INTRODUCTION: CTS is the most common nerve entrapment syndrome. Repeated flexion and extension activities of the wrist coupled with certain finger flexion causes oedema and compression of the median nerve within the carpal tunnel of the wrist. Several treatment options, both conservative and surgical are available to relieve the pressure on the median nerve. Although studies support the efficacy of splinting for CTS the length of splinting, type of splints, day or night use and the effects on other variables are still less agreed. MATERIALS AND METHODS: A
Prospective
The use of spinal anesthesia with adjuvant intra-thecal opioids has been commonly used in total knee arthroplasty without documented clinical benefit. It has been associated with a potential increase in side effects, including nausea, vomiting, pruritus, urinary retention and oxygen usage. This double-blinded RCT investigated whether the addition of epimorph to spinal anesthesia in patients undergoing total knee arthroplasty resulted in superior pain control and decreased narcotic consumption without also causing an increase in postoperative complication rates. We performed a prospective double-blind trial in patients undergoing primary total knee arthroplasty (TKA). Patients were randomised to receive either spinal anesthesia alone or spinal anesthesia with epimorph (150 ug). All patients received infiltration of a local anesthetic cocktail intraoperatively. Both the study patients and staff measuring outcomes were blinded to the experimental treatment received during data collection. Postoperatively, visual analogue scale (VAS) for pain was recorded at 6, 12, 18, 24, 36 and 48hrs and a final value at 1 week. Narcotic use, Foley insertion, oxygen requirements, nausea, vomiting and pruritus were recorded during the course of hospitalisation. Forty-one patients were randomised into each of the spinal with epimorph and spinal alone treatment arms. The groups showed no significant differences in BMI, age, and gender distribution. In the first 12 hours postoperatively there was no difference in VAS for pain between the two groups, however there were significantly lower pain scores in the spinal alone patients at 18 hours (p=0.002), 24 hours (p=0.04) and 48 hours (p = 0.03) compared to the spinal with epimorph group. Narcotic usage was greater in the spinal group during the first 6 hours postoperatively, but beyond this time point narcotic usage was similar between the two groups. Additionally, there was a statistically significant increase in rate of complications with spinal epimorph including nausea (p=0.037) and pruritus (p=0.024). The incidence of urinary retention was greater in the spinal epimorph group, however this did not reach statistical significance. This study demonstrates no clinical benefit with the addition of intra-thecal opioids to spinal anesthetic in primary TKA. In addition to a failing to reduce VAS pain scores and overall narcotic consumption, increased complication rates were seen. For these reasons, this study does not support the use of epimorph in addition to spinal anesthesia for pain control in TKA.
We performed two independent, randomised, controlled trials in order to assess the potential benefits of immediate weight-bearing mobilisation after rupture of the tendo Achillis. The first trial, on operatively-treated patients showed an improved functional outcome for patients mobilised fully weight-bearing after surgical repair. Two cases of re-rupture in the treatment group suggested that careful patient selection is required as patients need to follow a structured rehabilitation regimen. The second trial, on conservatively-treated patients, provided no evidence of a functional benefit from immediate weight-bearing mobilisation. However, the practical advantages of immediate weight-bearing did not predispose the patients to a higher complication rate. In particular, there was no evidence of tendon lengthening or a higher re-rupture rate. We would advocate immediate weight-bearing mobilisation for the rehabilitation of all patients with rupture of the tendo Achillis.
To assess the accuracy of posterior and anterolateral methods of injection into the subacromial space (SAS) of the shoulder. Ethical approval was obtained and 50 patients (23 women and 27 men) with mean age of 64.5 years (42-87 years) and clinical diagnosis of subacromial impingement were recruited. Patients with old or recent shoulder fracture, bleeding disorders, and allergy to iodine were excluded. All injections were given by the consultant or an experienced registrar after obtaining informed consent. Patients were randomised into posterior and anterolateral groups and the method of injection was revealed by opening sealed envelopes just before the injection. A combination of 3mls 0.5% bupivacaine and 2mls of radiographic dye (Niopam) was injected in the subacromial space (SAS) using either anterolateral (n-22) and posterior approaches (28). AP and lateral radiographs of shoulder were taken after injection and were reported by a Consultant Radiologist blinded to the method of injection. Visual analogue scale (VAS) and Constant-Murley shoulder score was used to assess pain and function respectively. Both scores were determined before and 30 minutes after the injection.Aims
Patients and methods
Knee flexion is often decreased in severe arthritis causing pain, and functional limitations in lifestyles and occupations. Newer knee replacement designs offer the possibility of greater knee motion. The objective of our study was to compare the clinical outcomes, in particular the range of motion, in patients treated with a total knee arthroplasty using either a standard posterior stabilized knee prosthesis or a high flexion posterior stabilized knee prosthesis, with regard to return to function within 1 year of surgery. This was a prospective randomized single blinded study. Forty patients were randomly assigned to receive either a standard fixed bearing posterior stabilized or a modified high flexion fixed bearing posterior stabilized Smith &
Nephew Genesis II total knee joint replacement. Clinical outcomes were determined from data collected on all patients who were evaluated pre-operatively, at twelve weeks post-operatively, and at one year post-operatively. Data collected included SF-12, WOMAC, and Oxford knee scores, and knee range of motion measurements. 37 of 40 patients enrolled completed the study. 22 patients were randomized to receive a standard posterior stabilized fixed bearing Genesis II knee replacement and 22 were randomized to receive a Hi-Flex posterior stabilized fixed bearing knee replacement. ROM, quality of life, and clinical scores at 12 months will be presented.
This multi-centre single-blind randomised control trial compared outcomes in patients with acute displaced mid-shaft clavicle fractures treated either by primary open reduction and plate fixation (ORPF), or non-operative treatment (NT). Two-hundred patients were randomised to receive either ORPF or NT. Functional assessment was conducted up to one-year using DASH, SF-12 and Constant scores (CS). Union was evaluated using radiographs and CT. Rate of non-union was significantly reduced after ORPF (1 following ORPF, 16 following NT, odds ratio=0.07, 95% CI=0.01–0.50, p=0.0006). 7 patients had delayed-union after NT. Group allocation to ORPF was independently predictive of development of non-union. DASH and CS were significantly better in the ORPF group 3-months post-surgery, but not at one-year (mean DASH = 6.2 after NT versus 3.7 after ORPF, p=0.09; mean CS = 86.1 after NT versus 90.7 after ORPF, p=0.05). Group allocation was not predictive of one-year outcome. Non-union was the only factor independently predictive of one-year functional outcome. There were no significant differences in time off work or subjective scores. Five patients underwent revision for complications after ORPF. 10 patients underwent metalwork removal. Treatment cost was significantly greater after ORPF (p=0.001). ORPF reduces rate of non-union compared with NT and is associated with better early functional outcomes. Improved outcomes are not sustained at one-year. Differences in functional outcome appear to be mediated by prevention of non-union from ORPF. ORPF is more expensive and associated with implant-related complications not seen with NT. Our results do not support routine primary ORPF for displaced mid-shaft clavicle fractures.
