header advert
Results 1 - 50 of 126
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 383 - 383
1 Jul 2010
Dakhil-Jerew F Shepperd J
Full Access

Introduction: In this study we have studied the range of motion within Dynesys treated discs and levels adjacent to flexible stabilisation. Dynesys was designed to offer physiological motion at the lumbar spine. An advantage which is superior to abolishing movements through spinal fusion. Methods: A cohort of 75 post-Dynesys patients had weight-bearing lateral lumbar spine x rays in flexion/extension positions. Evaluation was done through PACS™ digital software. Flexibility at individual disc level was measured as the differences between flexion/extension angles accurate to within 1°. Motion was evaluated at the index and immediate adjacent levels. Results: Patients with single level Dynesys had an average ROM of (3+/−4.7) at L5-S1 and (5.1+/−2.9) at the immediate adjacent level. Two levels Dynesys was associated with a ROM of 5+/−3.6 at L5-S1 & L4–5 and 3.5+/−1.8 at their immediate neighbour disc. Across three levels, Dynesys favoured a ROM of 5.3+/−2.5 at the operated sites and 1.6+/− 2 at the adjacent level. Discussion & Conclusion: This study is the first radiological research to confirm the flexibility of Dynesys. Controlled motion at the dynesys treated disc levels share to distribute global spinal movements. This will advantage the next disc segments and protects them from risk of developing “accelerated adjacent segment disease”


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 210 - 210
1 Jun 2012
Sharma RK
Full Access

There is still want of evidence in the current literature of any significant improvement in clinical outcome when comparing computer-assisted total knee arthroplasty (CA-TKA) with conventional implantation. Analysis of alignment and of component orientation have shown both significant and non-significant differences between the two methods. Not much work has been reported on clinical evidence of stability of the joint. We compared computer-assisted and conventional surgery for TKA at 5.4 years follow-up for patients with varus osteoarthritic knees with deformity of more than 15∗. Our goal was to assess clinical outcome, stability and restoration of normal limb alignment. We used CT and Cine video X ray techniques to analysize our results in Computer navigated and conventional TKRs. A three dimentional CT scan of the whole extremity was performed and evaluation was done in three planes; saggital, coronal and transverse views. CT scan was done between 10 to 14 days postoperative. Mean deviations in the mechanical axis, femoral and tibial plateau angles, and in transverse view, the trans-epicondylar axis vs posterior condylar axis were measured. The prospective randomized study comprised of 98 patients with surgery done on knees, one side navigated and other side conventional. Mean deviation in the mechanical axis was 2.2∗ in conventional knees and 1.8∗ in navigated knees. In 5 % of cases retinacular release was needed and CT analysis showed TEA in deviation of more than 2 ∗ in these cases. We analysed intraoperative data (surgical time and intraoperative complications), postoperative complications, lower limb alignment, radiographic complication on X-ray imaging, and clinical outcome throughknee and function score, range of motion and joint stability. Our results showed that CAS had greater consistency and accuracy in implant placement and stability of joint in full extension and 90∗ flexion. In the coronal view, 93.3% in the CAS group had better outcomes compared with EM (73.4%). In the sagittal axis, 90.0% CAS also had better outcomes compared with EM (63.3%). Computer-navigated total knee arthroplasty helps increase accuracy and reduce “outliers” for implant placement


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 178 - 178
1 Mar 2009
Obert L Lepage D Rochet S Klingelschmitt S Blagonoskonov O Tropet Y Garbuio P
Full Access

Introduction: Occult fractures of carpal bones are underestimed. To be treated succesfully fractures of the scaphoid must be identified at an early stage. A delay in detection may result in non union. We validated with 3 prospective studies a new tool using scintigraphy : The quantitative Xray bone scan (QRS). Material and Methods: A previous preliminary prospective study with 60 patients was performed and published to valid the QRS as a step in diagnosis of wrist occult bones fractures equal to RMI. This exam is a bone scan with 2 improvments. 1) A quantification of the fixation spot : If the spot is two times more important on the injuried wrist (than controlateral side) the fracture is sure. 2) If you combine plain Xrays of the the wrist with scintigraphy the fracture is automatically located. This previous report pointed that repeat set of scaphoid views, dynamic and static, Ct scan, proved unsuitable for screening occult fractures of the wrist. Result: Between november 97 and march 04, 667 patients were enrolled in a prospective continue study. 40% (260/667) of patients with an injury of the wrist with normal X ray sustained an occult fracture. QRS was performed at an average of 17,7 days after the injury and after clinical exam and repeat set of scaphoid view. Scaphoid fractures were most frequent. Fixation was most important if scintigraphy was performed between 11 and 20 days after the injury. Fixation did not depend on age, sex, volume of the bone, and delay (after 15 days). Discussion: As Dikson, Dias, Thompson, and Kuckla, repeat set of scaphoid view are unable to improve significativally the number of occult fractures of the wrist. RMI as reported by Kuckla can reduce the need for further imaging procedure. RMI and scintigraphy are both the best exam to diagnose surely an occult fracture of the wrist. But QRS does not over diagnose, as RMI, bones fracture’s. Conclusion: “Plaster cast and wait” is not the treatment for occult carpal bones fracture’s. The quantitative Xray bone scan is able to diagnose such fractures with short delay


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 47 - 47
1 Mar 2013
Blake C Van Der Merwe J Human B
Full Access

Background

Using digital X-rays to plan a hip replacement can cause problems with sizing and templating the prosthesis. Using an AP view of both hips is desirable as this allows the use of the sometimes unaffected contralateral hip for templating.

Method

We devised a method of using a 20mm ball bearing as a marker positioned at the same depth as the greater trochanter, but between the patient's legs. Placing the marker between the patient's legs avoids the problem of the marker disappearing off the side of the X-ray, as is seen when placing the marker at the side of the obese patient. The marker is then used to calibrate the size of the digital X-ray. We used a hundred consecutive post-operative X-rays, comparing the size of the head of the femoral prosthesis used at surgery with the size measured pre-operatively using the marker.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 304 - 304
1 Mar 2004
Venesmaa P Miettinen H Jurvelin J Suomalainen O Kršger H
Full Access

Aim of the study: The aim of the study was to register and þnd out the longterm femoral bone response after insertion of femoral stem with or with-out cement. Materials and methods: Seventeen patients (7 men, 10 women) underwent cemented and 22 patients (14 men, 8 women) uncemented total hip arthroplasty (THA). The mean age in the cemented group was 69 (58–74) years and in the uncemented group 58 (46–68) years. Femoral bone mineral density (BMD) was measured using Lunar DPX or Lunar DPX-IQ densitometry according to zones by Gruen (ROI 1–7). BMD measurements were made preoperatively, and postoperatively over four to 14 days, and at 3, 6, 12, 24, and 36 months after THA. Postoperative BMD changes were calculated using the immediate postoperative BMD value as a reference, the change being expressed as a percent. Results: Peri-prosthetic BMD decreased signiþcantly almost in all ROIs during the þrst three months after both cemented (5–18%) and uncemented (3–14%) THA (p-values < 0.05 to p< 0.001). At the end of the þrst year the most remarkable decrease in BMD was found in the calcar (zone 7) in both groups (cemented 25%; uncemented 23%). Low preoperative bone loss predicted higher periprosthetic bone loss in both groups. From one to three year only small changes in periprosthetic BMD were detected after THA. Conclusions: The present study suggests that postoperative bone loss is equal after uncemented and cemented THA. The bone loss is most pronounced during the þrst six months after THA and mainly associated in proximal femoral bone. After the phase of acute bone loss, further loss is minimal after uncomplicated THA, reßecting merely the normal aging of bone. Patients with poor bone quality at baseline are at higher risk to lose bone around the prosthesis after THA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIII | Pages 9 - 9
1 Apr 2012
Pande R Dhir J Pyrovolou N Ahuja S
Full Access

Purpose

To evaluate Radiological changes in the lumbosacral spine after insertion of Wallis Ligament for Foraminal Stenosis.

Methods and Results

Thirty two Levels in Twenty Six patients were followed up with standardised radiographs after insertion of Wallis Ligaments for Foraminal Stenosis. Wallis ligaments as a top-off or those with prolapsed discs were not included. The Radiological parameters compared were Anterior and Posterior Disc height, Foraminal height and width, The inter-vertebral angle (IVA), Lumbar lordosis and Scoliosis if any. The presence of slips and their progression post-op was noted, as was bony lysis if any.

There were ten males with thirteen levels and sixteen females with nineteen levels in the study. Eighteen levels (56.25%) were L4/L5, ten (31.25%) were L5/S1 and 4 (12.5%)were L3/L4. The average age in the series was 59.6 years (Range 37 – 89 yrs). Average follow up was 9.5 months (Range 2 to 36). The Average increase in Anterior disc height was 1.89 mm (+/−1.39), the posterior disc height increased by an average 1.09 mm (+/−1.14). Foraminal height increased by an average 3.85 mm (+/− 2.72), while foraminal width increased by 2.14 mm (+/− 1.38). The IVA increased in 16 and reduced in 15 patients, with no change in 1. Lumbar Lordosis increased in 23 patients, with an average value of 2.3°. No patient exhibited progression in scoliosis and no lysis could be identified. There were three Grade I slips pre-op; none progressed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 106 - 106
1 Apr 2012
Pande R Dhir J Pyrovolou N Ahuja S
Full Access

To evaluate Radiological changes in the lumbosacral spine after insertion of Wallis Ligament for Foraminal Stenosis.

Thirty two Levels in Twenty Six patients were followed up with standardised radiographs after insertion of Wallis Ligaments for Foraminal Stenosis. Wallis ligaments as a top-off or those with prolapsed discs were not included. The Radiological parameters compared were Anterior and Posterior Disc height, Foraminal height and width, The inter-vertebral angle (IVA), Lumbar lordosis and Scoliosis if any. The presence of slips and their progression post-op was noted, as was bony lysis if any.

