Advertisement for orthosearch.org.uk
Results 1 - 20 of 94
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1487 - 1490
1 Nov 2018
Teramoto A Shoji H Kura H Sakakibara Y Kamiya T Watanabe K Yamashita T

Aims

The aims of this study were to evaluate the morphology of the ankle in patients with an osteochondral lesion of the talus using 3D CT, and to investigate factors that predispose to this condition.

Patients and Methods

The study involved 19 patients (19 ankles) who underwent surgery for a medial osteochondral lesion (OLT group) and a control group of 19 healthy patients (19 ankles) without ankle pathology. The mean age was significantly lower in the OLT group than in the control group (27.0 vs 38.9 years; p = 0.02). There were 13 men and six women in each group. 3D CT models of the ankle were made based on Digital Imaging and Communications in Medicine (DICOM) data. The medial malleolar articular and tibial plafond surface, and the medial and lateral surface area of the trochlea of the talus were defined. The tibial axis-medial malleolus (TMM) angle, the medial malleolar surface area and volume (MMA and MMV) and the anterior opening angle of the talus were measured.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 156 - 157
1 May 2011
Wuestemann T Bastian A Schmidt W Cedermark C Streicher R Parvizi J Rothman R
Full Access

Introduction: Clinical experience has shown that addressing variations in bone morphology is important in the development of successful hip implant designs. Numerous studies of femoral bone morphology have been published utilizing various techniques. This study has developed a method which consistently measures large quantities of 3-dimensional digital femura geometry segmented from computed tomography (CT) scans and can accurately make anatomical measurements from these images. Methods: CT images of left femora on five hundred fifty six left femura (57% male, 43% female), consisting of 69% Caucasian, 16% Asian and 14% unknown were analyzed. The average age was 66 years, ranging from 40 to 93 years. Segmentation of the outer cortical, inner cortical, and marrow boundaries were consistently performed over all CT scans. The positions identified on the reference bone are transformed to the equivalent position on the clinical bone images, from which the dimensional data is extracted and stored. The mediolateral width (MLW), medial offset (MO) and lateral offset (LO) were measured in 10mm increments, ranging from 20mm above the lesser trochanter (LT) to 130mm below the lesser trochanter. The canal flare index was defined as a ratio of the mediolateral width at a section 20mm above the lesser trochanter to the mediolateral width at the isthmus level. Results: The mean mediolateral width at 20mm above the lesser trochanter was 47.0 ± 4.5 (35.1–61.8; n=556). Noble reported 45.4 ± 5.3 (31.0–60.0; n=200), Husmann reported in a neck oriented study 46.3 ± 6.9 (27.6–63.6; n=310) and Laine reported 47.1 ± 4.9 (n=50). The mean medial offset at a section 20mm above the lesser trochanter was 25.1 ± 2.9 (16.7–33.4). In the study by Husmann, a mean of 25.0 ± 5.2 (9.4–45.5) was reported. The mean canal flare index was 4.49 ±.8. Noble reported a mean canal flare index of 3.80 ±.074, Husmann 3.81 ±.83 and Laine 4.3 ±.93. Discussion: In general, the study showed minor differences to published data of proximal bone morphology. However, this more powerful study has shown that there is a higher mean canal flare index than determined by Noble and a similar mean canal flare index as determined by Laine. As reported by Laine, the canal flare index varies significantly with the placement of measurements in the canal. In this study the measurements were performed in a plane oriented by the femoral neck as a hip stem would be placed. The CFI over the isthmus width showed a greater correlation than previously shown by Noble. The novel software tool allows for anatomical measurements that can be applied to an unlimited population size enabling further applications and studies


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 122 - 122
1 Aug 2013
Hefny M Rudan J Ellis R
Full Access

