Objectives. Local corticosteroid infiltration is a common practice of treatment for lateral epicondylitis. In recent studies no statistically significant or clinically relevant results in favour of corticosteroid injections were found. The injection of autologous blood has been reported to be effective for both intermediate and long-term outcomes. It is hypothesised that blood contains growth factors, which induce the healing cascade. Methods. A total of 60 patients were included in this prospective randomised study: 30 patients received 2 ml autologous blood drawn from contralateral upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received 2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral epicondyle. Outcome was measured using a pain score and Nirschl staging of lateral epicondylitis. Follow-up was continued for total of six months, with assessment at one week, four weeks, 12 weeks and six months. Results. The corticosteroid injection group showed a statistically significant decrease in pain compared with autologous blood injection group in both visual analogue scale (VAS) and Nirschl stage at one week (both p < 0.001) and at four weeks (p = 0.002 and p = 0.018, respectively). At the 12-week and six-month follow-up, autologous blood injection group showed statistically significant decrease in pain compared with corticosteroid injection group (12 weeks: VAS p = 0.013 and Nirschl stage p = 0.018; six months: VAS p = 0.006 and Nirschl p = 0.006). At the six-month final follow-up, a total of 14 patients (47%) in the corticosteroid injection group and 27 patients (90%) in autologous blood injection group were completely relieved of pain. Conclusions. Autologous blood injection is efficient compared with corticosteroid injection, with less side-effects and minimum recurrence rate


Bone & Joint Open
Vol. 5, Issue 9 | Pages 729 - 735
3 Sep 2024
Charalambous CP Hirst JT Kwaees T Lane S Taylor C Solanki N Maley A Taylor R Howell L Nyangoma S Martin FL Khan M Choudhry MN Shetty V Malik RA

Aims. Steroid injections are used for subacromial pain syndrome and can be administered via the anterolateral or posterior approach to the subacromial space. It is not currently known which approach is superior in terms of improving clinical symptoms and function. This is the protocol for a randomized controlled trial (RCT) to compare the clinical effectiveness of a steroid injection given via the anterolateral or the posterior approach to the subacromial space. Methods. The Subacromial Approach Injection Trial (SAInT) study is a single-centre, parallel, two-arm RCT. Participants will be allocated on a 1:1 basis to a subacromial steroid injection via either the anterolateral or the posterior approach to the subacromial space. Participants in both trial arms will then receive physiotherapy as standard of care for subacromial pain syndrome. The primary analysis will compare the change in Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include the change in OSS at six and 12 months, as well as the Pain Numeric Rating Scale (0 = no pain, 10 = worst pain), Disabilities of Arm, Shoulder and Hand questionnaire (DASH), and 36-Item Short-Form Health Survey (SF-36) (RAND) at three months, six months, and one year after injection. Assessment of pain experienced during the injection will also be determined. A minimum of 86 patients will be recruited to obtain an 80% power to detect a minimally important difference of six points on the OSS change between the groups at three months after injection. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after a subacromial space steroid injection between the anterolateral versus posterior approach in patients with subacromial pain syndrome. This will help to guide treatment for patients with subacromial pain syndrome. Cite this article: Bone Jt Open 2024;5(9):729–735


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims. Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB. Methods. The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after GHJ injection or SSNB in patients with frozen shoulder. This will help provide effective treatment to patients with frozen shoulder. Cite this article: Bone Jt Open 2023;4(3):205–209


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


Bone & Joint Open
Vol. 1, Issue 9 | Pages 605 - 611
28 Sep 2020
McKean D Chung SL Fairhead R Bannister O Magliano M Papanikitas J Wong N Hughes R

Aims. To describe the incidence of adverse clinical outcomes related to COVID-19 infection following corticosteroid injections (CSI) during the COVID-19 pandemic. To describe the incidence of positive SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) testing, positive SARS-COV2 IgG antibody testing or positive imaging findings following CSI at our institution during the COVID-19 pandemic. Methods. A retrospective observational study was undertaken of consecutive patients who had CSI in our local hospitals between 1 February and 30June 2020. Electronic patient medical records (EPR) and radiology information system (RIS) database were reviewed. SARS-CoV-2 RT-PCR testing, SARS-COV2 IgG antibody testing, radiological investigations, patient management, and clinical outcomes were recorded. Lung findings were categorized according to the British Society of Thoracic Imaging (BSTI) guidelines. Reference was made to the incidence of lab-confirmed COVID-19 cases in our region. Results. Overall, 1,656 lab-confirmed COVID-19 cases were identified in our upper tier local authority (UTLA), a rate of 306.6 per 100,000, as of 30June 2020. A total of 504 CSI injections were performed on 443 patients between 1 February and 30June 2020. A total of 11 RT-PCR tests were performed on nine patients (2% of those who had CSI), all of which were negative for SARS-CoV-2 RNA, and five patients (1.1%) received an SARS-CoV-2 IgG antibody test, of which 2 (0.5%) were positive consistent with prior COVID-19 infection, however both patients were asymptomatic. Seven patients (1.6%) had radiological investigations for respiratory symptoms. One patient with indeterminate ground glass change was identified. Conclusion. The incidence of positive COVID-19 infection following corticosteroid injections was very low in our cohort and no adverse clinical outcomes related to COVID-19 infection following CSI were identified. Our findings are consistent with CSI likely being low risk during the COVID-19 pandemic. The results of this small observational study are supportive of the current multi-society guidelines regarding the judicious use of CSI. Cite this article: Bone Joint Open 2020;1-9:605–611


Bone & Joint Open
Vol. 5, Issue 7 | Pages 534 - 542
1 Jul 2024
Woods A Howard A Peckham N Rombach I Saleh A Achten J Appelbe D Thamattore P Gwilym SE

Aims. The primary aim of this study was to assess the feasibility of recruiting and retaining patients to a patient-blinded randomized controlled trial comparing corticosteroid injection (CSI) to autologous protein solution (APS) injection for the treatment of subacromial shoulder pain in a community care setting. The study focused on recruitment rates and retention of participants throughout, and collected data on the interventions’ safety and efficacy. Methods. Participants were recruited from two community musculoskeletal treatment centres in the UK. Patients were eligible if aged 18 years or older, and had a clinical diagnosis of subacromial impingement syndrome which the treating clinician thought was suitable for treatment with a subacromial injection. Consenting patients were randomly allocated 1:1 to a patient-blinded subacromial injection of CSI (standard care) or APS. The primary outcome measures of this study relate to rates of recruitment, retention, and compliance with intervention and follow-up to determine feasibility. Secondary outcome measures relate to the safety and efficacy of the interventions. Results. A total of 53 patients were deemed eligible, and 50 patients (94%) recruited between April 2022 and October 2022. Overall, 49 patients (98%) complied with treatment. Outcome data were collected in 100% of participants at three months and 94% at six months. There were no significant adverse events. Both groups demonstrated improvement in patient-reported outcome measures over the six-month period. Conclusion. Our study shows that it is feasible to recruit to a patient-blinded randomized controlled trial comparing APS and CSI for subacromial pain in terms of clinical outcomes and health-resource use in the UK. Safety and efficacy data are presented. Cite this article: Bone Jt Open 2024;5(7):534–542


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 498 - 503
1 Apr 2016
Mahadevan D Attwal M Bhatt R Bhatia M

Aims. The objective of this double-blind randomised controlled trial was to assess whether ultrasound guidance improved the efficacy of corticosteroid injections for Morton’s neuroma (MN). . Patients and Methods. In all, 50 feet (40 patients) were recruited for this study but five feet were excluded due to the patients declining further participation. The mean age of the remaining 36 patients (45 feet) was 57.8 years (standard deviation (. sd. ) 12.9) with a female preponderance (33F:12M). All patients were followed-up for 12 months. Treatment was randomised to an ultrasound guided (Group A) or non-ultrasound guided (Group B) injection of 40 mg triamcinolone acetonide and 2 ml 1% lignocaine, following ultrasound confirmation of the diagnosis. . Results. The mean visual analogue score for pain improved significantly in both groups (Group A – from 64 mm, . sd. 25 mm to 29 mm, . sd. 27; Group B – from 69 mm, . sd. 23 mm to 37 mm, . sd. 25) with no statistical difference between them at all time-points. The failure rate within 12 months of treatment was 11/23 (48%) and 12/22 (55%) in Groups A and B, respectively (p = 0.458). The improvement in Manchester Oxford Foot Questionnaire Index and patient satisfaction favoured Group A in the short-term (three months) that almost reached statistical significance (p = 0.059 and 0.066 respectively). However, this difference was not observed beyond three months. . Conclusion. This study has shown that ultrasound guidance did not demonstrably improve the efficacy of corticosteroid injections in patients with MN. Take home message: In the presence of a clear diagnosis of MN, a trained clinician who understands the forefoot anatomy may perform an injection without ultrasound guidance with good and safe results. Cite this article: Bone Joint J 2016;98-B:498–503


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1246 - 1252
1 Sep 2012
Penning LIF de Bie RA Walenkamp GHIM

A total of 159 patients (84 women and 75 men, mean age of 53 (20 to 87)) with subacromial impingement were randomised to treatment with subacromial injections using lidocaine with one of hyaluronic acid (51 patients), corticosteroid (53 patients) or placebo (55 patients). Patients were followed up for 26 weeks. The primary outcome was pain on a visual analogue score (VAS), and secondary outcomes included the Constant Murley score, shoulder pain score, functional mobility score, shoulder disability questionnaire and pain-specific disability score. The different outcome measures showed similar results. After three, six and 12 weeks corticosteroid injections were superior to hyaluronic acid injections and only at six weeks significantly better than placebo injections. The mean short-term reduction in pain on the VAS score at 12 weeks was 7% (. sd. 2.7; 97.5% confidence interval (CI) 0.207 to 1.55; p = 0.084) in the hyaluronic acid group, 28% (. sd. 2.8; 97.5% CI 1.86 to 3.65; p < 0.001) in the corticosteroid group and 23% (. sd. 3.23; 97.5% CI 1.25 to 3.26; p < 0.001) in the placebo group. At 26 weeks there was a reduction in pain in 63% (32 of 51) of patients in the hyaluronic acid group, 72% (38 of 53) of those in the corticosteroid group and 69% (38 of 55) of those in the placebo group. We were not able to show a convincing benefit from hyaluronic acid injections compared with corticosteroid or placebo injections. Corticosteroid injections produced a significant reduction in pain in the short term (three to 12 weeks), but in the long term the placebo injection produced the best results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 105 - 105
4 Apr 2023
Kale S Mehra S Bhor P Gunjotikar A Dhar S Singh S
Full Access

