Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model.Aims
Methods
Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.Aims
Methods
It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance.Aims
Methods
Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted total knee arthroplasty (RO TKA) and unicompartmental arthroplasty (RO UKA) versus conventional technique (CO TKA and UKA). Methods. This large-scale, single-institution study included patients of any age undergoing primary TKA (n = 1,375) or UKA (n = 337) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for post anaesthesia care unit (PACU) admission, anaesthesia type, readmission within 30 days, and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. Results. The median LOS in the RO TKA group was 76 hours (interquartile range (IQR) 54 to 104) versus 82.5 (IQR 58 to 127) in the CO TKA group (p < 0.001) and 54 hours (IQR 34 to 77) in the RO UKA versus 58 (IQR 35 to 81) in the CO UKA (p = 0.031). Discharge dispositions were comparable between the two groups. A higher percentage of patients undergoing CO TKA required PACU admission (8% vs 5.2%; p = 0.040). Conclusion. Our study showed that
The February 2023 Hip & Pelvis Roundup. 360. looks at: Total hip arthroplasty or internal fixation for hip fracture?; Significant deterioration in quality of life and increased frailty in patients waiting more than six months for total hip or knee arthroplasty: a cross-sectional multicentre study; Long-term cognitive trajectory after total joint arthroplasty; Costal cartilage grafting for a large osteochondral lesion of the femoral head; Foley catheters not a problem in the short term; Revision hips still a mortality burden?; How to position implants with a
The purposes of this study were to evaluate the accuracy and feasibility of a robotic preparation for acetabular metal augments in patients with developmental dysplasia of the hip (DDH). Mako
Introduction. Robotic-assisted hip arthroplasty helps acetabular preparation and implantation with the assistance of a
Introduction. Recent technological advancements have led to the introduction of robotic-assisted total knee arthroplasty to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy is not widely reported. The primary objective of this study is to determine the accuracy and precision of a cut block positioning
Introduction. Total knee arthroplasty (TKA) using conventional instrumentation has been shown to be a safe and effective way of treating end stage osteoarthritis by restoring function and alleviating pain. As robotic technology is developed to assist surgeons with intra-operative decision making such as joint balancing and component positioning, the safety of these advancements must be established. Furthermore, functional recovery and clinical outcomes should achieve comparable results to the gold standard of conventional instrumentation TKA. Methods. Eighty-seven subjects (89 knees) underwent
INTRODUCTION. Adult reconstructive orthopedic surgery in the United States is facing an imminent logjam due to the increasing divergence of the demand for services and the ability for the community to supply those services. In combination with several other factors, a perfect storm is brewing that may leave the system overtaxed and the patient population suffering from either a lack of treatment, or treatment by less qualified providers. A key component to improving the overall efficiency of surgical care is to introduce enabling technologies that can effectively increase the throughput while simultaneously improving the quality of care. One such enabling technology that has proven itself in many industries is robotics, which has recently been introduced in surgery with even more recent applications in orthopedic surgery. A surgeon interactive
With the approval of our institute, we reviewed all the robot-assisted hip revision during October 2019 and August 2021. MAKO joint arthroplasty system was used to perform the hip revision surgery. Seventy-one robot-assisted hip revision cases were included. Cup revisions were carried out in 68 patients while stem revisions were also carried out in 68 patients. Three types of registration techniques (extra acetabular bone surface based, liner based, metal shell based or cage surface based) on the acetabular side. The extra acetabular bone surface was the commonest used for registration (48/70, 68.6%, mean accuracy 0.37mm), followed by liner surface (11/70, 15.7%, mean accuracy 0.36mm), acetabulum cup (10/70, 14.3%, mean accuracy 0.37mm), and cage surface (1/70, 1.4%, accuracy 0.40mm). We succeeded cup registration and
Abstract. Objectives. Dual mobility (DM) hip implants whereby the polyethylene liner is “free-floating” are being used increasingly clinically. The motion of the liner is not well understood and this may provide insight into failure mechanisms; however, there are no published methods on tracking liner motion while testing under clinically relevant conditions. The aim was to develop and evaluate a bespoke inertial tracking system for DM implants that could operate submerged in lubricant without line-of-sight and provide 3D orientation information. Methods. Trackers (n=5) adhered to DM liners were evaluated using a
INTRODUCTION. Total hip arthroplasty (THA) is regarded as one of the most successful surgeries in medicine. However, recent studies have revealed that ideal acetabular cup implantation is achieved less frequently than previously thought, as little as 50% of the time. It is well known that malalignment of the acetabular component in THA may result in dislocation, reduced range of motion, or accelerated wear. This study reports accuracy of a tactile
