Abstract
Introduction
Femoral-shortening osteotomy for the treatment of leg length discrepancy is demanding technique. Many surgical technique and orthopaedic devises have been suggested to perform this procedure. Herein, we describe modified femoral shortening osteotomy over a nail, using a percutaneous multiple drill-hole osteotomy technique
Materials and Methods
We operated on six patients with LLD. Mean femoral shortening was 4.2 cm. Osteotomy was performed using a multiple drill-hole technique, and bone was stabilized using an intramedullary nail. Post-operative clinical and radiological data were reported.
Results
Shortening was achieved, with a final LLD of < 1 cm in all patients. All patients considered the lengths of the lower limbs to be equal. No special surgical skills or instrumentation were needed. Intraoperative and post-operative complications were not recorded.
Conclusions
Percutaneous femoral-shortening osteotomy over a nail using multiple drill-hole osteotomy technique was effective and safe in treating LLD