There were ten males with thirteen levels and sixteen females with nineteen levels in the study. Eighteen levels (56.25%) were L4/L5, ten (31.25%) were L5/S1 and 4 (12.5%)were L3/L4. The average age in the series was 59.6 years (Range 37 – 89 yrs). Average follow up was 9.5 months (Range 2 to 36). The Average increase in Anterior disc height was 1.89 mm (+/−1.39), the posterior disc height increased by an average 1.09 mm (+/−1.14). Foraminal height increased by an average 3.85 mm (+/− 2.72), while foraminal width increased by 2.14 mm (+/− 1.38). The IVA increased in 16 and reduced in 15 patients, with no change in 1. Lumbar Lordosis increased in 23 patients, with an average value of 2.3°. No patient exhibited progression in scoliosis and no lysis could be identified. There were three Grade I slips pre-op; none progressed.

Foraminal dimensions and Disc height were consistently improved after Wallis insertion. Changes in IVA and Lumbar lordosis were however variable. A longer follow up is suggested to look for sustained improvement and the presence of lysis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 51 - 51
1 Dec 2020
Khan MM Pincher B Pacheco R
Full Access

Aims and objectives

Our aim was to evaluate the indications for patients undergoing magnetic resonance imaging (MRI) of the knee prior to referral to an orthopaedic specialist, and ascertain whether these scans altered initial management.

Materials and Method

We retrospectively reviewed all referrals received by a single specialist knee surgeon over a 1-year period. Patient demographics, relevant history, examination findings and past surgical procedures were documented. Patients having undergone MRI prior to referral were identified and indications for the scans recorded. These were reviewed against The NHS guidelines for Primary Care Physicians to identify if the imaging performed was appropriate in each case.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 91 - 91
1 Mar 2021
Martin R Critchley R Anjum S
Full Access

Neck of femur fractures are a common presentation and certain patients can be managed with a total hip replacement. To receive a total hip replacement the pelvic X-rays should be templated as per AO guidelines and a common way this is performed is by including a calibration marker on the X-ray. The aim of this study is to assess and improve upon the use of the calibration marker. Details of patients admitted with a neck of femur fracture from January 1st 2018 until December 31st 2018 were gathered and used to review each initial X-ray and determine if a calibration marker was included. 376 patients were admitted with a neck of femur fracture over the one year period. 36% of patients did not have a calibration marker on their initial pelvic X-ray and 11% did not have a chest X ray. 215 patients had an intracapsular fracture and 39 went on to have a total hip replacement. 12 patients were lacking a calibration marker on their original X ray and required a repeat X ray. After a poster was placed in the radiographer booth acting as a visual aid, the use of a calibration marker improved from 62% to 70%. Calibration markers are useful tools which can aid the pre-operative planning for hip replacement surgeries shortening operative time, increase precision and reduce prosthetic loosening, lowers the risk of peri-prosthetic fractures, reduce leg length discrepancy and ensure the required implants are available. If a marker is not included on the initial X-rays, and a patient has a neck of femur fracture which requires a joint replacement, they may have to have additional X-rays performed as was the case for 12 patients in this study. This process leads to possible delays in surgery, additional radiation and increased healthcare costs


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 311 - 311
1 Mar 2004
Garneti N Davies A Smith E Learmonth I
Full Access

Aims: Irradiated allograft bone may help to reduce the risk of transmission of infectious agents from donor to recipient. The purpose of this study was to establish the results of impaction bone grafting of acetabular defects with froze, irradiated allograft bone. Methods: All patients treated by a single surgeon with impaction bone grafting of acetabular defects at revision total hip replacement were reviewed retrospectively. All operations were performed during the period 1994–2000. The mean follow-up was 50 months (range 30–96 months). Case notes and X rays were reviewed and analysed. The Paprosky grade of acetabular defects was determined from the pre-operative X rays and the surgeonñs operation note. Post-operative X rays were reviewed to establish the extent and rate of new bone in-growth. Functional outcomes were determined by way of self-administered questionnaires. Results: Complete records and X rays were obtained for 33 patients who underwent revision hip arthroplasty with impaction bone grafting of the acetabulum using frozen, irradiated allograft bone. There were no complications associated with the bone grafts and no patient required a re-operation. Review of serial X rays conþrmed in-growth of host bone and the functional outcome was satisfactory. Overall 29 patients (88%) declared themselves satis-þed with the outcome of their operation and 32 patients (97%) improved functionally after the operation. Conclusions: These results indicate that satisfactory results can be achieved with impaction bone grafting using frozen, irradiated allograft bone. The use of irradiated bone graft can potentially reduce the risk of disease transmission from donor to recipient without compromising the surgical results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 51 - 51
17 Apr 2023
Al-Musawi H Sammouelle E Manara J Clark D Eldridge J
Full Access

The aim is to investigate if there is a relation between patellar height and knee flexion angle. For this purpose we retrospectively evaluated the radiographs of 500 knees presented for a variety of reasons. We measure knee flexion angle using a computer-generated goniometer. Patellar height was determined using computer generated measurement for the selected ratios, namely, the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. A search of an NHS hospital database was made to identify the knee x rays for patients who were below the age of forty. A senior knee surgeon (DC) supervised three trainee trauma and orthopaedics doctors (HA, JM, ES) working on this research. Measurements were made on the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. The team leader then categorised the experimental measurement of patients’ knee flexion angle into three groups. This categorisation was according to the extent of knee flexion. The angles were specifically, 10.1 to 20, 20.1 to 30, and 30.1 to 40 degrees of knee flexion. Out of the five-hundred at the start of the investigation, four hundred and eighteen patients were excluded because they had had either an operation on the knee or traumatic fracture that was treated conservatively


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2022
Bell J Owen D Meek K Terrill N Sanchez-Weatherby J Le Maitre C
Full Access

Background. An improved understanding of intervertebral disc (IVD) structure and function is required for treatment development. Loading induces micro-fractures at the interface between the nucleus pulposus (NP) and the annulus fibrosus (AF), which is hypothesized to induce a cascade of cellular changes leading to degeneration. However, there is limited understanding of the structural relationship between the NP and AF at this interface and particularly response to load. Here, X-ray scattering is utilised to provide hierarchical morphometric information of collagen structure across the IVD, especially the interface region under load. Methodology. IVDs were imaged using the I22 SAXS/WAXS beamline at Diamond Light Source. Peaks associated with the D-banded structure of collagen fibrils were fitted to quantify their azimuthal distribution, as well the magnitude and direction of internal strains under static and applied strain (0–20%). Results. IVD tissue regions exhibited structural “AF-like” and “NP-like” fingerprints. Demonstrating high internal strains on collagen fibres particularly within the NP region of the disc. AF and NP regions showed distinct collagen orientation and internal strains with an apparent lack of bracing structure seen at the interface between the differential mechanical tissues. X-ray scattering under tensile strain provided structural information at high resolution, with clear differences observed between normal and degenerate discs under load. Conclusion. X ray scattering has been utilised to develop an improved understanding of collagen structure across the intervertebral disc which can be utilised to gain an increased understanding of load induced propagation of micro fissures and disc degeneration. Conflict of Interest: No conflict of interest. Funding: BioPro Network, UCL for funding this study through support from the MRC (MR/R025673/1)


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 276 - 276
1 May 2006
Kumar V Attar F Savvidis P Anderson J
Full Access

Aim: Assessing Polyethylene wear is very important in following up patients after Total hip replacement (THR) and Livermore method (using callipers) is routinely used by clinicians in calculating this wear. Our aim was to assess if ‘Imagika’, a new computer software programme can accurately assess polyethylene wear(PE-wear). We also compared the computer software with the Livermore method in calculating wear. Method: We used 15 different THR X rays of patients who had an ABG total hip replacement done. X rays that were included for the calculations were taken at different time intervals following the operation. Wear was calculated on each X ray by 3 clinicians using both the methods, on 3 separate occasions. We compared the Livermore method and the computer software for consistency of measurements and also calculated the inter and intra observer variability for both. Results: There was a statistically significant difference (at the 5% level) between the measurements taken by the Imagika software and the Livermore method. F(1,88) = 5.38, p< 0.05. There was a statistically significant difference in the inter-observer measurements using the Livermore method. F(2,42) = 4.18, p< 0.05, but there was no significant inter-observer variation using the Imagika computer software. There was no statistically significant difference (at the 5%level) in the intra-observer variability of both groups. Conclusion: The Imagika computer software proved to be better than the Livermore method in calculating wear with regards to inter-observer bias. There was also a significant difference between measurements taken using both methods. We conclude that the computer software may be a more accurate tool in the assessment of PE-wear in the future


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 151 - 151
1 Mar 2009
MAINARD D GALOIS L VALENTIN S GASNIER J EGROT C DILIGENT J
Full Access

Introduction: A good cup positioning requires reliable anatomical landmarks expecially for navigation. The anterior pelvic plane (APP) seems to be a good reference for navigation because it is in relation with pelvic tilt which do affect the position of the cotyle and consequently the position of the cup. The value of this plane is not well known according to gender, age, weight… The aim of the study is to assess radiologically the APP in standing and supine position before and after total hip arthroplasty. MATERIALS AND Methods: 92 Patients (32 males, 60 females, mean age 65 years) underwent strict lateral X-rays in standing and supine standardized position. Uninterpretable or unsatisfying X rays were withdrawn. 45 patients underwent a standing X-ray, 24 a supine X-ray, 21 a supine and standing X ray. Statistical analysis used a Student t-test. Results: Non matched values showed a retroversion of the pelvis of 6.4° (+/− 6.9) in supine position, 0.3° (+/− 7.4) in standing position. Matches values showed an retroversion of the pelvic of 6.9° (+/− 5.3) in supine position, 0.3° (+/− 5.03) in standing position (significant difference). Extreme values varied from −15° to + 18° (3 patients showed no variation, 2 patients a retroversion from supine to standing position). There was no statistical difference between male and female but a statistical differences in females. Discussion: The APP is easily assessable by X rays in standing as in supine position. Bony landmarks of the plane are also assessable by navigation tools and to can be a good plane as reference. Several authors showed the repercussion of the pelvic tilt on the cotyle position. The difference between standing and supine position is about 6°. But for some patients the difference is may be of 20°and that could explain some impigment and instability. A cup well positioned in supine position may be not so good in standing position because of the pelvic tilt. Conclusion: The value of the APP is important to know before THA and seems to be a good plane as reference for navigation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 326 - 326
1 May 2010
Oburu E Oroko P
Full Access

