Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 10 - 18
1 Jun 2020
Ueyama H Kanemoto N Minoda Y Taniguchi Y Nakamura H

Aims

The aim of this study was to assess the effectiveness of perioperative essential amino acid (EAA) supplementation to prevent rectus femoris muscle atrophy and facilitate early recovery of function after total knee arthroplasty (TKA).

Methods

The study involved 60 patients who underwent unilateral TKA for primary knee osteo-arthritis (OA). This was a double-blind, placebo-controlled, randomized control trial with patients randomly allocated to two groups, 30 patients each: the essential amino acid supplementation (9 g daily) and placebo (lactose powder, 9 g daily) groups. Supplementation and placebo were provided from one week before to two weeks after surgery. The area of the rectus femoris muscle were measured by ultrasound imaging one month before surgery and one, two, three, and four weeks postoperatively. The serum albumin level, a visual analogue knee pain score, and mobility were also measured at each time point. The time to recovery of activities of daily living (ADLs) was recorded. Postoperative nutrition and physiotherapy were identical in both groups.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims. The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery. Methods. A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA. Results. Survivorship at ten years was 97% in both the ACL-deficient and ACL-intact groups. The mean survival was 16.1 years (95% confidence interval (CI) 15.3 to 16.8) for the ACL-deficient group and 15.6 years (95% CI 14.8 to 16.361) for the ACL-intact group (p = 0.878). At a mean of nine years (SD 3.5) in the ACL-deficient group, 32 patients (87%) reached the PASS for the KOOS ADL. In the ACL-intact group, at a mean of 8.6 years (SD 3) follow-up, 63 patients (85%) reached PASS for the KOOS ADL. There was no significant difference in the percentage of patients who reached PASS for all KOOS subscales and Lysholm between the two groups. Conclusion. PASS was achieved in 85% of all UKAs for KOOS ADL, similar to reports for TKA. Fixed-bearing, medial, non-robotically-assisted UKA resulted in 97% survival at ten years in both the ACL-deficient and ACL-intact groups. There was no significant difference in all outcomes between the two groups. Understanding PASS will allow better communication between surgeons and patients to improve the surgical management of patients with single compartment OA of the knee. This study provides mid- to long-term data supporting the use of PASS to document outcomes following UKA. PASS was met in more than 85% of patients with no differences between ACL-deficient and ACL-intact knees at a mean follow-up of nine years. Cite this article: Bone Joint J 2021;103-B(8):1367–1372


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1336 - 1344
1 Oct 2018
Powell AJ Crua E Chong BC Gordon R McAuslan A Pitto RP Clatworthy MG

Aims. This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. Patients and Methods. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m. 2. (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups. Results. At the ten-year follow-up, the RP group (n = 39) had a statistically significant superior score in the OKS (p = 0.001), WOMAC (p = 0.023), SF-12 PCS (p = 0.019), KOOS Activities of Daily Living (ADL) (p = 0.010), and KOOS Sport and Recreation (Sport/Rec) (p = 0.006) compared with the FB group (n = 46). The OKS, SF-12 PCS, and KOOS Sport/Rec at ten years had mean scores above the minimal clinically important difference (MCID) threshold. There was no significant difference in prevalence of radiolucency between groups at five-years’ follow-up (p = 0.449), nor at ten-years’ follow-up (p = 0.08). Implant survival rate at 14 years postoperative was 95.2 (95% CI 90.7 to 99.8) and 94.7 (95% CI 86.8 to 100.0) for the RP and FB TKAs, respectively. Conclusion. At ten-year follow-up, the mobile-bearing knee joint arthroplasty had statistically and clinically relevant superior OKS, SF-12 PCS, and KOOS (Sport/Rec) than the fixed-bearing platform. No difference was seen in prevalence of radiolucent lines. There was a greater than 94% implant survival rate for both cohorts at 14 years. Cite this article: Bone Joint J 2018;100-B:1336–44


Bone & Joint Open
Vol. 2, Issue 9 | Pages 737 - 744
1 Sep 2021
Øhrn F Lian ØB Tsukanaka M Röhrl SM

Aims. Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA. Methods. A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m. 2. (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved. Results. MTPMs at three, 12, and 24 months were 1.0 mm (95% CI 0.8 to 1.2), 1.3 mm (95% CI 0.9 to 1.7), and 1.4 mm (0.8 to 2.0), respectively. The Forgotten Joint Score was 79 (95% CI 39 to 95) and Knee Injury and Osteoarthritis Outcome Score obtained at two years was 94 (95% CI 81 to 100), 86 (95% CI 75 to 93), 94 (95% CI 88 to 100), 69 (95% CI 48 to 88), and 81 (95% CI59 to 100) for Pain, Symptoms, Activities of Daily Living, Sport & Recreation, and Quality of Life, respectively. Conclusion. In conclusion, we found that the mean increase in MTPM was lower than 0.2 mm between 12 and 24 months and thus apparently stable. Yet the GMK Sphere had higher migration at one and two years than anticipated. Based on current RSA data, we therefore cannot conclude on the long-term performance of the implant, pending further assessment. Cite this article: Bone Jt Open 2021;2(9):737–744