A recent multicentre randomized control trial (RCT) failed to demonstrate superior quality of life at one year following open reduction and internal fixation (ORIF) compared to nonoperative treatment for unstable isolated fibular fractures. We sought to determine the cost-effectiveness of ORIF compared to non-operative management of unstable fibular fractures. A decision tree was used to model the results of a multicentre trial comparing ORIF versus nonoperative treatment for isolated fibular fractures. A single payer, governmental perspective was used for the analysis. Utilities (a measure of preference for a health state) were obtained from the subjects Short-Form-6D scores and used to calculated Quality Adjusted Life Years (QALYs). Probabilities for each strategy were taken from the one-year trial endpoint. Costs were obtained from the Ontario Case Costing Initiative. Sensitivity analysis was performed for all model variables to determine when ORIF is a cost-effective treatment (incremental cost per QALY gained < $75,000).Purpose
Method
Primary mechanical stability is important with uncemented THR because early migration is reduced, leading to more rapid osseointegration between the implant and bone. Such primary mechanical stability is provided by the design features of the device. The aim of this study was to compare the migration patterns of two uncemented hip stems, the Furlong Active and the Furlong HAC stem; the study was designed as a randomised control trial. The implants were the Furlong HAC, which is an established implant with good long term results, and the Furlong Active, which is a modified version of the Furlong HAC designed to minimise stress concentrations between the implant and bone, and thus to improve fixation. The migration of 43 uncemented femoral components for total hip replacement was measured in a randomised control trial using Roentgen Stereophotogrammetric Analysis (RSA) over two years. Twenty-three Furlong HAC and twenty Furlong Active stems were implanted into 43 patients. RSA examinations were carried out post-operatively, and at six months, 12 months and 24 months post-operatively. The patients stood in-front of a purpose made calibration frame which contained accurately positioned radio-opaque markers. From the obtained images, the 3-D positions of the prosthesis and the host bone were reconstructed. Geometrical algorithms were used to identify the components of the implant. These algorithms allowed the femoral component to be studied without the need to attach markers to the prosthesis. The migration was calculated relative to the femoral coordinate system representing the anterior-posterior (A-P), medial-lateral (M-L) and proximal-distal (P-D) directions respectively. Distal migration was termed subsidence.Introduction
Materials and methods
Quadriceps femoris muscle weakness has long been associated with disuse atrophy in symptomatic knee osteoarthritis but more recently implicated in the aetiology of this condition. The purpose of this study was to assess the benefits of two interventions aimed at increasing quadriceps strength in subjects with moderate to severe knee osteoarthritis. Twenty-eight patients, aged fifty-five to seventy-five, were recruited and randomised to either a six-week home resistance-training exercise program or a six-week neuromuscular electrical stimulation (NMES) program. Eleven patients matched for age, gender and osteoarthritis severity formed a control group, receiving standard care. The resistance-training group performed six exercises three times per week, while the NMES group used the garment stimulator for twenty minutes five times per week Outcome measures included isometric and isokinetic quadriceps strength, functional capacity, quadriceps cross-sectional area, and validated health survey scores. These measures were assessed at baseline, post-intervention and at 6-weeks post-intervention. Both intervention groups showed significant improvements in all functional tests, in the global health survey, and in quadriceps cross-sectional area immediately post-intervention. An increase in isokinetic strength was seen in the exercise group only. With the exception of isokinetic strength, all benefits were maintained six weeks post-intervention. Both a six-week home resistance-training program and a six-week NMES program produce significant improvements in functional performance as well as physical and mental health for patients with moderate to severe knee osteoarthritis. Home-based NMES is an acceptable alternative to physical therapy, and is especially appropriate for patients who have difficulty complying with an exercise program.
Despite evidence of long term survival of cemented femoral stem prostheses, studies have shown concerns in the longevity of the cemented sockets. This has led to a rise in the use of uncemented and hybrid implants (with uncemented cup and cemented stem) without long term studies to determine evidence for their use. We aimed to assess whether there is any difference in clinical outcome between cemented and non-cemented acetabular fixation in elderly patients. Between February 2001 and August 2006 186 patients over 72 years of age were prospectively randomised to receive either a cemented Exeter cup or a HA coated press fit cementless cup. Both groups received a cemented Exeter stem. The patients were assessed pre-operatively and reviewed at 6 weeks, 6 months and yearly in a research clinic, by an independent observer. Outcome measures were the Merle D'Aubigné, Postel, Oxford Hip and Visual analogue pain scores. The implants were also assessed radiographically and all complications were recorded.Introduction
Patients and Methods
Osseous first ray surgery is a common day case procedure. Patients are often given regional blocks. We sought to find if there is a difference between ankle block and metatarsal block in this group of patients. After ethical approval was granted and power analysis performed, 25 patients were recruited into each arm of the study. These patients were having either an osteotomy or arthrodesis. All patients had standardised general anaesthesia and received 20mls of 0.5% chirocaine for the blockade. The cohort having the ankle block had infiltration under ultrasound guidance in the anaesthetic room; and the cohort receiving the metatarsal block had infiltration at the end of the procedure. The timings of both the anaesthesia and the operation were recorded for each patient. Patients scored their pain level at 2, 6 and 24 hours. The amount of post-operative analgesia used in the first 24 hours was also recorded by the research nurse. All patients were discharged home with a standardised prescription of analgesia. Analysis of the pain scores showed that there was no difference between the two blocks at any measured time period. Nor was there a difference in the analgesic requirement in the first 24 hours. There was, however, a difference in the time taken for the whole procedure: with the ankle block taking an average of ten minutes more. We conclude that metatarsal blocks are as effective as ankle blocks in providing pain relief after osseous first ray surgery, and may be a more efficient use of time.
Absorbable cement restrictors have been in use over the last few years. They have been shown to be as effective as the standard non-absorbable cement restrictors in achieving cement pressurisation and stopping distal cement migration in in vitro studies. The aim of this study is to compare in vivo, the effectiveness of absorbable with non-absorbable cement restrictors. One hundred and thirty-six consecutive patients who had total hip replacement performed using charnley cemented femoral prosthesis were selected and randomly divided in to two groups pre operatively. One group received Hardinge TM non-absorbable cement restrictor and the second group received Biostop TM absorbable cement restrictor. Type of the prosthesis, the surgical approach, the time from start of mixing of the cement to insertion of the cement (measure of viscosity of the cement), the cementing technique and the distance at which the cement restrictor was inserted were noted intraoperatively, the canal diameter was measured from the preoperative AP radiograph of the hip. The distance at which the cement restrictor was inserted was measured on the AP radiograph of the hip taken twenty-four hours postoperatively. All the above factors were statistically assessed as to their effect in the distal migration on cement restrictor using multiple regression analysis. There was no statistical difference between the two types of cement restrictors (P= 0.44). Surgeon, Surgical approach, femoral canal diameter P>
0.2 cementing technique P>
0.1 and Cement viscosity P= 0.082 had no effect on the degree of distal migration of the cement. In conclusion Biostop TM absorbable cement restrictor is as effective as Hardinge TM non-absorbable cement restrictor. We could not show any relationship between femoral canal diameter cementing technique and cement viscosity and distal cement migration which leads us to conclude that in the presence of adequate cement restriction these factors have little effect in distal migration of cement mantle.
