To review the results of the treatment of pilon fracture with percutaneous internal fixation and extrarticular ring fixation in neutralization, twenty-two fractures in twenty-one patients were included in the study. The mean follow-up time was 5.3 years. Five fractures were classified Ruedi-Algower type I, six were Ruedi-Algower type II and eleven Ruedi-Algower type III. Six were open fractures (3 Gustilo type III) and there were 19 associated fibular fractures (five were internally fIxed). Thirteen fractures (60%) were associated with metaphysealdiaphyseal dissociation (MDD). The majority of fractures were high energy (18 out of 22). General health outcome was assessed with the use of the SF-36 and functional outcome was evaluated with AOFAS score and Bone’s criteria. The average AOFAS score for the study population was 79.4. The AOFAS scores decreased as the severity of the fracture increases and these differences were statistically significant between the Ruedi-Algower types I and III. The pilon fractures population scored lower in all SF-36 categories but mental health and energy and vitality when compared to an age matched population but statistically significant differences were only found in the categories of physical function and limitation due to health problems. 65% achieved excellent or good results according to Bone’s criteria. No significant differences were found in the union times in the MDD group (253 days) when compared to the fractures with no MDD (224 days), but this can be due to the high incidence of autograft in the MDD group (7 out of 13). All patients achieved full weight bearing at 6 weeks. Fourteen patients had superficial pin site infections (one needed screw removal) that settled with oral antibiotics. There was one case of non-union and two varus heels.
To review the results of limb lengthening and deformity correction in fibular hemimelia, fifty-five patients with fibular hemimelia underwent limb reconstruction at Sheffield Children’s Hospital. According to Achter-man and Kalamchi classification, twenty-six were classified as Type IA, six as Type IB and twenty-three as Type II fibular hemimelia. All patients had at least some shortening of ipsilateral femur but forty-nine had sig-nificant femoral deficiency. Lengthening of tibia and in significant cases femur was done using De Bastiani or Vilarrubias or Ilizarov methods. Ankle valgus and heel valgus were corrected through osteotomies either in the supramalleolar region or heel. Equinus was corrected by lengthening of tendoachelis with posterior soft tissue release and in severe cases using Ilizarov technique. The average length gained was 4.2 cm (range 1 to 8) and the mean percentage of length increase was 15.82 (range 4.2 to 32.4). Mean bone healing index was 54.23 days/cm. Significant complications included knee subluxation, transient common paroneal nerve palsy, and recurrence of equinus and valgus deformity of foot. Overall alignment and ambulation improved in all patients. Knee stiffness due to cruciate deficient subluxations needed prolonged rehabilitation. Presence of 3-ray foot gives a better functional result and cosmetic acceptance by patients. The Ilizarov frame has the advantage to cross joints and lengthen at the metaphysis. Limb reconstruction in fibular hemimelia using limb lengthening and deformity correction techniques improve functional status of involved lower limb.
We report a series of sixty corrections in fifty-five adult patients performed from 1989 to 2001 for complex deformities of the foot and ankle, using circular external fixation, with a mean follow up of 4.4 years. We studied the aetiology, pathophysiology of injury, clinical and radiological evaluation, and the method and outcome of treatment. The patients mean age was 37 years (range 16–65). 37 male. 18 females. 44 deformities were sequel of severe lower limb trauma; the others were due to neurological, congenital and iatrogenic causes. 38 patients had associated proximal pathology including non-union, malunion, shortening and deformities. This required simultaneous correction. In most patients, conventional surgery had failed to achieve correction and many of them were considered for amputation. The aim of surgery was correction of deformity in forty-two occasions and correction of deformity with ankle fusion in eighteen occasions. For each patient, specific treatment goals were delineated that were realistically achievable. Initial complete correction was achieved in fifty-two patients; there was recurrence of the deformity in fourteen. Forty patients needed corrective osteotomies (16 ankles, 24 tibia and fibula). The results were classified as excellent in six patients, good in thirty-five patients, fair in eight patients, poor in six patients, five of whom had a below-knee amputation. Complications were minor and all resolved with appropriate therapy.
