Advertisement for orthosearch.org.uk
Results 1 - 50 of 9404
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 68 - 68
1 Dec 2021
Bandeira R Bassetti B Mara T de Araujo ROD Matos AP Silva RM Salles M
Full Access

Aim. Infection is one of the worst complications following total joint arthroplasty, which is often associated with significant morbidity. Currently, due to the global burden of multidrug-resistant Gram-negative bacteria (MDR-GNB) infections, few multicentre studies have described a microbiological shift from Gram-positive cocci (GPC) towards MDR-GNB PJI (prosthetic joint infection). Additionally, the emergence of MDR-GNB impacts the therapeutic options and may increase the rate of PJI treatment failure. The purpose of the present study was to describe the predisposing factors associated to failure of treatment in an orthopaedic reference hospital in Brazil from 2014 through 2019. Method. Retrospective case-control analysis of patients treated for MDR-GNB PJI over a five-year period. Data were collected from medical, surgical and laboratory records. PJI were defined according the current MSIS criteria. MDR was defined as non-susceptibility to at least one agent in three or more antimicrobial categories. Patients with PJI with at least two positive tissue cultures for MDR-GNB were selected. The control group was patient with PJI caused by multisensitive organism (GNB or GPC). Absence of signs and symptoms of infection during the follow-up period was defined as cure. Definition of failure: death, need for another course of antibiotic, or the need for another surgical procedure to control the infectious site (relapse). Results. A total of 104 patients were selected, 59 patients in the MDR-GNB PJI group and 44 in the control group. Two outcomes were compared: cure or failure. The overall 1-year survival rate was 65.3% with the median survival time being 207.08 days. In the MDR-BGN infection group the 1-year survival rate was 59.3% and the average time of survival was 141.14 days. In contrast, in the Control group the 1-year survival rate was 73.8% with an average survival time of 230.29 days (p = 0.023). HR: 2.447, IC 1.099–5.448. The independent variables in the multivariate analysis associated to treatment failure were MDR-BGN infection (p = 0.023) HR 2,447 IC 1,099 –5,448, revision surgery (p = 0.042) HR 2,027 IC: 2,027–4,061, presence of comorbidities (p = 0.048) HR 2,508 IC: 0,972- 6,469 and previous antimicrobial use in the last 3 months (p = 0.022). HR 2,132 IC: 1,096- 4,149. Conclusions. GNB-MDR PJI increases approximately 2.5 times the chance of unfavourable outcome such as death and infectious relapse compared to infections with other multisensitive microorganism


Bone & Joint Open
Vol. 3, Issue 5 | Pages 359 - 366
1 May 2022
Sadekar V Watts AT Moulder E Souroullas P Hadland Y Barron E Muir R Sharma HK

Aims. The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. Methods. We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture. Results. There were 244 frames (230 patients) included in the analyses, of which 90 were Ilizarov type frames and 154 were hexapods. There were 149 frames which underwent single-stage reloading and 95 frames which underwent a two-stage reloading protocol. Mechanical failure occurred after frame removal in 13 frames (5%), which suffered refracture. There were no cases of change in alignment. There was no difference between refracture patients who underwent single-stage or two-stage reloading protocols (p = 0.772). In all, 14 patients had failure prevented through identification with the reloading protocol. Conclusion. Our reloading protocol is a simple and effective way to confirm the timing of frame removal and minimize the rate of mechanical failure. Similar failure rates occurred between patients undergoing single-stage and two-stage reloading protocols. If the surgeon is confident with clinical and radiological assessment, it may be possible to progress directly to stage two and decrease frame time and patient morbidity. Cite this article: Bone Jt Open 2022;3(5):359–366


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 109 - 109
1 Mar 2017
Yokhana S Bergum C Markel D
Full Access

Background. Total knee prostheses are continually being redesigned to improve performance, longevity and closer mimic kinematics of the native knee. Despite continued improvements, all knee implants even those with proven design features, have failures. We identified a cohort of patients with isolated tibial component failures that occurred in a popular and successful knee system. Our purpose was to (1) characterize the observed radiographic failure pattern; (2) investigate the biologic response that may contribute to the failure; and (3) to determine if the failure mechanism was of a biological or a mechanical nature. Methods. Twenty-one knees from 19 patients met the inclusion criteria of having isolated tibial component failure in a commonly used knee implant system. Radiographs from the primary and revision knee surgery were analyzed for implant positioning and failure pattern, respectively. Inflammatory biomarkers IL-1β, IL-6 and TNF-α were available in 16/21 knees and peripheral CD14. +. /16. +. monocytes were measured in 10 of the above mentioned 16 knee revisions. Additionally, white blood cell (WBC) count, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were measured to rule out infection as the cause of the cytokine upregulation. Results. Radiograph findings demonstrated that all of the 21 tibial components were implanted in either neutral or 2–3° varus position, none of the revisions were implanted in valgus (figure 1). All tibias showed obvious radiographic loosening and failed into varus. The inflammatory biomarkers IL-1b, IL-6, & TNF-a were negative. WBC, ESR, CRP were normal. Peripheral CD14+/16+ and total CD16+ monocytesmeasurements were consistent with previous findings of patients with osteoarthritis (figure 2). Conclusions. The findings supported a mechanical failure mechanism rather than that of a wear debris induced inflammatory pattern. The loosening, collapse and debonding from the cement may have been related to the implantation technique, stresses due to rotational freedom of the implant, or patient characteristics/behavior. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 97 - 97
1 May 2012
Waller C
Full Access

Several attempts have been made to treat medial compartment OA of the knee with mobile spacers. All have met with dismal failure. This presentation explores the history of attempts to treat OA in the younger knee with mobile spacers and explains why they were all doomed to fail. Sources of information for this presentation include the published peer reviewed literature, publically available documents, and an insiders view of some of the failed attempts to solve the problem of medial compartment OA with mobile spacers. All attempts to treat medial compartment OA of the knee with mobile spacers have failed. The unispacer has been a failure with a 60% revision rate at three years. The ABS intercushion had a 100% revision rate at one year and in many cases caused permanent damage to the host knees. The Salucartilage spacer was implanted in one patient only and failed within 48 hours. Mobile spacers do not work, are never likely to work, and are not indicated for the treatment of medial compartment osteoarthritis of the knee


Bone & Joint Research
Vol. 13, Issue 5 | Pages 201 - 213
1 May 2024
Hamoodi Z Gehringer CK Bull LM Hughes T Kearsley-Fleet L Sergeant JC Watts AC

Aims. The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA). Methods. Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used. Results. A total of 19 studies met the inclusion criteria, investigating 28 possible prognostic factors. Most QUIPS domains (84%) were rated as moderate to high risk of bias. The quality of the evidence was low or very low for all prognostic factors. In low-quality evidence, prognostic factors with consistent associations with failure of TEA in more than one study were: the sequelae of trauma leading to TEA, either independently or combined with acute trauma, and male sex. Several other studies investigating sex reported no association. The evidence for other factors was of very low quality and mostly involved exploratory studies. Conclusion. The current evidence investigating the prognostic factors associated with failure of TEA is of low or very low quality, and studies generally have a moderate to high risk of bias. Prognostic factors are subject to uncertainty, should be interpreted with caution, and are of little clinical value. Higher-quality evidence is required to determine robust prognostic factors for failure of TEA. Cite this article: Bone Joint Res 2024;13(5):201–213


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims. Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial. Methods. The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival. Results. A total of 407 patients who underwent UKA were included in the study. The mean age of patients was 61.8 years, and the mean follow-up period of the patients was 91.7 months. The mean Knee Society Score (KSS) preoperatively and at the last follow-up were 64.2 and 89.7, respectively (p = 0.001). Overall, 28 patients (6.9%) with UKA underwent revision due to prosthesis loosening (16 patients), dislocation (eight patients), and persistent pain (four patients). Cox proportional hazards model analysis identified malposition of the prostheses as a high-risk factor for UKA failure (p = 0.007). Kaplan-Meier analysis revealed that the five-year survival rate of the group with malposition was 85.1%, which was significantly lower than that of the group with normal position (96.2%; p < 0.001). Conclusion. UKA constitutes an effective method for treating anteromedial knee OA, with an excellent five-year survival rate. Aseptic loosening caused by prosthesis malposition was identified as the main cause of UKA failure. Surgeons should pay close attention to prevent the potential occurrence of this problem. Cite this article: Bone Jt Open 2023;4(12):914–922


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 30 - 30
2 May 2024
Dhesi E Salih S Tomlinson R Salih S
Full Access

Polymethylmethacrylate (PMMA) bone cement is strong in compression, however it tends to fail under torsion. Sufficient pressurisation and subsequent interdigitation between cement and bone are critical for the mechanical interlock of cemented orthopaedic implants, and an irregular surface on the acetabular cup is necessary for reasonable fixation at the cup-cement interface. There is limited literature investigating discrepancies in the failure mechanisms of cemented all-polyethylene acetabular cups with and without cement spacers, under torsional loading. In vitro experimental comparison of three groups of polyethylene acetabular prosthesis (PAP) cemented into prepared sawbone hemipelvises:. * PAP without PMMA spacers maintaining an equal cement mantle circumferentially. (Group 1 n=3). * PAP without PMMA spacers cemented deliberately ‘bottoming-out’ the implant within the acetabulum. (Group 2 n=3). * PAP with PMMA spacers. (Group 3 n=3). The constructs were tested to torstional failure on a custom designed setup, and statistical analysis done by a one-way ANOVA and Tukey-Welsh test. Group 3 demonstrated superior torsional resistance with a statistically significant torque of 145Nm (SD±12Nm) at failure, compared to group 2 (109Nm, SD±7Nm) and group 1 (99Nm, SD±8Nm). Group 3 experienced failure predominantly at the bone-cement interface, in contrast, Groups 1 and 2 exhibited failure predominantly at the cup-cement interface. There was no significant difference between Group 1 and 2. Qualitative analysis of the failure mode indicates the efficient redistribution of stress throughout the cement mantle, consistent with the greater uniformity of cement. PMMA spacers increase the resistance to torsional failure at the implant-cement interface. Acetabular components without spacers (Groups 1 and 2) failed at the implant-cement interface before the cement-bone interface, at a statistically significantly lower level of torque to failure. Although the PMMA spacers may reduce cement interdigitation at the cement-bone interface the torsional forces required to fail are likely supraphysiological


