Introduction: In this study we have studied the range of motion within Dynesys treated discs and levels adjacent to flexible stabilisation. Dynesys was designed to offer physiological motion at the lumbar spine. An advantage which is superior to abolishing movements through spinal fusion. Methods: A cohort of 75 post-Dynesys patients had weight-bearing lateral lumbar spine
There is still want of evidence in the current literature of any significant improvement in clinical outcome when comparing computer-assisted total knee arthroplasty (CA-TKA) with conventional implantation. Analysis of alignment and of component orientation have shown both significant and non-significant differences between the two methods. Not much work has been reported on clinical evidence of stability of the joint. We compared computer-assisted and conventional surgery for TKA at 5.4 years follow-up for patients with varus osteoarthritic knees with deformity of more than 15∗. Our goal was to assess clinical outcome, stability and restoration of normal limb alignment. We used CT and Cine video
Introduction: Occult fractures of carpal bones are underestimed. To be treated succesfully fractures of the scaphoid must be identified at an early stage. A delay in detection may result in non union. We validated with 3 prospective studies a new tool using scintigraphy : The quantitative Xray bone scan (QRS). Material and Methods: A previous preliminary prospective study with 60 patients was performed and published to valid the QRS as a step in diagnosis of wrist occult bones fractures equal to RMI. This exam is a bone scan with 2 improvments. 1) A quantification of the fixation spot : If the spot is two times more important on the injuried wrist (than controlateral side) the fracture is sure. 2) If you combine plain Xrays of the the wrist with scintigraphy the fracture is automatically located. This previous report pointed that repeat set of scaphoid views, dynamic and static, Ct scan, proved unsuitable for screening occult fractures of the wrist. Result: Between november 97 and march 04, 667 patients were enrolled in a prospective continue study. 40% (260/667) of patients with an injury of the wrist with normal
Using digital X-rays to plan a hip replacement can cause problems with sizing and templating the prosthesis. Using an AP view of both hips is desirable as this allows the use of the sometimes unaffected contralateral hip for templating. We devised a method of using a 20mm ball bearing as a marker positioned at the same depth as the greater trochanter, but between the patient's legs. Placing the marker between the patient's legs avoids the problem of the marker disappearing off the side of the X-ray, as is seen when placing the marker at the side of the obese patient. The marker is then used to calibrate the size of the digital X-ray. We used a hundred consecutive post-operative X-rays, comparing the size of the head of the femoral prosthesis used at surgery with the size measured pre-operatively using the marker.Background
Method
To evaluate Radiological changes in the lumbosacral spine after insertion of Wallis Ligament for Foraminal Stenosis. Thirty two Levels in Twenty Six patients were followed up with standardised radiographs after insertion of Wallis Ligaments for Foraminal Stenosis. Wallis ligaments as a top-off or those with prolapsed discs were not included. The Radiological parameters compared were Anterior and Posterior Disc height, Foraminal height and width, The inter-vertebral angle (IVA), Lumbar lordosis and Scoliosis if any. The presence of slips and their progression post-op was noted, as was bony lysis if any. There were ten males with thirteen levels and sixteen females with nineteen levels in the study. Eighteen levels (56.25%) were L4/L5, ten (31.25%) were L5/S1 and 4 (12.5%)were L3/L4. The average age in the series was 59.6 years (Range 37 – 89 yrs). Average follow up was 9.5 months (Range 2 to 36). The Average increase in Anterior disc height was 1.89 mm (+/−1.39), the posterior disc height increased by an average 1.09 mm (+/−1.14). Foraminal height increased by an average 3.85 mm (+/− 2.72), while foraminal width increased by 2.14 mm (+/− 1.38). The IVA increased in 16 and reduced in 15 patients, with no change in 1. Lumbar Lordosis increased in 23 patients, with an average value of 2.3°. No patient exhibited progression in scoliosis and no lysis could be identified. There were three Grade I slips pre-op; none progressed.Purpose
Methods and Results
To evaluate Radiological changes in the lumbosacral spine after insertion of Wallis Ligament for Foraminal Stenosis. Thirty two Levels in Twenty Six patients were followed up with standardised radiographs after insertion of Wallis Ligaments for Foraminal Stenosis. Wallis ligaments as a top-off or those with prolapsed discs were not included. The Radiological parameters compared were Anterior and Posterior Disc height, Foraminal height and width, The inter-vertebral angle (IVA), Lumbar lordosis and Scoliosis if any. The presence of slips and their progression post-op was noted, as was bony lysis if any. There were ten males with thirteen levels and sixteen females with nineteen levels in the study. Eighteen levels (56.25%) were L4/L5, ten (31.25%) were L5/S1 and 4 (12.5%)were L3/L4. The average age in the series was 59.6 years (Range 37 – 89 yrs). Average follow up was 9.5 months (Range 2 to 36). The Average increase in Anterior disc height was 1.89 mm (+/−1.39), the posterior disc height increased by an average 1.09 mm (+/−1.14). Foraminal height increased by an average 3.85 mm (+/− 2.72), while foraminal width increased by 2.14 mm (+/− 1.38). The IVA increased in 16 and reduced in 15 patients, with no change in 1. Lumbar Lordosis increased in 23 patients, with an average value of 2.3°. No patient exhibited progression in scoliosis and no lysis could be identified. There were three Grade I slips pre-op; none progressed. Foraminal dimensions and Disc height were consistently improved after Wallis insertion. Changes in IVA and Lumbar lordosis were however variable. A longer follow up is suggested to look for sustained improvement and the presence of lysis.
Our aim was to evaluate the indications for patients undergoing magnetic resonance imaging (MRI) of the knee prior to referral to an orthopaedic specialist, and ascertain whether these scans altered initial management. We retrospectively reviewed all referrals received by a single specialist knee surgeon over a 1-year period. Patient demographics, relevant history, examination findings and past surgical procedures were documented. Patients having undergone MRI prior to referral were identified and indications for the scans recorded. These were reviewed against The NHS guidelines for Primary Care Physicians to identify if the imaging performed was appropriate in each case.Aims and objectives
Materials and Method
Neck of femur fractures are a common presentation and certain patients can be managed with a total hip replacement. To receive a total hip replacement the pelvic X-rays should be templated as per AO guidelines and a common way this is performed is by including a calibration marker on the X-ray. The aim of this study is to assess and improve upon the use of the calibration marker. Details of patients admitted with a neck of femur fracture from January 1st 2018 until December 31st 2018 were gathered and used to review each initial X-ray and determine if a calibration marker was included. 376 patients were admitted with a neck of femur fracture over the one year period. 36% of patients did not have a calibration marker on their initial pelvic X-ray and 11% did not have a chest X ray. 215 patients had an intracapsular fracture and 39 went on to have a total hip replacement. 12 patients were lacking a calibration marker on their original
Aims: Irradiated allograft bone may help to reduce the risk of transmission of infectious agents from donor to recipient. The purpose of this study was to establish the results of impaction bone grafting of acetabular defects with froze, irradiated allograft bone. Methods: All patients treated by a single surgeon with impaction bone grafting of acetabular defects at revision total hip replacement were reviewed retrospectively. All operations were performed during the period 1994–2000. The mean follow-up was 50 months (range 30–96 months). Case notes and
The aim is to investigate if there is a relation between patellar height and knee flexion angle. For this purpose we retrospectively evaluated the radiographs of 500 knees presented for a variety of reasons. We measure knee flexion angle using a computer-generated goniometer. Patellar height was determined using computer generated measurement for the selected ratios, namely, the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. A search of an NHS hospital database was made to identify the knee
Background. An improved understanding of intervertebral disc (IVD) structure and function is required for treatment development. Loading induces micro-fractures at the interface between the nucleus pulposus (NP) and the annulus fibrosus (AF), which is hypothesized to induce a cascade of cellular changes leading to degeneration. However, there is limited understanding of the structural relationship between the NP and AF at this interface and particularly response to load. Here, X-ray scattering is utilised to provide hierarchical morphometric information of collagen structure across the IVD, especially the interface region under load. Methodology. IVDs were imaged using the I22 SAXS/WAXS beamline at Diamond Light Source. Peaks associated with the D-banded structure of collagen fibrils were fitted to quantify their azimuthal distribution, as well the magnitude and direction of internal strains under static and applied strain (0–20%). Results. IVD tissue regions exhibited structural “AF-like” and “NP-like” fingerprints. Demonstrating high internal strains on collagen fibres particularly within the NP region of the disc. AF and NP regions showed distinct collagen orientation and internal strains with an apparent lack of bracing structure seen at the interface between the differential mechanical tissues. X-ray scattering under tensile strain provided structural information at high resolution, with clear differences observed between normal and degenerate discs under load. Conclusion.
