Advertisement for orthosearch.org.uk
Results 1 - 50 of 110
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 319 - 319
1 May 2010
Rodríguez-Merchán E
Full Access

Introduction: Althoug the advantages of partial revision in hip replacement are well-documented, the effectiveness of this treatment strategy has not been established in revision TKA. The purpose of this study is compare the results of tibial component versus full–component (Miller-Galante II-MG II to Constrained Condylar Knee-CCK) revision TKA for wear-related problems.

Materials and Methods: A retrospective review was used to identify who had partial revision TKA. Over a 10-year period, 55 revision TKAs were completed. All the primary arthroplasties were MG II hybrid primary arthroplasties (uncemented femoral component, cemented tibial component, cemented patellar resurfacing). Twenty-five partial revisions (tibial component and polyethylene exchange) and 30 full-component revision TKAs were done. The average follow-up was 5.2 years. Knee Society clinical scores were used to compare patients who had tibial revision with patients who had full-component revision.

Results: The average Knee Society score for full component revisions was 85 compared to 63 for partial revisions (significant difference).

Discussion and Conclusion: We recommend caution in doing isolated tibial revisions in which retaining the femoral component limits the surgeon options to properly balance the knee. Full revision should be done if there is any question regarding ligamentous balancing or equalization of flexion and extension gaps.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 526 - 533
1 May 2023
Harmer JR Wyles CC Duong SQ Morgan III RJ Maradit-Kremers H Abdel MP

Aims

The aim of this study was to determine the prevalence of depressive and anxiety disorders prior to total hip (THA) and total knee arthroplasty (TKA) and to assess their impact on the rates of any infection, revision, or reoperation.

Methods

Between January 2000 and March 2019, 21,469 primary and revision arthroplasties (10,011 THAs; 11,458 TKAs), which were undertaken in 15,504 patients at a single academic medical centre, were identified from a 27-county linked electronic medical record (EMR) system. Depressive and anxiety disorders were identified by diagnoses in the EMR or by using a natural language processing program with subsequent validation from review of the medical records. Patients with mental health diagnoses other than anxiety or depression were excluded.


Bone & Joint Open
Vol. 3, Issue 2 | Pages 107 - 113
1 Feb 2022
Brunt ACC Gillespie M Holland G Brenkel I Walmsley P

Aims

Periprosthetic joint infection (PJI) occurs in approximately 1% to 2% of total knee arthroplasties (TKA) presenting multiple challenges, such as difficulty in diagnosis, technical complexity, and financial costs. Two-stage exchange is the gold standard for treating PJI but emerging evidence suggests 'two-in-one' single-stage revision as an alternative, delivering comparable outcomes, reduced morbidity, and cost-effectiveness. This study investigates five-year results of modified single-stage revision for treatment of PJI following TKA with bone loss.

Methods

Patients were identified from prospective data on all TKA patients with PJI following the primary procedure. Inclusion criteria were: revision for PJI with bone loss requiring reconstruction, and a minimum five years’ follow-up. Patients were followed up for recurrent infection and assessment of function. Tools used to assess function were Oxford Knee Score (OKS) and American Knee Society Score (AKSS).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims. We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. Methods. The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. Results. The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. Conclusion. We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability. Cite this article: Bone Joint J 2022;104-B(10):1126–1131


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1103 - 1110
1 Jun 2021
Tetreault MW Hines JT Berry DJ Pagnano MW Trousdale RT Abdel MP

Aims. This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA). Methods. From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded. Results. Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years. Conclusion. After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 158 - 164
1 Jun 2021
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi MP

Aims. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. Because there are few studies evaluating mid-term outcomes with a sufficient cohort, the purpose of this study was to evaluate tibial cone survival and complications in revision TKAs with tibial cones at minimum follow-up of five years. Methods. A retrospective review was completed from September 2006 to March 2015, evaluating 67 revision TKAs (64 patients) that received one specific porous tibial cone during revision TKA. The final cohort was composed of 62 knees (59 patients) with five years of clinical follow-up or reoperation. The mean clinical follow-up of the TKAs with minimum five-year clinical follow-up was 7.6 years (5.0 to 13.3). Survivorship analysis was performed with the endpoints of tibial cone revision for aseptic loosening, tibial cone revision for any reason, and reoperation. We also evaluated periprosthetic joint infection (PJI), risk factors for failure, and performed a radiological review. Results. The rate of cone revision for aseptic loosening was 6.5%, with an eight-year survival of 95%. Significant bone loss (Anderson Orthopaedic Research Institute grade 3) was associated with cone revision for aseptic loosening (p = 0.002). The rate of cone revision for any reason was 17.7%, with an eight-year survival of 84%. Sixteen percent of knees developed PJI following revision. A pre-revision diagnosis of reimplantation as part of a two-stage exchange protocol for infection was associated with both PJI (p < 0.001) and tibial cone revision (p = 0.001). Conclusion. Mid-term results of tibial cones showed a survivorship free of cone revision for aseptic loosening of 95%. Patients with significant bone loss were more likely to have re-revision for tibial cone failure. Infection was common, and patients receiving cones at reimplantation were more likely to develop PJI and undergo cone revision. Cite this article: Bone Joint J 2021;103-B(6 Supple A):158–164


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 46 - 46
1 Dec 2022
Sheridan G Garbuz D Masri B
Full Access

The demand for revision total knee arthroplasty (TKA) has grown significantly in recent years. The two major fixation methods for stems in revision TKA include cemented and ‘hybrid’ fixation. We explore the optimal fixation method using data from recent, well-designed comparative studies. We performed a systematic review of comparative studies published within the last 10 years with a minimum follow-up of 24 months. To allow for missing data, a random-effects meta-analysis of all available cases was performed. The odds ratio (OR) for the relevant outcome was calculated with 95% confidence intervals. The effects of small studies were analyzed using a funnel plot, and asymmetry was assessed using Egger's test. The primary outcome measure was all-cause failure. Secondary outcome measures included all-cause revision, aseptic revision and radiographic failure. There was a significantly lower failure rate for hybrid stems when compared to cemented stems (p = 0.006) (OR 0.61, 95% CI 0.42-0.87). Heterogeneity was 4.3% and insignificant (p = 0.39). There was a trend toward superior hybrid performance for all other outcome measures including all-cause re-revision, aseptic re-revision and radiographic failure. Recent evidence suggests a significantly lower failure rate for hybrid stems in revision TKA. There is also a trend favoring the use of hybrid stems for all outcome variables assessed in this study. This is the first time a significant difference in outcome has been demonstrated through systematic review of these two modes of stem fixation. We therefore recommend the use, where possible, of hybrid stems in revision TKA


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 16 - 16
1 Feb 2020
Song S Kang S Park C
Full Access

Background. As life expectancy increases, the number of octogenarians requiring primary and revision total knee arthroplasty (TKA) is increasing. Recently, primary TKA has become a common treatment option in octogenarians. However, surgeons are still hesitant about performing revision TKA on octogenarians because of concerning about risk- and cost-benefit. The purpose of this study was to investigate postoperative complications and mid-term survival in octogenarians following primary and revision total knee arthroplasty (TKA). Methods. We retrospectively reviewed 231 primary TKAs and 41 revision TKAs performed on octogenarians between 2000 and 2016. The mean age was 81.9 for primary TKA and 82.3 for revision TKA (p=0.310). The American Society of Anesthesiologists (ASA) score was not different, but the age-adjusted Charlson comorbidity index was higher in revision TKA (4.4 vs. 4.8, p=0.003). The mean follow-up period did not differ (3.8 vs. 3.5 years, p=0.451). The WOMAC scores and range of motion (ROM) were evaluated. The incidence of postoperative complication and survival rate (end point; death determined by telephone or mail communication with patient or family) were investigated. Results. The postoperative WOMAC and ROM were better in primary TKA (33.1 vs. 47.2, p<0.001; 128.9° vs. 113.6°, p<0.001). The most common postoperative complication was delirium in both groups (7.4% vs. 14.6%, p=0.131). There were no differences in the specific complication rates between the two groups. The 5- and 10-year survival rates were 87.2% and 62.9%, respectively, in primary TKA and 82.1% and 42.2%, respectively, in revision TKA (p=0.017). Conclusions. Both primary and revision TKAs are viable options for octogenarians when considering the clinical results and mid-term survival. Delirium needs to be managed appropriately as the most common complication in both primary and revision TKAs for octogenarians


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 56 - 56
1 Oct 2022
Stevoska S Himmelbauer F Stiftinger J Stadler C Pisecky L Gotterbarm T Klasan A
Full Access