The available treatments for NSLBP (Non-Specific Low Back Pain) provide, typically, small to moderate average benefits to patients. The aim of this pilot cluster RCT was to test the hypothesis that the use of a patient decision aid together with an informed shared decision making consultation would produce better outcomes in satisfaction with treatment at four month follow-up. We developed a DSP (Decision Support Package). We randomised the physiotherapists and trained those in the intervention arm in informed shared decision making and communication. Participants were recruited from a local physiotherapy department and those allocated to an appointment with an intervention therapist were sent a copy of the DSP in the post. Participants then attended their appointment as usual.Background
Methods
The incidence of DVT and need for thrombo-prophylaxis following isolated distal lower extremity fractures is unknown. The purpose of this study was to determine whether or not thrombo-prophylaxis with low molecular weight heparin was needed in this trauma population. A Multicentered Prospective Randomised Double Blind Placebo Controlled Trial was designed to define the incidence of DVT and need for thrombo-prophylaxis in this population. A sample size of two hundred and ninety-nine patients ensured a one tailed type one error of alpha = 0.05 and power of 80% as confirmed from previous studies. Males and female patients between the ages of eighteen and seventy-five years with isolated distal lower extremity fractures (excluding the foot) were eligible. All patients had surgery within forty-eight hours after injury. Patients excluded from the trial were polytrauma patients, those medically unfit for the operating room, patients with foot fractures, those receiving anticoagulation, inability to provide consent, platelets 200 umol /L. Randomization was carried out via computer generation to receive either placebo or Fragmin for fourteen days. At fourteen days, all patients underwent bilateral venograms interpreted by three independent radiologists. Equivocal venograms were interpreted by consensus. Routine follow-up was carried out for all patients at two, six, eight and twelve weeks. A total of two hundred and ninety-nine patients were enrolled in the study. One hundred thirty-six patients in the Fragmin group and one hundred and twentyfive in the placebo group completed the intervention. There were one hundred and twenty-five males and one hundred and thirty-six females in total. There was no statistically significant difference in DVT incidence between those patients treated with Fragmin or Placebo (p = 0.41). Gender, medical issues, pre-operative level of activity and body mass index had no effect on the incidence of DVT. The incidence of DVT in fragmin treated and placebo treated patients is 8.1% and 11.2%, respectively (p = 0.41). This study suggests that DVT thrombo-prophylaxis is not indicated in this patient population. To our knowledge, this is the first Randomised Controlled Trial utilizing venograms (gold standard) for DVT identification.
Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. The purpose of this multicentre randomized double-blind controlled study was to compare the functional outcomes and healing rates of double-row suture techniques with single row repair. Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a double row (DR) or single row (SR) repair. The primary objective was to compare the WORC score at 24 months. Secondary objectives included anatomical outcomes by MRI or ultrasound, the Constant, and ASES scores. A sample size calculation determined that 84 patients provided 80% power with a 50% effect size to detect a statistical difference between groups.Purpose
Method
We conducted a multicentre two arm double blind randomised controlled trial to assess efficacy of pulsed ultrasound for accelerating the rate of bone healing. Sixty-two skeletally mature adults undergoing limb lengthening, of between 2.5cm to 10cm by distraction osteogenesis, at the proximal tibia using an Ilizarov frame were randomised to either an active or a placebo (control) ultrasound device. Primary outcome measure was time ready for removal of frame after adjusting for distraction length (days/cm) for both intension to treat (ITT) and per protocol (PP) patients. The time at which the frame was removed was determined by the maturation of the regenerate bone. Secondary outcomes were return to weight bearing and covariates affecting time to frame removal. The baseline characteristics of the two groups were well balanced, and 90% of patients were managed and followed up as PP. There was no difference in the time to frame removal between the two groups for the ITT (5.0days/cm, p=0.23) or the PP (10.1days/cm, p=0.054). There was no difference in return to weight bearing between the two groups, after adjusting for distraction length, for the ITT or PP patients (p>0.5). Smoking was the only covariate identified to increase the frame removal time (hazard ratio 0.46, 95% confidence interval 0.22 to 0.96; p=0.04). This trial demonstrated no difference in bone healing between those who underwent pulsed ultrasound and those who did not. Smoking was observed to have a significant inhibitory effect on bone healing.
To assess efficacy of pulsed ultrasound for accelerating regenerate consolidation. A multicentre two arm patient and assessor double blind RCTObjective:
Design:
This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration. Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term.
ECSWT has been on the medical horizon for last 30 years mainly in urology for urolithiasis and has found a parallel use in orthopaedics for various chronic soft tissue conditions like Tendoachilles tendinoses and plantar fasciitis etc. ECSWT acts a piezoelectric device releasing acoustic energy and causing micro-trauma activating cytokine mediated response stimulating local angiogenesis and tissue repair. 56 patients were recruited for the trial after ethics approval was achieved. The diagnosis was confirmed with ultrasound scan and measuring the width of the swelling and the local hypervascularity. The cohort of the patients was randomised in groups for physiotherapy [n=23] and shockwave therapy [n= 23]. The patient groups with shockwave therapy received a 3-week treatment with typical 2000 impulses per session once a week and physiotherapy group was subjected to eccentric loading exercises. Patients were assessed at 12 week with AOFAS, VISA-A scores and repeat ultrasound scan. The average age of the average age was 51 years [36- 73 years] Mean duration of symptoms prior to treatment was 25 months (range 6-60 months). AOFAS scores increased in both groups: from 64□86 in the ECSWT group and 72□79 in the physiotherapy group. VISA-A scores also increased in both groups from 39□73 in the ECSWT group and from 36□56 in the physiotherapy group. Scores were significantly higher in the ECWST group post treatment. The ultrasound scan findings suggested the tendon girth receding from 10.9 mm□9.9 mm in physiotherapy group while 9.8 mm□8.7 mm in the ECSWT group with hypervascularity decreasing from marked to mild in both groups. Statistical significance was established using SPSS 16 p < 0.001in post treatment group.Methodology
Results
We previously compared component alignment in total knee replacement using a computer-navigated technique with a conventional jig based method. Improved alignment was seen in the computer-navigated group (Beaver et al. JBJS 2004 (86B); 3: 372–7.). We also reported two-year results showing no difference in clinical outcome between the two groups (Beaver et al. JBJS 2007 (89B); 4: 477–80). We now report our five-year functional results comparing navigated and conventional total knee replacement. To our knowlege this represents the first Level 1 study comparing function in navigated and conventional total knee replacement at five years. An original cohort of 71 patients undergoing Duracon (Stryker Orthopaedics, St. Leonards, Australia) total knee replacement without patellar resurfacing were prospectively randomised to undergo operation using computer navigation (Stryker Image Free Computer Navigation System (version 1.0; Stryker Orthopaedics))(n=35) or a jig-based method (n=36). The two groups were matched for age, gender, height, weight, BMI, ASA grade and pre-operative deformity. All operations were performed by a single surgeon. All patients underwent review in our Joint Replacement Assessment Clinic at 3, 6 and 12 months and at 2 and 5 years. Reviews were undertaken by senior physiotherapist blinded to participant status using validated outcome scoring tools (Knee Society Score, WOMAC Score and Short Form SF-36 Score). All patients underwent CT scanning of the implanted prosthesis as per Perth CT Knee Protocol to assess component alignment. After 5 years 24 patients in the navigated group and 22 patients in the conventional group were available for review. At 5 years no statistically significant difference was seen in any of the aforementioned outcome scores when comparing navigated and conventional groups. No statistically significant difference was seen between 2- and 5-year results for either group. Due to the relatively low numbers in each group these data were compared with retrospective cohorts of navigated (n=100) and conventional (n=70) Duracon total knee replacements performed outwith this study over the same 5-year period. WITHIN the retrospective cohorts no statistically significant differences were found when comparing any of the aforementioned outcome scores. In addition, when comparing parallel scores between prospective and retrospective groups again no statistically significant differences were identified. At 5-years post-operatively the functional outcome between computer navigated and conventional total knee replacement appears to be no different despite the better alignment achieved using navigation.
Due to the relatively low numbers in each group these data were compared with retrospective cohorts of navigated (n=100) and conventional (n=70) Duracon total knee replacements performed outwith this study over the same 5-year period. WITHIN the retrospective cohorts no statistically significant differences were found when comparing any of the aforementioned outcome scores. In addition, when comparing parallel scores between prospective and retrospective groups again no statistically significant differences were identified.
Both groups had statistically improved post-operative hip scores, however, at the 1 year follow-up the MIS group were significantly better in terms of WOMAC, Harris Hip, Merle d’Aubigne and SF-12 scores when compared with a standard posterior approach.
