Advertisement for orthosearch.org.uk
Results 1 - 100 of 704
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 37 - 37
1 Mar 2021
Bouchard C Chan R Bornes T Beaupre L Silveira A Hemstock R
Full Access

The purpose of this study is to determine the re-operation rate following plate fixation of the olecranon with contoured anatomic plates. Plate fixation of the olecranon allows for management of different fracture patterns as well as osteotomies with anatomic reduction and stable fixation for early elbow mobilization. However, olecranon hardware prominence can be troublesome. Our hypothesis was with the newer generation of low profile contoured anatomic plates, the rate of hardware removal should be lower compared to previously described literature. Retrospective review for patients treated with operative fixation of the olecranon between 2010 and 2015 in the Edmonton zone was identified using population level administrative data. Radiographic screening of these patients was then carried out to identify those who received plate fixation. Fracture patterns were also characterized. Chart reviews followed to determine the indications for re-operation and other post-operative complications. Main outcome measures were re-operation rate and their indications, including hardware prominence. During the screening process, 600 surgically treated olecranon patients were identified and 321 patients were found to have plate fixation of the olecranon. Chart review determined 90 patients had re-operations demonstrating a 28% re-operation rate. Re-operation due to hardware prominence was found to be 15.6%. Other indications included hardware failure (5.3%), infection (2.8%), or contracture (2.8%). Compared to patients that did not require re-operation, the re-operation group had a higher incidence of Type III olecranon fractures (17.4% vs 8.4%, p = 0.036) and Monteggia pattern injuries (13.5% vs 4.9%, p = 0.008). Recent heteregenous data suggests the hardware removal rate related to implant prominence is between 17–54%. Compared to the literature, this study demonstrated a lower rate at 15.6% with contoured anatomic plating. Also, those with more complex fracture patterns were more likely to require re-operation


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims. The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. Methods. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis. Results. At 24 months, the median AOFAS score was equivalent in the two groups (nail 90 (interquartile range (IQR) 82 to 100), plate 95 (IQR 87 to 100), p = 0.478). There were statistically more complications and secondary operations after nail than plate fixation (p = 0.024 and p = 0.028, respectively). There were no other significant differences in the outcomes between the two groups. Conclusion. The functional outcome after nail and plate fixation was equivalent; however, the complication rate and number of secondary operations was significantly higher after nail fixation. These results suggest that plate fixation should usually be the treatment of choice for unstable ankle fractures in the elderly. Cite this article: Bone Joint J 2023;105-B(1):72–81


Bone & Joint Open
Vol. 2, Issue 7 | Pages 522 - 529
13 Jul 2021
Nicholson JA Clement ND Clelland AD MacDonald DJ Simpson AHRW Robinson CM

Aims. It is unclear whether acute plate fixation facilitates earlier return of normal shoulder function following a displaced mid-shaft clavicular fracture compared with nonoperative management when union occurs. The primary aim of this study was to establish whether acute plate fixation was associated with a greater return of normal shoulder function when compared with nonoperative management in patients who unite their fractures. The secondary aim was to investigate whether there were identifiable predictors associated with return of normal shoulder function in patients who achieve union with nonoperative management. Methods. Patient data from a randomized controlled trial were used to compare acute plate fixation with nonoperative management of united fractures. Return of shoulder function was based on the age- and sex-matched Disabilities of the Arm, Shoulder and Hand (DASH) scores for the cohort. Independent predictors of an early recovery of normal shoulder function were investigated using a separate prospective series of consecutive nonoperative displaced mid-shaft clavicular fractures recruited over a two-year period (aged ≥ 16 years). Patient demographics and functional recovery were assessed over the six months post-injury using a standardized protocol. Results. Data from the randomized controlled trial consisted of 86 patients who underwent operative fixation compared with 76 patients that united with nonoperative treatment. The recovery of normal shoulder function, as defined by a DASH score within the predicted 95% confidence interval for each respective patient, was similar between each group at six weeks (operative 26.7% vs nonoperative 25.0%, p = 0.800), three months (52.3% vs 44.2%, p = 0.768), and six months post-injury (86.0% vs 90.8%, p = 0.349). The mean DASH score and return to work were also comparable at each timepoint. In the prospective cohort, 86.5% (n = 173/200) achieved union by six months post-injury (follow-up rate 88.5%, n = 200/226). Regression analysis found that no specific patient, injury, or fracture predictor was associated with an early return of function at six or 12 weeks. Conclusion. Return of normal shoulder function was comparable between acute plate fixation and nonoperative management when union was achieved. One in two patients will have recovery of normal shoulder function at three months, increasing to nine out of ten patients at six months following injury when union occurs, irrespective of initial treatment. Cite this article: Bone Jt Open 2021;2(7):522–529


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1095 - 1101
1 Aug 2017
Fuglesang HFS Flugsrud GB Randsborg PH Oord P Benth JŠ Utvåg SE

Aims. This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. Patients and Methods. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Results. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Conclusion. Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095–1101


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 275 - 276
1 May 2010
Ashraf M Davarinos N Ellanti P Thakral R Nicholson P Morris S Mc elwain J
Full Access

Introduction: Weber B fractures are one of the most common fractures of the ankle. Unstable fractures are treated with lateral plating and a lag screw. Another method of fixation is antiglide plating, this concept was first introduced by Brunner and Weber in 1982. Manoli and Schaeffer in 1987, showed that fixation by antiglide plate demonstrated superior static biomechanical properties compared to lateral plating. However there are some shortcomings in their study and hence we decided to perform our biomechanical study. The shortcomings of the Manoli study are. They did not use an interfragmentary lag screw for lateral plate fixation. It was a cadaveric study where the bone does not accurately represent the live bone. The quality of the bone ranging from normal to osteoporotic bone varies from cadaver to cadaver and hence there is no uniformity between the samples. Materials and Methods: We used 4th generation composite bone models validated to closely simulate human bone characteristics for fracture toughness, tensile strength, compressive strength, fatigue crack resistance and implant subsidence. 4th generation composite bone model provides uniformity of test samples which is not achievable in cadaveric studies. These bones were custom made for the experiment. We used two sets of bones, one representative of normal bone (Set A n=10) and the other of osteoporotic bone quality (Set B n=10). Each of the sets A & B will have two types of fixations for artificially created Weber B Fractures. Lateral plate with interfragmentary lag screw. Antiglide plate with interfragmentary lag screw. The strength of the fixation was measured by restressing the bone until the fixation failed using an Instron machine which simultaneously applied torque and compressive forces to the fibular construct. The resulting data was analysed on a computer and statistical analysis was performed. Results: When the two fixation constructs were stressed to failure, the lateral plate construct demonstrated less stiffness (3–5Nm/degree) and failed at lower energy levels (250Nm). Similar values obtained for the antiglide system were, stiffness of 12–16Nm/degree and energy absorbed to failure 350–450Nm. Antiglide plating was significantly more stable in the osteoporotic fibula. Conclusion: Antiglide plating with lag screw is much more stable than lateral plating. It is suitable for treatment without plaster cast post operatively. It results in a more stable fixation in osteoporotic bone


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 22 - 22
7 Nov 2023
Du Plessis J Kazee N Lewis A Steyn S Van Deventer S
Full Access

The choice of whether to perform antegrade intramedullary nailing (IMN) or plate fixation (PF) poses a conundrum for the surgeon who must strike the balance between anatomical restoration while reducing elbow and shoulder functional impairment. Most humeral middle third shaft fractures are amenable to conservative management given the considerable acceptable deformity and anatomical compensation by patients. This study is concerned with the patient reported outcomes regarding shoulder and elbow function for IMN and PF respectively. A prospective cohort study following up all the cases treated surgically for middle third humeral fractures from 2016 to 2022 at a single centre. Telephonically an analogue pain score, an American Shoulder and Elbow Society (ASES) score for shoulder function and the Oxford Elbow score (OES) for elbow function were obtained. One hundred and three patients met the inclusion criteria. Twenty four patients participated in the study, fifteen had IMN (62.5%) and nine had PF (37.5%.). The shoulder function outcomes showed no statistical difference with an average ASES score of sixty-six for the IMN group and sixty-nine for the PF group. Women and employed individuals expressed greater functional impairment. Hand dominance has no impact on the scores of elbow and shoulder function post operatively. The impairment of abduction score post antegrade nailing was higher in the antegrade nailing group than the plated group. The OES demonstrated greater variance in elbow function in the PF group with the IMN group expressing greater elbow disfunction. This study confirms that treatment of middle third humerus shaft fractures by plate fixation is marginally superior to antegrade intramedullary nailing in preserving elbow function and abduction ability


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims. Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Methods. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed. Results. A total of 49 patients with a mean age of 31 years (16 to 74) and a mean duration of nonunion of 3.6 years (0.4 to 16) were included. Postoperatively, the nonunion healed in 47 patients (96%) as shown on CT scans. The mean time to union was 4.2 months (3 to 12). Due to impingement of the plate on the volar rim of the radius and functional limitation, the hardware was removed in 18 patients. At a median follow-up of 38 months in 34 patients, the mean active range of motion (ROM) improved significantly from 89° to 124° (SD 44°; p = 0.003). The mean grip strength improved significantly from 52% to 79% (SD 28%; p < 0.001) of the contralateral side. The mean PRWHE score improved significantly from 66 to 17 points (SD 25; p < 0.001). Conclusion. Locking plate fixation supplemented with autologous cancellous bone grafting is a successful form of treatment for scaphoid nonunion. Functional outcomes improve with the passage of time, and mid-term results are excellent with a significant improvement in ROM, grip strength, and functional outcome as measured by the PRWHE. Cite this article: Bone Joint J 2020;102-B(12):1697–1702


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 67 - 67
1 Apr 2017
Ezzat A Iobst C
Full Access

Background. Plate fixation is one of several options available to surgeons for the management of pediatric femur fractures. Recent literature reports distal femoral valgus can be a complication following lateral plate fixation of femur fractures. We report on a case of extreme distal femoral valgus deformity and a lateral dislocation of the patella four years after having plate fixation of a left distal femoral fracture. Method. A single case was anonymised and retrospectively reviewed through examination of clinical and radiographic data. Results. A 15 year old male presented with 35 degree femoral valgus deformity, one inch leg length discrepancy, painful retained hardware and a lateral dislocation of the patella four years after undergoing lateral plate fixation of a left distal femur fracture. The fracture site healed after plate insertion, but later the patient reported worsening in alignment of lower extremity and complained of pain in the limb. Antero-posterior and lateral radiographs of the femur revealed 35 degrees of left distal femoral valgus. The previous femoral plate migrated proximally and was encased in bone. Due to plate migration, screws that were originally in the distal femoral metaphysis were protruding through the femoral shaft into soft tissues of the medial thigh. Successful treatment involved removal of prominent distal screws and use of a Taylor Spatial external fixator frame to correct the deformity. Lateral soft tissue release was performed to allow patellar relocation. At 12 weeks follow up leg alignment was restored, pain resolved and the patient was mobilising. Conclusion. Femoral valgus is a possible complication of lateral plate fixation in up to 30% of pediatric distal femur fractures. With this patient's combination of deformities as an example, we suggest early hardware removal after fracture union, preventing deformities developing. If plate removal is not chosen, then continued close monitoring of the patient is necessary until skeletal maturity. Level of Evidence. Type 4 (case report)


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims. The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. Patients and Methods. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH). Results. The mean forward elevation in the LP and FA groups was 125.3° (. sd. 21.4) and 148.9° (. sd. 19.8), respectively (p = 0.042), while other clinical factors showed no statistically significant differences between the groups. The changes in NSA and HHH immediately after the operation and at final follow-up were significantly better in the FA group than in the LP group (p = 0.015 and p = 0.021, respectively). Conclusion. For comminuted proximal humeral fractures in osteoporotic patients, locking plate fixation with a fibular strut allograft shows satisfactory short-term results with respect to humeral head support and maintenance of reduction, and may reduce the incidence of complications associated with fixation using a locking plate alone. Cite this article: Bone Joint J 2019;101-B:260–265


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 58 - 58
1 Dec 2022
Lemieux V Afsharpour S Nam D Elmaraghy A
Full Access

Operative management of clavicle fractures is increasingly common. In the context of explaining the risks and benefits of surgery, understanding the impact of incisional numbness as it relates to the patient experience is key to shared decision making. This study aims to determine the prevalence, extent, and recovery of sensory changes associated with supraclavicular nerve injury after open reduction and plate internal fixation of middle or lateral clavicle shaft fractures. Eighty-six patients were identified retrospectively and completed a patient experience survey assessing sensory symptoms, perceived post-operative function, and satisfaction. Correlations between demographic factors and outcomes, as well as subgroup analyses were completed to identify factors impacting patient satisfaction. Ninety percent of patients experienced sensory changes post-operatively. Numbness was the most common symptom (64%) and complete resolution occurred in 32% of patients over an average of 19 months. Patients who experienced burning were less satisfied overall with the outcome of their surgery whereas those who were informed of the risk of sensory changes pre-operatively were more satisfied overall. Post-operative sensory disturbance is common. While most patients improve, some symptoms persist in the majority of patients without significant negative effects on satisfaction. Patients should always be advised of the risk of persistent sensory alterations around the surgical site to increase the likelihood of their satisfaction post-operatively


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_18 | Pages 3 - 3
1 Nov 2017
Duckworth A Clement N White T Court-Brown C McQueen M
Full Access

The aim of this prospective randomized controlled trial was to compare patient reported and functional outcomes, complications and costs for displaced olecranon fractures managed with either tension band wire (TBW) or plate fixation. We performed a registered prospective randomized, single blind, single centre trial in 67 patients aged between 16–74 years with an acute isolated displaced fracture of the olecranon. Patients were randomised to either TBW (n=34) or plate fixation (n=33). The primary outcome measure was the Disability Arm Shoulder and Hand (DASH) score at one-year. The baseline demographic and fracture characteristics of the two groups were overall comparable. The one-year follow-up was 85percnt;. There was a significant improvement in elbow function over the 12 months following injury in both groups (p<0.001). At one-year following surgery the DASH for the TBW group was not statistically different to the plate fixation group (12.8 vs 8.5; p=0.315). There was no significant difference between groups in terms of range of movement, Broberg and Morrey Score, Mayo Elbow Score or the DASH at all assessment points over the one-year following injury (all p≥0.05). Complication rates were significantly higher in the TBW group (63percnt;vs38percnt;; p=0.042), predominantly due to a significantly higher rate of symptomatic metalwork removal (50percnt;vs22percnt;; p=0.021). In active patients with an isolated displaced fracture of the olecranon, no difference was found in the patient reported outcome between TBW and plate fixation at one year following surgery. The complication rate is higher following TBW fixation due to a high rate of symptomatic metalwork removal


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 31 - 31
1 Feb 2012
Theruvil B Rahman M Trimmings N
Full Access