Total Knee Arthroplasty (TKA) improves the quality of life of osteoarthritic and rheumatoid arthritis patients, however, is associated with moderate to severe postoperative pain. There are multiple methods of managing postoperative pain that include epidural anesthesia but it prevents early mobilization and results in postoperative hypotension and spinal infection. Controlling local pain pathways through intra-articular administration of analgesics is a novel method and is inexpensive and simple. Hence, we assess the effects of postoperative epidural bupivacaine injection along with intra-articular injection in total knee replacement patients. The methodology included 100 patients undergoing TKA randomly divided into two groups, one administered with only epidural bupivacaine injection and the other with intra-articular cocktail injection. The results were measured based on a 10-point pain assessment scale, knee's range of motion (ROM), and Lysholm knee score. The VAS score was lower in the intra-articular cocktail group compared to the bupivacaine injection group until the end of 1-week post-administration (p<0.01). Among inter-group comparisons, we observed that the range of motion was significantly more in cocktail injection as compared to the bupivacaine group till the end of one week (p<0.05). Lysholm's score was significantly more in cocktail injection as compared to the bupivacaine group till the end of one week (p<0.05). Our study showed that both epidural bupivacaine injection and intra-articular injection were effective in reducing pain after TKA and have a comparable functional outcome at the end of 4 weeks follow up. However, the pain relief was faster in cases with intra-articular injection, providing the opportunity for early rehabilitation. Thus, we recommend the use of intra-articular cocktail injection for postoperative management of pain after total knee arthroplasty, which enables early rehabilitation and faster functional recovery of these patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 93 - 93
10 Feb 2023
Wang A Hughes J Fitzpatrick J Breidhahl W Ebert J Zheng M
Full Access

Interstitial supraspinatus tears can cause persistent subacromial impingement symptoms despite non operative treatment. Autologous tendon cell injection (ATI) is a non-surgical treatment for tendinopathies and tear. We report a randomised controlled study of ATI compared to corticosteroid injection (CS) as treatment for interstitial supraspinatus tears and tendinopathy. Inclusion criteria were patients with symptom duration > 6 months, MRI confirmed intrasubstance supraspinatus tear, and prior treatment with physiotherapy and ≥ one CS or PRP injection. Participants were randomised to receive ATI to the interstitial tear or corticosteroid injection to the subacromial bursa in a 2:1 ratio, under ultrasound guidance. Assessments of pain (VAS) and function (ASES) were performed at baseline, and 1, 3, 6 and 12 months post treatment. 30 participants (19 randomised to ATI) with a mean age of 50.5 years (10 females) and a mean duration of symptoms of 23.5 months. Baseline VAS pain and ASES scores were comparable between groups. While mean VAS pain scores improved in both groups at 3 months after treatment, pain scores were superior with ATI at 6 months (p=0.01). Mean ASES scores in the ATI group were superior to the CS group at 3 months (p=0.026) and 6 months (p=0.012). Seven participants in the CS group withdrew prior to 12 months due to lack of improvement. At 12 months, mean VAS pain in the ATI group was 1.6 ± 1.3. The improvements in mean ASES scores in the ATI group at 6 and 12 months were greater than the MCID (12.0 points). At 12 months, 95% of ATI participants had an ASES score > the PASS (patient acceptable symptom state). This is the first level one study using ATI to treat interstitial supraspinatus tear. ATI results in a significant reduction in pain and improvement in shoulder function


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 532 - 539
1 Jun 2024
Lei T Wang Y Li M Hua L

Aims. Intra-articular (IA) injection may be used when treating hip osteoarthritis (OA). Common injections include steroids, hyaluronic acid (HA), local anaesthetic, and platelet-rich plasma (PRP). Network meta-analysis allows for comparisons between two or more treatment groups and uses direct and indirect comparisons between interventions. This network meta-analysis aims to compare the efficacy of various IA injections used in the management of hip OA with a follow-up of up to six months. Methods. This systematic review and network meta-analysis used a Bayesian random-effects model to evaluate the direct and indirect comparisons among all treatment options. PubMed, Web of Science, Clinicaltrial.gov, EMBASE, MEDLINE, and the Cochrane Library were searched from inception to February 2023. Randomized controlled trials (RCTs) which evaluate the efficacy of HA, PRP, local anaesthetic, steroid, steroid+anaesthetic, HA+PRP, and physiological saline injection as a placebo, for patients with hip OA were included. Results. In this meta-analysis of 16 RCTs with a total of 1,735 participants, steroid injection was found to be significantly more effective than placebo injection on reported pain at three months, but no significant difference was observed at six months. Furthermore, steroid injection was considerably more effective than placebo injection for functional outcomes at three months, while the combination of HA+PRP injection was substantially more effective at six months. Conclusion. Evidence suggests that steroid injection is more effective than saline injection for the treatment of hip joint pain, and restoration of functional outcomes. Cite this article: Bone Joint J 2024;106-B(6):532–539


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1142 - 1147
3 Oct 2022
van den Berg C van der Zwaard B Halperin J van der Heijden B

Aims. The aim of this retrospective study was to evaluate the rate of conversion to surgical release after a steroid injection in patients with a trigger finger, and to analyze which patient- and trigger finger-related factors affect the outcome of an injection. Methods. The medical records of 500 patients (754 fingers) treated for one or more trigger fingers with a steroid injection or with surgical release, between 1 January 2016 and 1 April 2020 with a follow-up of 12 months, were analyzed. Conversion to surgical release was recorded as an unsuccessful treatment after an injection. The effect of patient- and trigger finger-related characteristics on the outcome of an injection was assessed using stepwise manual backward multivariate logistic regression analysis. Results. Treatment with an injection was unsuccessful in 230 fingers (37.9%). Female sex (odds ratio (OR) 1.87 (95% confidence interval (CI) 1.21 to 2.88)), Quinnell stage IV (OR 16.01 (95% CI 1.66 to 154.0)), heavy physical work (OR 1.60 (95% CI 0.96 to 2.67)), a third steroid injection (OR 2.02 (95% CI 1.06 to 3.88)), and having carpal tunnel syndrome (OR 1.59 (95% CI 0.98 to 2.59)) were associated with a higher risk of conversion to surgical release. In contrast, an older age (OR 0.98 (95% CI 0.96 to 0.99)), smoking (OR 0.39 (95% CI 0.24 to 0.64)), and polypharmacy (OR 0.39, CI 0.12 to 1.12) were associated with a lower risk of conversion. The regression model predicted 15.6% of the variance found for the outcome of the injection treatment (R. 2. > 0.25). Conclusion. Factors associated with a worse outcome following a steroid injection were identified and should be considered when choosing the treatment of a trigger finger. In women with a trigger finger, the choice of treatment should take into account whether there are also one or more patient- or trigger-related factors that increase the risk of conversion to surgery. Cite this article: Bone Joint J 2022;104-B(10):1142–1147


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 620 - 626
1 May 2022
Stadecker M Gu A Ramamurti P Fassihi SC Wei C Agarwal AR Bovonratwet P Srikumaran U

Aims. Corticosteroid injections are often used to manage glenohumeral arthritis in patients who may be candidates for future total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (rTSA). In the conservative management of these patients, corticosteroid injections are often provided for symptomatic relief. The purpose of this study was to determine if the timing of corticosteroid injections prior to TSA or rTSA is associated with changes in rates of revision and periprosthetic joint infection (PJI) following these procedures. Methods. Data were collected from a national insurance database from January 2006 to December 2017. Patients who underwent shoulder corticosteroid injection within one year prior to ipsilateral TSA or rTSA were identified and stratified into the following cohorts: < three months, three to six months, six to nine months, and nine to 12 months from time of corticosteroid injection to TSA or rTSA. A control cohort with no corticosteroid injection within one year prior to TSA or rTSA was used for comparison. Univariate and multivariate analyses were conducted to determine the association between specific time intervals and outcomes. Results. In total, 4,252 patients were included in this study. Among those, 1,632 patients (38.4%) received corticosteroid injection(s) within one year prior to TSA or rTSA and 2,620 patients (61.6%) did not. On multivariate analysis, patients who received corticosteroid injection < three months prior to TSA or rTSA were at significantly increased risk for revision (odds ratio (OR) 2.61 (95% confidence interval (CI) 1.77 to 3.28); p < 0.001) when compared with the control cohort. However, there was no significant increase in revision risk for all other timing interval cohorts. Notably, Charlson Comorbidity Index ≥ 3 was a significant independent risk factor for all-cause revision (OR 4.00 (95% CI 1.40 to 8.92); p = 0.036). Conclusion. There is a time-dependent relationship between the preoperative timing of corticosteroid injection and the incidence of all-cause revision surgery following TSA or rTSA. This analysis suggests that an interval of at least three months should be maintained between corticosteroid injection and TSA or rTSA to minimize risks of subsequent revision surgery. Cite this article: Bone Joint J 2022;104-B(5):620–626


Bone & Joint Open
Vol. 1, Issue 11 | Pages 709 - 714
5 Nov 2020
Finsen V Kalstad AM Knobloch RG

Aims. We aimed to establish the short- and long-term efficacy of corticosteroid injection for coccydynia, and to determine if betamethasone or triamcinolone has the best effect. Methods. During 2009 to 2016, we treated 277 patients with chronic coccydynia with either one 6 mg betamethasone or one 20 mg triamcinolone cortisone injection. A susequent injection was given to 62 (26%) of the patients. All were reviewed three to four months after injection, and 241 replied to a questionnaire a mean of 36 months (12 to 88) after the last injection. No pain at the early review was considered early success. When the patient had not been subsequently operated on, and indicated on the questionnaire that they were either well or much better, it was considered a long-term success. Results. At the three- to four-month review, 22 (9%) reported that they had no pain. The long-term success of one injection was 15% and rose to 29% after a second injection. Logistic regression tests showed that both early success (odds ratio (OR) 5.5, 95% confidence interval (CI) 2.1 to 14.4; p = 0.001) and late success (OR 3.7, 95% CI 1.7 to 8.3; p = 0.001) was greater with triamcinolone than with betamethasone. Late success was greater for patients with symptoms for less than 12 months (OR 3.0, 95% CI 1.4 to 6.7; p = 0.006). We saw no complications of the injections. Conclusion. We conclude that the effect of corticosteroid injection for coccygodynia is moderate, possibly because we used modest doses of the drugs. Even so, they seem worthwhile as they are easily and quickly performed, and complications are rare. If the choice is between injections of betamethasone or triamcinolone, the latter should be selected. Cite this article: Bone Joint Open 2020;1-11:709–714


