiological and clinical analysis of 25 patients (14 females, 11 males) who underwent intramedullary femoral lengthening with an antegrade PRECICE® lengthening nail as well as tHED of the distal femur and / or proximal tibia between 2014 and 2019. tHED was conducted by implantation of flexible staples (FlexTack™) either prior (n = 11), simultaneously (n = 10), or subsequently (n = 4) to femoral lengthening. The mean follow-up period was 3.7 years (±1.4). Results. The median initial LLD was 39.0 mm (35.0–45.0). 21 patients (84%) presented valgus and 4 (16%) showed varus malalignment. Leg length equalization was achieved in 13 patients at skeletal maturity (62%). The median LLD of patients with a residual LLD > 10 mm was 15.5 mm (12.8–21.8). Limb realignment was obtained in nine of seventeen skeletally mature patients (53%) in the valgus group, and in one of four patients (25%) in the varus group. Conclusions. The combination of antegrade femoral lengthening and tHED can efficiently correct LLD and coronal limb malalignment in skeletally immature patients. Nevertheless, achieving limb length equalization and realignment may render difficult in cases of severe LLD and angular deformity. Furthermore, the reported techniques ought to be thoroughly planned and executed and require regular clinical and radiological examinations until skeletal maturity to avoid - or timely detect and manage - adverse events such as overcorrection and rebound of deformity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 9 - 9
23 Apr 2024
Ramlawi AA McClure P Assayag M
Full Access

Introduction. The practice of limb lengthening using intramedullary nails has surged in popularity in recent years. Our study explores the relationship between femur lengthening and overall height gain in adults undergoing cosmetic limb lengthening with telescoping magnetic intramedullary lengthening nails (MILNs). Materials & Methods. Demographic information, pre- and postoperative radiographic data, and secondary outcomes, such as mechanical angles and sagittal alignment, were analyzed for 42 adult femurs MILNs (PRECICE 2, NuVasive, Inc.). Height was assessed with a digital stadiometer. Limb lengthening was defined as the amount of nail distraction seen on a calibrated weight bearing X-ray at consolidation. mLDFA, mMPTA, MAD, AMA, and femoral sagittal bow were evaluated as secondary outcomes. Results. Mean starting height was 163.5 cm (SD 10.4, range 137–179) Post -lengthening mean height increased to 171.1 cm (SD 10.1, range 146.7–185.3). Average height gain was 7.5 cm (SD 1.3 cm, range 5.1–9.5). Average femoral lengthening was 7.3 cm (SD 1.14, range 4.1–10.1). There were no statistically significant difference between height gain and femur lengthening. Secondary outcomes showed reductions in femoral sagittal bow and AMA. Conclusions. We conclude that measuring femur lengthening is a reliable and accurate method of measuring gained height in deformity-free patients undergoing limb lengthening. We further reason that straightening of both femoral and spinal sagittal bow counteracts potential lengthening loss over the anatomical axis, versus mechanical axis lengthening


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 15 - 15
1 Oct 2022
Loro A
Full Access

Aim. In recent years, the number of victims of road traffic accidents (RTAs) and resulting surgeries have been on the rise in low income countries. Treatments are often long and costly; resources required to treat fracture related infections (FRI) continue to be a limiting factor in low income countries and standardized management protocols are lacking. This retrospective study reports our facility's experience of femoral FRI management in a low income country and evaluates the surgical outcomes with a minimum follow up of five years. Methods. The clinical and radiographic records of patients who underwent surgery for femoral FRI in our facility between 2005–2016 were analyzed. Twenty-six patients were included (15 males), with a median age of 29 years (range 4–71). The initial fracture was caused by RTA in 22 patients, gunshot in 2, accidental fall in 1 and acute osteomyelitis in 1. Polytrauma was observed in 10. All patients but one were referred for limb reconstruction from other institutions. Surgical treatment was instituted in all: site debridement (SD) alone was performed in 2 patients; SD and hardware removal in 4; SD and external fixation in 4; SD, hardware removal and external fixation in 16. In this latter group, complex treatments such as bone transport (BT) and vascularized fibula flap (VFF) were utilized in 4 and 3 patients respectively. Results. The mean follow-up was 8.4 years. Bone union was achieved in all cases with eradication of the infection in all but one. A total of 109 surgeries were carried out with an average of 4 surgeries per patient (range 1–13). The external fixation stayed in place for an average of 9.2 months (range 3–20). Complications were common at the last follow-up: limb length discrepancy (LLD) was observed in 18 patients; stiff knee was noted in 16; stiffness of ipsilateral knee and hip in 3; stiff hip in 1 and fused knee in 3. All patients ambulated without assistive devices. Conclusions. The treatment of femoral FRI is complex, long and often requires the combined effort of the orthopedic and plastic surgical teams. Despite limited resources, our institution achieved good long term surgical outcomes through a variety of methods. Further studies are required across multiple sites to better outline optimal management of femoral FRI in low income countries