We report the results of anterior plate fixation for symptomatic, mid-shaft clavicle non-union. The superior surface is most commonly used for plate fixation. To the best of our knowledge, there are no clinical reports where anterior plate fixation of the clavicle was used. We included 12 consecutive patients, with symptomatic mid-shaft clavicular non-union, aged between 23 and 56 years during a four-year period (1998-2002). The injury was secondary to RTA in 6 cases, sports-related in 5 and skiing in one. In three patients, the non-union was secondary to superior plating using one third tubular plate, in acute fractures. The most common complaint was anterior shoulder pain (12 cases) followed by brachialgia (4 patients). The operation was performed through an anterior approach. A 3.5mm reconstruction plate was contoured and fixed onto the anterior surface of the clavicle. Bone graft was used in all cases. The average follow up was 22 months. All 12 patients achieved union at an average union time of seventeen weeks. Compared to superior plating, anterior plating has the distinct advantage that the longer screws can be used (as the clavicle is a flat bone, and the AP diameter is larger compared to superoinferior diameter) thus improving the stability of fixation. Our results show that anterior clavicle fixation is safe and effective in achieving union, even in cases following failed superior plate fixation. We therefore recommend anterior plate fixation and bone grafting in symptomatic nonunions of mid third clavicle fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 32 - 32
1 May 2018
Iliopoulos E Ads T Trompeter A
Full Access

Introduction. Plate fixation for distal femoral fractures is a commonly used method of fracture stabilisation. Many orthopaedic surgeons traditionally do not allow their patients to weight bear for the first 6 weeks after surgery, fearing of loss of fracture reduction and metalwork failure. The aim of this study is to investigate whether the post-operative weight bearing status after plate fixation influences the outcome in terms of loss of reduction and metalwork failure. Materials & Methods. A retrospective data collection from all patients who treated in our hospital surgically for distal femoral fractures, from January 2015 until June 2017. Inclusion criteria were the operative treatment of these fractures with plate fixation. Patients who were treated with retrograde nail, primary total knee replacement or screw fixation were excluded from the study. Patient, injury and surgery demographic data was collected. The immediate post-operative weight bearing status of these patients was noted. Weight bearing status was divided into two groups – Group 1 (Non and touch weight bear – the non-weight bearing group) and Group 2 (Weight bear as tolerated / Full weight bear – the weight bearing group). Radiological data about fracture displacement or metalwork failure was collected at the six weeks and three months follow up after the operation, using a standardised measurement for displacement performed independently by two authors (EI, TA). Results. Of 70 patients, a total of 51 fractures treated with plate fixation were included to the study. The mean age of the cohort was 64.3 ±20.7 years with the majority of the patients being female (63%). Most of the patients (40%) had a complete articular distal femoral fracture, AO Type 33C. Thirty-nine patients (76%) were treated with one lateral distal femoral plate. The total number of the patients in group 1 was 32 (68%); with 17 patients (32%) in group 2. The weight bearing status did not correlate with the fracture type or the fixation type (p>0.05). None of the 6 weeks follow up radiographs revealed fracture displacement in both study groups. Four of the patients from the non-weight bearing group had >1mm displacement at the 3 months' follow-up radiographs. Fisher's exact test revealed no statistically significant difference between the two study groups in both follow-up time points (p=0.55). Two of the patients in the non-weight bearing group had their plate broken at the 3 months follow up and required revision fixation. Conclusion. By reviewing the outcomes in terms of fracture displacement and metalwork failure following plate fixation of distal femoral fractures, early weight bearing of these patients do not jeopardise the outcome of the operation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 131 - 131
1 Sep 2012
Ashman BD Slobogean GP Stone T
Full Access

Purpose. Open reduction and plate fixation of displaced mid-shaft clavicle fractures has gained significant popularity following a recent multi-center randomized control trial. The purpose of this study is to describe the incidence of reoperation following plate fixation of displaced mid-shaft clavicle fractures. The secondary objective is to determine if plate design influences the incidence of reoperation. Method. A retrospective search of our hospital database was performed to identify subjects treated with plate fixation for a displaced clavicle fracture between 2001 and 2009. Radiographs and medical records were used to identify demographic data, fracture classification, plate design, and reoperation events. Only mid-shaft (AO/OTA 15-B) fractures treated with either a Low-Contact Dynamic Compression (LCDC) plate or Pre-contoured Locking (PCL) plate were included. Results. 144 subjects were included in the study. The mean age was 36 years (95% CI 33 38 years) and the mean duration of follow-up was 60 weeks (95% CI 46 74 weeks). 60% of included fractures were wedge pattern (15-B2), followed by 35% simple (15-B1) fractures, and 5% complex (15-B3) fracture patterns. Pre-contoured locking plates were used in 92 cases (64%) and LCDC plates were used in the remaining 52 subjects (36%). 21 subjects (15%) underwent reoperation: 17% of subjects treated with LCDC plates and 13% of subjects treated with PCL plates (p=0.62). Indications for reoperation included painful hardware (86%), hardware failure (9%), and refracture (5%). There was no association between reoperation and age (p = 0.23), gender (p = 0.56), fracture type (p = 0.53), or plate design (p = 0.49). Conclusion. This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common and is primarily due to painful hardware. No difference in reoperation rates between LCDC and pre-contoured plates could be detected in the current sample size


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 87 - 87
1 Aug 2020
Gusnowski E Schneider P
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO-OTA distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO-OTA classification or a two-tailed independent samples t-tests for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, six dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO-OTA classification versus six dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9 degrees, SD 9.3, n=257, volar 61.3 degrees, SD 11.5, n=1906) and extension (dorsal 60 degrees, SD 12, n=257, volar 62.8 degrees, SD 11.4, n=1906) were significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5-degrees, which is unlikely to be clinically significant. Additionally, there was no significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 25 - 25
1 May 2012
Savaridas T Gaston M Wallace R Salter D Simpson A
Full Access

Fractures repair by two mechanisms; direct fracture healing and indirect fracture healing via callus formation. Research concerning the effects of bisphosphonate on fracture repair has solely assessed indirect fracture healing. Patients with osteoporosis on bisphosphonates continue to sustain fragility fractures. A proportion of osteoporotic fractures require plate fixation. Bisphosphonates impair osteoclast activity and therefore, may adversely affect direct fracture healing that predominates with plate fixation. Five skeletally mature Sprague-Dawley rats received daily subcutaneous injections of 1mg/kg Ibandronate (IBAN). Similarly, five control rats received saline (CONTROL). Three weeks following commencement of injections a tibial osteotomy was rigidly fixed with compression plating similar to that seen in routine clinical practice. Fracture healing was monitored with radiographs. Six weeks post plate fixation, animals were sacrificed. Radiographs were performed of the extricated tibiae following plate removal. The visibility of the osteotomy site was scored as totally visible, partially visible or absent as previously described. Mechanical testing was conducted on the healing osteotomies via 4-point bending. Fractures healed without visible external callus. In the IBAN group three animals had totally visible osteotomy lines and two had partially visible osteotomy lines. The CONTROL group had three animals with absent osteotomy lines and two with partially visible osteotomy lines. The mean (±SD) stress at failure for the healing tibial osteotomies at 6 weeks was 28.8 (±23.97)MPa in the IBAN group and 37.4(±29.20) MPa in the CONTROL group (p=0.62). Our results indicate that Ibandronate adversely affected direct fracture repair as demonstrated by the radiographic density of the fracture line. The strength of the repair was reduced but this did not reach statistical significance. Our results suggest that a sample size of 220 animals is required to detect a 15% difference (alpha 0.05, beta 0.2) which suggests the effect of bisphosphonates on direct fracture repair may be small


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 22 - 22
1 May 2017
Farrell B Lin C Moon C
Full Access

Background. Surgical management of calcaneus fractures is demanding and has a high risk of wound complications. Traditionally these fractures are managed with splinting until swelling has subsided. We describe a novel protocol for the management of displaced intra-articular calcaneus fractures utilising a temporizing external fixator and staged conversion to plate fixation through a sinus tarsi approach. The goal of this technique is to allow for earlier treatment with open reduction and internal fixation, minimise the amount of manipulation required at the time of definitive fixation and reduce the wound complication rate seen with the extensile approach. Methods. The records of patients with displaced calcaneus fractures from 2010–2014 were retrospectively reviewed. A total of 10 patients with 12 calcaneus fractures were treated with this protocol. All patients underwent ankle-spanning medial external fixation within 48 hours of injury. Patients underwent conversion to open plate fixation through a sinus tarsi approach when skin turgor had returned to normal. Time to surgery, infection rate, wound complications, radiographic alignment, and time to radiographic union were recorded. Results. The average Bohler's angle improved from 13.2 (range −2 to 34) degrees preoperatively to 34.3 (range 26 to 42) degrees postoperatively. The average time from external fixation to conversion to internal fixation was 4.8 (range 3 to 7) days. There were no immediate post-surgical complications. The average time to weight bearing was 8.5 weeks. The average time to radiographic union was 9.5 (range 8 to 12) weeks. There were no infections or wound complications at the time of last follow-up. Conclusions. Early temporizing external fixation for the acute management of displaced calcaneus fractures is a safe and effective method to reduce and stabilise the foot and may decrease the time to definitive fixation. In our series there were no complications related to the use of the external fixator. Level of Evidence. IV Retrospective case series


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 644 - 648
1 Aug 1988
Clifford R Beauchamp C Kellam J Webb J Tile M

The results of immediate plate fixation of 97 open fractures of the tibial shaft in 95 patients are reported. Significant joint stiffness occurred in 11.4% and angular malunion of greater than 5 degrees in any plane was seen in 3.1%. The infection rate was 10.3%. However, even in those cases which develop delayed union or other complications, plate fixation of open fractures can produce excellent recovery of limb function


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 257 - 257
1 May 2009
John J Miller D Ford DJ Hay SM Cool P
Full Access

Tension band wire fixation continues to be the most popular method of fixation for displaced olecranon fractures despite several biomechanical studies questioning the validity of the tension band concept. Our aim was to compare the outcome of the tension band wire (TBW) method with plate fixation. 58 consecutive olecranon fractures underwent internal fixation in 58 patients between September 2000 and December 2004. There were 30 male and 28 female with a mean age at the time of surgery of 52.5 years for the TBW group (range 19 to 88) and 46.1 for the plate group (range 19 to 72). Patients were excluded if they were less than 16 years of age. Choice of fixation was based on surgeon preference, fracture pattern and presence of associated injuries. 43 patients were managed with the AO tension band technique and 15 with plate fixation. Clinical assessment and functional analysis was performed using Helm’s scoring system. Radiographic assessment was performed to assess the quality of reduction. All fractures were displaced and classified according to Colton’s classification. Mean follow up was 13 months (range 6 to 18) and similar for the two groups. For the TBW group 41 (95 %) had a fair or good result. 27 (62.8%) patients had symptomatic metal prominence requiring implant removal. In the plate fixation group 14 (94%) had a fair or good functional result despite having more complex fractures. Only 2 (18%) patients required implant removal for symptomatic metalwork, including one failure due to a technical problem. Similar functional results were seen with plating and tension band wiring of displaced olecranon fractures. Despite meticulous technique, tension band wire fixation still has an unacceptably high complication rate with symptomatic metal prominence requiring further surgery. To avoid this problem, we recommend plating, even for the more simple olecranon fractures


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim. The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia. Patients and Methods. An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates. Results. Mean NHS and PSS costs were significantly lower for patients treated with an intramedullary nail than for those treated with a locking plate (-£970, 95% confidence interval (CI) -1685 to -256; p = 0.05). There was a small increase in QALYs gained in the nail fixation group (0.01, 95% CI -0.03 to 0.06; p = 0.52). The probability of cost-effectiveness for nail fixation exceeded 90% at cost-effectiveness thresholds as low as £15 000 per additional QALY. The cost-effectiveness results remained robust to several sensitivity analyses. Conclusion. This trial-based economic evaluation suggests that nail fixation is a cost-effective alternative to locking plate fixation. Cite this article: Bone Joint J 2018;100-B:624–33


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1665 - 1676
1 Dec 2017
Stinton SB Graham PL Moloney NA Maclachlan LR Edgar DW Pappas E

Aims. To synthesise the literature and perform a meta-analysis detailing the longitudinal recovery in the first two years following a distal radius fracture (DRF) managed with volar plate fixation. Materials and Methods. Three databases were searched to identify relevant articles. Following eligibility screening and quality assessment, data were extracted and outcomes were assimilated at the post-operative time points of interest. A state-of-the-art longitudinal mixed-effects meta-analysis model was employed to analyse the data. Results. The search identified 5698 articles, of which 46 study reports met the selection criteria. High levels of disability and impairment were reported in the immediate post-operative period with subsequently a rapid initial improvement followed by more gradual improvement for up to one year. The results highlight that the period associated with the greatest physical recovery is in the first three months and suggest that the endpoint of treatment outcomes is best measured at one year post-surgery. Conclusion. Clinically meaningful improvements in outcomes can be expected for 12 months, after which progress plateaus and reaches normal values. This paper adopted a novel approach to meta-analyses in that the research question was of a longitudinal nature, which required a unique method of statistical analysis. Cite this article: Bone Joint J 2017;99-B:1665–76


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_8 | Pages 7 - 7
1 May 2021
Ross L Keenan O Magill M Clement N Moran M Patton JT Scott CEH
Full Access

Debate surrounds the optimum operative treatment of periprosthetic distal femoral fractures (PDFFs) at the level of well fixed femoral components; lateral locking plate fixation (LLP-ORIF) or distal femoral replacement (DFR). To determine which attributed the least peri-operative morbidity and mortality we performed a retrospective cohort study of 60 consecutive unilateral PDFFs of Su types II (40/60) and III (20/60) in patients ≥60 years; 33 underwent LLP-ORIF and 27 underwent DFR. The primary outcome measure was reoperation. Secondary outcomes included perioperative complications and functional mobility status. Kaplan Meier survival analysis was performed. Cox multivariable regression analysis identified risk factors for reoperation after LLP-ORIF. Mean length of follow-up was 3.8 years (range 1.0–10.4). One-year mortality was 13% (8/60). Reoperation rate was significantly higher following LLP-ORIF: 7/33 vs 0/27, p=0.008. For the endpoint reoperation, five-year survival was better following DFR: 100% compared to 70.8% (51.8 to 89.8 95%CI) (p=0.006). For the endpoint mechanical failure (including radiographic loosening) there was no difference at 5 years: ORIF 74.5% (56.3 to 92.7); DFR 78.2% (52.3 to 100), p=0.182). Reoperation following LLP-ORIF was independently associated with medial comminution: HR 10.7 (1.45 to 79.5, p=0.020). Anatomic reduction was protective against reoperation: HR 0.11(0.013 to 0.96, p=0.046). When inadequately fixed fractures were excluded differences in survival were no longer significant: reoperation (p=0.156); mechanical failure (p=0.453). Reoperation rates are higher following LLP-ORIF of low PDFFs compared to DFR. Where adequate reduction, proximal fixation and augmentation of medial comminution is used there is no difference in survival between LLP-ORIF and DFR


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages 65 - 65
1 Mar 2002
Segonds J Alnot J
Full Access

Purpose: Nonunion of the humeral shaft is an uncommon complication of diaphyseal fractures. The rate of nonunion reported in the literature is nevertheless very variable, ranging from 1 to 10%. There are many causal and favouring factors often related to a technical error or poor therapeutic indication. There are several ways to treat humeral shaft fractures (orthopaedic treatment, locked centromedullary nail, ascending pinning, plate fixation, external fixation). Rigorous technique and rigorous indications are the key to success. Material and methods: We reviewed 35 patients with aseptic nonunion of the humeral shaft between 1995 and 2000. The nonunion resulted from imperfect initial treatment in 24. Mean age was 44 years; fracture of the mid third of the shaft was oblique or transverse in general; all types of initial treatments had been used but ascending pins predominated (16 cases). All patients were reoperated for external plate fixation with a cancellous or corticocancellous bone graft after identifying the radial nerve. Results: All patients achieved consolidation within a mean delay of 15 weeks with good shoulder (mean elevation 135°) and elbow (mean 10–130°) amplitudes. There were two cases of transient radial paresis with spontaneous recovery. Only two patients experienced mild arm pain that did not required long-term antalgesic treatment. There were no injuries to the femorocutaneous nerve at the site of graft harvesting. Discussion: Plate fixation for nonunion of the humerus is widely described in the literature. The main complications with this method include radial paralysis and infection. For this reason, several recent reports have advocated locked nailing or external fixation of the Ilizarov type. These methods are technically difficult and are not free of their own complications. We thus recommend screw plate fixation (eight cortical screws on either side of the nonunion) associated with cancellous bone grafts. The results in our series with almost no complications favour this option


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 472 - 472
1 Aug 2008
Sharmah S Ramesh B Bastawrous SS Smith I
Full Access

There are many management solutions for the fixation of Periprosthetic fractures with intact stem of Hip and shoulder arthroplasties. The Bio Mechanics of single plate application are unlikely to be strong enough to commence mobilisation and its effectiveness against torsional strain with an osteoporotic bone quality is of concern. Double plate fixation as discussed at the last South African Orthopaedic Congress by Mr Floyd et al is another option but this again may have some biomechanical concerns and biological compromise at the fracture site due to periosteal stripping. Implant revision with a longer stem is a bigger surgical insult to a potentially frail group of patients with questionable bone quality. We report a short series of 16 peri-prosthetic fractures with intact stem that are managed with Zimmer cable plate fixation System. The results were very satisfactory and we consider this an attractive option to be considered in the management of this difficult presentation. This is a retrospective study. We present the results of 13 Periprosthetic Femoral Shaft fractures and 3 humeral periprosthetic fractures in 16 patients treated with cable plate fixation system. Majority of the patients were over 60 years with an ASA rating of 3–4. The procedures were performed in a district general hospital in the UK between August 2001 to December 2005. The patients presented with in 1–20 years following initial Arthroplasty. All the fractures were fixed with Zimmer cable plate fixation system. An 8 hole plate was most commonly used for femoral fractures through the lateral approach for TYPE 2 fractures. The proximal end of the plate was secured with 3–4 cable ties. Early partial weight bearing was encouraged. The majority of the patients were discharged within 12 weeks. Of the 3 humeral fractures union was achieved at 12 weeks in 2. There was 1 case of implant failure due to a further fracture noted in a manic depressive patient, who was not compliant. All proximal femoral fractures showed evidence of clinical and radiological union by 6 months. The majority (7/13) had united within 20 weeks. There were no complications noted. We recommend this effective method should seriously be considered in the management of this difficult and increasingly occurring complication in a frail population


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 364 - 364
1 May 2009
Kanagaraj K Kotecha A Debnath UK Nathdwarwala Y
Full Access

Background: First MTP joint arthrodesis is a well established and very common procedure for painful arthrosis. Plate fixation method has been used with successful outcome (97–100%) by few authors but it is yet to be accepted universally for fear of complications. Aim: To evaluate clinical and radiological outcome of first MTP fusion using low profile Acumed plate. Methods: We retrospectively reviewed 125 patients who had 1st MTP arthrodesis (over 6 year period) for painful Hallux Rigidus not relieved by conservative means and for rheumatoid forefoot reconstruction. The preoperative evaluation included a subjective questionnaire, physical exam, AOFAS hallux score and radiographic measurements. Post-operatively, all patients were mobilised with heel weight bearing shoes for six weeks. All patients had follow up of minimum 6 months(range 6 months to 6 years). At the final follow-up all patients had answered a questionnaire which evaluated any limitations of daily activity and restrictions in footwear. Radiological measurements included union of the arthrodesis and various angles (valgus, intermetatarsal and dorsiflexion). Results: Of the 125 patients we had final reviews for 103 patients. The mean AOFAS improved from 40 to 82. The individual components of AOFAS i.e. pain, walking ability and alignment improved significantly. All patients but one had radiological evidence of fusion at mean of 6 weeks (range 6–8weeks) allowing them to walk with normal footwear. The mean dorsiflexion angle was 15° (range 13 °–18 °). The patient with non-union had re-arthrodesis with bone grafts using the revision plate. Two patients with rheumatoid arthritis required removal of plate for infection and wound breakdown. No plate failure occurred in any of the patients. Conclusion: The plate fixation is a reliable method for 1st MTP joint fusion that allows for a predictable fusion in a satisfactory alignment with low complication rate. The stability of the fixation allows for early mobilization without need for plaster immobilization and early return to functional activities


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 57 - 57
1 Apr 2013
Stephan D Hoffmann S Roth KE Augat P
Full Access

Introduction. Metatarsocuneiform (MTC) fusion is a standard treatment for arthritis, instability, and deformity of these joint. The MTC fusion achieves a good clinical outcome, but nonunion rates up to 12% have been reported. There are different methods for fixation of first MTC joint arthrodesis. Our aim was to compare the biomechanical characteristic of internal and external fixation constructs. Hypothesis. Plantar plate fixation provides higher construct stiffness and endurance stability than intraosseous fixation. Materials & Methods. Seven pairs of fresh-frozen human specimens were used in a matched pair test. In one foot the MTC joint was supplied with a plantar plate. On the other foot intraosseous-screw fixation was perfomed. The specimen constructs were loaded in a 4 point bending test. Parameters obtained were initial stiffness and number of cycles to failure. Failure was defined as displacement of more than 3 mm plantar gapping. Results. The intraosseous-screw fixation group showed significantly (p=0.002) less cycles to failure (n=2946) than the plantare plate (n=7517). The initial stiffness was 131 N/mm for the plantare plate and 43 N/mm for the intraosseous implant (p=0.005). Discussion & Conclusion. Plantar plate fixation of the first MTC fusion created a stronger and stiffer construct than intraosseous fixation. This was likely due to the plantar and dorsal implant position. A stiffer construct can reduce the risk of non-union and shorten the period of nonweight-bearing


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 66 - 66
1 Mar 2008
Droll K Perna P McConnell A Beaton D McKee M Schemitsch E
Full Access

The purpose of this study was to investigate patient-based functional outcome and objectively measure strength following plate fixation of fractures of both bones of the forearm. Twenty-five subjects were clinically and radiographically reviewed. Strength of elbow flexion, extension, supination, pronation, wrist flex-ion, extension and grip were significantly reduced in the injured arm. (p< 0.01, range 62%–84% of normal). Mean (+/− SE) DASH score was 19.5 +/− 4.0 and eighty-eight percent (22/25) scored good to excellent on the Gartland-Werley scale (mean 4.04 +/− 0.91). No statistical difference in mean maximal radial bow (MRB) or location of MRB between injured and non-injured arm was found. The purpose of this study was to investigate functional outcome and objectively measure strength following plate fixation of fractures of both bones of the forearm (BBOF). Anatomic reduction was associated with good to excellent functional outcome. However strength of the elbow, forearm, wrist and grip were significantly reduced in the injured arm. Despite good to excellent functional outcome following this injury, significant reduction in strength of the upper extremity should be expected, and thus is an area for potential improvement in post-operative care. Twenty-five subjects (M/F 19/6, mean age 47.6 (range 20–71)) treated with plate fixation for fractures of BBOF were clinically and radiographically reviewed. Mean duration of follow-up was 5.7 years (range 2–13.4 y). Post-operative protocol included short-term immobilization followed by active-assisted ROM and strengthening starting between four and six weeks. Isometric muscle strength was objectively measured with the Baltimore Therapeutic Equipment work simulator (model WS-20). Strength of elbow flexion (72% of non-injured arm, p< 0.0001), elbow extension (84%, p=0.0004), forearm supination (75%, p=0.005), forearm pronation (69%, p< 0.0001), wrist flexion (81%, p=0.009), wrist extension (62%, p< 0.0001) and grip (70%, p< 0.0001) were all significantly reduced in the injured arm. Mean (+/− SE) DASH and Gartland-Werley scores were 19.5 +/− 4.0 (range 0–61) and 4.04 +/− 0.91 (range 0–15) respectively. Eighty-eight percent (22/25) scored good to excellent on the Gartland-Werley scale. No statistical difference in mean maximal radial bow (MRB) between injured and non-injured arm was found (mean +/− SE, 1.42 +/− 0.07 vs 1.58 +/− 0.05 respectively) or in location of MRB (61% vs 59%)


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 336 - 336
1 Sep 2005
Droll K Perna P McConnell A Beaton D Schemitsch E McKee M
Full Access

Introduction and Aims: Patient-based functional outcome and strength following plate fixation of diaphyseal fractures of the radius and ulna is unknown. Therefore, the purpose of this study was to investigate patient-based functional outcome and objectively measured strength following plate fixation of fractures of both bones of the forearm (BBOF). Method: Twenty-five subjects (M/F 19/6, mean age 47.6 (range 20–71) treated with plate fixation for fractures of BBOF were clinically and radiographically reviewed. Mean duration of follow-up was 5.7 years (range 2–13.4 years). Post-operative protocol included short-term immobilisation followed by active-assisted ROM and strengthening starting between four and six weeks. All subjects were assessed in person at follow-up with a detailed examination of strength of their injured and non-injured arms. Isometric muscle strength was objectively measured with the Baltimore Therapeutic Equipment work simulator (model WS-20). Standardised anteroposterior and lateral radiographs were made of both forearms. Results: Strength of elbow flexion (72% of non-injured arm, p< 0.0001), elbow extension (84%, p=0.0004), forearm supination (75%, p=0.005), forearm pronation (69%, p< 0.0001), wrist flexion (81%, p=0.009), wrist extension (62%, p< 0.0001) and grip (70%, p< 0.0001) were all significantly reduced in the injured arm. Mean (+/− SE) DASH and Gartland-Werley scores were 19.5 +/− 4.0 (range 0–61) and 4.04 +/− 0.91 (range 0–15) respectively. Eighty-eight percent (22/25) scored good to excellent on the Gartland-Werley scale. No statistical difference in mean maximal radial bow (MRB) between injured and non-injured arm was found (mean +/− SE, 1.42 +/− 0.07 vs 1.58 +/− 0.05 respectively) or in location of MRB (61% vs 59%). Conclusion: Restoration of anatomic alignment with stable internal fixation following BBOF fracture results in good to excellent functional outcome. Despite this, significant reduction in strength of the elbow, forearm, wrist and grip should be expected following this injury, and is an area for potential improvement in post-operative care


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 84
1 Mar 2002
Coetzee E Revelas A
Full Access

Reviewing 40 consecutive cases over a two-year period, we tested the efficacy of variable screw plate fixation postoperatively. A Codman plate was used in all cases. We compared radiological preoperative measurements of the kyphotic angle and disc height with immediate postoperative measurements and measurements at a mean of eight months postoperatively. In no case was there an increase in kyphotic angle. Disc height remained within two mm of that shown on immediate postoperative radiographs. We concluded that satisfactory results are obtained with variable screw plate fixation, with no compromised stability


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 384 - 384
1 Jul 2008
Haidar S Joshy S Charity R Ghosh S Tillu A Deshmukh S
Full Access

Purpose: Management of the unstable or comminuted displaced fractures of the distal radius is difficult. We report our experience treating these fractures with AO volar plate fixation. An attempt to introduce a new radiological classification for the accuracy of surgical reduction is made. The classification includes 10 criteria and 100 points. Methods: 124 patients had volar plate fixation performed between June 2000 and May 2003 using AO volar plate. We reviewed clinically and radiologically 101 patients; 60 were type C and 41 were type A (after failed conservative treatment). The average follow up is 37 months (24 – 57). The average age is 46 years (19 – 81). Postoperative regimen consisted of immediate physiotherapy and a wrist splint for three weeks. Cooney’s modification of Green and O’Brien and Sarmiento’s modification of Gartland and Werley were used for clinical assessment. Lidstorm and Frykman used for radiological assessment. Results: At final follow up the means of distal radius parameters were: volar tilt of 9 degrees, radial inclination of 22 degrees, radial height is 11mm and palmer cortical angle of 32 degrees. The mean dorsiflexion was 61 degrees, palmer flexion was 59 degrees, pronation was 80 degrees and supination was 76 degrees. Grip strength was 86 percent of the opposite side. The average DASH score was 13.6. There was 14 poor results, 6 of them had significant loss the initial reduction. There was significant correlation between our classification and the clinical outcome. Conclusion: AO volar plate fixation of unstable distal radius fractures provides strong fixation that maintains reduction and allows early mobilisation


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 31 - 31
1 Sep 2014
Mughal A Kruger N
Full Access

Purpose of Study. Debate exists in the literature about the surgical management of sub-axial cervical burst fractures regarding the approach and types of fixation of these injuries. Our Acute Spinal Injury (ASCI) unit prefers anterior only cervical corpectomy and plate fixation in the management of these injuries. The objective of this study was to radiologically assess the long term outcomes (minimum 2 yrs) of our series. Patients and Methods. Patients were identified using the Acute Spinal Injury Unit (ASCI) database that had had anterior only corpectomy and plate fixation for trauma as a standardised procedure between 2006 and 2009. Initial post-op radiological review included the sagittal alignment, hardware characteristics and surgical technique. Radiological review after a minimum of 24 months involved the union, sagittal alignment, hardware characteristics, graft incorporation and adjacent level degeneration at the site of injury. Results. A total of 51 patients were identified but only 11 were available for review at the minimum 24 months. There were 10 males and 1 female with an average age of 28.1years (18–62). The follow up duration was on average 50.6months (27–71) median 60 months. The levels fused were C3-5 (2), C4-6 (5), C5-7 (3), and C4-7 (1 double level). There was NO metalwork failure, NO screw osteolysis and a varying degree of degenerative changes but a 100% FUSION RATE. The average loss of cervical lordosis was 2.5 ° over the follow up period. Conclusion. Anterior stand alone cervical corpectomy and plating alone appears to be a safe, cost effective and time saving alternative in the management of cervical burst fractures in the sub axial spine with no significant long term complications. NO DISCLOSURES


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims. Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes. Patients and Methods. A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method. Results. The median follow-up was 92 months (4 to 288). The mean MSTS 87 score was 29.1 (19 to 35), the mean MSTS 93 score was 82.2 (50 to 100) and the mean TESS score was 81.2 (43 to 100). Overall survival of the allograft was 84.8%. A total of 15 patients (33%) had a complication. Five allografts were revised for complications and one for local recurrence. Conclusion. Intercalary allografts augmented with intramedullary cement and compression plate fixation provide a reliable and durable method of reconstruction after the excision of a primary diaphyseal bone tumour, with high levels of function and satisfaction. . Cite this article: Bone Joint J 2017;99-B:973–8


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 179 - 179
1 Mar 2010
Edwards W
Full Access

Injuries to the tarsometatarsal joint complex are uncommonly recognised. Many treatment modalities have been advocated. In recent years anatomic reduction and temporary rigid fixation with trans -articular screws has become popular. This is a study conducted over a period of at least two years. It reviews the management and subsequent outcome of a series of consecutive patients with an average age of 40.1 who suffered tarsometatarsal injury, or Lisfranc fracture. Anatomic or near anatomic reduction was achieved using temporary bridging plate fixation of the TMT joints and occasionally also with second metatarsal base medial cuneiform screw fixation. Two years post surgery a good or excellent functional result was generally achieved; however midfoot stiffness was a common problem