Patients with osteoarthritis of the knee reviewed by the General practioners, are usually referred for further management to the orthopaedic surgeon. It was our observation that patients were usually referred with supine knee X-rays. This meant weight-bearing films were repeated at the clinic. Methods: We sent out questionnaires to GPs inquiring whether they asked for X-rays of the knee prior to patient referral and whether they asked for weight bearing films. We also reviewed the policy in one National Hospital Service trust and one teaching hospital with regards to GPs asking for weight bearing films. The time patients spent waiting at the X-rays department was noted. Finally we inquired about the cost of a knee X-ray. Results: A total number of 65 questionnaires were sent and the response was 44 i.e. 67%. 80% of the GPs asked for non weight bearing X-rays prior to referral. Only 5% asked for weight bearing films. The radiology departments of hospitals in one NHS trust and the teaching hospital did not accept weight bearing requests from GPs. The time taken for a patient to get an X ray in the department was at least 30 minutes and the cost of X rays of the knee was £51. With an average of two patients with osteoarthritis of the knee per clinic, the cumulative waiting time for repeated X-rays was 1 hr per clinic, 5 hrs per week and 240 hrs per year. With an average of two X rays per clinic the cumulative cost was £102 per clinic, £510 per week and £24480 per year. Discussion: Non weight bearing X-rays of the knee do not add any value in making or confirming a diagnosis of osteoarthritis yet they are costly both in terms of time and money. Weight bearing films were repeated for patients with these X-rays. The cumulative cost in terms of time can be better used to review other patients and therefore reduce the waiting time before surgeons can see referrals. The other issue is the cumulative cost which can be put to better use in the trust. The time wasted by the patients who have repeated X-rays was not considered, but is also of importance. Conclusion: Patients with osteoarthritis of the knee should have weight bearing films from the initial onset. This will save time for the patient and the surgeon and will save the hospital money


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 153 - 153
1 Jul 2002
Sampathkumar K Andrew JG Vail A Craddock E Davis J
Full Access

The best follow up strategy after hip replacement (THR) is unclear. There are conflicting demands to obtain early diagnosis of loosening, and to minimise clinic visits. It would be desirable to achieve follow up with a validated symptom questionnaire alone, but it is unclear how frequently THRs are asymptomatic during early loosening. This study examined the relationship between patient reported symptoms after THR using two measures (Oxford Hip Questionnaire (OHQ) and Visual Analogue Scale (VAS)), and the classification of the patients AP x ray of the hip as having definite loosening, possible loosening, or a sound implant. We examined data from 325 patients who had undergone a standard Charnley THR for osteoarthritis. Patients had a mean follow-up of 85 months (range 24–144). X rays were examined by a single Consultant Orthopaedic surgeon, and classified as satisfactory, possible loosening or definite loosening. As expected, the large majority of patients had a satisfactory appearance on x-ray at all-time points. 12 patients were classified as having definite loosening on the basis of the available x-rays. 8 of these were subsequently listed for revision surgery at review. 20 patients were noted to have evidence of possible loosening. Examination of the Oxford hip questionnaire and VAS data demonstrated a strong relationship between OHQ value and the VAS result for pain (r = 0.78, p < 0.001, Spearman rank correlation). Data were analysed separately (using ROC curves) to determine whether the OHQ or VAS was a satisfactory method of selecting patients who fell into “definite loosening” or “definite or possible loosening” groups. Neither OHQ or VAS were sensitive or specific for definite or possible loosening. We conclude that x rays are required for early detection of loosening, and that follow up by OHQ or VAS alone is insufficient for this purpose


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 17 - 17
1 Nov 2015
Jeans E Syed A Mohammed A
Full Access

Introduction. Magnetic resonance arthrogram (MRA) is the investigation of choice in young adults with symptoms of femero acetabular impingement. The aim of the study is to assess the accuracy of MRA when correlated with surgical findings on hip arthroscopy. Materials and Method. Between June 2007 and January 2014, 136 patients had MRA followed by subsequent arthroscopy at our institution. The radiology information system was used to gather MRA data. All scans were reported by a consultant radiologist with a specialist interest in musculoskeletal radiology. Patient records were reviewed to gather surgical data. Assessment was made of labral injury, Camshaft (CAM) or Pincer lesion and degeneration of the cartilage. Results. Mean age at MRA was 34.5 years with a 2.5:1 female to male ratio. For labral pathology sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89, 100, 100 and 22% respectively. For CAM (62, 80, 79 and 64% respectively) and Pincer lesions (15, 84, 81 and 18% respectively). MRA was specific for picking up Grade 3/4 degenerate changes in the articular cartilage (92.2%) but was not as sensitive (60%), PPV 55 and NPV 94. Conclusion. These findings demonstrate that MRA is a sensitive and specific imaging modality for assessing the labrum and articular surface, but not as good for assessing CAM and Pincer lesions. This could be due to the static nature of the MRA or a lack of firm definition as to what constitutes a CAM or Pincer lesion leading to under reporting. This maybe better assessed with plane X ray or Computed tomography with 3 dimensional reconstruction. Further to this it would be interesting to combine the plane X ray and MRA finding and see if sensitivity and specificity was improved


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 63 - 63
1 Nov 2021
Visscher L White J Tetsworth K McCarthy C
Full Access

Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg x ray films available at a major metropolitan trauma center over a 12-year period. Images were screened for inclusion and exclusion criteria, namely patients >10 years after traumatic long bone fracture without contralateral injury or arthroplasty to give 39 cases. Alignment was measured according to established surgical standards on long leg films by 3 independent reviewers, and arthritis scores Osteoarthritis Research Society International (OARSI) and Kellegren-Lawrence (KL) were recorded independently for each compartment of both knees. Malalignment was defined conservatively as mechanical axis deviation outside of 0–20 mm medial from centre of the knee, to give 27 patients. Comparison of mean compartmental arthritis score was performed for patients with varus and valgus malalignment, using Analysis of Variance and linear regression. Results. In knees with varus malalignment there was a greater mean arthritis score in the medial compartment compared to the contralateral knee, with OARSI scores 5.69 vs 3.86 (0.32, 3.35 95% CI; p<0.05) and KL 2.92 vs 1.92 (0.38, 1.62; p<0.005). There was a similar trend in valgus knees for the lateral compartment OARSI 2.98 vs 1.84 (CI −0.16, 2.42; p=0.1) and KL 1.76 vs 1.31 (CI −0.12, 1.01; p=0.17), but the evidence was not conclusive. OARSI arthritis score was significantly associated with absolute MAD (0.7/10mm MAD, p<0.0005) and Time (0.6/decade, p=0.01) in a linear regression model. Conclusions. Malalignment in the coronal plane is correlated with worsened arthritis scores in the medial compartment for varus deformity and may similarly result in worsened lateral compartment arthritis in valgus knees. These findings support the mechanical hypothesis that arthritis may be related to altered stress distribution at the knee, larger studies may provide further conclusive evidence


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 1 - 1
1 Jan 2016
Shah A
Full Access

Introduction. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one such important factor to achieve satisfactory flexion. Aim. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria:. Patients who had previous bony surgery on lower end femur. Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by a Physiotherapist with the help of a Goniometer. Results. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral x ray. Pre and post op flexion was measured. Results showed that variation in the posterior femoral offset by > 3mm in post op x ray was related to loss of flexion of an average 21 deg. (16 – 24 degrees). Greater the deflection from the normal offset, greater was the loss of flexion. These patients also showed lesser improvement in KSS functional score. Discussion. Flexion is one of the most important yardsticks for the measurement of success of TKR. This factor is more important more so in Asian population. Literature has shown that three important determinants for good flexion are…. Posterior Condylar Offset Restoration. Tibial slope restoration. Femoral Roll back in flexion. An increased offset permits greater flexion before impingement between the tibial insert and the femur. In our study we kept Tibial slope and Femoral Roll back constant by using the same prosthesis. The femoral condylar offset changed as per the size of the AP femoral cutting block. (Anterior referencing guide used). Overresection of the posterior condyles reduced the posterior femoral condylar offset and hence significant loss of post op flexion. The shorter posterior condyle of smaller femoral component can increase the potential for bone impingement proximal to the posterior condyles. In our study the opposite side replaced knee acted as a control. It is generally stated that after a TKR flexion can improve upto 1 year and hence was taken as final possible flexion. Conclusion. Keeping Tibial slope and Femoral roll back constant during the surgery, posterior condylar offset restoration within 3 mm of its original pre op offset was necessary to achieve satisfactory flexion at 1 year. Undersizing the femoral component to achieve more flexion is perhaps suboptimal. Appropriate AP femoral sizing is a must to restore the normal offset


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 233 - 233
1 Mar 2004
Benareau I Tests R Lerat J Moyen B
Full Access

