Aims. This study addressed two questions: first, does surgical correction of an idiopathic scoliosis increase the volume of the rib cage, and second, is it possible to evaluate the change in lung function after corrective surgery for adolescent idiopathic scoliosis (AIS) using biplanar radiographs of the ribcage with
Purpose of the study: Leg length discrepancy after THA is a common complication and source of recurrent complaints from patients. To date, no reliable and reproducible technique has come forward to enable accurate quantification of all radiological parameters of the lower limb. Nevertheless, preoperative planning for hip arthroplasty requires knowledge of many limb parameters, in particularly leg length discrepancy, femoral offset, or the head-neck angle. The most widely used method is to use the 2D radiographs. The EOS system uses two digitalised 2D images taken orthogonally in a weight-bearing position to enable
Personalized three-dimensional (3D) femoral geometry is a great aid in the surgical planning. X-ray image is still essential to diagnose and plan surgery in total hip replacement due to its lower cost and lower dose of radiation than computer tomography (CT). The purpose of the current study is to improve
Aims. The aim of this study was to establish a reliable method for producing
Detailed preoperative planning is essential for open reduction and internal fixation of acetabular fractures if a successful outcome is to be achieved. Decisions such as patient positioning, approach, reduction techniques and implant positioning are greatly influenced by fracture pattern and displacement. These fractures are frequently complex and a thorough understanding of their 3-Dimensional (3D) form is necessary for pre-operative decision making. A combination of biplanar x-rays, 2 Dimensional CT scans (Axial, Sagittal and Coronal multi-plane reformats) and, more recently,
Purpose: Partial epiphysiodesis of the growth plate due to physeal aggression is a common problem in paediatric patients. Surgical management requires precise imaging. We recall other imaging techniques currently employed and describe a novel method for studying the characteristic features of epiphysiodesis bridges of the growth plate: 3D-magnetic resonance imaging (3D-MRI). Material and methods: We analysed retrospectively MRI series of 27 epiphysiodesis bridges in 23 children (ten boys and thirteen girls) aged 11.3 years (range 2.5 – 15). We recorded information concerning the cause of the physeal aggression, the joint involved, the type of bony bridge (Ogden classification), the clinical deformation, and the proposed treatment. The 27 bridges were studied on coronal MRI acquired with echo-gradient and fat suppression sequences. Data were processed with a manual
Open reduction and internal fixation of acetabular fractures demands detailed preoperative planning, and given their frequent complexity, a thorough understanding of their three-dimensional (3D) form is necessary. This study aims to assess if the use of dynamic 3D models will improve preoperative planning of acetabular fractures. In this study, three experienced pelvic trauma surgeons were provided with computer based dynamic 3D models in addition to preoperative radiographs, CT scans and static
Anterior shoulder instability is associated with osseous defects of the glenoid and/or humeral head (Hill-Sachs lesions). These defects can contribute to the pathology of instability by engaging together. There is a need to continue to develop methods to preoperatively identify engaging Hill-Sachs lesions for determining appropriate surgical management. The objective was to created a working moveable 3D CT model that allows the user to move the shoulder joint into various positions to assess the relationship between the Hill-Sachs lesion and the anterior glenoid rim. This technique was applied to a cohort series of 14 patients with recurrent anterior dislocation: 4 patients had undergone osteoarticular allografting of Hill-Sachs lesions and 10 control patients had undergone CT scanning to quantify bone loss but had no treatment to address bony pathology. A biomechanical analysis was performed to rotate each 3D model using local coordinate systems through a functional range using an open-source 3D animation program, Blender (Amsterdam, Netherlands). A Hill-Sachs lesion was considered “dynamically” engaging if the angle between the lesion's long axis and anterior glenoid was parallel. In the classical vulnerable position of the shoulder (abduction=90, external rotation=0–135), none of the Hill-Sachs lesions aligned with the anterior glenoid in any of our patients (Figure 1). Therefore, we considered there to be a “low risk” of engagement in these critical positions, as the non-parallel orientation represents a lack of true articular arc mismatch and is unlikely to produce joint instability. We then expanded our search and simulated shoulder positions throughout a physiological range of motion for all groups and found that 100% of the allograft patients and 70% of the controls had positions producing alignment and were “high risk” of engagement (p = 0.18) (Table 1). We also found that the allograft group had a greater number of positions that would engage (mean 4 ± 1 positions of engagement) compared to our controls (mean 2 ± 2 positions of engagement, p = 0.06). We developed a 3D animated paradigm to dynamically and non-invasively visualize a patient's anatomy and determine the clinical significance of a Hill-Sachs lesion using open source software and CT images. The technique demonstrated in this series of patients showed multiple shoulder positions that align the Hill-Sachs and glenoid axes that do not necessarily meet the traditional definition of engagement. Identifying all shoulder positions at risk of “engaging”, in a broader physiological range, may have critical implications towards selecting the appropriate surgical management of bony defects. We do not claim to doubt the classic conceptual definition of engagement, but we merely introduce a technique that accounts for the dynamic component of shoulder motion, and in doing so, avoid limitations of a static criteria assumed traditional definition (like size and location of lesion). Further investigations are planned and will help to further validate the clinical utility of this method. For any figures or tables, please contact the authors directly.