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1294 - 1302
1 Dec 2023
Knoll L Steppacher SD Furrer H Thurnheer-Zürcher MC Renz N

Aims. A higher failure rate has been reported in haematogenous periprosthetic joint infection (PJI) compared to non-haematogenous PJI. The reason for this difference is unknown. We investigated the outcome of haematogenous and non-haematogenous PJI to analyze the risk factors for failure in both groups of patients. Methods. Episodes of knee or hip PJI (defined by the European Bone and Joint Infection Society criteria) treated at our institution between January 2015 and October 2020 were included in a retrospective PJI cohort. Episodes with a follow-up of > one year were stratified by route of infection into haematogenous and non-haematogenous PJI. Probability of failure-free survival was estimated using the Kaplan-Meier method, and compared between groups using log-rank test. Univariate and multivariate analysis was applied to assess risk factors for failure. Results. A total of 305 PJI episodes (174 hips, 131 knees) were allocated to the haematogenous (n = 146) or the non-haematogenous group (n = 159). Among monomicrobial infections, Staphylococcus aureus was the dominant pathogen in haematogenous PJI (76/140, 54%) and coagulase-negative staphylococci in non-haematogenous PJI (57/133, 43%). In both groups, multi-stage exchange (n = 55 (38%) in haematogenous and n = 73 (46%) in non-haematogenous PJI) and prosthesis retention (n = 70 (48%) in haematogenous and n = 48 (30%) in non-haematogenous PJI) were the most common surgical strategies. Median duration of antimicrobial treatment was 13.5 weeks (range, 0.5 to 218 weeks) and similar in both groups. After six years of follow-up, the probability of failure-free survival was significantly lower in haematogenous compared to non-haematogenous PJI (55% vs 74%; p = 0.021). Infection-related mortality was significantly higher in haematogenous than non-haematogenous PJI (7% vs 0% episodes; p = 0.001). Pathogenesis of failure was similar in both groups. Retention of the prosthesis was the only independent risk factor for failure in multivariate analysis in both groups. Conclusion. Treatment failure was significantly higher in haematogenous compared to non-haematogenous PJI. Retention of the prosthesis was the only independent risk factor for failure in both groups. Cite this article: Bone Joint J 2023;105-B(12):1294–1302


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim. Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs. Method. Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients. Results. A total of 40 patients with RA and 80 controls without RA were included. Treatment failure occurred in 65% patients with RA compared to 45% for controls (p= .052). 68% of patients with RA used immunosuppressive drugs at time of PJI diagnosis. The use or continuation of immunosuppressive drugs in PJI was not associated with a higher failure rate; neither were the duration of symptoms and causative microorganism. The time between implantation of the prosthetic joint and diagnosis of infection was longer in RA patients: median 110 (IQR 41-171) vs 29 months (IQR 7.5–101.25). Exchange of mobile components was associated with a lower risk of treatment failure (HR 0.489, 95% CI 0.242–0.989, p-value .047). Conclusions. The use of immunosuppressive drugs does not seem to be associated with a higher failure rate in patients with RA. Mobile exchange in RA patients is associated with a lower risk of failure. This might be due to the significantly older age of the prosthesis in RA patients. Future studies are needed to explore these associations and its underlying pathogenesis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 60 - 60
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

Meniscal repairs are commonly performed during anterior cruciate ligament (ACL) reconstruction. This study aimed to identify the risk factors for meniscal repair failure following concurrent primary ACL reconstruction. Primary ACL reconstructions with a concurrent repair of a meniscal tear recorded in the New Zealand ACL Registry between April 2014 and December 2018 were analyzed. Meniscal repair failure was defined as a patient who underwent subsequent meniscectomy, and was identified after cross-referencing data from the ACL Registry with the national database of the Accident Compensation Corporation (ACC). Multivariate Cox regression was performed to produce hazard ratios (HR) with 95% confidence intervals (CI) to identify the patient and surgical risk factors for meniscal repair failure. 2041 meniscal repairs were analyzed (medial = 1235 and lateral = 806). The overall failure rate was 9.4% (n = 192). Failure occurred in 11.1% of medial (137/1235) and 6.8% of lateral (55/806) meniscal repairs. The risk of medial failure was higher with hamstring tendon autografts (adjusted HR = 2.00, 95% CI 1.23 – 3.26, p = 0.006) and in patients with cartilage injury in the medial compartment (adjusted HR = 1.56, 95% CI 1.09 – 2.23, p = 0.015). The risk of lateral failure was higher when the procedure was performed by a surgeon with an annual case volume of less than 30 ACL reconstructions (adjusted HR = 1.92, 95% CI 1.10 – 3.33, p = 0.021). Age, gender, time from injury-to-surgery and femoral tunnel drilling technique did not influence the risk of meniscal repair failure. When repairing a meniscal tear during ACL reconstruction, the use of a hamstring tendon autograft or the presence of cartilage injury in the medial compartment increases the risk of medial meniscal repair failure. Lower surgeon case volume increases the risk of lateral meniscal repair failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 57 - 57
1 Dec 2022
Gazendam A Ekhtiari S Wood T Petruccelli D Tushinski D Winemaker MJ de Beer J
Full Access

The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the long-term survival of this stem and analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. A retrospective review was undertaken of all patients who received a primary total hip arthroplasty with an Accolade® TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to minimize loss to follow-up. Survivorship analysis was performed with use of the Kaplan-Meier curves to determine the overall and aseptic survival rates at final follow-up. Patient and implant factors commonly associated with aseptic failure were extracted and Cox proportional hazards model was used. A consecutive series of 2609 unilateral primary THA patients implanted with an Accolade®TMZF femoral hip stem were included. Mean time from primary surgery was 12.4 years (range 22 days to 19.5 years). Cumulative survival was 96.1% ± 0.2 at final follow-up. One hundred and seven patients underwent revision surgery with aseptic loosening of the femoral component was the most common cause of aseptic failure in this cohort (33/2609, 1.3%). Younger age and larger femoral head offset were independent risk factors for aseptic failure. To our knowledge, this is the largest series representing the longest follow-up of this taper-wedge cementless femoral implant. Despite early concerns, the Accolade® TMZF stem has excellent survivorship in this cohort. Trunnionosis as a recognized cause for revision surgery was rare. Younger age and larger femoral head offset were independent risk factors for aseptic failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 11 - 11
1 Dec 2022
Tolgyesi A Huang C Akens M Hardisty M Whyne C
Full Access

Bone turnover and the accumulation of microdamage are impacted by the presence of skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. The present study aims to establish a preliminary understanding of microdamage accumulation and load to failure in osteolytic vertebrae following stereotactic body radiotherapy (SBRT), zoledronic acid (ZA), or docetaxel (DTX) treatment. Twenty-two six-week old athymic female rats (Hsd:RH-Foxn1rnu, Envigo, USA) were inoculated with HeLa cervical cancer cells through intracardiac injection (day 0). Institutional approval was obtained for this work and the ARRIVE guidelines were followed. Animals were randomly assigned to four groups: untreated (n=6), spine stereotactic body radiotherapy (SBRT) administered on day 14 (n=6), zoledronic acid (ZA) administered on day 7 (n=5), and docetaxel (DTX) administered on day 14 (n=5). Animals were euthanized on day 21. T13-L3 vertebral segments were collected immediately after sacrifice and stored in −20°C wrapped in saline soaked gauze until testing. µCT scans (µCT100, Scanco, Switzerland) of the T13-L3 segment confirmed tumour burden in all T13 and L2 vertebrae prior to testing. T13 was stained with BaSO. 4. to label microdamage. High resolution µCT scans were obtained (90kVp, 44uA, 4W, 4.9µm voxel size) to visualize stain location and volume. Segmentations of bone and BaSO. 4. were created using intensity thresholding at 3000HU (~736mgHA/cm. 3. ) and 10000HU (~2420mgHA/cm. 3. ), respectively. Non-specific BaSO. 4. was removed from the outer edge of the cortical shell by shrinking the segmentation by 105mm in 3D. Stain volume fraction was calculated as the ratio of BaSO. 4. volume to the sum of BaSO. 4. and bone volume. The L1-L3 motion segments were loaded under axial compression to failure using a µCT compatible loading device (Scanco) and force-displacement data was recorded. µCT scans were acquired unloaded, at 1500µm displacement and post-failure. Stereological analysis was performed on the L2 vertebrae in the unloaded µCT scans. Differences in mean stain volume fraction, mean load to failure, and mean bone volume/total volume (BV/TV) were compared between treatment groups using one-way ANOVAs. Pearson's correlation between stain volume fraction and load to failure by treatment was calculated using an adjusted load to failure divided by BV/TV. Stained damage fraction was significantly different between treatment groups (p=0.0029). Tukey post-hoc analysis showed untreated samples to have higher stain volume fraction (16.25±2.54%) than all treatment groups (p<0.05). The ZA group had the highest mean load to failure (195.60±84.49N), followed by untreated (142.33±53.08N), DTX (126.60±48.75N), and SBRT (95.50±44.96N), but differences did not reach significance (p=0.075). BV/TV was significantly higher in the ZA group (49.28±3.56%) compared to all others. The SBRT group had significantly lower BV/TV than the untreated group (p=0.018). Load divided by BV/TV was not significantly different between groups (p=0.24), but relative load to failure results were consistent (ZA>Untreated>DTX>SBRT). No correlations were found between stain volume fraction and load to failure. Focal and systemic cancer treatments effect microdamage accumulation and load to failure in osteolytic vertebrae. Current testing of healthy controls will help to further separate the effects of the tumour and cancer treatments on bone quality


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 15 - 15
1 Dec 2022
Tolgyesi A Huang C Akens M Hardisty M Whyne C
Full Access