Aims: Functional results of anterior cruciate ligament (ACL) is closely related to the anatomical position of the graft. Femoral or tibial miss placements are associated with increase laxity, decrease range of motion. Based on anatomical dissections we developed a triangle method able to be used as fluoroscopic intra-operative landmark to increase the reproductibility of the placements. Methods: A lateral X ray of normal knee is mandatory before the surgical procedure. During the ACL reconstruction using patellar tendon a pin is placed to determine the tibial tunnel, and a small screw is inserted at the femoral ACL location. Under imagine intensifier, a lateral X ray of the operated knee is realised. The picture is exported and analysed on a PC computer. The surgical placement is compared with the ACL center position according to the triangle method. 35 knees have been operated and compared with 35-paired knees operated with the same technique and operator. Results: The mean distance between the ACL center and the surgically chosen femoral position is 7.5 ± 1.9 mm for the standard surgery and 4.9 ± 1.3 mm for the fluoroscopy based surgical navigation. The Wilcoxon test for small-paired series indicates a statistical significance (p=0.001). The mean extra operative time is 15 ± 7mn. Conclusion: This technique is simple, easy and rather fast. It gives to the surgery a significative improvement for positioning the ACL graft on the femoral side. It has to be confirmed for larger and by long term clinical results


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 337 - 337
1 Jul 2008
Yousuf M Shankarappa YK
Full Access

The authors report their preliminary experience with a minimum of one year follow –up of hydroxyapatite coating as the means of fixation of the femoral head in hip resurfacing. Between Dec 2003 and Dec 2004, of the 23 cases performed by the senior author,22 were available for follow up,15 were women (68.2%) and 7 were men (31.8). The femoral and acetabular components of the uncemented version of the CORMET 2000(Corin,Cire ncester,UK) were used. The surgical approach was the Hardinge approach in all cases. Patients were assessed pre-operatively for pain and function,using the Harris Hip Score. Post operatively they were assessed in clinic with x rays at 6 weeks,6 months and annually thereafter. X rays were evaluated for pre and post op neck shaft angle,giving an indication of varus or valgus placement of the head prosthesis. The lateral view was assessed to reveal anterior or posterior tilting of the prosthesis. Neck thinning was evaluated by measuring the ratio of the metal cup and bony neck diameters at the cup neck junction, recorded post op and at one year. None of the femoral implants were placed in varus. Only one case had inferior notching, which had remodelled at one year. In the lateral view none of the cups showed a displacement of more than ten degrees in the AP direction. There were no stem lucencies or signs of femoral implant migration in any of the cases. None of our cases showed neck thinning (change in ratio greater than 10%). Uncemented femoral implant in a metal on metal resurfacing hip replacement appears to perform well and shows no catastrophic problems at the short term one year follow up. Longer follow up studies are necessary


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 72 - 72
1 Mar 2005
Orsoni N Fiorenza F Dmytruk V Camezind-Vidal M Castaing F Moulies D
Full Access

Introduction: Acute elbow trauma is commonly seen in the emergency department. The purpose of the present study was to evaluate in our emergency department the assessment of elbow trauma radiographs in children. Methods: 136 patients aged between 0 and 16 presented at our institution for an elbow trauma over a 6 months period. All the radiographs were digitalised and stored in a commercially available computerised X ray system. All the radiographs were reviewed at the daily clinical radiological conference by an orthopaedic surgeon and a radiologist. Results: There were 64 fractures, 2 dislocations, 37 radial head subluxations and 33 simple contusions. Of these, 15 (11 per cent) were considered to have been misinterpreted. There were 12 undisplaced fractures (5 supra-condylar fractures, 3 radial head fractures, one fracture of the lateral condyle, 3 fractures of the olecranon and 3 false-positive diagnoses of fractures. All patients were reviewed within a few days and were correctly reassessed and treated. Conclusions: Compared to other fractures, children’s elbow trauma are commonly misdiagnosed in the emergency department. In this short series, correct diagnosis was missed 15 times (11%) by various physicians working in the Emergency Department (trainees, emergency physicians). The senior specialists (orthopaedic surgeon and radiologist) used real time digital contrast enhancement, as well as magnification and soft tissue assessment with the digitizer to correctly analyse the missed diagnosis. X ray review by senior specialists at the daily clinical radiological conference is time consuming and sometimes difficult but appears to be clearly beneficial to patients ‘care


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 246 - 247
1 Mar 2004
Benareau I Chalencon F Lerat J Moyen B
Full Access

Aims:ACL revision surgery is a second-generation type of knee ligament surgery. The artificial ligaments, the imperfect mastering of arthoscopic assisted surgery and the absence of clinical and radiological analysis of peripheral laxities are among the main factors for failures. Methods:43 patients of a mean age of 29y were previously operated between 1 and 5 times.14 artificial ligaments, 23 patellar tendons and 4 hamstrings tendons failed as a first ACL reconstruction. The mean time between the first operation and the index revision was 44 months. In 6 cases an additional HTO was used. Different tendon grafts were used: quadriceps 11, patellar 19 and hamstrings 8. In 3 occasions an additional extra articular reefing was used. The patients were reviewed by one independent observer using KT 1000, Stress X rays, IKDC form (2000). The mean follow up is 35 months (11–123)Results:The IKDC score in pre operative time was 19 D, 21 C and 1B. At the review the score is 2A, 28 B, 9C, 2D. The functional IKDC form show 37.5% of remaining pain, 44% of stiffness sensation and 12.5% of instability. The mean functional improvement is 44%. The mean laxity improvement is 5.3mm for KT1000 and 4.5mm for stress X rays. Conclusions:Revision ACL surgery is not as good as primary surgery. The reconstruction is technically difficult and must be ‘à la carte’ in order to take in account several simultaneous problems: bone defect, cartilage abnormalities, skin and ligament insufficiencies


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 207 - 207
1 May 2009
Ali SA Ahmed J Siddiqi N Mullins V Rahmani K Shafqat SO
Full Access

Background: Over many years our understanding of fracture patterns and management has evolved. One of the biggest steps was the adoption of the principles of fracture fixation as described by the Arbitsgemeinschaft fur Osteosynthesefragen (AO). The application of this philosophy has allowed us to optimise fracture management and improve outcome. In our unit we noted a number of complications resulting from suboptimal fracture fixations of ankles some of which required revision. It was decided to review fracture fixation of ankles in the unit to see whether the basic principles of fixation was being followed in our DGH. Aim: To evaluate whether the AO principles of fixation for ankle fractures are being followed in our local unit. Patients and Methods: 52 consecutive patients over a period of 1 year from August 2005 to August 2006 with bi malleolar and isolated medial malleolar ankle fractures, requiring surgery, had their case notes and pre operative x rays reviewed retrospectively looking at fracture patterns according to the AO and Weber classification. Post operative x rays where reviewed to see if the principles of facture fixation had been appropriately followed. Results: Of the 52 patients evaluated 26 were Weber type B fractures, 20 were type C and 6 were isolated medial malleolar fracture. Nine of the type B and three of type C (23% of the total number) underwent fixation not in accordance with AO principles. In every case the fibula fixation did not include a cortical lag screw. Discussion/Conclusions: Although none of the 12 described had to undergo revision, their management was far from optimum. By ensuring that operating surgeons have the appropriate training and experience in basic fracture fixation before being allowed to undertake such procedures, our unit hopes to show an improvement on these figures by the time this audit is repeated


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 301 - 301
1 May 2006
Komarasamy B Braybrook J babu VL
Full Access

Objective: We report an unusual presentation of telangiectatic osteosarcoma of distal femur in a preadolescent boy. Methods: A 9 year old boy fell down heavily while he was on holiday and fractured his distal femur. He was given above knee plaster locally and then transferred him to hospital where he lives normally. He developed increasing pain over next two weeks over fracture site (4 weeks after injury) and was reviewed in clinic. X ray of his femur showed permeative pattern of bone destruction with new bone formation. Subsequent biopsy of his lesion confirmed telangiectatic osteosarcoma. His subsequent MRI scan of thigh and CT scan of his chest showed pulmonary metastasis and dissemination of tumour to proximal femur. He never noticed any pain, discomfort or swelling before fracture and until four weeks after fracture apart from symptoms of fracture. Retrospective review of his x ray which was taken at the time of fracture demonstrated not very obvious osteolytic lesion in distal femur. Conclusion: Telangiectatic osteosarcoma is a rare subtype of osteosarcoma and represents nearly 2% of all osteosarcomas. The incidence peaks in early to mid-adolescence and is not commonly encountered in very young and preadolescent patients. Osteosarcoma usually presents with pain at night and precedes tumour by weeks or months. Some times there may be only a history of a tired feeling, a slight limp or a history of trauma. Our case did not have any symptoms at all until two weeks before the presentation. The fracture made the tumour extra compartmental and led to metastasis and poor prognosis. We should always aware of this possibility of rare presentation when we see a preadolescent patient with increasing pain following fracture


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 88 - 88
1 Jan 2004
Rahmat R Moore RJ Nikoloff S Matsacos D Oakes BW Fraser RD
Full Access

Introduction: The development of laboratory techniques in the last ten years has enabled the successful harvest, in vitro selection, culture and transplant of chondrocytes. The study proposes that transplantation of autologous chondrocytes prevents degeneration of the intervertebral disc following outer annular injury in an ovine model. Methods: Eight sheep were anaesthetised and five contiguous lumbar discs were exposed via a left-sided posterolateral approach. Four of the animals were given full thickness annular incisions in three alternate discs. No annular incisions were made in the other 4 sheep. Costal cartilage was harvested from the left twelfth rib of all animals. Tissue was cultured and the chondrocytes were labelled in vitro with CFSE for verification following transplantation. Six weeks later autologous cultured chondrocytes were injected into the lower two alternate discs of all animals, leaving the uppermost discs and those untouched in between as internal controls. Animals were sacrificed after three, six, twelve and twenty-four weeks. Results were based on X rays, histological, and immunocytochemical assessments. Results: Preliminary histological results up to three months showed viability of cultured chondrocytes and matrix production post transplantation. Serial X rays suggested that progressive disc degeneration was arrested in the treated discs. Discussion: In this pilot study we have shown that cultured autologous chondrocytes can remain viable long term in vivo. These preliminary results suggest that these transplanted chondrocytes have the ability to retard and possibly prevent disc degeneration following annular incision. Previous similar studies have reported the use of chondrocytes cultured from disc, whilst this study showed that chondrocytes from a source foreign to the disc can exert positive effects. The encouraging result from this pilot study needs to be further validated to realise its potential as a treatment for degenerative disc disease