This study was performed to investigate the efficacy of steroid and local anaesthesia (LA) in reducing post-operative pain in lumbar discectomy. The study was ethically approved. Patients undergoing primary single level lumbar discectomy were randomised by a closed envelope system into 4 groups, which were (Group 1) 10mg of adcortyl in 1ml and 1ml of 0.5% marcaine, (Group 2) 10mg of adcortyl and 1ml of normal saline, (Group 3) 1ml of 0.5% marcaine and 1ml of normal saline and (Group 4) 2mls of normal saline as control. Combinations of the above were applied topically over the nerve root prior to closure. Pre-operative, day 1 and eight weeks post-operative pain scores were recorded. 24 hours post-operative opiate analgesia requirements and duration of inpatient stay were recorded. Data were analysed using student t-test for statistical significance.Introduction
Materials and methods
Controversy exists whether to treat unstable pertrochanteric hip fractures with either intra-medullary or extra-medullary devices. A prospective randomised control trial was performed to compare the outcome of unstable pertrochanteric hip fractures stabilised with either a sliding hip screw or long Gamma Nail. The hypothesis was that there is no difference in outcome between the two modes of treatment. Over a four year period, 210 patients presenting with an unstable pertrochanteric hip fracture (AO/OTA 31 A2) were recruited into the study. Eligible patients were randomised on admission to either long Gamma Nail or sliding hip screw. Follow-up was arranged for three, six, and twelve months. Primary outcome measures were implant failure or ‘cut-out’. Secondary measures included mortality, length of hospital stay, transfusion rate, change in mobility and residence, and EuroQol outcome score. Five patients required revision surgery for implant cut-out (2.5%), of which three were long Gamma Nails and two were sliding hip screws (no significant difference). There were no incidences of implant failure or deep infection. Tip apex distance was found to correlate with implant cut-out. There was no statistically significant difference in either the EuroQol outcome scores or mortality rates between the two groups when corrected for mini mental score. There was no difference in transfusion rates, length of hospital stay, and change in mobility or residence. There was a clear cost difference between the implants. The sliding hip screw remains the gold standard in the treatment of unstable pertrochanteric fractures of the proximal femur.
The aim of this study was to compare long term outcomes of usual surgical advice, involving no formal post-surgical rehabilitation, with a non-aggravating six month gym rehabilitation programme post lumbar discectomy. This study is a prospective randomized controlled trial using a cohort followed for three years.
Scoliosis is a lateral curvature of the spine with associated rotation, often causing distress due to appearance. For some curves, there is good evidence to support the use of a spinal brace, worn for 20 to 24 hours a day to minimize the curve, making it as straight as possible during growth, preventing progression. Compliance can be poor due to appearance and comfort. A night-time brace, worn for eight to 12 hours, can achieve higher levels of curve correction while patients are supine, and could be preferable for patients, but evidence of efficacy is limited. This is the protocol for a randomized controlled trial of ‘full-time bracing’ versus ‘night-time bracing’ in adolescent idiopathic scoliosis (AIS). UK paediatric spine clinics will recruit 780 participants aged ten to 15 years-old with AIS, Risser stage 0, 1, or 2, and curve size (Cobb angle) 20° to 40° with apex at or below T7. Patients are randomly allocated 1:1, to either full-time or night-time bracing. A qualitative sub-study will explore communication and experiences of families in terms of bracing and research. Patient and Public Involvement & Engagement informed study design and will assist with aspects of trial delivery and dissemination.Aims
Methods
Torus fractures of the distal radius are the most common fractures in children. The NICE non-complex fracture guidelines recently concluded that bandaging was probably the optimal treatment for these injuries. However, across the UK current treatment varies widely due to a lack of evidence underpinning the guidelines. The Forearm Fracture Recovery in Children Evaluation (FORCE) trial evaluates the effect of a soft bandage and immediate discharge compared with rigid immobilization. FORCE is a multicentre, parallel group randomized controlled equivalence trial. The primary outcome is the Wong-Baker FACES pain score at three days after randomization and the primary analysis of this outcome will use a multivariate linear regression model to compare the two groups. Secondary outcomes are measured at one and seven days, and three and six-weeks post-randomization and include the Patient Reported Outcome Measurement Information System (PROMIS) upper extremity limb score, EuroQoL EQ-5D-Y, analgesia use, school absence, complications, and healthcare resource use. The planned statistical and health economic analyses for this trial are described here. The FORCE trial protocol has been published separately.Aims
Methods
Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less systemic adverse effects, and promising results have been reported in systematic reviews of its use in spine surgery. This study aims to analyse the efficacy and adverse effect profile of intra-wound antibiotics in reducing surgical site infections in orthopaedic surgery for traumatic pelvic and lower limb fractures. A systematic review was conducted for studies reporting on the incidence of surgical site infections following administration of intra-wound antibiotic powder in pelvic and lower limb trauma surgery.
This systematic review and meta-analysis aimed to compare the outcome of operative and non-operative management in adults with distal radius fractures, with an additional elderly subgroup analysis. The main outcome was 12-month PRWE score. Secondary outcomes included DASH score, grip strength, complications and radiographic parameters.
The number of surgical procedures performed each year to treat
femoroacetabular impingement (FAI) continues to rise. Although there
is evidence that surgery can improve symptoms in the short-term,
there is no evidence that it slows the development of osteoarthritis
(OA). We performed a feasibility study to determine whether patient
and surgeon opinion was permissive for a Randomised Controlled Trial
(RCT) comparing operative with non-operative treatment for FAI. Surgeon opinion was obtained using validated questionnaires at
a Specialist Hip Meeting (n = 61, 30 of whom stated that they routinely
performed FAI surgery) and patient opinion was obtained from clinical
patients with a new diagnosis of FAI (n = 31).Objectives
Methods
We present the ten-year data of a cohort of patients, aged between
18 and 65 years (mean age 52.7 years; 19 to 64), who underwent total
hip arthroplasty. Patients were randomised to be treated with a
cobalt-chrome (CoCr) femoral head with an ultra-high molecular weight
polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE) or
ceramic-on-ceramic (CoC) bearing surface. A total of 102 hips (91 patients) were randomised into the three
groups. At ten years, 97 hips were available for radiological and
functional follow-up. Two hips (two patients) had been revised (one
with deep infection and one for periprosthetic fracture) and three
were lost to follow-up. Radiological analysis was performed using
a validated digital assessment programme to give linear, directional
and volumetric wear of the two polyethylene groups.Aims
Patients and Methods
This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group. A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.Objectives
Methods
The aim of this study was to determine whether the sequential
application of povidone iodine-alcohol (PVI) followed by chlorhexidine
gluconate-alcohol (CHG) would reduce surgical wound contamination
to a greater extent than PVI applied twice in patients undergoing
spinal surgery. A single-centre, interventional, two arm, parallel group randomised
controlled trial was undertaken, involving 407 patients who underwent
elective spinal surgery. For 203 patients, the skin was disinfected before surgery using
PVI (10% [w/w (1% w/w available iodine)] in 95% industrial denatured
alcohol, povidone iodine; Videne Alcoholic Tincture) twice, and
for 204 patients using PVI once followed by CHG (2% [w/v] chlorhexidine
gluconate in 70% [v/v] isopropyl alcohol; Chloraprep with tint).