To review the results of reconstruction of pseudoar-throsis and/or significant varus with retroversion of proximal femur in congenital longitudinal lower limb deficiencies, twenty-three of ninety-five patients with lower limb deficiencies underwent proximal femoral reconstruction at the Sheffield Children’s Hospital. All twenty-three underwent valgus derotation osteotomies to correct coxa vara and retroversion of femur. Seven patients also had pseudoarthrosis of the neck of femur. Three of these were treated with valgus derotation osteotomy and cancellous bone grafting, two with fibular strut grafts, one King’s procedure and one with excision of fibrous tissue and valgus derotation osteotomy. A variety of internal fixation devices and external fixator were used. Seventeen of the twenty-three patients had valgus osteotomies repeated more than once (average 2.3) for recurrence of varus deformity. Average initial neck-shaft angle was 72 degrees, which improved to an average of 115 degrees after reconstruction. All seven patients with pseudoarthroses underwent multiple procedures (average 3.3) to achieve union. Cancellous bone grafting was repeated twice in two patients to achieve union but all three with cancellous bone grafting underwent repeat osteotomies to correct residual varus. Two patients achieved union after fibu-lar strut grafting. One patient, who underwent excision of pseudoarthrosis, achieved union but had to undergo further valgus osteotomy. No particular advantage of any one-fixation device over the others was noted in achieving correction. Early axis correction using valgus derotation oste-otomy is important in limb reconstruction when there is significant coxa vara and retroversion, although recurrence may require repeated osteotomies. Pseudoarthro-ses needed more aggressive surgery to achieve union.
We changed our pin tract care practice from 1996. We had a significant decrease in pin tract infections since then (p<
0.0001). We also found that using Ilizarov wires had significantly less infections than with half pins used with monolateral fixators (p<
0.0001; linear trend, p= 0.0338). There were 48 patients that required hospital admissions for IV antibiotics. and of these 10 patients required debridement. There were no residual long lasting infections or chronic osteomyelitis.
Fine-wire fixator systems have been used successfully for the treatment of fractures, malunions and for limb lengthening for many years. There has been much research investigating the biomechanical properties of these systems but this has been almost entirely centred on the mechanical properties of the fixator as a whole. Our knowledge of the interactions occurring at the interface between wire and bone remains sparse. To this end we devised an experimental model to analyse the distribution of pressure in cancellous bone surrounding a tensioned wire under loading conditions. The Sawbones cancellous bone material (type 1522-11) was cut into 65x30x40 mm blocks. A 2 mm olive wire was inserted into each block, parallel to the surface and along the 65 mm dimension. The distance from the wire to the surface was variable, from 0.5mm to 5mm in a 0.5mm increment. The wire was mounted on a 150 mm ring and tensioned to 1200 N against a load cell. The ring was rigidly mounted on a material testing machine and a second bone block was incorporated into the testing machine crosshead with a universal joint. Three grades of pressure-sensitive films (Low, Superlow and Ultralow) were sandwiched in turn between the testing block and cross head. The force applied was 175 N for 5 s. The developed film was scanned into a computer and a Matlab program was developed to analyse the pressure image. The results show three phases of pressure distribution. Very close to the wire there is a polar distribution of pressure that is, the pressure is concentrated towards the entry and exit points of the wire. At a depth of 1.5mm away from the wire the pressure becomes evenly distributed along the path of the wire in a beam-loading manner. At a distance of greater than 4mm from the wire there is even distribution of pressure throughout the bone. The peak pressures (6–8 MPa) were found closest to the wire. Most of the pressure measured was less than 1 MPa, which is less than the yield strength of cancellous bone (2–7 MPa, Li and Aspden, 1997). In contrast a similar analysis using threaded half pins under the same conditions showed far higher peak pressures (20 MPa), which were present deeper in the bone specimen. The pressure was concentrated toward the pin entry site and was not well distributed throughout the pin-bone interface. These results allow us to explain why ring fixators are superior to half pin fixators when used in metaphyseal bone.
The average follow up was 25.7 months. For logistic regression analysis the patients were binary coded into two groups: those with a good outcome (BHI<
45 days/cm) and those with a poor outcome (BHI>
45 days/cm). Various factors which may influence the out come were then analysed.
11 patients had foot plate extension, and 5 had cross knee extension for unstable knee. 10 patients had bifocal osteotomy, and 8 patients had spontaneous SLR for femoral lengthening or correction. The mean bone healing index was 49 days/cm (20–95). The mean maximum correction in any one plane was 150 (3–40), the site of the osteotomy was mainly metaphyseal at an average of 25% of the tibial length. There were 5 grade II complications, 9 grades I complications and one type III complication. Thirteen patients had grade I pin site infection, three had grade II and 12 had no pin site problems. A moderately strong relationship was identified between the BHI and a number of variables such as complications, maximum correction and pin site infection grade. The analysis of the factors which may influence the BHI suggested a correlation between increasing angular correction and poor out come BHI.