INTRODUCTION. Understanding bone morphology is essential for successful computer assisted orthopaedic surgery, where definition of normal anatomical variations and abnormal morphological patterns can assist in surgical planning and evaluation of outcomes. The proximal femur was the anatomical target of the study described here. Orthopaedic surgeons have studied femoral geometry using 2D and 3D radiographs for precise fit of bone-implant with biological fixation. METHOD. The use of a Statistical Shape Model (SSM) is a promising venue for understanding bone morphologies and for deriving generic description of normal anatomy. A SSM uses measures of statistics on geometrical descriptions over a population. Current SSM construction methods, based on Principal Component Analysis (PCA), assume that shape morphologies can be modeled by pure point translations. Complicated morphologies, such as the femoral head-neck junction that has non-rigid components, can be poorly explained by PCA. In this work, we showed that PCA was impotent for processing complex deformations of the proximal femur and propose in its place our Principal Tangent Component (PTC) analysis. The new method used the Lie algebra of affine transformation matrices to perform simple computations, in tangent spaces, that corresponded to complex deformations on the data manifold. RESULTS. Both PCA and PTC were applied to the proximal femur dataset, from which selected femurs were reconstructed using the accumulation of components. PCA was deemed to have failed to reconstruct the surfaces because it required 65 components to achieve high coverage of the dataset. An important observation was that the head-neck junction was the most difficult section in the femur, requiring more components than other anatomical regions to reconstruct. This finding is consistent with the surgical observation that deformations occur in this junction for abnormal hip morphologies. PTC was successful in recovering 100% of the medical data using the only the first 5 components. We note that the encoding of deformation in PTC accounting for the performance increase. PTC outperformed PCA on the dataset in descriptive compactness. CONCLUSION. A standard SSM construction method was not adequate for analysing proximal femur surfaces because it could not easily model the complexity of non-rigid deformations at the head-neck junction. Principal tangent components, a novel method for using exponential maps on manifolds, accurately reconstructed the anatomical surfaces with very few components. Future work may include extending these concepts to describe joint diseases based on the shape of surfaces derived from volumetric data, such as CT or MRI. In conclusion, we have shown that differential geometry may be provide new insights to computational anatomy applications


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 126 - 126
1 Feb 2017
Lo D Lipman J Hotchkiss R Wright T
Full Access

Introduction. The first carpometacarpal (CMC) joint is the second most common joint of the hand affected by degenerative osteoarthritis (OA). 1. Laxity of ligamentous stabilizers that attach the first metacarpal bone (MC1) and the trapezium bone (TZ), notably the volar anterior oblique ligament (AOL), has been associated with cartilage wear, joint space narrowing, osteophyte formation, and dorsal-radial CMC subluxation. 2. In addition, the proximal-volar end of the MC1 has a bony prominence known as the palmar lip (PL) that adds conformity to this double-saddle joint, and is thought to be a supplemental dorsal stabilizer. Currently, no study has looked at the changes to the 3D shape and relative positions of these structures with OA. Methods. CT scans of patients with clinically diagnosed CMC OA (n=11, mean age 73 [60–97], 8 females) and CT scans of ‘normal’ patients with no documented history of CMC OA (n=11, mean age 37 [20–51], 6 females) were obtained with the hand in a prone position. 3D reconstructions of the MC1 and TZ bones were created, and each assigned a coordinate system. 3. The long axis of the MC1 and the proximal-distal axis of the TZ were established, and the location where they intersected the CMC articular surface was defined as their articular center points, X and O, respectively (Figure 1). Using the TZ as a fixed reference, we calculated the relative position of X in the dorsal-ventral and radial-ulnar directions. A two sample t-test was performed to compare the normal and OA groups. In addition, the distal position of the PL relative to X was recorded. Results. The dorsal position of the MC1 relative to the TZ was significantly greater (p=0.002) in the OA group compared with the normal group, with mean dorsal positions of 7.1 and 3.2mm, respectively (Figure 2). The distal position of the PL relative to X was also significantly greater (p=0.001) in the OA group when compared with the normal group, with mean positions of 5.8 and 1.9mm, respectively (Figure 3). Discussion. Dorsal migration of the MC1 in the OA group would suggest a compromised AOL, known to be elongated or absent intraoperatively. Without a sufficient AOL, the PL was positioned more distally in the OA group, as the load on the PL during extension activities could possibly exceed cartilage strength resulting in subchondral bone remodeling and further joint degeneration. We did not observe radial migration of the MC1 bone possibly due to the presence of bony osteophytes that can reduce abduction-adduction function in OA patients. 4. The relationship discovered between OA and changes to bone morphology and relative bone positions of the CMC joint may provide further insight into the natural progression of this disease