Increasing expectations from arthroscopic anterior cruciate ligament (ACL) reconstructions require precise knowledge of technical details such as minimum intra-femoral tunnel graft lengths. A common belief of having ≥20mm of grafts within the femoral tunnel is backed mostly by hearsay rather than scientific proof. We examined clinico-radiological outcomes in patients with intra-femoral tunnel graft lengths <20 and ≥20mm. Primary outcomes were knee scores at 1-year. Secondarily, graft revascularization was compared using magnetic resonance imaging (MRI). We hypothesized that outcomes would be independent of intra-femoral tunnel graft lengths. This prospective, single-surgeon, cohort study was conducted at a tertiary care teaching centre between 2015–2018 after obtaining ethical clearances and consents. Eligible arthroscopic ACL reconstruction patients were sequentially divided into 2 groups based on the intra-femoral tunnel graft lengths (A: < 20 mm, n = 27; and B: ≥ 20 mm, n = 25). Exclusions were made for those > 45 years of age, with chondral and/or multi-ligamentous injuries and with systemic pathologies. All patients were postoperatively examined and scored (Lysholm and modified Cincinnati scores) at 3, 6 and 12 months. Graft vascularity was assessed by signal-to-noise quotient ratio (SNQR) using MRI. Statistical significance was set at p<0.05. Age and sex-matched patients of both groups were followed to 1 year (1 dropout in each). Mean femoral and tibial tunnel diameters (P =0.225 and 0.595) were comparable. Groups A (<20mm) and B (≥20mm) had 27 and 25 patients respectively. At 3 months, 2 group A patients and 1 group B patient had grade 1 Lachman (increased at 12 months to 4 and 3 patients respectively). Pivot shift was negative in all patients. Lysholm scores at 3 and 6 months were comparable (P3= 0.195 and P6= 0.133). At 1 year both groups showed comparable Cincinnati scores. Mean ROM was satisfactory (≥130 degrees) in all but 2 patients of each group (125–130 degrees). MRI scans at 3 months and 1 year observed anatomical tunnels in all without any complications. Femoral tunnel signals in both groups showed a fall from 3–12 months indicating onset of maturation of graft at femoral tunnel. Our hypothesis, clinical and radiological outcomes would be independent of intra-tunnel graft lengths on the femoral aspect, did therefore prove correct. Intra-femoral tunnel graft lengths of <20 mm did not compromise early clinical and functional outcomes of ACL reconstructions. There seems to be no minimum length of graft within the tunnel below which suboptimal results should be expected


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 62 - 62
22 Nov 2024
Mueller MM Kowald B Gerlach U Grimme C Schulz A Frosch K Schoop-Schmetgens R
Full Access