The average shortening was 34.8 mm (8–60), the average maximum deformity in any one plane was 19.8 degree (6–40). All the patient underwent corrective surgery and lengthening, five patients had Sheffield Ring Fixator, two had Limb Reconstruction System and one had percutaneous osteotomy on Albizzia nail. The patients who underwent SRF and LRS stayed in the frame for an average 258 days (150–435) The residual leg length discrepancy was 5.5 mm (0–12). There was three grade one complications, three grade two complications, and one patient had grade IV complication following compartment syndrome. Four patients had grade two pin site infection and three patients had grade one.
We present a series of 88 non-unions in which non-union, infection, bony alignment and length were addressed simultaneously, by using the Sheffield Ring Fixator. The mean follow up was 50 months (range 6–110) after union, which was achieved in 90.5% of the patients. The mean deformity correction was 16.80 (range 60–320), and mean length gain was 12.5 mm (range 2–40 mm). Smoking and infection had a statistical significant association with the time of healing, as healing of the non-union in over 18 months was more common in smoker and patients with infected non-union. There was no statistical difference between the functional score (SF-36) between these patients and normal population, at a follow up of minimum 2 years, but that was significant between pre operative and less than one year follow up on one side, and more than 2 years follow up on the other.
Acetabulum: Dysplastic/Non-dysplastic Ball (Head of femur): Present/Absent Cervix (Neck of femur): Pseudoarthrosis and neck-shaft angle Diaphysis of femur: Length/deformity Knee: Cruciates Fibula and Tibia: Length/deformity Ankle: Normal/Ball and socket/valgus Heel: Tarsal coalition/deformity Ray: Number of rays in the foot
We found the center of pressure of the ankle joint to be situated in the antero-medial quadrant, close to the center of the ankle joint. Distraction of the ankle joint by 5 mm eliminated any contact pressures at the ankle joint when the tibia was loaded up to 700N (one time body weight). When the joint was distracted by 10 mm no contact pressures were found in the ankle when loaded up to 1400N (two times body weight)
The center of pressure of the ankle joint is situated in the antero-medial quadrant. Distraction of 5 mm will eliminate ankle contact pressure up to one times body weight whereas distraction of 10 mm will eliminate contact pressures up to two times body weight.
The model developed in this study intended to look at linear distraction, i.e. lengthening.
To obtain a synthetic material with similar passive tensile properties to that measured in lengthened soft tissue To measure the effect of tensioned synthetic soft tissue on osteotomy motion and multi-planar stiffness during cyclic loading.
Soft tissue tension was simulated with the use of neoprene rubber sheeting, attached to the nylon rod by Jubilee clips, with a gap anteriorly or medially. Extensive tensile testing was performed to determine the visco-elastic behaviour of the rubber, which showed it to be consistent and reliable. Tension of a similar magnitude to lengthened muscle (35–125N) was achieved, and could be accurately predicted for certain distraction lengths. The stiffness of the frame was calculated from osteotomy motion with various distraction lengths both with the rubber attached and without.
These results highlight the importance of fixation techniques that rely on cancellous bone anchoring such as tensioned fine wire fixation in tibial plateau fractures.
Biomechanical studies involving all-wire and hybrid types of circular frame have shown that oblique tibial fractures remain unstable when they are loaded. We have assessed a range of techniques for enhancing the fixation of these fractures. Eight models were constructed using Sawbones tibiae and standard Sheffield ring fixators, to which six additional fixation techniques were applied sequentially. The major component of displacement was shear along the obliquity of the fracture. This was the most sensitive to any change in the method of fixation. All additional fixation systems were found to reduce shear movement significantly, the most effective being push-pull wires and arched wires with a three-hole bend. Less effective systems included an additional half pin and arched wires with a shallower arc. Angled pins were more effective at reducing shear than transverse pins. The choice of additional fixation should be made after consideration of both the amount of stability required and the practicalities of applying the method to a particular fracture.
At Sheffield Children’s Hospital 40 children with leg length discrepancies (caused variously by sepsis, trauma, hemihypertrophy, congenital longitudinal deficiencies) were assessed using three clinical methods: measuring blocks in the standing erect position, supine measurement from the anterior superior iliac spine to the medial malleolus, and prone measurement with the knees flexed, which allowed separate measurement of femoral and tibial discrepancies. All were then subjected to comparative CT scanogram. The mean age of the 24 boys and 16 girls was 10 years (5 to 16). Children with abnormal pelvic architecture or a fixed pelvic obliquity were excluded from the study. The mean clinical length discrepancy was 29 mm (0 to 80 mm). The mean CT scanogram measurement was 26.4 mm (0 to 75 mm). The mean difference between clinical measurements taken prone and CT scanogram measurements was only 3.6 mm (0 to 14). There was little difference in the accuracy of measuring femoral and tibial discrepancies clinically or by CT scanogram. The prone method of measurements is a useful adjunct to Staheli’s rotational profile in the prone position.