Bone strength is influenced by bone quality besides its density. This study aimed to evaluate the effects of teriparatide on changes of bone strength as well as trabecular and cortical bone microstructures at femoral neck in female ovariectomized (OVX) rats. Eighteen female Wister rats were divided into three groups: the sham control, OVX and treatment (Tx) groups. All of them were sacrificed after 3-month intermittent teriparatide intervention in Tx group. All left femurs were removed and scanned using micro-CT and followed by mechanical test for each femoral neck. Regarding micro-CT, four trabecular parameters including bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular separation (TbSp), and trabecular number (TbN) and three cortical parameters including volumetric bone mineral density (vBMD), cortical cross-sectional area (CtAr) and cortical thickness (CtTh) were measured at femoral neck region. All data were analyzed and was presented as median ± SEM. The mean bone strength of femoral neck significantly decreased in OVX group when compared to the control group (p < 0.05) and was significantly restored in Tx group (p < 0.01). Regarding the trabecular parameters, the BV/TV and TbTh significantly decreased in OVX group while compare to Tx group. However, no significant difference was observed in TbSp and TbN between the groups. Regarding the cortical parameters, CtTh was significantly greater in Tx group than that in OVX group (p<0.01). As our findings, intermittent teriparatide can improve the deteriorated bone strength of femoral neck due to ovarian deficiency via changing both trabecular microarchitecture and cortical morphology.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims

Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia.

Methods

The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 124 - 124
4 Apr 2023
van Knegsel K Hsu C Huang K Benca E Ganse B Pastor T Gueorguiev B Varga P Knobe M
Full Access

The lateral wall thickness (LWT) in trochanteric femoral fractures is a known predictive factor for postoperative fracture stability. Currently, the AO/OTA classification uses a patient non-specific measure to assess the absolute LWT (aLWT) and distinguish stable A1.3 from unstable A2.1 fractures based on a threshold of 20.5 mm. This approach potentially results in interpatient deviations due to different bone morphologies and consequently variations in fracture stability. Therefore, the aim of this study was to explore whether a patient-specific measure for assessment of the relative LWT (rLWT) results in a more precise threshold for prediction of unstable fractures. Part 1 of the study evaluated 146 pelvic radiographs to assess left-right symmetry with regard to caput-collum-angle (CCD) and total trochanteric thickness (TTT), and used the results to establish the rLWT measurement technique. Part 2 reevaluated 202 patients from a previous study cohort to analyze their rLWT versus aLWT for optimization purposes. Findings in Part 1 demonstrated a bilateral symmetry of the femur regarding both CCD and TTT (p ≥ 0.827) allowing to mirror bone's morphology and geometry from the contralateral intact to the fractured femur. Outcomes in Part 2 resulted in an increased accuracy for the new determined rLWT threshold (50.5%) versus the standard 20.5 mm aLWT threshold, with sensitivity of 83.7% versus 82.7% and specificity 81.3% versus 77.8%, respectively. The novel patient-specific rLWT measure can be based on the contralateral femur anatomy and is a more accurate predictor of a secondary lateral wall fracture in comparison to the conventional aLWT. This study established the threshold of 50.5% rLWT as a reference value for prediction of fracture stability and selection of an appropriate implant for fixation of trochanteric femoral fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 70 - 70
2 Jan 2024
Ely E Collins K Lenz K Paradi S Liedtke W Chen Y Guilak F
Full Access