Aims. The aim of this study was to analyse the effect of altered viewing
perspectives on the measurement of the glenopolar angle (GPA) and
the differences between these measurements made on 3D CT reconstructions
and anteroposterior (AP) scapular view radiographs. . Materials and Methods. The influence of the viewing perspective on the GPA was assessed,
as were the differences in the measurements of the GPA between 3D
CT reconstructions and AP scapular view radiographs in 68 cadaveric
scapulae. Results. The median GPA in
In clinical routine surgeons depend largely on 2D x-ray radiographs and their experience to plan and evaluate surgical interventions around the knee joint. Numerous studies have shown that pure 2D x-ray radiography based measurements are not accurate due to the error in determining accurate radiography magnification and the projection characteristics of 2D radiographs. Using 2D x-ray radiographs to plan 3D knee joint surgery may lead to component misalignment in Total Knee Arthroplasty (TKA) or to over- or under-correction of the mechanical axis in Lower Extremity Osteotomy (LEO). Recently we developed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation system called “iLeg” for TKA or LEO. Based on a patented X-ray image calibration cage and a unique 2D–3D reconstruction technique, iLeg can generate accurate patient-specific 3D models of a complete lower extremity from two standing X-rays for true 3D planning and evaluation of surgical interventions at the knee joint. The goal of this study is to validate the accuracy of this newly developed system using digitally reconstructed radiographs (DRRs) generated from CT data of cadavers. CT data of 12 cadavers (24 legs) were used in the study. For each leg, two DRRs, one from the antero-posterior (AP) direction and the other from the later-medial (LM) direction, were generated following clinical requirements and used as the input to the iLeg software. The 2D–3D reconstruction was then done by non-rigidly matching statistical shape models (SSMs) of both femur and tibia to the DRRs (seee Fig. 1). In order to evaluate the 2D–3D reconstruction accuracy, we conducted a semi-automatic segmentation of all CT data using the commercial software Amira (FEI Corporate, Oregon, USA). The reconstructed surface models of each leg were then compared with the surface models segmented from the associated CT data. Since the DRRs were generated from the associated CT data, the surface models were reconstructed in the local coordinate system of the CT data. Thus, we can directly compare the reconstructed surface models with the surface models segmented from the associated CT data, which we took as the ground truth. Again, we used the software Amira to compute distances from each vertex on the reconstructed surface models to the associated ground truth models.Introduction
Methods
Recently we developed a personalised X-ray reconstruction-based planning and post-operative treatment evaluation system called iLeg for total knee arthroplasty or lower extremity osteotomy. Based on a patented X-ray image calibration cage and a unique 2D-3D reconstruction technique, iLeg can generate accurate patient-specific 3D models of a complete lower extremity from two standing X-rays for true 3D planning and evaluation of surgical interventions at the knee joint. The goal of this study is to validate the accuracy of this newly developed system using digitally reconstructed radiographs (DRRs) generated from CT data of 12 cadavers (24 legs). Our experimental results demonstrated an overall reconstruction accuracy of 1.3±0.2mm.
- scapulas can be classified into two groups regarding the angle between the glenoid surface and the upper posterior column of the scapula with significant differences between them. - two different lengths of the neck of the inferior glenoid body have also been differentiated in the anterior as well as in the posterior faces of the scapula. - the base of the coracoid process is not in line with the posterior column of the scapula. - three-dimensional computed tomography of the scapula constitutes and important tool when planning reversed prostheses implantation.