Data was analysed by calculating kappa coefþcients (95% CI)
We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI.
We describe our medium-term results for the management of chronic osteomyelitis in long bones using the Lautenbach procedure. Seventeen consecutive patients (18 segments) were treated prospectively. Osteomyelitis had been present for a mean of 12.5 years (1 to 31). A discharging sinus was present in all cases. Nine of the associated fractures had failed to unite and a further two needed correction of malunion. The Lautenbach procedure involves debridement, intramedullary reaming and the insertion of double-lumen tubes to establish both a local antibiotic delivery system and cavity analysis for volume and culture. The end-point of treatment is when the irrigate produces three consecutive clear cultures with improvement in the blood indices and obliteration of the cavity volume. The mean length of treatment was 27 days (14 to 48). One patient required a second procedure and another local debridement for recurrence of the infection. Two patients had Papineau grafting because of cortical defects. All the patients have subsequently remained free from infection. After treatment 11 had internal or external fixation for treatment of non- or malunion or a joint replacement, including two successful limb-lengthening procedures. Two further patients, while cured of infection, underwent amputation for other reasons. The mean length of follow-up was 75 months. This procedure allows precise control over the osteomyelitis until objective assessment suggests that infection has been cleared and the cavity obliterated. We recommend this procedure for long-standing complex cases in which basic techniques using debridement and antibiotics have failed.
Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome.
Aim: To assess the outcome of operative treatment of joint deformities using circular external fixators in arthrogryposis Materials and Methods: 16 cases were identified in 9 children, who underwent application of Ilizarov external fixation from 1989 to 2000 at the Sheffield Children’s Hospital for progressive correction of knee and foot deformities. This treatment modality was combined with either a soft tissue release, soft tissue distraction or a bony correction. Clinical outcomes were assessed, and comparisons were made between the different treatment modalities. Results: Three fixed flexion deformities of the knee treated with progressive correction and soft tissue distraction all achieved initial correction, but recurred some time after removal of fixators. Out of five club-feet treated with an Ilizarov frame with progressive soft tissue distraction alone, three deformities recurred despite long term splinting. The remaining eight club-foot deformities were treated with a bony procedure combined with gradual correction in the circular frame, and all corrections were maintained at follow up. The average treatment time in the fixator was 17 weeks (12–50 weeks), and the average follow up time was 36 months. Complications included 4 pin track sepses, 1 osteitis requiring a sequestrectomy, 1 transient neurapraxia and 1 fracture following removal of the fixator. Conclusion: The treatment of joint deformities in arthrogryposis remains challenging and difficult, and complications do occur. Combining the Ilizarov device with a bony procedure seems to have superior results and less recurrence of deformities than pure progressive soft tissue correction.
Objective: To review the hip subluxations or dislocations occurring during femoral lengthening in patients with congenital longitudinal lower limb deficiencies. Methods: Sixty-three patients with congenital longitudinal lower limb deficiencies underwent femoral lengthening using either De Bastiani, Villarubias or Ilizarov technique. Acetabular index, medial joint space, CE angle of Wiberg, acetabular angle of Sharp and neck-shaft angle were measured on anteroposterior radiographs of hip before, during and after lengthening. The Acetabulum was considered dysplastic when the Sharp angle was more than 45 degrees. Hip was considered to be subluxed when the medial joint space increased during lengthening. Results: During femoral lengthening, eleven hips sub-luxed as measured by the increase in medial joint space and one hip dislocated. All these hips had a preoperative acetabular index more than 25 degrees, CE angle less than 20 degrees and Sharp angle more than 45 degrees. The average neck-shaft angle was 75 degrees. Following subluxation, lengthening was stopped and the hips were reduced in hip spica after adductor and sartorius tenotomies. In one patient femoral shortening and acetabulo-plasty had to be done to reduce the subluxation. No case of avascular necrosis was noted. Conclusion: Hip subluxation during femoral lengthening of congenital longitudinal lower limb deficiencies tends to occur when the acetabular index is more than 25 degrees, Sharp angle is more than 45 degrees, CE angle is less than 20 degrees and when there is associated femoral coxa vara. Careful preoperative assessment is required, and if need be hip reconstruction prior to lengthening. Close monitoring during lengthening is recommended.