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 263 - 263
1 Mar 2003
Aksoy C Çaolar Ö Yazycy M Surat A
Full Access

The traditional treatment method of pediatric femoral shaft fracture has been traction and spica casting.This method is safe but prolonged immobilization, frequent X-ray , pin tract infections are some of the disadvantages. Internal fixation has become an alternative treatment in especially children between 6-10 years. Surgical treatment has been advocated for children who have multiple injuries or severe head injury. Compression plate fixation provides rigid and stable fixation but requires extensive dissection. Fixation of the fractures with flex-ible intramedullary nailing is another alternative treatment method and is safe and effective especially in simple transverse and short oblique fractures.In the current study we tried to evaluate the results of flexible intramedullary nailing and compare them with compression plate fixation. Thirty four patients with 36 femoral segments were included to the study. Clinical and radiological records of the patients were evaluated retrospectively. Patient’s demographic data, mechanism of injury, type of treatment , duration of the operation ,age ,side were obtained from the files. 19 femoral segments were treated with compression plating .There were 13 male and 5 female patients in this group. The mean age was 7.7 (6-10).The mean operation time was 100 minutes.(75-160 minutes- time between entering and leaving the operation room )Average time to healing was calculated as 7.7 (4-10 ) months.In this group, four femoral segment non-unions and implant failures occured in 6-10 months time .These patients were managed with titanium elastic nail.17 femoral segments were treated with titanium elastic nail ( TEN ).There were 10 male and 6 female patients in this group.The mean age of the patients were 7.9 years ( 7-10 ) .There were four patients managed with plate fixation previously . Revision surgery was done with implant removal and open reduction.The remaining 12 patients were operated with closed reduction and nailing. The mean operation time for this group was 86 ( 45-135) minutes . No immobilization method was used and partial weigth bearing permitted after the surgery.The mean healing time was 4 ( 3-7 ) months for this group. As we compare the both groups , the results were similiar. Average operation time was shorter in the nailing group but there were no statistically significant difference between the two groups. ( p> 0.05) . Average healing time was statistically significantly shorter in the nailing group. ( p= 0.038). It is generally accepted that plating is a traditionally safe and effective method; this study demonstrates that flexible intramedullary nailing maintains shorter operation time and shorter time to healing . The lack of need of post-operative immobilization , and small incisions for the insertion of the nail which is cosmetically more acceptable are the other advantages of this method. Conclusion: Internal fixation with flexible intramedul-lary nailing of the femoral fractures in pediatric age group is an advocatable solution


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 339 - 339
1 Sep 2005
Schepers A Van der Jagt D
Full Access

Introduction and Aims: The purpose of the study was to determine whether the addition of screws improved the fixation of the tibial base plate when using an uncemented total knee replacement. Method: In June 1999 a prospective randomised double blind study on tibial base plate fixation was started at our institution after Ethics Committee approval. Patients were randomly allocated to either having or not having supplementary screws inserted through the base plate. To date, 138 arthroplasties have been performed and 119 are available for study. Of these, 56 have screws through the base plate and 63 do not. Assessment was of the position of the components of the prostheses, as well as the presence of any radiological lucent lines. Results: The study is ongoing, and updated results will be presented. After a minimum of 12 months follow-up, 27 patients have some radiolucent lines at the prosthesis-bone interface on the tibial component of the knee replacement. Fourteen occurred where screws had been used and 13 when screws had not. One tibial tray subsided into the tibia without failure of fixation. No screws had been used in this case. Statistically no difference could be demonstrated between the two groups. Conclusion: The early results of our study question the value of supplementing base plate fixation in uncemented total knee replacements, especially considering the additional cost of the screws and the potential detrimental consequences of the screws


Bone & Joint 360
Vol. 12, Issue 3 | Pages 18 - 22
1 Jun 2023

The June 2023 Foot & Ankle Roundup. 360. looks at: Nail versus plate fixation for ankle fractures; Outcomes of first ray amputation in diabetic patients; Vascular calcification on plain radiographs of the ankle to diagnose diabetes mellitus; Elderly patients with ankle fracture: the case for early weight-bearing; Active treatment for Frieberg’s disease: does it work?; Survival of ankle arthroplasty; Complications following ankle arthroscopy


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup. 360. looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims

The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs).

Methods

All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 98 - 98
1 May 2011
Khan L Wallace R Robinson C Simpson A
Full Access

Background and Aims: Plate fixation of acute mid-shaft clavicle fractures is becoming increasingly popular. However limb and life threatening complications such as injury to the subclavian vessels have been reported. One possible solution to reduce the risk of this complication is the use of unicortical screw fixation. The aim of this study was to compare biomechanical properties of pre-contoured plate fixation using different screw fixation modes in a mid-shaft clavicle fracture model. Methods: Fourth generation biomechanical clavicle sawbones with a mid-shaft osteotomy were plated in one of three modes: nonlocking bicortical, locking bicortical and locking unicortical mode. The specimens were then tested to failure in four-point bending and pull-off tests. Results: Failure due to fracture through the sawbone was more common in nonlocking bicortical mode while plate bending was more common in the locking bicortical group. The ultimate load at failure was significantly lower in the locking bicortical group compared to the nonlocking bicortical group, however there was no significant difference between the locking unicortical group and nonlocking bicortical group. In the pull-off tests 100% of nonlocking bicortical and locking bicortical plates failed by fracture of the sawbone. 100% of the locking unicortical plates failed by plate and screw pull-off from the sawbone. The load at failure was highest for the locking unicortical plate but this was not significantly different to the other groups. Conclusion: This study shows that specimens fixed with locking unicortical screw fixation withstood comparable or superior loads in four-point bending and pull-off test when compared to nonlocking bicortical and locking bicortical screw fixation. In addition both locking screws and unicortical screws appear to provide a protective effect against periprosthetic sawbone fracture. Locking unicortical screw fixation of pre-contoured plates may be a viable alternative in the fixation of mid-shaft clavicle fractures


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 451 - 451
1 Apr 2004
Schepers A van der Jagt D Agbazuc D
Full Access

In June 1999 a randomised double-blind study on tibial base plate fixation was started to determine whether, when using the Profix® total knee replacement, the addition of screws improved the fixation of the tibial base plate. To date 138 total knee arthroplasties (THAs) have been performed, 119 of which were available for study. Selected randomly, 56 patients had supplementary screws inserted through the base plate and 63 did not. After a minimum of 12 months follow-up, 27 patients had some radiolucent lines at the prosthesis-bone interface on the tibial component. These lines occurred in 14 cases with supplementary screws and 13 without screws. In one patient without supplementary screws, the tibial tray had subsided into the tibia. Statistically there was no apparent difference between the two groups. The early results of our study raise questions about the value of supplementing base plate fixation in uncemented THAs, especially considering the additional cost of the screws and their potentially detrimental consequences


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1170 - 1175
1 Nov 2004
Selber P Filho ER Dallalana R Pirpiris M Nattrass GR Graham HK

Torsional deformities of the tibia are common in children, but in the majority both the torsion and the associated disturbance of gait resolve without intervention. There are, however, a significant number of children and adults with neuromuscular disease who present with pathological tibial torsion, which may require surgical correction. We conducted a prospective study in two centres, to investigate the outcome of supramalleolar derotation osteotomy of the tibia, using internal fixation with the AO-ASIF T plate. A range of outcome variables was collected, prospectively, for 57 patients (91 osteotomies), including thigh foot angle, foot progression angle, post-operative complications and serial radiographs. Correction of thigh foot angle and foot progression angle was satisfactory in all patients. Three major complications were recorded; one aseptic nonunion, one fracture through the osteotomy site after removal of the plate and one distal tibial growth arrest. We found that supramalleolar derotation osteotomy of the tibia, with AO-ASIF T plate fixation is an effective method for the correction of torsional deformities of the tibia and the associated disturbances of gait in children and adults with neuromuscular disease, with a 5.3% risk of major complications


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 283 - 284
1 Jul 2008
JEUDY J PERNIN J CRONIER P MASSIN P
Full Access

Purpose of the study: Locked plating is an attractive alternative to external fixation for the fixation of distal shaft fractures of the radius, particularly in cases with metaphyseal comminution. The purpose of this study was to assess prospectively outcome with locked anterior plate fixation in a series of 43 complex fractures of the distal radius treated between October 2003 and November 2004. Material and methods: The AO LCP 3.5 plate (Synthes) was used. The series included 27 women and 15 men, mean age 55.5 years (range 17–83 years). We included fractures with major metaphyseal comminution according to the M.E.C classification established by Laulan (18 M2, 14 M3, and 9 M4). According to the AO classification, there were nine extra-articular fractures (eight A3 and one A2) and 35 articular fractures (ten B3, two C1, four C2, and seventeen C3). Posterior displacement was noted for 22 fractures. In eight cases plate fixation was a second intention procedure due to secondary displacement occurring on average eight days (range 3–21 days) after trauma for a fracture initially treated with infrafocal pinning. An epiphyseal locking screw was used in all cases. An antebrachiopalmar immobilization orthesis was worn for six weeks on average (range 3–9 weeks). The first-intention anterior plating was combined with an intrafocal posterior pin for 13 patients and with an external fixator in one. Radiographic outcome was reported in terms of joint congruency and using the SOFCOT symposium criteria for the 41 patients reviewed at bone healing. Results: Anatomic restitution was achieved in 23 patients (55%). There were two purely intra-articular calluses due to failure of the primary reduction, both measured less than 2 mm. Fifteen moderate misalignements (36%) were noted, most (84.7%) involving moderate sagittal inclination, the distal radioulnar index being preserved. Two major misalignments (5%) were related to early disassembly of the osteosynthesis. Conclusion: Locked anterior plating has provided promising results for maintaining radial length in distal radial fractures with major metaphyseal comminution. There remains a certain number of cases with a moderate and persistent posterior inclination and a few cases of defective intra-articular reduction


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 28 - 28
1 Jan 2004
Le Huec J Dickman C Liu M Magendie J
Full Access

Purpose: Cage fusion of the L5–S1 segment is a controversial issue due to the weak stabilisation of the spine during extension and axial rotation. Complementary fixation appears to be needed to improve stability, but the presence of the bifurcation of the great vessels is an anatomic limitation. We studied the anatomy of this area to examine the feasibility of anterior plate fixation. Material and methods: According to the recognised anatomic references (Rouvière, Bouchet and Cuilleret, Louis), a 33-mm safety zone was described at the aortoiliac and iliocaval bifurcation. This space free from contact with the greater vessels lies in front of the L5–S1 disc. Pre-operative angio-MRI was used to assess the size of this safety zone. A triangular anterior plate was designed for arthrodesis (Pyramid Sofamor Danek, USA). An L5–S1 arthrodesis was performed in 15 consecutive patients using this plate. Follow-up was one year. A video-assisted anterior retroperitoneal approach was used in all cases. The Prolo and Oswestry scores were used for the preoperative and last follow-up evaluations. Results: According to the anatomic study and the MRI views, 89% of the patients had a sufficient safety zone for plate fixation. The method was contraindicated in two patients who had a low bifurcation. Angio-MRI was found to be simple and reproducible. The MRI analysis was confirmed at surgery (no false negatives). The plate was successfully implanted in 15 patients with no contact with the great vessels. There were no serious complications (vascular, neurological, urological, digestive). The economic Prolo score was improved from 2.7 to 4.2 and the functional score from 2.6 to 4.3. The Oswestry score improved 33%. The rate of clinical success was 93% (14/15 patients). Discussion and conclusion: Implantation of an anterior plate for L5-S1 fusion is feasible. The key points are: 1) rigorous preoperative evaluation of the greater vessel bifurcation; 2) anatomic plate design; 3) appropriate surgical technique. The risk of retrograde ejaculation is related to retraction of the hypogastric plexus and should be investigated with a prospective study. This osteosynthesis technique can avoid secondary operations for fixation with pedicular or transarticular screwing


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 43 - 43
1 Feb 2012
Loveday D Sanz L Simison A Morris A
Full Access

The ITS volar radial plate (Implant Technology Systems, Graz/Austria) is a fixation device that allows for the distal locking screws to be fixed at variable angles (70°-110°). This occurs by the different material properties, with the screws (titanium alloy) cutting a thread through the plate holes (titanium). We present our experience with the ITS plate. We retrospectively studied 26 patients who underwent ITS plate fixation for unstable multifragmentary distal radial fractures (AO types A3, B2, B3, C2, C3). The surgery was performed either by a consultant orthopaedic hand surgeon or senior registrar. A volar approach was used every time and 10 cases required synthetic bone grafting. Post-operatively they were immobilised for an average of 2.5 weeks. The 26 patients had a mean age of 58 and the dominant side was affected in 46% of cases. 5 cases were open fractures and 10 cases followed failed manipulation under general anaesthesia. The average interval between injury and surgery was 7 days. Union was achieved in all cases. No implant infections, failure or tendon rupture/irritation occurred. There were two fractures which loss reduction, of which one required revision surgery. There was one case of CRPS. The six month average DASH score was 27.5. We consider the ITS plate a technically easy plate to use and a reliable implant at early follow-up. We value the versatility of its variable angle screw fixation ability for complex intra-articular distal radial fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 14 - 14
10 May 2024
Mooya S Berney M Cleary M Rowan F
Full Access

Introduction

The condition of the soft tissues surrounding an ankle fracture influences timing and treatment of injuries. Conventional treatment used an open approach to facilitate anatomical reduction and rigid internal fixation. Intramedullary devices for fibular fractures provide a safe alternative in patients in which the condition of the soft tissue envelope or the patient's co-morbidities may benefit from a less invasive approach. We compared outcomes for patients treated with open reduction internal fixation (ORIF) with those undergoing treatment with fibular nails (FN)

Methods

13 consecutive patients treated with fibular nails (FN) were compared with 13 age-matched patients that underwent open reduction and internal fixation (ORIF). All patients were followed to union. Study outcomes were time from admission to surgery, length of stay, wound failure, implant failure, revision surgery, OMAS and SF-36


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 103 - 103
1 Mar 2012
McFadyen I Curwen C Field J
Full Access

The aim of this study is to compare functional, clinical and radiological outcomes in K-wire fixation versus volar fixed-angle plate fixation in unstable, dorsally angulated distal radius fractures. Fifty-four adult patients with an isolated closed, unilateral, unstable, distal radius fracture were recruited to participate in the study. Only dorsally displaced fractures with no articular comminution were included. Patients were randomised to have their fracture treated with either closed reduction and K-wire fixation (3 wires) or fixed-angle volar plating. Both groups were immobilised in a below elbow cast for six weeks. The wires removed in the outpatients at six weeks and both groups were referred for physiotherapy. Independent clinical review was performed at three and six months post injury. Functional scoring was performed using the DASH and Gartland and Werley scoring systems. Radiographs were evaluated by an independent orthopaedic surgeon. Twenty-five patients were treated with a plate and twenty-nine with wires. There were no complications in the plate group. There were 9 complications in the K-wire group with 3 patients requiring a second operation (1 corrective osteotomy for malunion, 1 median nerve decompression and 1 retrieval of a migrated wire). The remaining complications included: 5 pin site infections (3 treated with early pin removal and 2 with oral antibiotics only), and 1 superficial radial nerve palsy. There were no tendon ruptures. Both groups scored satisfactory functional results with no statistical difference. There was a statistically significant difference in the radiological outcomes with the plate group achieving better results. We conclude that in unstable dorsally angulated distal radius fractures volar fixed-angle plate fixation is able to achieve comparable functional results to K-wire fixation with better radiological results and fewer complications. This has resulted in a change in our clinical practice