Pedicle-lengthening osteotomy is a novel surgery for lumbar spinal stenosis (LSS), which achieves substantial enlargement of the spinal canal by expansion of the bilateral pedicle osteotomy sites. Few studies have evaluated the impact of this new surgery on spinal canal volume (SCV) and neural foramen dimension (NFD) in three different types of LSS patients. CT scans were performed on 36 LSS patients (12 central canal stenosis (CCS), 12 lateral recess stenosis (LRS), and 12 foraminal stenosis (FS)) at L4-L5, and on 12 normal (control) subjects. Mimics 14.01 workstation was used to reconstruct 3D models of the L4-L5 vertebrae and discs. SCV and NFD were measured after 1 mm, 2 mm, 3 mm, 4 mm, or 5 mm pedicle-lengthening osteotomies at L4 and/or L5. One-way analysis of variance was used to examine between-group differences.Objectives
Methods
Accurate reconstruction of the knee pose from two X-Ray images will allow the study pre-operative kinematics (for custom prosthesis design) and the post-operative evaluation of the intervention. We used a SSM of the distal femur, based on 24 MRI datasets, from which the mean model and its modes of variation were defined. On the SSM, N landmarks in predefined positions were defined. The user identifies the same landmarks on two X-ray projections. Back-projecting the X-ray from the identified landmarks pixel to the corresponding source, each landmark position in the 3D space is reconstructed and the mean model pose initialised with a corresponding points registration. The silhouette of the SSM is projected on each X-ray image, which is automatically segmented in order to define the bone contours. With a Robust Point Matching algorithm based on Thin Plate Splines the projected silhouette points are deformed to better approximate the contour. For each contour point, the associated silhouette point is computed. We back-projected the ray from each contour point to the source and find on each ray the point with minimum distance to the silhouette. The cost function is the squared sum of the distances for both images. After a first optimisation of the pose, we perform a shape optimisation to find the correct weights for the SSM. To evaluate our algorithm, we used two Digitally Reconstructed Radiographs (DRR) created as projections at 90° from a CT dataset. The CT based model was reconstructed and the landmarks were defined on it with a rigid registration of the SSM. In order to validate the robustness of our reconstruction method, a random uniform noise distribution (0–50 mm on each direction) was added on each landmark. The reconstruction accuracy was measured as the distance between each reconstructed landmark and the ground truth defined on the CT. Results show that the population of the errors for the noise levels from 0 to 30 is similar: only the population with 50 mm noise is significantly different from the results obtained with other noise levels. We can conclude that with a noise level below 50 mm the algorithm is able to return the correct pose of the femur, while with higher noise the initial distribution of the landmarks in the 3D space prevents the correct outcome of the algorithm. The user should select the landmarks within a range of 50 mm on the 3D representation, that is half the dimension of the bounding box containing the model. We can assume that in the real case it will be more difficult to select the proper position of the landmarks, but our method proved to be robust even with misplaced landmarks.
Limb length disparity is a frequent complication after hip surgery inducing many surgeon-patients conflicts. To date no study has been able to precisely quantify such limb length disparity. EOS® system, currently validated to measure lower limb parameters, allows from two bi-dimensional numerical orthogonal radiographies in standing position to obtain a tri-dimensional reconstruction of lower limbs. A computerized system achieves the parameters calculation. The aim of this study is to precisely measure the limb length disparities and the other hip parameters following total hip arthroplasty surgical procedure, by using a standard X-rays and using EOS® three-dimensional reconstructions. Twenty-eight patients programmed for total hip arthroplasty have been included (i.e. thirty lower limbs). Two independent performers have carried out twice the measures either on standard X-rays and using three-dimensional reconstructions of the lower limb disparities prior and after the surgical procedure. The inter and intra-observer reproducibility for the measure of the lower limb disparities have been of the EOS® measures have been respectively of 0.854 and 0.865 and for the standard X-rays of 0.717 and 0.726. Mean length disparity observed was before Total Hip Arthroplasty of −0.328 cm (0.705; −1.266/0.530) and was of 0.088 mm (1.326; −1.635/0.632) after. We are able to decrease the lower limbs disparity in 69.1% and for the average of 0,416cm. Using EOS® system has allowed assessing with greater precision the possibility to restore equal lower limb length. This assessment has permitted introducing a new planning procedure including EOS® imaging associated to the fusion of the prosthetic tri-dimensional image in order to achieve adequate lower limb length.
Aims. The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. Methods. This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven observers reviewed preoperative radiographs and CT scans twice, with a minimum four-week interval. Radiographs and CT scans were reviewed separately. Inter- and intraobserver reliability were calculated using Fleiss and Cohen kappa coefficients. The Landis and Koch criteria were used to interpret the strength of the kappa values. Validity was assessed by calculating the percentage agreement against intraoperative findings. Results. Of the 48 patients, three (6%) had type A injury, 11 (23%) type B, 16 (33%) type B+, 16 (33%) Type C, two (4%) type D+, and none had a type D injury. All 48 patients had anteroposterior (AP) and lateral radiographs, 44 had 2D CT scans, and 39 had
Aims. Successful cell therapy in hip osteonecrosis (ON) may help to avoid ON progression or total hip arthroplasty (THA), but the achieved bone regeneration is unclear. The aim of this study was to evaluate amount and location of bone regeneration obtained after surgical injection of expanded autologous mesenchymal stromal cells from the bone marrow (BM-hMSCs). Methods. A total of 20 patients with small and medium-size symptomatic stage II femoral head ON treated with 140 million BM-hMSCs through percutaneous forage in the EudraCT 2012-002010-39 clinical trial were retrospectively evaluated through preoperative and postoperative (three and 12 months) MRI. Then,
Aims. Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT
Aims. The morphology of medial malleolar fracture is highly variable and difficult to characterize without