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 74 - 74
1 Feb 2017
Klingenstein G Jain R Porat M Reid J Schoifet S
Full Access

Introduction. Liposomal bupivacaine has been shown to be effective in managing post-operative pain in hallux valgus and hemorrhoid surgery. However, non-industry-supported and well-powered randomized studies evaluating its efficacy in Total Knee Arthroplasty (TKA) are lacking. Our hypothesis was that liposomal bupivacaine would not decrease post-operative visual analog pain scores (VAS) or narcotic consumption in the acute post-operative period. Methodology. Two hundred seven consecutive patients were enrolled into a single-blinded prospective randomized study. We included patients undergoing unilateral TKA by five fellowship-trained surgeons with a diagnosis of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis. Patients were excluded for any other diagnosis necessitating TKA, allergy to the medications, or pre-operative opiate use. Participants received standardized pain management, anesthesia, and physical therapy. Patients were randomized intra-operatively to one of three groups: an intra-articular (IA) injection of bupivacaine and morphine at the conclusion of the procedure, a peri-articular (PA) injection of a bupivacaine and morphine, or a PA injection of liposomal bupivacaine. Post-operative pain VAS and mean morphine equivalents (MME) consumed were recorded and compared utilizing analysis of variance (ANOVA). A power analysis demonstrated that 159 patients were needed for 80% power to detect a 25% difference in VAS or MME. Results. Patients in each study group had a mean VAS score of 3.95 (SD 2.1), 3.97 (SD 1.9). and 3.86 (SD 1.8) (p=0.94), respectively. MME consumed per day in each group was 100.7 (SD 48.4), 100.1 (SD 42.2), and 98.9 (SD 41.6) (p=0.97). Conclusion. Liposomal bupivacaine does not alter mean pain scores or post-operative narcotic consumption in patients undergoing unilateral TKA. Further, no difference was noted in comparing patients who received a single IA injection versus a PA injection. To our knowledge, this is the first reported study to evaluate post-operative pain control between identical IA and PA injections in patients undergoing unilateral TKA


Aims. There is conflicting evidence on the safety of intra-articular injections of hyaluronic acid (HA) or corticosteroids (CSs) before total knee arthroplasty (TKA). We performed a meta-analysis of the relationship between intra-articular injections and subsequent infection rates after TKA. Methods. We searched PubMed, EMBASE, and the Cochrane Library for cohort studies that assessed the effect of preoperative injection of drugs into the joint cavity on the infection rate after TKA. The outcomes analyzed included the total infection rate, as well as those for different preoperative injection time periods and different drugs. Results. Eight studies, including 73,880 in the injection group and 126,187 in the control group, met the inclusion criteria. The injection group had a significantly higher postoperative infection rate than the control group (risk ratio (RR) 1.16; 95% confidence interval (CI) 1.07 to 1.27; p < 0.001; I. 2. = 32%). For patients who received injections up to three months preoperatively, the postoperative infection risk was significantly higher than that in the control group (RR 1.26; 95% CI 1.18 to 1.35; p<0.001; I. 2. = 0%). There was no significant difference in the infection rates between the four-to-six-month injection and control groups (RR 1.12; 95% CI 0.93 to 1.35; p = 0.240; I. 2. = 75%) or between the seven-to-12-month injection and control groups (RR 1.02; 95% CI 0.94 to 1.12; p = 0.600; I. 2. = 0%). Conclusion. Current evidence suggests that intra-articular injections of CSs or HA before TKA increase the risk of postoperative infection. Injections administered more than three months before TKA do not significantly increase the risk of infection. Cite this article: Bone Joint Res 2022;11(3):171–179


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 586 - 592
1 May 2020
Wijn SRW Rovers MM van Tienen TG Hannink G

Aims. Recent studies have suggested that corticosteroid injections into the knee may harm the joint resulting in cartilage loss and possibly accelerating the progression of osteoarthritis (OA). The aim of this study was to assess whether patients with, or at risk of developing, symptomatic osteoarthritis of the knee who receive intra-articular corticosteroid injections have an increased risk of requiring arthroplasty. Methods. We used data from the Osteoarthritis Initiative (OAI), a multicentre observational cohort study that followed 4,796 patients with, or at risk of developing, osteoarthritis of the knee on an annual basis with follow-up available up to nine years. Increased risk for symptomatic OA was defined as frequent knee symptoms (pain, aching, or stiffness) without radiological evidence of OA and two or more risk factors, while OA was defined by the presence of both femoral osteophytes and frequent symptoms in one or both knees. Missing data were imputed with multiple imputations using chained equations. Time-dependent propensity score matching was performed to match patients at the time of receving their first injection with controls. The effect of corticosteroid injections on the rate of subsequent (total and partial) knee arthroplasty was estimated using Cox proportional-hazards survival analyses. Results. After removing patients lost to follow-up, 3,822 patients remained in the study. A total of 249 (31.3%) of the 796 patients who received corticosteroid injections, and 152 (5.0%) of the 3,026 who did not, had knee arthroplasty. In the matched cohort, Cox proportional-hazards regression resulted in a hazard ratio of 1.57 (95% confidence interval (CI) 1.37 to 1.81; p < 0.001) and each injection increased the absolute risk of arthroplasty by 9.4% at nine years’ follow-up compared with those who did not receive injections. Conclusion. Corticosteroid injections seem to be associated with an increased risk of knee arthroplasty in patients with, or at risk of developing, symptomatic OA of the knee. These findings suggest that a conservative approach regarding the treatment of these patients with corticosteroid injections should be recommended. Cite this article: Bone Joint J 2020;102-B(5):586–592


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 19 - 19
17 Apr 2023
Niessen L Wendlandt R Schulz A
Full Access

A promising application of Mesenchymal stem cells (MSCs) is the treatment of non-unions. Substituting bone grafts, MSCs are directly injected into the fracture gap. High cell viability seems to be a prerequisite for therapeutic success. Administration of the MSCs via injection creates shear stresses possibly damaging or destroying the cells. Aim of this study was to investigate the effect of the injection process on cell viability. MSCs were isolated and cultivated from femoral tissue of five subjects undergoing arthroplasty. Prior to injection, the cells were identified as MSCs. After dissolving to a concentration of 1 Million cells/ml, 1 ml of the suspension was injected through a cannula of 200 mm length and 2 mm diameter (14 G) with flow rates of 38 and 100 ml/min. The viability of the MSCs at different flow rates was evaluated by staining to detect the healthy cell fraction. It was analyzed statistically against a control group via the Kruskal-Wallis-test and for equivalence via the TOST procedure. Significance level was set to 5 %, equivalence margin to 20 %. The healthy cell fraction of the control group was 85.88 ± 2.98 %, 86.04 ± 2.53 % at 38 ml/min and 85.48 ± 1.64 % at 100 ml/min. There was no significant difference between the fraction of healthy cells (p = 0.99) for different volume flows, but a significant equivalence between the control group and the two volume flows (38 ml/min: p = 0.002, 100 ml/min: p = 0.001). When injecting MSC solutions, e.g. into a non-union, the viability of the injected cells does not deterioriate significant. The injecting technique is therefore feasible


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 120 - 120
1 Nov 2021
Gregori P Singh A Harper T Franceschi F Blaber O Horneff JG
Full Access

Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the joint space, or on the periprosthetic anatomic structures, is a common procedure used for symptom management. However, the efficacy and safety of this procedure has not been previously reported in shoulder literature. Materials and Methods. A retrospective chart review identified primary TSA patients who subsequently received a CSI into a replaced shoulder from 2011 – 2018 by multiple surgeons. Patients receiving an injection underwent clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to CSI. Demographic variables were recorded, and a patient satisfaction survey assessed the efficacy of the injection. Results. Of the 43 responders, 48.8% remembered the injection. The average time from index arthroplasty to injection was median 16.8 months. Overall, 61.9% reported decreased pain, 28.6% reported increased motion, and 28.6% reported long term decreased swelling. Improvement lasted greater than one month for 42.9% of patients, and overall 52.4% reported improvement (slight to great) in the shoulder following CSI. No patient developed a periprosthetic joint infection (PJI) within 2 years of injection. Conclusions. This study suggests that certain patients following TSA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out conditions unlikely to improve long term from a CSI. Given these findings, further study in a large, prospective trial is warranted to fully evaluate the benefits of CSI following TSA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 35 - 35
24 Nov 2023
Pérez-Prieto D Baums M Aquilina J Sleiman O Geropoulos G Totlis T
Full Access

Purpose. Intra-articular corticosteroid injection is widely used for symptomatic relief of knee osteoarthritis. However, if pain is not improved which consequences a total knee arthroplasty (TKA), there is a potential risk of post-operative periprosthetic joint infection (PJI). The aim of this study is to investigate whether the use of preoperative intra-articular corticosteroid injection increases the risk of PJI and to investigate a time frame in which the risk of subsequent infection is significantly increased. Methods. A systematic search was performed in PubMed (Medline), Scopus, and the Cochrane Library. Inclusion criteria were original studies investigating the rate of PJI in patients receiving pre-operative intra-articular corticosteroid injection compared to controls. Results. A total of 380 unique articles were screened. Six studies met the inclusion criteria with 255,627 patients in total. Overall, no statistical significance was observed in the intra-articular infection rate in corticosteroid compared to controls groups. However, intra-articular corticosteroid injections within 3 months prior to TKA were associated with a significantly increased risk of infection (OR: 1.52, 95% CI 1.37–1.67, p < 0.01); this was not observed in the 6-month period (OR: 1.05, 95% CI 0.80–1.39, p = 0.72). Conclusions. Performing an intra-articular corticosteroid injection within 3 months prior to TKA is associated with a significantly increased risk of PJI. The current evidence supports the safe use of intra-articular corticosteroid injection more than 6 months before TKA. However, additional studies are needed to clarify the risk of PJI after TKA implantation between 3 and 6 months after the last corticoid injection