Bone turnover and the accumulation of microdamage are impacted by the presence of skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. The present study aims to establish a preliminary understanding of microdamage accumulation and load to failure in osteolytic vertebrae following stereotactic body radiotherapy (SBRT), zoledronic acid (ZA), or docetaxel (DTX) treatment. Twenty-two six-week old athymic female rats (Hsd:RH-Foxn1rnu, Envigo, USA) were inoculated with HeLa cervical cancer cells through intracardiac injection (day 0). Institutional approval was obtained for this work and the ARRIVE guidelines were followed. Animals were randomly assigned to four groups: untreated (n=6), spine stereotactic body radiotherapy (SBRT) administered on day 14 (n=6), zoledronic acid (ZA) administered on day 7 (n=5), and docetaxel (DTX) administered on day 14 (n=5). Animals were euthanized on day 21. T13-L3 vertebral segments were collected immediately after sacrifice and stored in −20°C wrapped in saline soaked gauze until testing. µCT scans (µCT100, Scanco, Switzerland) of the T13-L3 segment confirmed tumour burden in all T13 and L2 vertebrae prior to testing. T13 was stained with BaSO. 4. to label microdamage. High resolution µCT scans were obtained (90kVp, 44uA, 4W, 4.9µm voxel size) to visualize stain location and volume. Segmentations of bone and BaSO. 4. were created using intensity thresholding at 3000HU (~736mgHA/cm. 3. ) and 10000HU (~2420mgHA/cm. 3. ), respectively. Non-specific BaSO. 4. was removed from the outer edge of the cortical shell by shrinking the segmentation by 105mm in 3D. Stain volume fraction was calculated as the ratio of BaSO. 4. volume to the sum of BaSO. 4. and bone volume. The L1-L3 motion segments were loaded under axial compression to failure using a µCT compatible loading device (Scanco) and force-displacement data was recorded. µCT scans were acquired unloaded, at 1500µm displacement and post-failure. Stereological analysis was performed on the L2 vertebrae in the unloaded µCT scans. Differences in mean stain volume fraction, mean load to failure, and mean bone volume/total volume (BV/TV) were compared between treatment groups using one-way ANOVAs. Pearson's correlation between stain volume fraction and load to failure by treatment was calculated using an adjusted load to failure divided by BV/TV. Stained damage fraction was significantly different between treatment groups (p=0.0029). Tukey post-hoc analysis showed untreated samples to have higher stain volume fraction (16.25±2.54%) than all treatment groups (p<0.05). The ZA group had the highest mean load to failure (195.60±84.49N), followed by untreated (142.33±53.08N), DTX (126.60±48.75N), and SBRT (95.50±44.96N), but differences did not reach significance (p=0.075). BV/TV was significantly higher in the ZA group (49.28±3.56%) compared to all others. The SBRT group had significantly lower BV/TV than the untreated group (p=0.018). Load divided by BV/TV was not significantly different between groups (p=0.24), but relative load to failure results were consistent (ZA>Untreated>DTX>SBRT). No correlations were found between stain volume fraction and load to failure. Focal and systemic cancer treatments effect microdamage accumulation and load to failure in osteolytic vertebrae. Current testing of healthy controls will help to further separate the effects of the tumour and cancer treatments on bone quality


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 12 - 12
1 Oct 2022
Fes AF Leal AC Alier A Pardos SL Redó MLS Verdié LP Diaz SM Pérez-Prieto D
Full Access

Aim. The most frequent mechanical failure in the osteosynthesis of intertrochanteric fractures is the cut-out. Fracture pattern, reduction quality, tip-apex distance or the position of the cervico-cephalic screw are some of the factors that have been associated with higher cut-out rates. To date, it has not been established whether underlying bacterial colonization or concomitant infection may be the cause of osteosynthesis failure in proximal femur fractures (PFF). The primary objective of this study is to assess the incidence of infection in patients with cut-out after PFF osteosynthesis. Method. Retrospective cohort study on patients with cut-out after PFF osteosynthesis with endomedullary nail, from January 2007 to December 2020. Demographic data of patients (such as sex, age, ASA), fracture characteristics (pattern, laterality, causal mechanism) and initial surgery parameters were collected (time from fall to intervention, duration of surgery, intraoperative complications). Radiographic parameters were also analyzed (tip-apex distance and Chang criteria). In all cut-out cases, 5 microbiological cultures and 1 anatomopathological sample were taken and the osteosynthesis material was sent for sonication. Fracture-related infection (FRI) was diagnosed based on Metsemakers et al (2018) and McNally et al (2020) diagnostic criteria. Results. Of the 67 cut-out cases, 16 (23.9%) presented clinical, analytical or microbiological criteria of infection. Of these sixteen patients, only in 3 of them the presence of an underlying infection was suspected preoperatively. A new osteosynthesis was performed in 24 cases (35.8%) and a conversion to arthroplasty in the remaining 43 (64.2%). A comparative analysis was performed between cases with and without infection. The groups were comparable in terms of demographic data and postoperative radiological data (using Chang criteria and tip-apex distance). Patients with underlying infection had a higher rate of surgical wound complication (56.3% vs 22%, p = 0.014), higher rates of leukocytes counts (11.560 vs 7.890, p = 0.023) and time to surgery (5.88 vs 3.88 days, p = 0.072). Conclusions. One out of four osteosynthesis failure in PFF is due to underlying FRI and in almost 20% were not unsuspected before surgery. In PFF osteosynthesis failures, underlying infection should be taken into account as a possible etiological factor and thus a preoperative and intraoperative infection study should be always performed


Bone & Joint Open
Vol. 3, Issue 6 | Pages 485 - 494
13 Jun 2022
Jaubert M Le Baron M Jacquet C Couvreur A Fabre-Aubrespy M Flecher X Ollivier M Argenson J

Aims. Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors. Methods. We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's t-test, Mann-Whitney U test, and Fisher's exact test. Results. Our staged exchange practice shows poor results, which means a 42% mechanical spacer failure rate, and a 20% recurrent infection rate over the two years average follow-up period. Moreover, we found a high rate of spacer dislocation (23%) and a low rate of spacer fracture (8%) compared to the previous literature. Our findings stress that the majority of spacer complications and failures is reflecting a population with high comorbid burden, highlighted by the American Society of Anesthesiology grade, Charlson Comorbidity Index, and Lee score associations, as well as the cardiac, pulmonary, kidney, or hepatic chronic conditions. Conclusion. Our experience of a two-stage hip exchange revision noted important complication rates associated with high failure rates of polymethylmethacrylate spacers. These findings must be interpreted in the light of the patient’s comorbidity profiles, as the elective population for staged exchange has an increasing comorbid burden leading to poor results. In order to provide better results for this specific population, our conclusion suggests that comparative strategy studies are required to improve our therapeutic indication. Cite this article: Bone Jt Open 2022;3(6):485–494


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 17 - 17
4 Jun 2024
Najefi AA Chan O Zaidi R Hester T Kavarthapu V
Full Access

Introduction. Surgical reconstruction of deformed Charcot feet carries high risk of non-union, metalwork failure and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions. Methods. We retrospectively analysed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between 2007 and 2019 in our unit. Patient demographics, co-morbidities, weightbearing status and post-operative complications were noted. Metalwork breakage, non-union, deformity recurrence, concurrent midfoot reconstruction and the measurements related to intramedullary nail were also recorded. Results. There were 70 patients with mean follow up of 50±26 months. Seventy-two percent were fully weightbearing at 1 year post-operatively. The overall union rate was 83%. Age, BMI, HbA1c and peripheral vascular disease did not affect union. The ratio of nail diameter and isthmus was greater in the united compared to the non-united group (0.90±0.06 and 0.86±0.09, respectively; p = 0.03). Supplemental compression devices were used for 33% of those in the united compared to 8% in the non-united group (p = 0.04). All patients in the non-union group did not have a miss-a-nail screw. Metalwork failure was seen in 13 patients(19%). There was a significantly greater distal screw metalwork failure in those with supplementary bridging of tibia to midfoot (23% vs. 3%; p = 0.001). An intact medial malleolus was found more frequently in those with intact metalwork (77% vs. 54%, respectively; p = 0.02) and those with union (76% vs. 50%; p = 0.02). Broken metalwork occurred more frequently in patients with non-unions (69% vs. 8%; p < 0.001) and deformity recurrence (69% vs. 9%; p < 0.001). Conclusion. Satisfactory clinical and radiographic outcomes occur in over 80% of patients. Union after hindfoot reconstruction occurs more frequently with an isthmic fit of the intramedullary nail, supplementary compression and miss-a-nail screws. An intact medial malleolus is protective against non-union and metalwork failure. Broken metalwork is linked to deformity recurrence and non-union


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims. Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions. Methods. We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded. Results. There were 70 patients with mean follow-up of 54 months (SD 26). Overall, 51 patients (72%) and 52 patients (74%) were fully weightbearing at one year postoperatively and at final follow-up, respectively. The overall hindfoot union rate was 83% (58/70 patients). Age, BMI, glycated haemoglobin, and prior revascularization did not affect union. The ratio of nail diameter and isthmus was greater in the united compared to the nonunited group (0.90 (SD 0.06) and 0.86 (SD 0.09), respectively; p = 0.034). In those with a supplementary hindfoot compression screw, there was a 95% union rate (19/20 patients), compared to 78% in those without screws (39/50 patients; p = 0.038). All patients with a miss-a-nail hindfoot compression screw went on to union. Hindfoot metalwork failure was seen in 13 patients (19%). An intact medial malleolus was found more frequently in those with intact metalwork ((77% (44/57 patients) vs 54% (7/13 patients); p = 0.022) and in those with union ((76% (44/58 patients) vs 50% (6/12 patients); p = 0.018). Broken metalwork occurred more frequently in patients with nonunions (69% (9/13 patients) vs 9% (5/57 patients); p < 0.001) and midfoot deformity recurrence (69% (9/13 patients) vs 9% (5/57 patients); p < 0.001). Conclusion. Rates of hindfoot union and intact metalwork were noted in over 80% of patients. Union after hindfoot reconstruction occurs more frequently with an isthmic fit of the intramedullary nail and supplementary hindfoot screws. An intact medial malleolus is protective against nonunion and hindfoot metalwork failure. Cite this article: Bone Joint J 2022;104-B(6):703–708