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 528 - 528
1 Dec 2013
Shah A
Full Access

Introduction:. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one of the important factors to achieve satisfactory flexion. Aim:. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods:. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria: . 1). Patients who had previous bony surgery on lower end femur. 2). Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by an independent Physiotherapist with the help of a Goniometer. Results:. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral x ray. Pre and post op flexion was measured. Results showed that variation in the posterior femoral offset by > 3 mm in post op x ray was related to loss of flexion of an average 21 deg. (16–24 degrees). Greater the deflection from the normal offset, greater was the loss of flexion. These patients also showed lesser improvement in KSS functional sco. Discussion:. Flexion is one of the most important yardsticks for the measurement of success of TKR. This factor is more important more so in Asian population. Literature has shown that three important determinants for good flexion are…. . 1). Posterior Condylar Offset Restoration. 2). Tibial slope restoration. 3). Femoral Roll back in flexion. An increased offset permits greater flexion before impingement between the tibial insert and the femur. In our study we kept Tibial slope and Femoral Roll back constant by using the same prosthesis. The femoral condylar offset changed as per the size of the AP femoral cutting block. (Anterior referencing guide used). Overresection of the posterior condyles reduced the posterior femoral condylar offset and hence significant loss of post op flexion. The shorter posterior condyle of smaller-sized femoral component can increase the potential for bone impingement proximal to the posterior condyles. In our study the opposite side replaced knee acted as a control and hence eliminating patient bius. It is generally stated that after a TKR flexion can improve upto 1 year and hence that was taken as final possible flexion. Conclusion:. Keeping Tibial slope and Femoral roll back constant during the surgery, posterior condylar offset restoration within 3 mm of its original pre op offset was necessary to achieve satisfactory flexion at 1 year. Undersizing the femoral component to achieve more flexion is perhaps suboptimal. Appropriate AP femoral sizing is a must to restore the normal offset


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 159 - 159
1 May 2011
Adam P Ehlinger M Taglang G Moser T Dosch JC Bonnomet F
Full Access

Introduction: Preoperative use of tomodensitometry is a common practice when assessing fractures with intraarticular involvement, helping to determine the most appropriate surgical approach according to the lesions observed. To date, during the surgical procedure itself, radiographical or fluoroscopic controls still largely rely on two dimensions X rays. We assessed the possible benefits of intraoperative tridimensional reconstructions using mobile isocentric fluoroscopy (iso-C-3D) after one year of use. Material and Methods: All the procedures where intra-operative tridimensional fluoroscopy was used were assessed prospectively for one year. The type of osteosynthesis as well as specific modalities of installation and therapeutic measures driven from analysis of the images were analyzed. Results: During the first year of use, intraoperative tridimensional reconstruction had been carried out in 48 procedures in 47 patients. The region involved was calcaneus 13 times, thoracolumbar spine 12 times, acetabulum 11 times, tibial condyles 9 times, axis 2 times and pelvis one time. Installation was the same than usually performed in the cases of calcaneus and axis osteosynthesis. For the other localisations, obtention of good quality images was facilitated through the use of a carbon table for spine and osteosynthesis of the tibial condyles, and through the use of a carbon traction table for acetabular or pelvic fractures. Intraoperative tridimensional reconstruction allowed to check for freedom of the vertebral canal after reduction and osteosynthesis of the spine. in the cases of fracture of the calcaneus, reduction of one thalamic fragment was improved in one case and one intraarticular screw could be changed in another case. In the case of acetabular surgery, one screw stabilizing the posterior wall was found intraarticular on tridimensional reconstruction and could be changed before closure. Discussion: Intraoperative tridimensional reconstruction, during its first year of use, allowed to avoid 3 early reinterventions (for 2 calcaneus and one acetabulum). Accurate interpretation of standard plain X ray in these two localizations is difficult because of the spherical shape of the hip joint and because good quality imaging, especially the retrotibial view, is hardly obtained intraoperatively in fractures of the cacaneus. When using tridemensional reconstructions, acquisition of good quality images has to be anticipated during the installation of the patient, limiting any interfereces with metallic supports to a minimum. Conclusion: the results obtained over the first year of use of intraoperative tridimensional reconstructions with the ISO-C-3D encouraged the authors to generalize its use when performing osteosynthesis of the acetabulum or calcaneus as well as percutaneus osteosynthesis of articular fractures


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 153 - 153
1 Apr 2005
Shah AH Sunderam R Parkinson RW
Full Access

Introduction: As the age for performing a primary knee replacement is gradually falling there is increase need and demand for revision total knee replacement and subsequent revisions thereafter. There are very few published studies showing the outcome of re revision knee replacement surgery. Aim: We aim to show functional outcome of 21 patients at 3 to 5 years after undergoing Re revision knee arthroplasty. Methods: We defined re revision as a procedure where there was exchange of either one or both Tibial and Femoral components using a modular revision system. We included all patients undergoing re revision knee replacement and had complete records & X rays . We excluded patients with incomplete records, those who could not be assessed due to medical infirmity or other reasons. We also excluded patients with 2 stage revision knee replacement for infection. This left us with 21 patients in our cohort operated between 1996–2002. The patients were scored pre operatively using Knee society score ( KSS) and Western Ontario and McMasters Osteoarthritis Index (WOMAC). Patients were assessed with same scoring system post operatively at 3 months, 1 year and annually there after. Post op x rays were reviewed by Knee society Radiological Evaluation. Results: 18 modular revision prosthesis ( Co ordinate ultra, DePuy) and 3 rotating hinge (S Rom) prosthesis were used. The mean follow up was 3.5 years range from 11 months to 5.7 years. The mean post operative KSS score improved to 83 from pre op 41. Final post operative WOMAC scores for pain 12.3, Stiffness 5.6, Function are 47.1. We had few minor complication not requiring further surgery. Overall in 15 patients (71.43%) had a statistically significant improvement at latest follow up. 4 patients (19%) had moderate improvement and 2 patients ( 8%) had no improvement in scores. Conclusion: We conclude that re revision knee arthroplasty provides satisfactory pain relief and knee stability. As 71% of our cohort improved significantly we continue to support the clinical use of this procedure


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 59 - 59
1 Mar 2006
Mattes T Puhl W
Full Access

Objectives/Background: Long-term outcome in THR is multifactorial influenced. Malpositioning leads to complications as early loosening, leg length difference or dislocation of the artificial joint. A proven factor for early losening is a misplacment of the center of rotation or varusposition of the stem. A higher luxation risk results out of high inclination and anteversion angles an reduced soft tissue tension. Aim of this study was to prove the image free navigation software in the modular Navitrack-System to check the implant position based on anatomical intraoperative acquired data. Design/Methods: In 35 consecutive cases we implantet the ACA screwcup and the Optan anatomical stem with use of the Navitrack navigation System. The software calculates al relevant data out of intraopertive probed landmarks. Intraoperative the shifting of the center of rotation, the cup anteversion and inclination, the stem inclination and torsion and the leglength shift is shown in real time. Intraoperative data were compared with postoperative position measurement in plain X-rays and in 15 patients in postoperative CT scans. Results: In all cases navigated implantpositioning was possible. In 3 cases stem positioning was not possible cause of refference loosening. Mean inclination of the cup as shown in the Navigation System was 52 (range 45 – 58 ), mean anteversion was 11 (range -5 – 27). Mean postoperative inclination measured on postoperative X-Ray was 53,8 (range 49 – 60). The difference between the shown values from the CAS System to the postoperative X Ray for the inclination was 1,8 (range -9 – 6). The leg length difference on postoperative X-ray was in mean 3,1 mm, on screenshots 2,8 mm. The difference between screenshot and X ray was in mean 0,83 mm. Conclusions: This study shows, that with the CT free software for the Navitrack-System reliable cup and stem navigation is possible. Whenever the hip joint allows to probe a spherical segment in the femoral head or acetabulum navigated THR is possible without the need of intraoperative fluoroscopy or preoperative CT scan. For leg length control and cup Inclination the data are still promising. Further investigation is necessary for stem axis and cup anteversion according to the navigation based reference coordinate system. Whenever no geometric sphere existent, e.g. severe hip dysplasia, the system must be developed as a hybrid system with CT (NMR) based cup and image-less stem navigation


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 254 - 254
1 May 2006
Ahluwalia R Allen P
Full Access

Introduction: An accepted treatment of lateral compartment osteoarthritis with valgus deformity is to correct the malalignment, and unload the affected compartment. Previous techniques have used large fixation plates to secure complete osteotomy sites. We present a prospective study using a novel incomplete opening wedge osteotomy, in treating lateral compartment osteoarthritis in active patients younger than 65. Methods: We assessed all patients (n=26) who underwent opening wedge femoral osteotomy with Puddu plate fixation over a 5 – year period by one surgeon (PRA). All patients had long leg X rays and arthroscopic evaluation; revealing either grade 3 and 4 osteoarthritis within the lateral compartment; 11 secondary to lateral menisectomy, 4 to complex trauma to the lateral tibial plateau, the others were diagnosed with primary osteoarthritis. Pre operative and post-operative Knee Society and Oxford Knee scores and long leg X rays were used to monitor subjective and functional improvement. Results: Patients had a mean age of 48, (mode 56); ASA of 1 (range 1–2); and BMI of 24 (range 20–26). Mean follow up time was 46.8 months (6–62 months). Results in table 1 show early benefits in post-operative pain and improved function scores, which were maintained to 42 months. All patients had radiological union by 3 months (2–8months). Plates were removed as a minor procedure in some patients at 8 months (6–18 months), and did not lead to loss of correction or conversion to total knee replacement within the study. Subjective and functional progress was observed by using the Oxford Knee Score and the Knee Society Score, early results showed an improvement from in the Oxford Knee score from 54.4 (+/−5.7) to 27.2 (+/−4.7)*, and the improvement was maintained at 12**, 30**, and 62** months (*P< 0.002; **P< 0.005). The same pattern was repeated with the knee society score where a pre opetrative score of 53.9 (+/−4.8) improved to 87.6 (+/−6.2) at 6 months and was 82.4(+/−8.7) at 62 months. No infections were recorded, or differences in pre and post-operative flexion were observed at 36 months (P< 0.005) in all patients. However, 3 patients required further manipulation to overcome post-operative stiffness. Plates were removed only for local discomfort, and follow up showed there was no loss of corrective angulation. Conclusion: These results suggest using the puddu plate is an alternative to unicompartmental or total knee arthroplasty in young active patients with lateral compartment osteoarthritis, without significant morbidity


