Abstract
Introduction
Modular stems are commonly used to improve fixation in revision total knee arthroplasty (TKA). Hybrid fixation, in which cement is placed around the metaphysical portion of the component combined with an uncemented diaphyseal modular stem, has potential advantages including ease of insertion, improved component alignment, and ease of removal if needed. The aim of this study was to evaluate clinical results of revision total knee arthroplasty with uncemented modular stems using a hybrid fixation technique with a minimum 5-year follow-up.
Methods
23 revision TKAs were performed in 21 patients with hybrid fixation using uncemented modular stems. 3 patients (3 knees) had died of causes unrelated to the index arthroplasty at the time of the study, and 1 patient (1 knee) was lost to the follow-up. The remaining 19 knees were clinically and radiographically evaluated for the present study. The average follow-up time was 9.5 years. The average age of the patients was 70.5 years at the time of the revision surgery. The average time between the primary and revision surgeries was 10.6 years.
Results
The reasons for the revision of the 19 knees were aseptic loosening in 14 knees and breakage of polyethylene or implant in 5 knees. The mean postoperative range of motion was 110.2 degrees at the time of the most recent follow-up. The mean postoperative knee and function scores were 80.6 and 50.8, respectively. Periprosthetic radiolucencies were found adjacent to 2 tibial components and an asymptomatic cortical thickening around the end-of-stem was found in 1 tibial component. There were no intra- or postoperative complications resulting from the prosthesis implantation with this technique.
Discussion
Revision TKA with hybrid fixation demonstrated excellent clinical results in terms of survival rate at a minimum 5-year follow-up. Although the ideal fixation of modular stems in revision TKA remains unclear, this study demonstrated that hybrid fïxation can be a viable option to provide durable fixation.