We have reviewed, retrospectively, all children with a lower limb deformity who underwent an acute correction and lengthening with a monolateral fixator between 1987 and 1996. The patients were all under the age of 19 years and had a minimum follow-up of eight months after removal of the fixator. A total of 41 children had 57 corrections and lengthening. Their mean age was 11.3 years (3.2 to 18.7) and there were 23 girls and 18 boys. The mean maximum correction in any one plane was 23° (7 to 45). In 41 bony segments (either femur or tibia) a uniplanar correction was made while various combinations were carried out in 16. The site of the osteotomy was predominantly diaphyseal, at a mean of 47% (17% to 73%) of the total bone length and the mean length gained was 6.4 cm (1.0 to 17.0). Univariate analysis identified a moderately strong relationship between the bone healing index (BHI), length gained, maximum correction and grade-II to grade-III complications. For logistic regression analysis the patients were binary coded into two groups; those with a good outcome (BHI ≤ 45 days/cm) and those with a poor outcome (BHI >
45 days/cm). Various factors which may influence the outcome were then analysed by calculating odds ratios with 95% confidence intervals. This analysis suggested a dose response between increasing angular correction and poor BHI which only reached statistical significance for corrections of larger magnitude. Longer lengthenings were associated with a better BHI while age and the actual bone lengthened had little effect. Those patients with a maximum angulatory correction of less than 30° in any one plane had an acceptable consolidation time with few major complications. The technique is suitable for femoral deformity and shortening, but should be used with care in the tibia since the risk of a compartment syndrome or neurapraxia is much greater.
We reviewed the outcome of 30 patients treated with an Ilizarov frame for resistant clubfoot deformity. Each patient was assessed using objective and subjective outcome measures. We used clinical examination, X-ray analysis, pedobarography and gait analysis and the Activities Scale for Kids questionnaire, developed and validated by The Hospital for Sick Children, Toronto, Canada. The average questionnaire score was 83. This suggested a good subjective outcome when compared to the average score of 38 achieved by children with untreated clubfoot. Patients were into 2 groups using this score. Patients scoring over 75 were considered to have a good outcome and those scoring less than 75 were considered to have a bad outcome. The objective results were then compared. We found no difference between the 2 groups using clinical examination and X-ray. Pedobarography showed lower pressures in the bad subjective group, in particular virtually no pressure was generated under the heel when walking. The pressure distribution also showed the bad group to have the pressure balance towards the front of the foot over the 5th metatarsal head. Gait analysis showed differences. The bad group had increased pelvic obliquity and increased pelvic movement suggesting an inefficient gait, increased hip abduction in swing, hyperextension of the knee on loading and decreased dorsiflexion of the ankle in swing when compared to the good group. Our conclusions were that subjectively this group of patients did well after surgical treatment using an Ilizarov frame. Clinical examination can show significant intra- and inter-observer error and X-ray is unreliable in children whose feet are congenitally deformed. Pedobarography and gait analysis seem to correlate better with subjective outcome. We know that a good foot is a functional foot and it may be that functional assessment is a more appropriate means of assessing results of treatment in these patients.
Increased incidence of complications has been reported when lengthening limbs with underlying bone disorders such as dysplasias and metabolic bone diseases. There is a paucity of literature on limb lengthening in Osteogenesis Imperfecta (OI), probably due to the concern that the bone containing abnormal collagen may not tolerate the external fixators for a long term and there may not be adequate regenerate formation from this abnormal bone. We performed limb lengthening and deformity correction of nine lower limb long bones in six children with OI. Four children were type I and two were type IV OI as per Sillence classification. The mean age was 14.7 years. All six children had lengthening for femoral shortening and three of them also had lengthening for tibial shortening on the same side. Angular deformities were corrected during lengthening. Five limb segments were treated using a monolateral external fixator and four limb segments were treated using an Ilizarov external fixator. In three children, previously inserted femoral intramedullary nails were left in situ during the course of femoral lengthening. The average lengthening achieved was 6.26 cm. Limb length discrepancies were corrected to within 1.5 cm of the length of the contralateral limb in five children. In one child with fixed pelvic obliquity and spinal scoliosis, functional leg length was achieved. The mean healing index was 33.25 days/cm of lengthening. Among the complications significant ones included, one deep infection, one fracture through the midshaft of the femur, and development of anterior angulation deformity after the removal of the fixator in one tibia. Abnormal bone of OI tolerated the external fixator throughout the period of lengthening without any incidence of migration of wires and screws through the soft bone when distraction forces were applied. The regenerate bone formed within the time that is normally expected in limb lengthening procedures performed for other conditions. We conclude that despite abnormal bone characteristics, limb reconstruction to correct limb length discrepancy and angular deformity can be done safely in children with OI.
The results of the first 100 consecutive patients treated in our tertiary referral non-union practice have been previously reported. The purpose of this report is to review this group together with a further 280 cases treated between 1991 and 2000. The principles of management remain the same, namely restoration of alignment, stabilisation and stimulation, however in the more recent cases increasing use of distraction, bone transport and bifocal techniques as well as single stage lengthening and correction of soft tissue contractures have been used to eliminate limb strength discrepancies. A total of 380 consecutive established non-unions treated between 1987 and 2000 were reviewed. Twenty-nine patients were lost to follow up (five deceased). There were 159 atrophic, 89 hypertrophic and 103 infected cases, with 319 cases as a result of trauma, and 32 cases as a consequence of planned surgery. The majority involved the tibia with 162 cases, followed by femoral non-unions with 51 cases and the remainder involving upper limb and smaller bones. At the time of review, 8 had abandoned treatment and 25 remained ununited. Twenty-one cases ended with amputations: 14 infected, 4 atrophic and 3 cases due to excessive pain following patients request. Union was achieved in 297 cases (85% overall union rate), representing 90% of atrophic, 89% of hypertrophic and 73% of the infected non-unions. A comparison is made between the first hundred previously unreported series of 280 cases. The overall union rates have improved from 80% to 85%, with an increase in union rates noted predominantly in the atrophic group. Infected cases remain more of a problem and challenging with lower healing rates. There was no statistical difference in union rates between smokers and non-smokers, but slower times to union and increased complication rates were noted in the heavy smokers (<
40/day). The non-union profiles, pathogenesis and change in treatment options are discussed.
Ankle arthrodesis is an accepted method of treatment for severe ankle pathology but no single method is universally successful. Compression is usually applied across the ankle joint and maintained with either internal or external fixation; both are associated with complications like infection, non-union, and pain.
We present our results and describe the surgical technique in managing 21 difficult cases using fine wire external frames in the salvage of severe ankle pathology. Nine cases were non-unions following internal fixation of distal tibial intra-articular fractures, seven were patients in whom two or three previous attempts at arthrodesis had been unsuccessful, and five patients had severe degenerative osteo-arthritis of the ankle joint.
A sound arthrodesis was achieved in 19 out of 21 cases giving a union rate of 90.4%. The median period of fixation was 21 weeks, followed by a mean period of cast immobilisation of eight weeks. All except three developed pin site inflammation. Using Mazur’s functional ankle score there were twelve good results, five fair, two poor and two failures.
A fusion rate of 90.4% was achieved using this method. We recommend it for the salvage of failed arthrodesis or severe fracture non-union, particularly in the presence of infection.
The aim was to study the use of limb reconstruction techniques in the management of Ollier’s Dysplasia over a period of 25 years. This was a retrospective review of case records and radiographs of patients who had lower limb reconstruction for deformity and limb length discrepancy. There were a total of 9 patients of whom 7 had reached maturity and four of these were still under follow up. The major aims of surgery were to correct lower limb length discrepancy and deformity. A total of twenty segments were operated upon. These were 11 femurs and 9 tibiae. In some segments repeated surgery was required. 41 index and 54 secondary procedures were necessary giving an average of 10.5 procedures per patient. The most common problems were difficulty in fixation in abnormal bone, premature consolidation reflecting the rich osteogenic potential and growth related recurrence of deformities and discrepancy. The mean length gained was 13.8 cms per patient. Healing of regenerate occurred with radiologically normal appearance even in chondro-dysplastic areas. All patients who had completed treatment had a satisfactory mechanical axis and the mean length discrepancy was 1.7 cms. Patients with Ollier’s dysplasia appear to respond well to limb reconstructive surgery. It is possible to correct severe limb length discrepancies and angular deformities. Surgeons should be aware of the possibility of premature healing and should consider faster lengthening rates of up to 1.5 mms per day. Distraction should begin early by day 5 or less. Immature patients should be warned about the possibility of recurrence of deformity and possible need for repeated surgery.
To evaluate the medium term results of the Lautenbach procedures for the treatment of chronic osteomyelitis [COM] in long bones. Cohort of 17 patients (18 segments) prospectively treated. Mean age 37 years. High-energy trauma effecting 8 tibia (6 open) &
9 femora (5 open). Duration of COM was mean 12. 5 years (1–31 years). Discharging sinus present in all. Lautenbach procedure comprises intramedullary reaming/debridement to 13 mm and establishment of local antibiotic delivery system, cavity analysis for volume and culture. The end point is 3 clear culture results of the irrigate, improvement in blood indices and reduction of cavity volume. Mean treatment time 27 days (14–48). Mean hospital stay 38 days. Two needed revision of Lautenbach procedure and one local debridement for recurrence of infection. 7 non-unions needed further fixation. 2 needed Papineau grafting and 3 had further limb lengthening procedures. Mean follow-up is 3. 3 years. 4 patients have been discharged, 1 awaiting THR. This procedure permits precise control over the osteomyelitis cavity until objective assessment suggests that infection has been cleared and cavity obliterated.
To evaluate the effects of smoking on fracture healing in a non-union population. A consecutive cohort of 104 patients with 107 non-unions managed by external fixation was reviewed. 75% were regular smokers compared to the regional average of 3 0%. 5 8 male and 20 female smokers, matched with the non-smoking group. Patients’ records and x-rays were evaluated; where information was missing patients were contacted by phone/post. Scoring was recorded from our own prospective database. The smokers underwent 2. 6 procedures per segment with a mean treatment time of 17. 43 months (4–64) compared to 1. 9 and 10. 9 (2. 5–24) respectively in non-smoking group. The total hospital stay was 66% greater in the smoking group (41. 12 vs 27. 4 days). 102 non-unions healed, including seven who required revision surgery, six of whom were smokers. In smoking group five went on to amputation and three had residual infection. The entire non-smoking group healed after primary surgery except a 70 years old lady who was converted to intramedullary nailing. The final assessment of the bony and functional results was performed by the method described by Paley and Catagni (JBJS 77A 1995).
When considered in the context of regional statistics for smoking there was a trend towards non-union in smokers [P<
0. 05]. When limb reconstruction treatment was compared between the two groups despite the low number of infected cases in the smoking group, the number of surgical procedures, duration of treatment and hospital stay were all increased. Failure, revision rate and residual infection were high in the smoking groups. We conclude that smoking adversely affects both primary fracture healing and non-union treatment.
To determine the Inter &
Intra-observer Agreement in Assessment &
Classification of Non-unions of fractures based on Radiological appearance. Medical records and X-rays of patients who attended the Limb Reconstruction Clinic (1987 to 2000) in a University Hospital for fracture non-union were studied. X-rays of one hundred adult patients with established non-union were selected by random sampling. Common denominators of various classification / assessment systems were selected for study. Observers were selected in 3 categories (2 in each): Senior Limb Reconstruction specialist, Consultant Musculoskeletal Radiologists, Senior trainees (Post-FRCS Orth). Data was analysed by calculating kappa coefficients (95% confidence intervals). Kappa measures between observer agreements having been corrected for chance. Radiologists were unable to comment on vascularity. (S= substantial, M= moderate, F= fair &
P= poor) It would appear that the agreement for classification of atrophic/hypertrophic non-union is good all round (both inter &
intra). Within this classification, radiologists showed better agreement than trainees whose results were better than Orthopaedic specialists. Agreement of healing potential &
infection was fair to poor only. Radiographic analysis of non-union remains poor indicating the need for further study to see whether identifiable features exist.
The aim of this study is to evaluate the efficiency of the Sheffield Ring Fixator (SRF) in the management of tibial deformity. Tibial deformity correction is challenging and requires an efficient system with strong bony fixation.Progressive correction is usually necessary due to the low compliance of the anatomical compartments. The SRF provides an effective solution, employing a combination of wire and screw fixation for metaphyseal corrections and all screw fixation for diaphyseal corrections. We reviewed a consecutive series of 50 patients with tibial deformity treated by progressive correction using the SRF between 1997 and 2000. The mean age was 33 years (range 18 to 65). Thirty nine cases were due to post-traumatic deformity and eleven as sequelae of childhood disease. Cases were analysed to ascertain the degree of deformity, treatment time, final outcome in terms of the accuracy of correction of deformity, and incidence of complications. All patients had significant angular deformity and 12 had a rotational deformity. 21 patients had clinically significant shortening. The mean deformities were: varus 10.5, valgus 13, posterior 11.8, anterior 20.6 (giving a mean oblique plane deformity of 24° ) rotation 17° and 26mm of shortening. Full correction was achieved in 45 of the 50 cases: Three patients had residual angular deformities of 5,7 and 10 degrees and two had residual shortening (15mm&
5mm). Satisfactory bone formation occurred in all cases. There were no significant complications. The mean correction time was dependent on whether or not lengthening had been performed (72 and 53 days respectively). From this study the correction time can be estimated as 2 days per degree plus an extra 0.5 days per degree for every centimetre of length to be gained. A knowledge of the efficiency of the system will enable estimation of treatment times to be made thereby facilitating the setting of goals for both patient and surgeon. Correction and total treatment times were satisfactory suggesting that the fixation system was both stable and yet sufficiently elastic to permit good bone healing. Even when the rotation translation systems were used prescribed movements led to satisfactory corrections suggesting few if any losses in the system. The SRF provides a strong and efficient system for the accurate and controlled correction of tibial deformities.
To assess the outcome of bicondylar tibial fractures, treated prospectively with fine wire fixation in the Limb Reconstruction Service. Twenty patients with mean age 56 years with bicondylar tibial plateau fractures, were treated at the author’s institution with fine wire fixation over a three-year period. Ten followed road traffic accidents and four followed high-energy falls; The remainder mainly in the elderly resulted from a simple fall. There were four Schatzeker type V, and sixteen type VI. Four were open fractures (Gustilo grade III); Seven patients sustained associated fractures at the same time. They were treated according to a prospective protocol and were followed up for an average of thirty months, (11 – 51). The protocol included CT Scan Guided planning, closed reduction if possible and percutaneous interfragmentary screw fixation to reconstruct the articular surface, under image intensifier control; The external fixator was applied in neutralization. Mobilization and full weight bearing was encouraged as early as possible Ten patients started full weight bearing between four and six weeks post operatively, in nine cases with other injuries weight bearing was delayed. All patients healed with an average time in the fixator of eighteen weeks, (9–25). Fifteen patients had a range of movement from Zero to at least 120 degrees flexion. Using Rasmussen’s functional and radiological scoring system, fifteen out of twenty scored good or excellent. Complications included deep vein thrombosis in one patient, loss of fracture reduction in three, superficial pin tract infection which resolved with local pin care and a short courses of antibiotic in five patients, there was no deep infection. The Sheffield hybrid external fixator is strong, permits early fracture recovery and weight bearing and may have significantly contributed to the high rate of good results in this group, of which more than 50% were over sixty years old. This technique is recommended for treatment of this difficult fracture.
Experience has shown that oblique fractures can be slow to heal and this has been attributed to excess shear at the fracture site. We routinely treat fractures with hybrid external fixation. In previous studies, olive wires placed through the fracture site reduced shear and this has improved healing times. When the fracture is oblique in the sagittal plane, anatomical constraints prevent the use of olive wires and a new solution is required. A sawbone tibia with a distal sagittal plane oblique fracture (70° obliquity) was stabilised with a Sheffield Hybrid Fixator. In a pilot study various methods of fixation were tested and six were chosen for further testing. Since the pull-out strength of threads in the plastic bone was poor, olive wires cut behind the olive were used as a mechanically equivalent model for the push-pull system. Seventy degree steerage pins could not be used so 25° pins were tested instead. Cyclic compressive forces (at 10mm/min) of up to 200N axially and in four off-axis positions were applied using a universal testing machine. Fracture site linear motion in three dimensions was measured using an inter-fragmentary motion device, sampled at 100Hz. A standard frame was tested before and after each adaptation and all six methods were applied sequentially to each model. The results suggest that: I) Arched wires are effective especially under greater bends, 2) Push-pull wires are effective and provide a minimally disruptive solution, 3) Steerage pins are effective especially at steeper obliquities but this may not always be practical, and 4) Placing a half pin in the distal fragment is beneficial but less effective than the use of 2 transverse half pins acting in a compression system (Hutson technique).
The validation of a new classification of the external fixator screw-bone interface. Screw loosening significantly affects the stability of an external fixator, however radiographs are normally taken to assess bone healing and not screw loosening. This study was performed to assess the inter and intra-observer reliability of radiographic features of external fixator screw loosening. Eight observers were shown plain radiographs of 120 external fixator bone-screw interfaces on two occasions, and were asked to grade the screws according to the following features.
Solid screw. Periosteal reaction around the screw. Area of lucency around the screw. Marginal corticalisation around the screw. Frank loss of position of the screw. The overall kappa value for this study was 0.29, with the component values ranging from 0.15 to 0.41. To determine if the reliability could be improved, two observers classified 192 digitised radiographs of external fixator screws. On the first occasion the radiographs were shown at a size, brightness and contrast equal to the original film. On the second occasion the radiographs were subjected to image enhancement and magnification. This showed improvement in all the kappa values, the overall value increasing to 0.39, with similar improvements in the component parts. Unfortunately no observations were made of loose screws, therefore, two observers were asked to classify 160 digitised images of screws which were selected with a bias in their outcome, to remain solid or become loose. The observers obtained a kappa value >
0.50 for loose screws. A classification system for the bone-screw interface is of value both in research and clinical practice. Despite the fact that standard radiographic views were used the classification system described shows satisfactory inter and intra-observer reliability and this improved when digital enhancement was applied.