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 4 - 5
1 Jan 2003
Reed A Joyner C Isefuku S Brownlow H Simpson A
Full Access

Atrophic non-unions are usually attributed to impaired blood supply but the events that lead to atrophic non-union remain poorly understood. Recent studies. 1,. 2. have shown that vascularity is not reduced in established non-unions but these studies have not examined vascularity at an early stage. The aims of this study were to: 1) develop and validate a clinically relevant small animal model of atrophic non-union and 2) test the hypothesis that the vessel density of atrophic non-unions reaches that of normal healing bones but at a later time point. Twenty eight adult female Wistar rats underwent application of a novel circular frame external fixator to the right tibia under general anaesthesia. The fixator construct was standardised, with eight needles that were drilled through the skin into the proximal and distal metaphyses of the tibia. An osteotomy was performed with a 1mm burr under irrigation. The periosteum was removed on 14 of the 28 animals using a scalpel and the intramedullary canal was curetted. Both insults were performed proximally and distally for a distance equivalent to 1 diameter of the tibia. A 1mm gap was introduced at the osteotomy site and the wound was closed. Once the animal had recovered it was allowed unrestricted weight bearing. Anteroposterior X rays were performed every 2 weeks. Animals were killed at 1, 3, 8 and 16 weeks. Callus areas were measured from X rays using an image analysis system. The average callus area was calculated for each rat every 2 weeks as an indicator of callus production. Specimens were fixed, decalcified, embedded in paraffin wax and 6 ìm sections were stained with H& E. Vascularity was assessed immunohistochemically with monoclonal antibody against smooth muscle actin. The total number of blood vessels in the interfragmentary gap was counted. At 8 and 16 weeks post-osteotomy all animals where stripping and curetting had been performed went on to an atrophic non-union. All animals where this was not performed went on to unite successfully. Histological observations support these radiological findings. Significantly less callus formed in the non-unions than in those that united. There were significantly fewer vessels in the non-unions at week 1 compared to the controls but, by 8 weeks the blood vessel density in the established atrophic non-unions had reached the same level as the vessel density during normal healing. An atrophic non-union model that closely resembles the clinical situation has been developed and validated in rats. The results support the hypothesis that the number of vessels in atrophic non-unions reaches the same level as in those that unite but at a later time point. It is concluded that diminished vessel density within the first 3 weeks may prevent fractures from uniting


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 74 - 74
1 Apr 2019
Micera G Moroni A Orsini R Sinapi F Fabbri D Acri F Miscione MT Mosca S
Full Access

Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this prospective study was to report the survivorship and the clinical and radiographic outcomes and the metal ions dosage of a group of patients operated with metal on PCU arthroplasty featuring large metal diameter heads, at 5 years from surgery. Study Design & Methods. 68 consecutive patients treated with the THS were included. The patients have been contacted by phone call and invited to return to our centre for clinical (Oxford Hip Score, OHS, and Harris Hip Score, HHS), radiographic exam and metal ion levels evaluation. All the patients were operated with uncemented stems. Results. The survival rate is 100% and no major complications were seen. The average preoperative OHS was 17 (6–34), at follow-up it was 44 (40–48). The average preoperative HHS was 48 (12–76), at follow-up it was 93 (84–100). On the x rays taken at follow-up, no signs of periprosthetic bone rarefaction and/or osteolysis were seen. No signs of PCU liner wear were visible. At follow up mean Co serum level was 0.52 ng/mL (<0.1–2.5, sd 0.5), mean Cr level was 0.27 ng/mL (0.1–2.2, sd 0.2). In this prospective study at a mean follow up of 5 years, all implants were well functioning, with no radiological signs of loosening and normal serum levels of cobalt and chrome. Although large diameter metal heads and metal sleeve were used no trunnionosis occurred. Conclusions. We believe that these positive outcomes are due the positive biomechanical characteristics of PCU. These results need to be confirmed at a longer follow up and in a more active younger patient population


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 117 - 117
1 Jun 2018
Whiteside L
Full Access

Stems are a crucial part of implant stabilization in revision total knee arthroplasty. In most cases the metaphyseal bone is deficient, and stabilization in the diaphyseal cortical bone is necessary to keep the implant tightly fixed to bone and to prevent tilt and micromotion. While sleeves and cones can be effective in revision total joint arthroplasty, they are technically difficult and may lead to major bone loss in cases of loosening or infection, especially if the stem is cemented past the cone. A much more conservative method is to ream the diaphysis to the least depth possible to achieve tight circumferential fixation, and to apply porous augments to the undersurface of the tibial tray or inner surface of the femoral component to allow them to bottom out against the bone surface and apply compressive load. If a robust, strong taper, stem and component combination is used, rim contact on only one side is necessary to achieve rigid permanent fixation. Porous and non-porous stems are available. The non-porous stems should have a spline surface that engages the diaphyseal bone and achieves rigid initial fixation but does not provide long-term axillary support. In that way the porous rim-engaging surface can bear compressive load and finally unload the stem and taper junction. Correctly designed stems do not stress relieve unless they are porous-coated. In situations where metaphyseal bone is not available, porous-coated stems that link to hinge prostheses are a very important part of the armamentarium in complex revision arthroplasty. Use of stems requires experience and special technique. Slight underreaming and initial scratch fit are necessary techniques. This does not result in tight fixation every time because split of the cortex does occasionally occur. In most cases these splits do not need to be repaired, but when there is a question, an intra-operative x ray should be taken and the surgeon should be prepared to repair the fracture. Stems are an essential part of revision total knee arthroplasty. A tightly fit stem in the diaphysis is necessary for fixation when metaphyseal bone is deficient. No amount of cement pressed into the deficient metaphyseal bone will substitute for rigid stem fixation


Introduction. Literature describes pelvic rotation on lateral X rays from standing to sitting position. EOS full body lateral images provide additional information about the global posture. The projection of the vertical line from C7 (C7 VL) is used to evaluate the spine balance. C7 VL can also measure pelvic sagittal translation (PST) by its horizontal distance to the hip center (HC). This study evaluates the impact of a THA implantation on pelvic rotation and sagittal translation. Materials and Method. Lumbo-pelvic parameters of 120 patients have been retrospectively assessed pre and post- operatively on both standing and sitting acquisitions (primary unilateral THA without complication). PST is zero when C7VL goes through the center of the femoral heads and positive when C7VL is posterior to the hips' center (negative if anterior). Three subgroups were defined according to pelvic incidence (PI): low PI <45°, 45°<normal PI<65° or high PI>65°. Results. Pre-operatively PST standing was −0.9 cm (SD 4.5; [−15.1 to 7.2]) and PST sitting was 1.3cm (SD 3.3; [−7.7 to 11.8]). The overall mean change from standing to sitting was 2.2 cm ([−7.2 to 17.4]) (p<0.05). Post-operatively PST standing was 0.2 cm (SD 4.7; [−17 to 8.1]) and PST sitting was 1.4cm (SD 3.5; [−7.3 to 10.4]). The overall mean change from standing to sitting was 1.2 cm ([−14.2 to 22.4]) (p<0.05). In low PI group pre and post-operatively, PST increased significantly from standing to sitting (p<0.05; with HC going anterior to C7VL). When comparing pre and post operative changes, standing PST significantly increased (p=0.001). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,01). In normal PI group pre-operatively, PST increased from standing to sitting (p=0.004). When comparing pre and postoperative changes, PST increased (p=0.006). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,04). In high PI group pre and post operatively, PST increased from standing to sitting (p=0.034) while there are no significant changes from pre to post-operative status in standing and in sitting. Discussion. Anteroposterior pelvic tilt is not the only adaptation strategy for postural changes from standing to sitting positions. Anteroposterior pelvic translation (quantified by PST) is an important adaptation mechanism for postural changes. Comparison of pre and post-operative values of PST points out the importance of pelvic translation for low and standard PI patients after THA. The anteroposterior translation appears to change significantly in different functional positions pre and post operatively. This is an important variable to consider when assessing the patients' posture change or investigating the causes of the hip dislocation after total hip arthroplasty or spinal fusion. Conclusion. Pelvic translation must be considered as a significant mechanism of adaptation after THA. Further studies are needed to study the impact on subluxation or dislocation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 15 - 15
1 Nov 2016
Sinclair V Walsh A Watmough P Henderson A
Full Access