The primary outcome measure was contamination of the wound determined
by aerobic and anaerobic bacterial growth from samples taken after
disinfection.Aims
Patients and Methods
The aim of this study was to compare the effectiveness of a femoral
nerve block and a periarticular infiltration in the management of
early post-operative pain after total knee arthroplasty (TKA). A pragmatic, single centre, two arm parallel group, patient blinded,
randomised controlled trial was undertaken. All patients due for
TKA were eligible. Exclusion criteria included contraindications
to the medications involved in the study and patients with a neurological
abnormality of the lower limb. Patients received either a femoral
nerve block with 75 mg of 0.25% levobupivacaine hydrochloride around
the nerve, or periarticular infiltration with 150 mg of 0.25% levobupivacaine
hydrochloride, 10 mg morphine sulphate, 30 mg ketorolac trometamol
and 0.25 mg of adrenaline all diluted with 0.9% saline to make a
volume of 150 ml.Aims
Patients and Methods
The objective of this five-year prospective, blinded, randomised
controlled trial (RCT) was to compare femoral head penetration into
a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner
with penetration into a medium cross-linked polyethylene control
liner using radiostereometric analysis. Patients scheduled for total hip arthroplasty (THA) were randomised
to receive either the study E1 (32 patients) or the control ArComXL
polyethylene (35 patients). The median age (range) of the overall
cohort was 66 years (40 to 76).Aims
Patients and Methods
The PROximal Fracture of the Humerus Evaluation by Randomisation
(PROFHER) randomised clinical trial compared the operative and non-operative
treatment of adults with a displaced fracture of the proximal humerus
involving the surgical neck. The aim of this study was to determine
the long-term treatment effects beyond the two-year follow-up. Of the original 250 trial participants, 176 consented to extended
follow-up and were sent postal questionnaires at three, four and
five years after recruitment to the trial. The Oxford Shoulder Score
(OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent
shoulder operations and fracture data were collected. Statistical
and economic analyses, consistent with those of the main trial were
applied.Aims
Patients and Methods
The appropriate management for patients with a degenerative tear
of the rotator cuff remains controversial, but operative treatment,
particularly arthroscopic surgery, is increasingly being used. Our
aim in this paper was to compare the effectiveness of arthroscopic
with open repair of the rotator cuff. A total of 273 patients were recruited to a randomised comparison
trial (136 to arthroscopic surgery and 137 to open surgery) from
19 teaching and general hospitals in the United Kingdom. The surgeons
used their usual preferred method of repair. The Oxford Shoulder
Score (OSS), two years post-operatively, was the primary outcome
measure. Imaging of the shoulder was performed at one year after
surgery. The trial is registered with Current Controlled Trials,
ISRCTN97804283.Aims
Patients and Methods
Knee joint distraction (KJD) is a relatively new, knee-joint
preserving procedure with the goal of delaying total knee arthroplasty
(TKA) in young and middle-aged patients. We present a randomised
controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis
were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes
were assessed at baseline, three, six, nine, and 12 months. In the
KJD group, the joint space width (JSW) was radiologically assessed,
representing a surrogate marker of cartilage thickness.Aims
Patients and Methods
The optimal treatment for independent patients with a displaced
intracapsular fracture of the hip remains controversial. The recognised
alternatives are hemiarthroplasty and total hip arthroplasty. At
present there is no established standard of care, with both types
of arthroplasty being used in many centres. We conducted a feasibility study comparing the clinical effectiveness
of a dual mobility acetabular component compared with standard polyethylene
component in total hip arthroplasty for independent patients with
a displaced intracapsular fracture of the hip, for a 12-month period
beginning in June 2013. The primary outcome was the risk of dislocation
one year post-operatively. Secondary outcome measures were EuroQol
5 Dimensions, ICEpop CAPability measure for Older people, Oxford
hip score, mortality and re-operation.Aims
Patients and Methods
The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos
R) bone cement is no longer commercially available and was superseded
by Refobacin bone cement R and Palacos R + G in 2005. However, the
performance of these newly introduced bone cements have not been
tested in a phased evidence-based manner, including roentgen stereophotogrammetric
analysis (RSA). In this blinded, randomised, clinical RSA study, the migration
of the Stanmore femoral component was compared between Refobacin
bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties.
The primary outcome measure was femoral component migration measured
using RSA and secondary outcomes were Harris hip score (HHS), Hip
disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D)
and Short Form 36 (SF-36).Aims
Patients and Methods
We wished to compare the clinical outcome, as assessed by questionnaires
and the rate of complications, in total knee arthroplasty (TKA)
undertaken with patient-matched positioning guides (PMPGs) or conventional
instruments. A total of 180 patients (74 men, 106 women; mean age 67 years)
were included in a multicentre, adequately powered, double-blind,
randomised controlled trial. The mean follow-up was 44 months (24
to 57).Aims
Patients and Methods
Abstract. Background. Recruitment of patients to participate in
Subtotal or total meniscectomy in the medial or lateral compartment
of the knee results in a high risk of future osteoarthritis. Meniscal
allograft transplantation has been performed for over thirty years
with the scientifically plausible hypothesis that it functions in
a similar way to a native meniscus. It is thought that a meniscal
allograft transplant has a chondroprotective effect, reducing symptoms
and the long-term risk of osteoarthritis. However, this hypothesis has
never been tested in a high-quality study on human participants.
This study aims to address this shortfall by performing a pilot
randomised controlled trial within the context of a comprehensive
cohort study design. Patients will be randomised to receive either meniscal transplant
or a non-operative, personalised knee therapy program. MRIs will
be performed every four months for one year. The primary endpoint
is the mean change in cartilage volume in the weight-bearing area
of the knee at one year post intervention. Secondary outcome measures
include the mean change in cartilage thickness, T2 maps, patient-reported
outcome measures, health economics assessment and complications.Objectives
Methods
We performed a randomised controlled trial comparing
computer-assisted surgery (CAS) with conventional surgery (CONV)
in total knee replacement (TKR). Between 2009 and 2011 a total of
192 patients with a mean age of 68 years (55 to 85) with osteoarthritis
or arthritic disease of the knee were recruited from four Norwegian
hospitals. At three months follow-up, functional results were marginally
better for the CAS group. Mean differences (MD) in favour of CAS
were found for the Knee Society function score (MD: 5.9, 95% confidence
interval (CI) 0.3 to 11.4, p = 0.039), the Knee Injury and Osteoarthritis
Outcome Score (KOOS) subscales for ‘pain’ (MD: 7.7, 95% CI 1.7 to
13.6, p = 0.012), ‘sports’ (MD: 13.5, 95% CI 5.6 to 21.4, p = 0.001)
and ‘quality of life’ (MD: 7.2, 95% CI 0.1 to 14.3, p = 0.046).
At one-year follow-up, differences favouring CAS were found for
KOOS ‘sports’ (MD: 11.0, 95% CI 3.0 to 19.0, p = 0.007) and KOOS
‘symptoms’ (MD: 6.7, 95% CI 0.5 to 13.0, p = 0.035). The use of
CAS resulted in fewer outliers in frontal alignment (>
3° malalignment),
both for the entire TKR (37.9% Cite this article:
In the absence of patellar resurfacing, we have
previously shown that the use of electrocautery around the margin of
the patella improved the one-year clinical outcome of total knee
replacement (TKR). In this prospective randomised study we compared
the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed
with and without electrocautery of the patellar rim: this is an
update of a previous report. The overall prevalence of anterior knee
pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95%
CI 18 to 35) in the intervention group compared with 38% (95% CI
29 to 48) in the control group (chi-squared test; p = 0.06). The
overall prevalence of anterior knee pain remained unchanged between
the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The
mean total Western Ontario McMasters Universities Osteoarthritis
Indices and the American Knee Society knee and function scores at
3.7 years’ follow-up were similar in the intervention and control
groups (repeated measures analysis of variance p = 0.43, p = 0.09
and p = 0.59, respectively). There were no complications. A total
of ten patients (intervention group three, control group seven)
required secondary patellar resurfacing after the first year. Our study suggests that the improved clinical outcome with electrocautery
denervation compared with no electrocautery is not maintained at
a mean of 3.7 years’ follow-up. Cite this article:
We investigated whether, in the management of
stable paediatric fractures of the forearm, flexible casts that
can be removed at home are as clinically effective Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for independent patients with displaced intracapsular fractures
of the proximal femur. The recognised alternatives are hemiarthroplasty
and total hip replacement. At present there is no established standard
of care, with both types of arthroplasty being used in many centres.