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 463 - 463
1 Aug 2008
Younus A
Full Access

Lumbar steroid injection can be endorsed as a treatment component for lumbrosacral radicular pain syndrome resulting from disc herniation. The facet joint steroid injection seems to be beneficial for patients with chronic backache due to the facet joint arthritis and in the lumbar Spondylosis. We did a retrospective review of 31 patients whom we treated between 2004 and 2005 with follow up of 6 months to 24 months. There were 19 females and 12 males, aged between 29–81 years. Five patients had previous surgery for simple discectomy to posterior spinal fusion. Four patients had multiple disc prolapse at 3–4 levels, 2 patients had a severe lumbar spondylosis and spinal stenosis. The remaining 20 patients had a single level disc prolapse. All these patients were given caudal and facet joint blocks. The pre and post steroid injection Oswestry score was done. After steroid injection the Oswestry score improved by 30%. Majority of the patients had pain relief for 2–18 months. The pain relief was much better in the non operative group with single level disc pro-lapse and those patients with lumbar spondylosis. In patients with chronic back pain there is an inflammatory basis for pain generation. Lumbar steroid injection seems to be beneficial in patients with disc prolapse and lumbar spondylosis. In the literature various randomized trials have been done and their results are controversial. Our study showed definitive improvement in terms of pain and function of our patient


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 138 - 138
11 Apr 2023
Cheon S Suh D Moon J Park J
Full Access

Surgical debridement for medial epicondylitis (ME) is indicated for patients with refractory ME. The clinical efficacy of simple debridement has not been studied sufficiently. Moreover, authors experienced surgical outcome of ME was not as good as lateral epicondylitis. In this regard, authors have combined the atelocollagen injection in the debridement surgery of ME. The purpose of study was to compare clinical outcomes between simple debridement and debridement combined with atelocollagen injection in the ME. Twenty-five patients with refractory ME and underwent surgical debridement were included in the study. Group A (n=13) was treated with isolated debridement surgery, and group B (n=12) was treated with debridement combined with 1.0 mL of type I atelocollagen. Pain and functional improvements were assessed using visual analogue scale, Mayo Elbow Performance Score (MEPS) and quick Disabilities of the Arm, Shoulder and Hand (DASH) scale respectively before surgery, at 3, 6 months after surgery and at the final follow-up. Demographic data did not show significant difference between two groups before surgical procedures. Both groups showed improvement in pain and functional score postoperatively. However, at the 3 months after surgery, group B showed significantly better improvement as compared to group A(VAS 3.1 / 2.0, MEPS 71/82 qDASH 29/23). At the 6 months after surgery and final follow-up, both groups did not show any difference. Surgical debridement combined with atelocollagen is effective treatment option in refractory ME and showed better short-term outcomes compared to isolated surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 67 - 67
1 Jul 2020
Michalek A Nguyen D Varden L
Full Access

As the intervertebral disc is largely avascular, needle injection is the most practical method for delivery of therapeutic agents used in treatments for degenerative disc disease. Intradiscal pressure increases during injection, and insufficient recovery time prior to needle retraction may result in injectate leakage. In order to determine the maximum pressure and post-injection recovery time for a given injection volume and rate, an analytical model of intradiscal injection was developed and calibrated experimentally. A governing equation was derived defining intradiscal pressure as a function of effective permeability, initial elastic stiffness, nonlinear stiffness term, and injection rate. The equation was solved using a fourth order Runge-Kutta routine with a 0.05s time step and a ramp-dwell injection. The model was calibrated by performing controlled intradiscal injections on five bovine caudal intervertebral discs. Three had adjacent vertebrae intact, while two were separated from vertebrae and constrained between porous stainless steel platens. A syringe driven by a linear actuator was used to inject phosphate buffered saline through a 21g hypodermic needle inserted radially into the disc to a depth of one half of the disc diameter. Injection was performed at a rate of 75μL/s to a volume of 250μL followed by a 240s dwell. Fluid pressure was recorded during both the injection phase and subsequent recovery phase. For each experimental pressure vs time trace, model parameters were varied in order to obtain an optimal fit. The model was run with the average parameter values across a grid of possible injection protocols, with injection volume ranging from 30 to 300μL and injection time ranging from 0.1 to 5s. For each case, peak pressure and time required to reach a 1kPa threshold were recorded. Experimentally measured peak pressure ranged from 68 to 88kPa. Pressure at the end of the 240s dwell ranged from 49 to 69kPa. There was no apparent difference between discs with and without endplates. Leakage of fluid following needle retraction was observed in all specimens. Experimental data were well fit by the analytical model, which predicted higher peak pressure and longer recovery time with increasing volume, from approximately 1500s at 30μL to nearly 3000s at 300μL. The model was nearly insensitive to injection rate. The experimental data confirm pressurization of the disc during injection and injectate leakage resulting from insufficient recovery time. The model predicts that the time required to recover to below threshold leakage pressure is impractically long for both laboratory and clinical injection protocols. Similar behavior with and without endplates confirms that fluid flow is limited by permeability of the tissue itself, not the boundary conditions. Slow recovery is likely attributable to the fact that peak injection pressures were lower than the hydraulic swelling pressure of the nucleus pulposus, which has been reported to be approximately 140kPa. Due to the high swelling pressure of the nucleus pulposus, it is unlikely that intradiscal injection procedures can be performed without substantial injectate leakage following needle retraction


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 567 - 574
2 May 2022
Borton ZM Oakley BJ Clamp JA Birch NC Bateman AH

Aims. Cervical radiculopathy is a significant cause of pain and morbidity. For patients with severe and poorly controlled symptoms who may not be candidates for surgical management, treatment with transforaminal epidural steroid injections (CTFESI) has gained widespread acceptance. However, a paucity of high-quality evidence supporting their use balanced against perceived high risks of the procedure potentially undermines the confidence of clinicians who use the technique. We undertook a systematic review of the available literature regarding CTFESI to assess the clinical efficacy and complication rates of the procedure. Methods. OVID, MEDLINE, and Embase database searches were performed independently by two authors who subsequently completed title, abstract, and full-text screening for inclusion against set criteria. Clinical outcomes and complication data were extracted, and a narrative synthesis presented. Results. Six studies (three randomized controlled trials and three non-randomized observational studies; 443 patients) were included in the final review. The aggregate data support the efficacy of CTFESI in excess of the likely minimal clinically important difference. No major complications were described. Conclusion. There is increasing evidence supporting the efficacy of CTFESI. Concerns regarding the occurrence of catastrophic complications, widely shared in the case report and anecdotal literature, were not found when reviewing the best available evidence. However, the strength of these findings remains limited by the lack of highly powered high-level studies and the heterogeneity of the studies available. Further high-quality studies are recommended to address the issues of efficacy and safety with CTFESI. Cite this article: Bone Joint J 2022;104-B(5):567–574


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 21 - 21
1 Oct 2022
Stynes S Foster N O'Dowd J Ostelo R Konstantinou K
Full Access

Background. Guidelines recommend epidural steroid injections (ESI) for treating severe disc-related sciatica based on trial data showing modest reductions in leg pain, disability and surgery avoidance. Despite their widespread use, there is no clear evidence about which patients are more likely to benefit from ESI. The aim of this study was to generate consensus on potential predictors of outcome following ESI for disc-related sciatica to include in data collection in a future cohort study. Methods. A list of potential predictors of outcome following ESI was generated from existing literature and a consensus meeting with seven experts. Items were subsequently presented in a two-round on-line modified Delphi study to generate consensus among experts on which items are agreed as potential predictors of outcome from ESI (consensus defined as 70% agreement with ranking of remaining items). Results. An initial list of 53 items was generated and 90 experts were invited from seven countries to participate in the on-line Delphi study. Response rates were 48% (n=44) and 73% (n=33) for round 1 and 2 respectively. Twenty-eight additional items suggested by participants in round 1 were included in round 2. Of the 81 items, 14 reached consensus; across domains of medication use, previous surgery, pain intensity, psychosocial factors, imaging findings and type of injection. Highest ranked of remaining items included work-related and clinical assessment items. Conclusion. Based on expert consensus, items that can be routinely collected in clinical practice were identified as potential predictors of outcomes following ESI. These will be tested in a future multicentre cohort study. Conflicts of interest: No conflicts of interest. Sources of funding: This study is supported by Health Education England and the National Institute for Health Research (HEE/ NIHR ICA Programme Clinical Lectureship, Dr Siobhan Stynes, NIHR300441). The views expressed are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health and Social Care


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 43 - 43
1 May 2019
Lachiewicz P
Full Access

Surgeon-performed periarticular injection and anesthesiologist-performed femoral nerve or adductor canal block with local anesthetic have been used in multimodal pain management for total knee arthroplasty (TKA) patients. Anesthesiologist-performed adductor canal blocks are costly, time consuming, and may be unreliable. We investigated the feasibility of a surgeon-performed saphenous nerve (“adductor-canal”) block from within the knee joint. A retrospective analysis of 94 thigh-knee MRI studies was performed to determine the relationship between the width of the distal femur at the epicondylar axis and the proximal location of the saphenous nerve after its exit from the adductor canal and separation from the superficial femoral artery. After obtaining these data, TKA resections and trial component implantation were performed, using a medial parapatellar approach, in 11 fresh cadaveric lower extremity specimens. Using a blunt tip 1.5cm needle, we injected 10 ml each of two different colored solutions at two different intra-articular medial injection locations, and after 30 minutes, dissected the femoral and saphenous nerve and femoral artery from the hip to the knee to determine the location of the injections. Based upon the MRI analysis, the saphenous nerve was located (and had exited the adductor canal) at a mean of 1.5 times the epicondylar width in females, and mean 1.3 times the epicondylar width in males, proximal to the medial epicondyle. After placement of TKA trial components and injection, the proximal injection site solution bathed the saphenous nerve in 8 of 11 specimens. The proximal blunt needle and solution was adjacent, but did not puncture, the femoral artery and vein in only one specimen. This study suggests that a surgeon-performed injection of the saphenous nerve from within the knee is a feasible procedure. This technique may be a useful alternative to ultrasound guided block. A trial comparing surgeon and anesthesiologist-performed nerve block should be considered to determine the clinical efficacy of this procedure. Our anecdotal use of this intra-articular injection over the past year has been favorable. Newer, extended release anesthetic agents should be investigated with this technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 29 - 29
1 Dec 2022
Alolabi B Shanthanna H Czuczman M Moisiuk P O'Hare T Khan M Forero M Davis K Moro JK Foster G Thabane L
Full Access

Interscalene brachial plexus block is the standard regional analgesic technique for shoulder surgery. Given its adverse effects, alternative techniques have been explored. Reports suggest that the erector spinae plane block may potentially provide effective analgesia following shoulder surgery. However, its analgesic efficacy for shoulder surgery compared with placebo or local anaesthetic infiltration has never been established. We conducted a randomised controlled trial to compare the analgesic efficacy of pre-operative T2 erector spinae plane block with peri-articular infiltration at the end of surgery. Sixty-two patients undergoing arthroscopic shoulder repair were randomly assigned to receive active erector spinae plane block with saline peri-articular injection (n = 31) or active peri-articular injection with saline erector spinae plane block (n = 31) in a blinded double-dummy design. Primary outcome was resting pain score in recovery. Secondary outcomes included pain scores with movement; opioid use; patient satisfaction; adverse effects in hospital; and outcomes at 24 h and 1 month. There was no difference in pain scores in recovery, with a median difference (95%CI) of 0.6 (-1.9-3.1), p = 0.65. Median postoperative oral morphine equivalent utilisation was significantly higher in the erector spinae plane group (21 mg vs. 12 mg; p = 0.028). Itching was observed in 10% of patients who received erector spinae plane block and there was no difference in the incidence of significant nausea and vomiting. Patient satisfaction scores, and pain scores and opioid use at 24 h were similar. At 1 month, six (peri-articular injection) and eight (erector spinae plane block) patients reported persistent pain. Erector spinae plane block was not superior to peri-articular injection for arthroscopic shoulder surgery


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1364 - 1371
1 Oct 2018
Joswig H Neff A Ruppert C Hildebrandt G Stienen MN

Aims. The aim of this study was to determine the efficacy of repeat epidural steroid injections as a form of treatment for patients with insufficiently controlled or recurrent radicular pain due to a lumbar or cervical disc herniation. Patients and Methods. A cohort of 102 patients was prospectively followed, after an epidural steroid injection for radicular symptoms due to lumbar disc herniation, in 57 patients, and cervical disc herniation, in 45 patients. Those patients with persistent pain who requested a second injection were prospectively followed for one year. Radicular and local pain were assessed on a visual analogue scale (VAS), functional outcome with the Oswestry Disability Index (ODI) or the Neck Pain and Disability Index (NPAD), as well as health-related quality of life (HRQoL) using the 12-Item Short-Form Health Survey questionnaire (SF-12). Results. A second injection was performed in 17 patients (29.8%) with lumbar herniation and seven (15.6%) with cervical herniation at a mean of 65.3 days . (sd. 46.5) and 47 days . (sd. 37.2), respectively, after the initial injection. All but one patient, who underwent lumbar microdiscectomy, responded satisfactorily with a mean VAS for leg pain of 8.8 mm . (sd. 10.3) and a mean VAS for arm pain of 6.3 mm . (. sd. 9) one year after the second injection, respectively. Similarly, functional outcome and HRQoL were improved significantly from the baseline scores: mean ODI, 12.3 (. sd. 12.4; p < 0.001); mean NPAD, 19.3 (. sd. 24.3; p = 0.041); mean SF-12 physical component summary (PCS) in lumbar herniation, 46.8 (. sd. 7.7; p < 0.001); mean SF-12 PCS in cervical herniation, 43 (. sd. 6.8; p = 0.103). Conclusion. Repeat steroid injections are a justifiable form of treatment in symptomatic patients with lumbar or cervical disc herniation whose symptoms are not satisfactorily relieved after the first injection. Cite this article: Bone Joint J 2018;100-B:1364–71


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 518 - 518
1 Aug 2008
Barzilay Y Pollock R Friesem T Reddy G
Full Access

Purposes: To determine the effect of gravity on outcome in sacral epidurals injected in the prone compared to the lateral position in patients with unilateral back related leg pain. Methods: A randomised controlled trial with 2 arms. This pilot study was conducted to determine the standard deviation (SD) of the primary outcome measure to allow calculation of a final sample size. Forty patients who met the inclusion/exclusion criteria were randomly allocated to prone or lateral sacral epidural injection. Twenty patients were allocated to the prone and 20 to the left or right lateral position dependent on their radicular back pain. The primary outcome measure of back and leg pain severity was assessed using a visual analogue scale (VAS) (0= none, 10 = worst imaginable). The Oswestry disability index, SF-36 and straight leg raise were also measured. Outcomes were assessed at baseline and at 6 and 12 week follow-up. A repeated measures analysis using mixed model methodology was used to determine statistical significance. Results: The 2 groups were comparable in gender and age. The prone group had a mean improvement in VAS back pain score at 6 weeks follow-up of 0.5 compared to 1.6 in the lateral group. At 12 weeks follow-up there was a negative response of 0.1 compared to baseline in the prone group and 1.4 improvement in the lateral group. Repeated measures analysis showed no significant difference in back pain scores between the groups at the 5% level (F2,38 = 3.24; P = 0.0797). Similarly mean improvement in VAS leg pain scores at 6 weeks follow-up were 1.4 in the prone group and 1.7 in the lateral group. At 12 weeks follow-up the scores were 1.1 for the prone and 2.4 for the lateral group. Repeated measures analysis showed no significant difference in leg pain scores between the groups (F1,38= 0.76; P = 0.3898). A post-hoc power calculation using the sample VAS SD showed we had reached only 65% power. Conclusion: This pilot study has shown that sacral epidural injection for sciatica in the lateral position gives superior pain relief compared to the prone position but the difference is not statistically significant. More patients will now be recruited in order to minimise a type II error that may have occurred


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1297 - 1302
3 Oct 2020
Kurosaka K Tsukada S Ogawa H Nishino M Nakayama T Yoshiya S Hirasawa N

Aims. Although periarticular injection plays an important role in multimodal pain management following total hip arthroplasty (THA), there is no consensus on the optimal composition of the injection. In particular, it is not clear whether the addition of a corticosteroid improves the pain relief achieved nor whether it is associated with more complications than are observed without corticosteroid. The aim of this study was to quantify the safety and effectiveness of cortocosteroid use in periarticular injection during THA. Methods. We conducted a prospective, two-arm, parallel-group, randomized controlled trial involving patients scheduled for unilateral THA. A total of 187 patients were randomly assigned to receive periarticular injection containing either a corticosteroid (CS group) or without corticosteroid (no-CS group). Other perioperative interventions were identical for all patients. The primary outcome was postoperative pain at rest during the initial 24 hours after surgery. Pain score was recorded every three hours until 24 hours using a 100 mm visual analogue scale (VAS). The primary outcome was assessed based on the area under the curve (AUC). Results. The CS group had a significantly lower AUC postoperatively at 0 to 24 hours compared to the no-CS group (AUC of VAS score at rest 550 ± 362 vs 392 ± 320, respectively; mean difference 158 mm; 95% confidence interval (CI) 58 to 257; p = 0.0021). In point-by-point evaluation, the CS group had significantly lower VAS scores at 12, 15, 18, 21, 24, and 48 hours. There were no significant differences in complication rates, including surgical site infection, between the two groups. Conclusion. The addition of corticosteroid to periarticular injections reduces postoperative pain without increasing complication rate following THA. Cite this article: Bone Joint J 2020;102-B(10):1297–1302


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 83 - 83
1 Nov 2021
Nativel F Smith A Marquis M Renard D Gauthier O Vinatier C Rieux AD Guicheux J Visage CL
Full Access

Introduction and Objective. Osteoarthritis (OA) is the most common inflammatory and degenerative joint disease. Mesenchymal Stromal Cells (MSCs), with their chondro-protective and immune-regulatory properties, have been considered as a new approach to treat OA. Considering the risk of cell leakage outside the articular space and the poor survival rate after intra-articular (IA) injection, we hypothesized that cell encapsulation in cytoprotective hydrogels could overcome these limitations and provide cells with a suitable 3D microenvironment supporting their biological activity. We previously generated micromolded alginate particles (diameter 150 μm) and demonstrated the long-term viability of microencapsulated MSCs isolated from human adipose tissue (hASCs). Encapsulated cells maintained their in vitro ability to sense and respond to a pro-inflammatory environment (IFN-γ/TNF-α or synovial fluids from OA patients) by secreting PGE. 2. , IDO, HGF and TGF-β. In this study, we evaluated the anti-OA efficacy of these microencapsulated hASCs in a post-traumatic OA model in rabbits. Materials and Methods. OA was surgically induced by anterior cruciate ligament transection (ACLT)-mediated destabilization of the right knee in rabbits (n=24). Eight weeks after surgery, destabilized joints were injected (IA, 26G needle) with 200 μL of either PBS, blank microparticles, non-encapsulated or microencapsulated cells (5×10. 5. cells). Six weeks after injection, rabbits were euthanized and all destabilized (right) and sham-operated (left contralateral) joints were dissected and analyzed for OA severity. Tibial subchondral bone histomorphometric parameters were measured by quantitative micro-computed tomography (micro-CT). Histological sections of samples were analyzed after Safranin-O staining and quantitatively assessed according to a modified Osteoarthritis Research Society International (OARSI) scoring system. Immunohistochemical detection of NITEGE was performed to assess the extracellular matrix degradation. Results. Micro-CT analysis of destabilized joints confirmed that the rabbit ACLT significantly affected the tibial subchondral bone architecture as early as eight weeks, as revealed by significant changes of the subchondral bone parameters of operated joints compared to the sham operated joints. In particular, destabilized joints exhibited a Bone Volume/Tissue Volume ratio (BV/TV) ranging from 53.4% to 56.6%, compared to a mean BV/TV of 65.4% for sham operated joints. All destabilized joints also exhibited a significantly increased modified OARSI score, ranging from 7.4±0.4 for those injected with encapsulated cells to 8.9±0.2 for those injected with PBS, as compared to 4.8±0.4 for sham-operated joints. Of interest, we identified a slight, while not significant, reduction of the severity of OA lesions after injection of microencapsulated cells using the modified OARSI scoring. Finally, semi-quantitative analysis of NITEGE immunostaining revealed a significant increase in all destabilized joints that were injected with PBS or blank microparticles, in comparison with sham ones. On the contrary, NITEGE immunostaining in destabilized joints that were injected with non-encapsulated or encapsulated hASC revealed a significant reduced NITEGE immunostaining, indicating a decreased matrix degradation. Conclusions. Our data suggest that the microencapsulated hASCs exerted their anti-OA properties after IA injection in rabbit knees, as evidenced by the tendency toward a reduced modified OARSI score, and most importantly a significant reduction in NITEGE immunostaining associated matrix degradation. Further studies are now warranted to investigate the anti-OA efficacy of microencapsulated hASCs in the long-term