Aim. Antimicrobial resistance (AMR) aggravates an already difficult treatment of periprosthetic joint infections (PJI). The prevalence of drug-resistant pathogens varies across countries and increases over time. Regular monitoring of bacteriological analyses should be performed. Due to many factors influencing the AMR, the correct choice of antimicrobial management remains arguable. The primary purpose of this retrospective study was to identify and compare causative bacteria and to compare the incidence of antibiotic resistance between the septic revision total knee arthroplasty (TKA) and septic revision total hip arthroplasty (THA). Method. A review of all revision TKAs and revision THAs, undertaken between 2007 and 2020 in a tertiary referral centre, was performed. Included were cases meeting the consensus criteria for PJI, in which an organism has been identified. There were no major differences in tissue sampling between revision TKAs and revision THAs over time. Results. A total of 228 bacterial strains, isolated after revision TKA and THA, were analysed for their resistance to 20 different antibiotics. There was a statistically significant higher occurrence of Gram-negative bacteria (p=0.002) and Enterococcus species (p=0.026) identified after revision THAs compared to TKA. The comparison of antibiotic resistance between revision TKAs and revision THAs was statistically significant in 9 of 20 analysed antibiotics. Pathogens isolated after revision THA were much more resistant compared to pathogens isolated after revision TKA. Resistance in revision THAs was significantly higher to oxacillin (p=0.03), ciprofloxacin (p<0.001), levofloxacin (p<0.001), moxifloxacin (p=0.005), clindamycin (p<0.001), co-trimoxazole (p<0.001), imipenem (p=0.01), rifampicin (p=0.005) and tetracycline (p=0.009). There was no significantly higher resistance of pathogens isolated after revision TKAs detected. No statistically significant difference in antibiotic resistance of Gram-negative bacteria between revision TKA and revision THA was observed. Conclusions. The occurrence and the resistance of bacteria to antibiotics differs significantly between revision TKAs and revision THAs. This has implications on of the choice of empirical antibiotic in revision surgery as well as prophylactic antibiotic in primary surgery, depending on the joint that is to be replaced


Full Access

Abstract. Approximately 20% of primary and revision Total Knee Arthroplasty (TKA) patients require multiple revisions, which are associated with poor survivorship, with worsening outcomes for subsequent revisions. For revision surgery, either endoprosthetic replacements or metaphyseal sleeves can be used for the repair, however, in cases of severe defects that are deemed “too severe” for reconstruction, endoprosthetic replacement of the affected area is recommended. However, endoprosthetic replacements have been associated with high complication rates (high incidence rates of prosthetic joint infection), while metaphyseal sleeves have a more acceptable complication profile and are therefore preferred. Despite this, no guidance exists as to the maximal limit of bone loss, which is acceptable for the use of metaphyseal sleeves to ensure sufficient axial and rotational stability. Therefore, this study assessed the effect of increasing bone loss on the primary stability of the metaphyseal sleeve in the proximal tibia to determine the maximal bone loss that retains axial and rotational stability comparable to a no defect control. Methods. to determine the pattern of bone loss and the average defect size that corresponds to the clinically defined defect sizes of small, medium and large defects, a series of pre-operative x-rays of patients with who underwent revision TKA were retrospectively analysed. Ten tibiae sawbones were used for the experiment. To prepare the bones, the joint surface was resected the typical resection depth required during a primary TKA (10mm). Each tibia was secured distally in a metal pot with perpendicular screws to ensure rotational and axial fixation to the testing machine. Based on X-ray findings, a fine guide wire was placed 5mm below the cut joint surface in the most medial region of the plateau. Core drills (15mm, 25mm and 35mm) corresponding to small, medium and large defects were passed over the guide wire allowing to act at the centre point, before the bone defect was created. The test was carried out on a control specimen with no defect, and subsequently on a Sawbone with a small, medium or large defect. Sleeves were inserted using the published operative technique, by trained individual using standard instruments supplied by the manufacturers. Standard axial pull-out (0 – 10mm) force and torque (0 – 30°) tests were carried out, recording the force (N) vs. displacement (mm) curves. Results. A circular defect pattern was identified across all defects, with the centre of the defect located 5mm below the medial tibial base plate, and as medial as possible. Unlike with large defects, small and medium sized defects reduced the pull-out force and torque at the bone-implant interface, however, these reductions were not statistically significant when compared to no bony defect. Conclusions. This experimental study demonstrated that up to 35mm radial defects may be an acceptable “critical limit” for bone loss below which metaphyseal sleeve use may still be appropriate. Further clinical assessment may help to confirm the findings of this experimental study. This study is the first in the literature to aim to quantify “critical bone loss” limit in the tibia for revision knee arthroplasty. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint Open
Vol. 1, Issue 3 | Pages 29 - 34
13 Mar 2020
Stirling P Middleton SD Brenkel IJ Walmsley PJ

Introduction. The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary TKA. The secondary aim was to compare incidence of complications and length of stay (LOS) between the two groups. Methods. Patients undergoing revision TKA for all diagnoses between 2009 and 2016 had patient-reported outcome measures (PROMs) collected prospectively. PROMs consisted of the American Knee Society Score (AKSS) and Short-Form 12 (SF-12). The study cohort was identified retrospectively and demographics were collected. The cohort was matched to a control group of patients undergoing primary TKA. Results. Overall, 72 patients underwent revision TKA and were matched with 72 primary TKAs with a mean follow-up of 57 months (standard deviation (SD) 20 months). The only significant difference in postoperative PROMs was a worse AKSS pain score in the revision group (36 vs 44, p = 0.002); however, these patients still produced an improvement in the pain score. There was no significant difference in improvement of AKSS or SF-12 between the two groups. LOS (9.3 days vs 4.6 days) and operation time (1 hour 56 minutes vs 1 hour 7 minutes) were significantly higher in the revision group (p < 0.001). Patients undergoing revision were significantly more likely to require intraoperative lateral release and postoperative urinary catheterisation (p < 0.001). Conclusion. This matched-cohort study provides results of revision TKA using modern techniques and implants and outlines what results patients can expect to achieve using primary TKA as a control. This should be useful to clinicians counselling patients for revision TKA


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


Bone & Joint Open
Vol. 2, Issue 10 | Pages 785 - 795
1 Oct 2021
Matar HE Porter PJ Porter ML

Aims. Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA). Methods. Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence. Results. We included 38 heterogeneous studies (two randomized controlled trials, six comparative studies, 19 case series, and 11 case reports). The evidence indicates that metal hypersensitivity is a rare complication with some histopathological features leading to pain and dissatisfaction with no reliable screening tests preoperatively. Hypoallergenic implants are viable alternatives for patients with self-reported/confirmed metal hypersensitivity if declared preoperatively; however, concerns remain over their long-term outcomes with ceramic implants outperforming titanium nitride-coated implants and informed consent is paramount. For patients presenting with painful TKA, metal hypersensitivity is a diagnosis of exclusion where patch skin testing, lymphocyte transformation test, and synovial biopsies are useful adjuncts before revision surgery is undertaken to hypoallergenic implants with shared decision-making and informed consent. Conclusion. Using the limited available evidence in the literature, we provide a practical approach to metal hypersensitivity in TKA patients. Future national/registry-based studies are needed to identify the scale of metal hypersensitivity, agreed diagnostic criteria, and management strategies. Cite this article: Bone Jt Open 2021;2(10):785–795


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims. Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m. 2. (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6). Results. Survivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully. Conclusion. Novel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1087 - 1092
1 Sep 2019
Garceau S Warschawski Y Dahduli O Alshaygy I Wolfstadt J Backstein D

Aims. The aim of this study was to assess the effects of transferring patients to a specialized arthroplasty centre between the first and second stages (interstage) of prosthetic joint infection (PJI) of the knee. Patients and Methods. A search of our institutional database was performed to identify patients having undergone two-stage revision total knee arthroplasty (TKA) for PJI. Two cohorts were created: continuous care (CC) and transferred care (TC). Baseline characteristics and outcomes were collected and compared between cohorts. Results. A total of 137 patients were identified: 105 in the CC cohort (56 men, 49 women; mean age 67.9) and 32 in the TC cohort (17 men, 15 women; mean age 67.8 years). PJI organism virulence was greater in the CC cohort (36.2% vs 15.6%; p = 0.030). TC patients had a higher rate of persisting or recurrent infection (53.6% vs 13.4%; p < 0.001), soft-tissue complications (31.3 vs 14.3%; p = 0.030), and reduced requirement for porous metal augments (78.1% vs 94.3%; p = 0.006). Repeat first stage debridement after transfer led to greater need for plastic surgical procedures (58.3% vs 0.0%; p < 0.001). Conclusion. Patient transfer during the interstage of treatment for infected TKA leads to poorer outcomes compared with patients receiving all their treatment at a specialized arthroplasty centre. Cite this article: Bone Joint J 2019;101-B:1087–1092


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 18 - 18
1 Dec 2021
Warren J Anis H Bowers K Villa J Pannu T Klika AK Piuzzi N Colon-Franco J Higuera-Rueda C
Full Access