Aim: Assessing Polyethylene wear is very important in following up patients after Total hip replacement (THR) and Livermore method (using callipers) is routinely used by clinicians in calculating this wear. Our aim was to assess if ‘Imagika’, a new computer software programme can accurately assess polyethylene wear(PE-wear). We also compared the computer software with the Livermore method in calculating wear. Method: We used 15 different THR
Introduction: A good cup positioning requires reliable anatomical landmarks expecially for navigation. The anterior pelvic plane (APP) seems to be a good reference for navigation because it is in relation with pelvic tilt which do affect the position of the cotyle and consequently the position of the cup. The value of this plane is not well known according to gender, age, weight… The aim of the study is to assess radiologically the APP in standing and supine position before and after total hip arthroplasty. MATERIALS AND Methods: 92 Patients (32 males, 60 females, mean age 65 years) underwent strict lateral X-rays in standing and supine standardized position. Uninterpretable or unsatisfying
Patients with osteoarthritis of the knee reviewed by the General practioners, are usually referred for further management to the orthopaedic surgeon. It was our observation that patients were usually referred with supine knee X-rays. This meant weight-bearing films were repeated at the clinic. Methods: We sent out questionnaires to GPs inquiring whether they asked for X-rays of the knee prior to patient referral and whether they asked for weight bearing films. We also reviewed the policy in one National Hospital Service trust and one teaching hospital with regards to GPs asking for weight bearing films. The time patients spent waiting at the X-rays department was noted. Finally we inquired about the cost of a knee X-ray. Results: A total number of 65 questionnaires were sent and the response was 44 i.e. 67%. 80% of the GPs asked for non weight bearing X-rays prior to referral. Only 5% asked for weight bearing films. The radiology departments of hospitals in one NHS trust and the teaching hospital did not accept weight bearing requests from GPs. The time taken for a patient to get an
The best follow up strategy after hip replacement (THR) is unclear. There are conflicting demands to obtain early diagnosis of loosening, and to minimise clinic visits. It would be desirable to achieve follow up with a validated symptom questionnaire alone, but it is unclear how frequently THRs are asymptomatic during early loosening. This study examined the relationship between patient reported symptoms after THR using two measures (Oxford Hip Questionnaire (OHQ) and Visual Analogue Scale (VAS)), and the classification of the patients AP
Introduction. Magnetic resonance arthrogram (MRA) is the investigation of choice in young adults with symptoms of femero acetabular impingement. The aim of the study is to assess the accuracy of MRA when correlated with surgical findings on hip arthroscopy. Materials and Method. Between June 2007 and January 2014, 136 patients had MRA followed by subsequent arthroscopy at our institution. The radiology information system was used to gather MRA data. All scans were reported by a consultant radiologist with a specialist interest in musculoskeletal radiology. Patient records were reviewed to gather surgical data. Assessment was made of labral injury, Camshaft (CAM) or Pincer lesion and degeneration of the cartilage. Results. Mean age at MRA was 34.5 years with a 2.5:1 female to male ratio. For labral pathology sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89, 100, 100 and 22% respectively. For CAM (62, 80, 79 and 64% respectively) and Pincer lesions (15, 84, 81 and 18% respectively). MRA was specific for picking up Grade 3/4 degenerate changes in the articular cartilage (92.2%) but was not as sensitive (60%), PPV 55 and NPV 94. Conclusion. These findings demonstrate that MRA is a sensitive and specific imaging modality for assessing the labrum and articular surface, but not as good for assessing CAM and Pincer lesions. This could be due to the static nature of the MRA or a lack of firm definition as to what constitutes a CAM or Pincer lesion leading to under reporting. This maybe better assessed with plane
Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg
Introduction. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one such important factor to achieve satisfactory flexion. Aim. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria:. Patients who had previous bony surgery on lower end femur. Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by a Physiotherapist with the help of a Goniometer. Results. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral
Aims: Functional results of anterior cruciate ligament (ACL) is closely related to the anatomical position of the graft. Femoral or tibial miss placements are associated with increase laxity, decrease range of motion. Based on anatomical dissections we developed a triangle method able to be used as fluoroscopic intra-operative landmark to increase the reproductibility of the placements. Methods: A lateral
The authors report their preliminary experience with a minimum of one year follow –up of hydroxyapatite coating as the means of fixation of the femoral head in hip resurfacing. Between Dec 2003 and Dec 2004, of the 23 cases performed by the senior author,22 were available for follow up,15 were women (68.2%) and 7 were men (31.8). The femoral and acetabular components of the uncemented version of the CORMET 2000(Corin,Cire ncester,UK) were used. The surgical approach was the Hardinge approach in all cases. Patients were assessed pre-operatively for pain and function,using the Harris Hip Score. Post operatively they were assessed in clinic with
Introduction: Acute elbow trauma is commonly seen in the emergency department. The purpose of the present study was to evaluate in our emergency department the assessment of elbow trauma radiographs in children. Methods: 136 patients aged between 0 and 16 presented at our institution for an elbow trauma over a 6 months period. All the radiographs were digitalised and stored in a commercially available computerised
Aims:ACL revision surgery is a second-generation type of knee ligament surgery. The artificial ligaments, the imperfect mastering of arthoscopic assisted surgery and the absence of clinical and radiological analysis of peripheral laxities are among the main factors for failures. Methods:43 patients of a mean age of 29y were previously operated between 1 and 5 times.14 artificial ligaments, 23 patellar tendons and 4 hamstrings tendons failed as a first ACL reconstruction. The mean time between the first operation and the index revision was 44 months. In 6 cases an additional HTO was used. Different tendon grafts were used: quadriceps 11, patellar 19 and hamstrings 8. In 3 occasions an additional extra articular reefing was used. The patients were reviewed by one independent observer using KT 1000, Stress
Background: Over many years our understanding of fracture patterns and management has evolved. One of the biggest steps was the adoption of the principles of fracture fixation as described by the Arbitsgemeinschaft fur Osteosynthesefragen (AO). The application of this philosophy has allowed us to optimise fracture management and improve outcome. In our unit we noted a number of complications resulting from suboptimal fracture fixations of ankles some of which required revision. It was decided to review fracture fixation of ankles in the unit to see whether the basic principles of fixation was being followed in our DGH. Aim: To evaluate whether the AO principles of fixation for ankle fractures are being followed in our local unit. Patients and Methods: 52 consecutive patients over a period of 1 year from August 2005 to August 2006 with bi malleolar and isolated medial malleolar ankle fractures, requiring surgery, had their case notes and pre operative
Objective: We report an unusual presentation of telangiectatic osteosarcoma of distal femur in a preadolescent boy. Methods: A 9 year old boy fell down heavily while he was on holiday and fractured his distal femur. He was given above knee plaster locally and then transferred him to hospital where he lives normally. He developed increasing pain over next two weeks over fracture site (4 weeks after injury) and was reviewed in clinic.
Introduction: The development of laboratory techniques in the last ten years has enabled the successful harvest, in vitro selection, culture and transplant of chondrocytes. The study proposes that transplantation of autologous chondrocytes prevents degeneration of the intervertebral disc following outer annular injury in an ovine model. Methods: Eight sheep were anaesthetised and five contiguous lumbar discs were exposed via a left-sided posterolateral approach. Four of the animals were given full thickness annular incisions in three alternate discs. No annular incisions were made in the other 4 sheep. Costal cartilage was harvested from the left twelfth rib of all animals. Tissue was cultured and the chondrocytes were labelled in vitro with CFSE for verification following transplantation. Six weeks later autologous cultured chondrocytes were injected into the lower two alternate discs of all animals, leaving the uppermost discs and those untouched in between as internal controls. Animals were sacrificed after three, six, twelve and twenty-four weeks. Results were based on
Introduction:. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one of the important factors to achieve satisfactory flexion. Aim:. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods:. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria:
. 1). Patients who had previous bony surgery on lower end femur. 2). Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by an independent Physiotherapist with the help of a Goniometer. Results:. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral
Introduction: Preoperative use of tomodensitometry is a common practice when assessing fractures with intraarticular involvement, helping to determine the most appropriate surgical approach according to the lesions observed. To date, during the surgical procedure itself, radiographical or fluoroscopic controls still largely rely on two dimensions
Introduction: As the age for performing a primary knee replacement is gradually falling there is increase need and demand for revision total knee replacement and subsequent revisions thereafter. There are very few published studies showing the outcome of re revision knee replacement surgery. Aim: We aim to show functional outcome of 21 patients at 3 to 5 years after undergoing Re revision knee arthroplasty. Methods: We defined re revision as a procedure where there was exchange of either one or both Tibial and Femoral components using a modular revision system. We included all patients undergoing re revision knee replacement and had complete records &