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 88 - 88
1 Jul 2020
Akhtar RR Khan J
Full Access

To compare the efficacy of local steroid injection with surgical decompression in treatment of carpal tunnel syndrome (CTS) in terms of frequency of pain. This randomized controlled study was conducted at the Department of Orthopaedics for a duration of 01 year, i.e. from 20th April 2016 to 19th April 2017. 130 patients with carpal tunnel syndrome with moderate (Grade 2) and severe (Grade 3) pain were included. Lottery method was used to allocate the patients randomly into two groups. Group A contained 65 patients who were subjected to surgical decompression and 65 patients were in Group B who were injected with local steroid injection. Complete history was obtained from all patients. All the surgical decompressions through mini incision technique and injections procedures were performed. Information were recorded in a pre designed Performa. Efficacy was observed significantly high in group B as compared to group A (87.7% vs. 72.3%, p=0.028). Carpal Tunnel syndrome symptoms were alleviated with surgical decompression as well as local steroid injection at a follow up done after 1 month. However the steroid injections seem to have greater efficacy than surgical decompression, hence we suggest it for routine treatment of all patients with CTS. For any reader queries, please contact . virgo_r24@hotmail.com


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2018
Klement MR Luzzi AJ Siddiqi A Valichka K Sharkey PF
Full Access

Introduction. Recovery after total knee arthroplasty (TKA) may take longer than patients expect. Furthermore, there are a subset of patients who still experience pain and dissatisfaction despite normal physical examination, radiographs, and laboratory analysis. Corticosteroid injection (CSI) is commonly used nonsurgical treatment for painful knee arthritis. However, the efficacy of CSI in patients with a painful TKA remains unknown. Methods. A retrospective charge review was performed to identify a cohort of patients who had a primary TKA performed between 2015 and 2016 and later received a CSI. All TKAs and CSIs were performed by a fellowship-trained arthroplasty surgeon. Patients receiving a CSI underwent a clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to injection. Patient variables were recorded and a survey assessed the efficacy of the injection. The survey response rate was 63.6%. Results. Of the 119 responders, 81.5% remembered the injection. The average time from index arthroplasty injection was 16.9 months (range 1–133) and patients received 1.3 averaged CSIs (range 1–4). Overall, 77.3% reported decreased pain, 54.6% reported increased motion, and 60.8% reported decreased swelling. The relief lasted greater than three months for 53.6% of patients, and 84.6% reported improvement (slight to great) in the knee. The rate of patient reported adverse events was 5.0% and included pruritus, pain, decreased energy, swelling, and clicking. No patients developed PJI as a result of the injection. Conclusions. The results of this survey suggest that patients with a painful and/or swollen TKA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out recognizable etiologies (i.e. infection, loosening, instability). This study certainly has its limitations but it is the only study of its kind. The authors hope that this provides impetus for further research regarding this investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1638 - 1640
1 Dec 2009
Pichler W Weinberg AM Grechenig S Tesch NP Heidari N Grechenig W

Intra-articular punctures and injections are performed routinely on patients with injuries to and chronic diseases of joints, to release an effusion or haemarthrosis, or to inject drugs. The purpose of this study was to investigate the accuracy of placement of the needle during this procedure. A total of 76 cadaver acromioclavicular joints were injected with a solution containing methyl blue and subsequently dissected to distinguish intra- from peri-articular injection. In order to assess the importance of experience in achieving accurate placement, half of the injections were performed by an inexperienced resident and half by a skilled specialist. The specialist injected a further 20 cadaver acromioclavicular joints with the aid of an image intensifier. The overall frequency of peri-articular injection was much higher than expected at 43% (33 of 76) overall, with 42% (16 of 38) by the specialist and 45% (17 of 38) by the resident. The specialist entered the joint in all 20 cases when using the image intensifier. Correct positioning of the needle in the joint should be facilitated by fluoroscopy, thereby guaranteeing an intra-articular injection


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 124 - 124
1 Jul 2014
Papalia R Vadala G Franceschi F Balzani LD Zampogna B D'Adamio S Maffulli N Denaro V
Full Access

Introduction. Ostochondral lesion of the knee is a common cause of chronic knee pain. Arthroscopic treatment with subcondral microfracture is a widespread technique leading to noticeable improvement of knee function and pain. To improve the effectiveness of this treatment options, we thought to add intra (PRF) or post-operative (PRP) growth factors. Platelet rich plasma (PRP) is obtained by centrifugation of the blood to produce a plasma with high concentration of platelets and growth factors. This latter represents a promising method to manage degenerative cartilage lesion and can be used postoperatively to improve clinical results of patients treated arthroscopically. Platelet Rich Fibrin (PRF) has been presented as a second-generation platelet concentrate, and it is used intraoperatively to cover the microfracuteres’ holes. No literature was found about using of PRF intraoperative in association with arthroscopic microfracture technique. The aim of this study is to compare clinical outcomes of the treatment of knee osteochondral lesion using arthroscopic microfracture technique alone or in association with PRF Intraoperative application using “Vivostat” system or with PRP “ReGen Lab” postoperative injection. Patients & Methods. 90 patients with clinical and radiographic evidence of osteochondral lesion of the medial or lateral compartment of the knee were enrolled. All patients received arthroscopic debridement and Microfractures and were randomised into 3 groups: 30 patients received microfractures and intraoperative PRF “Vivostat” injection(Group A), 30 patients received microfracture and 3 intra-articular injections of 5.5 mL PRP “Regen”(Group B), 30 patients received microfracture only. IKDC, KOOS and VAS score were administered to all patients before starting the treatment, at 1, 6 and 12 months from the end of the management. Results. Patients who received microfracture and PRF intraoperative application provided the best outcomes, showing a significant higher clinical scores (P<0.001) compared to the other two groups. Patients underwent PRP postoperative administration reported significant higher score than those undergoing arthroscopic microfracture alone (P<0.005), but lesser than Intraoperative PRF group at 6 months and 1 year follow up. Discussion/Conclusion. Treatment of osteochondral lesions of the knee using microfracture technique significantly improved functional and pain scores from the pre- to postoperatively time in the overall cohort. Intraoperative application of PRF shows significantly better outcome than postoperative PRP injections. However, additional treatment with intra-articular PRP injection as an adjunct to microfracture technique may offer better clinical outcomes over microfracture technique alone


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 5 - 5
23 Apr 2024
Sain B Sidharthan S Naique S
Full Access

Introduction. Treatment of non-union in open tibial fractures Gustilo-Anderson(GA)-3A/3B fractures remains a challenging problem. Most of these can be dealt using treatment methods that requires excision of the non-union followed by bone grafting, masquelet technique, or acute shortening. Circular fixators with closed distraction or bone transport also remains a useful option. However, sometimes due to patient specific factors these cannot be used. Recently antibiotic loaded bone substitutes have been increasingly used for repairing infected non-unions. They provide local antibiotic delivery, fill dead space, and act as a bone conductive implant, which is resorted at the end of a few months. We aimed to assess the outcome of percutaneous injection of bone substitute while treating non-union of complex open tibial fractures. Materials & Methods. Three cases of clinical and radiological stiff tibial non-union requiring further intervention were identified from our major trauma open fracture database. Two GA-3B cases, treated with a circular frame developed fracture-related-infection(FRI) manifesting as local cellulitis, loosened infected wires/pins with raised blood-markers, and one case of GA-3A treated with an intramedullary nail. At the time of removal of metalwork/frame, informed consent was obtained and Cerament-G. TM. (bone-substitute with gentamicin) was percutaneously injected through a small cortical window using a bone biopsy(Jamshedi needle). All patients were allowed to weight bear as tolerated in a well-fitting air-cast boot and using crutches. They were followed up at 6 weekly intervals with clinical assessment of their symptoms and radiographs. Fracture union was assessed using serial radiographs with healing defined as filling of fracture gap, bridging callus and clinical assessment including return to full painless weight bearing. Results. Follow-up at 6 months showed all fractures had healed with no defect or gaps with evidence of new trabecular bone and significant resorption of Cerament-G. TM. at final follow-up. There was no evidence of residual infection with restoration of normal limb function. Fractures with no internal fixation showed a mild deformity that had developed during the course of the healing, presumed due to mild collapse in the absence of fixation. These were less than 10 degrees in sagittal and coronal planes and were clinically felt to be insignificant by the patients. Conclusions. Cerament-G's unique combination of high dose antibiotics and hydroxy apatite matrix provided by calcium sulphate might help provide an osteoconductive environment to allow these stiff non-unions to heal. The matrix appears to provide a scaffold-like structure that allows new bone in-growth with local release of antibiotics helping reduce deep-seated infections. The final deformation at fracture site underlines the need for fixation- and it is very unlikely that this technique will work in mobile nonunions. Whilst similar fractures may heal without the use of bone substitute injections, the speed of healing in presence of significant fracture gap suggests the use of these bone substitutes did help in our cases. Further studies with a larger cohort, including RCTs, to evaluate the effectiveness of this technique compared to other methods are needed


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1027 - 1035
1 Aug 2016
Pereira LC Kerr J Jolles BM

Aims. Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Methods. Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. Results. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. Conclusions. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027–35


Bone & Joint Research
Vol. 5, Issue 6 | Pages 218 - 224
1 Jun 2016
Cheng N Guo A Cui Y

Objectives. Recent studies have shown that systemic injection of rapamycin can prevent the development of osteoarthritis (OA)-like changes in human chondrocytes and reduce the severity of experimental OA. However, the systemic injection of rapamycin leads to many side effects. The purpose of this study was to determine the effects of intra-articular injection of Torin 1, which as a specific inhibitor of mTOR which can cause induction of autophagy, is similar to rapamycin, on articular cartilage degeneration in a rabbit osteoarthritis model and to investigate the mechanism of Torin 1’s effects on experimental OA. Methods. Collagenase (type II) was injected twice into both knees of three-month-old rabbits to induce OA, combined with two intra–articular injections of Torin 1 (400 nM). Degeneration of articular cartilage was evaluated by histology using the Mankin scoring system at eight weeks after injection. Chondrocyte degeneration and autophagosomes were observed by transmission electron microscopy. Matrix metallopeptidase-13 (MMP-13) and vascular endothelial growth factor (VEGF) expression were analysed by quantitative RT-PCR (qPCR).Beclin-1 and light chain 3 (LC3) expression were examined by Western blotting. Results. Intra-articular injection of Torin 1 significantly reduced degeneration of the articular cartilage after induction of OA. Autophagosomes andBeclin-1 and LC3 expression were increased in the chondrocytes from Torin 1-treated rabbits. Torin 1 treatment also reduced MMP-13 and VEGF expression at eight weeks after collagenase injection. Conclusion. Our results demonstrate that intra-articular injection of Torin 1 reduces degeneration of articular cartilage in collagenase-induced OA, at least partially by autophagy activation, suggesting a novel therapeutic approach for preventing cartilage degeneration and treating OA. Cite this article: N-T. Cheng, A. Guo, Y-P. Cui. Intra-articular injection of Torin 1 reduces degeneration of articular cartilage in a rabbit osteoarthritis model. Bone Joint Res 2016;5:218–224. DOI: 10.1302/2046-3758.56.BJR-2015-0001


Bone & Joint Research
Vol. 4, Issue 1 | Pages 1 - 5
1 Jan 2015
Vázquez-Portalatín N Breur GJ Panitch A Goergen CJ

Objective . Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis, were used to determine if high frequency ultrasound can ensure intra-articular injections are accurately positioned in the knee joint. Methods. A high-resolution small animal ultrasound system with a 40 MHz transducer was used for image-guided injections. A total of 36 guinea pigs were anaesthetised with isoflurane and placed on a heated stage. Sterile needles were inserted directly into the knee joint medially, while the transducer was placed on the lateral surface, allowing the femur, tibia and fat pad to be visualised in the images. B-mode cine loops were acquired during 100 µl. We assessed our ability to visualise 1) important anatomical landmarks, 2) the needle and 3) anatomical changes due to the injection. . Results. From the ultrasound images, we were able to visualise clearly the movement of anatomical landmarks in 75% of the injections. The majority of these showed separation of the fat pad (67.1%), suggesting the injections were correctly delivered in the joint space. We also observed dorsal joint expansion (23%) and patellar tendon movement (10%) in a smaller subset of injections. Conclusion. The results demonstrate that this image-guided technique can be used to visualise the location of an intra-articular injection in the joints of guinea pigs. Future studies using an ultrasound-guided approach could help improve the injection accuracy in a variety of anatomical locations and animal models, in the hope of developing anti-arthritic therapies. Cite this article: Bone Joint Res 2015;4:1–5


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 55 - 55
1 Jul 2022
Mohamed MH Shetty A
Full Access

Abstract. Introduction. To compare the efficacy of adductor canal blocks (ACB) and periarticular anesthetic injections (PAI) with bupivacaine in total knee arthroplasty. Methods. 90 patients undergoing primary total knee arthroplasty under spinal anesthesia were randomized to 1 of 3 groups: ACB alone (15 mL of 0.5% bupivacaine), PAI alone (50 mL of 0.25% bupivacaine with epinephrine) and ACB + PAI. Primary outcome in this study was the visual analog scale (VAS) pain score in the immediate postoperative period. Secondary outcomes included postoperative opioid use, activity level during physiotheraphy, length of hospital stay and ROM. Results. Mean VAS pain score was significantly higher with ACB alone, compared with the score after use of ACB+PAI, on POD1 and POD3. Total opioid consumption through POD3 was significantly higher when ACB alone had been used compared with PAI alone and ACB+PAI. Opioid consumption in the ACB-alone group was significantly higher than that in the ACB + PAI group on POD2 and POD3 and significantly higher than that in the PAI alone group on POD2. There was no significant difference in opioid consumption between the patients treated with PAI alone and those who received ACB + PAI. The activity level during physiotherapy on POD0 was significantly lower after use of ACB alone than after use of PAI alone or ACB + PAI. Conclusion. Higher pain scores after total knee arthroplasty done with an ACB and without PAI, suggesting that ACB alone is inferior for perioperative pain control. There were no significant differences between ACB alone, PAI alone and ACB + PAI inparameters measured


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 54 - 54
1 May 2016
Iwakiri K Kobayashi A
Full Access

Introduction. Peri-articular local anesthetic injections reduce post-operative pain in total knee arthroplasty and assist recovery. It is inconclusive whether intra-operative injection of peri-articular morphine is locally effective. The aim of this study is whether the addition of morphine to peri-articular injections in only unilateral knee improves post-operative pain, range of motion, swelling in patients with simultaneous bilateral total knee arthroplasty. Materials and Methods. A prospective single-center double-blinded randomized controlled trial was undertaken to assess the local efficacy of adding morphine to intra-operative, peri-articular anesthesia in simultaneous bilateral total knee arthroplasty. Twenty eight patients with 56 TKAs were randomly divided into 2 groups, unilateral TKA with intraoperative peri-articular injection with adding morphine and the other side TKA without adding morphine. The morphine group received an intraoperative, peri-articular injection of local anesthetic (Ropivacaine 150mg), epinephrine (50μg), ketoprofen (25mg) and methylpredonisolone sodium (20mg) plus 0.1mg/kg of morphine. The no-morphine group received the same amount of local anesthetic, epinephrine, ketoprofen and methylpredonisolone sodium without morphine. The operating surgeon, operating staff, patients, physiotherapists, ward nursing staff and data collectors remained blinded for the duration of study. All surgeries were performed by the same operating team. A standard medial parapatellar approach was used in all operations. Post-operative analgesia was standardized to all participants with celecoxib daily for 3 weeks. Primary outcomes included visual analog pain scores (VAS), ROM and swelling of the thigh. Secondary outcomes included WOMAC and adverse outcomes. Result. There were no significant differences between two groups for pre-operative ROM, pre-operative pain VAS or the circumference of the thigh. There were no statistically significant differences in primary and secondary outcomes between two groups (Figure 1, 2, 3). Discussion. Multiple studies have demonstrated the clinical efficacy of multimodal peri-articular injection of analgesics in TKA for pain relief. However, the opioids often lead to nausea as an adverse effect, which is reported from 25% to 56%. The mechanism of pain relief by morphine is mainly the efficacy through the opioid receptor in central nerve system, and the other mechanism through local opioid receptor (μ-receptor) is rarely revealed for pain relief. Our study used morphine in unilateral TKA and no-morphine in the other side TKA and showed no significant difference in primary and secondary outcomes. These results revealed that the efficacy for pain relief in peri-articular injection without morphine is the same as that in no-morphine group. In conclusion, adding morphine in peri-articular injection could not be locally effective for pain relief


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 4 - 4
1 Oct 2022
Nagington A Foster N Snell K Konstantinou K Stynes S
Full Access

Background. Clinical guidelines recommend epidural steroid injection (ESI) as a treatment option for severe disc-related sciatica, but there is considerable uncertainty about its effectiveness. Currently, we know very little about factors that might be associated with good or poor outcomes from ESI. The aim of this systematic review was to synthesize and appraise the evidence investigating prognostic factors associated with outcomes following ESI for patients with imaging confirmed disc-related sciatica. Methods. The search strategy involved the electronic databases Medline, Embase, CINAHL Plus, PsycINFO and reference lists of eligible studies. Selected papers were quality appraised independently by two reviewers using the Quality in Prognosis Studies (QUIPS) tool. Between study heterogeneity precluded statistical pooling of results. Results. 2726 citations were identified; 11 studies were eligible. Overall study quality was low with all judged to have moderate or high risk of bias. Forty-five prognostic factors were identified but were measured inconsistently. The most commonly assessed prognostic factors were related to pain and function (n=7 studies), imaging features (n=6 studies), health and lifestyle (n=5 studies), patient demographics (n=4 studies) and clinical assessment findings (n=4 studies). No prognostic factor was found to be consistently associated with outcomes following ESI. Most studies found no association or results that conflicted with other studies. Conclusions. There is little, and low quality, evidence to guide practice in terms of factors that predict outcomes in patients following ESI for disc-related sciatica. The results can help inform some of the decisions about potential prognostic factors that should be assessed in future well-designed prospective cohort studies. Conflicts of interest: No conflicts of interest. Sources of funding: This study is supported by Health Education England and the National Institute for Health Research (HEE/ NIHR ICA Programme Clinical Lectureship, Dr Siobhan Stynes, NIHR300441). The views expressed are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health and Social Care


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 2 - 2
1 Nov 2016
Marsland D Grice J Calder J
Full Access

Introduction. Injections are used to treat a wide variety of pathologies. Our aim was to evaluate the efficacy and safety of foot and ankle injections in our clinic. Materials and methods. We performed a retrospective review of notes and a telephone questionnaire audit into the clinical outcome of all patients who underwent an injection of the foot or ankle in a year. All procedures were performed in an out-patient setting by a consultant musculoskeletal radiologist using either ultrasound or X-ray guidance, with a minimum of two year follow-up. According to the pathology treated, the type of injection included depomedrone, hyaluronic acid and high volume saline injections. Results. Overall 410/446 (92%) patients reported a significant improvement in symptoms and 227 (62%) reported complete resolution of their pain, with 127 (28%) remaining asymptomatic at two year follow-up. The mode time of recurrence of pain was three months. 59 (13%) underwent a further injection and 102 (23%) underwent operative intervention within the follow-up period. There were no reported infections. Complications occurred in two percent of patients, including steroid flare, pain and plantar plate ruptures. Conclusion. Injections are a safe and effective option for treating a variety of foot and ankle conditions and reduce the need for surgery. They are particularly effective for the treatment of ankle soft tissue impingement. They appear ineffective in providing significant improvement in pain for longer than three months in conditions such as plantar fasciitis and hallux rigidus