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 4 - 4
10 May 2024
Hoffman T Knudsen J Jesani S Clark H
Full Access

Introduction. Debridement, antibiotics irrigation and implant retention (DAIR) is a common management strategy for hip and knee prosthetic joint infections (PJI). However, failure rates remain high, which has led to the development of predictive tools to help determine success. These tools include KLIC and CRIME80 for acute-postoperative (AP) and acute haematogenous (AH) PJI respectively. We investigated whether these tools were applicable to a Waikato cohort. Method. We performed a retrospective cohort study that evaluated patients who underwent DAIR between January 2010 and June 2020 at Waikato Hospital. Pre-operative KLIC and CRIME80 scores were calculated and compared to success of operation. Failure was defined as: (i) need for further surgery, (ii) need for suppressive antibiotics, (iii) death due to the infection. Logistic regression models were used to calculate the area under the curve (AUC). Results. 117 eligible patients underwent DAIR, 53 in the AP cohort and 64 in the AH cohort. Failure rate at 2 years post-op was 43% in the AP cohort and 59% in the AH cohort. In the AP cohort a KLIC score of <4 had a DAIR failure rate of 28.6%, while those who scored ³4 had a failure rate of 72.2% (p=0.002). In the AH cohort a CRIME80 score of <3 had a DAIR failure rate of 48% while those who scored ³3 had a 100% failure rate (p<0.001). Discussion. This study represents the first external validation of the KLIC and CRIME80 scores for predicting DAIR failure in an Australasian population. The results indicate that both KLIC and CRIME80 scoring tools are valuable aids for the clinician seeking to determine the optimal management strategy in patients with AP or AH PJI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 100 - 100
4 Apr 2023
Lu V Zhang J Zhou A Thahir A Krkovic M
Full Access

Fracture related infections (FRI) are debilitating complications of musculoskeletal trauma surgery that can result in permanent functional loss or amputation. This study aims to determine risk factors associated with FRI treatment failure, allowing clinicians to optimise them prior to treatment and identify patients at higher risk. A major trauma centre database was retrospectively reviewed over a six-year period. Of the 102 patients identified with a FRI (66 male, 36 female), 29.4% (n=30) had acute infections (onset <6 weeks post-injury), 34.3% (n=35) had an open fracture. Open fractures were classified using Gustilo-Anderson (GA) classification (type 2:n=6, type 3A:n=16, type 3B:n=10, type 3C:n=3). Patients with periprosthetic infections of the hip and knee joint, those without prior fracture fixation, soft tissue infections, diabetic foot ulcers, pressure sore infections, patients who died within one month of injury, <12 months follow-up were excluded. FRI treatment failure was defined as either infection recurrence, non-union, or amputation. Lifestyle, clinical, and intra-operative data were documented via retrospective review of medical records. Factors with a P-value of p<0.05 in univariate analysis were included in a stepwise multivariate logistic regression model. FRI treatment failure was encountered in 35.3% (n=36). The most common FRI site was the femoral shaft (16.7%; n=17), and 15.7% (n=16) presented with signs of systemic sepsis. 20.6% (n=21) had recurrent infection, 9.8% (n=10) had non-union, and 4.9% (n=5) required an amputation. The mean age at injury was 49.71 years old. Regarding cardiovascular risk factors, 37 patients were current smokers (36.3%), 31 patients were diabetics (30.4%), and 32 patients (31.4%) were obese (BMI≥30.0). Average follow-up time was 2.37 (range: 1.04-5.14) years. Risk factors for FRI treatment failure were BMI>30, GA type 3c, and implant retention. Given that FRI treatment in 35.3% (36/102) ended up in failure, clinicians need to take into account the predictive variables analysed in this study, and implement a multidisciplinary team approach to optimise these factors. This study could aid clinicians to redirect efforts to improve high risk patient management, and prompt future studies to trial adjuvant technologies for patients at higher risk of failure


Bone & Joint Open
Vol. 3, Issue 9 | Pages 684 - 691
1 Sep 2022
Rodriguez S Shen TS Lebrun DG Della Valle AG Ast MP Rodriguez JA

Aims. The volume of ambulatory total hip arthroplasty (THA) procedures is increasing due to the emphasis on value-based care. The purpose of the study is to identify the causes for failed same-day discharge (SDD) and perioperative factors leading to failed SDD. Methods. This retrospective cohort study followed pre-selected patients for SDD THA from 1 August 2018 to 31 December 2020. Inclusion criteria were patients undergoing unilateral THA with appropriate social support, age 18 to 75 years, and BMI < 37 kg/m. 2. Patients with opioid dependence, coronary artery disease, and valvular heart disease were excluded. Demographics, comorbidities, and perioperative data were collected from the electronic medical records. Possible risk factors for failed SDD were identified using multivariate logistic regression. Results. In all, 278 patients were identified with a mean age of 57.1 years (SD 8.1) and a mean BMI of 27.3 kg/m. 2. (SD 4.5). A total of 96 patients failed SDD, with the most common reasons being failure to clear physical therapy (26%), dizziness (22%), and postoperative nausea and vomiting (11%). Risk factors associated with failed SDD included smokers (odds ratio (OR) 6.24; p = 0.009), a maximum postoperative pain score > 8 (OR 4.76; p = 0.004), and procedures starting after 11 am (OR 2.28; p = 0.015). A higher postoperative tolerable pain goal (numerical rating scale 4 to 10) was found to be associated with successful SDD (OR 2.7; p = 0.001). Age, BMI, surgical approach, American Society of Anesthesiologists grade, and anaesthesia type were not associated with failed SDD. Conclusion. SDD is a safe and viable option for pre-selected patients interested in rapid recovery THA. The most common causes for failure to launch were failing to clear physical thereapy and patient symptomatology. Risk factors associated with failed SSD highlight the importance of preoperative counselling regarding smoking cessation and postoperative pain to set reasonable expectations. Future interventions should aim to improve patient postoperative mobilization, pain control, and decrease symptomatology. Cite this article: Bone Jt Open 2022;3(9):684–691


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 5 - 5
11 Apr 2023
Mischler D Tenisch L Schader J Dauwe J Gueorguiev B Windolf M Varga P
Full Access

Despite past advances of implant technologies, complication rates of fixations remain high at challenging sites such as the proximal humerus [1]. These may not only be owed to the implant itself but also to dissatisfactory surgical execution of fracture reduction and implant positioning. Therefore, the aim of this study was to quantify the instrumentation accuracy of a highly standardised and guided procedure and its influence on the biomechanical outcome and predicted failure risk. Preoperative planning of osteotomies creating an unstable 3-part fracture and fixation with a locking plate was performed based on CT scans of eight pairs of low-density proximal humerus samples from elderly female donors (85.2±5.4 years). 3D-printed subject-specific guides were used to osteotomise and instrument the samples according to the pre-OP plan. Instrumentation accuracies in terms of screw lengths and orientations were evaluated by comparing post-OP CT scans with the pre-OP plan. The fixation constructs were biomechanically tested until cyclic cut-out failure [2]. Failure risks of the planned and the post-OP configurations were predicted using a validated sample-specific finite element (FE) simulation approach [2] and correlated with the experimental outcomes. Small deviations were found for the instrumented screw trajectories compared to the planned configuration in the proximal-distal (0.3±1.3º) and anterior-posterior directions (-1.7±1.8º), and for screw tip to joint distances (-0.3±1.1 mm). Significantly higher failure risk was predicted for the post-OP compared to the planned configurations (p<0.01) via FE. When incorporating the instrumentation inaccuracies, the biomechanical results could be predicted well with FE (R. 2. =0.70). Despite the high instrumentation accuracy achieved using sophisticated subject-specific 3D-printed guides, even minor deviations from the pre-OP plan significantly increased the FE-predicted risk of failure. This underlines the importance of intraoperative guiding technology [3] in tandem with careful pre-OP planning to assist surgeons to achieve optimal outcomes. Acknowledgements. This study was performed with the assistance of the AO Foundation via the AOTRAUMA Network


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 38 - 38
1 Dec 2021
Yacovelli S Goswami K Shohat N Shahi A Parvizi J
Full Access

Aim. D-dimer is a widely available serum test that detects fibrinolytic activities that occur during infection. Prior studies have explored its utility for diagnosis of chronic periprosthetic joint infections (PJI), but not explored its prognostic value for prediction of subsequent treatment failure. The purpose of this study was to: (1) assess the ability of serum D-dimer and other standard-of-care serum biomarkers to predict failure following reimplantation, and (2) establish a new cutoff value for serum D-dimer for prognostic use prior to reimplantation. Method. This prospective study enrolled 92 patients undergoing reimplantation between April 2015 and March 2019 who had previously undergone total hip/knee resection arthroplasty with placement of an antibiotic spacer for treatment of chronic PJI. Serum D-dimer level, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) levels were measured preoperatively for all patients. Failure following implantation was defined per the Delphi consensus criteria. Optimal cutoffs for D-dimer, ESR, and CRP were calculated based on ROC curves and compared in their association with failure following reimplantation criteria at minimum 1-year follow-up. Results. 15/92(16.3%) patients failed reimplantation surgery at mean follow up of 2.9 years (range 1.0–4.8). Optimal thresholds for D-Dimer, ESR and CRP were determined to be 1300ng/mL, 30mm/hr, and 1mg/L, respectively. The failure rate in patient with positive D-dimer was significantly higher at 32.0% (8/25) compared to those with negative D-dimer 10.6% (7/66); p=0.024. In comparison, 17.8% (8/45) of patients with ESR above threshold failed, compared to 13.89% (5/41) below (p=0.555) and 16.0% (4/25) of patients with CRP above threshold failed, compared to 16.1% (10/62) below (p=1.000). Conclusions. Patients with elevated D-Dimer appear to be at higher risk of failure after reimplantation surgery. This serum marker may be used to generate an additional data point in patients undergoing reimplantation surgery, especially in circumstances when optimal timing of reimplantation cannot be determined based on clinical circumstances


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 72 - 72
4 Apr 2023
Silva-Henao J Pahr DH Reisinger A
Full Access