Objectives/Background: Long-term outcome in THR is multifactorial influenced. Malpositioning leads to complications as early loosening, leg length difference or dislocation of the artificial joint. A proven factor for early losening is a misplacment of the center of rotation or varusposition of the stem. A higher luxation risk results out of high inclination and anteversion angles an reduced soft tissue tension. Aim of this study was to prove the image free navigation software in the modular Navitrack-System to check the implant position based on anatomical intraoperative acquired data. Design/Methods: In 35 consecutive cases we implantet the ACA screwcup and the Optan anatomical stem with use of the Navitrack navigation System. The software calculates al relevant data out of intraopertive probed landmarks. Intraoperative the shifting of the center of rotation, the cup anteversion and inclination, the stem inclination and torsion and the leglength shift is shown in real time. Intraoperative data were compared with postoperative position measurement in plain X-rays and in 15 patients in postoperative CT scans. Results: In all cases navigated implantpositioning was possible. In 3 cases stem positioning was not possible cause of refference loosening. Mean inclination of the cup as shown in the Navigation System was 52 (range 45 – 58 ), mean anteversion was 11 (range -5 – 27). Mean postoperative inclination measured on postoperative X-Ray was 53,8 (range 49 – 60). The difference between the shown values from the CAS System to the postoperative
Introduction: An accepted treatment of lateral compartment osteoarthritis with valgus deformity is to correct the malalignment, and unload the affected compartment. Previous techniques have used large fixation plates to secure complete osteotomy sites. We present a prospective study using a novel incomplete opening wedge osteotomy, in treating lateral compartment osteoarthritis in active patients younger than 65. Methods: We assessed all patients (n=26) who underwent opening wedge femoral osteotomy with Puddu plate fixation over a 5 – year period by one surgeon (PRA). All patients had long leg
This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy
Atrophic non-unions are usually attributed to impaired blood supply but the events that lead to atrophic non-union remain poorly understood. Recent studies. 1,. 2. have shown that vascularity is not reduced in established non-unions but these studies have not examined vascularity at an early stage. The aims of this study were to: 1) develop and validate a clinically relevant small animal model of atrophic non-union and 2) test the hypothesis that the vessel density of atrophic non-unions reaches that of normal healing bones but at a later time point. Twenty eight adult female Wistar rats underwent application of a novel circular frame external fixator to the right tibia under general anaesthesia. The fixator construct was standardised, with eight needles that were drilled through the skin into the proximal and distal metaphyses of the tibia. An osteotomy was performed with a 1mm burr under irrigation. The periosteum was removed on 14 of the 28 animals using a scalpel and the intramedullary canal was curetted. Both insults were performed proximally and distally for a distance equivalent to 1 diameter of the tibia. A 1mm gap was introduced at the osteotomy site and the wound was closed. Once the animal had recovered it was allowed unrestricted weight bearing. Anteroposterior
Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this prospective study was to report the survivorship and the clinical and radiographic outcomes and the metal ions dosage of a group of patients operated with metal on PCU arthroplasty featuring large metal diameter heads, at 5 years from surgery. Study Design & Methods. 68 consecutive patients treated with the THS were included. The patients have been contacted by phone call and invited to return to our centre for clinical (Oxford Hip Score, OHS, and Harris Hip Score, HHS), radiographic exam and metal ion levels evaluation. All the patients were operated with uncemented stems. Results. The survival rate is 100% and no major complications were seen. The average preoperative OHS was 17 (6–34), at follow-up it was 44 (40–48). The average preoperative HHS was 48 (12–76), at follow-up it was 93 (84–100). On the
Stems are a crucial part of implant stabilization in revision total knee arthroplasty. In most cases the metaphyseal bone is deficient, and stabilization in the diaphyseal cortical bone is necessary to keep the implant tightly fixed to bone and to prevent tilt and micromotion. While sleeves and cones can be effective in revision total joint arthroplasty, they are technically difficult and may lead to major bone loss in cases of loosening or infection, especially if the stem is cemented past the cone. A much more conservative method is to ream the diaphysis to the least depth possible to achieve tight circumferential fixation, and to apply porous augments to the undersurface of the tibial tray or inner surface of the femoral component to allow them to bottom out against the bone surface and apply compressive load. If a robust, strong taper, stem and component combination is used, rim contact on only one side is necessary to achieve rigid permanent fixation. Porous and non-porous stems are available. The non-porous stems should have a spline surface that engages the diaphyseal bone and achieves rigid initial fixation but does not provide long-term axillary support. In that way the porous rim-engaging surface can bear compressive load and finally unload the stem and taper junction. Correctly designed stems do not stress relieve unless they are porous-coated. In situations where metaphyseal bone is not available, porous-coated stems that link to hinge prostheses are a very important part of the armamentarium in complex revision arthroplasty. Use of stems requires experience and special technique. Slight underreaming and initial scratch fit are necessary techniques. This does not result in tight fixation every time because split of the cortex does occasionally occur. In most cases these splits do not need to be repaired, but when there is a question, an intra-operative