Aim. Several options to standardize the definition of periprosthetic joint infection (PJI) have been created including the 2013 Musculoskeletal Infection Society (MSIS), 2018 Intentional Consensus Meeting (ICM), and the 2019 proposed European Bone and Joint Infection Society (EBJIS) criteria. Synovial fluid biomarkers have been investigated in an effort to simplify and improve the diagnosis of PJI. The aim of this study was to test the sensitivity, specificity, positive, and negative predicted values (PPV and NPV, respectively) of a calprotectin point of care (POC) test for diagnosing PJI in revision total knee arthroplasty (TKA) patients comparing different sets of criteria (2013 MSIS, 2018 ICM, and 2019 EBJIS criteria) used to define patients as with or without infection. Method. From October 2018 to January 2020 and under IRB approval 123 intraoperative samples of synovial fluid were prospectively collected at two academic hospitals in the same institution from revision TKA patients. All patients underwent standard clinical and laboratory evaluation for PJI at our institution, allowing for categorization using the 3 criteria. Patients were adjudicated by 2 blinded and independent reviewers for the 3 sets of criteria. The 3 criteria agreed 91.8% of the time. Four likely cases by the 2019 proposed EBJIS were considered unlikely and 1 inconclusive case by the 2018 ICM was considered not infected for the purposes of analysis. Calprotectin POC testing followed manufacturer's instructions using a threshold of >50 mg/L to indicate PJI. Sensitivities, specificities, PPV, NPV, and areas under the curve (AUC) were calculated for the 3 sets of criteria. Results. Using 2013 MSIS criteria the calprotectin POC test demonstrated a sensitivity, specificity, PPV, NPV AUC of 98.1%, 95.7%, 94.5%, 98.5%, and 0.969, respectively. Using 2018 ICM the POC test demonstrated a sensitivity, specificity, PPV, NPV and (AUC) of 98.2%, 98.5%, 98.2%, 98.5%, and 0.984, respectively. Using the 2019 proposed EBJIS criteria the POC test demonstrated a sensitivity, specificity, PPV, NPV and area under the curve (AUC) of 93.2%, 100.0%, 100.0%, 94.2%, and 0.966, respectively. Conclusions. The calprotectin lateral flow POC test has an excellent sensitivity and specificity regardless of the set of criteria used to define PJI. These results are promising and suggest that the calprotectin lateral flow test may be used as a rule out test in a cost-conscious health care model or when conventional diagnostic tools may not be available. Further investigations of the calprotectin PCO test must be completed to validate these results


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims. Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). Methods. We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11). Results. Overall, 80 synovial fluid samples of 40 patients were analyzed. The average time period between the joint aspirations was 50 days (SD 32). There was a significantly higher percentage change in LC when compared to PMN% (44.1% (SD 28.6%) vs 27.3% (SD 23.7%); p = 0.003). When applying standard definition criteria, LC counts were found to skip back and forth between the two time points with exceeding the thresholds in up to 20% of cases, which was significantly more compared to PMN% for the European Bone and Joint Infection Society (EBJIS) criteria (p = 0.001), as well as for Musculoskeletal Infection Society (MSIS) (p = 0.029). Conclusion. LC and PMN% are subject to considerable variation. According to its higher interindividual variance, LC evaluation might contribute to false-positive or false-negative results in PJI assessment. Single LC testing prior to TKA revision surgery seems to be insufficient to exclude PJI. On the basis of the obtained results, PMN% analyses overrule LC measurements with regard to a conclusive diagnostic algorithm. Cite this article: Bone Jt Open 2021;2(8):566–572


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 54 - 54
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi† MP
Full Access

Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean follow-up was 5.3 years. According to the AORI classification: 8% were 1, 18% were 2A, 55% were 2B, and 19% were 3. Results. Survival analysis at 6 years showed 96% free of revision for aseptic tibial loosening, 85% free of tibial component revision for any reason, and 72% free of reoperation. Eleven knees had progressive radiolucent lines with eight having tibial construct migration on serial radiographs. Aseptic tibial loosening was associated with significant tibial bone loss, AORI 3 (p=0.0001). Tibial component revision for any reason was associated with AORI 3 (p=0.013) and a pre-revision diagnosis of reimplantation after PJI (p<0.0001). Four knees had revision for aseptic tibial loosening, 12 knees had revision of the tibial construct for reasons other than aseptic loosening (11/12 were for PJI), and 15 knees had reoperation for reasons other than tibial construct revision. Conclusions. Revision TKA with tibial cones had excellent survivorship free of revision for tibial construct aseptic loosening, 96% at 6 years. Patients receiving a tibial cone construct at the time of reimplantation for PJI were at increased risk for tibial construct revision


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 81 - 81
1 Mar 2021
Yaghmour KM Hossain F Konan S
Full Access

Abstract. Objective. In this systematic review we aim to compare wound complication rates from Negative Pressure Wound Therapy (NPWT) to dry sterile surgical dressings in primary and revision total knee arthroplasty (TKA). Methods. A search was performed using PubMed, Embase, Science Direct, and Cochrane Library. Eligible studies included those investigating the use of NPWT in primary and revision TKA. Exclusion criteria included studies investigating NPWT not related to primary or revision TKA; studies in which data relating to NPWT was not accessible; missing data; without an available full text, or not well reported. We also excluded studies with poor scientific methodology. All publications were limited to the English language. Abstracts, case reports, conference presentations, and reviews were excluded. Welch independent sample t-test was used for the statistical analysis. Results. Our review identified 11 studies evaluating 1,414 patients. Of the 1,181 primary TKA patients analysed (NPWT = 416, surgical dressing = 765), the overall wound complication rates in patients receiving NPWT ranged from 0% – 63% (Median 7.30%, SD ± 21.44) This is in comparison to complication rates of 2.8% – 19% (Median 6.50%, SD ± 6.59) in the dry dressing group. The difference in complication rates between the two groups was not statistically significant (p =0.337). In the revision TKA cohort of 279 patients (NPWT group = 128, dry dressing group = 151), the overall wound complication rates in the NPWT group ranged between 6.7% – 12% (Median 9.80%, SD ± 2.32) vs 23.8% – 30% (Median 26.95%, SD ± 2.53) in the dry dressing group. This difference was statistically significant (p<0.001). Conclusion. NPWT dressing demonstrated statistically significant reduction in wound complication rates when used in revision TKA but not primary TKA when compared to dry sterile dressings. This is probably due to higher wound related risks encountered with revision TKA surgery compared to primary TKA surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 53 - 53
1 Oct 2020
Larson D Rosenberg J Lawlor M Garvin KL Hartman C Lyden E Konigsberg B
Full Access

Introduction. Revision total knee arthroplasty (TKA) is becoming increasingly common in the United States as the population ages and larger numbers of primary TKA are performed in younger individuals. Cemented or uncemented tibial stems are frequently used in revision cases. Decreased clinical outcomes and patient satisfaction have been described for revision TKA. This study aims to determine if the presence of overall pain and tibial pain at the end of the stem differs between cemented and uncemented tibial stems in revision TKA. Methods. This was a retrospective cohort study comparing patients who underwent revision TKA utilizing cemented or uncemented tibial stems in a 15-year period at a single institution with at least two-year follow-up. Exclusion criteria included age under 18, isolated revisions of the femoral component or polyethylene exchanges, lack of preoperative or postoperative imaging, insufficient operative or implant records available for electronic chart review, revision procedures performed at outside facilities, patients who were deceased at the time of survey administration, refusal to participate in the study, and failure to return the mailed survey or respond to a telephone follow-up questionnaire. Radiographic analysis included calculation of the percentage of the tibial canal filled with the implant, as well as measurement of the diameter of the tibial stem. Radiographs were also reviewed for evidence of cavitary defects, pedestal formation, radiolucent lines, and periprosthetic fractures. Mailed surveys addressing overall pain, tibial pain, and satisfaction were analyzed using Fisher's exact test and the independent sample t-test. Logistic regression was used to adjust for age, gender, and preoperative bone loss. Results. A total of 110 patients were included (63 cemented and 47 uncemented stems). No statistically significant differences in stem length, operative side, or indications for revision were found. The uncemented group had a significantly higher percent canal fill (p < 0.0001). Tibial pain at the end of the stem was present in 25.3% of cemented stems and 25.5% of uncemented stems (p = 1.00). There was a trend towards more overall pain in the uncemented cohort, but this did not reach statistical significance. Only 74.6% of cemented patients and 78.7% of uncemented patients were satisfied following revision TKA (p = 0.66). Conclusion. The data supports our hypothesis that there are no differences in end-of-stem pain or overall pain between cemented and uncemented tibial stems in revision TKA. High rates of dissatisfaction were noted in both cohorts postoperatively, consistent with previous literature. Patient factors likely play a large role in the presence of postoperative pain. These factors should be further evaluated in future studies in an effort to reduce pain and improve patient satisfaction


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 39 - 39
1 Jul 2020
Mohamed N Castrodad I Etcheson J Gwam C George N Delanois R Jetty A Roadcloud E Elmallah R
Full Access

Revision total knee arthroplasty (TKA) procedures performed secondary to periprosthetic joint infection (PJI) are associated with significant morbidity and mortality. These poor outcomes may be further complicated by the development of postoperative infection requiring aggressive antibiotic treatment. However, this antibiotic overuse may suppress patients' native bacterial flora, leading to Clostridium difficile infection (CDI). With the increased demand for primary TKAs and expected rise in revision TKA due to PJI, it is important to identify factors contributing to CDI. Therefore, we aimed to study the: 1) incidence, 2) demographics, length of stay (LOS), and total costs, and 3) risk factors and mortality associated with CDI in revision TKA patients. The National Inpatient Sample database was queried for all individuals diagnosed with PJI and who underwent revision TKA between 2009 and 2013. Patients who developed CDI during their in-patient hospital stay were identified, yielding 83,806 patients (799 with CDI) with a mean age of 65 (S.D.=11.2). Logistic regression analysis was conducted to assess the association between hospital- and patient-specific characteristics and the development of CDI. During the study period, the overall incidence of CDI after revision TKA was 1%. These patients were significantly older (mean age 69.05 vs. 65.52 yrs), had greater LOS (median 11 vs. 5 days), had greater costs ($30,612.93 vs. 18,873.75), and had higher in-hospital mortality (3.6 vs. 0.5%, p < 0 .001 for all) compared to those without infection. Patients with CDI were more likely to be treated in urban, not-for-profit, medium or large bed-sized hospitals located in the Northeast or Midwest (p < 0 .05 for all). Patients with underlying depression (OR 4.267, p=0.007) or fluid/electrolyte disorders (OR 3.48, p=0.001) were more likely to develop infection. Although CDI is a rare event following revision TKA, it can have detrimental consequences. Our report demonstrates that CDI is associated with longer LOS, higher costs, and greater in-hospital mortality. With increased legislative pressure to lower healthcare expenditures, it is crucial to identify means of preventing costly complications