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 37 - 37
1 Nov 2016
Gupta S Kafchinski L Gundle K Saidi K Griffin A Ferguson P Wunder J
Full Access

Biological reconstruction techniques after diaphyseal tumour resection have increased in popularity in recent years. High complication and failure rates have been reported with intercalary allografts, with recent studies questioning their role in limb-salvage surgery. We developed a technique in which large segment allografts are augmented with intramedullary cement and fixed using compression plating. The goal of this study was to evaluate the survivorship, complications and functional outcomes of these intercalary reconstructions. Forty-two patients who had reconstruction with an intercalary allograft following tumour resection between 1989 and 2010 were identified from our prospectively collected database. Allograft survival, local recurrence-free, disease-free and overall survival were assessed using the Kaplan-Meier method. Patient function was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The 23 women and 19 men had a mean age of 33 years (14–77). The most common diagnoses were osteosarcoma (n=16) and chondrosarcoma (n=9). There were 9 humerus, 18 femur and 15 tibia reconstructions. At a mean follow-up of 95 months (5–288), 31 patients were alive without disease, 10 were dead of disease and 1 was deceased of other causes. There were 4 local recurrences and 11 patients developed metastatic disease. 5-year local recurrence free survival was 92%, 5-year disease-free survival was 70% and overall survival was 75%. Fourteen of 42 patients (33%) experienced complications: 5 wound healing complications, 4 infections, 2 non-unions, 2 fractures and 1 nerve palsy. Four allografts (9.5%) were revised for complications and 2 (5%) for local recurrence. Mean allograft survival was 85 months (4–288). Mean time to union was 8.2 (3–36) months for the proximal osteotomy site and 8.1 (3–23) months for the distal osteotomy site. The mean score for MSTS 87 was 29.4 (+/− 4.4), MSTS 93 was 83.7 (+/−14.8) and TESS was 81.6 (+/−16.9). An intercalary allograft augmented with intramedullary cement and compression plate fixation provides a reliable and durable method of reconstruction after tumour resection. Complication rates are comparable to the literature and are associated with high levels of patient function and satisfaction


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 43 - 43
1 Jan 2004
Biette G Laporte C Jouve F
Full Access

Purpose: We report our expeience with the medial and posteromedial approach to the humerus for plate fixation of fractures of the distal two-thirds of the humerus. Material: Fifteen patients (eleven men and four women) were treated for fractures (n=13) or nonunion (n=2) situated below the proximal third of the humerus without radial nerve involvement. Methods: Eight patients were installed in the supine position for median approach between the humerus bundle and the median nerve anteriorly and the ulnar nerve posteriorly. The posteriomedian approach, with the ulnar nerve posteriorly and the brachial triceps anteriorly, was used for seven other patients installed in the prone position. The fixation plate applied to the medial aspect allowed at least six corticals on either side of the fracture line. The patients were immobilised for 45 days. Passive rehabilitation exercises involved the elbow and the shoulder without external rotation. Clinical and x-ray follow-up data were available for all patients. Results: One patient was lost to follow-up two months after surgery: at this time the x-ray had demonstrated bone healing. Function could not be assessed as the fracture had occurred on the same side as the hemiplegia also caused by the initial trauma. For the fourteen other patients, mean follow-up was 12 months (range 6 – 36). Three patients operated via the median approach presented paraesthesia in the median nerve territory which was regressive in two. There were no neurological complications in the posteromedian approach group. Function was good for elbow and shoulder except for two patients. Bone healing was achieved in all cases. Discussion: These approaches allowed avoiding dissection of the radial nerve and provided a more aesthetic scar. Several difficulties were encountered with the median approach and reduction was difficult to control. In such cases it is advisable to widen the exposure to avoid stretching the median nerve. These approaches are contraindicated if radial nerve injury is identified preoperatively. Conclusion: Osteosynthesis of the humerus via a median approach avoids the need for radial nerve dissection. Reduction appears to be easier via the posteromedian approach with less risk than with the median approach


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 172 - 172
1 Sep 2012
Wirtz C Herold F Gerber Popp A
Full Access

OBJECTIVES. In elderly patients the temporary loss of function of the upper extremity due to immobilization for treatment of unstable proximal humeral fractures is a very disabling condition. Stable fixation of such fractures allowing immediate functional aftercare may contribute to early social reintegration in this group of patients. Aim of this study is to present the surgical technique of humeral blade plate fixation and the clinical and radiographic results after fixation of unstable surgical neck fractures with this implant followed by immediate functional treatment in patients older than 60 years. PATIENTS. 20 patients (4 male, 16 female) with a mean age of 74 years (59y–93y) were included in this study and treated consecutively for an unstable/displaced surgical neck fracture with a humeral blade plate. Postoperatively functional treatment was allowed. All but one patient had a clinical and radiographic follow-up 6 weeks po. At an average final follow-up of 18,8 months (12–24 months) 4 patients had died from causes unrelated to surgery. RESULTS. Surgery was performed in all patients without local or general complications despite comorbidities. In all patients anatomic reduction and stable fixation could be achieved. 6 weeks po all patients (N=20) were free of pain at rest, 7 patients had low pain (VAS < 4) when actively moving the arm. All patients used their operated arm for ADL and were back home or in the institution they came from at the time of trauma. All fractures were deamed to be healed without implant failure. In two cases a clinically asymptomatic 1–2mm protrusion of the blade through the subchondral bone was observed, but did not required further surgery. At final follow-up (N=8) the average absolute Constant/Murley Score was 68,6 points (contralateral 71,4). Radiographically all fractures had healed without complications. Implant removal was not required. CONCLUSION. Humeral blade plate fixation combined with suture tension-banding of the rotator cuff allows indirect reduction, dynamic and stable osteosynthesis of unstable surgical neck fractures even in osteoporotic bone. In our small series, this technique has shown to be a safe and reliable therapeutic option allowing immediate functional treatment and thus early social reintegration in elderly patients


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 213 - 213
1 Mar 2010
Quinlan J Sharafeldin K Corrigan J Kelly I
Full Access

Fractures of the proximal humerus account for 4–5% of all fractures with 80% requiring no surgical treatment. However, the management of the other 20% remains controversial. Multiple surgical modalities have been examined with no consensus as to which if any is the most effective. This study followed a series of 27 patients who had PHILOS plate fixation of their proximal humeral fractures. All patients were followed up clinically and radiologically for at least one year to a mean of 27.6+/−7.8 months. We reviewed 27 patients with a mean age of 62.2 years (16 patients were aged at least 60 years). The patients were classified as per the AO system into type A (n=11), type B (n=12) and type C (n=3) fractures. The mean DASH score was 51.8. The mean SF-36 scores for physical and social functions were 68.7 and 88.0 respectively. The mean Constant score was 50.5%. These results how that the PHILOS plate offers good functional outcomes across a spectrum of fracture severities and in an older population group. Its use should be considered where appropriate in the management of displaced proximal humeral fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 914 - 917
1 Nov 1993
Janes G Collopy D Price R Sikorski J

We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation. Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia. An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences outweigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 48 - 48
1 May 2012
Sidharthan S Jarvis A
Full Access

Lag screw fixation with plate osteosynthesis is the usual recommendation for oblique non-comminuted lateral malleolus fractures. Lag screw fixation may sometimes pose varying difficulties depending on the orientation of the fracture and in osteoporotic bones where the process may cause disintegration of the bone. The purpose of this study was to evaluate whether additional lag screw fixation with plate osteosynthesis offered any advantage over plate only fixation in non-comminuted oblique fractures of the lateral malleolus. A simple method of fixation was employed where the fracture was reduced and held temporarily with a K wire. After fixation with plate the K wire was removed. A total of 20 patients who had non-comminuted unstable oblique fractures of their lateral malleolus that had been surgically fixed plate only fixation were retrospectively evaluated. The patients were aged between 17 and 70 yrs. Evaluation of the success of fixation, complications, resultant mobility and patient satisfaction was based on information gathered from X-ray findings and clinic notes. These results were compared to an agematched group of 20 consecutive patients treated with lag screw fixation and plate osteosynthesis. There was no significant difference in the rate of or functional outcomes in either groups. Lag screw fixation offers no additional advantage when combined with plate synthesis of non-comminuted oblique lateral malleolus fractures


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 3
1 Mar 2002
Pritchard M Roberts B Bindra R
Full Access

The ‘Pi’ plate is an anatomical titanium plate recently introduced for the internal fixation of comminuted intra-articular distal radius fractures. We report our experience with this implant in a prospective series of twelve patients with an average age of thirty six years (range, 26–52 years). A dorsal approach with release of the EPL tendon and extra-compartmental exposure of the radius between the second and fourth extensor compartments was employed in all cases. Iliac bone graft and a styloid K-wire were used to augment the plate fixation. Post-operatively, active mobilisation was started after wound healing. Wrist motion and grip strength measurements were made at six weeks, three months and six months by the therapist. At six months, patients recovered an average of 85% of range of movement compared with the opposite wrist, except for palmar flexion (65%). No loss of reduction was observed on follow-up radiographs. Complications were compartment syndrome, intraoperative EPL rupture and two cases of extensor tendonitis requiring implant removal. The ‘Pi’ plate affords rigid fixation of distal radius fractures permitting early rehabilitation. It is however a demanding technique that is not without complications


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims. Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome. Methods. Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively. Results. A total of 138 patients underwent ADROM; 111 patients were available for long-term follow-up at a mean of 10.9 years (range 1 to 20). Mean age was 50.8 years (18 to 75);79 (57.2%) were female. Mean time from primary ORPF to ADROM was 11.9 months (6 to 19). Five patients developed superficial wound infection; ten developed symptomatic osteonecrosis/post-traumatic arthrosis (ON/PTA); four underwent revision arthrolysis. Median OSS improved from 17 (interquartile range (IQR) 12.0 to 22.0) preoperatively to 40.0 (IQR 31.5 to 48.0) postoperatively, and 39.0 (IQR 31.5 to 46.5) at long-term follow-up (p < 0.001). Median EQ-5D-3L improved from 0.079 (IQR -0.057 to 0.215) to 0.691 (IQR 0.441 to 0.941) postoperatively, and 0.701 (IQR 0.570 to 0.832) at long-term follow-up (p < 0.001). We found that aROM improved in all planes (p < 0.001). Among the variables assessed on multivariable analysis, a manual occupation, worsening Charlson Comorbidity Index and increasing socioeconomic deprivation were most consistently predictive of worse patient-reported outcome scores. Patients who subsequently developed ON/PTA reported significantly worse one-year and late OSS. Conclusion. ADROM in patients with persistent symptomatic stiffness following ORPF can achieve excellent short- and long-term outcomes. More deprived patients, those in a manual occupation, and those with worsening comorbidities have worse outcomes following ADROM. Cite this article: Bone Joint J 2022;104-B(1):157–167


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 81 - 81
1 Apr 2013
Suganuma S Tada K Segawa T Yamauchi D Tsuchiya H
Full Access

Introduction. The flexor carpi radialis (FCR) approach is widely used for volar plate fixation of distal radius fractures. However, patients sometimes complain of postoperative numbness at the thenar eminence. We propose this is derived from injury to the palmar cutaneous branch of the median nerve (PCBm). Materials and methods. From March 2010 to March 2012, we performed 10 operations of volar plate fixation for distal radius fractures using the FCR approach. We detected the PCBm intraoperatively and investigated the anatomy. Results. On average, the PCBm arises from the median nerve 44 mm proximal to the distal wrist crease. It arose from the radial side of the median nerve in nine cases and the ulnar side in one case. In all cases, it ran between the FCR and the palmaris longus tendon under the antebrachial fascia. Nerve supply to the FCR sheath was not observed in the field of operation. Discussion. Numerous studies report the necessity to preserve the PCBm during carpal tunnel release surgery, but the relationship between the FCR approach and the PCBm has not been emphasized. Our results generally agree with past reports on PCBm anatomy. In our experience, the FCR tendon should be retracted to the ulnar side to prevent PCBm injury. If the FCR tendon is retracted radially, the PCBm should be detected and retracted gently. Some studies report that the PCBm joins the FCR sheath at the level of the distal wrist crease. Thus, the distal sheath incision should not be extended blindly


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral femoral bowing angles were 10.5° (SD 5.7°)/6.1° (SD 6.2°). The postoperative mean anterior/lateral bowing values were changed by 8.7° (SD 5.4°)/4.6° (SD 5.9°). Bisphosphonates had been used contemporarily in 115 AFFs (78.2%) for a mean of 52.4 months (1 to 204; SD 45.5) preoperatively. Nailing was performed in 133 AFFs (90.5%), and union was obtained at a mean of 23.6 weeks (7 to 85). Delayed union occurred in 41 (27.9%), and nonunion occurred in 13 (8.8%). Contralateral AFF occurred in 79 patients (53.7%), and the use of a bisphosphonate significantly influenced the occurrence of contralateral AFFs (p = 0.019). Peri-implant fractures occurred in a total of 13 patients (8.8%), and a significant increase was observed in cases with plating (p = 0.021) and high grade of postoperative anterolateral bowing (p = 0.044). Conclusion. The use of a bisphosphonate was found to be a risk factor for contralateral AFF, and high-grade postoperative anterolateral bowing and plate fixation significantly increased the occurrence of peri-implant fractures. Long-term follow-up studies on the bilaterality of AFFs and peri-implant fractures are warranted. Cite this article: Bone Joint J 2021;103-B(11):1648–1655


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 182 - 182
1 Sep 2012
Khan L Wallace R Simpson A Robinson C
Full Access

Aims. The aim of this study was to compare biomechanical properties of pre-contoured plate fixation using different screw fixation modes in a mid-shaft clavicle fracture model. Methods. Fourth generation biomechanical clavicle sawbones with a mid-shaft osteotomy were plated in one of three modes: nonlocking bicortical, locking bicortical and locking unicortical mode. The specimens were then tested to failure in four-point bending and pull-off tests. Results. Failure due to fracture through the sawbone was more common in nonlocking bicortical mode while plate bending was more common in the locking bicortical group. The ultimate load at failure was significantly lower in the locking bicortical group compared to the nonlocking bicortical group, however there was no significant difference between the locking unicortical group and nonlocking bicortical group. In the pull-off tests 100% of nonlocking bicortical and locking bicortical plates failed by fracture of the sawbone. 100% of the locking unicortical plates failed by plate and screw pull-off from the sawbone. The load at failure was highest for the locking unicortical plate but this was not significantly different to the other groups. Conclusion. This study shows that specimens fixed with locking unicortical screw fixation withstood comparable or superior loads in four-point bending and pull-off test when compared to nonlocking bicortical and locking bicortical screw fixation. In addition both locking screws and unicortical screws appear to provide a protective effect against periprosthetic sawbone fracture. Locking unicortical screw fixation of pre-contoured plates may be a viable alternative in the fixation of mid-shaft clavicle fractures


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (. sd. 0.08) vs augmented 0.13 mm (. sd. 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (. sd. 0.02) vs augmented 0.15 mm (. sd. 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017). Cite this article: Bone Joint J 2013;95-B:1406–9