Introduction. Literature describes pelvic rotation on lateral
Introduction. Ankle fractures are common injuries presenting to trauma departments and ankle open reduction and internal fixation (ORIF) is one of the first procedures targeted in early orthopaedic training. Failure to address the fracture pattern with the appropriate surgical technique and hardware may lead to early failure resulting in revision procedures or premature degenerative change. Patients undergoing revision ORIF are known to be at much greater risk of complications, and many of these secondary procedures may be preventable. Method. A retrospective analysis of all patients attending our unit for ankle ORIF over a two year period was undertaken. Patients were identified from our Bluespier database and a review of
Amniotic membrane (AM) and amnion/chorion foetal membranes (ACM) are mainly composed of collagen & laminin layers and constitute relatively new materials to the dental market. They have proven effective for periodontal treatments such as Guided Tissue Regeneration (GTR) [1–3]. Based on our expertise in the field of lyophilisation & securisation of human bone allograft (Phoenix® process), we aimed to develop our own process applied to ACM and to control its in vivoefficacy in GTR indication. Human placentas were donated under informed consent. ACM were separated from placenta and processed with a proprietary AMTRIX (TBF) Process. Resulting product was called ACMTRIX. The effectiveness of ACMTRIX in GTR was evaluated using an in vivorat calvaria defect model as followed:. Empty defect (2 animals),. ACMTRIX apposed onto the defect (4 animals),. 3 Bone substitutes (allogenic – mineralized cortical bone powder (Phoenix®); demineralized cancellous bone powder mixed with hydroxyapatite and demineralized bone matrix (DBM) cancellous block) filled in the defect and covered by ACMTRIX (4 animals). One animal per study group was sacrificed after 8 weeks, all others after 8 weeks. Evaluations were performed by: macroscopic observations,
In early secondary arthritis due to femoral dysplasia, varus osteotomy achieves a control of arthritis for two decades in 80 % of cases : it is therefore a very reliable conservative treatment. Moreover, in carefully selected cases of severe arthritis in young active patients, a valgus osteotomy can achieve pain relief for a decade in 70 % of cases. THE VARUS OSTEOTOMY is recommended when the arthritis is due to a coxa valga ≥ 140°. By reducing the inclination angle to 125° the abductors level of arm is optimized, and their contracture is decreased. Therefore, the osteotomy reduces the surface strains, but it does not improve the extent of articular surfaces. A – . INDICATIONS. 1) Four factors are mandatory to achieve long term improvement:. The arthritis must be the . consequence. of the dysplasia, with degenerative changes localized at the supero lateral part of the head and of the acetabulum. This can be confirmed by isotope scanning. If the arthritic changes are not localised the desease is rather a primary arthritis, or an inflammatory or a metabolic disease, which are not an indication for a biomecanical treatment. There must be a real . coxa valga. , evidenced by coxometry. Anteversion is mesured by CT scan, and the inclinaison is mesured on a
We have implanted 371 CLS acetabular components in our centre since 1989. Despite design changes in the component we report 4 cases of failure by fracture through the metal backing of the cup. Our aim is to highlight this uncommon mechanism of failure and advise that in cases of unexplained hip pain in those with CLS acetabular components
A series of 76 distal tibial pilon fractures treated with surgical fixation were retrospectively reviewed from case notes, plain radiographs and CT imaging. Patient demographics, injury and fracture patterns, methods and timing of fixation and clinical and radiological outcomes were assessed over a mean follow up period of 8.6 months (range 2–30). Definitive fixation was most commonly performed through an open technique (71 cases) with plate fixation. CT imaging was used to plan the most direct approach to access the fracture fragments. Single or double incision techniques were used to access the tibia, with fixation of the fibular performed when necessary. Superficial infection occurred in 5 cases (6.9%) and deep infection in 2 (2.8%). Aseptic wound breakdown occurred in 5 cases (6.9%). The rate of wound breakdown after three-incision technique was 37.5%. There were 10 cases of non-union (13.9%) and 8 of mal-union (10.5%). Post-traumatic arthritis was present on the most recent
Introduction. Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for TAD within 20 mm. However the definition of neck axis and the limb position of lateral radiograph are not clearly described in the original literature. We propose the refined TAD by defining these factors. The objective of this study was to analyze the interobserver agreement of this refined TAD. Materials and Method.