Primary implant stability is critical for osseointegration and subsequent implant success. Small displacements on the screw/bone interface are necessary for implant success, however, larger displacements can propagate cracks and break anchorage points which causes the screw to fail. Limited information is available on the progressive degradation of stability of an implanted bone screw since most published research is based on monotonic, quasi-static loading [1]. This study aims to address this gap in knowledge. A total of 100 implanted trabecular screws were tested using multi-axial loading test set-up. Screws were loaded in cycles with the applied force increasing 1N in each load cycle. In every load cycle, Peak forces, displacements, and stiffness degradation (calculated in the unloading half of the cycle) where recorded. 10 different loading configurations where tested. The damage vs displacement shows a total displacement at the point of failure between 0.3 and 0.4 mm while an initial stiffness reduction close to 40%. It is also shown that at a displacement of ~0.1 mm, the initial stiffness of every sample had degraded by 20% (or more) meaning that half of the allowable degradation occurred in the first 25-30% of the total displacement. Other studies on screw overloading [1] suggests similar results to our concerning initial stiffness degradation at the end of the loading cycle. Our results also show that the initial stiffness degrades faster with relatively small deformations suggesting that the failure point of an implanted screw might occur before the common failure definition (pull-out force, for example). These results are of great significance since primary implant stability is better explained by the stiffness of the construct than by its failure point


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 34 - 34
1 Oct 2022
Dudareva M Corrigan R Hotchen A Muir R Scarborough C Kumin M Atkins B Scarborough M McNally M Collins G
Full Access

Aim. Smoking is known to impair wound healing and to increase the risk of peri-operative adverse events and is associated with orthopaedic infection and fracture non-union. Understanding the magnitude of the causal effect on orthopaedic infection recurrence may improve pre-operative patient counselling. Methods. Four prospectively-collected datasets including 1173 participants treated in European centres between 2003 and 2021, followed up to 12 months after surgery for clinically diagnosed orthopaedic infections, were included in logistic regression modelling with Inverse Probability of Treatment Weighting for current smoking status [1–3]. Host factors including age, gender and ASA score were included as potential confounding variables, interacting through surgical treatment as a collider variable in a pre-specified structural causal model informed by clinical experience. The definition of infection recurrence was identical and ascertained separately from baseline factors in three contributing cohorts. A subset of 669 participants with positive histology, microbiology or a sinus at the time of surgery, were analysed separately. Results. Participants were 64% male, with a median age of 60 years (range 18–95); 16% of participants experienced treatment failure by 12 months. 1171 of 1173 participants had current smoking status recorded. As expected for the European population, current smoking was less frequent in older participants (Table 1). There was no baseline association between Charlson score or ASA score and smoking status (p=0.9, p=1, Chi squared test). The estimated adjusted odds ratio for treatment failure at 12 months, resulting from current smoking at the time of surgery, was 1.37 for all participants (95% CI 0.75 to 2.50) and 1.53 for participants with recorded confirmatory criteria (95% CI 1.14 to 6.37). Conclusions. Smoking contributes to infection recurrence, particularly in people with unequivocal evidence of osteomyelitis or PJI. People awaiting surgery for orthopaedic infection should be supported to cease smoking, not only to reduce anaesthetic risk, but to improve treatment outcomes. Limitations of this study include unmeasured socioeconomic confounding and social desirability bias resulting in uncertainty in true smoking status, resulting in underestimated effect size


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 31 - 31
10 May 2024
Clatworthy M Rahardja R Young S Love H
Full Access

Background. Anterior cruciate ligament (ACL) reconstruction with concomitant meniscal injury occurs frequently. Meniscal repair is associated with improved long-term outcomes compared to resection but is also associated with a higher reoperation rate. Knowledge of the risk factors for repair failure may be important in optimizing patient outcomes. Purpose. This study aimed to identify the patient and surgical risk factors for meniscal repair failure, defined as a subsequent meniscectomy, following concurrent primary ACL reconstruction. Methods. Data recorded by the New Zealand ACL Registry and the Accident Compensation Corporation, the New Zealand Government's sole funder of ACL reconstructions and any subsequent surgery, was reviewed. Meniscal repairs performed with concurrent primary ACL reconstruction was included. Root repairs were excluded. Univariate and multivariate survival analysis was performed to identify the patient and surgical risk factors for meniscal repair failure. Results. Between 2014 and 2020, a total of 3,024 meniscal repairs were performed during concurrent primary ACL reconstruction (medial repair = 1,814 and lateral repair = 1,210). The overall failure rate was 6.6% (n = 201) at a mean follow-up of 2.9 years, with a failure occurring in 7.8% of medial meniscal repairs (142 out of 1,814) and 4.9% of lateral meniscal repairs (59 out of 1,210). The risk of medial failure was higher in patients with a hamstring tendon autograft (adjusted HR = 2.20, p = 0.001), patients aged 21–30 years (adjusted HR = 1.60, p = 0.037) and in those with cartilage injury in the medial compartment (adjusted HR = 1.75, p = 0.002). The risk of lateral failure was higher in patients aged ≤ 20 years (adjusted HR = 2.79, p = 0.021) and when the procedure was performed by a surgeon with an annual ACL reconstruction case volume of less than 30 (adjusted HR = 1.84, p = 0.026). Conclusion. When performing meniscal repair during a primary ACL reconstruction, the use of a hamstring tendon autograft, younger age and the presence of concomitant cartilage injury in the medial compartment increases the risk of medial meniscal repair failure, whereas younger age and low surgeon volume increases the risk of lateral meniscal repair failure


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 54 - 54
1 May 2021
Debuka E Wilson G Philpott M Thorpe P Narayan B
Full Access

Introduction. IM (Intra Medullary) nail fixation is the standard treatment for diaphyseal femur fractures and also for certain types of proximal and distal femur fractures. Despite the advances in the tribology for the same, cases of failed IM nail fixation continue to be encountered routinely in clinical practice. Common causes are poor alignment or reduction, insufficient fixation and eventual implant fatigue and failure. This study was devised to study such patients presenting to our practice and develop a predictive model for eventual failure. Materials and Methods. 57 patients who presented with failure of IM nail fixation (± infection) between Jan 2011 – Jun 2020 were included in the study and hospital records and imaging reviewed. Those fixed with any other kinds of metalwork were excluded. Classification for failure of IM nails – Type 1: Failure with loss of contact of lag screw threads in the head due to backing out and then rotational instability, Type 2A: Failure of the nail at the nail and lag screw junction, Type 2B: Failure of the screws at the nail lag screw junction, Type 3: Loosening at the distal locking sites with or without infection. X-rays reviewed and causes/site of failure noted. Results. Total patients - 57. Demography - Average age - 58.9 years, 22 Males and 35 females. Eleven patients were noted to have an infection at the fracture site that needed oral or IV antibiotics.16 patients - at least 1 cerclage wire for fracture reduction and fixation + IM Nail. Subtrochanteric fractures (42/57) were the most common to fail. In those fractures with postero-medial comminution, locking of the lag screw in position thus preventing backout can prevent failure. In type 2 failures, preventing varus fixation by early open reduction and temporary fixation with plates and screws can achieve improved results. Those with type 3 failures with periosteal reaction should be considered to be infected until proven otherwise. Conclusions. This classification for failure of IM nails in the femur can be used as a predictive model for failures and allow early recognition and intervention to tackle them


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 4 - 4
1 Apr 2012
Beech Z Trompeter A Singleton AJ Cooper G Hull GJ
Full Access

Hip resurfacing arthroplasty is an established and effective intervention for osteoarthritis of the hip in the young active patient, relying on the principle of femoral bone-stock preservation. A recognised mode of failure is neck thinning leading to radiological evidence of neck collapse and clinical failure. We report on a series of these slow-neck-failure patients and highlight the increased incidence of this phenomenon in post-menopausal female patients. This is a single operator, single implant series; 172 cases were identified from databases at our institution. 76 were female, mean (SD) age 52 (7) years. 96 were male, mean (SD) age 51(12) years. 15 (8.7%) patients required revision. 12 (80%) were female, 9 (75%) of these were due to slow neck failure. In the men one patient developed ALVAL requiring removal of his bilateral hip resurfacings, the other failure mode was early femoral neck failure. Mean time to failure was 6 months in men and 37 months in women. This difference in failure rates is also seen in the NJR figures. This review confirms the relatively high incidence of premature failure in post-menopausal females. NICE guidance in 2003, currently under review, stated that resurfacing is indicated in male patients up to 65 and female patients up to 60. As a result of this study we are currently advising post-menopausal patients that this risk of early failure may make total hip replacement a preferable option to resurfacing arthroplasty


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 80 - 80
2 Jan 2024
Mischler D Windolf M Gueorguiev B Varga P
Full Access

Osteosynthesis aims to maintain fracture reduction until bone healing occurs, which is not achieved in case of mechanical fixation failure. One form of failure is plastic plate bending due to overloading, occurring in up to 17% of midshaft fracture cases and often necessitating reoperation. This study aimed to replicate in-vivo conditions in a cadaveric experiment and to validate a finite element (FE) simulation to predict plastic plate bending. Six cadaveric bones were used to replicate an established ovine tibial osteotomy model with locking plates in-vitro with two implant materials (titanium, steel) and three fracture gap sizes (30, 60, 80 mm). The constructs were tested monotonically until plastic plate deformation under axial compression. Specimen-specific FE models were created from CT images. Implant material properties were determined using uniaxial tensile testing of dog bone shaped samples. The experimental tests were replicated in the simulations. Stiffness, yield, and maximum loads were compared between the experiment and FE models. Implant material properties (Young's modulus and yield stress) for steel and titanium were 184 GPa and 875 MPa, and 105 GPa and 761 MPa, respectively. Yield and maximum loads of constructs ranged between 469–491 N and 652–683 N, and 759–995 N and 1252–1600 N for steel and titanium fixations, respectively. FE models accurately and quantitatively correctly predicted experimental results for stiffness (R2=0.96), yield (R2=0.97), and ultimate load (R2=0.97). FE simulations accurately predicted plastic plate bending in osteosynthesis constructs. Construct behavior was predominantly driven by the implant itself, highlighting the importance of modelling correct material properties of metal. The validated FE models could predict subject-specific load bearing capacity of osteosyntheses in vivo in preclinical or clinical studies. Acknowledgements: This study was supported by the AO Foundation via the AOTRAUMA Network (Grant No.: AR2021_03)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 45 - 45
1 May 2021
Zenios M Oyadiji T Zamani-Farahani A
Full Access