Aim. Aim of this study was to establish the first clinical results after implantation of ultrathin silver-polysiloxane-coated. 1. plates in the treatment of infected non-union of the femoral shaft. Method. As part of the REFECT study, a prospective, non-interventional analysis was conducted encompassing all patients who received internal stabilization with a silver-coated. 1. plate from 01/2023 to 09/2024 as part of the treatment for infected non-union of the femur. Standardized clinical follow-ups including PROMs (WOMAC-Index, LEF-S, EQ-5D, VAS) and X-rays were performed 3, 6, 12 (and 24) months postoperatively. For comparison, a retrospective analysis of 76 patients with infected femoral non-union, who had received a stabilization with an uncoated plate in the past 10 years, was performed. Results. The mean follow-up of the 8 included patients (mean bone defect: 3.6 cm) was 9 months (as of 04/24). Multiresistant bacteria were found in the intraoperative samples of 5 patients. The concentration of silver ions in blood serum reached a maximum of 0.014 mg/l in the laboratory controls. All patients showed a positive healing process with no sign of re-infection and no adverse procedure-associated events. Full weight bearing was achieved after an average of 4 months (n=6) with improved WOMAC-, LEF-S-, EQ-5D and VAS-score at 1-year FU. In the reference group (uncoated, mean FU: 3.5 years), there was a re-infection rate of 25 %, mostly in the first 2 years. Difficult-to-treat bacteria were detected in 22%, multiresistant Staph. epidermidis in 28% of cases. Conclusions. -. The silver-coated. 1. implants showed good biocompatibility with no evidence of procedure-associated complications. -. The use of silver-coated. 1. implants could reduce the risk of re-infection. -. Further clinical data with longer follow-up are needed to assess the long-term value of the procedure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 32 - 32
1 Apr 2022
French J Filer J Hogan K Fletcher J Mitchell S
Full Access

Introduction. Computer hexapod assisted orthopaedic surgery (CHAOS) has previously been shown to provide a predictable and safe method for correcting multiplanar femoral deformity. We report the outcomes of tibial deformity correction using CHAOS, as well as a new cohort of femoral CHAOS procedures. Materials and Methods. Retrospective review of medical records and radiographs for patients who underwent CHAOS for lower limb deformity at our tertiary centre between 2012–2020. Results. There were 70 consecutive cases from 56 patients with no loss to follow-up. Mean age was 40 years (17 to 77); 59% male. There were 48 femoral and 22 tibial procedures. Method of fixation was intramedullary nailing in 47 cases and locking plates in 23. Multiplanar correction was required in 43 cases. The largest correction of rotation was 40 degrees, and angulation was 28 degrees. Mean mechanical axis deviation reduction per procedure was 17.2 mm, maximum 89 mm. Deformity correction was mechanically satisfactory in all patients bar one who was under-corrected, requiring revision. Complications from femoral surgery included one under-correction, two cases of non-union, and one pulmonary embolism. Complications from tibial surgery were one locking plate fatigue failure, one compartment syndrome, one pseudoaneurysm of the anterior tibial artery requiring stenting, and one transient neurapraxia of the common peroneal nerve. There were no deaths. Conclusions. CHAOS can be used for reliable correction of complex deformities of both the femur and tibia. The risk profile appears to differ between femoral and tibial surgeries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 59 - 59
10 Feb 2023
Hancock D Morley D Wyatt M Roberts P Zhang J van Dalen J
Full Access

When removing femoral cement in revision hip surgery, creating an anterior femoral cortical window is an attractive alternative to extended trochanteric osteotomy. We describe our experience and evolution of this technique, the clinical and radiological results, and functional outcomes. Between 2006 and 2021 we used this technique in 22 consecutive cases at Whanganui Hospital, New Zealand. The average age at surgery was 74 years (Range 44 to 89 years). 16 cases were for aseptic loosening: six cases for infection. The technique has evolved to be more precise and since 2019 the combination of CT imaging and 3-D printing technology has allowed patient-specific (PSI) jigs to be created (6 cases). This technique now facilitates cement removal by potentiating exposure through an optimally sized anterior femoral window. Bone incorporation of the cortical window and functional outcomes were assessed in 22 cases, using computer tomography and Oxford scores respectively at six months post revision surgery. Of the septic cases, five went onto successful stage two procedures, the other to a Girdlestone procedure. On average, 80% bony incorporation of the cortical window occurred (range 40 −100%). The average Oxford hip score was 37 (range 22 – 48). Functional outcome (Oxford Hip) scores were available in 11 cases (9 pre-PSI jig and 2 using PSI jig). There were two cases with femoral component subsidence (1 using the PSI jig). This case series has shown the effectiveness of removing a distal femoral cement mantle using an anterior femoral cortical window, now optimized by using a patient specific jig with subsequent reliable bony integration, and functional outcomes comparable with the mean score for revision hip procedures reported in the New Zealand Joint Registry