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 295 - 295
1 May 2006
Ramakrishnan M Shaw NJ
Full Access

Aim: To report the technique of reverse femoral LISS [Limited Invasive stabilisation system] plate fixation of pathological fractures of proximal femora with pre-existing deformity due to multiple fractures in a patient known to suffer with Osteopetrosis. Design: Osteopetrosis, a rare heterogeneous condition, is a result of failure of the bone remodelling. The orthopaedic presentations of which include, back pain, deformity of long bones and multiple fractures. Historically, most fractures in patients with Osteopetrosis were treated nonsurgically with good results, but at the expense of malunion. Operative treatment is indicated, to avoid disabling deformity or to treat nonunion of the fractures. The conventional onlay or inlay devices for fracture stabilisation are difficult to use due to malunion and obliteration of medullary canal, caused by previous fractures and hardness of the bone. The new LISS is an extramedullary, internal fixation system and its main features are an atraumatic insertion technique, minimal bone contact, and a locked, fixed-angle construction. The LISS plate can be used to stabilize the whole length of a femur with multiple deformities. Subject: A 46-year – old lady who is a known case of autosomal dominant Osteopetrosis sustained 5 left femoral and 4 right femoral pathological fractures, over a period of 25 years. They were treated nonoperatively and the fractures were healed with some malunion. During the recent clinical presentation, her bilateral proximal femoral fractures failed to unite by conservative methods and operative treatment was indicated. We used a bilateral reverse femoral LISS plate as the proximal fragments were short and needed axial and rotational control. Conclusion: The reverse LISS is a useful implant for treatment of femoral fractures, especially when the femur is deformed and the medullary cavity is obliterated as in cases of Osteopetrosis


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 279 - 280
1 Jul 2011
Slobogean G Bhandari M O’Brien PJ
Full Access

Purpose: To compare the functional outcome and quality-of-life following a displaced extra-articular proximal humerus fracture treated with open reduction and locking plate fixation versus non-operative management. To provide preliminary data for a subsequent prospective clinical trial. Method: Eligible subjects were identified through retrospective searches of a large emergency department admission database and the orthopaedic trauma database. All subjects ages . 3. 55 treated for a proximal humerus fracture between 2002 to 2005 were invited to participate. The Disabilities of Arm, Shoulder, and Hand (DASH), Health Utilities Index Mark 3 (HUI), Euroqol-5D (EQ-5D), and the SF-36 questionnaires were mailed to all eligible subjects. Initial radiographs were reviewed using the AO/OTA classification system. Only patients with A3, B1, B2, or B3 fractures were included. Results: Thiry-four subjects were included: 15 were treated with sling immobilization and 19 with locked plate ORIF. The non-operative group was approximately seven years older (mean age 74 versus 67, p = 0.046). DASH scores were similar between the groups: ORIF 26.6 ± 24 and Sling 26.5 ± 20. The 95% CI surrounding the 0.01 point difference (−16.0 to 15.9) slightly exceeds the 13 point cutoff for the instrument’s measurement error (minimal detectable change). Using univariable analysis, no statistically significant differences in health state values were detected. The mean HUI value for the ORIF group was 0.68 versus 0.75 for the sling (p=0.48). Mean EQ-5D values were 0.77 for the ORIF group and 0.80 for the sling group (p=0.73). The SF-36 PCS scores were also similar between the two groups: ORIF 41.1 versus Sling 39.8 (p=0.77). When controlling for age and pre-injury function, a 0.09 point difference in HUI values was detected favouring the sling treatment (p=0.036). No differences in DASH, EQ-5D, or SF-36 PCS scores were detected using regression models. Conclusion: The results of this small cohort suggest, for extra-articular fractures, the functional and quality of life outcomes may be similar between the two interventions. No trial comparing locked plate fixation and non-operative management has been reported. A total of 96 subjects will be needed for a prospective clinical trial comparing the two treatments (DASH difference 15, 80% power, 0.05 two-sided alpha)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 10 - 10
1 May 2012
Morris S Loveridge J Torrie A Smart D Baker R Ward A Chesser T
Full Access

There is controversy regarding the optimum method of stabilising traumatic anterior pelvic ring injuries. This study aimed to evaluate the role of pubic symphysis plating. Methods. All patients who underwent pubic symphysis plating in a regional pelvic and acetabular unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded. Results. Out of 178 consecutive patients, 159 (89%) were studied for a mean of 37.6 months. There were 121 males and 38 females (mean age 43 years). Symphysis pubic fixation was performed in 100 AO-OTA type B and 59 type C injuries using a Matta symphyseal plate (n=92), reconstruction plate (n=65), or DCP (n=2). Supplementary posterior pelvic fixation was performed in 102 patients. 5 patients required revision for failure of fixation or symptomatic instability of the pubic symphysis. A further 7 patients had metalwork removed for other reasons. Metalwork breakage occurred in 63 patients (40%). 62 of these 63 patients were asymptomatic and metalwork was left in situ. Conclusions. Plate fixation of the symphysis pubis is an effective method of stabilising anterior pelvic ring injuries with a low complication rate. There is a high rate of late metalwork breakage, but this is not clinically significant


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 315 - 315
1 May 2006
Amarasekera S Davey K
Full Access

To determine the outcome of Clavicle Hook Plate fixation in terms of level of function achieved, healing of the fracture and the need for removal of the hook plate. Review of patient records and radiographs of all the fractured clavicles and acromioclavicular dislocations that were surgically treated with a Clavicle Hook Plate. The study population was identified using the operating theatre data. A total of 24 patients (19 lateral third-Neer type II-fractures and 5 type III acromioclavicular dislocations) were treated from January 1998 to December 2003. Eighteen of the 24 plates (75%) had been removed at the time of the study. In 72% restriction of the range of movement and pain due to plate impingement were the main causes for removal of the plate. Two of the plates (11%) were removed due to ‘mechanical failure’; the plate being levered off the bone or eroding the acromion. Mechanical failure of the plate was significantly associated with an older age group (P=0.01). At the time of discharge from the clinic 57% had more than 50% of their shoulder movements, while 55.5% had minimal or no pain. We suggest that Clavicle Hook Plates should be routinely removed as they cause impingement symptoms and they be used with caution (if at all) in the older age group given the tendency for the plate to lever off the bone


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1385 - 1391
1 Oct 2018
Qvist AH Væsel MT Jensen CM Jensen SL

Aims

Recent studies of nonoperatively treated displaced midshaft clavicular fractures have shown a high incidence of nonunion and unsatisfactory functional outcome. Some studies have shown superior functional results and higher rates of healing following operative treatment. The aim of this study was to compare the outcome in these patients after nonoperative management with those treated with fixation.

Patients and Methods

In a multicentre, parallel randomized controlled trial, 146 adult patients with an acute displaced fracture of the midthird of the clavicle were randomized to either nonoperative treatment with a sling (71, 55 men and 16 women with a mean age of 39 years, 18 to 60) or fixation with a pre-contoured plate and locking screws (75, 64 men and 11 women with a mean age of 40 years, 18 to 60). Outcome was assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) Score, the Constant Score, and radiographical evidence of union. Patients were followed for one year.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 497 - 497
1 Nov 2011
Bel J Herzberg G
Full Access

Purpose of the study: Because of the difficulty of maintaining anatomic reconstruction, plate fixation is limited for complex fractures of the calcaneum. Implants with angular stability can broaden classical indications and improve outcome. Material and method: From February 2004 to February 2008 we treated 35 articular fractures of the calcaneum: 26 male, 6 female, 3 bilateral cases, mean age 41.46±15.99 years, age range 17–71, ≥ 3 displace fragments [Duparc IV:16; Duparc V: 16], preoperative CT [Sanders III: 22; IV: 13]. The surgical procedure was performed by one operator on days 4 to 7: lateral wide-L incision; articular and extra-articular reduction; lateral fixation using an AO-LCP. ®. plate with locking screws. Intra- and postoperative X-rays (Boehler angle, talo- and cubocalcaneal congruence), postoperative CT. Rehabilitation: mobilisation of the talocalcaneal joint on day 21; partial weight bearing after 2 months; complete weight bearing after 3 months. Radiological and clinical (Kitaoka) follow-up every 60 months. Results: Anatomic joint reduction was achieved and maintained by osteosynthesis (35/35). Late healing (smoking) (6/35). Healing: 2 months (21/35), 3 (14/35). Plate failure at 3 months without displacement (2/35). Anatomic joint reduction sustained ≥12 months (35/35). Gait without crutches after three months (35/35). Infection at 12 months (1/35). Mean follow-up (40 months, range 12–60). Discussion: The purpose of surgical treatment is to achieve anatomic reconstruction of all joint surfaces and restore calcaneal height, length, width and alignment until bone healing. Complex joint fractures with a high risk of loss of correction or secondary nonunion have limited the use of conventional reduction-osteo-synthesis methods in favour of first-line reconstruction-arthrodesis. These complex fractures require plates with multiple fixations to maintain stability. Optimal recover of function can be achieved if the anatomic reduction of the joint surface and extra-articular elements can be maintained stable from the start and sustained to healing, demonstrating the usefulness of reconstruction. No series has reported this innovating therapeutic concept. Conclusion: The reconstruction plate with locked screws enabled osteosynthesis of the most complex calcaneal joint fractures for which the discussion remains open concerning the role of osteosynthesis. The resistant fixation of all the fragments using screws with angular stability enabled stable reconstruction without loss of primary reduction, either secondarily or late, and allowed rapid rehabilitation. The long-term stability of the anatomic reconstruction guarantees good functional outcome which persists over time


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 219 - 219
1 May 2011
Sabnis B Ahmed I Chesney D
Full Access

Introduction: With an aging population, the number of hemiarthroplasties and Total Hip Replacements is on a rise. Though uncommon, one of the serious postoperative complications is periprosthetic fracture of femur. Dall Miles cable plate system is widely used for fixation of these fractures. Patient and Methods: We present a series of of 19 patients who underwent Dall Miles cable plate fixation for periprosthetic fracture over a hemiarthroplasty or a total hip replacement during the last 5 years, reporting clinical and radiological outcome measures. Results: Female to male ratio was 2:1. The average age was 77.33 (range from 55 to 93). Eight patients had the periprosthetic fracture after hemiarthroplasty while 11 had it after Total Hip Replacement. These two group were completely different in terms of their fitness, activities and expectations. Twelve were Vancouver B 1, 7 were Vancouver C. Five were initially managed with two plates, the remainder had one plate only. Patients were followed up at an average of 3.1 years (range 3.2 months to 5.1 years). Three patients had died at the time of our follow up due to unrelated medical problems. One patient had deep infection that required revision and 1 had superficial infection that healed with antibiotics. 1 patient underwent revision to a THR for hip pain. Of those managed with a single plate, 3 patients had plate/cable failure and underwent revision DM plating with 2 plates and cables along with allogenic bone grafting; all of these healed well. All of these patients had periprosthetic # following a THR. Five patients managed initially with 2 DM plates healed without any complications. Discussion: Even in this small series, we feel it is evident that Dall Miles plating using a single plate has a high incidence of plate failure (3 of 13). Orthogonal plating has been widely used in past for fixation of complex fractures and nonunions. We feel there is a distinct advantage of using two plates of uneven lengths to improve chances of healing, preventing implant failure and reducing stress riser effect. We advocate primary fixation of periprosthetic fractures of proximal femur over THR using 2 Dall Miles cable plates and bone graft. We would like to present our results and discuss this complex topic further


Introduction. To compare the union rates and post-operative mobility of antegrade intramedullary nailing of osteoporotic traumatic supracondylar femoral fractures (AO classification A to C2) with those of plating. Materials/Methods. We studied any traumatic intra or extra-articular supracondylar femoral fracture from 2005–2010. Patients were either admitted directly to our level 1 trauma centre or were referred from another hospital. Nineteen patients were identified, consisting of primarily fixation with five antegrade nails and fourteen plates. We defined osteoporotic bone as being present in anyone over sixty years old or who had a clinical diagnosis. One nail and six plates were excluded due to young age or fracture severity. This left four nails, six less invasive stabilisation system plates and two dynamic condylar screw plates. Both groups were comparable with respect to age, sex and AO fracture classification. Results. There was a significant difference in achieving union between the two groups (p=0.040). Union occurred within three months in all four fractures in the nail group but only three fractures (38%) united after primary fixation in the plate group. There were two failures due to screw pullout, one failure due to screw breakage, one broken plate after delayed-union and one screw breakage after non-union. The patients in the nail group had better mobility and less pain than the plate group but the difference was not statistically significant. Conclusion. We have shown that for patients with osteoporotic, supracondylar femoral fractures, fixation with an antegrade IM nail provides significantly better healing compared to plate fixation


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 179 - 180
1 Mar 2006
Pichon H Jager S Chergaoui A Carpentier E Chaussard C Jourdel F Saragaglia D
Full Access

Introduction: Previously, we noticed loss of initial reduction with conventional palmar plate osteosynthesis for dorsally displaced distal radius fractures. Locking Compression T plate may provide more stable fixation and we report our early experience. Materials and methods: Between November 2002 and April 2003, 23 patients (15 women, 8 men), mean age 55, (17–80) underwent open reduction and internal fixation using 3.5 mm locking compression oblique T plate (SYNTHES) through a Henry ‘s approach and a 2 weeks plaster cast immobilisation. All fractures were dorsally displaced. According to AO classification there were 15 A3 and 8 C1 and C2 fracture. 18 patients could be reviewed with a mean follow up of 16 months (6 to 30) Pre operatively, radial inclination was 11.7 ° (0–20), dorsal angulation 25.9 ° (8–48) and ulnar variance:4 mm (0–10). Results: Post-operatively, radial inclination was 23,2. ulnar variance: 1,2 mm and ventral angulation 4,6 °. At one year follow-up, there was no loss of post-operative reduction. According to SOFCOT ‘s criteria, there were 13 anatomical results and 5 moderate malunion. According to Green and O ‘Brien’s criteria, there were 9 excellent, 6 good, 3 fair and no poor results. Mean DASH score was 22.8 (5.8 – 62.5). Strengh and pinch were respectively 95 % and 91 % when compared with the opposite side. There were 6 complications concerning 4 reflex sympathetic dystrophy, one carpal tunnel syndrome and one hypertrophic scar. Discussion: In our experience, classic palmar plate fixation showed inability for maintaining reduction during time. Locking Compression 3,5 T plate by a palmar approach which is a demanding technique, avoids loss of post-operative recution. Conclusion Locking Compression 3.5 T Plate by palmar approach is an effective treatment for dorsally displaced distal radius fracture but the plate itself and ancillary tools have to be improved to reduce operatively difficulty


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 622 - 623
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 18 - 18
1 May 2018
Williamson M Iliopoulos E Jain A Ebied W Trompeter A
Full Access

Background. There exists no consensus opinion as to the most suitable post-operative rehabilitation and weight bearing status for proximal tibia articular fractures treated with internal fixation using plates and screws. Objectives. The aim of this study is to investigate whether the post-operative weight bearing status is associated with loss of reduction and articular collapse. Study Design and Methods. Data was retrospectively analysed from our prospective database in a major trauma centre. Group I were non-weight bearing for the first six weeks post-operation and Group II were instructed to weight bear fully immediately post-operation. Radiographs were taken day one post-operation, at six weeks and at three months and analysed for fracture displacement and joint depression or loss of fixation. Results. 90 patients were included in the study. The follow up radiographs demonstrated no failure of fixation in either study group. One patient from the weight bearing group had >1mm joint depression (4mm) identified at the first follow up, which did not worsen by the second. Conclusions. This study shows immediate post-operative full weight bearing does not affect the fixation or cause articular collapse up to three months after surgery. We propose that patients should be encouraged to weight bear immediately post-operation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 215 - 215
1 May 2011
Kosy J Giles N
Full Access

The Proximal Humeral Internal Locking System (PHILOS) is being used increasingly in the treatment of proximal humeral fractures. Improvements in operative technique since its first use may represent improved functional results. We analysed 28 cases performed in the two years following October 2006. There were 22 females and 6 males. Mean age was 65 years (Range 37–79 years). There were five 2-part, nineteen 3-part, and four 4-part fractures. Functional results were measured using the Oxford Shoulder Score, American Shoulder and Elbow Surgeons’ Score (ASES) and Constant Score (Age and sex matched). This provided objective and subjective scores of function after a mean follow-up period of 15 months (Range 3–27 months). These results were compared to the patient’s non-operated shoulder to determine loss in function.