Introduction. Ankle fractures are common injuries presenting to trauma departments and ankle open reduction and internal fixation (ORIF) is one of the first procedures targeted in early orthopaedic training. Failure to address the fracture pattern with the appropriate surgical technique and hardware may lead to early failure resulting in revision procedures or premature degenerative change. Patients undergoing revision ORIF are known to be at much greater risk of complications, and many of these secondary procedures may be preventable. Method. A retrospective analysis of all patients attending our unit for ankle ORIF over a two year period was undertaken. Patients were identified from our Bluespier database and a review of X rays was undertaken. All patients undergoing re-operation within eight weeks of the primary procedure were studied. The cause of primary failure was established and potential contributing patient and surgical factors were recorded. Results. 236 patients undergoing ankle ORIF were identified. 13 patients (5.5%) returned to theatre for a secondary procedure within eight weeks. Within this group, 7 (54%) patients returned for treatment of a neglected or under treated syndesmotic injury, 3 (23%) for complete failure of fixation, 2 (15%) with wound problems and 1 (8%) for medial malleoulus mal-reduction. Of the patient group, 5 (38%) were known type 2 diabetics. Consultants performed 2 (15%) of procedures, supervised registrars 5 (39%) and unsupervised registrars 6 (46%) operations. Conclusion. Errors are being made at all levels of training in applying basic principles such as restoring fibula length and screening the syndesmosis intra-operatively. Appropriate placement and selection of hardware is not always being deployed in osteopenic bone resulting in premature failure of fixation and fracture patterns are not being fully appreciated. Patients are undergoing preventable secondary procedures in the operative treatment of ankle fractures


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 115 - 115
1 Jan 2017
Gunzel E Gindraux F Barnouin L
Full Access

Amniotic membrane (AM) and amnion/chorion foetal membranes (ACM) are mainly composed of collagen & laminin layers and constitute relatively new materials to the dental market. They have proven effective for periodontal treatments such as Guided Tissue Regeneration (GTR) [1–3]. Based on our expertise in the field of lyophilisation & securisation of human bone allograft (Phoenix® process), we aimed to develop our own process applied to ACM and to control its in vivoefficacy in GTR indication. Human placentas were donated under informed consent. ACM were separated from placenta and processed with a proprietary AMTRIX (TBF) Process. Resulting product was called ACMTRIX. The effectiveness of ACMTRIX in GTR was evaluated using an in vivorat calvaria defect model as followed:. Empty defect (2 animals),. ACMTRIX apposed onto the defect (4 animals),. 3 Bone substitutes (allogenic – mineralized cortical bone powder (Phoenix®); demineralized cancellous bone powder mixed with hydroxyapatite and demineralized bone matrix (DBM) cancellous block) filled in the defect and covered by ACMTRIX (4 animals). One animal per study group was sacrificed after 8 weeks, all others after 8 weeks. Evaluations were performed by: macroscopic observations, X Ray micro-CT, and histological analysis. For all groups using ACMTRIX, no major sign of inflammation were observed macroscopically and histologically. Moreover, bone tissue was already mature from 8 weeks and bone filling was slight to moderate. The higher mean rate of mineralization was obtained for the group associating DBM cancellous block + ACMTRIX. Although a xenogenic material, ACMTRIX was very well integrated without significant inflammatory reaction compared to empty defect and fully integrated in subcutaneous area. The mineralization was superior with DBM cancellous block probably thanks to the stabilization of the material in the defect. Used alone, ACMTRIX has no osteogenic potential. In conclusion, ACMTRIX has the potential to function as barrier for GTR and the unique properties associated with this material can augment its potential as a matrix for periodontal regeneration


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 350 - 351
1 Nov 2002
Langlais F Lambotte J
Full Access

In early secondary arthritis due to femoral dysplasia, varus osteotomy achieves a control of arthritis for two decades in 80 % of cases : it is therefore a very reliable conservative treatment. Moreover, in carefully selected cases of severe arthritis in young active patients, a valgus osteotomy can achieve pain relief for a decade in 70 % of cases. THE VARUS OSTEOTOMY is recommended when the arthritis is due to a coxa valga ≥ 140°. By reducing the inclination angle to 125° the abductors level of arm is optimized, and their contracture is decreased. Therefore, the osteotomy reduces the surface strains, but it does not improve the extent of articular surfaces. A – . INDICATIONS. 1) Four factors are mandatory to achieve long term improvement:. The arthritis must be the . consequence. of the dysplasia, with degenerative changes localized at the supero lateral part of the head and of the acetabulum. This can be confirmed by isotope scanning. If the arthritic changes are not localised the desease is rather a primary arthritis, or an inflammatory or a metabolic disease, which are not an indication for a biomecanical treatment. There must be a real . coxa valga. , evidenced by coxometry. Anteversion is mesured by CT scan, and the inclinaison is mesured on a X ray of the pelvis with the hips in internal rotation equal to the ante-version. If there is a shortened femoral neck (such as a post reduction osteonecrosis), the modification of the glutei lever of arm may not change significantly the articular strains, and therefore osteotomy is no indicated. The articular . congruency. must not be impaired by the reduced inclination angle. Pre operative X rays with the hips in an abduction equal to the planned varisation must not reveal any lateral narrowing of the joint space, which would mean incongruity, and lead to failure. The possibility of articular . healing. must be important : varus osteotomy is recommended before 45 years, and if the joint space remains ≥ 50 % of normal. 2) Therefore varus osteotomy is . not recommended. in a non symptomatic dysplasia (as some of them may not lead to arthritis), or if the symptoms are those of a labrum syndrom, with suddent pain, instead of a progressive and mechanical arthritic pain. if the dysplasia is only acetabular : then only the acetabulum has to be treated. if the anatomic abnormality is not an increase of the inclinaison (neck-shaft) angle, but a modification of the head-neck angle, which causes impigement with the labrum, and which is not improved by inter-tro-chanteric osteotomy. 3) The . assosciated dysplasia. have to be taken into consideration. If there is a femoral hyperanteversion there are two different conditions in the adult :. if the patient walks with internal rotation of knees (convergent strabismus of patella), realising a dynamic correction of hyperanteversion, the association an external rotation of the femur to the varisation is recommended. but if, despite hyperanteversion, walking is without abnormal rotations of the knees, this means that the optimum congruity of the hip is in that position. An ostotomy is no advocated as, instead of retroversing the femoral neck, it would rotate externally the femoral shaft. If there are both an acetabular and a femoral dysplasia, they both have to be treated :. if an augmentation is recommended for an anterolateral defect, the shelf osteoplasty can be performed in the same operation that the varus osteotomy. if a medialisation is necessary (Chiari), both osteotomies can be assosciated in one stage. but if a complex reorientation osteotomy is necessary (either periacetabular –Giacometti-,. or pelvic –Ganz-), it could be hazardous to perform a varus osteotomy at the same time. B – . SURGICAL TECHNIC. The importance of the varisation depends on that of the coxa valga. The final inclinaison angle must be 125°, as the lever of arm of the abductors is impaired for a lower angle. Moreover there is a post operative limping due to the ajustement of the glutei length, the duration of which is function of the varisation (one year per 10°). To reduce this limping, only the necessary varisation has to be made. The technic has several important points :. non union is avoided by non dissection of the medial metaphysis or removal of a wedge :. we use a subperiosteal osteotomy, leaving in contact the medial cortex, with a lateral opening, fixed by a nail plate as a tension band. This technique gives a minimum limb shortening (12 mm for 15° varisation). respect of the articulation and soft tissues. There is no arthrotomy as the nail plate is inserted on a guide pin. Later implantation of the THR will not be complicated by the previous osteotomy. precise, « automatic » correction, depends only on the nailplate angle. the resistance of the osteosynthesis allows immediate rehabilitation (this extra articular operation does not reduce ROM), and 10 to 20 kilos weight bearing. Full weight bearing is authorized at three months. C – . RESULTS. There are less thant 5 % mechanical complications. An antalgic effect is obtained within some weeks. In 80 % of cases, painlessness and absence of radiological deterioration for two decades is achieved, a THR becoming necessary in the third decade. In 20 % of cases, only a temporary effect is obtained, leading to a THR after 5 to 10 years. THE VALGUS OSTEOTOMY is at present used in only seldom cases of young patients with a severely damaged articulation, but who prefer an antalgic conservative surgery than a THR, because they wish to continue for a decade a strenuous activity not compatible with an arthroplasty. This can be made only when there are two large osteophytic drops of the acetabulum and of the femoral head, which can be put into contact by the valgisation, and facilitate healing of the superior lesions. In carefully selected cases, a relief of pain is achieved for a decade in 70 % of patients. IN CONCLUSIONS. The femoral varus osteotomy remains one of the most reliable conservative operations in osteoarthritis due to DDH. However to achieve these good results, a clear understanding of the indications and biomechanical demands of this operation is required. In seldom and selected cases of severe arthritis, a palliative valgus osteotomy can achieve a decade of pain relief


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 45 - 45
1 Mar 2005
Heilpern GNA Parker BC
Full Access

We have implanted 371 CLS acetabular components in our centre since 1989. Despite design changes in the component we report 4 cases of failure by fracture through the metal backing of the cup. Our aim is to highlight this uncommon mechanism of failure and advise that in cases of unexplained hip pain in those with CLS acetabular components X rays in at least 2 planes are performed


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 5 - 5
1 Sep 2013
Lomax A Singh A Madeley N Kumar C
Full Access

A series of 76 distal tibial pilon fractures treated with surgical fixation were retrospectively reviewed from case notes, plain radiographs and CT imaging. Patient demographics, injury and fracture patterns, methods and timing of fixation and clinical and radiological outcomes were assessed over a mean follow up period of 8.6 months (range 2–30). Definitive fixation was most commonly performed through an open technique (71 cases) with plate fixation. CT imaging was used to plan the most direct approach to access the fracture fragments. Single or double incision techniques were used to access the tibia, with fixation of the fibular performed when necessary. Superficial infection occurred in 5 cases (6.9%) and deep infection in 2 (2.8%). Aseptic wound breakdown occurred in 5 cases (6.9%). The rate of wound breakdown after three-incision technique was 37.5%. There were 10 cases of non-union (13.9%) and 8 of mal-union (10.5%). Post-traumatic arthritis was present on the most recent x ray in 17 cases (23.4%). Further surgery was required in 20 cases (27.8%), most commonly for metalwork related problems and also for treatment of non-union, post-traumatic arthritis and infection. This review gives comprehensive injury specific and surgical outcome data from one of the largest reported series of these complex and problematic injuries