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems. There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001). There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size. High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 83 - 83
1 May 2016
Chun Y Rhyu K Baek J Oh K Lee J Cho Y
Full Access

Purpose. The purpose of this study was to evaluate and compare the clinical, radiological outcomes of the group of patients with distal femoral cortical hypertrophy (DFCH) and without DFCH after hip arthroplasty using a cementless double tapered femoral stem and to analyze a correlation between patients factors and DFCH. Materials and Methods. Four hundreds four patients (437 hips) who underwent total hip arthroplasty (n = 293) or hemiarthroplasty (n = 144) using a Accolade TMZF femoral stem between Jun 2006 and March 2012 and were follow up period more than 24 months after surgery were enrolled in this study. They were divided into 2 groups, the one group (n = 27) included patients with DFCH, and the other group (n = 410) included patients without DFCH. The mean follow up period was 54.5 months (range, 24 to 85 months) and 56.2 months (range, 24 to 92 months) for patients with DFCH and without DFCH. Results. The mean HHS, VAS signiï¬cantly improved from 61.4 and 5.5 preoperatively to 95.9 and 1.0 at the ï¬nal follow-up, respectively (P< .001), in the DFCH group and from 57.8 and 4.5 to 91.6 and 0.6 respectively (P< .001), in the control group. There were no signiï¬cant differences between the 2 groups (P> .05). Incidence of the thigh pain in the DFCH group (18.5%) was significantly higher than the control group (2.2%) (P< .001). The mean canal flare index (CFI) and subsidence was 3.71 (range, 2.61 to 5.78) and 1.5 mm (range, 0.1 to 6.1mm) for the DFCH group, 3.30 (range, 1.31 to 5.61) and 3.4 mm (range, 0.33 to 14.9 mm) for the control group. There were significantly differences between 2 groups (p< .002, < .001). The DFCH was significantly correlated with thigh pain and subsidence (p= .001; OR, 11.194; CI, 3.434 to 36.498 for thigh pain, p= .001; OR, 0.080; CI, 0.032 to 0.198 for subsidence), but not with sex. The incidence of DFCH increased significantly with increasing CFI and decreasing age (P= .043; OR, 1.828; CI, 1.018 to 3.280 for CFI; P= .015; OR, 0.968; CI, 0.944 to 0.994 for age). All the femoral stems showed stable fixation and there was no osteolysis or loosening. Conclusion. The DFCH occurs in 6.2% after hip arthroplasties using a double tapered femoral stem. The DFCH group showed less incidence of vertical subsidence, more younger and larger CFI. Difficult over tight placement of femoral stem to the distal femur results on DFCH, as well as thigh pain in some cases. However, there was no influence on clinical outcomes and femoral stem instability, bony fixation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 97 - 97
10 Feb 2023
Gibbons J Bodian C Powell A Sharr J Lash N
Full Access

PFFs are an increasing burden presenting to the acute trauma services. The purpose of this study is to show that cemented revision for Vancouver B2/B3 PFFs is a safe option in the geriatric population, allows early pain-free weight bearing and comparable to a control-group of uncemented stems with regard to return to theatre and revision surgery. A retrospective review was conducted of all PFFs treated in a Level 1 trauma centre from 2015-2020. Follow up x-rays and clinical course through electronic chart was reviewed for 78 cemented revisions and 49 uncemented revisions for PFF. Primary endpoints were all cause revision and return to theatre for any reason. Secondary endpoints recorded mobility status and all-cause mortality. In the cemented group there were 73 Vancouver B2, 5 Vancouver B3 PFF; the mean age was 79.7 years and mean radiological follow-up of 11.9 months. In the cementless group there were 32 Vancouver B2 and 17 Vancouver B3 PFFs; with all 49 patients undergoing distally bearing uncemented revision, the mean age was 72.7 years and mean radiological follow-up of 21.3 months. Patients treated with a cemented prosthesis had significantly higher ASA score (2.94 -v- 2.43, p<0.001). The primary endpoints showed that there was no significant difference in all cause revision 3/78 and 5/49 p=0.077, or return to theatre 13/78 -v- 12/49 p=0.142. Secondary endpoints revealed no significant difference in in-hospital mortality. The cementless group were more likely to be mobilising without any aid at latest follow-up 35/49 -v- 24/78 p<0.001. The use of cemented revision femoral component in the setting of PFFs is one option in the algorithm for management of unstable PFFs according to the Vancouver classification. Evidence from this case-control study, shows that the all-cause revision and return to theatre for any cause was comparable in both groups