Following PHILOS fixation, function of the operated arm was decreased both subjective and objective scoring. This change was significant for all three scores (p-values < 0.01). Sub-analysis comparing patients aged < 60 years with those > 60 years and 2-part fractures with 3- and 4-part fractures showed no significant difference.

We conclude that our results show that function in the operated arm is lost. Our data confirms previously published function scores and shows no impact of the patient’s age and fracture configuration on the results of this implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 618 - 620
1 Aug 1973
Sharp IK

1. A technique for internal fixation of the disrupted symphysis pubis by an angled four-hole plate is described.

2. In five patients in whom internal fixation was used rapid relief of the severe discomfort caused by symphysial disruption was noted.


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 2 | Pages 258 - 271
1 May 1971
Burwell HN

1. One hundred and eighty-one fractures of the tibial shaft were treated by rigid fixation using conventional plates.

2. Comparison is made with series of fractures treated by the closed method.

3. The incidence of non-union, or delayed union requiring a long period of plaster immobilisation, was found to be less with the open method of treatment.

4. Plating was also found to give better functional results with a shorter period of disability except in severe open fractures.

5. Plating is a valuable method of treatment for tibial fractures in the elderly.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 270 - 270
1 Mar 2013
Moon J Hong J Kwon H
Full Access

Backgrounds

The rigid fixation of glenoid base plate is essential for the prevention of dissociation of the construct in the reverse total shoulder arthroplasty. For the rigid fixation, ideal placement of fixation screw is crucial but it is difficult to determine the best direction and length of screws. The purpose of this study was to determine configuration of optimal screw in cadaveric scapulae and compare with that in patient who underwent reverse total shoulder arthroplasty.

Materials and methods

Seven scapulae were used and implanted using a variable angle base plate with four directions screws. Optimal screw placement was defined as that which maximized screw length, accomplished far cortical purchase. Insertion angle and length of every screw was measured from AP and axial radiograph taken after the screws fixation. In a similar manner, the insertion angles of screws were measured from radiographs of 7 postoperative patients who underwent reverse total shoulder arthroplasty. The averages of length and insertion angle of 4 screws from two groups were compared.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 43 - 43
1 Jun 2023
Das A

This edition of Cochrane Corner looks at some of the work published by the Cochrane Collaboration, covering interventions for treating distal femur fractures in adults; ultrasound and shockwave therapy for acute fractures in adults; and local corticosteroid injection versus placebo for carpal tunnel syndrome.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 162 - 162
1 May 2011
Aksu N Aslan O Gogus A Kara A Isiklar Z
Full Access

Purpose of the Study: We evaluated the complications of proximal humeral fractures, which are treated with locked plates.

Materials and Methods: 103 patients (70 female, 33 male) with proximal humeral fractures with an average follow-up time of 19 months (2 weeks– 43 months) and an average 62,1 (21–90) years of age are treated with open reduction and internal fixation from September 2005 to April 2009 in our clinic. Internal fixation was performed with PHILOS plate in 93 patients and S3 Humeral plate in 10 patients. Early and late complications that are encountered during the follow-up time is presented.

Results: Complications occurred in 10 patients (7 females, 3 males) with an average age of 67,1 (41–89) years from which 5 of them had varus inclination, 5 had inter-joint screw penetration, 1 had fixation failure, 1 had breakage of the implant and 1 had infection. Complication rate (10 of the 103 patients) was 9.7%. The rates of varus inclination (5 of the 103 patients) and the rates of screw penetration (5 out of 103) were both 4.85%. During the follow-up time 3 of the 5 patients with varus inclination (60%) had progression (displacement of varus). 4 of the 5 patients with varus inclination (80%) had screw penetration. All of the 4 patients (100%) with varus displacement had screw penetration. The average Constant Murley shoulder score of the complication group were 67.8 (50–90).

Conclusion: Surgical treatment of the proximal humeral fractures has a high rate of complications. Screw penetration rates of the patients with varus inclination is 60%. Accurate indication, protection of the head’s inclination angle with an appropriate surgical approach and a proper technique, fine calculation of the screw lengths are needed for a successful functional result. In our study, where we have found fewer rates of complications than the literature, we have pointed out the reasons of the complications and we have stated the noteworthy precautions to lower the rates of these


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 49 - 49
1 Jan 2011
Kosy J Giles N
Full Access

The Proximal Humeral Internal Locking System (PHILOS) is being used increasingly in the treatment of proximal humeral fractures. Improvements in operative technique since its first use may represent improved functional results.

We analysed 28 cases performed in the two years following October 2006. There were 22 females and 6 males. Mean age was 65 years (Range 37–79 years). There were five 2-part, nineteen 3-part, and four 4-part fractures. Functional results were measured using the Oxford Shoulder Score, American Shoulder and Elbow Surgeons’ Score (ASES) and Constant Score (Age and sex matched). These results were compared to the patient’s non-operated shoulder to determine loss in function.

Following PHILOS fixation, the Oxford Score increased by a mean of 11 points, the ASES decreased by a mean of 25 points, and the Constant Score decreased by a mean of 31. This change was significant for all three scores (p-values < 0.01). Sub-analysis comparing patients aged < 60 years with those > 60 years and 2-part fractures with 3- and 4-part fractures showed no significant difference.

We conclude that our results confirm previously published functional data and show the patient’s age, and fracture configuration, have no impact on the results of this implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 599 - 601
1 Aug 1989
Yamano Y

The design and use of a prong plate for the treatment of displaced fractures of the femoral neck is described. The prongs hold the femoral head, and the plate is screwed to the anterior cortex of the femoral neck and trochanteric region. The new plate has been used in 32 patients with Garden stage III or IV fractures and 29 had a good result. Bony union was seen within 11 weeks in all patients in whom bleeding of the femoral head was noted at operation, but was much delayed in patients without bleeding. Late segmental aseptic necrosis was seen in four patients after follow-up of at least two years, and successfully treated. The prong plate allows accurate reduction, impaction and strong rigid fixation with less disturbance of the intramedullary blood flow than other fixation methods.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2009
Baker P Akra G Eardley W Candal-Couto J Liow R Rangan A
Full Access

Introduction: The surgical management of proximal humeral fractures continues to be an unsolved problem for the orthopaedic surgeon. Disagreement remains over how best to fix the more challenging complex fractures in younger patients where the ultimate goals of treatment are restoration of a painless shoulder, adequate function, and preservation of humeral head viability.

The PHILOS plate attempts to improve on previously designed implants by preserving the biological integrity of the humeral head articular fragment. The minimally invasive technique minimises soft tissue damage whilst at the same time securing the reduction using multiple locking screws with angular stability, thus allowing early mobilisation.

Methods: Retrospective review of the notes and x-ray images of 54 fractures treated with the PHILOS plate between Jan 2000 and Aug 2005. Data including baseline demographics, the presence of any complications and the need for reoperation were collected. In addition 43 (81%) patients were contacted and Oxford (OSS) and Disabilities of the Arm, Shoulder and Hand (DASH) scores were calculated to assess functional recovery. All patients were contacted at a minimum of 6 months following fixation with an average follow up of 18 months (Range 6–41 months)

We also present a cost analysis relating to the use of the PHILOS plate in practice.

Results: 54 fractures in 53 patients (25F:28M). Average age 54.4. There were 26 2-part, 15 3-part and 13 4-part fractures. A total of 11 (20%) patients had complications of which 7 (13%) required reoperation. These complications included deep infection (3 cases), AVN (4), Non Union (3) and plate impingement (1).

Mean OSS and DASH at follow up were 24.8 (S.D 11.6) and 28.0 (S.D 26.9) respectively. Worse scores were seen in those patients who had complications (OSS 39.4 Vs 22.6, DASH 58.2 Vs 23.4) although this difference was not statistically significant. There was also a trend for poorer scores with increasing fracture complexity and better scores in those patients operated upon by surgeons with a specific interest in the upper limb and in patients whose surgeon had performed more than 5 fixations.

Conclusion: Our series reports a much higher complication rate (20%) than that previously published. Whilst those patients who do not suffer complications reported good functional outcomes the presence of postoperative complications was associated with poorer results. Outcomes following surgery were affected by patient, implant and surgeon related factors. Given the high rate of serious complications and their detrimental affect on outcome surgeons should give serious consideration to the appropriateness of using such implants. To clarify these issues, further prospective randomised trials are needed.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 9 - 9
1 Mar 2009
Rajkumar S Nagarajah K Moiz M
Full Access

OBJECTIVES: To review the short-term functional results of the surgical treatment of tibial plateau fractures using low profile peri-articular plates.

METHODS: Forty-nine displaced fractures of the tibial plateau in forty-nine patients were treated with open reduction and buttress plate fixation using low profile plate between 2002–2006. All aspects of their care, including tibial plateau fracture type, operative management and associated injuries, were documented. Preoperative and postoperative follow-up radiographs were analyzed for fracture classification and adequacy of reduction. All patients were followed up with clinical assessment and given Iowa knee functional outcome questionnaires. Data were also collected regarding return to work and sporting activities. The average age of the patients was thirty-eight years and the mean follow-up was 25 months, with a range of 12 to 52 months.. Of the forty-nine fractures studied, twenty-six were classified as Schatzker types I, II, or III, and the remaining twenty-three were types IV, V, or VI. Forty-six patients had closed injury while three had open fractures.

RESULTS: 48 of the fractures healed without additional surgical intervention or bone grafting except for one bicondylar fracture which needed amputation because of deep infection and soft tissue problem. Thirty eight patients had follow-up of greater than 1 year. The average time to radiographic callus was 6.2 weeks, and the average time to complete union was 16 weeks. The articular step-off average was 0.8 mm, with a range of 0 to 5 mm. The range of motion of the knee averaged 3° of extension to 120° flexion, which was an average of 87% of the total arc of the contralateral knee. The average Iowa Knee Score was 88 points (range, 72 to 100 points). The postoperative alignment demonstrated 1 patient with a malalignment of 4 degrees procurvatum and 1 patient with 3 degrees of valgus. There were two superficial wound infections and one case of deep infection.

CONCLUSIONS: Open reduction and internal fixation is a satisfactory technique for the treatment of displaced fractures of the tibial plateau, particularly for patients younger than fifty years. The use of low profile tibial plates appears to stabilize complex fractures of the tibial plateau with a low incidence of complications. The low profile plate functioned well in maintaining alignment and obtaining union in these high-energy fractures.


Bone & Joint 360
Vol. 11, Issue 2 | Pages 37 - 41
1 Apr 2022


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 331 - 331
1 Mar 2004
Redfern D Syed S Davies S
Full Access

Introduction: Unstable fractures of the distal tibia that are not suitable for intramedullary nailing are commonly treated by open reduction and internal þxation and/or external þxation techniques. Treatment of these injuries using minimally invasive plate osteosynthesis (MIPO) techniques may offer the advantage of achieving adequate þxation whilst minimising soft tissue injury and damage to the vascular integrity of the fracture fragments. Purpose: We report our experience using MIPO techniques for the treatment of unstable fractures of the distal tibia. Method: A review of all patients who sustained an unstable fracture of the distal tibia treated by MIPO between 1998 and 2001 was undertaken. Twenty patients were identiþed. The mean age was 38.3 years (17 Ð 71). All fractures were closed, and were classiþed according to the AO system. Intra-articular fracture extensions were classiþed according to RŸedi and Allgšwer. Results: Sixty percent of patients achieved callus by 8 weeks. All patients achieved callus by 3 months. The mean time to full weight bearing was 12 weeks (8 Ð 17). By 6 months 18/20 patients had achieved union. The two remaining patients achieved union by 7 months without further surgery. There were no deep infections and only one malunion. There were no cases of failure of þxation. Conclusion: MIPO appears to offer a reliable method of þxation of fractures of the distal tibia that are unsuitable for intramedullary nailing. Our results suggest that this technique is associated with a lower risk of signiþcant complications than encountered with more traditional methods of þxation of such fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 404 - 425
1 Aug 1964
Nevile Burwell H Charnley AD

1. A simple method of internal fixation of adult forearm fractures which gives consistent good results is necessary because the closed method of treatment is of limited application.

2. Open reduction of fractures without rigid internal fixation gives a high proportion of non-union and poor results.

3. Rigid internal fixation with standard plates and screws has been shown to give a low incidence of non-union in this series.

4. A three and a half inch long plate with six screws is suitable for most fractures, but if there is moderate or severe comminution, or if there is a segmental fracture, longer plates and more screws should be used to provide sound fixation.

5. Severely comminuted fractures with large avascular bone fragments should have the addition of a bone graft at the time of the plating operation in order that union may be assured. Thin strips of iliac bone are preferred.

6. Rigid plating is considered to be the most satisfactory treatment for open fractures.

7. Immobilisation of the limb after operation is not necessary and is undesirable if the fixation is rigid.

8. The functional results of this treatment are good and seemingly better than those achieved by other methods.

9. Serious complications of the plating operation are few and avoidable.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 85 - 85
1 Jan 2017
Edwards T Patel B Brandford-White H Banfield D Thayaparan A Woods D
Full Access

Clavicular hook plates have been used over the last decade in the treatment of lateral clavicular fractures with good rates of union reported throughout the literature. Fewer studies have reported the functional outcome of these patients and some have reported potential soft tissue damage post plate removal. We aimed to review the functional outcomes alongside union rates in patients treated with hook plates for lateral clavicular fractures.

In this retrospective case series, 21 patients with traumatic lateral third clavicular fractures were included. 15 had Neer type II fractures, 4 Neer type III fractures, 1 patient had a Neer type I fracture and 1 radiograph was not able to be classified. All patients were treated with clavicular hook plates at the same district general hospital by five experienced surgeons between March 2010 and February 2015 adhering to the same surgical protocol. All patients had standard physiotherapy and post operative follow up. Plates were removed when radiological union was achieved in all but one patient who had the plate removed before union was achieved due to prolonged non-union. Patients were followed up post plate removal and evaluated clinically using the Oxford Shoulder Score. Their post plate radiographs were assessed by an independent radiologist and bony union documented.