Osteoarthritis (OA) is the leading cause of pain and disability worldwide and is characterized by the degenerative changes of articular cartilage. Joint loading is required for cartilage maintenance; however, hyper-physiologic loading is a risk factor for OA. Mechanosensitive ion channels Piezo1 and Piezo2 synergistically transduce hyper-physiologic compression of chondrocytes, leading to chondrocyte death and onset of OA. This injury response is inhibited by Piezo channel loss of function, however the mechanistic role of Piezo channels in vivo is unknown. We examined the hypothesis that deletion of Piezo in chondrocytes will protect mice from joint damage and pain-related behaviors following a surgical destabilization of the medial meniscus (DMM), investigating a key mechanistic and mechanobiological role of these channels in the pathogenesis of OA. Aggrecan-Cre Piezo1 and Piezo1/2 knockout mice ((Agc)1-CRE. ERT2. ;Piezo1. fl/fl. Piezo2. fl/fl. ) were generated and given a 5-day Tamoxifen regimen at 12-weeks of age (n=6–12/group/sex). Cre-negative mice served as controls. At 16-weeks, mice received DMM surgery on the left knee. 12-weeks following DMM prior to sacrifice, activity and hyperalgesia were measured using spontaneous running wheels and a small animal algometer. Structural changes in bone, cartilage, and synovium were characterized using microCT, histology, and Modified Mankin Score criteria. Knockout of Piezo1/2 channels was chondroprotective in both sexes following DMM surgery as demonstrated by reduced Modified Mankin Score compared to control animals. Piezo1 KO was chondroprotective in only female mice, indicating a sexually dimorphic response. Piezo1 and Piezo1/2 KO was protective against pain in male mice, while females displayed no differences compared to controls. No changes were observed in bone morphology. Chondrocyte-specific Piezo1/2 knockout protects the knee joint from structural damage, hyperalgesia and functional deficits in a surgical model of PTOA in male and female mice, illustrating the importance of Piezo channels in response to injury in vivo. Future work aims to interrogate potential sexually dimorphic responses to cartilage damage and investigating Piezo2 KO mice


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 69 - 69
1 Dec 2016
Kopka M Rahnemani-Azar A Abebe E Labrum J Irrgang J Fu F Musahl V
Full Access

Knee laxity following anterior cruciate ligament (ACL) injury is a complex phenomenon influenced by various biomechanical and anatomical factors. The contribution of soft tissue injuries – such as ligaments, menisci, and capsule – has been previously defined, but less is known about the effects of bony morphology. (Tanaka et al, KSSTA 2012) The pivot shift test is frequently employed in the clinical setting to assess the combined rotational and translational laxity of the ACL deficient knee. In order to standardise the maneuver and allow for reproducible interpretation, the quantitative pivot shift test was developed. (Hoshino et al, KSSTA 2013) The aim of this study is to employ the quantitative pivot shift test to determine the effects of bone morphology as determined by magnetic resonance imaging (MRI) on rotatory laxity of the ACL deficient knee. Fifty-three ACL injured patients scheduled for surgical reconstruction (36 males and 17 females; 26±10 years) were prospectively enrolled in the study. Preoperative magnetic resonance imaging (MRI) scans were reviewed by two blinded observers and the following parameters were measured: medial and lateral tibial slope, tibial plateau width, femoral condyle width, bicondylar width, and notch width. (Musahl et al. KSSTA 2012). Preoperatively and under anaesthesia, a quantitative pivot shift test was performed on each patient by a single experienced examiner. An image analysis technique was used to quantify the lateral compartment translation during the maneuver. Subjects were classified as “high laxity” or “low laxity” based upon the median value of lateral compartment translation. (Hoshino et al. KSSTA 2012) Independent t-tests and univariate logistic regression were used to investigate the relationship between the pivot shift grade and various features of bone morphology. Statistical significance was set at p<0.05. A high inter-rater reliability was observed in all MRI measurements of bone morphology (ICC=0.72–0.88). The median lateral compartment translation during quantitative pivot shift testing was 2.8mm. Twenty-nine subjects were classified as “low laxity” (2.8mm). The lateral tibial plateau slope was significantly increased in “high laxity” patients (9.3+/−3.4mm versus 6.1+/−3.7mm; p<0.05). No other significant difference in bone morphology was observed between the groups. This study employed an objective assessment tool – the quantitative pivot shift test – to assess the contribution of various features of bone morphology to rotatory laxity in the ACL deficient knee. Increased lateral tibial plateau slope was shown to be a significant independent predictor of high laxity. These findings could help guide treatment strategies in patients with high grade rotatory laxity. Further research into the role of tibial osteotomies in this sub-group is warranted