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 131 - 131
1 Dec 2013
Murphy J Courtney P Lee G
Full Access

Proper restoration of posterior condylar offset during TKA has been shown to be important to maximize range of motion and minimize flexion instability. However, there is little information as to the importance of restoration of mid-sagittal femoral geometry. There is controversy as to whether a TKA prosthesis should have a single radius or multiple radii of curvature. The purpose of this study is to evaluate the effectiveness of a multi-radius femoral component at restoring mid sagittal femoral offset. A consecutive series of 100 TKAs with digital preoperative and postoperative radiographs and standardized radiographic markers were analyzed. There were 71 female and 29 male knees with mean age of 59 years. All TKAs were performed by a single surgeon using a multi-radius femoral component design. The distal femoral resection was set to resect 10 mm from the distal femoral condyle and a posterior referencing system was used to size the femoral component. Using radiographic perfect lateral projections of the knees, a line was drawn along the posterior femoral shaft and another parallel line down the anterior femoral shaft. A 3rd line was then drawn parallel to the posterior shaft at the furthest point posterior on the condyle. A 4th line was drawn parallel to the anterior shaft at the furthest point anterior on the femur. 90 degree angles were constructed to create a grid in the anterior and posterior directions, similar to a previously reported technique. Finally, 45 degree angle lines were created in the grid to assess mid flexion dimensions [Fig-1 and 2]. The percent change in posterior condylar offset (PCO), anterior femoral offset (AFO), mid femoral anterior offset (MAFO) and mid femoral posterior offset (MFPO) were calculated. The mean reproduction of the mid-anterior femoral offset and mid-posterior femoral offset were 101.1% [range 56.5%–167.5%] and 96.8% [range 54.9%–149.0%] of preoperative measurements respectively. The average restoration of posterior offset and anterior offset were 92.8% [range 49.0%–129.8%] and 115.3% of preoperative measurements [range 35.7%–400.0%] respectively. When the posterior condylar offset was restored to within 10% of the native anatomy, the MPFO restoration more closely resembled normal anatomy (103.0% vs. 93.9%, p = 0.005). When the postoperative posterior condylar offset was decreased greater than 20%, both the MAFO (90.1% vs. 104.5%, p = 0.004) and MPFO (78.5% vs. 102.9%, p < 0.001) decreased compared to the native knee. There was no relationship between restoration of the PCO and the MAFO correction (104.6% vs. 99.4%, p = 0.213). Finally, there was no correlation between restoration of anterior femoral offset within 10% of normal and the restoration of mid sagittal femoral offset; 98.0% vs 102.0% for MAFO (p = 0.320) and 98.7% vs 96.3% for MPFO (p = 0.569). A modern multi-radius condylar knee design is capable of reproducing the mid-sagittal geometry of the preoperative knee. However, the restoration of mid sagittal offset is largely dependent on the restoration of the posterior condylar offset. Intraoperative adjustments in anterior and posterior femoral resections can have significant impact in the ability of the implant to reproduce mid-sagittal femoral anatomy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 103 - 103
1 Jan 2016
Kim Y Tanaka C Maki A Tada H Kanoe H Shirai T
Full Access

Periprosthetic femoral fractures are becoming increasingly common and are a major complication of total hip arthroplasty (THA) and bipolar hemiarthroplasty (BHA). We report a retrospective review of the outcomes of treatment of 11 periprosthetic fractures after femoral revision using a long stem. Eleven female patients with a mean age of 79.2 years (70 to 91 years) were treated for a Vancouver type B1 fracture between 1998 and 2013. The status of the initial arthroplasty was THA in 5 patients and BHA in 6 patients. The original diagnosis was femoral neck fracture in 5 patients, osteoarthritis in 5 patients, and avascular necrosis of femoral head in 1 patient. Seven patients had had a cemented femoral component and 4 had had a cementless femoral component. The mean numbers of previous surgeries were 3.2 times (2 to 5 times). A previous history of fracture in the same femur was found in 7 hips including 5 femoral neck fractures, 3 periprosthetic fractures. The cause of the latest revision surgery was aseptic loosening in 6 hips, periprosthetic fracture in 3 hips, and infection in 2 hips. The average time to fracture after femoral revision using a long stem was 106.5 months (12 to 240 months). The average follow-up was 58.9 months (8 to 180 months). The fracture pattern was a transverse fracture in 6 hips and an oblique fracture in 5 hips. The type B1 fractures were treated with open reduction and internal fixation in 9 hips, 6 of which were reinforced with bone grafts. Seven patients were treated with a locking compression plate and cerclage wiring, and 2 patients were treated with a Dall-Miles system. Two other periprosthetic fractures were treated with femoral revision. One was revised because of stem breakage, and the other was a transverse fracture associated with very poor bone quality, which received a femoral revision with a long stem and a locking compression plate. All fractures except one achieved primary union. This failed case had a bone defect at the fracture site, and revision surgery using a cementless long stem and allografts was successful. These finding suggest that a type B1 fracture after revision using a long stem associated with very poor bone quality or bone loss might be considered as a type B3 fracture, and femoral revision might be the treatment of choice


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 17 - 17
1 Jan 2016
Guyen O Bonin N Pibarot V Bejui-Hugues J
Full Access

Introduction. The value of collared stems for uncemented implants remains controversial. Some comparative studies have demonstrated advantages of collared stems regarding the potential for subsidence. Other studies with longer follow-up have shown no adverse effect of the use of a collar regarding the femoral component survivorship. To date, the adequate size of the collar with regards to the anatomy of the proximal femur has never been studied. The goal of this study was to assess whether the size of the collar needs to be adjusted according to the size of the femoral component used, and according to the use of a standard or a lateralized component. Materials and Method. 102 CT of normal femurs have been divided into 2 groups of 51 femurs each. Each group has been analysed by 2 independant surgeons. Each CT view passed through the axis of the proximal diaphysis and the center of the femoral head. The scale was 100%. Templates of femoral components have been set in order to reproduce the center of rotation and an optimal filling of the proximal femoral canal. Sizes of the femoral components as well as the need for standard or lateralized implants have been recorded. In order to determine the ideal size of the collar, the distance between the medial edge of the prothesis and the medial edge of the femur (so-called P-C distance) at the level of the neck cut (calcar) has been measured. Results. The inter-observer concordance for the selection of the implant type (i.e. standard or lateralized), size, and P-C distance measurement was satisfactory (kappa 0.7). 56% of the selected implants were standard. The mean size was 5 (1 to 10). The mean P-C distance was 9.9mm (5 to 16mm). It was 8.8mm for standard implants and 11.3mm for lateralized implants, with significant difference (p<0.0001). The size of the selected implant was significantly related to the P-C distance (r=0.27; p<0.005). Conclusion. These results suggest that the size of the collar should increase with larger sizes, and that the use of a longer collar with lateralized implants should be advocated


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 1 - 1
1 Apr 2022
Jahmani R Alorjan M
Full Access

Introduction. Femoral-shortening osteotomy for the treatment of leg length discrepancy is demanding technique. Many surgical technique and orthopaedic devises have been suggested to perform this procedure. Herein, we describe modified femoral shortening osteotomy over a nail, using a percutaneous multiple drill-hole osteotomy technique. Materials and Methods. We operated on six patients with LLD. Mean femoral shortening was 4.2 cm. Osteotomy was performed using a multiple drill-hole technique, and bone was stabilized using an intramedullary nail. Post-operative clinical and radiological data were reported. Results. Shortening was achieved, with a final LLD of < 1 cm in all patients. All patients considered the lengths of the lower limbs to be equal. No special surgical skills or instrumentation were needed. Intraoperative and post-operative complications were not recorded. Conclusions. Percutaneous femoral-shortening osteotomy over a nail using multiple drill-hole osteotomy technique was effective and safe in treating LLD