The principal advantages of total hip replacement are a functional
benefit over hemiarthroplasty and a reduced risk of revision surgery.
The principal criticism is the increased risk of dislocation. We
believe that an alternative acetabular component may reduce the
risk of dislocation but still provide the functional benefit of
total hip replacement in these patients. We therefore propose to
investigate the dislocation risk of a dual-mobility acetabular component
compared with standard polyethylene component in total hip replacement
for independent patients with displaced intracapsular fractures
of the proximal femur within the framework of the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. Controversy exists regarding
the optimal treatment for patients with unstable trochanteric proximal
femoral fractures. The recognised treatment alternatives are extramedullary
fixation usually with a sliding hip screw and intramedullary fixation
with a cephalomedullary nail. Current evidence suggests that best
results and lowest complication rates occur using a sliding hip screw.
Complications in these difficult fractures are relatively common
regardless of type of treatment. We believe that a novel device,
the X-Bolt dynamic plating system, may offer superior fixation over
a sliding hip screw with lower reoperation risk and better function.
We therefore propose to investigate the clinical effectiveness of
the X-bolt dynamic plating system compared with standard sliding
hip screw fixation within the framework of a the larger WHiTE (Warwick
Hip Trauma Evaluation) Comprehensive Cohort Study. Cite this article:
There is conflicting evidence about the merits
of mobile bearings in total knee replacement, partly because most randomised
controlled trials (RCTs) have not been adequately powered. We report
the results of a multicentre RCT of mobile There was no significant difference between the groups pre-operatively:
mean OKS was 17.18 ( In this appropriately powered RCT, over the first five years
after total knee replacement functional outcomes, re-operation rates
and healthcare costs appear to be the same irrespective of whether
a mobile or fixed bearing is used. Cite this article:
The best treatment for the active and lucid elderly patient with a displaced intracapsular fracture of the femoral neck is still controversial.
Implant choice was changed from cemented Thompson to Exeter Trauma Stem (ETS) for treatment of displaced intra-capsular neck of femur fractures in University Hospital Aintree, Liverpool, United Kingdom (a major trauma center), following the NICE guidelines that advised about the use of a proven femoral stem design rather than Austin Moore or Thompson stems for hemiarthroplasties. The aim of our study was to compare the results of Thompson versus ETS hemiarthroplasty in Aintree. We initially compared 100 Thompson hemiarthroplasties that were performed before the start of ETS use, with 100 ETS hemiarthroplasties. There was no statistically significant difference between the two groups in terms of patients' demographics (age, sex and ASA grade), intra-operative difficulties/complications, post op medical complications, blood transfusion, in-patient stay and dislocations. The operative time was statistically significantly longer in the ETS group (p= .0067). Worryingly, the 30 days mortality in ETS group was more than three times higher in ETS group (5 in Thompson group versus 16 in ETS group. P= .011). To corroborate our above findings we studied 100 more consecutive patients that had ETS hemiarthroplasty. The results of this group showed 30 day mortality of 8 percent. However the operative time was again significantly longer (p= .003) and there was 18 percent conversion to bipolar hemiarthropalsty. Moreover there was statistically significant increased rate of deep infection (7%, p = .03) and blood transfusion (27%, p = .007). This we feel may be due to longer and more surgically demanding operative technique including pressurised cementation in some patients with significant medical comorbidities. Our results raise the question whether ETS hemiarthoplasty implant is a good implant choice for neck of femur fracture patients.
Background. Total hip replacement (THR) and total knee replacement (TKR) are usually effective at relieving pain; however, 7–23% of patients experience chronic post-surgical pain. These trials aimed to investigate the effect of local anaesthetic wound infiltration on pain severity at 12 months after primary THR or TKR for osteoarthritis. Methods. Between November 2009 and February 2012, 322 patients listed for THR and 316 listed for TKR were recruited into a single-centre double-blind randomised controlled trial. Participants were randomly assigned (1:1) to receive local anaesthetic infiltration and standard care or standard care alone. Participants and outcomes assessors were masked to group allocation. The primary outcome was pain severity on the WOMAC Pain scale at 12 months post-surgery. Analyses were conducted using intention-to-treat and per-protocol approaches. Ethics approval was obtained from Southampton and South West Hampshire Research Ethics Committee. Results. In the hip trial, patients in the intervention group had significantly less pain at 12 months post-operative than patients in the standard care group (differences in means 4.74; 95% CI 0.95, 8.54; p=0.015), although the difference was not clinically significant. Post-hoc analysis found that patients in the intervention group were more likely to have none to moderate pain than severe pain at 12 months than those in the standard care group (odds ratio 10.19; 95% CI 2.10, 49.55; p=0.004). In the knee trial, there was no strong evidence that the intervention influenced pain severity at 12 months post-operative (difference in means 3.83; 95% CI −0.83, 8.49; p=0.107). Conclusions. In conclusion, routine use of infiltration could be beneficial in improving long-term pain relief for some patients after THR. Level of evidence.
Introduction. Wound closure following orthopaedic surgery is an important step requiring careful technique and suitable suture material. The use of subcuticular sutures has been advocated following use in animal models and has also been reported in the literature having been used in specialities such as Orthopaedic Surgery, Plastic Surgery and Obstetrics. Aims. The aim of this study is to assess the use of absorbable subcuticular INSORB® sutures in THR when compared with the standard Autosuture. TM. Signet. TM. metal skin staples. Patient satisfaction with wound appearance was measured at the six week review stage. Wound healing was also noted in the initial stages of recovery and at the six week review stage. Methods. A
Background: Mind body therapies are being used increasingly to manage chronic musculoskeletal pain. We aimed to systematically review studies to explore the effectiveness of these mind-body therapies (MBTs). Method: The following databases were searched MEDLINE, Psychinfo, AMED and CINAHL.
Background: Recurrent peroneal tendon subluxation is uncommon. We report the results of a delayed anatomic repair using suture anchors. Using a case series we tested the null hypothesis that there are no differences between pre- and post-operative status following anatomical repair of the superior peroneal retinaculum. Methods: In the period 1996 to 2001, we operated on 14 patients (all males; average age 25.3 ± 6.3 years, range 18–37) with traumatic recurrent unilateral peroneal tendon subluxation, with a followed up of 38 ± 3 (range 22 to 47) months. Results: No patient experienced a further episode of peroneal tendon subluxation, and all had returned to their normal activities. Maximum calf circumference, functional ability, peak torque, total work and average power of plantar flexion were always lower in the operated leg, but the differences did not reach statistical significance. The AOFAS Ankle-Hindfoot Scale increased significantly from 54.3 ± 11.4 to 94.5 ± 6.4 (p = 0.03), with five patients reporting a fully normal ankle. Conclusion: If an anatomic approach to treating the pathology is utilised, reattachment of the superior retinaculum is a most appropriate technique. It returns patients to a high level of physical activity, and gives high rate of satisfactory results both objectively and subjectively.