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 29 - 29
1 Nov 2021
Micheletti C Shah FA Grandfield K Palmquist A
Full Access

Introduction and Objective. Type 2 diabetes mellitus (T2DM), and the often concurrent obesity, causes metabolic changes that affect many organs and tissues, including bone. Despite a normal or even higher bone mineral density (BMD), T2DM has often been associated with a higher fracture risk, indicating a compromised bone quality. In this work, we use a novel congenic leptin receptor-deficient BioBreeding Diabetes Resistant rat (BBDR.cg.lepr.cp) to investigate the impact of T2DM and obesity on bone morphology and architecture at the microscale. Materials and Methods. Two different anatomical locations, i.e., femur and cranium, were studied combining micro-computed X-ray tomography (micro-CT) with scanning electron microscopy (SEM). Micro-CT data were examined using advanced image analysis tools in three-dimensions (3D). Results. Both parietal bones and femurs were smaller, i.e., thinner and shorter, respectively, in diabetic animals compared to healthy controls. Image analysis of the sagittal suture revealed a reduced suture width and length in diabetic animals, suggesting an altered bone apposition rate. Histomorphometry analysis from micro-CT data highlighted differences in microstructure of both trabecular and cortical femur between diabetic and healthy rats. In particular, bone volume fraction (BV/TV) was lower in the T2DM group, while trabecular spacing (Tb.Sp) was increased, overall indicating a higher porosity in diabetic trabecular bone. SEM revealed the presence of extended portions of hyper-mineralized cartilage in the distal femur of the diabetic animals. Conclusions. Micro-CT analyses, combined with SEM imaging, suggest that T2DM impacts bone growth and remodelling, in turn leading to differences in the structural organization at the microscale


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 25 - 25
1 Nov 2021
Alpaugh K Chiu Y Zlotnicki J Bendich I Della Valle A Bostrom M Gausden E
Full Access

Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor bone quality, surgical approach and cementless implants. The association between femoral component size and alignment and the risk of early PFF is not well described. We evaluated radiographic parameters of femoral component sizing and alignment as risk factors for early PFF. From 16,065 primary cementless THA, we identified 66 cases (0.41%) of early PFF (<90 days from index THA) at a single institution between 2016–2020. The stem was unstable and revised in all cases. We matched 60 cases of early PFFs (2:1) to 120 controls based on femoral component model, offset, surgical approach, age, BMI, and sex. Mean age was 67 years; 60% were female. Radiographic assessment of preoperative bone morphology and postoperative femoral component parameters including stem alignment, metaphyseal fill, and medial congruence with the calcar. A multivariable logistic regression was built to identify radiographic risk factors associated with early PPF. Markers of poor preoperative bone quality including canal calcar ratio (p=0.003), canal flare index (p<0.001), anteroposterior canal bone ratio (CBR) (p<0.001) and lateral CBR (p<0.001) were statistically associated with PFF. Valgus alignment (23% versus 12%) (p<0.001) was more prevalent in the PFF group compared to controls, as well as varus alignment of the implant (57% versus 43%). Distance between the medial aspect of the implant and the calcar was greater in cases of PFF (2.5 mm versus 1.4 mm) (p<0.001). Multivariate analysis demonstrated that valgus implant alignment (Odds Ratio (OR) 5) and medial implant-calcar incongruity (OR 2) increased the risk of early PFF. Medial implant-calcar incongruity and valgus alignment of the femoral component were risk factors for early PFF following cementless THA after controlling for age, sex, BMI, approach, proximal femoral morphology, and implant design


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 822 - 827
1 May 2021
Buzzatti L Keelson B Vanlauwe J Buls N De Mey J Vandemeulebroucke J Cattrysse E Scheerlinck T

