Aims. We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency. Patients and Methods. A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection. Results. Of the 45 patients, 16 had
Aims. The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural
Abstract. BACKGROUND. Hemi-arthroplasty (HA) as a treatment for fractured neck of femur has slightly increased since 2019 and remarkably after the COVID pandemic. The main drawback of the treatment is ongoing cartilage deterioration that may require revision to THR. OBJECTIVE. This study assessed cartilage surface damage in hip HA by reproducing
Abstract. Introduction. Compared to the standard Tomofix plate, the
The Cierny and Mader classification assists with decision-making in the management of osteomyelitis by strafying the host status and the pathoanatomy of disease. However the
Introduction. The Cierny and Mader classification assists with decision-making by stratifying host status and the pathoanatomy of the disease. However, the
Aims. The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed
Applications of weightbearing computed tomography (WBCT) imaging in the foot and ankle have emerged over the past decade. However, the potential diagnostic benefits are scattered across the literature, and a concise overview is currently lacking. Therefore, we aimed to systematically review all reported diagnostic applications per
Introduction. Charcot neuroarthropathy is a debilitating condition that frequently leads to skeletal instability, and has an increased risk of ulceration leading to infection and amputation. However, surgical reconstruction may offer limb salvage and restauration of an ulcer-free, plantigrade stable foot for functional weight-bearing. We report on our case series according to a prospective protocol and analyse factors leading to a favourable outcome. Methods. We report a prospective follow-up of 62 patients undergoing Charcot reconstruction, May 2014- Jan 2022, by two surgeons. Peripheral vascular disease was routinely assessed using Duplex scan and major arterial disease was treated before reconstruction. Utilising 3D modelling, pre-operative planning and standardised osteotomies, we performed
Helical plates potentially bypass the medial neurovascular structures of the thigh. Recently, two plate designs (90°- and 180°-helix) proved similar biomechanically behaviour compared to straight plates. Aims of this study were: (1) Feasibility of MIPO-technique with 90°- and 180°-helical plates on the femur, (2) Assessment of distances to adjacent anatomical structures at risk, (3) Comparison of these distances to using medial straight plates instead, (4) Correlation of measurements performed in
Aims. Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological
Abstract. Introduction. MCL injuries often occur concurrently with ACL rupture – most noncontact ACL injuries occur in valgus and external rotation (ER) - and conservative MCL treatment leads to increased rate of ACL reconstruction failure. There has been little work developing effective MCL reconstructions. Methods. Cadaveric work measured MCL attachments by digitisation and radiographically, relating them to
Hip joint biomechanics can be altered by abnormal morphology of the acetabulum and/or femur. This may affect load distribution and contact stresses on the articular surfaces, hence, leading to damage and degradation of the tissue. Experimental hip joint simulators have been used to assess tribology of total hip replacements and recently methods further developed to assess the natural hip joint mechanics. The aim of this study was to evaluate articular surfaces of human cadaveric joints following prolonged experimental simulation under a standard gait cycle. Four cadaveric male right hips (mean age = 62 years) were dissected, the joint disarticulated and capsule removed. The acetabulum and femoral head were mounted in an
The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation. To compare the biomechanical stability of the extracortical SB repair with the
Aims. Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an
Aims. This study aimed to identify the effect of
The objective of this study is to evaluate the effectiveness and safety of percutaneous tenotomy of the iliopsoas tendon with the aid of ultrasound in cadavers. An
Introduction. Obtaining accurate
Aims. Both
Aims. Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and
Abstract. Introduction. Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI. Method. This is a retrospective study on patients undergoing HTO surgery using the Tomofix
Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid
Abstract. Introduction. Bone grafts are utilised in a range of surgical procedures, from joint replacements to treatment of bone loss resulting from cancer. Decellularised allograft bone is a regenerative, biocompatible and immunologically safe potential source of transplant bone. Objectives. To compare the structural and biomechanical parameters of decellularised and unprocessed (cellular) trabecular bone from the human femoral head (FH) and tibial plateau (TP). Methods. Bone pins were harvested from 10 FHs and 11 TPs (27, 34 respectively). Pins were decellularised (0.1% w/v sodium dodecyl sulphate) or retained as cellular controls. QA testing was carried out to assess protocol efficacy (total DNA and histological analysis). Cellular and decellularised FH (n=7) and TP (n=10) were uCT scanned. Material density (MD); apparent density (BV/TV); trabecular connectivity; trabecular number; trabecular thickness (Tb-t) and trabecular spacing were measured. Pins were then compression tested to determine ultimate compressive stress (UCS), Young's modulus and 0.2% proof stress. Results. Total DNA levels of decellularised bone were below 50 ng.mg. −1. dry weight. Cell nuclei and marrow were largely removed. No significant differences in properties were found between decellularised and cellular bone from either
Introduction. Partial knee arthroplasty (PKA) has demonstrated the potential to improve patient satisfaction over total knee arthroplasty. It is however perceived as a more challenging procedure that requires precise adaptation to the complex mechanics of the knee. A recently developed PKA system aims to address these challenges by
Prosthetic Hip dislocations remain one of the most common major complications after total hip arthroplasty procedures, which has led to much debate and refinement geared to the optimization of implant and bearing options, surgical approaches, and technique. The implementation of larger femoral heads has afforded patients a larger excursion distance and primary arc range motion before impingement, leading to lowered risk of hip dislocation. However, studies suggest that while the above remains true, the use of larger heads may contribute to increased volumetric wear, trunnion related corrosion, and an overall higher prevalence of loosening, pain, and patient dissatisfaction, which may require revision hip arthroplasty. More novel designs such as the dual mobility hip have been introduced into the United States to optimize stability and range of motion, while possibly lowering the frictional torque and modes of failure associated with larger fixed bearing articulations. Therefore, the aim of this study is to compare the effect of bearing design and
The “correct” rotational alignment and “normal” rotational alignment may not be the same position. Because of natural tibial plateau has average 3° varus but classical TKA method make tibial cut perpendicularly to tibial mechanical axis. Consequently femoral rotational compensation to 3° becomes necessary. While
High ankle sprains (HAS) cause subtle lesions in the syndesmotic ligaments of the distal tibiofibular joint (DTFJ). Current intrinsic
Several previous pathoanatomical and biomechanical studies focused primarily on the cam morphology as the primary contributor to symptoms of femoroacetabular impingement (FAI) and limited range of motion. However, there is a growing population of individuals with asymptomatic cam morphologies who show no clinical signs; thus, the cam deformity, alone, may not fully delineate an individual's symptomatology or limited motion. These studies expanded beyond the cam morphology, to determine how additional
Purpose. Addressing posterior tibial plateau fractures is increasingly recognized as an important prognostic factor for functional outcome. The treatment of posterior tibial plateau fractures is rather demanding and the implants are still standard, off-the-shelf implants. This emphasizes the need for a more thorough morphological study of the posterior tibial plateau, in order to treat these posterior fractures more adequately. We aimed to demonstrate
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and
The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (. sd. 3), and 22 mm (. sd. 3), respectively). An
This prospective study presents the ten-year (5 to 16) clinical and radiological results of 55 primary total hip replacements (THR) using a cementless modular femoral component (S-ROM). All patients had a significant
Background. Radial head arthroplasty (RHA) is a popular method of treatment for complex fractures of the radial head. The purpose of this study was to investigate patient outcomes and radiographic findings associated with a single
Background:. The term ‘resident's ridge’ originated from trans-tibial ACL reconstruction where a bony ridge on the medial surface of the lateral femoral condyle was mistakenly thought to represent the posterior articular margin of the condyle. This was then mistakenly used to position the ‘over the top’ guide resulting in graft malposition. With
Introduction. Conventional methods of aligning the acetabular component during hip arthroplasty and hip resurfacing often rely upon
Introduction. Hip simulators proved to be valuable, pre-clinical tests for assessing wear. Preferred implant positioning has been with cup mounted above head, i.e. ‘Anatomical’ (Figs. 1a-c) . 1,2. while the ‘Inverted’ test (cup below head) was typically preferred in debris studies (Figs. 1d-f). 3,4. In an
Introduction:. Conventional methods of aligning the acetabular component during hip arthroplasty and hip resurfacing often rely upon
Aims. To investigate the risk factors for progression of articular
cartilage damage after