We reviewed 35 patients who underwent a medial unicondylar knee replacement, with an average follow up of 4 years (for functional assessment). All patents had a weight bearing AP and lateral
Introduction: Distal radius locking plates are increasingly being used to treat distal radius fractures. The purpose of our study was to determine the medium term clinical and radiological outcome of comminuted, displaced fractures of the distal radius. We present our experience in using the Aculoc (Acumed) volar fixed angle plate to treat 100 consecutive fractures of the distal radius. Methods: All one hundred patients were prospectively (clinically and radiologically) assessed between 2003 –2007, with a minimum follow up of one year. Fractures were radiologically classified using the Frykman classification Clinical outcome was measured using the Mayo score, DASH questionnaire, SF36 and Range of Wrist Movement and pinch and grasp power. The post operative
To measure for evidence of early subsidence of Accolade tapered uncemented femoral stems. To quantify any subsidence and to identify factors which may predispose to this. A retrospective audit of patients who have received Accolade stem total hip joint replacement in Hawkes Bay Hospital from October 2003 to October 2004. Post operative and follow up
This is a prospective study analysing the accuracy of expected tunnel position (graft site) for anterior cruciate ligament reconstruction and to decide whether or not confirmation of the tunnel site using intraoperative imaging is required. 35 cases of anterior cruciate ligament reconstruction using bone patella bone tendon performed by three surgeons are studied. The surgeons use three different techniques. Immediately after the surgery, the surgeon marks the expected tunnel site (graft site) in a diagram (AP and LAT of femur and tibia) without seeing the
Reviewing our experience of scoliosis in children with a Cavopulmonary Shunt or Fontan circulation and the cardiovascular challenges that this presents. A notes and
The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results. Methods. 45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish comminution. The external oblique view for subtalar joint was performed with the patient supine, the knee at about 60 degree of flexion and the limb rotated externally 45 degree with a vertical
A retrospective descriptive preliminary study on early experience using all pedicle screw correction. Pedicle screw fixation enables enhanced correction of spinal deformities. However, the technique is still in early development in our clinic. Tends of the scoliosis patient to come in late ages make maximum correction failed. A total 16 patients are subjected to pedicle screw fixation for spinal deformities were analyzed descriptively as an early follow-up in the last two-year. 14 patients are girl and 2 are boys. The age range between 12 to 18 year. 8 are Kings type II and 8 are Kings type III, 212 screws were inserted between Th3 – L2 (14-18 screws per-patient), all concave pedicles were inserted with screws but in convex side every two or three pedicles were inserted. The position of screws was analyzed using the post-operative plain
Introduction. Stem cells have the capacity for self renewal and capability of differentiation into various cell lineages. Non union remains a clinically important problem in orthopaedic surgery. Method. We randomly assigned 45 patients into 3 groups. Test group: 15 patients in which mesenchymal stem cells prepared by conventional density-gradient centrifugation using ficoll-hypaque solution were injected (n=15), control A: 15 patients in which autogenous bone marrow aspirate were injected (n=15), control B: 15 patients in which neither the stem cell nor bone marrow injection given, symptomatically treated(n=15). Ultra sound and