Introduction and Aims:
Unicompartmental knee arthroplasty (UKA) has been gaining popularity in recent years due to its perceived benefits over total knee replacements, such as greater bone preservation, reduced operating-room time, better postoperative range of motion and improved gait. However there have been failures associated with UKA caused by misalignment of the implants. To improve the implant alignment a robotic guidance system called the RIO Robotic Arm has been developed by MAKO Surgical Corp (Ft. Lauderdale, FL). This robotic system provides real-time tactile feedback to the surgeon during bone cutting, designed to give improved accuracy compared to traditional UKA using cutting jigs and other manual instrumentation. The University of Strathclyde in association with Glasgow Royal Infirmary has undertaken the first independent
Background: Neck pain is a common problem accounting for up to 22% of the workload of physiotherapists. Many different approaches are used and the evidence for these is unclear. Purpose: To evaluate the effectiveness of a brief physiotherapy intervention (1–3 sessions) for patients with neck pain in the primary care setting, taking preferences into account. Method: A
The aim was to assess whether robotic-assisted total knee arthroplasty (rTKA) had greater knee-specific outcomes, improved fulfilment of expectations, health-related quality of life (HRQoL), and patient satisfaction when compared with manual TKA (mTKA). A randomized controlled trial was undertaken (May 2019 to December 2021), and patients were allocated to either mTKA or rTKA. A total of 100 patients were randomized, 50 to each group, of whom 43 rTKA and 38 mTKA patients were available for review at 12 months following surgery. There were no statistically significant preoperative differences between the groups. The minimal clinically important difference in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score was defined as 7.5 points.Aims
Methods
To synthesise the literature and perform a meta-analysis detailing
the longitudinal recovery in the first two years following a distal
radius fracture (DRF) managed with volar plate fixation. Three databases were searched to identify relevant articles.
Following eligibility screening and quality assessment, data were
extracted and outcomes were assimilated at the post-operative time
points of interest. A state-of-the-art longitudinal mixed-effects
meta-analysis model was employed to analyse the data.Aims
Materials and Methods
Evidence -based medicine (EBM) is designed to inform clinical decision-making within all medical specialties, including orthopaedic surgery. We recently published a pilot survey of the Canadian Orthopaedic Association (COA) membership and demonstrated that the adoption of EBM principles is variable among Canadian orthopaedic surgeons. The objective of this study was to conduct a broader international survey of orthopaedic surgeons to identify characteristics of research studies perceived as being most influential in informing clinical decision-making. A 29-question electronic survey was distributed to the readership of an established orthopaedic journal with international readership. The survey aimed to analyse the influence of both extrinsic (journal quality, investigator profiles, etc.) and intrinsic characteristics (study design, sample size, etc.) of research studies in relation to their influence on practice patterns.Objectives
Materials and Methods
To determine whether the findings from a landmark Canadian trial
assessing the optimal management of acute rupture of the Achilles
tendon influenced the practice patterns of orthopaedic surgeons
in Ontario, Canada. Health administrative databases were used to identify Ontario
residents ≥ 18 years of age with an Achilles tendon rupture from
April 2002 to March 2014. The rate of surgical repair (per 100 cases)
was calculated for each calendar quarter. A time-series analysis
was used to determine whether changes in the rate were chronologically
related to the dissemination of results from a landmark trial published
in February 2009. Non-linear spline regression was then used independently
to identify critical time-points of change in the surgical repair
rate to confirm the findings.Aims
Materials and Methods
Different methods of anterior cruciate ligament (ACL) reconstruction
have been described for skeletally immature patients before closure
of the growth plates. However, the outcome and complications following
this treatment remain unclear. The aim of this systematic review
was to analyse the outcome and complications of different techniques
which may be used for reconstruction of the ACL in these patients. We performed a systematic review of the literature according
to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses
guidelines. This involved a comprehensive search of PubMed, Medline,
CINAHL, Cochrane, Embase and Google Scholar databases using the
following combinations of keywords, “knee”, “anterior cruciate ligament”,
“reconstruction”, “injury”, “children”, “adolescent”, “skeletally
immature”, “open physis” and “surgery”.Aims
Materials and Methods
The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.Objectives
Patients and Methods
As tumours of bone and soft tissue are rare, multicentre prospective collaboration is essential for meaningful research and evidence-based advances in patient care. The aim of this study was to identify barriers and facilitators encountered in large-scale collaborative research by orthopaedic oncological surgeons involved or interested in prospective multicentre collaboration. All surgeons who were involved, or had expressed an interest, in the ongoing Prophylactic Antibiotic Regimens in Tumour Surgery (PARITY) trial were invited to participate in a focus group to discuss their experiences with collaborative research in this area. The discussion was digitally recorded, transcribed and anonymised. The transcript was analysed qualitatively, using an analytic approach which aims to organise the data in the language of the participants with little theoretical interpretation.Objectives
Methods
We performed a systematic review of the current literature regarding
the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. We initially identified 1305 studies, and 406 were found to be
duplicates. After exclusion criteria were applied, seven studies
were included. Outcomes extracted included pre- and post-operative
pain visual analogue scores, range of movement (ROM), strength of
pinch and grip, satisfaction and patient reported outcome measures
(PROMs). Clinical and radiological complications were recorded.
The results are presented in three groups based on the design of
the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA),
pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene
(MoP)).Aims
Materials and Methods
There is uncertainty regarding the optimal means of thromboprophylaxis
following total hip and knee arthroplasty (THA, TKA). This systematic
review presents the evidence for acetylsalicylic acid (aspirin)
as a thromboprophylactic agent in THA and TKA and compares it with
other chemoprophylactic agents. A search of literature published between 2004 and 2014 was performed
in accordance with Preferred Reporting Items for Systematic Reviews
and Meta-Analyses guidelines. A total of 13 studies were eligible
for inclusion.Aims
Materials and Methods
Our aim was to perform a systematic review of the literature
to assess the incidence of post-operative epidural haematomas and
wound infections after one-, or two-level, non-complex, lumbar surgery
for degenerative disease in patients with, or without post-operative
wound drainage. Studies were identified from PubMed and EMBASE, up to and including
27 August 2015, for papers describing one- or two-level lumbar discectomy
and/or laminectomy for degenerative disease in adults which reported
any form of subcutaneous or subfascial drainage.Aims
Patients and Methods
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
We report an audit of 208 patients with a mean age of 39 years (16 to 65) attending the Orthopaedic Assessment Unit at the Wellington Hospital between January 2006 and December 2007 with an injury of the tendo Achillis requiring immobilisation in a cast. Information on assessment of venous thromboembolism (VTE) risk, prophylactic measures and VTE events for all patients was obtained from the medical records. A VTE risk factor was documented in the records of three (1%) patients. One of the 208 patients received aspirin prophylaxis; none received low molecular weight heparin. In all, 13 patients (6.3%, 95% confidence interval 3.4 to 10.5) developed symptomatic VTE during immobilisation in a cast, including six with a distal deep-vein thrombosis (DVT), four with a proximal DVT, and three with a confirmed pulmonary embolus. This incidence of symptomatic VTE is similar to that reported following elective hip replacement. We propose that consideration is given to VTE prophylaxis during prolonged immobilisation of the lower limbs in a cast, to ensure that the same level of protection is provided as for patients undergoing elective hip replacement.