21 patients were included. Mean age was 40 (range 14–63) with a male:female ratio of 17:4. Mean follow up was 5 months post injury (1–26 months). The hook plate remained in situ for a mean time of 4.3 months (2–16 months). One patient developed a post-operative wound infection treated with antibiotics, 2 patients developed adhesive capsulitis, one patient had not achieved bony union prior to hook plate removal at 16 months, however did achieve union 2 months post plate removal, two patients required revision plating. All patients achieved bony union eventually with good alignment and no displacement of the acromioclavicular joint seen on the most recent post operative radiographs. Post plate removal Oxford Shoulder Scores indicated good shoulder function with a mean score of 41.5 (maximum score possible 48 and the range of scores for our cohort was 30–47).

Our data would support the use of hook plates in the treatment of lateral clavicular fractures. All patients achieved union eventually with good alignment and this was reflected in the good functional outcome scores. This study is limited in its small cohort and short-term follow up. More research is required to examine the long term consequences of hook plate surgery in a larger patient population.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 6 - 6
1 Jan 2016
Madadi F
Full Access

High tibial osteotomy generally helps patients to postpone the TKA or even stay in peace for rest of their life, but sometimes these procedures enhance the process of osteoarthritis (1) several reasons like unhealthy lateral compartment of the knee or age or weight or concomitant debilitating diseases could be included in account.

In this study we focused on those patients that were selected properly with correct procedure but still shows the knee OA enhancement.

Hypothesis: probably bone bruise around the site of osteotomy as trauma of surgery can make a bad condition.

As a RCT study between 2 groups with different technique of osteotomy especially the distance of osteotomy site from the joint line of proximal tibia was our main reason to choose the different procedures.

We did a randomized clinical trial with not more than a year follow up and mostly emphasis in geometry of bone bruise around osteotomy site.

Group A: 50 knees, open wedge and plate technique.

Group B: reversed-v MIS the same 50 other knees (FM)

Method: All patient asked for MRI before and in 1st 10 days post surgery from their target knees.

Those with positive bone bruise sign before surgery were excluded. In post op MRIs we measured the geometry of bone bruise.

1- Our finding shows upward-downward length of bone bruise in MIS (F.M) reversed-v = 14–40 mm and in open wedge = 14–37 mm

Depth (Medial-lateral) and AP diameter almost the same.

2- To omit the bias of bone bruise around the open wedge technique we ignored this part.

Result and conclusion:

Group A: had 14 – 40 mm bone bruise that in 61% reached to sub chondral bone (distance of osteotomy's site from sub chondral bone).

Area was (17−4mm).

Group B: because of the distance of osteotomy site from joint line were 60–70 mm. in no one bone bruise was closer than 26mm to sub chondral bone.

So, our Iatrogenic bone bruise from joint line in reversed - v is in safer zone than open wedge and plating with p. value of 0.0001.

In future we need to follow our patients to be sure if bone bruise makes any hazard for the knees.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 348 - 348
1 Mar 2004
Ashwood N Cobb J Robbins G Blunn G
Full Access

Massive cemented endoprosthesis are used to enable early resumption of activity after tumour surgery. The longevity of the prosthesis varies with anatomical site, pros-thesis type, and mode of þxation. Revision surgery will be required in approximately 50% of cases of endopros-thetic replacements around the knee by 10 years because of aseptic loosening. Insertion of a second cemented endoprosthesis is a challenge because of the poor quality of the remaining bone and loosening recurs quickly. The use of extracortical plate þxation in joint sparing surgery where the remaining bone after tumour resection will not accept an intramedullary stem is also described.

The þrst series of 14 patients with extracortical plate þxation in difþcult revision or joint-sparing tumour surgery with a mean follow-up of 5 years are described. The three-plate design incorporates well within a remodelled cortex to achieve osseomechanical integration with all patients regaining their premorbid level of function within 5 months. At 5 years the Enneking scores averaged 27.3.

One revision was required in a femoral replacement because of loosening. It was possible to insert a new endo-prosthesis as the intramedullary bone had reconstituted.

The preliminary results suggest that this technique may provide an easy, biomechanically friendly alternative to a device with an intramedullary stem, which has a shorter lifespan in revision tumour surgery.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 221 - 221
1 Mar 2003
Katonis P Muffoletto A Papadopoulos C Thalassinos I Hohlidakis S Hadjipavlou A
Full Access

Aim: Of Calveston (USA) and Crete (HELLAS). We studied immediate and long-term outcome of 50 patients who underwent subaxial lateral mass fixation of the cervical spine between January 1997 and March 2001.

Patients and Methods: Intraopeartive fluoroscopy and somatosensory evoked potential monitoring were employed in all patients. Immediate postoperative CT scans were performed to determine screw trajectory and placement. Follow up ranged from 1 to 5 years.

Results: Postoperative CT scans showed that 113 of 210 screws (54%) had unicorticate and 46% had bicorticate purchase. Forty-five screws (31 %) had suboptimal trajectory, but only 7 of these screws minimally penetrated the foramen transversarium without resultant vascular or neurological sequelae.

The overall fusion success rate in our series was 90%, while pseudoarthrosis occurred in 5 patients (10%), with screw breakage in 1 patient (2%). Two of these patients had bone graft supplementation and in other 2 patients was done anterior fusion.

Conclusions: Results of this study show that the recommended drilling technique and trajectory (15–25 degrees postal to the sagital plane, 20–30 degrees lateral I the axial plane), supplemented bone grafting and intraoperative SEP monitoring are all associated to good screw placement, fusion and neurological outcome and are recommended for all lateral mass fusion procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee.

In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 141 - 143
1 Feb 1968
Fordyce A


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 6 - 6
1 Nov 2015
Griffiths J Taheri A Day R Yates P
Full Access

Periprosthetic femoral fractures are a challenging problem to manage. In the literature various constructs have been designed and tested, most requiring cables for proximal fixation. The Synthes Locking Attachment Plate (LAP) has been designed to achieve proximal fixation without the use of cables.

The aim of this study was to biomechanically evaluate the LAP construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty (THA).

Twelve synthetic femora were tested in axial compression, lateral bending and torsion to determine initial stiffness, and stiffness following fixation of a simulated midshaft fracture with and without a bone gap. Two different fracture fixation constructs (six per group) were assessed. Each construct incorporated a broad curved LCP with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bicortical locking screws. Axial, lateral bending and torsional stiffness were assessed using intact specimen values as a baseline. Axial load to failure was also measured. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (simulating a comminuted fracture) (p=0.01). There were no significant differences between the two constructs in any of the other modalities tested. Loading to failure resulted in no significant differences between constructs, in either initial stiffness or peak load.

In conclusion the LAP construct enables bi-cortical screw fixation around a prosthesis. Compared to cables, this was stiffer when there was a bone gap and thus should offer improved proximal fixation of Vancouver B1 proximal femoral fractures in cemented THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 7 - 7
1 Jul 2014
Bansal M Shetty S Phillips S Groom A
Full Access

The purpose of this study is to describe the use of the PHILOS plate (Synthes) in reverse configuration to treat complex distal humeral non-unions.

Non-union is a frequent complication of distal humeral fracture. It is a challenging problem due to the complex anatomy of the distal humerus, small distal fragment heavily loaded by the forearm acting as a long lever arm with powerful forces increasing the chances of displacement. Rigid fixation and stability with a device of high “pull-out” strength is required. The PHILOS plate has been used in reverse configuration to achieve good fixation while allowing central posterior placement of the implant.

11 patients with established non-union of distal humeral fractures were included in this study. No patient in whom this implant was used has been excluded. Initial fixation was revised using the PHILOS plate in reverse configuration and good fixation was achieved. Bone graft substitutes were used in all cases. Patients were followed to bony union, and functional recovery.

All fractures united. One required revision of plate due to fatigue failure. Average time to union was 8 months with excellent restoration of elbow function.

A reversed PHILOS plate provides an excellent method of fixation in distal humeral non-union, often complicated by distorted anatomy and previous surgical intervention. It has a high “pull-out” strength and may be placed in the centre of the posterior humerus, allowing proximal extension of the fixation as far as is required. It provides secure distal fixation without impinging on the olecranon fossa. It is more versatile and easier to use than available pre contoured plating systems.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 340 - 340
1 Mar 2004
Rooney B Chan P Hems T
Full Access

Aims: The results of open reduction and internal þxation of 24 unstable dorsally displaced fractures of the distal radius are reported. Methods: The fractures occurred in 24 patients (mean age 39) and 17 of these fractures were AO Type C. All fractures were treated with open reduction and subperiosteal placement of dorsal 2.0mm or 2.7mm AO mini-fragment plates between 1st and 2nd dorsal compartments and below the 4th compartment. Additional volar plate þxation was required in 6 cases. Patients were examined and X-rays performed. Outcome was assessed using the Modiþed Mayo Wrist Score and Patient Evaluation Measure. Results: At þnal follow-up (mean 36 months), the mean range of movement of the wrist was: extension 78¡, ßexion 64¡, pronation 82¡ and supination 83¡. Grip strength averaged 84% of the unaffected side. Radiographic assessment showed a mean volar angle of 8¡, articular step in 5 cases and evidence of osteoarthritis in 10 wrists.

The þnal outcome, using the Modiþed Mayo Wrist Score was excellent in 13 cases, good in 7, and fair in 4 cases. Complications were seen in 3 patients and metalwork has subsequently been removed in 7 patients for tendon irritation but there have been no cases of extensor tendon rupture. Conclusions: This initial experience has encouraged the use of open reduction and dorsal plating as the treatment of choice in young patients with unstable and/or intra-articular fractures of the distal radius. With time, range of movement and grip strength, continue to improve.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1646 - 1647
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 499 - 499
1 Aug 2008
Hulse N Jain P Basappa P Reddy G Hadidi H
Full Access

Materials and Methods: Consecutive 39 patients who underwent first metatarsophalangeal joint (MTPJ) arthrodesis for hallux rigidus were assessed clinically, radiographically and functionally at a mean follow up of 21.45 months. Clinical assessment was performed by two blinded assessors in a specially arranged research clinic. Radiological examinations were performed separately by two independent researchers on digitalised weight bearing radiographs. Functional outcome was assessed using American Orthopaedic Foot and Ankle Society (AOFAS) hallux score and a short form-12 (SF-12) questionnaire.

Results: There were 19 patients who had dorsal contoured titanium plates and 20 patients who had single inter fragmentary screw fixation. Both the groups were comparable preoperatively. All except 5 patients achieved radiological fusion at a mean of 7.64 weeks. Over all rate of fusion in the present series is 87.1%. There were 4 non-unions in the plate group and one in screw group. Mean AOFAS score was 74.94 in the screw group and 70.63 in the plate group. There were no hardware problems in the single screw group. However in the plate group one patient with non-union broke the plate and another patient had back out of screws. There were no statistically significant differences in terms of pain-relief, activity-limitation, cosmetic appearance, foot wear requirements, dorsiflexion angle, hallux-valgus angle and inclination angles and SF 12 scores. Four patients in the plate group and one in screw group were unsatisfied with the surgery.

Conclusions: Solid fusion has resulted in good pain relief and patient satisfaction in both groups. In the dorsal plate group 4 patients (21.6%) had non-unions, two patients had metal problems. We have stopped using the plate alone technique for the fixation of first MTPJ fusion.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant.

Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement.

Cite this article: Bone Joint J 2013;95-B:396–400.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 136 - 136
1 Sep 2012
Munro C Baliga S Johnstone A Carnegie C
Full Access

Volar Locking Plates (VLP) have revolutionised the treatment of distal radius fractures allowing the anatomic reduction and stable fixation of the more comminuted and unstable of fractures. The benefits of this in terms of range of movement (ROM), pain and earlier return to work and daily activities is documented. However we were interested in was what improvements in wrist function patients made from 6 to 12 months after injury?

Methods

We retrospectively looked at a series of 34 consecutive patients that had undergone VLP fixation through a standard anterior approach followed by early physiotherapy. We documented standard demographics and assessed function in terms of Range of Movement, Grip strength (GS), Modified Gartland and Werley score (MGWS), Patient Rated Wrist Evaluation (PRWE) and the quick DASH questionnaire at six and twelve months

Results

Two patients were excluded from analysis as they failed to make both assessments. Of the 32 remaining (26 female:6 male) the mean age was 53.2yrs; range (26–78). On average GS, PGS, VAS function and pain did not improve. There was a modest improvement in Movement; Wrist Flexon-13 deg, Wrist Extension-14deg, Radial Deviation-7deg, Ulnar Deviation-9deg. There was no improvement in pronation and supination.

There was little improvement in qDASH, PRWE and mGW Scores with only a mean 1.8, 5.6 and 3.6 point improvement respectively.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 501 - 501
1 Nov 2011
Riouallon G Odent T Topouchian V Finidori G Padovani J Glorion C
Full Access

Purpose of the study: Data are scarce on the long-term outcome after anterior spinal fusion for idiopathic scoliosis in adolescents. The purpose of this study was to assess the clinical and radiological results obtained in a monocentric series using a single-phase fusion with pre-formed plates for the treatment of lumbar, thoracolum-bar and thoracic idiopathic scoliosis in adolescents.

Material and method: This procedure was performed in 111 patients from 1975 to 1993. Complete clinical and radiological evaluations were available for 35 patients, 7 male and 28 female. The SRS-30 questionnaire (translated into French by the authors) and the Oswestry score were used to assess functional outcome. Radiographic data were collected by an independent observer who read the pre-, post- and last follow-up images. Full spine images were available to assess correction of the curvature, frontal and sagittal balance, pelvic parameters, and degenerative changes in the subjacent discs. Functional outcome was assessed in relation to the radiographic findings.

Results: Mean follow-up was 22 years (range 16–31). Mean age at surgery was 14.5 years. At last follow-up, none of the patients were unemployed because of a spinal problem and 21 women had had one or more successful pregnancies. The mean SRS-30 score was 3.8/5 and correlated with the Oswestry score (13.8%). One patient underwent revision for disc herniation and one for posterolateral lumbosacral fusion because of persistent frontal imbalance. There as a fracture of the proximal screw in six patients with no sign of nonunion. At last follow-up, the mean Cobb angle was 14 (0–42). Frontal imbalance was noted in 18 patients, mean 12 mm. In the sagittal plane, three patients presented anterior imbalance. The pelvic parameters were within the range of the general population. Signs of L5-S1 disc degeneration were noted in ten patients, with no correlation with functional outcome.

Conclusion: Anterior fusion gives good long-term functional results in the treatment of idiopathic scoliosis in adolescents. Patients can pursue a normal occupational and familial life. This technique has provided satisfactory correction in the frontal and sagittal planes.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 18 - 18
1 Mar 2005
Schepers A van der Jagt D
Full Access

In June 1999 we instituted a prospective, randomised, double blind study to determine whether in the use of the Profix® total knee replacement system the addition of screws improved the fixation of the tibial base plate. There were 145 arthroplasties in 137 patients, 77% of them female. Their mean age was 66 years. In 86% of the patients there was osteoarthritis and in 14% an inflammatory arthritis. On a random basis, supplementary screws were inserted through the base plate into the tibia in 49% of arthroplasties and the remaining 51% were not fixed. In both groups the postoperative femoral angle measured 95% and at 12-month evaluation the tibial angle measured 89°, giving a total valgus angle of 6°. To date no tibial base plates have come loose. It is felt that the large central titanium peg plays a major role in assisting fixation of the base plate to the tibia and that supplementary screws are unnecessary. There is a small cost saving when screws are not used. We postulate that one may in the future minimise polyethylene debris tracking and osteolysis.