Evaluating musculoskeletal conditions of the lower limb and understanding the pathophysiology of complex bone kinematics is challenging. Static images do not take into account the dynamic component of relative bone motion and muscle activation. Fluoroscopy and dynamic MRI have important limitations. Dynamic CT (4D-CT) is an emerging alternative that combines high spatial and temporal resolution, with an increased availability in clinical practice. 4D-CT allows simultaneous visualization of bone morphology and joint kinematics. This unique combination makes it an ideal tool to evaluate functional disorders of the musculoskeletal system. In the lower limb, 4D-CT has been used to diagnose femoroacetabular impingement, patellofemoral, ankle and subtalar joint instability, or reduced range of motion. 4D-CT has also been used to demonstrate the effect of surgery, mainly on patellar instability. 4D-CT will need further research and validation before it can be widely used in clinical practice. We believe, however, it is here to stay, and will become a reference in the diagnosis of lower limb conditions and the evaluation of treatment options. Cite this article: Bone Joint J 2021;103-B(5):822–827


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 33 - 33
1 Mar 2021
Koria L Farndon M Lavalette D Jones E Mengoni M Brockett C
Full Access

Abstract. Objectives. Over 1% of the global population suffers with ankle osteoarthritis (OA), yet there is limited knowledge on the changes to subchondral bone with OA. In other joints, it has been shown that bone becomes osteosclerotic, with fewer, thicker trabeculae that become hypomineralised, causing an increased apparent bone volume fraction (BV/TV). Microstructural alterations reduce overall joint strength, which may impact the success of late-stage surgical interventions, such as total ankle arthroplasty (TAA). Previous ankle studies have evaluated changes to cartilage, bone plate and bone morphology with OA, hence this study aimed to characterise changes to trabecular architecture. Methods. Three ankle joints were isolated from non-diseased cadaveric feet (three males: 43, 50 and 57 years, MEEC 18-027). Cylindrical subchondral bone specimens (N=6, 6.5 mm Ø) were extracted from the tibial plafond. Osteoarthritic bone samples (N=6, distal tibia) were sourced from local patients (three males: 65, 58 and 68 years, NREC 07/Q1205/27) undergoing TAA surgery. Specimens were imaged using µCT at a 16 µm isotropic resolution (µCT-100 ScanCo Medical). Virtual cores of bone (6.5 mm Ø) were extracted from the image data of the osteoarthritic specimens and trimmed to a height of 4 mm. BoneJ was used to evaluate key morphological indices: BV/TV; anisotropy (DA); trabecular thickness (Tb.Th); trabecular density (Conn.D) and ellipsoid factor (EF) which characterises rod/plate geometry. Differences between the two groups of specimens were evaluated using a t-test with Bonferroni correction. Results. Significant increases in BV/TV and Tb.Th (p<0.01) were observed with OA compared to non-diseased. Differences in EF showed a shift to more rod-dominated structure with OA, but this was not significant. No significant differences to DA and Conn.D were observed. Conclusions. The results of this study agree with trends observed in other OA joints, but would benefit from a larger sample size. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 36 - 36
1 Feb 2021
Spece H Kurtz S Yu T Marcolongo M Law A
Full Access