The aim of this study was to review the role
of clinical trial networks in orthopaedic surgery. A total of two
electronic databases (MEDLINE and EMBASE) were searched from inception
to September 2013 with no language restrictions. Articles related
to randomised controlled trials (RCTs), research networks and orthopaedic
research, were identified and reviewed. The usefulness of trainee-led
research collaborations is reported and our knowledge of current
clinical trial infrastructure further supplements the review. Searching
yielded 818 titles and abstracts, of which 12 were suitable for
this review. Results are summarised and presented narratively under
the following headings: 1) identifying clinically relevant research
questions; 2) education and training; 3) conduct of multicentre
RCTs and 4) dissemination and adoption of trial results. This review
confirms growing international awareness of the important role research
networks play in supporting trials in orthopaedic surgery. Multidisciplinary
collaboration and adequate investment in trial infrastructure are crucial
for successful delivery of RCTs. Cite this article:
The optimum cementing technique for the tibial
component in cemented primary total knee replacement (TKR) remains
controversial. The technique of cementing, the volume of cement
and the penetration are largely dependent on the operator, and hence
large variations can occur. Clinical, experimental and computational
studies have been performed, with conflicting results. Early implant
migration is an indication of loosening. Aseptic loosening is the
most common cause of failure in primary TKR and is the product of
several factors. Sufficient penetration of cement has been shown
to increase implant stability. This review discusses the relevant literature regarding all aspects
of the cementing of the tibial component at primary TKR. Cite this article:
Adolescent idiopathic scoliosis affects about
3% of children. Non-operative measures are aimed at altering the natural
history to maintain the size of the curve below 40° at skeletal
maturity. The application of braces to treat spinal deformity pre-dates
the era of evidence-based medicine, and there is a paucity of irrefutable
prospective evidence in the literature to support their use and
their effectiveness has been questioned. This review considers this evidence. The weight of the evidence
is in favour of bracing over observation. The most recent literature
has moved away from addressing this question, and instead focuses
on developments in the design of braces and ways to improve compliance. Cite this article:
Multicentre clinical trials in trauma care are gaining prominence as a means of generating good-quality evidence to inform and influence clinical practice. We believe multicentre trials have an important role to play in supporting evidence-based practice, and further investment in such trials is justified.
To review the current best surgical practice and detail a multi-disciplinary
approach that could further reduce joint replacement infection. Review of relevant literature indexed in PubMed.Objectives
Methods
We performed a systematic review of the literature to determine
whether earlier surgical repair of acute rotator cuff tear (ARCT)
leads to superior post-operative clinical outcomes. The MEDLINE, Embase, CINAHL, Web of Science, Cochrane Libraries,
controlled-trials.com and clinicaltrials.gov databases were searched
using the terms: ‘rotator cuff’, or ‘supraspinatus’, or ‘infraspinatus’,
or ‘teres minor’, or ‘subscapularis’ AND ‘surgery’ or ‘repair’.
This gave a total of 15 833 articles. After deletion of duplicates
and the review of abstracts and full texts by two independent assessors,
15 studies reporting time to surgery for ARCT repair were included.
Studies were grouped based on time to surgery <
3 months (group
A, seven studies), or >
3 months (group B, eight studies). Weighted
means were calculated and compared using Student’s Aims
Methods
We performed a systematic review and meta-analysis
to compare the efficacy of intermittent mechanical compression combined
with pharmacological thromboprophylaxis, against either mechanical
compression or pharmacological prophylaxis in preventing deep-vein
thrombosis (DVT) and pulmonary embolism in patients undergoing hip
or knee replacement. A total of six randomised controlled trials,
evaluating a total of 1399 patients, were identified. In knee arthroplasty,
the rate of DVT was reduced from 18.7% with anticoagulation alone
to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03;
number needed to treat: seven). There was moderate, albeit non-significant,
heterogeneity (I2 = 42%). In hip replacement, there was
a non-significant reduction in DVT from 8.7% with mechanical compression
alone to 7.2% with additional pharmacological prophylaxis (RR 0.84)
and a significant reduction in DVT from 9.7% with anticoagulation
alone to 0.9% with additional mechanical compression (RR 0.17, p
<
0.001; number needed to treat: 12), with no heterogeneity (I2 =
0%). The included studies had insufficient power to demonstrate
an effect on pulmonary embolism. We conclude that the addition of intermittent mechanical leg
compression augments the efficacy of anticoagulation in preventing
DVT in patients undergoing both knee and hip replacement. Further
research on the role of combined modalities in thromboprophylaxis
in joint replacement and in other high-risk situations, such as fracture
of the hip, is warranted.
The aim of this review is to evaluate the current
available literature evidencing on peri-articular hip endoscopy
(the third compartment). A comprehensive approach has been set on
reports dealing with endoscopic surgery for recalcitrant trochanteric
bursitis, snapping hip (or coxa-saltans; external and internal),
gluteus medius and minimus tears and endoscopy (or arthroscopy)
after total hip arthroplasty. This information can be used to trigger
further research, innovation and education in extra-articular hip
endoscopy.
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
Antibiotic prophylaxis is routinely administered during joint replacement surgery and may predispose patients to
We compared 55 consecutive total hip replacements performed on 53 morbidly obese patients with osteoarthritis with a matched group of 55 total hip replacements in 53 non-obese patients. The groups were matched for age, gender, prosthesis type, laterality and preoperative Harris Hip Score. They were followed prospectively for five years and the outcomes were assessed using the Harris Hip Score, the Short-form 36 score and radiological findings. Survival at five years using revision surgery as an endpoint, was 90.9% (95% confidence interval 82.9 to 98.9) for the morbidly obese and 100% for the non-obese patients. The Harris Hip and the Short-form 36 scores were significantly better in the non-obese group (p <
0.001). The morbidly obese patients had a higher rate of complications (22% In light of these inferior results, morbidly obese patients should be advised to lose weight before undergoing a total hip replacement, and counselled regarding the complications. Despite these poorer results, however, the patients have improved function and quality of life.
We compared the medium-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity. The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign. The mean follow-up of the patients with a hybrid THR was ten years and for those with a BHR, nine years. Four patients with a hybrid THR and one with a BHR had died. In each group five were lost to follow-up. The revision rate of the hybrid THRs was 16.7% (9 of 54) and of the BHRs 9.3% (5 of 54) (p = 0.195). Radiographs of a further eight hybrid THRs demonstrated wear and osteolysis, and they await revision (p = 0.008). Of the unrevised BHRs 90% had radiological changes, of which approximately 50% had progressed over the previous four years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.24 mm (0.06 to 3.03). The BHRs recorded superior OHS (p = 0.013), UCLA (p = 0.008), and EuroQol visual analogue scores (p = 0.009). After nine years, patients with BHRs remained more active and had a lower rate of revision than those with hybrid THRs. Both groups demonstrated progressive radiological changes at medium-term follow-up.
This study evaluated the feasibility of using published data from more than one register to define the performance of different hip implants. In order to obtain estimates of performance for specific types of hip system from different register, we analysed data from the annual reports of five national and one Italian regional register. We extracted the number of implants and rates of implant survival at different periods of follow-up. Our aim was to assess whether estimates of cumulative survival rate were comparable with data from registers from different countries, and our conclusion was that such a comparison could only be performed incompletely.
We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all trials involving the use of cross-linked polyethylene in total hip replacement. Eligibility for inclusion in the review included the random allocation of treatments, the use of cross-linked and conventional polyethylene, and radiological wear as an outcome measure. The pooled mean differences were calculated for bedding-in, linear wear rate, three-dimensional linear wear rate, volumetric wear rate and total linear wear. Pooled risk ratios were calculated for radiological osteolysis and revision hip replacement. A search of the literature identified 194 potential studies, of which 12 met the inclusion criteria. All reported a significant reduction in radiological wear for cross-linked polyethylene. The pooled mean differences for linear rate of wear, three-dimensional linear rate of wear, volumetric wear rate and total linear wear were all significantly reduced for cross-linked polyethylene. The risk ratio for radiological osteolysis was 0.40 (95% confidence interval 0.27 to 0.58; I2 = 0%), favouring cross-linked polyethylene. The follow-up was not long enough to show a difference in the need for revision surgery.
In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p <
0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 ( The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years.
Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p <
0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972). There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.
We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements.