REVIEW OF FUNCTIONAL OUTCOMES AND UNION RATES IN PATIENTS WITH LATERAL CLAVICULAR FRACTURES TREATED WITH HOOK PLATE FIXATION

European Orthopaedic Research Society (EORS) 2016, 24th Annual Meeting, 14–16 September 2016. Part 1.



Abstract

Clavicular hook plates have been used over the last decade in the treatment of lateral clavicular fractures with good rates of union reported throughout the literature. Fewer studies have reported the functional outcome of these patients and some have reported potential soft tissue damage post plate removal. We aimed to review the functional outcomes alongside union rates in patients treated with hook plates for lateral clavicular fractures.

In this retrospective case series, 21 patients with traumatic lateral third clavicular fractures were included. 15 had Neer type II fractures, 4 Neer type III fractures, 1 patient had a Neer type I fracture and 1 radiograph was not able to be classified. All patients were treated with clavicular hook plates at the same district general hospital by five experienced surgeons between March 2010 and February 2015 adhering to the same surgical protocol. All patients had standard physiotherapy and post operative follow up. Plates were removed when radiological union was achieved in all but one patient who had the plate removed before union was achieved due to prolonged non-union. Patients were followed up post plate removal and evaluated clinically using the Oxford Shoulder Score. Their post plate radiographs were assessed by an independent radiologist and bony union documented.

21 patients were included. Mean age was 40 (range 14–63) with a male:female ratio of 17:4. Mean follow up was 5 months post injury (1–26 months). The hook plate remained in situ for a mean time of 4.3 months (2–16 months). One patient developed a post-operative wound infection treated with antibiotics, 2 patients developed adhesive capsulitis, one patient had not achieved bony union prior to hook plate removal at 16 months, however did achieve union 2 months post plate removal, two patients required revision plating. All patients achieved bony union eventually with good alignment and no displacement of the acromioclavicular joint seen on the most recent post operative radiographs. Post plate removal Oxford Shoulder Scores indicated good shoulder function with a mean score of 41.5 (maximum score possible 48 and the range of scores for our cohort was 30–47).

Our data would support the use of hook plates in the treatment of lateral clavicular fractures. All patients achieved union eventually with good alignment and this was reflected in the good functional outcome scores. This study is limited in its small cohort and short-term follow up. More research is required to examine the long term consequences of hook plate surgery in a larger patient population.