Introduction. A clinical case of catastrophic ring failure in a 13 year old autistic overweight patient during treatment for tibial lengthening and deformity using a Taylor Spatial Frame is reported. Ring failure was noted during the later stages of bone healing and the frame was removed. The clinical outcome was not affected by the catastrophic ring failure. The photograph of the deformed ring is presented below:. Materials and Methods. The patient's notes and X-rays were reviewed and a macroscopic examination of the deformed ring was performed. Mechanical tests of different Taylor Spatial frame constructs were performed in an attempt to simulate the deformity that was clinically observed. Different constructs of TSF of different ring sizes were fixed to polyurethane cylinders simulating bone, were mechanically tested to failure and load/deflection curves were produced. Results. Macroscopically the ring looked otherwise normal. Gradual mechanical compression tests of Taylor Spatial frame constructs showed that ring deformation increased by increasing the ring diameter and by using jointed rather than full joints without a ring. The ring deformation observed clinically was reproduced at the lab by applying high loads on frame constructs composed of large diameter jointed rings not rigidly fixed to bone. Conclusions. Taylor Spatial frame ring failure during treatment is a serious complication that has not been described in the literature. Possible causes are discussed. Clinicians are advised to use the smaller possible diameter rings. Where large diameter rings are required, these rings should preferably be not jointed. Half rings when used should be carefully and securely joined together by the operating surgeon in order to make a complete ring. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of femoral resection (p = 0.001) and extent of quadriceps muscle resection (p = 0.005) for overall prosthetic failure; extent of quadriceps muscle resection (p = 0.002) and fixation of femoral component (p = 0.011) for type 2 failure (aseptic loosening); age (p = 0.009) and percentage of femoral resection (p = 0.019) for type 3 failure (mechanical failure); and type of joint resection (p = 0.037) for type 4 (infection) were independent predictors. A bone stem ratio of > 2.5 reliably predicted aseptic loosening. Conclusion. We identified independent risk factors for overall and cause-specific prosthetic failure after rotating-hinge knee distal femoral arthroplasty using a competing risk Fine-Gray model. A bone stem ratio > 2.5 reliably predicts aseptic loosening. An accurate knowledge of the risks of distal femoral arthroplasty after resection for tumour assists surgical planning and managing patient expectations. Cite this article: Bone Joint J 2021;103-B(8):1405–1413


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded. The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively. We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 40 - 40
10 Feb 2023
Tse C Mandler S Crawford H Field A
Full Access

The purpose of this study is to evaluate risk factors for distal construct failure (DCF) in posterior spinal instrumented fusion (PSIF) in adolescent idiopathic scoliosis (AIS). We observed an increased rate of DCF when the pedicle screw in the lowest instrumented vertebra (LIV) was not parallel to the superior endplate of the LIV, however this has not been well studied in the literature. We hypothesise a more inferiorly angled LIV screw predisposes to failure and aim to find the critical angle that predisposes to failure. A retrospective cohort study was performed on all patients who underwent PSIF for AIS at the Starship Hospital spine unit from 2010 to 2020. On a lateral radiograph, the angle between the superior endplate of the LIV was measured against its pedicle screw trajectory. Data on demographics, Cobb angle, Lenke classification, instrumentation density, rod protrusion from the most inferior screw, implants and reasons for revision were collected. Of 256 patients, 10.9% (28) required at least one revision. The rate of DCF was 4.6% of all cases (12 of 260) and 25.7% of revisions were due to DCF. The mean trajectory angle of DCF patients compared to all others was 13.3° (95%CI 9.2° to 17.4°) vs 7.6° (7° to 8.2°), p=0.0002. The critical angle established is 11°, p=0.0076. Lenke 5 and C curves, lower preoperative Cobb angle, titanium only rod constructs and one surgeon had higher failure rates than their counterparts. 9.6% of rods protruding less than 3mm from its distal screw disengaged. We conclude excessive inferior trajectory of the LIV screw increases the rate of DCF and a screw trajectory greater than 11° predisposes to failure. This is one factor that can be controlled by the surgeon intraoperatively and by avoiding malposition of the LIV screw, a quarter of revisions can potentially be eliminated


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 46 - 46
1 Nov 2021
Luk J Bozynski C Stoker A Stannard J Teixeiro E Cook J
Full Access

Introduction and Objective. Osteochondral allograft (OCA) transplants have been used clinically for more than 40 years as a surgical option for joint restoration, particularly for young and active patients. While immediate graft rejection responses have not been documented, it is believed that the host's immunological responses may directly impact OCA viability, incorporation, integrity, and survival, and therefore, it is of the utmost importance to further optimize OCA transplantation outcomes. The influences of sub-rejection immune responses on OCA transplantation failures have not been fully elucidated therefore aimed to further characterize cellular features of OCA failures using immunohistochemistry (IHC) in our continued hopes for the successful optimization of this valuable surgical procedure. Materials and Methods. With IRB approval, osteochondral tissues that were resected from the knee, hip, and ankle of patients undergoing standard-of-care revision surgeries (N=23) to treat OCA failures and tissues from unused portions of OCAs (N=7) that would otherwise be discarded were recovered. Subjective histologic assessments were performed on hematoxylin and eosin-stained and toluidine blue-stained sections by a pathologist who was blinded to patient demographics, outcomes data, and tissue source. IHC for CD3, CD8, and CD20 were performed to further characterize the and allow for subjective assessment of relevant immune responses. Results. Eleven (48%) of the failed OCAs had aggregates of CD3+, CD8+, and CD20+ lymphocytes around small blood vessels in the bone marrow spaces and adipose/collagenous tissue of the allograft, while the non-implanted healthy control OCA tissues did not show any evidence of inflammation. The remaining failed OCAs (52%) did not show a similar pattern of T- and B-cell infiltrates around blood vessels. Other histologic abnormalities associated with failed OCAs included avascular necrosis, subchondral micro and macro fractures, subchondral collapse, bacterial infection, and/or articular cartilage erosion or delamination. Conclusions. The results from the present study support this possibility in that mixed aggregates of CD3+, CD8+, and CD20+ lymphocytes were observed around small blood vessels in approximately half of the failed OCAs. This potentially cytotoxic immune response may have contributed to the lack of functional survival of the OCA noted in these cases, and warrants further investigation as a possible failure mechanism that may be mitigated using post-transplantation management strategies


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 4 - 4
1 Oct 2021
Pleasant H Robinson P Robinson C Nicholson J
Full Access

Management of highly displaced acromioclavicular joint (ACJ) injuries remain contentious. It is unclear if delayed versus acute reconstruction has an increased risk of fixation failure and complications. The primary aim of this was to compare complications of early versus delayed reconstruction. The secondary aim was to determine modes of failure of ACJ reconstruction requiring revision surgery. A retrospective study was performed of all patients who underwent operative reconstruction of ACJ injuries over a 10-year period (Rockwood III-V). Reconstruction was classed as early (<12 weeks from injury) or delayed (≥12 weeks). Patient demographics, fixation method and post-operative complications were noted, with one-year follow-up a minimum requirement for inclusion. Fixation failure was defined as loss of reduction requiring revision surgery. 104 patients were analysed (n=60 early and n=44 delayed). Mean age was 42.0 (SD 11.2, 17–70 years), 84.6% male and 16/104 were smokers. No difference was observed between fixation failure (p=0.39) or deep infection (p=0.13) with regards to acute versus delayed reconstruction. No patient demographic or timing of surgery was predictive of fixation failure on regression modelling. Overall, eleven patients underwent revision surgery for loss of reduction and implant failure (n=5 suture fatigue, n=2 endo-button escape, n=2 coracoid stress fracture and n=2 deep infection). This study suggests that delayed ACJ reconstruction does not have a higher incidence of fixation failure or major complications compared to acute reconstruction. For those patients with ongoing pain and instability following a trial of non-operative treatment, delayed reconstruction would appear to be a safe treatment approach


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 77 - 77
24 Nov 2023
Oehen L Morgenstern M Wetzel K Goldenberger D Kühl R Clauss M Sendi P
Full Access

Aim. One of the surgical therapeutic options for periprosthetic joint infection (PJI) includes debridement, antibiotics, and implant retention (DAIR). Prognostically favorable criteria for DAIR include short duration of symptoms, stable implant, pathogen susceptible to a ‘biofilm-active’ antimicrobial agent, and intact soft-tissue conditions. Despite this, there is a proportion of failures after DAIR, possibly because the duration of infection is underestimated. With the hypothesis that the duration of infection correlates with the bacterial load, and hence, the bacterial load is associated with failure after DAIR, we aimed to investigate the association of bacterial load in the sonication fluid of mobile parts and clinical outcome after DAIR. Method. From our PJI cohort (2010–2021), patients with DAIR (both palliative and curative approaches) were reviewed retrospectively. Patients with hip, knee or shoulder arthroplasties fulfilling infection definition, available sonication results, and ≥2 years follow-up were included. Sonication results were categorized in ≤ or >1000 cfu/mL. Univariate analysis was performed to identify predictors for DAIR failure. Results. Out of 209 PJIs, we identified 96 patients (100 PJIs, 47.8%) with DAIR. In 67 (69.8%) patients with 71 PJIs, there was a follow-up of ≥2 years. The mean age was 72.7 (SD 12.99) years, 50% were male. The infection affected 36 hips (50.7%), 32 knees (45.1%) and 3 shoulders (4.2%). At follow-up, there were 29 (40.8%) cured and 42 (59.2%) failed cases. When comparing failed and cured cases, we found no difference in comorbidities and previously defined risk factors for PJI, ASA score, Charlson score, anatomic location, no. of previous surgeries, pathogenesis of infection or laboratory values. The proportion of patients with high bacterial load on mobile parts (i.e. >1000 cfu/mL) was significantly higher in the failed DAIR group than it was in the cured group (61.9% vs 20.7%, p<0.001). Conclusions. In this study, a high bacterial load in sonication fluid of mobile parts was associated with failure after DAIR in patients with PJI. Sonication may help to differentiate acute hematogenous seeding to the implant and late reactivation of a previously silent implant-associated infection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 3 - 3
1 Aug 2022
Tailor P Sewell M Jones M Spilsbury J Marks D Gardner A Mehta J
Full Access

The lordosis distribution index (LDI) describes distribution of lumbar lordosis, measured as the % of lower lumbar lordosis (L4-S1) compared to global lordosis (L1-S1) with normal value 50–50%. Maldistributed LDI is associated with higher revision in short lumbar fusions, 4 vertebrae1. We hypothesise maldistributed LDI is also associated with mechanical failure in longer fusions. Retrospective review of 29 consecutive ASD patients, aged 55+, undergoing long lumbar fusion, 4 levels, with >3-years follow-up. LDI, pelvic incidence (PI) and sagittal vertical axis (SVA) were measured on pre- and post-op whole spine standing X-rays (Fig A and B). Patients were categorized according to their pelvic incidence (PI) and postoperative LDI: Normal (LDI 50 80), Hypolordotic (LDI < 50), or Hyperlordotic (LDI > 80) and assessed for failure rate compared to normal LDI and PI <60. Mean follow-up 4.5 years. 19 patients had mechanical failures including junctional failure and metalware fracture. PI >60o was associated with higher mechanical failure rates (Chi^2 p<0.05). Hypolordotic LDI was associated with 82% mechanical failure (Chi^2 p<0.001), Hyperlordotic 88% mechanical failure (Chi^2 p<0.001) and Normal 8% mechanical failure (Table 1). Maldistributed LDI, whether Hyperlordotic or Hypolordotic, correlated with 10× greater mechanical failure rate compared to Normal LDI in long fusions. LDI is a useful measurement that should be considered, especially in high PI patients


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were rod fractures preceded by a mean CS of 6.1 mm (2 to 18) and LA kyphotic enhancement of 10.8° (-1 to 36). IF-free survival rates were 75.8% at five years and 56.9% at ten years. The interval from TES to IF peaked at two to three years postoperatively and continued to occur over a period of time thereafter; the early IF-developing group had greater CS at one month postoperatively (CS1M) and more lumbar TES. CS1M ≥ 3 mm and sole use of frozen autografts were identified as independent risk factors for IF. Conclusion. IF is a common complication following TES. We have demonstrated that robust spinal reconstruction preventing CS, and high-quality bone grafting are necessary for successful reconstruction. Cite this article: Bone Joint J 2023;105-B(2):172–179


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 38 - 38
1 Nov 2021
Argenson J Jaubert M LeBaron M Ollivier M Flecher X
Full Access

Two-stage exchange revision total hip arthroplasty performed in case of infection has been considered during many years the gold standard for treatment of chronic infection. Nevertheless, during the last decade, concerns have risen regarding its safety and its efficiency. The purpose of our study was to, first investigate the spacer complications, then to analyze their risks factors. We retrospectively included 125 patients with chronic hip periprosthetic joint infection who underwent a two stage exchange revision arthroplasty performed between January 2013 and December 2019. All spacer complications were systematically collected and risk factors were analyzed. Statistical evaluation were performed using the Student and Mann-Whitney tests. Our study confirms the hypothesis of a high-risk strategy with 42% of patients who had a mechanical spacer failure and a 20% recurrence of infection during the average two years period of follow-up. We found a high rate of spacer migration (23%) and a low rate of spacer fracture (8%) compared to literature. The most important finding was that the majority of spacer complications and failures were found in a population with high medical comorbidities as highlighted by the ASA, Charlson and Lee score associations, as well as with the cardiac, pulmonary, kidney or hepatic chronic conditions. This study showed that a two-stage hip exchange revision is a high-risk procedure regarding complications and mechanical failures of PMMA spacers. In patients with high medical comorbidities, other strategies may be considered and interdisciplinary cooperation with other facilities are needed to identify and control each risk factor


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 617 - 617
1 Oct 2010
Klobucar H Bosiljkov T Cicak N Trkulja B Trsek D
Full Access

Purpose: The study in vitro compares primary fixation strength of two arthroscopic flip knots; clinical knot security and ultimate load to failure. SMC knot is well known and frequently used arthroscopic knot. SAK (Secure Arthroscopic Knot) is fully instrumental knot, easy to master, with short learning curve. Published 10 years ago, during that period it is predominantly used by senior author in arthroscopic shoulder procedures. Materials and Methods: Curved metal rods are put in grips of the Universal Testing Machine and positioned centraly in vertical orientation 5 mm apart. The curvature of each rod was wrapped with 2 mm deerskin soaked in saline. Arthorscopic canulla was positioned in holder on the same position during testing procedure for all knots. Knots – 8 SAK and 8 SMC – were constructed outside the canulla, slided and positioned with arthroscopic knot pusher on the concave side of the caudal rod. Four additional loops (left-right alternatively) were put on the knot. Orthocord was used in all procedures, and all knots were performed by the same surgeon. The construct was preloaded with 7 N and distracted 0, 1mm/s. Ultimate tensile load (UF) and clinical load to failure (CF) were determined. Clinical load to failure is defined as force that distract knot for 3 mm. Data distribution was analysed and parametric statistics was performed. Results: Clinical failure for SAK is 249±29 N, and for SMC 191±40 N, and this difference is significant on the level of 5 %. Ultimate failure of SAK is 292±34 N and for SMC 276±39 N, and this difference is not significant. SAK failured with breakage in 7 out of 8 measurments, and SMC failured equaly by slipage and breakage. Discussion/Conclusion: The study imitated in vivo condition, slipage of knots during test was eliminated using deerskin which simulated human tissue. Both knots are equally strong regarding ultimate load to failure in hands of the experienced shoulder arthroscopist. Secure arthroscopic knot (SAK) presented greater load to clinical failure comparing with SMC knot. Autors can recomend SAK as an easy and safe arthroscopic flip knot


Aims. Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. Methods. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes. Results. The study cohort consisted of 84 patients, of whom 59.5% (n = 50) had successful eradication of their infection at a mean follow-up of 4.7 years. For the 34 patients who had recurrence of infection, 58.8% (n = 20) had a change in isolated organism, compared to 18% (n = 9) in the infection eradication group (p < 0.001). When adjusting for confound, there was no association when the growth on the second stage was the same as the first (odd ratio (OR) 2.50, 95% confidence interval (CI) 0.49 to 12.50; p = 0.269); however, when a different organism was identified at the second stage, this was independently associated with failure of treatment (OR 8.40, 95% CI 2.91 to 24.39; p < 0.001). There were no other significant differences between the two cohorts with regard to patient demographics or type of organisms isolated. Conclusion. Change in the identified microorganism between first- and second-stage revision for PJI was associated with failure of management. Identification of this change in the microorganism prior to commencement of the second stage may help target antibiotic management and could improve the success of surgery in these patients. Cite this article: Bone Jt Open 2023;4(9):720–727


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 69 - 69
1 Dec 2022
Clarke M Beaudry E Besada N Oguaju B Nathanail S Westover L Sommerfeldt M
Full Access

Meniscal root tears can result from traumatic injury to the knee or gradual degeneration. When the root is injured, the meniscus becomes de-functioned, resulting in abnormal distribution of hoop stresses, extrusion of the meniscus, and altered knee kinematics. If left untreated, this can cause articular cartilage damage and rapid progression of osteoarthritis. Multiple repair strategies have been described; however, no best fixation practice has been established. To our knowledge, no study has compared suture button, interference screw, and HEALICOIL KNOTLESS fixation techniques for meniscal root repairs. The goal of this study is to understand the biomechanical properties of these fixation techniques and distinguish any advantages of certain techniques over others. Knowledge of fixation robustness will aid in surgical decision making, potentially reducing failure rates, and improving clinical outcomes. 19 fresh porcine tibias with intact medial menisci were randomly assigned to four groups: 1) native posterior medial meniscus root (PMMR) (n = 7), 2) suture button (n = 4), 3) interference screw (n = 4), or 4) HEALICOIL KNOTLESS (n = 4). In 12 specimens, the PMMR was severed and then refixed by the specified group technique. The remaining seven specimens were left intact. All specimens underwent cyclic loading followed by load-to-failure testing. Elongation rate; displacement after 100, 500, and 1000 cycles; stiffness; and maximum load were recorded. Repaired specimens had greater elongation rates and displacements after 100, 500, and 1000 cycles than native PMMR specimens (p 0.05). The native PMMR showed greater maximum load than all repair techniques (p 0.05). In interference screw and HEALICOIL KNOTLESS specimens, failure occurred as the suture was displaced from the fixation and tension was gradually lost. In suture button specimens, the suture was either displaced or completely separated from the button. In some cases, tear formation and partial failure also occurred at the meniscus luggage tag knot. Native PMMR specimens failed through meniscus or meniscus root tearing. All fixation techniques showed similar biomechanical properties and performed inferiorly to the native PMMR. Evidence against significant differences between fixation techniques suggests that the HEALICOIL KNOTLESS technique may present an additional option for fixation in meniscal root repairs. While preliminary in vitro evidence suggests similarities between fixation techniques, further research is required to determine if clinical outcomes differ


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 82 - 82
1 Jul 2022
Walker L Clement N Deehan D
Full Access

Abstract. Introduction. The prevalence of recurrent infection following two-stage exchange arthroplasty following failure of a total knee arthroplasty (TKA) has been reported to be 10% to 25%. There is limited literature available on repeat two stage revisions for TKA infection with only small cohorts and variable success rates. Methodology. A retrospective cohort study investigating the outcome of two stage revision arthroplasty for treatment of TKA infection was conducted with the aim of identifying factors linked to recurrence of infection. A consecutive cohort of all microbiology intra-operative periprosthetic knee samples from a single revision arthroplasty centre between January 2010 and December 2016 was identified. The final cohort consisted of 658 samples taken during 64 patients undergoing two stage revision knee surgery for infection. Patient demographics, medical and orthopaedic history data including post-operative outcomes and subsequent treatment was obtained from the electronic records system and medical notes. Results. 65.6% of the cohort (N=42) had successful eradication of their infection. For the twenty-two patients that had failure of their two stage revision, twenty patients had samples available from further surgical intervention. Sixteen patients (80%) had different organisms isolated when they had repeat surgical samples taken when compared to their first stage samples. Overall, for subsequent treatments there was a success rate of 75% if the same organism was identified and 62.5% if there were new isolated organisms. Conclusion. These findings may have implications for the treatment strategies chosen for re-infection after two stage TKA revisions if new causative organisms are isolated