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 3 - 3
1 Oct 2018
Catani F Zambianchi F Marcovigi A Franceschi G Nardacchione R
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated the reliability of robotic assisted UKA over manual UKA in component placement and executing a soft-tissue tensioning plan. The purpose of this multicenter study was to determine the correlation between 3D component positioning and soft-tissue tensioning with short-term clinical results following robotic assisted medial UKA. Methods. Between 2013 and 2016, 349 patients (381 knees) underwent robotic assisted fixed bearing metal backed medial UKAs at two centres. Follow-up was performed at 12 months minimum. Pre- and post-operatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS), Forgotten Joint Score 12 (FJS), and Short-Form summary scale (SF-12) surveys. Clinical results for every score were stratified as ‘excellent’, ‘mild’ and ‘insufficient’. Post-operative complications were recorded. Failure mechanisms, reoperations and post-operative knee pain were also assessed. Intra-operative robotic data relative to femoral and tibial component placement in the coronal, sagittal and horizontal plane, as well as femoro-tibial gaps at different knee flexion angles were also collected. Results. A total of 338 robotic assisted medial UKAs (309 patients) were assessed at an average follow-up of 33.5 months post-operatively (89% follow-up rate). Three implants were revised, resulting in a survivorship of 99.0% (C.I. 97.0%–99.7%), one for prosthetic joint infection and two for tibial aseptic loosening. All clinical post-operative scores were significantly improved from the pre-operative scores. The following statistically significant correlations were found between intra-operative robotic data and outcomes considered individually: femoral component coronal alignment influenced KOOS Symptoms, Pain and Quality of Life (p<0.05), sagittal alignment influenced KOOS Symptoms and Pain (p<0.05), and femoro-tibial gaps at 20°–30° knee flexion influenced KOOS Pain and Function in Activities of Daily Living (p<0.05). Both, tibial sagittal alignment and femoro-tibial gaps at 80°–90° knee flexion were found to correlate with SF-12 Physical Status and presence of post-operative pain (p<0.01). ‘Excellent’ clinical outcomes were reported by those patients who, on average, had the femur placed in neutral alignment in the coronal and horizontal planes (0.2°±1.5 and 0.6°±1.4 respectively) as well as avoided excessive flexion in the sagittal plane (3.7°±3.2). When considering the tibia, better results were reported by patients with the tibial component placed in slight external rotation (2.2°±1.7), varus coronal alignment (1.5°±1.7) and no more than 5° of posterior slope (5.0°±1.0). Regarding femoro-tibial gaps, ‘excellent’ clinical outcomes were reported by patients who were slightly loose between 20°–30° and 80°–90° of knee flexion. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 309 patients with medial robotic assisted UKA were contacted with at a mean 3-years. The overall survivorship was found to be 99%, with tibial component failure as the most common reason for UKA revision. The significant difference between pre- and post-operative clinical scores highlights the efficacy of robotic assisted UKA in restoring knee function and relieving pain. Differences in components’ positioning and soft-tissue tensioning demonstrated significant correlation with post-operative clinical outcomes


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 907 - 915
1 Sep 2024
Ross M Zhou Y English M Sharplin P Hirner M

Aims

Knee osteoarthritis (OA) is characterized by a chronic inflammatory process involving multiple cytokine pathways, leading to articular cartilage degeneration. Intra-articular therapies using pharmaceutical or autologous anti-inflammatory factors offer potential non-surgical treatment options. Autologous protein solution (APS) is one such product that uses the patient’s blood to produce a concentrate of cells and anti-inflammatory cytokines. This study evaluated the effect of a specific APS intra-articular injection (nSTRIDE) on patient-reported outcome measures compared to saline in moderate knee OA.

Methods

A parallel, double-blinded, placebo-controlled randomized controlled trial was conducted, where patients with unilateral moderate knee OA (Kellgren-Lawrence grade 2 or 3) received either nSTRIDE or saline (placebo) injection to their symptomatic knee. The primary outcome was the difference in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score at 12 months post-intervention. Secondary outcomes included WOMAC component scores, Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (VAS) scores at all follow-up timepoints (three, six, and 12 months).


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 657 - 662
1 Jun 2022
Barlow T Coco V Shivji F Grassi A Asplin L Thompson P Metcalfe A Zaffagnini S Spalding T

Aims

Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival.

Methods

We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 875 - 883
1 Jul 2022
Mills K Wymenga AB van Hellemondt GG Heesterbeek PJC

Aims

Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA).