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims. Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs. Methods. A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10). Results. The five-year cumulative incidence of subsequent revision for aseptic loosening and instability were 2% (95% confidence interval (CI) 0.2 to 3, number at risk = 154) and 4% (95% CI 2 to 6, number at risk = 153), respectively. The five-year cumulative incidence of any subsequent revision was 14% (95% CI 10 to 18, number at risk = 150). Reasons for subsequent revision included PJI (n = 23, of whom 12 had previous PJI), instability (n = 13), and aseptic loosening (n = 11). The use of this implant without stems was found to be a significant risk factor for subsequent revision (hazard ratio (HR) 7.58 (95% CI 3.98 to 16.03); p = 0.007). KSS improved from 46 preoperatively to 81 at latest follow-up (p < 0.001). ROM improved from 96° prerevision to 108° at latest follow-up (p = 0.016). Conclusion. The cumulative incidence of subsequent revision for aseptic loosening and instability was very low at five years with this fixed-bearing VVC implant in revision TKAs. Routine use of cemented and stemmed components with targeted use of metaphyseal cones likely contributed to this low rate of aseptic loosening. Cite this article: Bone Joint J 2020;102-B(4):458–462


Bone & Joint Research
Vol. 7, Issue 10 | Pages 570 - 579
1 Oct 2018
Kallala R Harris WE Ibrahim M Dipane M McPherson E

Aims. Calcium sulphate has traditionally been used as a filler of dead space arising during surgery. Various complications have been described following the use of Stimulan bio-absorbable calcium sulphate beads. This study is a prospective observational study to assess the safety profile of these beads when used in revision arthroplasty, comparing the complication rates with those reported in the literature. Methods. A total of 755 patients who underwent 456 revision total knee arthroplasties (TKA) and 299 revision total hip arthroplasties (THA), with a mean follow-up of 35 months (0 to 78) were included in the study. Results. A total of 32 patients (4.2%) had wound drainage, and this was higher with higher bead volumes and in McPherson grade C patients. There was also a significantly higher bead volume in the 41 patients who developed hypercalcaemia, two of which were symptomatic (p < 0.0001). A total of 13 patients (1.7%) had heterotopic ossification (HO). There was no statistically significant relationship between the development of HO and bead volume (p > 0.05). Conclusion. The strength of this study lies in the large number of patients and the detailed data collection, making it the most comprehensive report available in the literature on the use of calcium sulphate-based bone substitutes. Cite this article: R. Kallala, W. Edwin Harris, M. Ibrahim, M. Dipane, E. McPherson. Use of Stimulan absorbable calcium sulphate beads in revision lower limb arthroplasty: Safety profile and complication rates. Bone Joint Res 2018;7:570–579. DOI: 10.1302/2046-3758.710.BJR-2017-0319.R1


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 34 - 34
1 Jan 2019
Sehgal A Burnett R Howie C Simpson H Hamilton D
Full Access

Instability accounts for approximately 20% of revision total knee arthroplasty (TKA) operations, however, diagnostic tests remain relatively subjective. The aim of this examination was to evaluate the feasibility of using pressure mat analyses during functional tasks to identify abnormal biomechanics associated with TKA instability. Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to 10 healthy controls (M = 4; age = 44.6±7.52 years; weight = 70.80±14.65). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Mann-Whitney tests compared loading parameters between groups and side-to-side differences in TKA patients (significance level = p<0.05). Pressure distribution was expressed relative to bodyweight. Notable differences were seen during bilateral stance. Uneven side loading was greater – favouring the non-operated limb – in TKA patients during bilateral stance compared to controls. This was significantly different at 30s (p=0.0336) and 60s (p=0.0336). Gait analyses showed subtle pressure distribution differences in unstable TKA patients. Stance time was indifferent. TKA patients tended to exhibit longer heel contact time (0.76s vs. 0.64s and reduced weight acceptance (50.75% vs. 56.75%) on the operated limb compared to the non-operated limb. Side-to-side differences in peak toe-off forces were significantly more pronounced in TKA patients versus controls (9.25% +/− 1.5% vs. 1.67% +/−5.79%; p=0.0039). Conclusion: This feasibility work demonstrates subtle differences in limb loading mechanics during simple clinical tests in unstable TKA patients that might be invisible to the naked eye. In the long-term, pressure analyses may be a useful diagnostic tool in identifying patients that would benefit from revision surgery for TKA instability


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 65 - 65
1 Nov 2018
Sehgal A Burnett R Howie C Simpson H Hamilton D
Full Access

Instability accounts for approximately 20% of all revision total knee arthroplasty (TKA), however diagnostic tests remain crude and subjective. The aim of this examination was to evaluate the feasibility of pressure mat (SB Mat, TekScan) analyses of functional tasks to differentiate instability in a clinical setting. Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to five healthy controls (M = 1; age = 46.80±7.85 years; weight = 71.54±16.17 kg). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Pressure distributions were expressed relative to bodyweight (%BW). T-tests compared loading parameters between groups (significance level = p<0.05). Analyses showed subtle differences in pressure distribution in unstable TKA patients versus healthy controls. Stance time during gait was indifferent. TKA patients tended to exhibit longer heel contact time (0.76 vs. 0.64 sec) and reduced weight acceptance (50.75% vs. 56.75%) on the operated versus non-operated limb. Side-to-side differences in toe-off forces were significantly more pronounced in TKA patients versus controls (9.25% vs. 3.75%; p=0.0088). Uneven loading was significantly greater – favouring the non-operated limb – in TKA patients during bilateral stance compared to controls (p<0.05). This feasibility work demonstrates subtle differences in limb loading and biomechanics during simple clinical tests in unstable TKA patients that might be undetectable to the naked eye. Pressure analyses may therefore be a useful diagnostic tool. These findings warrant further investigation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 32 - 32
1 Oct 2019
Goswami K Parvizi J
Full Access

Introduction. Next generation sequencing (NGS) has been shown to facilitate detection of microbes in a clinical sample, particularly in the setting of culture-negative periprosthetic joint infection (PJI). However, it is unknown whether every microbial DNA signal detected by NGS is clinically relevant. This multi-institutional study was conceived to 1) identify species detected by NGS that may predict PJI, then 2) build a predictive model for PJI in a developmental cohort; and 3) validate the predictive utility of the model in a separate multi-institutional cohort. Methods. This multicenter investigation involving 15 academic institutions prospectively collected samples from 194 revision total knee arthroplasties (TKA) and 184 revision hip arthroplasties (THA) between 2017–2019. Patients undergoing reimplantation or spacer exchange procedures were excluded. Synovial fluid, deep tissue and swabs were obtained at the time of surgery and shipped to MicrogenDx (Lubbock, TX) for NGS analysis. Deep tissue specimens were also sent to the institutional labs for culture. All patients were classified per the 2018 Consensus definition of PJI. Microbial DNA analysis of community similarities (ANCOM) was used to identify 17 candidate bacterial species out of 294 (W-value >50) for differentiating infected vs. noninfected cases. Logistic Regression with LASSO model selection and random forest algorithms were then used to build a model for predicting PJI. For this analysis, ICM classification was the response variable (gold standard) and the species identified through ANCOM were the predictor variables. Recruited cases were randomly split in half, with one half designated as the training set, and the other half as the validation set. Using the training set, a model for PJI diagnosis was generated. The optimal resulting model was then tested for prediction ability with the validation set. The entire model-building procedure and validation was iterated 1000 times. From the model set, distributions of overall assignment rate, specificity, sensitivity, positive predictive value (PPV) and negative predicative value (NPV) were assessed. Results. The overall predictive accuracy achieved in the model was 75.9% (Figure 1). There was a high accuracy in true-negative and false-negative classification of patients using this predictive model (Figure 2), which has previously been a criticism of NGS interpretation and reporting. Specificity was 97.1%, PPV was 75.0%, and NPV was 76.2%. On comparison of the distribution of abundances between ICM-positive and ICM-negative patients, Staphylococcus aureus was the strongest contributor (F=0.99) to the predictive power of the model (Figure 3). In contrast, Cutibacterium acnes was less predictive (F=0.309) and noted to be abundant across both infected and noninfected revision TJA samples. Discussion. This study is the first to utilize predictive modeling algorithms on a large prospective multicenter database in order to transform analytic NGS data into a clinically relevant diagnostic signal. Our collaborative findings suggest the microbial DNA signal identified on NGS may be an independent useful adjunct for the diagnosis of PJI, as well as help identify causative organisms. Further work applying artificial intelligence tools will improve accuracy, predictive power and clinical utility of high-throughput sequencing technology. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 31 - 31
1 May 2019
Cross M
Full Access

The management of bone loss in revision total knee replacement (TKA) remains a challenge. To accomplish the goals of revision TKA, the surgeon needs to choose the appropriate implant design to “fix the problem,” achieve proper component placement and alignment, and obtain robust short- and long-term fixation. Proper identification and classification of the extent of bone loss and deformity will aid in preoperative planning. Extensive bone loss may be due to progressive osteolysis (a mechanism of failure), or as a result of intraoperative component removal. The Anderson Orthopaedic Research Institute (AORI) is a useful classification system that individually describes femoral and tibial defects by the appearance, severity, and location of bone defects. This system provides a guideline to treatment and enables preoperative planning on radiographs. In Type 1 defects, femoral and tibial defects are characterised by minor contained deficiencies at the bone-implant interface. Metaphyseal bone is intact and the integrity of the joint line is not compromised. In this scenario, the best reconstruction option is to increase the thickness of bone resection and to fill the defect with cancellous bone graft or cement. Type 2 defects are characterised by deficient metaphyseal bone involving one or more femoral condyle(s) or tibial plateau(s). The peripheral rim of cortical bone may be intact or partially compromised, and the joint line is abnormal. Reconstruction options for a Type 2A defect include impaction bone grafting, cement, or more commonly, prosthetic augmentation (e.g. sleeves, augments or wedges). In Type 2B defects, metaphyseal bone of both femoral condyles or both tibial plateaus is deficient. The peripheral rim of cortical bone may be intact or partially compromised, and the joint line is abnormal. Options for a Type 2B defect include impaction grafting, bulk structural allograft, prosthetic augmentation, metaphyseal sleeves (in some cases), or metaphyseal cones. Finally, in the presence of a Type 3 deficiency, both metaphyseal and cortical bone is deficient and there is partial or complete disruption of the collateral ligament attachments. In this case, the most commonly used reconstruction options include hinged implants or megaprostheses with or without bulk structural allograft, prosthetic augmentation, and/or metaphyseal/diaphyseal sleeves or cones. Today, we are fortunate to have a wide variety of options available to aid in reconstruction of a revision TKA with massive bone loss. Historically, use of cement, bone grafting, or use of a tumor-type or hinged implant were considered the main options for reconstruction. The development and adoption of highly porous sleeves and cones has given the surgeon a new and potentially more durable option for reconstruction of previously difficult to treat defects. Using radiographs and computed tomography, surgeons are able to preoperatively classify bone loss and anticipate a reconstruction plan based upon the classification; however, it is always important to have several back-up options on hand during revision surgery in the event bone loss is worse than expected


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 64 - 64
1 Aug 2017
Hofmann A
Full Access

Exposure for revision knee requires using the previous incision, employing the “quad snip”, the “Banana Peel”, or the tubercle osteotomy. The “quad snip” is a 45-degree incision of the proximal extensor mechanism that helps protect the distal insertion on the tubercle. The “banana peel,” is my exposure of choice and has been used extensively for revision total knee arthroplasty (TKA) for more than 20 years in my community. We retrospectively reviewed use of this technique in a cohort of 100 consecutive patients who underwent tibial-femoral stemmed revision TKA. The technique involves peeling the patella tendon as a sleeve off the tibia, leaving the extensor mechanism intact with a lateral hinge of soft tissue. A quadriceps “snip” must be done proximally to avoid excessive tension. No patient has ever reported disruption of the extensor mechanism or decreased ability to extend the operative knee. With a mean Knee Society score of 176 (range, 95–200). Post-operative motion was 106 degrees. No patient reported pain over the tibial tubercle. The “banana peel” technique for exposing the knee during the revision TKA is a safe method that can be used along with a proximal quadriceps snip and does not violate the extensor mechanism, maintaining continuity of the knee extensors. As a last resort, tibial tubercle osteotomy as described by Whiteside, is preferred for revising porous coated stemmed tibial components and is repaired with cerclage wire or cables. Keep the osteotomy fragment at least 8–10cm long leaving a lateral soft tissue attachment


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 129 - 129
1 Jun 2018
Lachiewicz P
Full Access

Metaphyseal bone loss, due to loosening, osteolysis or infection, is common with revision total knee arthroplasty (TKA). Small defects can be treated with screws and cement, bone graft, and non-porous metal wedges or blocks. Large defects can be treated with bulk structural allograft, impaction grafting, or highly porous metal cones. The AORI classification of bone loss in revision TKA is very helpful with pre-operative planning. Type 1 defects do not require augments or graft—use revision components with stems. Type 2A defects should be treated with non-porous metal wedges or blocks. Type 2B and 3 defects require a bulk structural allograft or porous metal cone. Highly-porous metal metaphyseal cones are a unique solution for large bone defects. Both femoral (full or partial) and tibial (full, stepped, or cone+plate) cones are available. These cones substitute for bone loss, improve metaphyseal fixation, help correct malalignment, restore joint line, and permit use of a short cemented stem. The technique for these cones involve preparing the remaining bone with a high speed burr and rasp, followed by press-fit of the cone into the remaining metaphysis. The interface is sealed with bone graft and putty. The fixation and osteoconductive properties of the outer surface allow ingrowth and biologic fixation. The revision knee component is then implanted, with antibiotic-cement, into the porous cone inner surface, which provides superior fixation compared to cementing into deficient metaphyseal bone. There are several manufacturers that provide porous cones for knee revision, but the tantalum-“trabecular metal” cones have the largest and longest clinical follow-up. The advantages of the trabecular metal cone compared to allograft include: technically easier; biologic fixation; no resorption; and lower risk of infection. The disadvantages include: difficult extraction and intermediate-term follow-up. The author has reported the results of 33 trabecular metal cones (9 femoral, 24 tibial) implanted in 27 revision cases at 2–5.7 years follow-up. One knee (2 cones) was removed for infection. All but one cone showed osseointegration. Multiple other studies have confirmed these results. Trabecular metal cones are now the author's preferred method for the reconstruction of large bone defects in revision TKA


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 67 - 67
1 May 2019
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating preoperative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Porous metal cones or sleeves 7) Massive structural allograft-prosthetic composites; 8) Custom implants. Of these, use of uncemented highly porous metal metaphyseal cones in combination with an initial cemented or partially cemented implant has been shown to provide versatile and highly durable results for a range of bone defects including those previously requiring structural bone graft. The hybrid fixation combination of both cement and cementless fixation of an individual tibial or femoral component has emerged as a frequent and often preferred technique. Initial secure and motionless interfaces are provided by the cemented portions of the construct, while subsequent bone ingrowth to the cementless porous metal portions is the key to long term stable fixation. As bone grows into the porous portions there is off loading and protection of the cemented interfaces from mechanical stresses. While maximizing support on intact host bone has been a longstanding fundamental principle of revision arthroplasty, this is facilitated by the use of metaphyseal cones or sleeves in combination with initial fixation into the adjacent diaphysis. Preoperative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the preoperative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intraoperative findings such as occult fracture through deficient periprosthetic bone. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions, the degree of revision implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus, some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects, especially of the cavitary sort, may be well managed with minimal constraint


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 45 - 45
1 Apr 2018
Yoon C Chang C Chang M Shin J Song M Kang S
Full Access

Background. Joint line, patellar height and posterior condylar offset (PCO) are related to functional outcome such as stability and range of motion after revision total knee arthroplasty (TKA). The purpose of this study was (1) to determine whether revision TKA can restore the joint line, patella height and condylar offset after surgery, and (2) to assess factors associated with failed restoration. Materials and Methods. We retrospectively reviewed 27 consecutive patients who underwent revision TKA. Among 27 patients, 11 patients had two-stage revision TKA due to periprosthetic joint infection while 14 patients underwent revision TKA due to aseptic loosening. In addition, there were 2 patients who had traumatic event causing a periprosthetic fracture which led to revision TKA. The joint line was measured using the distance from the adductor tubercle of the femur to the most distal portion of the medial femoral component on knee anterior-posterior radiographs. Patella height was assessed using the Caton-Deschamps method. In addition, PCO were measured relative to the tangent of the posterior cortex of the femur using knee lateral radiograph. All parameters were compared between pre- and postoperative radiographs after revision TKA. Results. After revision TKA, mean joint line elevation was 0.9 mm. Seven of 27 patients showed joint line elevation of 5 mm or more. There was no significant difference between pre- and postoperative PCO (27.6 mm and 28.1 mm, respectively; P = 0.528). Fifteen patients (56%) showed patellar baja after revision TKA. Compared to the patients with aseptic loosening, the patients with periprosthetic joint infection or fracture showed greater joint line elevation (4.1 mm and −2.2 mm, respectively; P < 0.01), smaller PCO change (1.9 mm and −1.1 mm respectively, P < 0.05). Even if the cause of revision TKA was not associated with the postoperative patellar baja, presence of preoperative patellar baja was significantly associated with postoperative patellar baja (P < 0.05). Conclusions. Overall, restoration of the joint line and PCO were achieved in contemporary revision TKA. However, the patients who underwent revision TKA due to periprosthetic joint infection or fracture showed greater joint line elevation as well as smaller PCO. In addition, the patellar height was not improved in patients with preoperative patellar baja. Further evaluation of functional outcome is needed to assess correlation between radiological and functional outcome


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 104 - 104
1 Dec 2016
Lee G
Full Access

Revision total knee arthroplasty (TKA) can pose significant challenges. Successful reconstruction requires a systematic approach with the ultimate goal being a well fixed and balanced knee prosthesis. Careful preoperative planning is necessary for safe exposure, component removal, and appropriate management of bone loss during revision knee surgery. Prior to surgery, the cause of failure must be understood. Revision TKA without a clear diagnosis has been shown to lead to predictable poor results. A careful history and physical examination for both intrinsic and extrinsic causes of knee pain need to be performed. An ESR and C-reactive protein should be obtained in every patient with a painful TKA and in cases of serologic abnormalities, a joint aspiration performed. The integrity of the collateral ligaments and the degree of anticipated bone loss at the time of revision needs to be established. In cases of severe collateral ligament deficiency, the need for constrained or hinged knee implants should be anticipated. Plain radiographs are needed to evaluate present component position, loosening, and osteolysis. Oblique radiographs and advanced imaging (i.e. CT or MRI) have been shown to more accurately quantify the severity of lysis compared to standard radiographs. This careful assessment can help prepare for the need of special implants, stems, wedges, or augments. Finally, patient risk stratification and medical co-management can help minimise complications following revision TKA. Optimization of potentially modifiable risk factors such as glycemic control, BMI, and preoperative hemoglobin can reduce perioperative morbidity and complications


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 647 - 652
1 May 2017
Abdel MP Ledford CK Kobic A Taunton MJ Hanssen AD

Aims. The number of revision total knee arthroplasties (TKA) that are performed is expected to increase. However, previous reports of the causes of failure after TKA are limited in that they report the causes at specific institutions, which are often dependent on referral patterns. Our aim was to report the most common indications for re-operations and revisions in a large series of posterior-stabilised TKAs undertaken at a single institution, excluding referrals from elsewhere, which may bias the causes of failure. Patients and Methods. A total of 5098 TKAs which were undertaken between 2000 and 2012 were included in the study. Re-operations, revisions with modular component exchange, and revisions with non-modular component replacement or removal were identified from the medical records. The mean follow-up was five years (two to 12). Results. The Kaplan-Meier ten-year survival without a re-operation, modular component revision and non-modular component revision was 95.7%, 99.3% and 95.3%, respectively. The most common indications for a re-operation were: post-operative stiffness (58%), delayed wound healing (21%), and patellar clunk (11%). The indications for isolated modular component revision were acute periprosthetic joint infection (PJI) (64%) and instability (36%). The most common indications for non-modular component revision were chronic PJI (52%), aseptic loosening (17%), periprosthetic fracture (10%), and instability (10%). Conclusion. Post-operative stiffness remains the most common indication for re-operation after TKA. Infection is the most common indication for modular and non-modular component revision. Aseptic loosening was not an uncommon cause of failure, however, it was much less common than in national registry and non-registry data. Focusing on posterior-stabilised TKAs initially performed at our institution allowed for an accurate assessment of the causes of failure in a contemporary specialty practice. Cite this article: Bone Joint J 2017;99-B:647–52


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 3 - 3
1 Dec 2016
Jacobs A Menno B Meis JF Van Hellemondt G Goosen J
Full Access

Aim. Despite a preoperative workup with no evidence to suspect a prosthetic joint infection (PJI) before revision surgery, routinely obtained intraoperative cultures still can be unexpectedly positive. The purpose of this study was (1) to assess the incidence of unexpected positive intraoperative cultures in presumed aseptic knee and hip revisions and (2) to determine whether a difference exists between the infection-free implant survival rate of patients with and without unexpected positive intraoperative cultures. Method. We selected patients who underwent a one-stage revision total knee arthroplasty (TKA) or total hip arthroplasty (THA) for different reasons. Three or more separate intraoperative cultures were obtained during each procedure. A negative result was defined as less than two positive cultures with the same microorganism. An unsuspected PJI was defined as having two or more positive cultures with the same microorganism. Patients’ medical records were reviewed to collect demographics, preoperative laboratory results, culture results, and the occurrence of infection during follow-up. Results. A total of 340 and 339 patients with a presumed aseptic knee and hip revision, respectively, were analyzed. The incidence of unsuspected PJIs was 7.9% and 12.1% in the knees and hips, respectively. Of these unsuspected PJIs, the infection-free prosthetic survival rate at 2 year follow-up was 88% (95%CI 59–97) and 92% (95%CI 73–98) in knees and hips, respectively. In the knee group, the infection-free prosthetic survival rate of patients with an unsuspected PJI was significantly lower compared to that of patients with negative intraoperative culture results (88% (95%CI 59–97) versus 97% (95%CI 93–99) with p=0.01). In the hip group, there was no such a difference (92% (95%CI 73–98) versus 93% (95%CI 88–96) with p=0.41). Conclusions. We found incidences of unsuspected PJI and infection-free prosthetic survival rates that are comparable with previous studies. During follow-up after one-stage revision TKA, a higher incidence of infection was observed in patients with an unsuspected PJI. This difference was not observed in the hip revisions


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 108 - 108
1 Dec 2016
Lachiewicz P
Full Access

Metaphyseal bone loss, due to loosening, osteolysis or infection, is common with revision total knee arthroplasty (TKA). Small defects can be treated with screws and cement, bone graft, and non-porous metal wedges or blocks. Large defects can be treated with bulk structural allograft, impaction grafting, or highly porous metal cones. The AORI classification of bone loss in revision TKA is very helpful with preoperative planning. Type 1 defects do not require augments or graft—use revision components with stems. Type 2A defects should be treated with non-porous metal wedges or blocks. Type 2B and 3 defects require a bulk structural allograft or porous metal cone. Trabecular metal (TM) metaphyseal cones are a unique solution for large bone defects. Both femoral (full or partial) and tibial (full, stepped, or cone+plate) TM cones are available. These cones substitute for bone loss, improve metaphyseal fixation, help correct malalignment, restore joint line, and permit use of a short cemented stem. The technique for these cones involve preparing the remaining bone with a high speed burr and rasp, followed by press-fit of the cone into the remaining metaphysis. The interface is sealed with bone graft and putty. The fixation and osteoconductive properties of the outer surface allow ingrowth and biologic fixation. The revision knee component is then cemented into the porous cone inner surface, which provides superior fixation compared to cementing into deficient metaphyseal bone. The advantages of the TM cone compared to allograft include: technically easier; biologic fixation; no resorption; and lower risk of infection. The disadvantages include: difficult extraction and intermediate-term follow-up. The author has reported the results of 33 TM cones (9 femoral, 24 tibial) implanted in 27 revision cases at 2–5.7 years follow-up. One knee (2 cones) was removed for infection. All but one cone showed osseointegration. TM cones are now the preferred method for the reconstruction of large bone defects in revision TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 101 - 101
1 May 2016
Kim S Park Y Moon Y
Full Access

Management of the patella with poor bone stock remains a challenge in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate the results of a novel surgical technique in which widely available wires and acrylic bone cement are used in the reconstruction of a deficient patella. Twenty-eight patients (30 knees) underwent revision TKA in which a deficient patella was treated with an onlay-type prosthesis and bone-augmenting procedure, using transcortical wiring. The technique was indicated when the thickness of remnant patella was less than 8mm with variable amounts of the peripheral rim. The remaining patellar height ranged from 3.2mm to 7.3mm. Follow-up was available for all patients with a mean of 36.6 months (range, 24 to 55 months). The respective mean Knee Society scores for knee and function improved from 34.2 points (range, 18 to 65 points) and 23 points (range, 18 to 46 points) preoperatively to 73.5 points (range, 30 to 88 points) and 61points (range, 34 to 80 points) at final follow-up. The mean thickness of the patellar construct was 14.6mm (range, 12.2 – 18.3mm). One patient experienced patellar fracture during knee flexion one week after surgery. There were no complications associated with implanted hardware. A patellar bone-augmenting procedure using transcortical wiring is a straightforward technique that potentially allows firm fixation. Considering the satisfactory short- to mid-term results, we believe that this technique provides a good alternative option in addressing this challenging problem in revision TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 98 - 98
1 May 2016
Kim S Park Y Moon Y Seo J
Full Access

Background. Management of the patella with poor bone stock remains a challenge in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate the results of a novel surgical technique in which widely available wires and acrylic bone cement are used in the reconstruction of a deficient patella. Methods. Twenty-eight patients (30 knees) underwent revision TKA in which a deficient patella was treated with an onlay-type prosthesis and bone-augmenting procedure, using transcortical wiring. The technique was indicated when the thickness of remnant patella was less than 8mm with variable amounts of the peripheral rim. The remaining patellar height ranged from 3.2mm to 7.3mm. Follow-up was available for all patients with a mean of 36.6 months (range, 24 to 55 months). Results. The respective mean Knee Society scores for knee and function improved from 34.2 points (range, 18 to 65 points) and 23 points (range, 18 to 46 points) preoperatively to 73.5 points (range, 30 to 88 points) and 61points (range, 34 to 80 points) at final follow-up. The mean thickness of the patellar construct was 14.6mm (range, 12.2 – 18.3mm). One patient experienced patellar fracture during knee flexion one week after surgery. There were no complications associated with implanted hardware. Conclusions. A patellar bone-augmenting procedure using transcortical wiring is a straightforward technique that potentially allows firm fixation. Considering the satisfactory short- to mid-term results, we believe that this technique provides a good alternative option in addressing this challenging problem in revision TKA