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 101 - 104
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):101–4


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 135 - 144
1 Jul 2021
Kuyl E Shu F Sosa BR Lopez JD Qin D Pannellini T Ivashkiv LB Greenblatt MB Bostrom MPG Yang X

Aims. Aseptic loosening is a leading cause of uncemented arthroplasty failure, often accompanied by fibrotic tissue at the bone-implant interface. A biological target, neutrophil extracellular traps (NETs), was investigated as a crucial connection between the innate immune system’s response to injury, fibrotic tissue development, and proper bone healing. Prevalence of NETs in peri-implant fibrotic tissue from aseptic loosening patients was assessed. A murine model of osseointegration failure was used to test the hypothesis that inhibition (through Pad4-/- mice that display defects in peptidyl arginine deiminase 4 (PAD4), an essential protein required for NETs) or resolution (via DNase 1 treatment, an enzyme that degrades the cytotoxic DNA matrix) of NETs can prevent osseointegration failure and formation of peri-implant fibrotic tissue. Methods. Patient peri-implant fibrotic tissue was analyzed for NETs biomarkers. To enhance osseointegration in loose implant conditions, an innate immune system pathway (NETs) was either inhibited (Pad4-/- mice) or resolved with a pharmacological agent (DNase 1) in a murine model of osseointegration failure. Results. NETs biomarkers were identified in peri-implant fibrotic tissue collected from aseptic loosening patients and at the bone-implant interface in a murine model of osseointegration failure. Inhibition (Pad4-/-) or resolution (DNase 1) of NETs improved osseointegration and reduced fibrotic tissue despite loose implant conditions in mice. Conclusion. This study identifies a biological target (NETs) for potential noninvasive treatments of aseptic loosening by discovering a novel connection between the innate immune system and post-injury bone remodelling caused by implant loosening. By inhibiting or resolving NETs in an osseointegration failure murine model, fibrotic tissue encapsulation around an implant is reduced and osseointegration is enhanced, despite loose implant conditions. Cite this article: Bone Joint J 2021;103-B(7 Supple B):135–144


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


Bone & Joint Research
Vol. 5, Issue 2 | Pages 52 - 60
1 Feb 2016
Revell PA Matharu GS Mittal S Pynsent PB Buckley CD Revell MP

Objectives. T-cells are considered to play an important role in the inflammatory response causing arthroplasty failure. The study objectives were to investigate the composition and distribution of CD4+ T-cell phenotypes in the peripheral blood (PB) and synovial fluid (SF) of patients undergoing revision surgery for failed metal-on-metal (MoM) and metal-on-polyethylene (MoP) hip arthroplasties, and in patients awaiting total hip arthroplasty. Methods. In this prospective case-control study, PB and SF were obtained from 22 patients (23 hips) undergoing revision of MoM (n = 14) and MoP (n = 9) hip arthroplasties, with eight controls provided from primary hip osteoarthritis cases awaiting arthroplasty. Lymphocyte subtypes in samples were analysed using flow cytometry. Results. The percentages of CD4+ T-cell subtypes in PB were not different between groups. The CD4+ T-cells in the SF of MoM hips showed a completely different distribution of phenotypes compared with that found in the PB in the same patients, including significantly decreased CD4+ T-central memory cells (p < 0.05) and increased T-effector memory cells (p < 0.0001) in the SF. Inducible co-stimulator (ICOS) was the only co-stimulatory molecule with different expression on CD4+ CD28+ cells between groups. In PB, ICOS expression was increased in MoM (p < 0.001) and MoP (p < 0.05) cases compared with the controls. In SF, ICOS expression was increased in MoM hips compared with MoP hips (p < 0.05). Conclusions. Increased expression of ICOS on CD4+ T-cells in PB and SF of patients with failed arthroplasties suggests that these cells are activated and involved in generating immune responses. Variations in ICOS expression between MoM and MoP hips may indicate different modes of arthroplasty failure. Cite this article: Professor P. A. Revell. Increased expression of inducible co-stimulator on CD4+ T-cells in the peripheral blood and synovial fluid of patients with failed hip arthroplasties. Bone Joint Res 2016;5:52–60. doi: 10.1302/2046-3758.52.2000574


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims. We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed. . Methods. All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation. Results. There were 113 recorded cases with fracture at the modular junction, resulting in a calculated fracture rate of 0.30% (113/37,600). The fracture rate of the implant without signs of improper use was 0.11% (41/37,600). In 79% (89/113) of cases with a failed implant, either a lateralized (high offset) neck segment, an extralong head, or the combination of both were used. Logistic regression analysis revealed male sex, high body mass index (BMI), straight component design, and small neck segments were significant risk factors for failure. Investigation of the implants (76/113) showed at least one sign of improper use in 72 cases. Conclusion. Implant failure at the modular junction is associated with patient- and implant-specific risk factors as well as technical errors during implantation. Whenever possible, the use of short and lateralized neck segments should be avoided with this revision system. Implantation instructions and contraindications need to be adhered to and respected. Cite this article: Bone Joint J 2020;102-B(5):573–579


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction. We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms. Methods. We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction. Results. The 70 patients (54 male/ 16 female) had an average age of 69 (range 48–84 years). Mean follow up was 76 months (range 60–04), 10 patients died during the follow up. Implant survivorship was 81.4% at most recent follow up. The commonest radiographic finding was periprosthetic cysts (n=28, 40%), size range (7–40mm), location of cysts: isolated talus (n=14), isolated tibia (n=6), mixed (n=8). 10 failed TARs were revised to Inbone TAR at a mean of 48 months (range 9–69). 3 Failed TARs were revised to arthrodesis (2 tibiotalar fusions, 1 hindfoot nail). 11 patients required reoperation with implant retention: 8 periprosthetic cyst debridement and grafting at a mean of 61 months (range 27–91), 1 lateral gutter debridement and 1 periprosthetic fracture ORIF. PROMS data was available for all patients. Overall patients showed marked improvement in functional outcome scores between pre-operative and final follow up questionnaires. Mean pre-op AOS: 62, MOX-FQ: 68 and pain VAS: 67.5 with mean final follow up scores of: AOS: 35, MOX-FQ: 36 and pain VAS: 30. Conclusion. Our experience demonstrates improved PROMS following ankle arthroplasty for patients with a mean follow up of 6.4 years. Implant survivorship is similar to other TAR studies. We have identified a high incidence of periprosthetic cysts and would recommend ongoing surveillance of these patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 70 - 70
1 Dec 2021
Shao H Li R Deng W Yu B Zhou Y Chen J
Full Access

Aim. The purpose of this study is to report the overall infection control rate and prognostic factors associated with acute, hematogenous and chronic PJIs treated with DAIR. Methods. All DAIR procedures performed at 2 institutions from 2009 to 2018 (n=104) were reviewed and numerous data were recorded, including demographics, preoperative laboratory tests, Charleston Comorbidity Index, surgical information and organism culture results. Treatment success was defined according to the criteria reported by Diaz-Ledezma. A multivariable analysis was utilized to identify prognostic factors associated with treatment and a Kaplan-Meier survival analysis was used to depict infection control rate as a function of time. Results. The overall treatment success rate in the current cohort of patients was 67.3% at a median 38.6 (23.5–90.7) months follow-up. Patients with a duration of infectious symptoms greater than 10 days were more likely to fail (P=0.035, odds ratio 8.492, 95% confidence interval 1.159–62.212). There was no difference among acute, hematogenous and chronic infections in terms of failure rate even when time was considered (p=0.161). Conclusion. With careful patient selection, DAIR is a reasonable treatment option for PJI and its use in the setting of chronic infection does not appear to be a contraindication. Performing the DAIR procedure within 10 days of the presentation of symptoms had higher rates of treatment success


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 916 - 922
1 May 2021
Qiao J Xu C Chai W Hao L Zhou Y Fu J Chen J

Aims. It can be extremely challenging to determine whether to perform reimplantation in patients who have contradictory serum inflammatory markers and frozen section results. We investigated whether patients with a positive frozen section at reimplantation were at a higher risk of reinfection despite normal ESR and CRP. Methods. We retrospectively reviewed 163 consecutive patients with periprosthetic joint infections (PJIs) who had normal ESR and CRP results pre-reimplantation in our hospital from 2014 to 2018. Of these patients, 26 had positive frozen sections at reimplantation. The minimum follow-up time was two years unless reinfection occurred within this period. Univariable and multivariable logistic regression analyses were performed to identify the association between positive frozen sections and treatment failure. Results. Treatment failure occurred in eight (30.77%) of the 26 PJI patients with positive frozen sections at reimplantation, compared with 13 (9.49%) of 137 patients with negative results. In the multivariate analysis, positive frozen section increased the risk of failure (odds ratio 4.70; 95% confidence interval (CI) 1.64 to 13.45). The mean number of months to reinfection was lower in the positive frozen section group than in the control group (p = 0.041). While there were nine (34.62%) patients with positive frozen section and 25 (18.25%) patients with negative frozen section who had prolonged antibiotic use (p = 0.042), the mean duration of antibiotic use was comparable in two groups. Synovial white blood cell count (p = 0.137) and polymorphonuclear leucocyte percentage (p = 0.454) were not associated with treatment failure in logistic regression model. Conclusion. Positive frozen section at reimplantation was independently associated with subsequent failure and earlier reinfection, despite normal ESR and CRP levels pre-reimplantation. Surgeons should be aware of the risk of treatment failure in patients with positive frozen sections and carefully consider benefits of reimplantation. Cite this article: Bone Joint J 2021;103-B(5):916–922