Methods

This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction).


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs.

Methods

In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m2 (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1016 - 1024
1 Aug 2020
Hasan S van Hamersveld KT Marang-van de Mheen PJ Kaptein BL Nelissen RGHH Toksvig-Larsen S

Aims

Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. This study compares the migration of cementless, 3D-printed TKA to cemented TKA of a similar design up to two years of follow-up using radiostereometric analysis (RSA) known for its ability to predict aseptic loosening.

Methods

A total of 72 patients were randomized to either cementless 3D-printed or a cemented cruciate retaining TKA. RSA and clinical scores were evaluated at baseline and postoperatively at three, 12, and 24 months. A mixed model was used to analyze the repeated measurements.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 124 - 128
1 Nov 2013
Hofmann AA Shaeffer JF McCandless JB Magee TH

Isolated patellofemoral arthritis is a common condition and there are varying opinions on the most effective treatments. Non-operative and operative treatments have failed to demonstrate effective long-term treatment for those in an advanced stage of the condition. Newer designs and increased technology in patellofemoral replacement (PFR) have produced more consistent outcomes. This has led to a renewed enthusiasm for this procedure. Newer PFR prostheses have addressed the patellar maltracking issues plaguing some of the older designs. Short-term results with contemporary prostheses and new technology are described here.

Cite this article: Bone Joint J 2013;95-B, Supple A:124–8.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 857 - 862
1 Jul 2014
Abdel MP Oussedik S Parratte S Lustig S Haddad FS

Substantial healthcare resources have been devoted to computer navigation and patient-specific instrumentation systems that improve the reproducibility with which neutral mechanical alignment can be achieved following total knee replacement (TKR). This choice of alignment is based on the long-held tenet that the alignment of the limb post-operatively should be within 3° of a neutral mechanical axis. Several recent studies have demonstrated no significant difference in survivorship when comparing well aligned versus malaligned TKRs. Our aim was to review the anatomical alignment of the knee, the historical and contemporary data on a neutral mechanical axis in TKR, and the feasibility of kinematically-aligned TKRs.

Review of the literature suggests that a neutral mechanical axis remains the optimal guide to alignment.

Cite this article: Bone Joint J 2014;96-B:857–62.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1649 - 1654
1 Dec 2012
Pengas IP Assiotis A Nash W Hatcher J Banks J McNicholas MJ

We continued a prospective longitudinal follow-up study of 53 remaining patients who underwent open total meniscectomy as adolescents and who at that time had no other intra-articular pathology of the knee. Their clinical, radiological and patient-reported outcomes are described at a mean follow-up of 40 years (33 to 50). The cohort of patients who had undergone radiological evaluation previously after 30 years were invited for clinical examination, radiological evaluation and review using two patient-reported outcome measures.

A total of seven patients (13.2%) had already undergone total knee replacement at the time of follow-up. A significant difference was observed between the operated and non-operated knee in terms of range of movement and osteoarthritis of the tibiofemoral joint, indicating a greater than fourfold relative risk of osteoarthritis at 40 years post-operatively. All patients were symptomatic as defined by the Knee Injury and Osteoarthritis Outcome Score.

This study represents the longest follow-up to date and it can be concluded that meniscectomy leads to symptomatic osteoarthritis of the knee later in life, with a resultant 132-fold increase in the rate of total knee replacement in comparison to their geographical and age-matched peers.


Bone & Joint Research
Vol. 1, Issue 12 | Pages 315 - 323
1 Dec 2012
Molt M Ljung P Toksvig-Larsen S

Objectives

The objective of this study was to compare the early migration characteristics and functional outcome of the Triathlon cemented knee prosthesis with its predecessor, the Duracon cemented knee prosthesis (both Stryker).

Methods

A total 60 patients were prospectively randomised and tibial component migration was measured by radiostereometric analysis (RSA) at three months, one year and two years; clinical outcome was measured by the American Knee Society score and the Knee Osteoarthritis and Injury Outcome Score.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 484 - 489
1 Apr 2011
Charalambous CP Abiddin Z Mills SP Rogers S Sutton P Parkinson R

The low contact stress patellofemoral replacement consists of a trochlear component and a modular patellar component which has a metal-backed mobile polyethylene bearing. We present the early results of the use of this prosthesis for established isolated patellofemoral arthritis in 51 consecutive patellofemoral replacements in 35 patients. The mean follow-up was 25 months (5 to 60). The estimated survival rate at three years was 63% (95% confidence interval 47 to 80) with revision as the endpoint and 46% (95% confidence interval 30 to 63) with revision and ongoing moderate or severe pain as the endpoint.

The early results of the use of the low contact stress patellofemoral replacement are disappointing with a high rate of revision. We cannot therefore recommend its use.