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 352 - 355
1 Mar 2005
Wilson-MacDonald J Burt G Griffin D Glynn C

We have assessed whether an epidural steroid injection is effective in the treatment of symptoms due to compression of a nerve root in the lumbar spine by carrying out a prospective, randomised, controlled trial in which patients received either an epidural steroid injection or an intramuscular injection of local anaesthetic and steroid. We assessed a total of 93 patients according to the Oxford pain chart and the Oswestry disability index and followed up for a minimum of two years. All the patients had been categorised as potential candidates for surgery. There was a significant reduction in pain early on in those having an epidural steroid injection but no difference in the long term between the two groups. The rate of subsequent operation in the groups was similar


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 18 - 18
1 Jun 2016
Grammatopoulos G Hodhody G Lane J Taylor A Kendrick B Glyn-Jones S
Full Access

Image-guided intra-articular hip injection of local-anaesthetic and steroid is commonly used in the management of hip pain. It can be used as a diagnostic and/or therapeutic tool and is of low cost (£75). The aim of this study was to assess how often a hip injection has a therapeutic effect. This is a retrospective, consecutive, case series of intra-articular hip injections performed in a tertiary referral hospital over a 2-year period (2013–4). Patients were identified from the radiology department's prospectively entered database. Clinical information, reason for injection and subsequent management was obtained from hospital records. All patients prospectively reported their pain levels in a numeric pain scale diary (out of 10) at various time points; pre-, immediately post-, 1st day-, 2nd day- and 2 weeks- post-injection. Only patients with complete pain scores at all time points were included (n=200, of the 250 injections performed over study period, 80%). The majority of injections were performed for osteoarthritis (OA) treatment (82%). The pain was significantly reduced from a pre-injection score of 7.5 (SD:2) to 5.0 (SD:3) immediately post-injection(p<0.001); only 24 (11%) reported any worsening of pain immediately post-injection. Pain significantly reduced further to 3.8(SD:3) at 2-weeks post-injection (p<0.001). 50% of patients had at least a 3 point drop in reported pain. No improvement was seen in 18 patients and 10 (5%) reported worse pain at 2-weeks compared to pre-injection. Of the OA cohort, 10% have required repeat injections, 45% required no further intervention and 45% underwent or are due for hip replacement. No immediate complications occurred. Intra-articular hip injection reduced pain in 86% of cases and has delayed any further surgical treatment for at least 2 years in over 50% of OA cases. It is hence a cost-effective treatment modality. Further work is necessary to describe factors predicting response


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 8 - 8
1 Jan 2019
Jalal M Simpson H Wallace R Peault B
Full Access

In atrophic non-union models, a minimally invasive technique is used to deliver stem cells into the fracture site via percutaneous injection. This technique is significantly affected by a backflow leakage and the net number of cells might be reduced. The Z-track method is a technique used in clinical practice for intramuscular injections to prevent backflow leakage. We evaluated the potential of the Z-track injection technique for preventing cell loss in non-union models by determining the behaviour of observable marker fluids. Firstly, toluene blue stain was used as an injection material to allow visual detection of its distribution. Rat's cadaver legs were used and tibias were kept unbroken to ensure intact skin and overlying soft tissue. Technique includes pulling the skin over the shin of tibia towards the ankle and injection of the dye around the mid-shaft. The needle was then partially pulled back, the skin was returned to its normal position and a complete extraction of the needle was followed. Secondly, a mixture of contrast material and toluene blue was used to allow direct visual and radiological detection of the injected material into the fracture site. Ante-grade nailing of tibia via tibial tuberosity was carried out followed by a 3 point closed fracture. Injection was performed into the fracture gap similarly to the steps above. X-rays were taken to visualise the location and distribution of the injected material. Observation revealed no blue stain could be detected over the skin, X -rays revealed that the radiopaque dye remained around the tibia with no escape of the material into the superficial layers or onto the skin surface. Therefore, the number of cells delivered and maintained at a target site could be increased by the Z-track method and therefore, the therapeutic benefit of stem cell injections could be optimised with this simple technique


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 824 - 831
1 Jul 2019
Mahmoud EE Adachi N Mawas AS Deie M Ochi M

Aim. Mesenchymal stem cells (MSCs) have several properties that may support their use as an early treatment option for osteoarthritis (OA). This study investigated the role of multiple injections of allogeneic bone marrow-derived stem cells (BMSCs) to alleviate the progression of osteoarthritic changes in the various structures of the mature rabbit knee in an anterior cruciate ligament (ACL)-deficient OA model. Materials and Methods. Two months after bilateral section of the ACL of Japanese white rabbits aged nine months or more, either phosphate buffered saline (PBS) or 1 x 10. 6. MSCs were injected into the knee joint in single or three consecutive doses. After two months, the articular cartilage and meniscus were assessed macroscopically, histologically, and immunohistochemically using collagen I and II. Results. Within the PBS injection (control group), typical progressive degenerative changes were revealed in the various knee structures. In the single MSC injection (single group), osteoarthritic changes were attenuated, but still appeared, especially in the medial compartments involving fibrillation of the articular cartilage, osteophyte formation in the medial plateau, and longitudinal tear of the meniscus. In the multiple-injections group, the smoothness and texture of the articular cartilage and meniscus were improved. Histologically, absence or reduction in matrix staining and cellularity were noticeable in the control and single-injection groups, respectively, in contrast to the multiple-injections group, which showed good intensity of matrix staining and chondrocyte distribution in the various cartilage zones. Osteoarthritis Research Society International (OARSI) scoring showed significantly better results in the multiple-injections group than in the other groups. Immunohistochemically, collagen I existed superficially in the medial femoral condyle in the single group, while collagen II was more evident in the multiple-injections group than the single-injection group. Conclusion. A single injection of MSCs was not enough to restore the condition of osteoarthritic joints. This is in contrast to multiple injections of MSCs, which had the ability to replace lost cells, as well as reducing inflammation. Cite this article: Bone Joint J 2019;101-B:824–831


Aims. The aim of this study was to compare the efficacy of a corticosteroid injection for the treatment of carpal tunnel syndrome (CTS) in patients with and without Raynaud’s phenomenon. Patients and Methods. In a prospective study, 139 patients with CTS were treated with a corticosteroid injection (10 mg triamcinolone acetonide); 34 had Raynaud’s phenomenon and 105 did not (control group). Grip strength, perception of touch with a Semmes-Weinstein monofilament and the Boston Carpal Tunnel Questionnaires (BCTQ) were assessed at baseline and at six, 12 and 24 weeks after the injection. The Cold Intolerance Severity Score (CISS) questionnaire was also assessed at baseline and 24 weeks after the injection


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 194 - 200
1 Feb 2016
Tsukada S Wakui M Hoshino A

There is conflicting evidence about the benefit of using corticosteroid in periarticular injections for pain relief after total knee arthroplasty (TKA). We carried out a double-blinded, randomised controlled trial to assess the efficacy of using corticosteroid in a periarticular injection to control pain after TKA. . A total of 77 patients, 67 women and ten men, with a mean age of 74 years (47 to 88) who were about to undergo unilateral TKA were randomly assigned to have a periarticular injection with or without corticosteroid. The primary outcome was post-operative pain at rest during the first 24 hours after surgery, measured every two hours using a visual analogue pain scale score. The cumulative pain score was quantified using the area under the curve. . The corticosteroid group had a significantly lower cumulative pain score than the no-corticosteroid group during the first 24 hours after surgery (mean area under the curve 139, 0 to 560, and 264, 0 to 1460; p = 0.024). The rate of complications, including surgical site infection, was not significantly different between the two groups up to one year post-operatively. . The addition of corticosteroid to the periarticular injection significantly decreased early post-operative pain. Further studies are needed to confirm the safety of corticosteroid in periarticular injection. Take home message: The use of corticosteroid in periarticular injection offered better pain relief during the initial 24 hours after TKA. Cite this article: Bone Joint J 2016;98-B:194–200


Bone & Joint Research
Vol. 10, Issue 10 | Pages 650 - 658
1 Oct 2021
Sanghani-Kerai A Black C Cheng SO Collins L Schneider N Blunn G Watson F Fitzpatrick N

Aims. This study investigates the effects of intra-articular injection of adipose-derived mesenchymal stem cells (AdMSCs) and platelet-rich plasma (PRP) on lameness, pain, and quality of life in osteoarthritic canine patients. Methods. With informed owner consent, adipose tissue collected from adult dogs diagnosed with degenerative joint disease was enzymatically digested and cultured to passage 1. A small portion of cells (n = 4) surplus to clinical need were characterized using flow cytometry and tri-lineage differentiation. The impact and degree of osteoarthritis (OA) was assessed using the Liverpool Osteoarthritis in Dogs (LOAD) score, Modified Canine Osteoarthritis Staging Tool (mCOAST), kinetic gait analysis, and diagnostic imaging. Overall, 28 joints (25 dogs) were injected with autologous AdMSCs and PRP. The patients were followed up at two, four, eight, 12, and 24 weeks. Data were analyzed using two related-samples Wilcoxon signed-rank or Mann-Whitney U tests with statistical significance set at p < 0.05. Results. AdMSCs demonstrated stem cell-like characteristics. LOAD scores were significantly lower at week 4 compared with preinjection (p = 0.021). The mCOAST improved significantly after three months (p = 0.001) and six months (p = 0.001). Asymmmetry indices decreased from four weeks post-injection and remained significantly lower at six months (p = 0.025). Conclusion. These improvements in quality of life, reduction in pain on examination, and improved symmetry in dogs injected with AdMSCs and PRP support the effectiveness of this combined treatment for symptom modification in canine OA for six months. Cite this article: Bone Joint Res 2021;10(10):650–658