Bone & Joint 360
Vol. 13, Issue 1 | Pages 16 - 18
1 Feb 2024

The February 2024 Knee Roundup360 looks at: Do patients with hypoallergenic total knee arthroplasty implants for metal allergy do worse? An analysis of healthcare utilizations and patient-reported outcome measures; Defining a successful total knee arthroplasty; Incidence, microbiological studies, and factors associated with periprosthetic joint infection after total knee arthroplasty; A modified Delphi consensus statement on patellar instability; Cause for concern? Significant cement coverage in retrieved metaphyseal cones after revision total knee arthroplasty; Prevalence of post-traumatic osteoarthritis after anterior cruciate ligament injury remains high despite advances in surgical techniques; Cost-effectiveness of arthroscopic partial meniscectomy versus physical therapy for traumatic meniscal tears in patients aged under 45 years.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 197 - 201
1 Feb 2015
Kallala RF Vanhegan IS Ibrahim MS Sarmah S Haddad FS

Revision total knee arthroplasty (TKA) is a complex procedure which carries both a greater risk for patients and greater cost for the treating hospital than does a primary TKA. As well as the increased cost of peri-operative investigations, blood transfusions, surgical instrumentation, implants and operating time, there is a well-documented increased length of stay which accounts for most of the actual costs associated with surgery. We compared revision surgery for infection with revision for other causes (pain, instability, aseptic loosening and fracture). Complete clinical, demographic and economic data were obtained for 168 consecutive revision TKAs performed at a tertiary referral centre between 2005 and 2012. Revision surgery for infection was associated with a mean length of stay more than double that of aseptic cases (21.5 vs 9.5 days, p < 0.0001). The mean cost of a revision for infection was more than three times that of an aseptic revision (£30 011 (. sd. 4514) vs £9655 (. sd. 599.7), p < 0.0001). . Current NHS tariffs do not fully reimburse the increased costs of providing a revision knee surgery service. Moreover, especially as greater costs are incurred for infected cases. These losses may adversely affect the provision of revision surgery in the NHS. Cite this article: Bone Joint J 2015;97-B:197–201


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 112 - 112
1 Apr 2017
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating pre-operative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Large prosthetic augments (cones); 7) Massive structural allograft-prosthetic composites (APC); 8) Custom implants. Maximizing support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Pre-operative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the pre-operative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intra-operative findings such as occult fracture through deficient periprosthetic bone. Reconstruction of bone deficiency following removal of the failed implant is largely dictated by the location and extent of bone loss and the quality of bone that remains. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions the degree of implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects especially of the cavitary sort may be well managed with minimal constraint


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 98 - 98
1 Apr 2017
Vince K
Full Access

The true results of revision total knee arthroplasty (TKA) are not fully understood, for a variety of understandable reasons. But it is has been clear for decades that revision without a diagnosis is likely to fail. The evaluation of the problem TKA should be systematic (follow the same scheme every time) and comprehensive (all possibilities should be considered even if one diagnosis seems obvious). Evaluation begins, as with all of medicine with a list of possible causes: the mechanisms of failure. John Moreland was the first to describe a coherent system which needed only one simple addition to be complete: 1.) Prosthetic joint infection; 2.) Extensor disruption; 3.) Patella and malrotation; 4.) Loose; 5.) Component breakage; 6.) PP fracture; 7.) Poor motion; and 8.) Tibial femoral instability. Evaluation begins with the history, where 10 questions in particular are useful: 1.) What seems to be the problem? 2.) Was the “knee” ever successful after surgery? If there was never pain relief, is the current pain, the same or different? 3.) Standard pain quality questions - Location, duration, frequency, quality, exacerbating, ameliorating. 4.) Swelling? 5.) Stiffness? 6.) Giving way? 7.) Weakness? 8.) Things “just don't feel right”? 9.) Possible sepsis questions - Fever, chills, sources, primary TKA healing. 10.) Mood, social situation?. The physical exam should cover these ten points: 1.) Active extension; 2.) Rising from chair; 3.) Gait: hip, knee alignment, knee instability; 4.) Hip (internal rotation); 5.) Inspection; 6.) Tenderness; 7.) ROM; 8.) Stability (extension and 30–45 degrees flexion; 9.) Sitting on edge of exam table (knee at 90 degrees); and 10.) Step up on low stool (stair). Investigations include: 1.) ESR + CRP; 2.) CBC; 3.) HGB- anemia; 4.) Lymphocytes- nutrition; 5.) GGT- alcohol abuse; 6.) Albumen- nutrition; 7.) HbA1c- diabetic control. Imaging includes: 1.) Single leg weightbearing AP; 2.) Lateral; 3.) Merchant; 4.) Full length (hip-knee-ankle); 5.) AP pelvis; 6.) CT scan; and 7.) (Technitium bone scan)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 7 - 7
1 Jan 2016
Goto K Kitamura N Koichi S Yokota M Wada S Yasuda K
Full Access

Introduction. Modular stems are commonly used to improve fixation in revision total knee arthroplasty (TKA). Hybrid fixation, in which cement is placed around the metaphysical portion of the component combined with an uncemented diaphyseal modular stem, has potential advantages including ease of insertion, improved component alignment, and ease of removal if needed. The aim of this study was to evaluate clinical results of revision total knee arthroplasty with uncemented modular stems using a hybrid fixation technique with a minimum 5-year follow-up. Methods. 23 revision TKAs were performed in 21 patients with hybrid fixation using uncemented modular stems. 3 patients (3 knees) had died of causes unrelated to the index arthroplasty at the time of the study, and 1 patient (1 knee) was lost to the follow-up. The remaining 19 knees were clinically and radiographically evaluated for the present study. The average follow-up time was 9.5 years. The average age of the patients was 70.5 years at the time of the revision surgery. The average time between the primary and revision surgeries was 10.6 years. Results. The reasons for the revision of the 19 knees were aseptic loosening in 14 knees and breakage of polyethylene or implant in 5 knees. The mean postoperative range of motion was 110.2 degrees at the time of the most recent follow-up. The mean postoperative knee and function scores were 80.6 and 50.8, respectively. Periprosthetic radiolucencies were found adjacent to 2 tibial components and an asymptomatic cortical thickening around the end-of-stem was found in 1 tibial component. There were no intra- or postoperative complications resulting from the prosthesis implantation with this technique. Discussion. Revision TKA with hybrid fixation demonstrated excellent clinical results in terms of survival rate at a minimum 5-year follow-up. Although the ideal fixation of modular stems in revision TKA remains unclear, this study demonstrated that hybrid fïxation can be a viable option to provide durable fixation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2016
Arora B Shah N
Full Access

Background. Subvastus approach for Total Knee Arthropalsty (TKA) allows a faster recovery. It is traditionally not utilized for revision surgeries because of difficulty in exposure of the knee and eversion of the patella. It is considered to have limited indications. We hypothesized that revision TKA should not really pose a problem as the exposure gained is adequate with added advantage of preserving the extensor mechanism, thereby allowing faster functional recovery. We present an analysis of the use of subvastus approach for revision TKAs. Materials and methods. 50 patients (50 knees) 37 females + 13 males with mean age 68 years underwent revision total knee arthroplasty (TKA) by subvastus approach between January 2006 to January 2013. All patients were prospectively evaluated by pre- and postoperative Knee Society and function score. The average follow-up was 24 months (range from 1 to 3 years) with minimum 1 year follow-up. The indications for revisions were aseptic loosening (20 knees), infection (12 knees), instability (12 knees) and peri-prosthetic fractures (6 knees). Constrained condylar prosthesis (43 knees), hinged prosthesis (6 knees) and custom made prosthesis (1 knee) were fixed using the subvastus approach. Infected knees underwent one or two staged revisions. Results. The approach provided adequate exposure in all revisions. The average Knee Society score improved from 42 to 83 and the function score from 48 to 65. The complications included medial collateral ligament injury (one case), patellar tendon avulsion (one case) and mal-tracking patella (one case). Average hospital stay was 4 days. Average blood lose was 400 ml. Conclusion. Our results compare favourably with other reported series on revision TKA. The subvastus approach can be considered for revision TKAs


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 58 - 58
1 Dec 2015
Duijf S Telgt D Nijsse B Meis J Goosen J
Full Access

Prosthetic joint infections (PJI) caused by Streptococcus species are relatively common. The aim of our study was to assess outcome after treatment for early and late PJI with Streptococcus species after a follow-up of two years. For this study we retrospectively included all patients with primary or revision total knee arthroplasty (TKA) or total hip (THA) arthroplasty, a minimum of two periprosthetic tissue cultures positive for Streptococcus species and a minimum follow-up of one year. According to international guidelines patients were classified as having early or late PJI. All patients with an early PJI were treated according to a standard treatment protocol, i.e. debridement and retention of the prosthesis, followed by adequate antibiotic therapy. Patients with late PJI underwent a debridement followed by adequate antibiotic therapy or joint revision. Patients’ hospital records were reviewed and we evaluated the status of the original prosthesis after an infection. Forty cases were included; 24 early and 16 late PJI. For early PJI, open debridement was performed in all patients, after a mean of 19 (range: 9 – 80) days. At final follow-up 21 prostheses (88%) were still in situ and without clinical signs of infection. Eight cases (41%) of late PJI were successfully treated with debridement and retention. Nine patients (59%) underwent a one- or two-stage revision. At final follow-up 16 patients (100%) with late PJI had a prosthesis in situ. Streptococcus dysgalactiae species accounted for more than 50% of the early infections, followed by Streptococcus agalactiae with 30%. In case of PJI with Streptococcus species open debridement and retention of the prosthesis should be performed followed by adequate and long-term antibiotic treatment. As expected, the retention rate for early PJI is much higher than that for late PJI