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 6 - 6
1 Apr 2013
Sakagoshi D Sawaguchi T Shima Y Inoue D Oshima T Goldhahn S
Full Access

Introduction. Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for TAD within 20 mm. However the definition of neck axis and the limb position of lateral radiograph are not clearly described in the original literature. We propose the refined TAD by defining these factors. The objective of this study was to analyze the interobserver agreement of this refined TAD. Materials and Method. X rays of 130 cases of unstable trochanteric fractures were used for the analysis of the refined TAD. In the refined TAD, neck axis was defined as the line between the center of femoral head and midpoint of narrowest part of the femoral neck, and lateral radiograph was taken with hip flexion 90 degrees and abduction 45 degrees. The refined TAD was independently measured by 2 experienced (observer 1,2) and 2 inexperienced (observer 3,4) orthopaedic surgeons who were trained with the new method before the measurement. Intraclass correlation coefficient (ICC [2,4]) was calculated to assess the interobserver agreement. Result. The mean refined TADs were 18.2:18.4:18.2:18.2 for observer 1:2:3:4. There was a strong correlation among all four observers (ICC 0.998, (95% CI: 0.998, 0.999). Discussion. Regardless of the clinical experience of observers, the refined TAD is a reliable tool and can be used to develop new TAD recommendations for predicting failure of fixation


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 100 - 100
1 Mar 2006
Kasis A Pacheco R Hekal W Farhan M
Full Access

We reviewed 35 patients who underwent a medial unicondylar knee replacement, with an average follow up of 4 years (for functional assessment). All patents had a weight bearing AP and lateral X rays and were clinically assessed using Hospital for Special surgery score, Bristol Knee Score and SF 36 health assessment form. Five angles were measured on the x-rays to assess the alignment of the tibial and femoral alignment. There was a significant relation between the femoral component varus/valgus angle and three sub scores (fixed flexion contracture, maximum valgus/varus and range of movement) in Bristol Knee scores. The best functional out come correlated with femoral components of 4–8 degrees of valgus


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 543 - 543
1 Oct 2010
Akula M Dertavitian J Lyall H Roy N Sharma H Shaw C
Full Access

Introduction: Distal radius locking plates are increasingly being used to treat distal radius fractures. The purpose of our study was to determine the medium term clinical and radiological outcome of comminuted, displaced fractures of the distal radius. We present our experience in using the Aculoc (Acumed) volar fixed angle plate to treat 100 consecutive fractures of the distal radius. Methods: All one hundred patients were prospectively (clinically and radiologically) assessed between 2003 –2007, with a minimum follow up of one year. Fractures were radiologically classified using the Frykman classification Clinical outcome was measured using the Mayo score, DASH questionnaire, SF36 and Range of Wrist Movement and pinch and grasp power. The post operative x rays were assessed for fracture union, alignment and displacement. Conclusion: Our study demonstrates that volar fixation of distal radius fractures, using a fixed angle, locking accumed plate provides satisfactory treatment for fractures of the distal radius. Angular stability of the implant provides mechanical stability and aids early rehabilitation which results in good functional outcomes


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 321 - 321
1 May 2006
Andrews S Bentall S Atkinson D
Full Access

To measure for evidence of early subsidence of Accolade tapered uncemented femoral stems. To quantify any subsidence and to identify factors which may predispose to this. A retrospective audit of patients who have received Accolade stem total hip joint replacement in Hawkes Bay Hospital from October 2003 to October 2004. Post operative and follow up x rays (within one year of surgery) were reviewed and position of femoral component in the femur was measured and adjusted for magnification and angulation. Thirty-eight patients were identified. Patients age averaged 66 years old (44 – 82yo). Results show an mean subsidence of 2.8mm with a range of 0 – 13mm. There is evidence of early subsidence of Accolade femoral stems. In cases of large subsidence under sizing of the femoral component was identified as the most significant contributing factor


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 319 - 319
1 Nov 2002
Sudhahar TA Glasgow MMS Donnell ST
Full Access

This is a prospective study analysing the accuracy of expected tunnel position (graft site) for anterior cruciate ligament reconstruction and to decide whether or not confirmation of the tunnel site using intraoperative imaging is required. 35 cases of anterior cruciate ligament reconstruction using bone patella bone tendon performed by three surgeons are studied. The surgeons use three different techniques. Immediately after the surgery, the surgeon marks the expected tunnel site (graft site) in a diagram (AP and LAT of femur and tibia) without seeing the x rays and a separate observer studies the actual position in the x-ray. Significance of the difference is studied using statistical tests. Best surgical outcome can be obtained using radiological confirmation of tunnel position intraoperatively with the guide wires


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 29 - 29
1 Apr 2012
Gardner A Spilsbury J Marks D Thompson A Miller P Tatman A
Full Access

Reviewing our experience of scoliosis in children with a Cavopulmonary Shunt or Fontan circulation and the cardiovascular challenges that this presents. A notes and x ray review was performed. Special attention was paid to the changes in cardiovascular status whilst prone. The review was from first presentation to latest follow up. There were 6 patients who underwent 7 major procedures between 2001 and 2009. All had cardiac procedures in early life. Both definitive fusion and growing instrumentation was used. All procedures were successful. Growing instrumentation allowed earlier primary surgery before completion of the Fontan circulation. All have been subsequently lengthened in a lateral position. The mean follow up is 56 months. There was one death 40 months following last surgery, cause unrelated to spinal surgery. In the older patients with a completed Fontan significant blood loss was seen, due to the raised venous pressure required to run the Fontan, and occult hypotension seen as a climbing difference between Pulmonary Artery Wedge Pressure and Central Venous Pressure were common when prone. We recommend early intervention, using instrumentation without fusion to correct the deformity over time and allow intervention prior to completing the Fontan circulation. As haemodynamic instability increases with increasing time in the prone position, surgery should be expedited rapidly


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 7 - 7
1 Sep 2014
Ajai A
Full Access

The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results. Methods. 45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish comminution. The external oblique view for subtalar joint was performed with the patient supine, the knee at about 60 degree of flexion and the limb rotated externally 45 degree with a vertical X ray beam. All of these patients were managed by an external fixator using the principle of ligamentotaxis. Patients were evaluated by AOFAS. Results. We identified two broad patterns of secondary lines on plain X-rays:. with anterior secondary fracture lines and. with posterior secondary fracture lines. There were 20 cases of tongue type and 25 of joint depression type fracture pattern by the Essex-Lopresti classification. Forty two (93.4%) patients had fractures with posterior secondary fracture line and 3 (6.7%) patients had anterior secondary lines. The calcaneo-cuboid type of anterior secondary line pattern was present in 2 (4.5%) cases, and the plantar type in only 1 (2.5%) case. We observed posterior secondary line Type A pattern in 2 (4.5%) cases, depression / central depression type B in 20 (44.5%) cases, tongue shaped Type C pattern in 16 (36.5%) cases and Type D severely comminuted fracture line pattern in 4 (8.7%) cases. Conclusion. Comminution was significantly associated with prognosis and final outcome. Evaluation of secondary fracture lines corresponds with comminution of fractures of the calcaneus and the final outcome of these fractures. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 105 - 105
1 Feb 2012
Martiana K
Full Access

A retrospective descriptive preliminary study on early experience using all pedicle screw correction. Pedicle screw fixation enables enhanced correction of spinal deformities. However, the technique is still in early development in our clinic. Tends of the scoliosis patient to come in late ages make maximum correction failed. A total 16 patients are subjected to pedicle screw fixation for spinal deformities were analyzed descriptively as an early follow-up in the last two-year. 14 patients are girl and 2 are boys. The age range between 12 to 18 year. 8 are Kings type II and 8 are Kings type III, 212 screws were inserted between Th3 – L2 (14-18 screws per-patient), all concave pedicles were inserted with screws but in convex side every two or three pedicles were inserted. The position of screws was analyzed using the post-operative plain X ray film. Before surgery the mean deformity measurement are 52.56° (range, 42-72°, correction achieved was 18° (range 10-34%, it was correlated to 68% achievement (range, 53-80%). All patients are happy with their image improvement. In total 212 screws inserted, 28 screws are malpositions (13.2%), but no clinical complication recorded. In this early experience using all pedicle screw scoliosis surgery, all patients are happy with the results although the correction only 53-80(. More patients are needed to improve this achievement


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 206 - 206
1 Jul 2014
Senthilkumar V Goel S Gupta K
Full Access

Introduction. Stem cells have the capacity for self renewal and capability of differentiation into various cell lineages. Non union remains a clinically important problem in orthopaedic surgery. Method. We randomly assigned 45 patients into 3 groups. Test group: 15 patients in which mesenchymal stem cells prepared by conventional density-gradient centrifugation using ficoll-hypaque solution were injected (n=15), control A: 15 patients in which autogenous bone marrow aspirate were injected (n=15), control B: 15 patients in which neither the stem cell nor bone marrow injection given, symptomatically treated(n=15). Ultra sound and x rays were performed at follow up of 6, 12, 18, 24 weeks and comparison done. Results. Stem cell group: 12 patients out of 13 followed showed excellent results and 1 patient showed good result. Control A bone marrow injection group: 6/15 patients showed excellent results and 3 patients showed good results. Control B: only 2/15 patients showed excellent results. In fracture gap 4–5mm the stem cell group showed union in most of the patients. In control A and control B patients with same fracture gap failed to unite. Conclusion. In fracture situations, in which a manipulation or augmentation of natural healing mechanisms is needed to regenerate larger quantities of new bone Stem cells play a part. This technique of percutaneous stem cell injection provides a very safe, easy, non immunogenic, non invasive and reliable alternative to open bone grafting. This one-stage isolation procedure in comparison to the ex-vivo expansion of autologous cells from bone marrow/embryonic cells reduces the cost and infection rates related to the extra personal need and extended time required for the expansion. Summary. Stem cells have potential to enhance bone healing in non union of fractures