Introduction. The ability to create patient-specific implants (PSI) at the point-of-care has become a desire for clinicians wanting to provide affordable and customized treatment. While some hospitals have already adopted extrusion-based 3D printing (fused filament fabrication; FFF) for creating non-implantable instruments, recent innovations have allowed for the printing of high-temperature implantable polymers including polyetheretherketone (PEEK). With interest in FFF PEEK implants growing, it is important to identify methods for printing favorable implant characteristics such as porosity for osseointegration. In this study, we assess the effect of porous geometry on the cell response and mechanical properties for FFF-printed porous PEEK. We also demonstrate the ability to design and print customized porous implants, specifically for a sheep tibial segmental defect model, based on CT images and using the geometry of triply periodic minimal surfaces (TPMS). Methods. Three porous constructs – a rectilinear pattern and gyroid/diamond TPMSs – were designed to mimic trabecular bone morphology and manufactured via PEEK FFF. TPMSs were designed by altering their respective equation approximations to achieve desired porous characteristics, and the meshes were solidified and shaped using a CAD workflow. Printed samples were mCT scanned to determine the resulting pore size and porosity, then seeded with pre-osteoblast cells for 7 and 14 days. Cell proliferation and alkaline phosphatase activity (ALP) were evaluated, and the samples were imaged via SEM. The structures were tested in compression, and stiffness and yield strength values were determined from resulting stress-strain plots. Roughness was determined using optical profilometry. Finally, our process of porous structure design/creation was modified to establish a proof-of-concept workflow for creating PSIs using geometry established from segmented sheep tibia CT images. Results. ALP activity measurements of the porous PEEK samples at 7 and 14 days were significantly greater than for solid controls (p < 0.001 for all three designs, 14 days). No difference between the porous geometries was found. SEM imaging revealed cells with flat, elongated morphology attached to the surface of the PEEK and into the pore openings, with filopodia and lamellipodia extensions apparent. mCT imaging showed average pore size to be 545 ± 43 µm (porosity 70%), 708 ± 64 µm (porosity 68%), and 596 ± 94 µm (porosity 69%) for the rectilinear, gyroid, and diamond structures, respectively. The average error between the theoretical and actual values was −16.3 µm (pore size) and −3.3 % (porosity). Compression testing revealed elastic moduli ranging from 210 to 268 MPa for the porous samples. Yield strengths were 6.6 ± 1.2 MPa for lattice, 14.8 ± 0.7 MPa for gyroid, and 17.1 ± 0.6 for diamond. Average roughness ranged from 0.8 to 3 µm. Finally, we demonstrated the ability to design and print a fully porous implant with the geometry of a sheep tibia segment. Assessments of implant geometrical accuracy and mechanical performance are ongoing. Discussion. We created porous PEEK with TPMS geometries via FFF and demonstrated a positive cellular response and mechanical characteristics similar to trabecular bone. Our work offers an innovative approach for advancing point-of-care 3D printing and PSI creation


Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims

The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy.

Methods

We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 70 - 70
1 Aug 2020
Montreuil J Lavoie F Thibeault F Cresson T de Guise J
Full Access

Evaluate precisely and reproducibly tridimensional positioning of bone tunnels in anterior cruciate ligament reconstructions (ACL). To propose biplanar stereoradiographic imaging as a new reference in tridimensional evaluation of ACL reconstruction (ACLR). Comparing knee 3D models issued from EOStm low-irradiation biplanar X-Ray with those issued from computed tomography (CT-Scan) high definition images will allow a bone morphological description of a previously unseen precision. We carried out the transfer of 3D models from EOStm X-Ray images obtained from 10 patients in the same reference frame with models issued from CT-Scan. Two evaluators reconstructed both pre-operative and post-operative knees, using two different stereoradiographic projections, for a total of 144 knee 3D models from EOStm. A surface analysis by distance mapping allowed us to know the differences or errors between the homologous points of the EOStm and CT reconstructions, the latter being our “bronze-standard”. At the femur, we obtained a mean (95% confidence level) error of 1.5 mm (1.3–1.6) between the EOStm models compared to the Arthro-CT segmentations when using AP-LAT incidences, compared to 1 mm (1.0 – 1.1) with oblique projections. For the tunnels placement analysis, the total radius difference between EOStm and Arthro-CT's femoral tunnel apertures was 0.8 mm (0.4–1.2) in AP-LAT and 0.6 mm (0.0–1.2) in oblique views. These femoral apertures positioning on EOStm models were within 4.3 mm (3.0–5.7) of their homologues on CT-Scan models, 4.6 mm (3.5–5.6) with the oblique views. Furthermore, 9.3o (7.2–11.4) of difference in direction between femoral tunnels from EOStm models and CT reconstructions is obtained with AP-LAT projections, 8.3o (6.6–10) with obliques views. Measures of these parameters were also performed at the tibia. According to the intra and inter-reproducibility analysis of our knee 3D models, EOStm biplanar X-Ray images prove to be fast, efficient and precise in the design of ACLR 3D models with respect to CT-Scan. Our results also propose the recourse of oblique stereoradiographic projections for the realization of knee 3D models. These models will be subjects of further analysis and will allow us eventually to propose a new frame of reference guiding the positioning of the tunnels in the ACLR