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 68 - 68
1 Aug 2017
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating pre-operative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Large prosthetic augments (cones); 7) Massive structural allograft-prosthetic composites (APC); 8) Custom implants. Maximizing support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Pre-operative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the pre-operative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intra-operative findings such as occult fracture through deficient periprosthetic bone. Reconstruction of bone deficiency following removal of the failed implant is largely dictated by the location and extent of bone loss and the quality of bone that remains. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions the degree of implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects especially of the cavitary sort may be well managed with minimal constraint. Highly porous metal augments designed to reestablish metaphyseal support and function in the manner of a prosthetic structural graft have been introduced or are under development by several manufacturers. Published reports of short term experiences have been encouraging for both the tibial side and for femoral augmentation. It remains to be seen whether these implants will provide the desired longer term durability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 117 - 117
1 Mar 2017
Yu S Bolz N Buza J Saleh H Murphy H Rathod P Iorio R Schwarzkopf R Deshmukh A
Full Access

Introduction. Revision Total Knee Arthroplasty (TKA) is becoming increasingly prevalent as the number of TKA procedures grow in a younger, higher-demand population. Factors associated with patients requiring multiple revision TKAs are not yet well understood. The purpose of this study is to investigate the epidemiology of re-revision TKA, and identify risk factors that are associated with failure of re-revision TKA. Methods. A retrospective analysis was performed on 358 patients who underwent revision TKA at a single institution between 1/2012 and 12/2013. Patients who underwent revision knee arthroplasty two or more times were included. Patients were excluded if their indication for the first revision was periprosthetic joint infection (PJI). Patient demographics, surgical indications, revision details, and available follow-up information were collected. Re-revision failure was defined as the need for any additional operative intervention. A logistic regression analysis was performed to assess for significant predictors of re-revision failure. Results. A total of 66 re-revision TKA patients were included in this study. Mean age at re-revision was 60 (±11 years). There were 48 (73%) females. Mean BMI was 31.8 (±6.9). Median ASA level was 2 (40/59; 68%). Average follow up was 2.1 (±1.0) years, with 68% (45/66) of patients having greater than 2 year follow up (Table 1). The median number of revisions was 2 (range 2–11). The most common indication for re-revision was arthrofibrosis (15; 23%), followed by PJI (14; 21%) and aseptic component loosening (13; 20%). Among re-revision patients, the most common indication of the first revision was aseptic component loosening (17; 30%), followed by arthrofibrosis (16; 28%) and instability (9; 16%) (Table 2). Among the top four indications for re-revision, both the re-revision and initial revision indication were the same. Additionally, 42% of patients possessed the same indication for re-revision as the initial revision. The proportion of patients that had a lateral release performed in either the index procedure or initial revision was higher in re-revisions performed for patellar maltracking (p=0.013). There was a significantly increased risk of re-revision failure if the patient had a higher BMI (OR=1.22; p=0.006). Re-revision survival at 30 days was 92% (60/65), at 1 year was 81% (52/64), and at 2 years 73% (33/45). The indication history of re-revision failure is shown on Table 3. Discussion. Arthrofibrosis and PJI were the most common indications for re-revision. There was an increased risk of re-revision failure in patients with a higher BMI. It was common to have a re-revision TKA for the same indication as the initial revision. A better understanding of the indications and patient factors that are associated with re-revision failures can help align surgeon and patient expectations in this challenging population. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 66 - 66
1 Jul 2014
Abdel M
Full Access

Massive bone loss on both the femur and tibia during revision total knee arthroplasty (TKA) remains a challenging problem. Multiple solutions have been proposed for small osseous defects, including morselised cancellous bone grafting, small-fragment structural allograft, thicker polyethylene inserts, and the use of modular augments attached to revision prosthetic designs. Large osseous defects can be treated with structural allografts, impaction bone-grafting with or without mesh augmentation, custom prosthetic components, and specialised hinged knee components. The metaphyseal area of the distal femur and proximal tibia is a particularly attractive option during revision TKA given that it is usually undamaged and well-vascularised. While multiple reconstructive options have been recommended, porous tantalum metaphyseal cones have the advantage of improved biologic fixation because of their high porosity (75–80%), interconnected pore space, and low modulus of elasticity (3 MPa) similar to that of cancellous bone. Such features allow tantalum cones to fill bone defects while tolerating physiological loads. Indications for porous tantalum metaphyseal cones include patients with Anderson Orthopaedic Research Institute Type 2B or greater defects. The surgical technique is simpler than structural allograft reconstructions with decreased preparation time, resulting in a possible decrease in infection rates. The modularity of porous tantalum metaphyseal cones also allows the surgeon to choose a size and position that best fits the individual defect encountered. Moreover, tantalum cones can be used with several revision systems. Short-term clinical follow up indicates that porous tantalum metaphyseal cones effectively provide structural support with the potential for long-term biologic fixation and durable reconstructions


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 492 - 492
1 Dec 2013
Meftah M Ranawat A Ranawat CS
Full Access

Introduction:. Non-cemented, porous-coated metaphyseal sleeves have been designed to improve biologic fixation and stability in revision total knee arthroplasty (TKA) with major bone defects. The aim of this study was to evaluate the clinical results and osteointegration of these sleeves in major bone loss. Materials and Methods:. Between 2008 and 2011, 24 revision TKAs with major bone loss were reconstructed with non-cemented, porous-coated proximal sleeve (DePuy, Warsaw, IN). All patients were prospectively followed for a minimum of 2 years. Indications for use of sleeves were major metaphyseal tibial and femoral bone loss, younger age, and higher activity level. Osteointegration around the sleeves were classified as: . –. Grade 1: Complete osteointegration in all views without any demarcation. –. Grade 2: Sleeves that are not completely osteointegrated but they are stable. Grade 2A: Demarcation less than 2 mm on any view. Grade 2B: Demarcation more than 2 mm on any view . –. Grade 3: Sleeves that are not osteointegrated and unstable with evidence of subsidence. Grade 3A: Subsidence less than 2 mm on any view. Grade 3B: Subsidence more than 2 mm on any view. Results:. Mean range of motion and Knee Society Scores were 108 degrees and 92 respectively. 14 cases were revised for aseptic loosening and 10 cases for infection (which were treated with two stage revision arthroplasty). There was no malalignment, subsidence or re-revision at final follow-up. All sleeves were osteointegrated with majority grade 1 or 2a. Discussion and conclusion:. Short-term results of non-cemented metaphyseal sleeves in major bone loss for loosening of infection demonstrated excellent clinical results and osteointegration


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 149 - 149
1 May 2016
De Martino I Sculco P Galasso O Gasparini G
Full Access

Introduction. The optimal management of severe tibial and/or femoral bone loss in a revision total knee arthroplasty (TKA) has not been established. Reconstructive methods include structural or bulk allografts, impaction bone-grafting with or without mesh augmentation, custum prosthetic components, modular metal augmentations of prosthesis and tumor prosthesis. Recently metaphyseal fixation using porous tantalum cones (Zimmer, Warsaw, IN) has been proposed as alternative strategy for severe bone loss. Objectives. The purposes of this study were to determine the clinical and radiographic outcomes in patients who underwent revision knee arthroplasty with tantalum cones with a minimum of 5-year follow-up. Methods. From November 2005 to August 2008 a total of 26 porous tantalum metaphyseal cones were used to reconstruct severe tibial and/or femoral bone loss in 18 patients during revision TKA at a single institution. There were 12 females and 6 males with an average age of 73 years (range 55–84) at the time of revision. The mean clinical and radiographic follow-up was 6.3 years (range, 5–8). The reasons for revision were aseptic loosening (5 cases) and deep infection (13 cases). A Two stage procedure was used in all septic cases. According to the Anderson Orthopaedic Reseach Institute (AORI) bone defects classification all femoral and tibial defects were rated 2B and 3 (3 T2b, 9 T3, 3 F2b and 10 F3). A femoral cone was inserted in 6 patients, a tibial cone was inserted in 5, a double cone in 6 (femoral and tibial), and a triple cone in 1 (1 femoral and 2 tibial). A constrained condylar implant (LCCK, Zimmer, Warsaw) was inserted in 6 patients and a rotating hinge knee implants (RHK, Zimmer, Warsaw, IN) in 12 pateints. All patients were prospectively followed for clinical and radiographic evaluation preoperatively and postoperatively at 1, 3, 6 months, one year and yearly thereafter. Results. Knee Society knee scores improved from a mean of 31.3 points before surgery to 76.7 points at latest followup (p < 0.001). Knee Society function scores improved from a mean of 21.7 points before surgery to 65.4 points at latest followup (p < 0.001). The average flexion contracture was 6° and the average flection was 88°. At the time of the latest follow-up the average flexion contraction was 3° and the average flexion was 105°. No radiolucent lines were seen between the cones and the adjacent tibial and femoral bone at the latest follow-up. There was no evidence of loosening or migration of any implant at the time of the final follow-up. There have been two reoperations for recurrent infection (11%). Conclusions. Our experience demonstrates excellent clinical and radiographic mid-term outcomes and confirms that metaphyseal fixation with porous tantalum cones can be achieved. Long-term follow up and comparative studies are necessary