Introduction. We report 10-year clinical outcomes of a prospective randomised controlled study on uni-compartmental knee arthroplasty using an active constraint robot. Measuring the clinical impact of CAOS systems has generally been based around surrogate radiological measures with currently few long-term functional follow-up studies reported. We present 10 year clinical follow up results of robotic vs conventional surgery in UKA. Material and methods. The initial study took place in 2004 and included 28 patients, 13 in the
INTRODUCTION. Acetabular cup malpositioning has been implicated in instability and wear-related complications after total hip arthroplasty. Although computer navigation and robotic assistance have been shown to improve the precision of implant placement, most surgeons use mechanical and visual guides to place acetabular components. Authors have shown that, when using a bean bag positioner, mechanical guides are misleading as they are unable to account for the variability in pelvic orientation during positioning and surgery. However, more rigid patient positioning devices may allow for more accurate free hand cup placement. To our knowledge, no study has assessed the ability of rigid devices to afford surgeons with ideal pelvic positioning throughout surgery. The purpose of this study is to utilize robotic-arm assisted computer navigation to assess the reliability of pelvic position in total hip arthroplasty performed on patients positioned with rigid positioning devices. METHODS. 100 hips (94 patients) prospectively underwent total hip Makoplasty in the lateral decubitus position from the posterior approach; 77 stabilized by universal lateral positioner, and 23 by peg board. After dislocation but prior to reaming, one fellowship trained arthroplasty surgeon manually placed the
This paper illustrates the concept of a versatile surgical assistance system which combines an optical navigation system and a
Fluid film lubricating ability of a total hip prosthesis depends on the profile accuracies including surface-roughness or the sphericity of a head or a cup. Therefore, surface polishing is important. It was, however, difficult to polish the central portion of a cup or head using the conventional rotating machine. In the present study, we developed a polishing method combining a pendulum machine and a
Introduction. Background: Trochanteric bursitis is a common and poorly understood complication following total hip arthroplasty (THA). The purpose of this study was to evaluate the incidence of symptomatic trochanteric bursitis and the change in hip offset among THA patients before and after the introduction of robotic assistance. Methods. Retrospective chart review of THAs performed by a single over a 3-year period between 1/5/2013 and 6/28/2016. Between 1/5/2013 and 11/11/2014 101 consecutive patients were identified that underwent manual posterior-lateral THA that utilized traditional cup positioning method based on AP Pelvis radiograph. The subsequent six-month period during a complete transition to
There is an increasing prevalence of haptic devices in many engineering fields, especially in medicine and specifically in surgery. The stereotactic haptic boundaries used in Computer Aided Orthopaedic Surgery Unicomparmental Knee Arthroplasty (CAOS UKA) systems for assistive milling control can lead to an increase in the force required to manipulate the device; this study presented here has seen a several fold increase in peak forces between haptic and non-haptic conditions of a semi-active preoperative image system. Orthopaedic Arthroplasty surgeons are required to apply forces ranging from large gripping forces to small forces for delicate manipulation of tools and through a large range of postures. There is also a need for surgeons to move around and position themselves to gain line of sight with the object of interest and to operate while wearing additional clothing such as the protective headwear and double gloves. These factors further complicate comparison with other ergonomic studies of other robotics systems. While robotics has been implemented to reduce fatigue in surgery one area of concern in CAOS is localised user muscle fatigue in high volume use. In order to create the conditions necessary for the generation of fatigue in a realistic user experience, but in the time available for the participants, an extended period of controlled and prolonged cutting and manipulation of the
INTRODUCTION. we have previously reported that bone preparation is quite precise and accurate relative to a preoperative plan when using a
The paper presents the design of a mechatronic assistance system which started from the novel concept to integrate an optical navigation system and a
Background. Use of a robotic tool to perform surgery introduces a risk of unexpected soft tissue damage due to the uncommon tactile feedback for the surgeon. Early experience with robotics in total hip and knee replacement surgery reported having to abort the procedure in 18–34 percent of cases due to inability to complete preoperative planning, hardware and soft tissue issues, registration issues, as well as concerns over actual and potential soft tissue damage. These can result in significant morbidity to the patient, negating all the desired advantages of precision and reproducibility with robotic assisted surgery. The risk of soft tissue damage can be mitigated by haptic software prohibiting the cutting tip from striking vital soft tissues and by the surgeon making sure there is a clear workspace path for the cutting tool. This robotic total knee system with a semi-active haptic guided technique was approved by the FDA on 8/5/2015 and commercialized in August of 2016. Two year clinical results have not been reported to date. Objective. To review an initial and consecutive series of robotic total knee arthroplasties for safety in regard to avoidance of known or delayed soft tissue injuries and the necessity to abort the using the robot to complete the procedure. Report the clinical outcomes with robotic total knee replacement at or beyond two years to demonstrate no delayed effect on expected outcome. Methods. The initial consecutive series of 65 Triathlon. TM. total knee replacements using a semi-active haptic guided system that were performed after commercialization that would be eligible for two year follow-up were reviewed. Pre-operative planning utilizing CT determined the implant placement and boundaries and thus the limit of excursion from any part of the end effector saw tip. Self-retaining retractors were also utilized. Operative reports, 2, 6, and 12 week, and yearly follow-up visit reports were reviewed for any evidence of inadvertent injury to the medial collateral ligament, patellar tendon, or a neurovascular structure from the cutting tool. Operative notes were also reviewed to determine if the robotic procedure was partially or completely aborted due to any issue. Knee Society Knee Scores (KS-KS) and Functional Scores (KS-FS) were recorded from pre-operative and yearly. Any complications were recorded. Results. 40 cases had two year follow-up. The average follow-up for this series was 1.51 years. No cases were unable to be completed robotically. No case had evidence for acute or delayed injury to the medial collateral ligament, patellar tendon, or neurovascular structure. The only complication was a revision total knee for tibial component loosening after a fall induced periprosthetic tibial fracture. Average pre-operative KS-KS and KS-FS improved from 46.9 and 52.1 to 99.2 and 88.6 at one year follow-up, 100.5 and 86.9 at two year follow-up. Conclusions. A semi-active haptic guided robotic system is a safe and reliable method to perform total knee replacement surgery. This series of initial
The use of robotics in total joint arthroplasty is the latest in a long list of expensive technologies that promise multiple positive outcomes, but come with an expensive price tag. In the last decade alone we've seen the same claims for navigation and patient specific instruments and implants. There are various current systems available including a
Background. Manually instrumented knee arthroplasty is associated with variability in implant and limb alignment and ligament balance. When malalignment, patellar maltracking, soft tissue impingement or ligament instability result, this can lead to decreased patient satisfaction and early failure. Robotic technology was introduced to improve surgical planning and execution. Haptic robotic-arm assisted total knee arthroplasty (TKA) leverages three-dimensional planning, optical navigation, dynamic intraoperative assessment of soft tissue laxity, and guided bone preparation utilizing a power saw constrained within haptic boundaries by the
Introduction. The purpose of this study is to compare total and rate of caloric energy expenditure between conventional and robotic-arm assisted total knee arthroplasty (TKA) between a high volume “veteran” surgeon (HV) and a lower volume, less experienced surgeon (LV). Methods. Two specialized arthroplasty surgeons wore a biometric-enabled shirt and energy expenditure outcomes were measured (total caloric expenditure, kilocalories per minute, heart rate variability, and surgical duration) during 35 conventional (CTKA) and 29 robotic primary total knee arthroplasty (RTKA) procedures. Results. Overall, the rate of caloric expenditure was similar between RTKA (5.60 ±2.50 kcal/min) and CTKA (4.79cal/min ±1.79, p=0.25). With 6.15 minute longer operative times, the total energy expenditure (TEE) for RTKA (239.31±96.79 kcal) was higher thanCTKA(181.54 ±80.90 kcal, p<0.001). The HV surgeon's TEE (p<0.001) and rate of energy expenditure (REE) (p<0.001) were significantly higher in RTKA (261.53cal; 6.499cal/min) versus CTKA (71.00cal; 3.759cal/min). However, the LV surgeon's TEE and REE for RTKA (207.83cal; 4.32cal/min) and CTKA (195.81cal; 4.92cal/min) were not significantly different (p>0.05). Both surgeons (HV; LV) had significantly longer surgical durations (p<0.001) in RTKA (40.41 ±4.94min; 48.91 ±8.45min) compared to CTKA surgeries (18.75±4.27min; 40.4 ±8.34min), respectively. Conclusion. While REE did not varybetween CTKA and RTKA for the LV surgeon, it did vary significantly for the HV surgeon. Additionally, RTKA took longer and increased TEE, but one less operating room assistant was needed. Surgeons with less experience in TKA may be less likely to notice a difference in energy expenditure when utilizing robotic-arm assisted technology. It is possible that more experience with using the
To introduce a new robot-assisted surgical system for spinal posterior fixation which called TiRobot, based on intraoperative three-dimensional images. TiRobot has three components: the planning and navigation system, optical tracking system and
Robotic-assisted total knee arthroplasty (TKA) has proven higher accuracy, fewer alignment outliers, and improved short-term clinical outcomes when compared to conventional TKA. However, evidence of cost-effectiveness and individual superiority of one system over another is the subject of further research. Despite its growing adoption rate, published results are still limited and comparative studies are scarce. This review compares characteristics and performance of five currently available systems, focusing on the information and feedback each system provides to the surgeon, what the systems allow the surgeon to modify during the operation, and how each system then aids execution of the surgical plan. Cite this article: Abstract
Purpose. The goal of Total Ankle Arthroplasty (TAA) is to relieve pain and restore healthy function of the intact ankle. Restoring intact ankle kinematics is an important step in restoring normal function to the joint. Previous robotic laxity testing and functional activity simulation showed the intact and implanted motion of the tibia relative to the calcaneus is similar. However there is limited data on the tibiotalar joint in either the intact or implanted state. This current study compares modern anatomically designed TAA to intact tibiotalar motion. Method. A robotic testing system including a 6 DOF load cell (AMTI, Waltham, MA) was used to evaluate a simulated functional activity before and after implantation of a modern anatomically designed TAA (Figure 1). An experienced foot and ankle surgeon performed TAA on five fresh-frozen cadaveric specimens. The specimen tibia and fibula were potted and affixed to the
The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system. The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.Aims
Methods
Introduction. The longevity of total hip arthroplasty (THA) is dependent on acetabular component position. We measured the reliability and accuracy of a CT-based navigation system to achieve the intended acetabular component position and orientation using three dimensional imaging. The purpose of the current study was to determine if the CT-guided robotic navigation system could accurately achieve the desired acetabular component position (center of rotation (COR)) and orientation (inclination and anteversion). The postoperative orientation and location of the components was determined in 20 patients undergoing THA using CT images, the gold standard for acetabular component orientation. Methods. Twenty primary unilateral THA patients were enrolled in this IRB-approved, prospective cohort study to assess the accuracy of the robotic navigation system. Pre- and post-operative CT exams were obtained and aligned 3D segmented models were used to measure the difference in center of rotation and orientation (anteversion and inclination). Patients with pre-existing implants, posttraumatic arthritis, contralateral hip arthroplasty, septic arthritis, or previous hip fracture were excluded. All patients underwent unilateral THA using
While image guidance and neuro-navigation have enabled a more accurate positioning of pedicle implants, robot-assisted placement of pedicle screws appears to overcome the disadvantages of the two first systems. However, recent data concerning the superiority of robots currently available to assist spinal surgeons in the accurate positioning of implants are conflicting. The aim of our study was to evaluate the percentage of accurate positioning of pedicle screws inserted using a new robotic-guidance system. Patients were operated on successively by the same surgeon using robotic-assistance (RA; n=40) or by the freehand conventional technique (FH; n=54). Ten and eleven patients from the robot (RG) and freehand (FHG) groups respectively, age-matched and all suffering from degenerative lumbar spine disease were compared. Patient characteristics as well as the duration of the operation and of exposure to X-rays were recorded. The Gertzbein Robbins classification was used to evaluate implant placement. Data wer compared between the groups. Pedicle screw placement in RG patients was achieved using the ROSA™ (Medtech) robot comprising a compact
Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies. Cite this article:
INTRODUCTION:. Unicompartmental knee replacement (UKR) facilitates the use of smaller sized implants that require less bone resection and allows preservation of the anterior and posterior cruciate ligaments (ACL and PCL)[1]. Therefore, UKR preserves the intact kinematics and may improve the clinical outcomes especially compared to the outcomes of total knee replacement (TKA). Despite the known benefits of UKR in arthritis limited to one compartment, in multicompartment disease TKA remains the gold standard. Current TKA designs require the sacrifice of the ACL in all cases, whereas the surgeon can decide to use a cruciate sparing or substituting design altering normal knee kinematics. Performing bi-UKR or tri-UKR with traditional instruments is very challenging and rarely done due to the difficulty in establishing the correct spatial relationship of the separate components. Recent advances in robotic surgery have provided the opportunity to utilize partial knee replacements. The MAKO Rio platform is a surgeon-interactive
Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted total hip arthroplasty (RO THA) compared with the conventional technique (CO THA). This large-scale, single-institution study included 1,607 patients of any age who underwent 1,732 primary THAs for any indication between May 2019 and January 2023. The data which were collected included the demographics of the patients, LOS, type of anaesthetic, the need for treatment in a post-anaesthesia care unit (PACU), readmission within 30 days, and discharge disposition. Univariate and multivariate logistic regression models were used to identify factors and the characteristics of patients which were associated with delayed discharge.Aims
Methods
Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).Aims
Methods
Introduction:. Following total knee arthroplasty, patients often complain of an unnatural feeling in their knee joint, which in turn limits their activities [Noble et al, CORR 2006]. To develop an implant design that recreates the motion of the natural knee, both the functional kinematics as well as the laxity of the joint need to be understood. In vitro testing that accurately quantifies the functional kinematics and laxity of the knee joint can facilitate development of implant designs that are more likely to result in a natural feeling, reconstructed knee. The objective of this study is to demonstrate that robotic in vitro testing can produce clinically relevant functional kinematics and joint laxities. Methods:. All testing was performed using a KUKA (KUKA Robotics, Augsburg, Germany) 6 degree of freedom
Introduction. In total hip arthroplasty, the positioning of the acetabular cup, in particular, has been shown to play an important role in the survivorship of the prosthetic joint. The commonly accepted “safe zone” extends from 5–30° of anteversion to 30–50° of inclination. However, several studies have utilized a more restrictive safe zone of 5–25° of anteversion and 30–45° of inclination, a modification of the Lewinnek zone. Many attempts have been made to develop a more reliable method of positioning the acetabular component. Robotic-assisted surgery is one such method. The purpose of this study was to compare the resulting position of the acetabular component after robotic-assisted surgery with the intraoperative robotic data to determine if improved accuracy can be achieved with the robotic-assisted method. Methods. One hundred and nineteen patients received THA, at four different medical centers in the United States, using a haptic
Introduction: Functional results of hemiarthroplasties in proximal humeral fractures are unpredictable. The correct consolidation of the tuberosities back to the prosthesis seem to be of capital importance in the functional outcome. The objective of the study is to analyze the changes of the tension registered in the sutures passed through the tuberosities when changing the height and version of the prosthesis in a static model and in a dynamic model. Material and Method: Prosthesis positioning: in both static and dynamic model, the prosthesis was placed in anatomical position, anatomical increasing 20° retroversion, increasing height in 1cm and anatomical version, decreasing height in 1 cm and anatomical version, increasing height in 1cm and increasing 20° retroversion, decreasing height in 1 cm and increasing 20° retroversion,. Static study: a 4-part fracture was reproduced in four fresh-frozen shoulder specimens. Sutures were placed between lesser tuberosity and diafisis (sensor 1) between both tuberosities (sensor 2) and between greater tuberosity and diafisis (sensor 3). Traction was performed through supraspinatus, infraspinatus and subescapularis attachments until the breakage of the suture or 1 cm gap between bony fragments. Tensions registered in a computer model. Dynamic study: a 4-part fracture was reproduced in a humeral saw bone. Sutures placed in the same position that in the static model. Saw bone fixed at a
The December 2022 Hip & Pelvis Roundup360 looks at: Fix and replace: simultaneous fracture fixation and hip arthroplasty for acetabular fractures in older patients; Is the revision rate for femoral neck fracture lower for total hip arthroplasty than for hemiarthroplasty?; Femoral periprosthetic fractures: data from the COMPOSE cohort study; Dual-mobility cups and fracture of the femur; What’s the deal with outcomes for hip and knee arthroplasty outcomes internationally?; Osteochondral lesions of the femoral head: is costal cartilage the answer?
Introduction. Clinical outcomes of UKA procedures are sensitive to malalignment of the components, and thus show significant variability in the literature. A new robotic procedure addresses isolated medial compartment osteoarthritis with the classic indications of UKA. Using precision planning through patient specific 3D modeling and reconstruction, a
Formal surgical skill assessment and critical path analysis are not widely used in orthopaedic surgical training due to the lack of technology for objective quantification, reliability, and the discrimination insensitivity of existing methods. Current surgical skill assessment methods also require additional instrumentation, cost and time. Such problems can be overcome by a novel method that records the motion of surgical instrumentation for the purposes of documentation, surgical-skill assessment, and safety analysis. This method uses an existing computer-aided-orthopedic-surgery (CAOS) navigation system and does not compromise its functions of real-time tracking, rendering, or simulation. The stored data allows realistic playback in 3D of the complete bone cutting/refining process. This concept and its sensitivity were previously tested and validated using a
Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.Aims
Methods
No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model. A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data.Aims
Methods
Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology. This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°).Aims
Methods
This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.Aims
Methods