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1058 - 1062
1 Sep 2019
van Kuijk KSR Reijman M Bierma-Zeinstra SMA Waarsing JH Meuffels DE

Aims. Little is known about the risk factors that predispose to a rupture of the posterior cruciate ligament (PCL). Identifying risk factors is the first step in trying to prevent a rupture of the PCL from occurring. The morphology of the knee in patients who rupture their PCL may differ from that of control patients. The purpose of this study was to identify any variations in bone morphology that are related to a PCL. Patients and Methods. We compared the anteroposterior (AP), lateral, and Rosenberg view radiographs of 94 patients with a ruptured PCL to a control group of 168 patients matched by age, sex, and body mass index (BMI), but with an intact PCL after a knee injury. Statistical shape modelling software was used to assess the shape of the knee and determine any difference in anatomical landmarks. Results. We found shape variants on the AP and Rosenberg view radiographs to be significantly different between patients who tore their PCL and those with an intact PCL after a knee injury. Overall, patients who ruptured their PCL have smaller intercondylar notches and smaller tibial eminences than control patients. Conclusion. This study shows that differences in the shape of the knee are associated with the presence of a PCL rupture after injury. A smaller and more sharply angled intercondylar notch and a more flattened tibial eminence are related to PCL rupture. This suggests that the morphology of the knee is a risk factor for sustaining a PCL rupture. Cite this article: Bone Joint J 2019;101-B:1058–1062


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 2 - 2
1 Jan 2016
Mabuchi K Uchida K Ito T Shimizu K Nakao M Naruse K Sakai R
Full Access

INTRODUCTION. It is generally accepted that strong hammering is necessary for the press fit fixation of a joint prosthesis. In this regard, large stress must remain within bone tissues for a long period. This residual stress is, however, some different from the feasible mechanical stimuli for bone tissues because that is stationary, continuous and directed from within outward unlike physiological conditions. The response on this residual stress, which may induce the disorder of the fixation of implant, has not been discussed, yet. In the present study, we designed an experimental method to exert a stationary load from inside of a femur of a rat by inserting a loop spring made from a super elastic wire of titanium alloy. Response of the femur was assessed by bone morphology mainly about the migration of the wire into the bone twelve weeks after the implantation. MATERIALS AND METHODS. We developed a method using a loop spring made of super elastic wire of titanium alloy, which can maintain sufficient magnitude of stress in a rat femur during the experimental period. The loop spring was fabricated with a wire of 0.4 mm diameter before the quenching process. Eleven Wistar rats of ten weeks old were used for the experiments. The loop spring was inserted the right femur, as shown in Figure 1. The left femur was remained intact. The compressive load was added from within outward of bone marrow when the spring was compressed with the insertion into a bone marrow of a rat femur, as shown in Figure 2. The average contact stress was calculated by dividing the elastic force by the spring and bone contact area. The contact stress was distributed from 62 to 94 MPa, which are sufficiently lower than the yield stress of cortical bone [1]. The assessment of bone morphology around the implanted loop spring was performed by micro-CT imaging after the twelve weeks of cage activity. RESULTS. To assess the migration of the spring in the femur, we measured the distance from the endocortical surface to the periphery of the spring, on the micro CT image, as shown in Figure 3. Apparent migration of the spring wire was observed on nine specimens among the eleven. Deep migration over 0.3 mm was observed at three cases. DISCUSSION. The migration of the wire in cortical bone was accompanied with the bone resorption on the surface of the wire toward outside. Therefore, the present findings suggest that stationary load at the implant surface can induce endosteal bone resorption and prosthesis dislocation and protrusion. CONCLUSION. We developed a method for configuring a stationary stress field in a rat femur using a loop spring with the super elasticity. It was found that stationary stress about 70 MPa can induce bone resorption


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1235 - 1238
1 Dec 2023
Kader DF Jones S Haddad FS