Introduction. Recently, computer-aided orthopaedic surgery has enabled three dimensional (3D) preoperative planning, navigation systems and patient matched instrument, and they provide good clinical results in total knee arthroplasty. However, the preoperative planning methods and the criteria in total elbow arthroplasty (TEA) still have not sufficiently established due to the uncertainty of 3D
Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in
Graft-tunnel mismatch of the bone-patellar tendon-bone
(BPTB) graft is a major concern during
In vitro biomechanical tests allow obtaining important information about stresses and deformations inside the bone, and about the displacements of the prosthetic device under physiological load conditions. This information may be helpful for the development of innovative devices, for the improvement of the existing ones, and for defining optimized procedure for bone reconstruction depending on the typology of bone defects. The definition of a robust and reproducible reference frame is the first step in order to perform a consistent biomechanical test [1]. The aims of the current study was to define an
Hydroxyapatite-coated standard
Aims. Controversy about the use of an
Instability after arthroplasty of the shoulder
is difficult to correct surgically. Soft-tissue procedures and revision surgery
using unconstrained
Fibula shortening with an intact anterior tibiofibular ligament (ATFL) and medial ligament instability causes lateral translation of the talus. Our hypothesis was that the interaction of the AITFL tubercle of the fibular with the tibial incisura would propagate lateral translation due to the size differential. To assess what degree of shortening of the fibular would cause the lateral translation of the talus.Introduction
Aim
Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation as compared to straight plates. Aims:(1) to investigate the safety of applying different long plate designs (straight, 45°-, 90°-helical and ALPS) in MIPO-technique to the humerus. (2) to assess and compare their distances to adjacent anatomical structures at risk. MIPO was performed in 16 human cadaveric humeri using either a straight plate (group1), a 45°-helical (group2), a 90°-helical (group3) or an ALPS (group4). Using CT-angiography, distances between brachial arteries and plates were evaluated. Following, all specimens were dissected, and distances to the axillary, radial and musculocutaneous nerve were evaluated. None of the specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mm(range)) between each plate and the radial nerve was 1(1-3) in group1, 7(2-11) in group2, 14(7-25) in group3 and 6(3-8) in group4. It was significantly longer in group3 and significantly shorter in group1 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the musculocutaneous nerve was 16(8-28) in group1, 11(7-18) in group2, 3(2-4) in group3 and 6(3-8) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the brachial artery was 21(18-23) in group1, 7(6-7) in group2, 4(3-5) in group3 and 7(6-7) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.021. MIPO with 45°- and 90°-helical plates as well as ALPS is safely feasible and showed a significant greater distance to the radial nerve compared to straight plates. However, distances remain low, and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is used with ALPS, 45°- and 90°-helical implants. Anterior parts of the deltoid insertion will be detached using 90°-helical and ALPS implants in MIPO-technique.
The scaphotrapeziotrapezoid (STT) joint is one of the key link joints between the proximal and the distal carpal rows. We assessed the relationship between the scaphotrapezium (STm) andscaphotrapezoid (STd) joints using computerised tomographyand hypothesised the ratio of STm is =/< STd joint due to which, the possibility of failure of trapeziectomy due to metacarpal collapse is insignificant. We reviewed CT scans of wrist joints of 113 eligible patientsfrom our wrist database between 2009 and 2014 for our study. 31 patients were randomised for interobserver correlation. Reformatted multi-planar sequences were analysed. The ratio of theSTm: STdin sagittal and coronal measurementswas evaluated. Interobserver variations were assessed using the Pearson coefficient. The sex distribution included 68 males and 29 females, 49 left and 64 right wrists. The STm area was larger in 86 (76%) as compared to STd in 27(24%). Average trapezium to trapezoid ratio was 1:1.5. Ratio of area of trapezium: trapezoid joint is 0.30. The
Introduction: The Donjoy OA Orthesis has been developed to treat unicompartimental osteoarthrosis of the knee joint. The idea is to reduce the load in the affected joint compartment. Sofar only clinical evaluations and gait analysis have been published. The aim of this study is to use intraarticular pressure sensors in an
Introduction. Potential implant and technique related factors to improve patellofemoral (PF) kinematics in total knee arthroplasty (TKA) are design of trochlear geometry and patella, restoration of posterior offset, patellar tilt and avoid overstuffing. The primary aim of this prospective, matched pair study was to assess the radiographic features of PF kinematics with an